HomeMy WebLinkAboutSE202200063 Correspondence 2022-11-01 (5)Date: August 9, 2022
Glenn Ray
Verizon Wireless
1831 Rady Court
Richmond, VA 23222
Subject: Structural Analysis Report
NaIIIIIEC7
TOTALLY COMMITTED.
NB+C Engineering Services
120 Eastshore Drive,
Suite 300
Glen Allen, VA 23059
Carrier Designation: Verizon Wireless — 5G LSub Carrier Add
Verizon Wireless Site Name: Greenbriar Park
Verizon Wireless PSLC Code: 178975
Verizon FUZE Project ID: 16829324
Engineering Firm Designation: NB+C Engineering Services Project Number: 100352
Site Data: 1012 Rio Road East, Charlottesville, VA 22901, Albemarle County
Latitude 38.063050, Longitude-78.464760
70 Foot — Monopole Tower
Dear Glenn Ray,
NB+C Engineering Services is pleased to submit this "Structural Analysis Report" to determine the
structural integrity of the above mentioned tower. Information we received for this analysis includes:
• RF Data Sheet by Verizon Wireless dated July 11, 2022
• Mount Analysis Report by TES, LLC (Smart Tool Project #: 10146603) dated July 14, 2022
• Mount Mapping Report and Photos by TTS Wireless for TES, LLC dated April 7, 2022
• Inspection Report by Hightower Solutions for Clark Nexsen (Site #: 22) dated May 25, 2016
• Communication Pole Design Calculations and Drawings by Valmont (Order #: 301374) dated October
15, 2015
• Construction Drawings by Engineering Concepts, Inc. (Project #: 12130) dated May 6, 2015
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we
have determined the tower stress level for the structure and foundation, under the following load case, to be:
Existing + Proposed Equipment Sufficient Capacity
Note: See Table 1 and Table 2 for the proposed and existing loading, respectively.
The analysis has been performed in accordance with ANSIITIA-222-H standard, 2018 Virginia Construction
Code, and local code requirements based upon a basic wind speed of 110 mph.
All equipment proposed in this report shall be installed in accordance with the attached drawings for the
determined available structural capacity to be effective.
We at NB+C Engineering Services appreciate the opportunity of providing our continuing professional services
to Verizon Wireless. If you have any questions or need further assistance on this or any other projects, please
give us a call.
Structural analysis prepared by: Matthew Shufflebarger, PE _&664*"A_
Respectfully submitted by:
411 M himilml
Erik M. Bowers, PE
Engineering Market Manager
VA License No. 57974
LTI/ ()",
ERIK M. BOWERS 3
Lic. No. 57974
819/2022
v` YONAr. 509
tnxTower Report - version 8.1.1.0
Verizon — Greenbriar Park
70 Ft Monopole Tower Structural Analysis
NB+C ES Project Number 100352
TABLE OF CONTENTS
1) INTRODUCTION
2) ANALYSIS CRITERIA
Table 1 - Proposed Antenna and Cable Information
Table 2 - Existing Antenna and Cable Information
3) ANALYSIS PROCEDURE
3.1) Analysis Method
3.2) Assumptions
4) ANALYSIS RESULTS
Table 3 — Section Capacity (Summary)
Table 4 — Foundation Capacity (Summary)
4.1) Recommendations
5) APPENDIX A
tnxTower Output & Additional Calculations
August 9, 2022
Page 2
tnxTower Report - version 8.1.1.0
Verizon — Greenbrier Park
70 Ft Monopole Tower Structural Analysis
NB+C ES Project Number 100352
1) INTRODUCTION
August 9, 2022
The existing tower is a 70 ft Monopole Tower located in Albemarle County, Virginia. The original tower
manufacturer is Valmont designed in October of 2015.
2) ANALYSIS CRITERIA
Building Code:
TIA-222 Revision:
Risk Category:
Ultimate Wind Speed:
Exposure Category:
Topographic Factor:
Ice Thickness:
Wind Speed with Ice:
Service Wind Speed:
2018 Virginia Construction Code
ANSUTIA-222-H
110 mph
C
1
1.0 in
30 mph
60 mph
Table 1 — Proposed Antenna and Cable Information
Center Number
Mounting Line of Antenna
Level (ft) Elevation Antennas Manufacturer
E
Antenna Model
Page 3
Feed
Carrier Line Size Note
(in)
VI.V
i JI
VVIIIIIIJWFJ
11111 IlV V-VJV-1\JLIIV
62.0
3
Samsung
MT6407-77A w/ Integrated
RRH
60.0
1 3
Samsung
CBRS RRH — RT4401-48A
7.0
58.0
2
Commscope
RHSDC-3315-PF-48
Verizon
58.0
3
Samsung
62/666a RRH ORAN
(RF4439d-25A)
56.0
3
Samsung
135/1313 RRH ORAN
(RF4440d-13A)
Table 2 - Existing Antenna and Cable Information
Center
Number
Mounting
Line
of
Antenna
Antenna Model
Carrier
Feed Line
Note
Level (ft)
Elevation
Antennas
Manufacturer
Size (in)
(ft>
67.0
3
Commscope
SBNHH-1D65C
2
60.0
3
Nokia
UHIC B4 RRH 2x60-4R
2
67.0
Verizon
2
57.0
3
Nokia
UHBA B13 RRH 4x30
reless
Wireless
58.0
2
Commscope
RHSDC-3315-PF-48
(2) 6x12 1
60.0
3
Pipe Mount
Hybrid' F,
Notes:
1) Existing Equipment to remain
2) Equipment to be Removed
tnxTower Report - version 8.1.1.0
Verizon — Greenbrier Park
70 Pt Monopole Tower Structural Analysis
NB+C ES Project Number 100352
3) ANALYSIS PROCEDURE
3.1) Analysis Method
August 9, 2022
Page 4
tnxTower (version 8.1.1.0), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A.
3.2) Assumptions
1) Tower and structures were built in accordance with the manufacturer's specifications.
2) The tower and structures have been maintained in accordance with the manufacturer's
specification.
3) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2.
4) Tower geometry, member sizes and grades, and foundation are based on the Communication
Pole Design Calculations and Drawings by Valmont (Order #: 301374) dated October 15, 2015.
5) Existing tower loading based on the Mount Mapping Report and Photos by TTS Wireless for
TES, LLC dated April 7, 2022.
6) Geotechnical information was not available; the soil is conservatively assumed to be sand with
parameters per ANSI/TIA-222-H Annex F.
This analysis may be affected if any assumptions are not valid or have been made in error. NB+C
Engineering Services should be notified to determine the effect on the structural integrity of the tower.
4) ANALYSIS RESULTS
Table 3 — Section Capacity (Summary)
Section
Elevation (ft)
IL
Component
Type
Size
CriticaIC emenitl
P (K) to*P(K)IowI
Capacity
I Pass / Fail
L1
71 - 30.5
Pole
TP19.738xl1.9994.18751
1
I -3.58
I 657.36
1 29.5
1 Pass
L2
30.5 - 1
Pole
TP25x18.6942x0.25
2
-6.21
1148.89
31.7
Pass
Summary
Pole (1-2)
31.7
Pass
Anchor
Rod
30.5
Pass
Base
Plate
14.5
Pass
RATING =
1 31.7
1 Pass
Table 4 — Foundation Capacity (Summary)
Component I % Capacity I Pass/Fail
Structural Rating 12.9 Pass
Soil Interaction Rating 32.5 Pass
Notes:
1) See additional documentation in "Appendix A— Additional Calculations" for calculations
Structure Rating (max from all components) = 32.5%
4.1) Recommendations
1) The tower has sufficient capacity to carry the existing and proposed loads. No modifications are
required at this time.
tnxTower Report - version 8.1.1.0
Verizon — Greenbriar Park
70 Ft Monopole Tower Structural Analysis
NB+C ES Project Number 100352
APPENDIX A
TNXTOWER OUTPUT & ADDITIONAL CALCULATIONS
August 9, 2022
Page 5
tnxTower Report - version 8.1.1.0
]1.0 R
DESIGNED APPURTENANCE LOADING
S
Ff
$
�
�
8
0
9
z
r
r�
U
Ji
Ji
5
30.5ft
1.0 a
TYPE
ELEVATION
TYPE
ELEVATION
IigNring Rod 5ft4'
]3
CEIRS UT 0148A(VBrrsp)
60
NNH0.5S -ROIaT8w!Jounl Pipe
�)
67
CDRSIRTd0014aA(VBrrsp0
60
21W.rldounl RW(Vedzd)
60
414H0.5S6.5C43131-8w!Jounl Pipe
�)
67
21WX1Jounl Piw(UBnzp,)
60
21WX1JoMt Piw(UBrizp,)
60
NNH0.55fi.5CRMTB W Mw Rw
Me m0
67
MSDG3315-PFd (UB,von)
58
MT6C0]-TIAI nt at AMenre
(ValiprQ
RHSDG3316-PFdB (Ue,von)
58
B2IB66ARF6C390.25A(�)
58
MT6C07-TIN Inlegrated AMenm
(Mnrim0
62
a2IB66ARF61391)-25A(�)
58
a2IBB6ARF603913-25A(�)
58
MRMp]-TIA lnlegrated AMenne
')
62
05013RF4 13A(�)
56
B5B13 RF4M00.13A(�Rrimn)
56
CBRS RT4001d8A(Vedzon)
60
=13RF4M00.13A (�Rrimn)
56
MATERIAL
TOWER DESIGN NOTES
Tower is located in Albemarle County, Virginia.
