HomeMy WebLinkAboutSDP202200056 Plan - Approved 2022-11-04MARCHANT STREET CONTRACTOR OFFICE W
INITIAL SITE PLAN
a
ALBEMARLE COUNTY, VIRGINIA
PROJECT SUMMARY
NAME OF PROJECT: MARCHANTST CONTRACTOR OFFICE
PROJECTADDRESS: NEAR 2002 MARCHANTST
DEVELOPMENT TYPE: BY -RIGHT
PROJECT NARRATIVE: NEW 3-STORY CONTRACTOR'S OFFICE AND STORAGE BUILDING WITH SURFACE
LEVEL PARKING
APPLICANT/OWNER:
CONTACT:
0 MARCHANT LLC
CHRIS LEBLANC
ADDRESS:
1181 FOXVALE LANE
CHARLOTTESVILLE, VA 22902
PHONE:
434-284-1711
EMAIL:
CHRIS@NOLABUILDS.COM
ENGINEER OF RECORD:
CONTACT:
LINE AND GRADE CIVIL ENGINEERING
KENDRA G. MOON, PE
ADDRESS:
1134TH STREET NE; STE 100
CHARLOTTESVILLE, VA 22902
PHONE:
434-262-0169
EMAIL:
KMOON@LINE-GRADE.COM
SOURCE OF SURVEY AND TOPOGRAPHY:
SOURCE: COMMONWEALTH LAND SURVEYING, LLC
SURVEYED 07/14/2022 - FIELD VERIFIED BY KENDRA MOON, PE 07/27/2022
CONTACT: DAVIDJORDAN, LS
ADDRESS: 1484 GREEN BRI ER PLACE
CHARLOTTESVILLE, VA 22901
PHONE: 434-333-2280
EMAIL: DAVE@VACLS.COM
PARCELS
APPROVED
by the Albemarle County
Community Development Department
Date November 4, 2022
File # SDP202200056
Application Type Initial Site Plan
Lead Reviewer: Cameron Langille
DESIGN INFORMATION:
DISTURBANCE AREA: 0.23 AC (9,976 SF)
PROPOSED IMPERVIOUS AREA: 0.12 AC (5,063
SF; 63% OF SITE)
WATERSHED: BOTH MOORES CREEK AND
MEADOW CREEK
WATER SUPPLY RESERVOIR: RAGGED MTN
UTILITY OWNERS:
GAS:
N/A
WATER:
ACSA
STORM SEWER:
N/A
SANITARY SEWER:
ACSA
PARCEL ID:78-21Q
SHEET
LIST TABLE
OWNER:
0 MARCHANT LLC
SHEET
CONTACT:
CHRIS LEBLANC
NUMBER
SHEET TITLE
ZONED:
LIGHT INDUSTRY
C
COVER SHEET
OVERLAYS:
MANAGED STEEP SLOPES
Co. .1
GENERAL CONSTRUCTION NOTES
MAGISTERIAL DISTRICT:
SCOTTSVILLE
CO.2
LEGEND AND SITE CALCULATIONS
PROFFERS:
NONE
LEGAL AREA:
0.185AC (PER SURVEY -GISSTATES 0.21AC)
C1.0
EXISTING CONDITIONS AND DEMOLITION PLAN
C2.0
SITE PLAN
PROPOSED SITE PLAN REQUIREMENTS
ALLOWED OR REQ'D
C3.0
GRADING AND UTILITY PLAN
BUILDING HEIGHT:
6
TOTAL SHEETS
MAXHEIGHTALLOWED=
65 FT
EXISTING BUILDING HEIGHT=
15 FT
PROPOSED BUILDING HEIGHT-
45 FT
SETBACKS AND STEPBACKS
MIN FRONT SETBACK=
MAX FRONT SETBACK=
SIDE AND REAR SETBACK =
PARKING SETBACK=
STEPBACK =
BUILDING FOOTPRINTS:
EXISTING BUILDINGS
PROPOSED BUILDINGS
PARKING REQUIRED:
SEE CO.2
10 FT FROM ROW OR EXTERIOR EDGE OF SW IF SW IS OUTSIDE ROW
NONE
IF THE ABUTTING LOT IS ZONED RESIDENTIAL, RURAL AREAS, OR THE
MONTICELLO HISTORIC DISTRICT: (1) NO PORTION OF ANY STRUCTURE,
EXCLUDING SIGNS, SHALL BE LOCATED CLOSER THAN 50 FEET FROM THE
DISTRICT BOUNDARY; AND (II) NO OFF-STREET PARKING OR LOADING
SPACE SHALL BE LOCATED CLOSER THAN 20 FEET TO THE DISTRICT
BOUNDARY.
