Loading...
HomeMy WebLinkAboutSE202000009 Staff Report 2022-11-03OF AI &N �M 1. .r �1RG[N�A County of Albemarle Department of Community Development To: Albemarle County Board of Supervisors From: Megan Nedostup, AICP, Development Process Manager Date: January 6, 2021 Item: SE202000009 Southwood Phase 1: Request for Special Exception to vary the Code of Development of ZMA201800003, Southwood Phase 1, for changes to the garage setbacks in Blocks 5-8 and rear setbacks in Blocks 6-8. Tax Map Parcels: 09000-00-00-001AO Magisterial District: Scottsville School Districts: Cale E.S; Burley M.S.; Monticello H.S. Zoning District: Neighborhood Model District (ZMA201800003) Summary of Request for Special Exception: The applicant is requesting minor changes to the Code of Development (COD) for Southwood Phase 1. This is variation request #1 for this development. Specifically, the applicant is proposing the following changes: • To allow front loaded garages with a setback from either the face of the unit or the porch in Blocks 5-8. • To reduce the rear setback from 5' to 0' in Blocks 6-8 where the lots are adjacent to greenspace/open space or the trail buffer. Staff recommends approval of the special exception request. Please see Attachment B for staff's full analysis. Staff Recommendation: Staff recommends that the Board adopt the attached Resolution (Attachment C) to approve the special exception request, subject to the condition contained therein. Attachments: A — Applicant's request dated December 4, 2020 B — Staff Analysis C — Resolution July 24, 2020 1 1ST REVISION October 13, 2020 1 2ND REVISION November 4, 2020, edited December 4, 2020 July 24, 2020 1 1ST REVISION October 13, 2020 1 2ND REVISION November 4, 2020, edited December 4, 2020 Southwood ZMA 2018-003 Dear Megan: Please accept this request for the following variations to ZMA 2018-003 Southwood Phase 1 Neighborhood Model District Code of Development. Below, you will find the provision of the code, a description of the approved standard, and the reason(s) for the requested variation. Variations to Building Regulations Table 5 page 13 1. Garage Setback regulations in Table 5 on Dade 13 of Code of Development for ZMA 2018-003 Southwood Phase 1 Neighborhood Model District: As approved, the Code of Development provides Garage Setbacks from framework streets in compliance with Zoning Ordinance 4.19 in blocks 3 - 4 and does not allow framework -street -facing garages in any other block (see attachment 1 for the original version of Table 5 as approved). This application seeks a variation to allow framework -street -facing garages in compliance with 4.19 for blocks 5 - 8 in addition to blocks 3 - 4 (see attachments 2A for a map of the area affected by this request). The rezoning originally intended to allow framework -street -facing garages in blocks 3 - 8 and the prohibition of font -load garages for blocks 5 - 8 was an oversight. To allow framework -street -facing, front -load garages would bring blocks 5 - 8 in alignment and equal to the adjacent blocks 3 and 4, as originally intended. Further, to allow framework -street -facing garages in blocks 5 - 8 will allow the following design goals to be fulfilled and enhanced (please see attachment 2B for an example of each): - In blocks 6 - 8. lots are shallow and narrow and back to the green space, preserved slopes, and/or stream buffer of blocks 1 and 2. Front -load garages in these areas will allow units to satisfy parking requirements while providing some yard space by reducing surface parking area. Alley access, which would be required for rear -load garages in blocks 6 - 8, would be detrimental to the green space and trail buffer, again making framework street -facing, front -load garages a preferred option for these lots. - In block 5, lots back to the recreational amenity space. A central tenant of the resident design is that residential units create a sense of protection and enclosure around the recreational amenity. Alleys and surface parking structures required to comply with a