Tower designed for Exposure C to the TIA-222-H Standard.
Tower designed for a 110 mph basic wind in accordance with the TIA-222-H Standard.
Tower is also designed for a 30 mph basic wind with 1.00 in ice. Ice is considered to increase
in thickness with height.
Deflections are based upon a 60 mph wind.
Tower Risk Category If.
Topographic Category 1 with Crest Height of 0.00 ft
TOWER RATING: 31.7%
I
ALL REACTIONS
AREFACTORED
AXIAL
/97IK�
SHEAR \ MOMENT
1 K ��( ���.., y 25 kip -It
TORQUE 0 kip -It
30 mph WIND-1.0000 in ICE
AXIAL
6ITK
SHEAR \ MOMENT
5 K � ���,,, ` 229 kip-ft
TORQUE 0 kip-ft
REACTIONS - 110 mph WIND
Greenbriar Park
=1'` 120 Eastshore Drive, Suite 300
TOTALLY COMMITTED Glen Allen, VA 23059
iw MM M Semmes Phone: (804) 548-4079
W
TIA-222-H - 110 mph/30 mph 1.0000 in Ice Exposure C
Leg Capacity Leg Compression (K)
Mmtlmum ->
Mmtlmum ->
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I
I I I
I I I
I I I
I I I
I I I
I I I
I I I
I I I
I I
I I I I
I I I I
I I I I
I I I I
Greenbriar Park
TOTALLY COMMITTED
120 Eastshore Drive, Suite 300
Glen Allen, VA 23059
Phone: (804) 548-4079
TIA-222-H - Service - 60 mph
Maximum Values
Deflection (in)
w
Tilt (deg)
Twist (deg)
I I I I
I I I I
I I I I
I I I I
I I I I
I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I
I I I I
I I I I
Greenbriar Park
=7'` 120 Eastshore Drive, Suite 300
TOTALLY COMMITTED Glen Allen, VA 23059
WMMM S.M.. Phone: (804) 548-4079
Round Flat
Feed Line Distribution Chart
1' - 71'
Apo In Face App Out Fem 1I Leg
W
Face A
x
Face B
Face C
Greenbriar Park
=1'` 120 Eastshore Drive, Suite 300
TOTALLY COMMITTED Glen Allen, VA 23059
nelMI S.M.. Phone: (804) 548-4079
Stress Distribution Chart
1' - 71'
> 100%' 90%-100%' 75%-90%' 50%-75%' < 50% Overstress
A
w
Face B
Face C
Greenbriar Park
=1'` 120 Eastshore Drive, Suite 300
TOTALLY COMMITTED Glen Allen, VA 23059
WMMM S.M.. Phone: (804) 548-4079
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
1 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Allen, VA 23059
Phone: (804) 548-4079
Verizon Wireless
MLS
FAX
Tower Input Data
The tower is a monopole.
This tower is designed using the TIA-222-H standard.
The following design criteria apply:
Tower is located in Albemarle County, Virginia.
Tower base elevation above sea level: 451.02 ft.
Basic wind speed of 110 mph.
Risk Category II.
Exposure Category C.
Simplified Topographic Factor Procedure for wind speed-up calculations is used.
Topographic Category: 1.
Crest Height: 0.00 ft.
Nominal ice thickness of 1.0000 in.
Ice thickness is considered to increase with height.
Ice density of 56 pcf.
A wind speed of 30 mph is used in combination with ice.
Temperature drop of 50 'F.
Deflections calculated using a wind speed of 60 mph.
A non -linear (P-delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in pole design is 1.
Tower analysis based on target reliabilities in accordance with Annex S.
Load Modification Factors used: Kes(Fw) = 0.95, K{ ,(ti) = 0.85.
Maximum demand -capacity ratio is: 1.
Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered.
Consider Moments - Legs
Consider Moments - Horizontals
Consider Moments - Diagonals
Use Moment Magnification
Use Code Stress Ratios
Use Code Safety Factors - Guys
Escalate Ice
Always Use Max Kz
Use Special Wind Profile
Include Bolts In Member Capacity
Leg Bolts Are At Top Of Section
Secondary Horizontal Braces Leg
Use Diamond Inner Bracing (4 Sided)
SR Members Have Cut Ends
SR Members Are Concentric
Options
Distribute Leg Loads As Uniform
Assume Legs Pinned
Assume Rigid Index Plate
Use Clear Spans For Wind Area
Use Clear Spans For KIA
Recension Guys To Initial Tension
Bypass Mast Stability Checks
Use Azimuth Dish Coefficients
Project Wind Area of Appurt.
Autocalc Torque Arm Areas
Add IBC oD+W Combination
Sort Capacity Reports By Component
Triangulate Diamond Inner Bracing
Treat Feed Line Bundles As Cylinder
Ignore KL/ry For 60 Deg. Angle Legs
Use ASCE 10 X-Brace Ly Rules
Calculate Redundant Bracing Forces
Ignore Redundant Members in FEA
SR Leg Bolts Resist Compression
All Leg Panels Have Same Allowable
Offset Girt At Foundation
Consider Feed Line Torque
Include Angle Block Shear Check
Use TIA-222-H Bracing Resist, Exemption
Use TIA-222-H Tension Splice Exemption
Poles
Include Shear -Torsion Interaction
Always Use Sub -Critical Flow
Use Top Mounted Sockets
Pole Without Linear Attachments
Pole With Shroud Or No Appurtenances
Outside and Inside Comer Radii Are
Known
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
2 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Al/en, VA 23059
Phone: (804)548-4079
Verizon Wireless
MILS
FAX
Tapered Pole Section Geometry
Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade
Length Length of Diameter Diameter Thickness Radius
Ll 71.00-30.50 40.50 3.50 18 11.9990 19.7380 0.1875 0.7500 A572-65
(65 ksi)
L2 30.50-1.00 33.00 18 18.6942 25.0000 0.2500 1.0000 A572-65
(65 ksi)
Tapered Pole Properties
Section Tip Dia. Area / r C 7/C J 6/Q w IVA
in in, tn4 in in in, in4 in, in
L1 12.1552 7.0293 123.8970 4.1931 6.0955 20.3260 247.9570 3.5153 1.7818 9.503
20.0136 11.6350 561.8485 6.9404 10.0269 56.0341 1124.4364 5.8186 3.1439 16.767
L2 19.6231 14.6355 629.0189 6.5477 9.4967 66.2359 1258.8654 7.3191 2.8502 11.401
25.3471 196391 1519.8824 8.7863 12.7000 119.6758 3041.7647 9.8214 3.9600 15.84
Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weight Molt. Double Angle Double Angle Double Angle
Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt Stitch Bolt
(perface) A, Spacing Spacing Spacing
Diagonals Horizontals Redundonts
ft j12 in in in in
Ll 71.00-30.50 1 1 1
L2 30.50-1.00 1 1 1
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Sector Exclude
Component
Placement Total
Number Start/End
Width or Perimeter
Weight
From
Type
Number
Per Row Position
Diameter
Torque
ft
in in
Ar
Calculation
Safety Line 3/8 C No
Surface At
71.00 - 1.00 1
1 0.000
0.3750
0.22
(CaAa)
0.000
Feed Line/Linear Appurtenances - Entered As Area
Description Face Allow Exclude Component Placement Total C,,Aq Weight
or Shield From Type Number
Leg Torque ft fP/ft Ar
(Verizon Wireless) 1/2" Ice 0.00 0.72
1" Ice 0.00 0.72
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
3 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
I20 Eastshore Drive, Suite 300
Client
Designed by
Glen Allen, PA 23059
Phone: (804) 548-4079
Verizon Wireless
MLS
FAX
Feed Line/Linear Appurtenances Section Areas
Tower
Tower
Face
A,
AF
CAAA
CAAA
weight
Section
Elevation
In Face
Out Face
ft
It,
ft,
it,
ft,
K
LI
71.00-30.50
A
0.000
0.000
0.000
0.000
0.05
B
0.000
0.000
0.000
0.000
0.00
C
0.000
0.000
1.519
0.000
0.01
L2
30.50-1.00
A
0.000
0.000
0 000
0 000
0.04
B
0.000
0.000
0 000
0 000
0.00
C
0.000
0.000
1.106
0 000
001
Feed Line/Linear Appurtenances Section Areas - With Ice
Tower
Tower
Face
Ice
Aa
AF
CAA,
CAA,
weight
Section
Elevation
or
Thickness
In Face
Out Face
ft
Leg
in
ft,
ft,
ft,
ft,
K
Ll
71.00-30.50
A
0.885
0.000
0.000
0.000
0.000
0.05
B
0.000
0.000
0.000
0.000
0.00
C
0.000
0.000
8.689
0.000
0.06
L2
30.50-1.00
A
0.786
0.000
0.000
0.000
0.000
0.04
B
0.000
0.000
0.000
0.000
0.00
C
0.000
0.000
6.329
0.000
0.05
Feed Line Center of Pressure
Section Elevation CPx CPz CPx CPz
Ice Ice
LI 71.00-30.50 0.0000 0.2998 0.0000 0.8712
L2 30.50-1.00 0.0000 0.3009 0.0000 0.9234
Note: For pole sections, center of pressure calculations do not consider feed line shielding.