10 FT FROM PUBLIC ST RIGHT OF WAY
15 FROM FRONT FOR EACH FLOOR OVER 40 FT OR 3 STORIES
WAREHOUSE 1,352 SF
CONTRACTOR'S OFFICE 3,066 SF
kM
4
PROJECT LOCATION
Opp
O
0 VVV 0PIREUS ROWO�0•
O
\ MARCHANT ST. 0 00 A Q
o C
as
q
0
NORFOLK SOUTHERN 0 RAILROAD--'
e
SUBMITTAL LOG
SUBMISSION
1
DESCRIPTION
INITIAL
RECIPIENT
COMMUNITY
DEVELOPMENT
SUBMITTAL DATE
09/01/2022
W
z
J
W
U_
L_
L-
N0
0.
U Q
Q Z
z 0
J >
Q F Z
U Z:)
(n O
W Q J
LLJ
z LLI
v/ m
J
Q
F_
a
U
Q
LLJ
LLJ
ry
0
DEPARTMENT OF PLANNING AND COMMUNITY DEVELOPMENT DATE
of Dr��
DEPARTMENT OF ENGINEERING DATE o o%/zozz r
U KENDRA G. MOON a
LIC. N0. 0402063650
DEPARTMENT OF ZONING DATE oxaL
APPROVED KGM
FIRE MARSHAL DATE SUBMISSION NO. 1
PROJECT 2205003
T HE W OR K OF
ALBEMARLE COUNTY SERVICE AUTHORITY DATE LINE + GRAD E
VICINITY MAP ; LOCATION MAP N
SCALE: 1" = 4,000' SCALE: 1" = 500' VIRGINIA DEPARTMENT OF HEALTH DATE Como
GENERAL CONSTRUCTION NOTES:
UTI LITI ES:
CONCRETE AND ASPHALT:
1. ALL CONSTRUCTION METHODS AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CURRENT VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD AND
BRIDGE STANDARDS AND SPECIFICATIONS (VDOT RBS&S), VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK, THE RULES AND REGULATIONS
WATER AND SANITARY SEWER CONSTRUCTION SPECIFICATIONS AND STANDARDS FOR THE PLAN APPROVING AUTHORITY AND ANY OTHER APPLICABLE
FEDERAL, STATE, OR LOCAL ORDINANCES, CODES, AND LAWS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL CONDITIONS, MATERIALS, DIMENSIONS LOCATIONS AND EXISTING ELEMENTS TO REMAIN IN
THE FIELD BEFORE PROCEEDINGS WITH ANY WORK. IF CONDITIONS VARY FROM WHAT IS REPRESENTED IN THE DRAWINGS, THE CONTRACTOR SHALL
IMMEDIATELY NOTIFY THE ENGINEER.
3. EXISTING CONSTRUCTION SHOWN IN THESE DRAWINGS SHALL BE USED AS RELATIVE REFERENCES AND ARE TO BE VERIFIED IN THE FIELD BY THE
CONTRACTOR IF DEEMED CRITICAL FOR PROPER EXECUTION OF THE WORK.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DUST CONTROL MEASURES.
5. PROVIDE ADEQUATE PROTECTION FOR THE EXISTING BUILDINGS, BUILDING OCCUPANTS, VEHICLES AND PEDESTRIANS AT ALL TIMES IN ACCORDANCE
WITH OSHA AND ALL APPLICABLE STATE AND LOCAL CODES.