relegated parking scheme would contradict the residents' goal of providing back doors with direct access to a safe, vehicle -free play area. In addition to the garage setback requests in blocks 5 - 8, we have clarified the garage setback language from blocks 9 - 12 of Table 5 of the COD which originally stated: "Framework street facing garage openings and/or garage doors are not allowed in this block. All garage access must be side loaded or relegated to the rear of the building" to instead read: "Framework street facing garage openings and/or garage doors are not allowed in this block - all garage access must be side loaded, relegated to the rear of the building, or accessed from a non - framework street or alley." This change is simply intended to clarify the original meaning: that a front -load garage is determined to be such only in relation to a framework street, not in relation to non -framework streets or alleys. This change has been highlighted in attachment 4. We have also clarified the language in Note C of Table 5 of the COD which originally stated: "The wall plane of all street facing garages must be set back a minimum distance of three feed (3') from the primary streetfacing building fagade" to instead read: "The wall plane of all street facing garages must be set back a minimum distance of three feet (3') from the primary street facing building fagade or from the front porch." This change has been highlighted in attachment 4. 2. Rear Setbacks for Blocks 6 - 8 in Table 5 on page 13 of the Code of Development: As approved, the Code of Development provides a minimum rear setback in blocks 6 - 8 of 5 feet (see attachment 1 for the original version of Table 5 as approved). This application seeks a variation to allow no minimum rear setback in blocks 6 - 8 (see attachment 3A for a map of the area affected by this request). This will bring the rear setback for blocks 6 - 8 in alignment with adjacent blocks 3 and 4 and will allow the opportunity to maximize buildable area in lots that typically backup to the stream buffer, flood plain, or preserved slopes. As lots are not allowed within the stream buffer, flood plain, or preserved slopes, these areas will be protected and any grading within a residential lot will not be allowed to disturb these environmental features. Please see attachment 3B for an example of lots and proposed setback request for blocks 6 - 8. Please find attachment 4 for an example of final modifications to Table 5 of page 13 of the Code of Development for ZMA 2018-003 should requests 1 and 2 be granted. Thank you, Whitney McDermott I architect AIA I wmcdermott@brwarchitects.com July 24, 2020 1 1ST REVISION October 13, 2020 1 2ND REVISION November 4, 2020, edited December 4, 2020 C` I 1111111111411 ICI ATTACHMENT 1: ORIGINAL TABLE 5 FROM APPROVED CODE OF DEVELOPMENT formerly ATTACHMENT 1A ATTACHEMENT 1A: ORIGINAL TABLE S FROM APPROVED CODE OF DEVELOPMENT SOUTHWOOD PHASE I -A NEIGHBORHOOD MODEL DISTRICT -CODE OF DEVELOPMENT JULY 8, 2019 REV. JULY 29, 2019 6.0 BUILT FORM REQUIREMENTS BY BLOCK TABLE 5: SMACK + BUILDING REGULATIONS BY BLOCK REQUIREMENT BLOCKS 3 - 4 BLOCKS BLOCKS 6 - 9 GHBORHOOD CENTER SPECIAL AREA 115' measured on both sides horn Hickory Street right-of-way BURDING HEIGHT MIN NO MIN NO MIN NO MIN 2 STORIES 2 STORIES MAX 3STORIES OR 35 3STORIES OR 40 3SMMBOR45' 4SI'ORIES OR 45' 4STORIES OR 50' FRONT SETBACK FRONTS SHALL ORIENT TOWARDS HICKORY MIN 5' 5' 5' 5 Ib MAX 25' 25' 25' I ,A 28" STEPBACKn Mgt NA NA 15' a 15' a 15' e ATBUILDWGHEIGHTOF 40' 40' 3STORIES OR 45 SIDE SETBACK MIN 3' 3' 5' 5 NO MIN MAX NO MAX NO MAX NO MAX NO MAX NO MAX REAR SETBACK MIN NO MIN 5' 5' 5 NO MIN MAX NO MAX NO MAX NO MAX NO MAX NO MAX TRAIL BUFFER SETBACK a MIN NA NA BLOCK56-8'NA 29MW aMIN MAX 9LOCKS9:29MIWNOMAX NOMAX NOMAX GARAGE SETBACKS FRONTACCBSMRV/MAX TO COMPLY WITH 419C/NO MAX FRAMEWORK STREET FACING GARAGE OPENINGS AND/OR GARAGE DOORS ARE NOT ALLOWED W THESE BLOCKS. ALL GARAGE ACCESS MAST BE SIDE LOADED OR RELEGATED TO THE REAR OF THE BMERNG. MAX PORCH AND