Shielding Factor Ka
Tower
Feed Line
Description
Feed Line
K.
K.
Section
Record No.
Se ent Elev.
No Ice
Ice
Ll
2
Safety Line 3/8
30.50 - 71.00
1.0000
1.0000
L2
2
Safe Line 3/8
1.00 - 30.50
1.0000
1.0000
Discrete Tower Loads
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
4 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Allen, VA 23059
Phone: (804) 548-4079
Verizon Wireless
MLS
FAX
Description
Face
Offset
Offsets:
Azimuth
Placement
CA,
CAA,
Weight
or
Type
Horz
Adjustment
Front
Side
Leg
Lateral
Vert
ft
°
ft
.1t,
f 2
K
ft
ft
Lightning Rod 5/8x4'
C
None
0.0000
73.00
No Ice
0.25
0.25
0.00
12" Ice
0.66
0.66
0.01
V Ice
0.97
0.97
0.01
rr+
NNH4SS-65C-R3BT8 w/
A
From Face
1.00
0.0000
67.00
No Ice
17.07
10.27
0.27
Mount Pipe
0.00
12" Ice
17.70
11.69
0.38
(Verizon)
0.00
PIce
18.33
12.78
0.51
NNH4SS-65C-R3BT8 w/
B
From Face
1.00
0.0000
67.00
No Ice
17.07
10.27
0.27
Mount Pipe
0.00
12" Ice
17.70
11.69
0.38
(Verizon)
0.00
PIce
18.33
12.78
0.51
NNH4SS-65C-R3BT8 w/
C
From Face
1.00
0.0000
67.00
No Ice
17.07
10.27
0.27
Mount Pipe
0.00
12" Ice
17.70
11.69
0.38
(Verizon)
0.00
PIce
18.33
12.78
0.51
MT6407-77A Integrated
A
From Face
1.00
0.0000
62.00
No Ice
4.70
1.84
0.08
Antenna
0.00
12" Ice
4.99
2.07
0.11
(Verizon)
0.00
PIce
5.28
2.30
0.14
MT6407-77A Integrated
B
From Face
1.00
0.0000
62.00
No Ice
4.70
1.84
0.08
Antenna
0.00
12" Ice
4.99
2.07
0.11
(Verizon)
0.00
V Ice
5.28
2.30
0.14
MT6407-77A Integrated
C
From Face
1.00
0.0000
62.00
No Ice
4.70
1.84
0.08
Antenna
0.00
12" Ice
4.99
2.07
0.11
(Verizon)
0.00
P Ice
5.28
2.30
0.14
B5B13 RF4440D-13A
A
From Face
1.00
0.0000
56.00
No Ice
1.87
L13
0.07
(Verizon)
0.00
12" Ice
2.03
1.27
0.09
0.00
P Ice
2.21
1.41
0.11
B5B13 RF4440D-13A
B
From Face
1.00
0.0000
56.00
No Ice
1.87
1.13
0.07
(Verizon)
0.00
12" Ice
2.03
1.27
0.09
0.00
P Ice
2.21
1.41
0.11
B5B13RF4440D-13A
C
From Face
1.00
0.0000
56.00
No Ice
1.87
1.13
0.07
(Verizon)
0.00
12" Ice
2.03
1.27
0.09
0.00
V Ice
2.21
1.41
0.11
132B66A RF4439D-25A
A
From Face
1.00
0.0000
58.00
No Ice
1.87
1.25
0.07
(Verizon)
0.00
12" Ice
2.03
1.39
0.09
0.00
P Ice
2.21
1.54
0.11
132B66A RF4439D-25A
B
From Face
1.00
0.0000
58.00
No Ice
1.87
1.25
0.07
(Verizon)
0.00
12" Ice
2.03
1.39
0.09
0.00
P Ice
2.21
1.54
0.11
132B66A RF4439D-25A
C
From Face
1.00
0.0000
58.00
No Ice
1.87
1.25
0.07
(Verizon)
0.00
12" Ice
2.03
1.39
0.09
0.00
P Ice
2.21
1.54
0.11
CBRS RT4401-48A
A
From Face
1.00
0.0000
60.00
No Ice
1.00
0.65
0.02
(Verizon)
0.00
12" Ice
1.12
0.76
0.03
0.00
V Ice
1.26
0.88
0.04
CBRS RT4401-48A
B
From Face
1.00
0.0000
60.00
No Ice
1.00
0.65
0.02
(Verizon)
0.00
12"Ice
1.12
0.76
0.03
0.00
P Ice
1.26
0.88
0.04
CBRS RT4401-48A
C
From Face
1.00
0.0000
60.00
No Ice
1.00
0.65
0.02
(Verizon)
0.00
12"Ice
1.12
0.76
0.03
0.00
P Ice
1.26
0.88
0.04
RHSDC-3315-PF-48
A
From Face
1.00
0.0000
58.00
No Ice
3.71
2.19
0.04
(Verizon)
1.00
12"Ice
3.95
2.39
0.07
0.00
P Ice
4.20
2.61
0.11
RHSDC-3315-PF-48
B
From Face
1.00
0.0000
58.00
No Ice
3.71
2.19
0.04
(Verizon)
1.00
12"Ice
3.95
2.39
0.07
0.00
P Ice
4.20
2.61
0.11
21'x2 4" Mount Pipe
A
From Face
0.50
0.0000
60.00
No Ice
4.99
4.99
0.08
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
5 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Allen, VA 23059
Phone: (804) 548-4079
Verizon Wireless
MLS
FAX
Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight
or Type Horz Adjustment Front Side
Leg Lateral
Vert
ft ft ft, ft, K
0.00
I"Ice
9.26
9.26
0.16
21'x2 4" Mount Pipe
B From Face 0.50 0.0000
60.00 No Ice
4.99
4.99
0.08
(Verizon)
0.00
1/2"Ice
7.12
7.12
0.11
0.00
P Ice
9.26
9.26
0.16
21'x2 4" Mount Pipe
C From Face 0.50 0.0000
60.00 No Ice
4.99
4.99
0.08
(Verizon)
0.00
1/2"Ice
7.12
7.12
0.11
0.00
V Ice
9.26
9.26
0.16
Tower Pressures - No Ice
GH=Ltoo
Section
z
Kz
9:
Ac
F
A,
AR
A,z
Leg
CAAA
CAAA
Elevation
a
%
7n
Out
c
Face
Face
e
112
ft2
L171.00-30.50
49.53
1.092
30
54.285
A
0.000
54.285
54.285
100.00
0.000
0.000
B
0.000
54.285
100.00
0.000
0.000
C
0 000
54.285
100.00
1.519
0.000
L230.50-1.00
15.13
0.85
23
55.276
A
0.000
55.276
55.276
100.00
0.000
0.000
B
0.000
55.276
100.00
0.000
0.000
C
1 0.000
1 55.276
100.001
1.1061
0.000
Tower Pressure - With Ice
GH = moo
Section
-
Kz
9:
tz
Ac
F
Ar
Aa
A,,
Leg
C,AA,,
C,AA,,
Elevation
a
%
7n
Out
c
Face
Face
n
ft,
e
L171.00-30.50
49.53
1.092
2
0.8852
60.260
A
0.000
60.260
60.260
100.00
0.000
0.000
B
0.000
60.260
MOM
0.000
0.000
C
0.000
60.260
10000
8.689
0.000
L2 30.50-1.00
15.13
0.85
2
0.7862
59.628
A
0.000
59.628
59.628
10000
0.000
0.000
B
0.000
59.628
10000
0.000
0.000
C
1 0.000
59.628
10000,
6.329
0.000
Tower Pressure - Service
GH = t. too
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
6 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Al/en, VA 23059
Phone: (804) 548-4079
Verizon Wireless
MLS
FAX
Section
-
Ki
q,
Ao
F
AF
AR
Ai,
Leg
CAA
CAAA
Elevation
a
%
in
Out
C
Face
Face
e
ft,
L171.00-30.50
49.53
1.092
8
54.285
A
0.000
54.285
54.285
100.00
0.000
0000
B
0.000
54.285
100.00
0.000
0 000
C
0.000
54.285
100.00
1.519
0.000
L2 30.50-1.00
15.13
0.85
7
55.276
A
0.000
55 276
55.276
100.00
0.000
0.000
B
0.000
55.276
100.00
0.000
0.000
C
0.000
55.276
100,001
1.106
1 0.000
Tower Forces - No Ice - Wind Normal To Face
Section
Add
Self
F
e
CF
q-
DF
DR
Ae
F
w
Oct..