6. MATERIALS AND EQUIPMENT SHALL BE STORED IN APPROVED AREAS TO PREVENT IMPACTS ON VEHICLES AND PEDESTRIANS. CONTRACTOR SHALL BE
FULLY RESPONSIBLE FOR MEASURES TAKEN TO ENSURE VEHICULAR AND PEDESTRIAN SAFETY THROUGH THE ENTIRE DURATION OF THE WORK. SAFETY
IS PARAMOUNT.
7. EQUIPMENT AND MATERIALS SHALL BE STORED IN DESIGNATED AREAS AND SHALL NOT ENCUMBER THE OWNER'S OPERATIONS, SURROUNDING RIGHT
OF WAY, OR ADJOINING GROUNDS.
8. ALL WORK AREAS SHALL BE CLEANED DAILY.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF BUILDINGS ADJACENT TO WORK AREAS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
COSTS OF DAMAGES RESULTING FROM CONSTRUCTION ACTIVITIES.
10. SECTION CUTS AND DETAIL CALLOUTS INDICATED IN THE DRAWINGS ARE TYPICAL FOR THE PROJECT. THEY ARE TO BE CONSIDERED TYPICAL FOR SIMILAR
CONDITIONS AND HAVE NOT BEEN SHOWN EVERYWHERE THEY APPLY.
11. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR JOB SITE SAFETY.
12. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL CONSTRUCTION.
13. SYMBOLS IN THE DRAWINGS ARE NOT TO SCALE.
14. ALL WORK SHALL BE LAID -OUT PRIOR TO INSTALLATION OF NEW WORK BASED ON MEASUREMENT OF EXISTING CONSTRUCTION AND EXISTING
CONSTRUCTION DESIGNATED TO REMAIN AS PART OF THE PROJECT. DO NOT START INSTALLATION OF WORK UNTIL LAY -OUT IS COMPLETE AND POTENTIAL
CONFLICTS HAVE BEEN IDENTIFIED AND ADDRESSED.
15. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO THE EXISTING BUILDINGS AND ADJACENT GROUNDS AND PROPERTY CAUSE BY
THE CARELESSNESS OR NEGLECT OF HIS WORKMEN. DAMAGE TO PORTIONS OF THE PROPERTY NOT SUBJECT TO WORK UNDER THE CONTRACT SHALL BE
REPAIRED TO THE FULL SATISFACTION OF THE OWNER AND ENGINEER, AT THE CONTRACTOR'S EXPENSE.
16. PROTECTION OF THE WORK: PROTECT EFFECTIVELY ALL MATERIALS AND EQUIPMENT DURING THE ENTIRE PERIOD OF CONSTRUCTION. REPLACE
MATERIALS AND EQUIPMENT DAMAGED, LOST OR STOLEN WITHOUT ADDITIONAL COST TO THE OWNER.
17. PROTECT EXISTING MATERIALS DURING INSTALLATION OF TEMPORARY PROTECTION AND CONSTRUCTION. DO NOT DEFACE OR REMOVE EXISTING
MATERIALS IF INTENDED TO STAY. ATTACHMENTS OF TEMPORARY PROTECTION TO EXISTING CONSTRUCTION SHALL BE APPROVED BY THE ENGINEER
PRIOR TO INSTALLATION.
18. OBTAIN ENGINEER REVIEW AND WRITTEN APPROVAL IN THE FORM OF A CONSTRUCTION CHANGE DIRECTIVE OR SUPPLEMENTAL INSTRUCTION BEFORE
MAKING CHANGES OR ADDITIONS TO CONSTRUCTION OR REMOVING MATERIALS THAT WERE INTENDED TO REMAIN.
19. NOTIFY ENGINEER OF VISIBLE CHANGES IN THE INTEGRITY OF MATERIALS OR COMPONENTS WHETHER DUE TO ENVIRONMENTAL CAUSES INCLUDING
BIOLOGICAL ATTACK, UV DEGRADATION, FREEZING OR THAWING OR DUE TO STRUCTURAL DEFECTS INCLUDING CRACKS, MOVEMENT OR DISTORTION. DO
NOT PROCEED WITH WORK IN QUESTION UNTIL DIRECTED BY THE ENGINEER.