DECK 4' 4' 4' 4' 9' ENCROACHMENT MAX RAW AND OVERHANG 2' 2' 3' 3' T ENCROACHMENT SINGLE BURDING FOOTPRINT 3,000 5E 3,000 SF 10,000 SF 20,0005E 20,000 SF MAX NON-RESIDENTIAL STREET FACING BURDING LENGTH NO MIN NO MIN NO MIN NO MIN 50' MIN 200' 200' 200' lob 275' MAX 10' 10 10' 10' 19 MIN AIR PASSAGE WIDTH A Up to an additional 22' of front setback may he provided for non-residential and mixed -use buildings for use as a front patio or courtyard and shall not exceed 25% of the length of the front facade. B In Block 11, for buildings over two (2) stories adjacent to the hail buffer, parking and or drive aisles shall be between the building and the bail buffer. _+C The wall plane of all street facing garages must be set back a minimum distance of three feet (T) tom the primary street facing building facade D A stepback is not requked for buildings with a heat setback of at least 15 E Stepbacks apply to non-residential and multifamily residential buildings only. F Coops, other agricultural use structures, and other accessory buildings except for Flexible Use Structures and Accessory Apartments must meet accessory structure setbacks (4.11_2). G Flexible Use Structures as defined in the Code of Development have the same minimum setbacks as the principal buildings With which they share a lot except for rear and side setbacks, which shall be a minimum of T Page 13 of 21 3/5/20201:33 PM July 24, 2020 1 1ST REVISION October 13, 2020 1 2ND REVISION November 4, 2020, edited December 4, 2020 ATTACHMENT 2A: AREA AFFECTED BY REQUESTED VARIATION formerly ATTACHMENT 18 mly TRAIL BUFFER FRONT -LOAD GARAGES REQUESTED TO BE ALLOWED BLOCKS 5,6,7,& 8 PER COD AS APPROVED, FRONT -LOAD GARAGES ALLOWED IN BLOCKS 3,4 IBA R�K 10 h BLOCK9 BSL!�CK 11 P OLD LYNCHBURG ROAD EzkBng Southwood Community no rezoning at this time BLOC! 12 July 24, 2020 1 1ST REVISION October 13, 2020 1 2ND REVISION November 4, 2020, edited December 4, 2020 ATTACHMENT 2B: FRONT -LOAD GARAGE SCENARIOS FRONT -LOAD GARAGE SCENARIOS trai/buffer or green / block 4 sim. blocks 6 & 7sim. front -load gaffe a/lowed er CODras a roved_ 1 f_ranRfoad - - e requested bl ks 5-8 framework street ` root_ 00 garage request ocres \ BLOCK 5 recreational facility or green space DIAGRAM LEGEND P r� FRONT -LOAD GARAGE ❑� RESIDENTIAL UNIT GRAPHIC SCALE 0 40'- 80'-0. 120'- 0. 0. July 24, 2020 1 1ST REVISION October 13, 2020 1 2ND REVISION November 4, 2020, edited December 4, 2020 ATTACHMENT 3A: AREA AFFECTED BY REQUESTED VARIATION formerly ATTACHMENT 28 ��• �� • BnO�fK] PRE$ERVEDSLOPF$ /�j� /,' TRAIL BUFFER "NO MINIMUM" REAR SETBACK REQUESTED TO BE ALLOWED BLOCKS 6,7,&8 PER COD AS APPROVED, "NO MINIMUM" REAR . BLOCK 10 SETBACK: ALLOWED IN BLOCKS 3,4 j /• \ % BLOCKS BIOCKI BLOCK BLOCKS rm.c>a IBIOCKb\ IBLOCKS 1 \BLOCK) •` _•1 1 — " — STREAM BUFFER '` /^ ----------- FLOODPLAIN �• OT�Tffl"Bl � � OLD LYNCHBURG ROAD BL CKK 9 BLOCK I I d L e � EAOng Southwood Community no rezoning at this time BLOCK 12 July 24, 2020 1 1ST REVISION October 13, 2020 1 2ND REVISION November 4, 2020, edited December 4, 2020 ATTACHMENT 3B: "NO MIN." REAR SETBACK SCENARIOS �T Tree buffer and green space BLOCK 3 BLOCK 8 - black4sim. I blacks 6&7sim. DIAGRAM LEGEND: ----- --- --- - -------- ------ - RESIDENTIAL UNIT EXISTING REAR SETBACK OF "NO MIN." PER COD AS REQUESTED REAR SETBACK OF "NO MIN." APPROVED AND AS REQUESTED TO REMAIN EXISTING REAR SETBACK OF 5' PER COD AS APPROVED street EXISTING REAR SETBACK PER COD AS APPROVED AND AS REQUESTED TO REMAIN private alley GRAPHIC SCALE ILOCK 5 j - 0 40'- 80'-0' 120'- 0. 