Elevation
Weight
Weight
a
Face
c
Psf
ft
K
K
e
ft,
K
pir
Ll
0.06
1.29
A
1
0.73
30
1
1
54.285
1.30
32.15
C
71.00-30.50
B
1
0.73
1
1
54.285
C
1
0.73
1
1
54.285
L2 30.50-1.00
0.05
1.92
A
1
0.73
23
1
1
55.276
1.04
35.19
C
B
1
0.73
1
1
55.276
C
1
0.73
1
1
55.276
Sum Weight:
0.11
3.21
OTM
77.84
2.34
kip-ft.
Tower Forces - No Ice - Wind 60 To Face
Section
Add
Self
F
e
Ct
q=
Dt
Dk
At
F
w
Oct..
Elevation
Weight
Weight
a
Face
c
Psf
K
K
e
p2
K
pir
Ll
0.06
1.29
A
1
0.73
30
1
1
54.285
1.30
32.15
C
71.00-30.50
B
1
0.73
1
1
54.285
C
1
0.73
1
1
54.285
L2 30.50-1.00
0.05
1.92
A
1
0.73
23
1
1
55.276
1.04
35.19
C
B
1
0.73
1
1
55.276
C
1
0.73
1
1
55.276
Sum Weight:
0.11
3.21
OTM
77.84
2.34
ki -ft
Tower Forces - No Ice - Wind 90 To Face
Section
Add
Self
F
e
CF
q_
DF
DR
:L.
F
w
Oct..
Elevation
Weight
Weight
a
Face
c
Psf
K
K
e
ft,
K
pir
Ll
0.06
1.29
A
1
0.73
30
1
1
54.285
1.30
32.15
C
71.00-30.50
B
1
0.73
1
1
54.255
C
1
0.73
1
1
54.255
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
7 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Al/en, VA 23059
Phone: (804) 548-4079
Verizon Wireless
MLS
FAX
Section
Add
Sef
F
e
CF
q=
DF
DR
AF
F
w
CO..
Elevation
Weight
Weight
a
Face
c
Psf
K
K
e
li2K
pir
L2 30.50-1.00
0.05
1.92
A
1
0.73
23
1
1
55.276
1.04
35.19
C
B
1
0.73
1
1
55.276
C
1
0.73
1
1
55.276
Sum Weight:
0.11
3.21
OTM
77.84
2.34
ki -ft
Tower Forces - With Ice - Wind Normal To Face
Section
Add
Sef
F
e
CF
q=
DF
DR
AF
F
w
CO..
Elevation
Weight
Weight
a
Face
c
Psf
K
K
e
K
PY
Ll
0.12
2.03
A
1
1.2
2
1
1
60.260
0.18
4.36
C
71.00-30.50
B
1
1.2
1
1
60.260
C
1
1.2
1
1
60.260
L2 30.50-1.00
0.09
2.58
A
1
1.2
2
1
1
59.141
0.14
4.60
C
B
1
1.2
1
1
59.141
C
1
1.2
1
1
59.141
Sum Weight:
0.21
4.61
OTM
10.49
0.31
kip-ft.
Tower Forces - With Ice - Wind 60 To Face
Section
Add
Sef
F
e
CF
q=
DF
DR
AF
F
w
CO..
Elevation
Weight
Weight
a
Face
c
Psf
ft
K
K
e
ft,
K
Pif
Ll
0.12
2.03
A
1
1.2
2
1
1
60.260
0.18
4.36
C
71.00-30.50
B
1
1.2
1
1
60.260
C
1
1.2
1
1
60.260
L2 30.50-1.00
0.09
2.58
A
1
1.2
2
1
1
59.141
0.14
4.60
C
B
1
1.2
1
1
59.141
C
1
1.2
1
1
59.141
Sum Weight:
0.21
4.61
OTM
10.49
0.31
ki -ft
Tower Forces - With Ice - Wind 90 To Face
Section
Add
Self
F
e
Ct
q_
DF
DR
AF
F
w
Cal.
Elevation
Weight
Weight
a
Face
c
Psf
K
K
e
fi2
K
pir
Ll
0.12
2.03
A
1
1.2
2
1
1
60.260
0.18
4.36
C
71.00-30.50
1 B
I 1
1 1.2
1
1
60.260
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
8 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Al/en, VA 23059
Phone: (804) 548-4079
Verizon Wireless
MLS
FAX
Section
Add
Self
F
e
CF
q=
DF
Da
AF
F
w
CO..
Elevation
Weight
Weight
a
Face
c
Psf
K
K
e
K
PY
C
1
1.2
1
1
60.260
L2 30.50-1.00
0.09
2.58
A
1
1.2
2
1
1
59.141
0.14
4.60
C
B
1
1.2
1
1
59.141
C
1
1.2
1
1
59.141
Sum Weight:
0.21
4.61
OTM
10.49
0.31
ki -ft
Tower Forces - Service - Wind Normal To Face
Section
Add
Self
F
e
CF
q=
DF
Da
AF
F
w
CO..
Elevation
Weight
Weight
a
Face
c
Psf
ft
K
K
e
p2
K
PIf
Ll
0.06
1.29
A
1
0.73
8
1
1
54.285
0.36
9.01
C
71.00-30.50
B
1
0.73
1
1
54.285
C
1
0.73
1
1
54.285
L2 30.50-1.00
0.05
1.92
A
1
0.73
7
1
1
55.276
0.29
9.86
C
B
1
0.73
1
1
55.276
C
1
0.73
1
1
55.276
Sum Weight:
0.11
3.21
OTM
21.81
0.66
kip-ft.
Tower Forces - Service - Wind 60 To Face
Section
Add
Self
F
e
Ct
q-
Dv
DR
Ae
F
it,
CO..
Elevation
Weight
Weight
a
Face
c
Psf
K
K
e
K
pir
Ll
0.06
1.29
A
1
0.73
8
1
1
54.285
0.36
9.01
C
71.00-30.50
B
1
0.73
1
1
54.285
C
1
0.73
1
1
54.285
L2 30.50-1.00
0.05
1.92
A
1
0.73
7
1
1
55.276
0.29
9.86
C
B
1
0.73
1
1
55.276
C
1
0.73
1
1
55.276
Sum Weight:
0.11
3.21
OTM
21.81
0.66
ki -ft
Tower Forces - Service - Wind 90 To Face
Section
Add
Self
F
Ct
q_
DF
DR
:L.
F
w
Ctrl.
Elevation
Weight
Weight
a
Face
c
Psf
K
K
e
K
pir
Ll
0.061
1.291
A
I 11
0,731
8
1 11
11
54.285
1 0.36
1 9.011
C
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
9 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Allen, VA 23059
Phone: (804) 548-4079
Verizon Wireless
MLS
FAX
Section
Add
Self
F
e
CF
q=
DF
Ds
AF
F
w
CO..
Elevation
Weight
Weight
a
Face
c
Psf
K
K
e
K
pir
71.00-30.50
B
1
0.73
1
1
54.285
C
1
0.73
1
1
54.285
L2 30.50-1.00
0.05
1.92
A
1
0.73
7
1
1
55.276
0.29
9.86
C
B
1
0.73
1
1
55.276
C
1
0,73
1
1
55.276
Sum Weight:
0.11
3.21
OTM
21.81
0.66
kip-ft.
Force Totals
Load
Vertical
Sum of
Sum of
Sum of
Sum of
Sum of Torques
Case
Forces
Forces
Forces
Overturning
Overturning
X
Z
Moments, M.