20. WHERE MISSING FEATURES ARE INDICATED TO BE REPAIRED OR REPLACED, PROVIDE FEATURES WHOSE DESIGNS ARE BASED ON ACCURATE
DUPLICATIONS RATHER THAN ON CONJECTURAL DESIGNS, SUBJECT TO APPROVAL OF THE ENGINEER.
21. WHERE WORK REQUIRES EXISTING FEATURES TO BE REMOVED, CLEANED AND REUSED, PERFORM THESE OPERATIONS WITHOUT DAMAGE TO THE
MATERIALS THEMSELVES, TO ADJACENT MATERIALS, OR TO THE SUBSTRATE. WHEN CLEANING, MATCH SAMPLES OF EXISTING MATERIALS THAT HAVE
BEEN CLEANED AND IDENTIFIED FOR ACCEPTABLE CLEANING LEVELS. AVOID OVER CLEANING TO PREVENT DAMAGE TO EXISTING MATERIALS DURING
CLEANING.
22. TEMPORARY MATERIALS MAY BE NEW OR USED, BUT MUST BE ADEQUATE IN FOR REQUIRED USAGE, MUST NOT CREATE UNSAFE CONDITIONS AND MUST
NOT VIOLATE REQUIREMENTS OF APPLICABLE CODES AND STANDARDS.
23. CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE FIRE PROTECTION IN THE FORM OF FIRE EXTINGUISHER OR OTHER EFFECTIVE MEANS OF
EXTINGUISHING FIRE, READY FOR INSTANT USE, DISTRIBUTED AROUND THE PROJECT AND IN AND ABOUT TEMPORARY, INFLAMMABLE STRUCTURES
DURING CONSTRUCTION OF WORK. EXISTING FIRE HOSE CONNECTIONS SHALL BE ACCESSIBLE AT ALL TIMES BY FIRE DEPARTMENT PERSONNEL.
MATERIAL SAND DEBRIS SHALL NOT BE STORED IN FRONT OF THE CONNECTION, THUS PREVENTING ACCESS. THE CONTRACTOR SHALL COORDINATE
ACCESS PROCEDURES WITH THE FIRE MARSHALL.
24. GASOLINE AND OTHER FLAMMABLE LIQUIDS SHALL BE STORED AND DISPENSED FROM UL LISTED SAFETY CONTAINERS IN CONFORMANCE WITH THE
NATIONAL BOARD OF FIRE UNDERWRITERS' RECOMMENDATIONS.
25. SUBMITTALS ARE NOT REQUIRED IF CONTRACTOR ELECTS TO USE THE PROPRIETARY PRODUCTS LISTED. SUBMITTALS WILL BE REQUIRED IF CONTRACTOR
WISHES TO USE ALTERNATE PRODUCTS. ALL ALTERNATE PRODUCTS ARE SUBJECT TO REVIEW AND APPROVAL BY THE ENGINEER AND OWNER.
26. CONTRACTOR SHALL CALL MISS UTILITY AT 1-800-552-7001 BEFORE CONSTRUCTION COMMENCES.
27. TREE AND PLANT ROOTS OR BRANCHES THAT MAY INTERFERE WITH THE WORK SHALL BE TRIMMED OR CUT ONLY WITH THE APPROVAL OF THE OWNER
AND ENGINEER. ANY TREES OR PLANTS WHICH ARE SHOWN TO REMAIN THAT DO NOT INTERFERE WITH THE WORK, BUT ARE DAMAGED BY CONTRACTOR
OR HIS SUB -CONTRACTORS, SHALL BE REPLACED BY CONTRACTOR AT NO ADDITIONAL COST.
WORK AREA PROTECTION AND MAINTENANCE:
1. CLEARING AND GRUBBING SHALL BE CONFINED TO THOSE AREAS NEEDED FOR CONSTRUCTION, AND AS SHOWN IN THE DRAWINGS.
2. DISTURBED AREAS BEYOND THE ROADWAY CURB AND WHERE INDICATED ON THE PLANS SHALL RECEIVE TOPSOIL AS NECESSARY AND AS DIRECTED.
SEEDING MIXTURE SHALL BE DETERMINED BY THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK SECTION 3.32
3. CONTRACTOR IS PERMITTED TO WORK IN THE PUBLIC RIGHT-OF-WAY AND ANY TEMPORARY OR PERMANENT EASEMENT SHOWN ON THE PLANS.