0' July 24, 2020 1 1ST REVISION October 13, 2020 1 2ND REVISION November 4, 2020, edited December 4, 2020 ATTACHMENT 4: MODIFICATIONS TO TABLE 5 AS REQUESTED (CHANGES HIGHLIGHTED) formerly ATTACHMENT 3 6.0 BUILT FORM REQUIREMENTS BY BLOCK TABLE 5: $ETBACK+ BUILDING REGULATIONS BY BLOCK REQUIREMENT NEIGHBORHOOD CENTER SPECIAL AREA BLOCKS 3-4 BLOCK BLOCKS 6-9 BLOCKS I0-12 115' measured on both sides fmm Hickory Street righlof+my BUILDING HEIGHT MIN NO MIN NOMIN NO MIN 2STORIES 2STORIES MAX 3STORIES OR 35' 3STORIES OR 40' 3STORIES OR 45' 4STORIES OR 45 4STORI ES OR 50' FRONTSETBACK FRONTS SHALL ORIENT TOWARDS HICKORY MIN 5' 5' 5' 5' 1U MAX 25' 25' 25' IS,A 28'A STEPBACKD MIN NA NA 15' E 15' E 15' E AT BUILDING HEIGHT OF 40' 40' 3 STORIES OR M' SIDESEIBACK MIN 3' 3' 5' S' NO MIN MAX NO MAX NO MAX NO MAX NO MAX NO MAX REAR SETBACK MIN NO MIN 5' BLOCKS 6 - 8: NO MIN/ NO MAX 5' NO MIN MAX NO MAX NOMM BLOCK 9:5 MIN/NO MAX NO MAX NO MAX TRAIL BUFFER SETBACK a MIN NA NA BLOCKS 6 - 8: NA 20' MIN U MIN MAX BLOCKS 9: 20 MIN/NO MAX NO MAX NO MAX GARAGESETBACK BLOCKS 6- 8: TO COMPLY WITH 4.190/NO MAX FRAMEWORKSTREET FACING GARAGE OPENI NES AND/OR GARAGE DOORS ARE NOT ALLOWED IN FRONT ACCESS MIN/MAX TOCOMRYWRH4.19C/NOMAX TO COMPLY WITH 4A9 C/NO MAX BLOCKS 9: FRAMMORK STREET FACING GARAGE OPENINGS THESE BLOCKS- ALL GARAGE ACCESS MUST BE SIDE LOADED, RELEGATED TO THE REAR OF THE AND/OR GARAGE DOORS ME NOT ALLOWED IN THIS BLOCK -ALL BUILDING, OR ACCESSED FROM A NON -FRAMEWORK STREET OR ALLEY. GARAGE ACCESS MUST BE SIDE LOADED, RELEGATED TO THE REAR OF THE BUILDING, OR ACCESSED FROM A NON -FRAMEWORK STREET OR ALLEY. MAX PORCH AND DECK ENCROACHMENT 4' 4' 4' 4' 9' MA% SAVE AND OVERHANG 2- 2' 3' 3' T ENCROACHMENT SINGLE BUILDING FOOTPRINT 3.000 SF 3,000 SF 10.000 SF 20,000 SF 20,000 SF MAX NON-RESIDENTIAL STREET FACING BUILDING LENGTH NO MIN NOMIN NO MIN NO MIN 50' MIN 200' 200' 200' 200' 275' MAX 10' 10' 10' 10' 10' MIN AIR PASSAGE WIDTH A Up to an additional 22' of from setback may be provided for non-residential and mixed -use buildings for use as a from patio or courtyard and shall not exceed 25%of the length of the front facade. B In Block 11, for buildings over two (2) stories adjacent W the Vail buffer, parking and or drive aisles shall be between the building and the tail buffer. C The wall plane of all "at facing garages must be set back a minimum distance of three feet (3') from the primary street facing building facade or from the front porch. D A stepback is not required for buildings with a front setback of at least 15'. E Stepbacks apply W non-residential and muRifamily residential buildings only. F Coops, other agricultural use structures, and other accessory buildings except for Flexible Use Structures and Accessory Apartments must meet accessory structure setbacks (4.11.2). 6 Flexible Use Structures as defined in the Code of Development have the same minimum setbacks as the principal buildings with which they share a lot except for rear and side setbacks, which shall be a minimum of 3'. ATTACHMENT B — STAFF ANALYSIS STAFF PERSON: Megan Nedostup, AICP, Development Process Manager BOARD OF SUPERVISORS: January 6, 2021 Staff analysis of this special exception request to vary from the approved ZMA Code of Development and Application Plan was conducted pursuant to the following applicable provisions and evaluation criteria contained in County Code §18-8.5.5.3: 8 PLANNED DEVELOPMENT DISTRICTS - GENERALLY 8.5 PROCEDURES FOR PLANNED DEVELOPMENT APPLICATIONS 8.5.5.3 VARIATIONS FROM APPROVED PLANS, CODES, AND STANDARDS OF DEVELOPMENTS a. The director of planning is authorized to grant a variation from the following provisions of an approved plan, code or standard: 1. Minor changes to yard requirements, build -to lines or ranges, maximum structure heights and minimum lot sizes; 2. Changes to the arrangement of buildings and uses shown on the plan, provided that the major elements shown on the plan and their relationships remain the same; c. The director of planning is authorized to grant a variation upon a determination that the variation: (1) is consistent with the goals and objectives of the comprehensive plan; (2) does not increase the approved development density or intensity of development; (3) does not adversely affect the timing and phasing of development of any other development in the zoning district; (4) does not require a special use permit; and (5) is in general accord with the purpose and intent of the approved application. Staff Analysis — Request for Special