Moments, M-
K
K
K
ki
ki - t
ki - t
Leg Weight
3.21
Bracing Weight
0.00
Total Member Self -Weight
321
-0.05
-0 04
Total Weight
5.19
-0.05
-0.04
Wind deg -No lee
0.00
-4.64
-221.60
-0.04
0.10
Wind 30 deg - No Ice
2.34
-4.02
-191.92
-112.00
0.04
Wind 60 deg - No Ice
4.06
-2.32
-110.83
-193.95
-0.03
Wind 90 deg - No Ice
4.69
0.00
-0.05
-223.95
-0.10
Wind 120 deg - No Ice
4.06
2.32
110.72
-193.95
-0.13
Wind 150 deg - No Ice
2.34
4.02
191.82
-112.00
-0.14
Wind 180 deg - No Ice
0.00
4.64
221.50
-0.04
-0.10
Wind 210 deg - No Ice
-2.34
4.02
191.82
111.92
-0.04
Wind 240 deg - No Ice
-4.06
2.32
110.72
193.87
0.03
Wind 270 deg - No Ice
-4.69
0.00
-0.05
223.87
0.10
Wind 300 deg - No Ice
-4.06
-2.32
-110.83
193.87
0.13
Wind 330 deg - No Ice
-2.34
-4.02
-191.92
111.92
0.14
Member lee
1.40
Total Weight Ice
8.14
-0.08
-0.10
Wind 0 deg - Ice
0.00
-0.53
-24.04
-0.10
0.01
Wind 30 deg - Ice
0.27
-0.46
-20.83
-12.18
0.00
Wind 60 deg - Ice
0.46
-0.26
-12.06
-21.02
-0.00
Wind 90 deg - Ice
0.53
0.00
-0.08
-24.25
-0.01
Wind 120 deg - Ice
0.46
0.26
11.91
-21.02
-0.01
Wind 150 deg - Ice
0.27
0.46
2068
-12.18
-0.01
Wind 180 deg - Ice
0.00
0.53
23.89
-0.10
-0.01
Wind 210 deg - Ice
-0.27
0.46
2068.
11.97
-0.00
Wind 240 deg - Ice
-0.46
0.26
11.91
20.81
0.00
Wind 270 deg - Ice
-0.53
0.00
-0.08
24.05
0.01
Wind 300 deg - Ice
-0.46
-0.26
-12.06
20.81
0.01
Wind 330 deg - Ice
-0.27
-0.46
-20.83
11.97
0.01
Total Weight
5.18
-0.05
-0.04
Wind 0 deg- Service
0.00
-1.30
-62.15
-0.04
0.03
Wind 30 deg - Service
0.66
-1.13
-53.83
-31.41
0.01
Wind 60 deg - Service
1.14
-0.65
-31.10
-54.38
-0.01
Wind 90 deg - Service
1.31
0.00
-0.06
-62.78
-0.03
Wind 120 deg - Service
1.14
0.65
30.98
-54.38
-0.04
Wind 150 deg - Service
0.66
1.13
53.70
-31.41
-0.04
Wind 180 deg - Service
0.00
1.30
62.02
-0.04
-0.03
Wind 210 deg - Service
-0.66
1.13
53.70
31.33
-0.01
Wind 240 deg - Service
-1.14
0.65
30.98
54.30
0.01
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
10 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Allen, VA 23059
Phone: (804) 548-4079
Verizon Wireless
MLS
FAX
Load
VerticalLFomes
Sum of
Sum of
Sum of
Sum of Torques
Case
Forces
Forces
Overturning
Overturning
Z
Moments, M,
Moments, MKM
K
ki
ki -
Wind 270 deg - Service
1
0.00
-006
6270
0.03
Wind 300 deg - Service
4
-0.65
-31.10
54.30
0.04
Wind 330 de - Service
6
-1.13
-53.83
31.33
0.04
Load Combinations
Comb. Description
No.
1
Dead Only
2
1.2 Dead+1.0
Wind 0 deg - No Ice
3
0.9 Dead+1.0
Wind 0 deg - No Ice
4
1.2 Dead+1.0
Wind 30 deg - No Ice
5
0.9 Dead+1.0
Wind 30 deg - No Ice
6
1.2 Dead+1.0
Wind 60 deg - No Ice
7
0.9 Dead+1.0
Wind 60 deg - No Ice
8
1.2 Dead+1.0
Wind 90 deg - No Ice
9
0.9 Dead+1.0
Wind 90 deg - No Ice
10
1.2 Dead+1.0
Wind 120 deg - No Ice
11
0.9 Dead+1.0
Wind 120 deg - No Ice
12
1.2 Dead+1.0
Wind 150 deg - No Ice
13
0.9 Dead+1.0
Wind 150 deg - No Ice
14
1.2 Dead+1.0
Wind 180 deg - No Ice
15
0.9 Dead+1.0
Wind 180 deg - No Ice
16
1.2 Dead+1.0
Wind 210 deg - No Ice
17
0.9 Dead+1.0
Wind 210 deg - No Ice
18
1.2 Dead+1.0
Wind 240 deg - No Ice
19
0.9 Dead+1.0
Wind 240 deg - No Ice
20
1.2 Dead+1.0
Wind 270 deg - No Ice
21
0.9 Dead+1.0
Wind 270 deg - No Ice
22
1.2 Dead+1.0
Wind 300 deg - No Ice
23
0.9 Dead+1.0
Wind 300 deg - No Ice
24
1.2 Dead+1.0
Wind 330 deg - No Ice
25
0.9 Dead+1.0
Wind 330 deg - No Ice
26
1.2 Dead+1.O
Ice+1.0 Temp
27
1.2 Dead+1.0
Wind 0 deg+1.O Ice+1.0
Temp
28
1.2 Dead+1.0
Wind 30 deg+1.O Ice+1.0
Temp
29
1.2 Dead+1.0
Wind 60 deg+1.O Ice+1.0
Temp
30
1.2 Dead+1.0
Wind 90 deg+1.O Ice+1.0
Temp
31
1.2 Dead+1.0
Wind 120 deg+1.O Ice+1.0
Temp
32
1.2 Dead+1.0
Wind 150 deg+1.O Ice+1.0
Temp
33
1.2 Dead+1.0
Wind 180 deg+1.O Ice+1.0
Temp
34
1.2 Dead+1.0
Wind 210 deg+1.O Ice+1.0
Temp
35
1.2 Dead+1.0
Wind 240 deg+1.O Ice+1.0
Temp
36
1.2 Dead+1.0
Wind 270 deg+1.O Ice+1.0
Temp
37
1.2 Dead+1.0
Wind 300 deg+1.O Ice+1.0
Temp
38
1.2 Dead+1.0
Wind 330 deg+1.O Ice+1.0
Temp
39
Dead+Wind
0 deg - Service
40
Dead+Wind
30 deg- Service
41
Dead+Wind
60 deg- Service
42
Dead+Wind
90 deg - Service
43
Dead+Wind
120 deg - Service
44
Dead+Wind
150 deg - Service
45
Dead+Wind
180 deg - Service
46
Dead+Wind
210 deg - Service
47
Dead+Wind
240 deg - Service
48
Dead+Wind
270 deg - Service
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
11 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Al/en, VA 23059
Phone: (804) 548-4079
Verizon Wireless
MLS
FAX
Comb. Description
No.
49 Dead+Wind 300 deg - Service
50 Dead+Wind 330 des - Service
Maximum Member Forces
Section
No.
Elevation
ft
Component
Type
Condition
Gov.
Load
Comb.
Axial
K
Major Axis
Moment
ki"
Minor Axis
Moment
ktp-ft
Ll
71 - 30.5
Pole
Max Tension
1
0.00
0.00
0.00
Max. Compression
26
-5.87
-0.11
0.14
Max. Mx
8
-3.58
-92.10
0.07
Max. My
2
-3.59
-0.05
91.10
Max. Vy
8
3.61
-92.10
0.07
Max. Vic
2
-3.56
-0.05
91.10
Max. Torque
13
0.13
L2
30.5 - 1
Pole
Max Tension
1
0.00
0.00
0.00
Max. Compression
26
-9.25
-0.1 I
0.09
Max. Mx
8
-6.21
-228.78
0.06
Max. My
2
-6.21
-0.05
226.38
Max. Vy
8
4.69
-228.78
0.06
Max. Vic
2
-4.65
-0.05
226.38
Max. Torque
13
0.13
Maximum Reactions
Location Condition
Gov.
Vertical
Horizontal, X
Horizontal, Z
Load
K
K
K
Comb.
Pole Max. Vert
26
9.25
-0.00
0.00
Max. H.
21
4.66
4.69
0.00
Max. H�
3
4.66
-0.00
4.64
Max. M.
2
226.38
-0.00
4.64
Max. M.
8
228.78
-4.69
0.00
Max. Torsion
13
0.13
-2.34
-4.02
Min. Vert
9
4.66
-4.69
0.00
Min. H,
9
4.66
-4.69
0.00
Min. H,
15
4.66
-0.00
-4.64
Min. Mx
14
-226.25
-0.00
-4.64
Min. M.
20
-228.68
4.69
0.00
Min. Torsion
25
-0.13
2.34
4.02
Tower Mast Reaction Summary
Load Vertical Shear, Shear, Overturning Overturning Torque
Combination Moment, M, Moment, M
K K K ktp-jl ktp-jl kip-ft
Dead Only 5.18 0.00 0.00 -0.05 -0.04 0.00
1.2 Dead+1.0 Wind 0 deg - No 621 0.00 -4.64-226.38 -0.05 0.10
Ice
0.9 Dead+1.0 Wind 0 deg - No 466 0.00 -4.64-225.13 -0.04 0.10
Ice
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
12 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Allen, VA 23059
Phone: (804) 548-4079
Verizon Wireless
MLS
FAX
Load
Vertical
Shea
Shear.