HOWEVER, CONTRACTOR SHALL NOTIFY PROPERTY OWNER(S) FORTY-EIGHT (48) HOURS PRIOR TO WORKING ON ANY PRIVATE PROPERTY TO COORDINATE
ACCESS AND TO DETERMINE A STORAGE AREA FOR MATERIALS IF NEEDED. COORDINATION OF ACCESS TO PUBLIC RIGHT-OF-WAY AND STORAGE OF
MATERIALS THEREON SHALL BE COORDINATED WITH THE ENGINEER. CONTRACTOR'S FAILURE TO NOTIFY AND COORDINATE WITH PROPERTY OWNERS
AND/OR THE ENGINEER MAY RESULT IN DELAYS. NO ADDITIONAL COMPENSATION OR TIME FOR PERFORMANCE WILL BE GIVEN FOR ANY SUCH DELAYS.
4. CONTRACTOR SHALL, AT HIS EXPENSE, MAINTAIN THE WORK SITE IN A CLEAN AND ORDERLY APPEARANCE AT ALL TIMES. ALL DEBRIS AND SURPLUS
MATERIAL COLLECTED SHALL BE DISPOSED OF OFF THE WORK SITE BY CONTRACTOR, AT HIS EXPENSE.
5. EXISTING LAWNS, TREES, SHRUBS, FENCES, UTILITIES, CULVERTS, WALLS, WALKS, DRIVEWAYS, POLES, SIGNS, RIGHT-OF-WAY MONUMENTS, MAILBOXES
AND THE LIKE SHALL BE PROTECTED FROM DAMAGE DURING THE WORK. ANY DAMAGE CAUSED TO SUCH ITEMS SHALL BE REPAIRED OR REPLACED BY
CONTRACTOR AT NO ADDITIONAL COST. PROPERTY PINS DISTURBED BY CONTRACTOR THAT ARE NOT SHOWN ON THE PLANS TO BE DISTURBED SHALL BE
RESTORED BY LICENSED SURVEYOR AT THE CONTRACTOR'S EXPENSE.
6. MEASURES TO CONTROL EROSION AND SEDIMENT SHALL BE PROVIDED PURSUANT TO AND IN COMPLIANCE WITH CURRENT FEDERAL, STATE AND LOCAL
REGULATIONS. THE INFORMATION CONTAINED IN THE CONSTRUCTION PLANS AND/OR APPROVAL OF THE PLANS SHALL IN NO WAY RELIEVE THE
CONTRACTOR OR HIS AGENT OF ANY LEGAL RESPONSIBILITY WHICH MAY BE REQUIRED BY THE CODE OF VIRGINIA OR ANY ORDINANCE ENACTED BY THE
COUNTY OF ALBEMARLE. CONTRACTOR SHALL PROVIDE THE NECESSARY DIVERSION DITCHES, DIKES, OR TEMPORARY CULVERTS REQUIRED TO PREVENT
MUD AND DEBRIS FROM BEING WASHED ONTO THE STREETS OR ADJACENT PROPERTY. CONTRACTOR'S VEHICLES SHALL BE KEPT CLEAN TO PREVENT
MUD OR DUST FROM BEING DEPOSITED ON STREETS. NO AREA SHALL BE LEFT DENUDED FOR MORE THAN SEVEN (7) CALENDAR DAYS.
7. CONTRACTOR SHALL CLEAN UP, RESTORE, SEED AND MAINTAIN ALL DISTURBED AREAS IMMEDIATELY UPON COMPLETION OF WORK. TOPSOIL SEED,
FERTILIZER AND MULCH SHALL BE PLACED IN ACCORDANCE WITH COUNTY OF ALBEMARLE STANDARDS ON ALL DISTURBED AREAS. A PERMANENT STAND
OF GRASS ADEQUATE TO PREVENT EROSION SHALL BE ESTABLISHED PRIOR TO FINAL ACCEPTANCE. ALL EROSION AND SEDIMENT CONTROLS SHALL BE
REMOVED WITHIN 30 DAYS AFTER THE PROJECT IS STABILIZED. (MS-18)
8. FOR FURTHER REQUIREMENTS AND DETAILS OF TREE PRESERVATION, PLANTING, EROSION AND SEDIMENT CONTROL, REFER TO THE VIRGINIA EROSION
AND SEDIMENT CONTROL HANDBOOK.