Exception to Vary: Special Exception request to vary the Code of Development of ZMA201800003, Southwood Phase 1, for changes to the garage setbacks in Blocks 5-8 and rear setbacks in Blocks 6-8. Variation is per County Code §18-8.5.5.3(a)(1)(2). Evaluation criteria per County Code §18-8.5.5.3(c): (1) The requested variation is consistent with the goals and objectives in the Comprehensive Plan. The proposed changes are consistent with the Neighborhood Model District and Neighborhood Model principles. Evaluation criteria met. Garages will be setback from the front fagade or porch of the units. The lots requesting the modification to the rear setback will be located adjacent to open space. (2) The requested Variation would not increase the approved development density or intensity of development. Evaluation criteria met. The density or intensity of development is not increasing. (3) The requested Variation does not adversely affect the timing or phasing of development of any other development in the zoning district. Evaluation criteria met. No change in the timing or phasing of development will occur with these changes. (4) The requested Variation does not require a Special Use Permit. Evaluation criteria met. These changes do not require a special use permit. (5) The requested Variation is in general accord with the purpose and intent of the approved application plan. The proposal will provide additional open space. The total density and non-residential square footage remain the same. The proposal is consistent with the Neighborhood Model District and Neighborhood Model principles and provides additional pedestrian connectivity and open space. Evaluation criteria met. i Additional factors for consideration: A. Please see the application for Variation Request (Attachment A) for the applicant's description and justification. Staff Recommendation — Request for Special Exception: With regards to the findings contained herein, inclusive of the criteria to be considered per County Code §18- 8.5.5.3(c), as well as other additional factors, staff recommends approval of this Special Exception Request, subject to the following condition: 1. All changes to the Code of Development shall be in accordance with the Front -loaded garage scenario, the "No min" rear setback scenario, and the revised Table 5 prepared by BRW Architects entitled "Attachment 2B: Front -load Garage Scenarios"; "Attachment 3B: "No Min." Rear Setback Scenarios" and "Attachment 4: Modifications to Table 5 as requested (changes highlighted)" last revised on December 4, 2020. RESOLUTION TO APPROVE SE202000009 SOUTHWOOD PHASE I NOW BE IT RESOLVED that, upon consideration of the Memorandum prepared in conjunction with the special exception request and the attachments thereto, including staffs supporting analysis, and all of the factors relevant to the special exception in Albemarle County Code §§ 18-8.5.5.3 and 18-33.49, the Albemarle County Board of Supervisors hereby approves SE202000009 Southwood Phase I to vary the Code of Development approved in conjunction with ZMA201800003 Southwood Phase I for changes to the garage setbacks in Blocks 5-8 and rear setbacks in Blocks 6-8, subject to the condition attached hereto. I, Claudette K. Borgersen, do hereby certify that the foregoing writing is a true, correct copy of a Resolution duly adopted by the Board of Supervisors of Albemarle County, Virginia, by a vote of to as recorded below, at a regular meeting held on Clerk, Board of County Supervisors Ave Nay Mr. Gallaway Ms. LaPisto-Kirtley Ms. Mallek Ms. McKee) Ms. Palmer Ms. Price SE202000009 Southwood Phase I Condition 1. All changes to the Code of Development shall be in accordance with the Front -loaded garage scenario, the "No min" rear setback scenario, and the revised Table 5 prepared by BRW Architects entitled "Attachment 2B: Front - load Garage Scenarios"; "Attachment 3B: "No Min." Rear Setback Scenarios" and "Attachment 4: Modifications to Table 5 as requested (changes highlighted)" last revised on December 4, 2020.