Overt-ing
Overturning
Torque
Combination
Moment, A
Moment, M
K
x
x
ki"
ki"
kiy3t
1.2 Dead+1.0 Wind 30 deg - No
6.21
2.34
-4.02
-196.06
-114.41
0.04
Ice
0.9 Dead+1.0 Wind 30 deg - No
4.66
2.34
-4.02
-194.98
-113.78
0.04
Ice
1.2 Dead+1.0 Wind 60 deg - No
6.21
4.06
-2.32
-113.22
-198.13
-0.03
Ice
0.9 Dead+1.0 Wind 60 deg - No
4.66
4.06
-2.32
-112.59
-197.04
-0.03
Ice
1.2 Dead+1.0 Wind 90 deg - No
6.21
4.69
-0.00
-0.06
-228.78
-0.09
Ice
0.9 Dead+1.0 Wind 90 deg - No
4.66
4.69
-0.00
-0.05
-227.52
-0.10
Ice
1.2 Dead+1.0 Wind 120 deg -
6.21
4.06
2.32
113.09
-198.13
-0.13
No Ice
0.9 Dead+1.0 Wind 120 deg -
4.66
4.06
2.32
112.49
-197.04
-0.13
No Ice
1.2 Dead+1.0 Wind 150 deg -
6.21
2.34
4.02
195.93
-114.41
-0.13
No Ice
0.9 Dead+1.0 Wind 150 deg -
4.66
2.34
4.02
194.88
-113.78
-0.13
No Ice
1.2 Dead+1.0 Wind 180 deg -
6.21
0.00
4.64
226.25
-0.05
-0.10
No Ice
0.9 Dead+1.0 Wind 180 deg -
4.66
0.00
4.64
225.04
-0.04
-0.10
No Ice
1.2 Dead+1.0 Wind 210 deg -
6.21
-2.34
4.02
195.93
114.31
-0.04
No Ice
0.9 Dead+1.0 Wind 210 deg -
4.66
-2.34
4.02
194.88
113.70
-0.04
No Ice
1.2 Dead+1.0 Wind 240 deg -
6.21
-4.06
2.32
113.09
198.03
0.03
No Ice
0.9 Dead+1.0 Wind 240 deg -
4.66
-4.06
2.32
112.49
196.97
0.03
No Ice
1.2 Dead+1.0 Wind 270 deg -
6.21
-4.69
-0.00
-0.06
228.68
0.09
No Ice
0.9 Dead+1.0 Wind 270 deg -
4.66
-4.69
-0.00
-0.05
227.44
0.10
No Ice
1.2 Dead+1.0 Wind 300 deg -
6.21
-4.06
-2.32
-113.22
198.03
0.13
No Ice
0.9 Dead+1.0 Wind 300 deg -
4.66
-4.06
-2.32
-112.59
196.97
0.13
No Ice
1.2 Dead+1.0 Wind 330 deg -
6.21
-2.34
-4.02
-196.06
114.31
0.13
No Ice
0.9 Dead+1.0 Wind 330 deg -
4.66
-2.34
-4.02
-194.98
113.70
0.13
No Ice
1.2 Dead+1.0 Ice+1.0 Temp
9.25
0.00
-0.00
-0.09
-0.11
0.00
1.2 Dead+1.0 Wind 0 deg+1.0
9.25
-0.00
-0.53
-24.84
-0.12
0.01
Ice+1.0 Temp
1.2 Dead+1.0 Wind 30 deg+1.0
9.25
0.27
-0.46
-21.52
-12.58
0.00
Ice+1.0 Temp
1.2 Dead+1.0 Wind 60 deg+1.0
9.25
0.46
-0.26
-12.47
-21.71
-0.00
Ice+1.0 Temp
1.2 Dead+1.0 Wind 90 deg+1.0
9.25
0.53
0.00
-0.09
-25.05
-0.01
Ice+1.0 Temp
1.2 Dead+1.0 Wind 120
9.25
0.46
0.26
12.28
-21.71
-0.01
deg+l.O Ice+1.0 Temp
1.2 Dead+1.0 Wind 150
9.25
0.27
0.46
21.34
-12.58
-0.01
deg+l.O Ice+1.0 Temp
1.2 Dead+1.0 Wind 180
9.25
-0.00
0.53
24.65
-0.12
-0.01
deg+l.O Ice+1.0 Temp
1.2 Dead+1.0 Wind 210
9.25
-0.27
0.46
21.34
12.35
-0.00
deg+l.O Ice+1.0 Temp
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
13 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Allen, VA 23059
Phone: (804) 548-4079
Verizon Wireless
MLS
FAX
Load
Vertical
Shear,
Shear.
Overt-Ing
Overturning
Torque
Combination
Moment, A
Moment, M.
K
K
K
ki"
ki"
ki"
1.2 Dead+1.0 Wind 240
9.25
-0.46
0.26
12.28
21.48
0.00
deg+l.O Im+1.0 Temp
1.2 Dead+1.0 Wind 270
9.25
-0.53
0.00
-0.09
24.82
0.01
deg+l.O Im+1.0 Temp
1.2 Dead+1.0 Wind 300
9.25
-0.46
-0.26
-12.47
21.48
0.01
deg+l.O Im+1.0 Temp
1.2 Dead+1.0 Wind 330
9.25
-0.27
-0.46
-21.52
12.35
0.01
deg+l.O Im+1.0 Temp
Dead+Wind 0 deg- Service
5.18
-0.00
-1.30
-63.25
-0.04
0.03
Dead+Wind 30 deg- Service
5.18
0.66
-1.13
-54.78
-31.98
0.01
Dead+Wind 60 deg- Service
5.18
1.14
-0.65
-31.65
-55.36
-0.01
Dead+Wind 90 deg- Service
5.18
1.31
0.00
-0.05
-63.91
-0.03
Dead+Wind 120 deg- Service
5.18
1.14
0.65
31.54
-55.36
-0.04
Dead+Wind 150 deg- Service
5.18
0.66
1.13
54.68
-31.98
-0.04
Dead+Wind 180 deg- Service
5.18
400
1.30
63.14
-0.04
-0.03
Dead+Wind 210 deg- Service
5.18
-0.66
1.13
54.68
31.89
-0.01
Dead+Wind 240 deg- Service
5.18
-1.14
0.65
31.54
55.27
0.01
Dead+Wind 270 deg- Service
5.18
-1.31
0.00
-0.05
63.83
0.03
Dead+Wind 300 deg- Service
5.18
-1.14
-0.65
-31.65
55.27
0.04
Dead+Wind 330 deg - Service
5.18
466
-1.13
-54.78
31.89
0.04
Solution Summary
Sum of Applied Forces
Sum of Reactions
Load
PX
PY
PZ
PX
PY
PZ
%Error
Comb.
K
K
K
K
K
K
1
0.00
-5.18
0.00
0.00
5.18
0.00
0.000%
2
0.00
-6.21
-4.64
-0.00
6.21
4.64
0.003%
3
0.00
-4.66
-4.64
-0.00
4.66
4.64
0.003%
4
2.34
-6.21
-4.02
-2.34
6.21
4.02
0.003%
5
2.34
-4.66
-4.02
-2.34
4.66
4.02
0.003%
6
4.06
-6.21
-2.32
-4.06
6.21
2.32
0.003%
7
4.06
-4.66
-2.32
-4.06
4.66
2.32
0.003%
8
4.69
-6.21
0.00
-4.69
6.21
0.00
0.003%
9
4.69
-4.66
0.00
-4.69
4.66
0.00
0.003%
10
4.06
-6.21
2.32
-4.06
6.21
-2.32
0.003%
11
4.06
-4.66
2.32
-4.06
4.66
-2.32
0.003%
12
2.34
-6.21
4.02
-2.34
6.21
-4.02
0.003%
13
2.34
-4.66
4.02
-2.34
4.66
-4.02
0.003%
14
0.00
-6.21
4.64
-0.00
6.21
-4.64
0.003%
15
0.00
-4.66
4.64
-0.00
4.66
-4.64
0.003%
16
-2.34
-6.21
4.02
2.34
6.21
-4.02
0.003%
17
-2.34
-4.66
4.02
2.34
4.66
-4.02
0.003%
18
4.06
-6.21
2.32
4.06
6.21
-2.32
0.003%
19
4.06
-4.66
2.32
4.06
4.66
-2.32
0.003%
20
4.69
-6.21
0.00
4.69
6.21
0.00
0.003%
21
4.69
-4.66
0.00
4.69
4.66
0.00
0.003%
22
4.06
-6.21
-2.32
4.06
6.21
2.32
0.003%
23
4.06
-4.66
-2.32
4.06
4.66
2.32
0.003%
24
-2.34
-6.21
-4.02
2.34
6.21
4.02
0.003%
25
-2.34
4.66
-4.02
2.34
4.66
4.02
0.003%
26
0.00
-9.25
0.00
-0.00
9.25
0.00
0.000%
27
0.00
-9.25
-0.53
0.00
9.25
0.53
0.010%
28
0.27
-9.25
-0.46
-0.27
9.25
0.46
0.010%
29
0.46
-9.25
-0.26
-0.46
9.25
0.26
0.010%
30
0.53
-9.25
0.00
-0.53
9.25
-0.00
0.010%
31
0.46
-9.25
0.26
-0.46
9.25
-0.26
0.009%
32
0.27
-9.25
0.46
-0.27
9.25
-0.46
0.009%
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
14 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Allen, VA 23059
Phone: (804) 548-4079
Verizon Wireless
MLS
FAX
Sum of Applied Forces
Sum ojReachons
Load
PX
PY
PZ
PX
PY
PZ
%Error
Comb.
K
K
K
K
K
K
33
0.00
-9.25
0.53
0.00
9.25
-0.53
0.009%
34
-0.27
-9.25
0.46
0.27
9.25
-0.46
0.009%
35
-0.46
-9.25
0.26
0.46
9.25
-0.26
0.009%
36
-0.53
-9.25
0.00
0.53
9.25
-0.00
0.009%
37
-0.46
-9.25
-0.26
0.46
9.25
0.26
0.009%
38
-0.27
-9.25
-0.46
0.27
9.25
0.46
0.009%
39
0.00
-5.18
-1.30
0.00
5.18
1.30
0.003%
40
0.66
-5.18
-1.13
-0.66
5.18
1.13
0.003%
41
1.14
-5.18
-0.65
-1.14
5.18
0.65
0.003%
42
1.31
-5.18
0.00
-1.31
5.18
-0.00
0.003%
43
1.14
-5.18
0.65
-1.14
5.18
-0.65
0.003%
44
0.66
-5.18
1.13
-0.66
5.18
-1.13
0.003%
45
0.00
-5.18
1.30
0.00
5.18
-1.30
0.003%
46
-0.66
-5.18
1.13
0.66
5.18
-1.13
0.003%
47
-1.14
-5.18
0.65
1.14
5.18
-0.65
0.003%
48
-1.31
-5.18
0.00
1.31
5.18
-0.00
0.003%
49
-1.14
-5.18
-0.65
1.14
5.18
0.65
0.003%
50
-0.66
-5.18
-1.13
0.66
5.18
1.13
0.003%
Non -Linear Convergence Results
Load
Converged?
Number
Displacement
Force
Combimlion
o_fCycles
Tolerance
Tolerance
1
Yes
6
0.00000001
0,00000001
2
Yes
12
0.00000001
000007445
3
Yes
12
0.00000001
000006211
4
Yes
12
0.00000001
000008580
5
Yes
12
0.00000001
000007098
6
Yes
12
0.00000001
000008618
7
Yes
12
0.00000001
000007125
8
Yes
12
0.00000001
000007483
9
Yes
12
0.00000001
000006233
10
Yes
12
0.00000001
000007742
11
Yes
12
0.00000001
000006397
12
Yes
12
0.00000001
000009111
13
Yes
12
0.00000001
000007550
14
Yes
12
0.00000001
000007436
15
Yes
12
0.00000001
000006205
16
Yes
12
0.00000001
000008111
17
Yes
12
0.00000001
000006715
18
Yes
12
0.00000001
000008228
19
Yes
12
0.00000001
000006806
20
Yes
12
0.00000001
000007477
21
Yes
12
0.00000001
000006229
22
Yes
12
0.00000001
000009203
23
Yes
12
0.00000001
000007619
24
Yes
12
0.00000001
000007682
25
Yes
12
0.00000001
000006351
26
Yes
6
0.00000001
000000001
27
Yes
9
0.00000001
000007143
28
Yes
9
0.00000001
000007148
29
Yes
9
0.00000001
000007172
30
Yes
9
0.00000001
000007188
31
Yes
9
0.00000001
0.00007092
32
Yes
9
0.00000001
0.00007007
33
Yes
9
0,00000001
0.00006977
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
15 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Al/en, VA 23059
Phone: (804)548-4079
Verizon Wireless
MILS
FAX
34
Yes
9
0,00000001
0.00006935
35
Yes
9
0.00000001
0.00006968
36
Yes
9
0.00000001
000007046
37
Yes
9
0.00000001
000007051
38
Yes
9
0.00000001
0.00007079
39
Yes
11
0.00000001
0.00007183
40
Yes
11
0.00000001
0.00006835
41
Yes
11
0.00000001
000006870
42
Yes
11
0.00000001
0.00007250
43
Yes
11
0.00000001
0.00006849
44
Yes
11
0.00000001
0.00006827
45
Yes
11
0.00000001
0.00007155
46
Yes
11
0.00000001
000006798
47
Yes
11
0.00000001
000006839
48
Yes
11
0.00000001
0.00007231
49
Yes
11
0.00000001
0.00006870
50
Yes
11
0.00000001
0.00006816
Maximum Tower Deflections - Service Wind
Section Elevation Horz. Gov. Tilt Twist
No. Deflection Load
Ll 71 - 30.5 5.892 42 0.6780 0.0014
L2 34 - 1 1.380 42 0.3816 0.0004
Critical Deflections and Radius of Curvature - Service Wind
Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvatwe
73.00
Lightning Rod 5/8x4'
42
5.892
0.6780
0.0014
25861
67.00
NNH4SS-65C-R3BT8 w/ Momt
42
5.320
0.6497
0.0013
25861
Pipe
62.00
MT6407-77A Integrated Antema
42
4.615
0.6138
0.0012
14367
60.00
CBRS RT4401-48A
42
4.338
0.5993
0.0011
11755
58.00
B21B66A RF4439D-25A
42
4.065
0.5845
0.0011
9946
56.00
B51B13 RF444OD-13A
42
3.797
0.5696
0.0010
8620
Maximum Tower Deflections - Design Wind
Section Elevation Horz. Gov. Tilt Twist
No. Deflection Load
Ll 71 - 30.5 21.098
L2 34 - 1 4.941
2.4283 0.0051
1.3668 0.0016
Critical Deflections and Radius of Curvature - Design Wind
tnXTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
16 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Allen, VA 23059
Phone: (804)548-4079
Verizon Wireless
MILS
FAX
Elevation App olenance Gov. Deflection Tilt Twist Radius of
Load Curvature
73.00
Lightning Rod 5/8x4'
8
21.098
2.4283
0.0052
7240
67.00
NNH4SS-65C-R3BT8 w/ Mount
8
19.051
2.3268
0.0047
7240
Pipe
62.00
MT6407-77A Integrated Antenna
8
16.526
2.1985
0.0042
4022
60.00
CBRS RT4401-48A
8
15.534
2.1464
0.0040
3290
58.00
B21B66A RF443913-25A
8
14.557
2.0936
0.0038
2784
56.00
B51B13 RF444OD-13A
8
13.597
2.0401
0.0036
2412
Compression Checks
Pole Design Data
Section
Elevation Size
L
L
K11r A
P.
4p,
Ratio
No.
P.
ft
ft
ft
in,
K
K
4p,
Ll
71-30.5(1) TP19.738x11.999x0.1875
40.50
0.00
0.0 11.2370
-3.58
657.36
0.005
L2
30.5- 1 (2) 7P25x18.6942x0.25
33.00
0.00
0.0 19.6391
-6.21
1148.89
0.005
Pole Bending Design Data
Section
Elevation Size
M.
4 M
Ratio
M,v
4M•
Ratio
No.
M.
M,v
ft
ki"
ki"
4> ,
ki"
ki"
4M
Ll
71-30.5(1) TP19.738x11.999x0.1875
92.10
318.91
0.289
0.00
318.91
0.000
L2
30.5- 1 (2) 7P25x18.6942x0.25
228.78
733.63
0.312
0.00
733.63
0.000
Pole Shear Design Data
Section
Elevation Size
Actual
4 ,
Ratio
Actual
4T
Ratio
No.
V.
V.
T.
T.
ft
K
K
41:
ki"
ki"
4T
Ll
71-30.5(1) TP19.738x11.999xO.I875
3.61
197.21
0.018
0.09
326.10
0.000
L2
30.5- 1 (2) 7P25x18.6942x0.25
4.69
344.67
0.014
0.09
747.06
0.000
Pole Interaction Design Data
Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria
No. P. M. M,v V. T. Stress Stress
ft AP. AM_ AM_, AV AT Ratio Ratio
tnxTower
NB+C Engineering Services,
Job
Greenbriar Park
Page
17 of 17
Project
Date
LLC
100352
14:28:47 08/08/22
120 Eastshore Drive, Suite 300
Client
Designed by
Glen Allen, FA 23059
Phone: (804)548-4079
Verizon Wireless
MILS
FAX
Section
Elevation
Ratio
Ratio
Ratio
Ratio
Ratio
Comb.
Allow. Criteria
No.
P.
-
M,v
V.
T.
Stress
Stress
.fr
OP„
6M
OM
Ov.
6T
Ratio
Ratio
Ll
71 - 30.5 (1)
0.005
0.289
0.000
0.018
0.000
0.295
1.000 1/
4 8 2
L2
30.5 - 1 (2)
0.005
0.312
0.000
0.014
0.000
0.317
1.000 1/
4 8 2
Section Capacity Table
Section
Elevation
Component
Size Critical
P
ePaa„
%
Pass
No.
ftt
Type
Element
K
K
Capacity
Fail
Ll
71-30.5
Pole
TP19.738xll.999x0.1875 1
-3.58
657.36
29.5
Pass
L2
30.5 - 1
Pole
1P25xl8.6942x0.25 2
-6.21
1148.89
31.7
Pass
Summary
Pole (1,2)
31.7
Pass
RATING =
31.7
Pass
Program Version 8.1.1.0 - 6/3/2021 File://nbcllc.com/dfs/ES/Glen Allen/Projects/Wireless/VZWNZW SOVA Mount Analysis (02628)/Greenbriar
ParWStructural/2022 SA/Analysisfrower/Greenbriar Parked
Monopole Base Plate Connection
BUM
Site Name Greenbrier Park
Order #
�QMff!22E=s,on rI H
Grout Considered: No
le, (in) 1
• Moment (kip-k)
228.78
Axial Force (kips) 1
6.21
Shear Force (kips) 1
4.69
Anchor Rod Data
(8) 1-3/4" a bolts (A615-75 N; Fy=75 ksi, Fu=100 ksi) on 31.01" BC
Base Plate Data
35.38" OD x 2.25" Plate (A572-50; Fy=50 ksi, Fu=65 ksi)
Stiffener Data
N/A
Pole Data
25" x 0.2S" 18-sided pole (A572-65; Fy=65 ksi, Fu=80 ksi)
Anchor Rod Summary
(units of kips, kip -in)
Pu t=43.43
OPn_t=142.5 Stress Rating
Vu=0.59
OVn=90.2 30.5%
Mu = n/a
OMn = n/a Pass
Base Plate Summary
Max Stress (ksi): 6.54
Allowable Stress (ksi): 4S
Stress Rating: 14.5%
(Flexural)
Pass
COplate - Version 4.1.2 Analysis Date: 8/8/2022
Drilled Pier Foundation
BU#:
Site Name: Greenbriar Park
Order Number:
TIA-222 Revison: H
Tourer Type: Monopole
um . Uplift
Moment ki -fl
228.78
Axial Force (kips)
6.21
Shear Force (kips)
4.69
iiiiiiiiiiiiiiiiiiiii i"W
Concrete Stren th, Pc:
4 ksi
Reber Strength, F :
I 60 ksi
Tie Yield Strength, F
60 ksi
-fg
De th
20.5 it
Ext. Above Grade
0.5 If
Pier
Section 1
From 0.5'ab we grade
to 20.5' below grade
Pier Diameter
4.5
If
Reber Quantity
16
Reber Size
10
Clear Cover to Ties
4
in
Tie Size
5
Tie Spacing
12
in
Rebar & Pier Ondons
Rmbrddrd Polr mrun.
Belied Pier Innu6
Soil lateral Check Compression Uplift
D,_o (ft from TOC)
1 6.01
-
Soil Safety Factorl
11.98
Max Moment (kip-ft)
1 250.38
Ratingl
11.1%
Soil vertical Check Compression Uplift
Skin Friction (kips)
96.75
End Bearing (kips)
107.35
Weight of Concrete (kips)
60.12
Total Capacity (kips)
204.11
Axial (kips)
66.33
Rating
32.5%
Reinforced Concrete Flexure Compression Uplift
Critical Depth (ft from TOC)
5.96
Critical Moment(kip-ft)
250.38
Critical Moment Capacityl
1938.54
Ratingl
12.9%
Reinforced Concrete Shear Compression Uplift
Critical Depth (ft from TOC)
15.51
Critical Shear (kip)
1 36.21
Critical Shear Capacity
345.38
Ratingl
10.5%
Structural Foundation Ratingl 12.9%
Soil Interaction Ratingl 32.5%
Groundwater Depth N/A # of Layers 2
Apply TIA-222-H Section 15.5:
N/A
Input Effective Depths (else Actual)
Check Shear alongDepth of Pier: v
Utilize Shear -Friction Methodology
Override Critical Depth:
Go to Soil Calculations
Calculated
Calculated
Ultimate Skin
Ult. Gross
Angle of
Ultimate Skin
Top
Thickness
y.,;;
Yc......
Cohesion
Ultimate Skin
Ultimate Skin
Friction Comp
Bearing
SPT Blow
Layer
Bottom (k)
Friction
Friction
Soil Type
(ft)
(k)
(pcf)
(pcf)
(ksf)
Friction Comp
Friction Uplift
Override
Capacity
Count
(degrees)
(ksf)
Override (ksf)
(ksf)
(ksf)
(ksf)
(ksf)
1
0
2.25
2.25
110
150
0
0
(1
0.000
Cohesionless
2
2.25
20.5
18.25
110
150
0
30
0.871
0.871
0.50
0.50
9
10
Cohesionless
Version 5.0.3
ASCE
WERIC N SOCIEW OF CML ENGINEERS
Address:
No Address at This
Location
ASCE 7 Hazards Report
Standard: ASCE/SEI 7-16 Elevation: 450.02 ft (NAVD 88)
Risk Category: II Latitude: 38.06305
Soil Class: D - Default (see Longitude:-78.46476
Section 11.4.3)
a
Wind
Results:
Wind Speed 110 Vmph
10-year MRI 75 Vmph
25-year MRI 83 Vmph
50-year MRI 89 Vmph
100-year MRI 94 Vmph
Data Source: ASCE/SEI 7-16, Fig. 26.5-1 B and Figs. CC.2-1—CC.2-4, and Section 26.5.2
Date Accessed: Mon Aug 08 2022
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI = 700 years).
Site is not in a hurricane -prone region as defined in ASCE/SEI 7-16 Section 26.2
hftps:/Iasce7hazardtool.online/ Page 1 of 3 Mon Aug 08 2022
Wind
Results:
Wind Speed 110 Vmph
10-year MRI 75 Vmph
25-year MRI 83 Vmph
50-year MRI 89 Vmph
100-year MRI 94 Vmph
Data Source: ASCE/SEI 7-16, Fig. 26.5-1 B and Figs. CC.2-1—CC.2-4, and Section 26.5.2
Date Accessed: Mon Aug 08 2022
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI = 700 years).
Site is not in a hurricane -prone region as defined in ASCE/SEI 7-16 Section 26.2
hftps:/Iasce7hazardtool.online/ Page 1 of 3 Mon Aug 08 2022
ASCE
AMERICAN SOCIM OF CIVIL ENGINEERS
Seismic
Site Soil Class:
Results:
Ss
S,
Fa
F
SMS
SM1
SIDS
Seismic Design Category
D - Default (see Section 11.4.3)
0.216
0.058
1.6
2.4
0.346
0.139
0.231
B
0.35 on MCER Response Spectrum
0.30
0.25 t •
0.20 i I.
0.15
0.10
0.05
0
0 2 4 8 10 12 14
Sa(g) vs T(s)
0.22
0.20
0.18
0.16
0.14
0.12
0.10
0.08
0.06
0.04
0.02
MCER Vertical Response Spectrum
Sa (g) vs T(s)
SD1
TL
PGA:
PGA M
F PGA
I :
C, :
0.25
0.20
0.15
0.10
0.05
0
0.14
0.12
...
0.10
0.08
6.06
0.04
0.02
D 0
0.093
12
0.126
0.195
1.548
1
0.733
Design Response Spectrum
14
Se (g) vs T(s)
Design Vertical Response Spectrum
0.5 - 1.5 2.0
Sa(g) vs T(s)
Data Accessed: Mon Aug 08 2022
Date Source:
USGS Seismic Design Maps based on ASCE/SEI 7-16 and ASCE/SEI 7-16 Table 1.5-2. Additional data for
site -specific ground motion procedures in accordance with ASCE/SEI 7-16 Ch. 21 are available from USGS.
https:/Iasce7hazardtool.online/ Page 2 of 3 Mon Aug 08 2022
ASCE
WERQN SOCIEW OF CML ENGINEERS
Ice
Results:
Ice Thickness:
Concurrent Temperature:
Gust Speed
Data Source:
Date Accessed:
1.00 in.
15F
30 mph
Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8
Mon Aug 08 2022
Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys
and gorges may exceed the mapped values.
Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds,
for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain.
Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice
thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may
exceed the mapped values.
The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided "as is" and without warranties of
any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers;
or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from
reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability,
currency, or quality of any data provided herein. Any third -party links provided by this Tool should not be construed as an endorsement,
affiliation, relationship, or sponsorship of such third -party content by or from ASCE.
ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE 7 Hazard Tool.
hftps:/Iasce7hazardtool.online/ Page 3 of 3 Mon Aug 08 2022