9. AN EROSION AND SEDIMENT CONTROL CERTIFIED RESPONSIBLE LAND DISTURBER (CRLD) IS REQUIRED FOR ALL LAND DISTURBANCE ACTIVITIES.
10. THE CONTRACTOR SHALL PROPERLY INSTALL AND MAINTAIN EROSION AND SEDIMENT CONTROLS FOR THE LIFE OF THE PROJECT; AND ROUTINELY CHECK
CONTROL DEVICES BEFORE, DURING AND AFTER STORM EVENTS.
1. PRIOR TO CONSTRUCTION OR EXCAVATION, THE CONTRACTOR SHALL ASSUME RESPONSIBILITY OF LOCATING ANY AND ALL UNDERGROUND UTILITIES
(PUBLIC OR PRIVATE) THAT MAY EXIST WITHIN OR CROSS THROUGH THE AREA OF CONSTRUCTION WHETHER OR NOT THEY ARE SHOWN ON THE PLANS.
PRIOR TO ANY CONSTRUCTION ACTIVITY, THE CONTRACTOR SHALL CALL 'MISS UTILITY OF VIRGINIA' AT 1-800-552-7001. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR REPAIRING, AT HIS SOLE EXPENSE, ANY EXISTING UTILITY DAMAGED DURING CONSTRUCTION.
2. THE PLAN DOES NOT GUARANTEE THE EXISTENCE, NONEXISTENCE, SIZE, TYPE, LOCATION, ALIGNMENT, OR DEPTH OF ANY OR ALL UNDERGROUND UTILITIES
OR OTHER FACILITIES. WHERE SURFACE FEATURES (MANHOLES, CATCH BASINS, VALVES, ETC.) ARE UNAVAILABLE OR INCONCLUSIVE. INFORMATION SHOWN
MAY BE FROM UTILITY OWNER'S RECORDS AND/OR ELECTRONIC LINE TRACING, THE RELIABILITY OF WHICH IS UNCERTAIN. THE CONTRACTOR SHALL
PERFORM TEST EXCAVATIONS OR OTHER INVESTIGATION AS NECESSARY TO VERIFY LOCATION AND CLEARANCES.
3. WHEN THE WORK CROSSES EXISTING UTILITIES, THE EXISTING UTILITIES SHALL BE ADEQUATELY SUPPORTED AND PROTECTED FROM THE DAMAGE DUE TO
THE WORK. ALL METHODS FOR SUPPORTING AND MAINTAINING THE EXISTING UTILITIES SHALL BE APPROVED BY THE RESPECTIVE UTILITY COMPANY
AND/OR THE ENGINEER. CONTRACTOR SHALL EXERCISE CARE TO INSURE THAT THE GRADE AND ALIGNMENT OF EXISTING UTILITIES ARE MAINTAINED AND
THAT NO JOINTS OR CONNECTIONS ARE DISPLACED. BACKFILL SHALL BE CAREFULLY PLACED AND COMPACTED TO PREVENT FUTURE DAMAGE OR
SETTLEMENT TO EXISTING UTILITIES. ANY UTILITIES REMOVED AS PART OF THE WORK, AND NOT INDICATED TO BE REMOVED OR ABANDONED, SHALL BE
RESTORED USING MATERIALS AND INSTALLATION EQUAL TO THE UTILITY'S STANDARDS.
4. CONTRACTOR SHALL NOTIFY LANDOWNERS, TENANTS AND THE ENGINEER A MINIMUM OF 72 HOURS PRIOR TO THE INTERRUPTION OF ANY SERVICES.
SERVICE INTERRUPTIONS SHALL BE KEPT TO A MINIMUM.
5. CONTRACTOR TO MAKE ANY NECESSARY ADJUSTMENTS TO ALL UTILITY JUNCTION BOXES, VALVE BOXES, MANHOLES, CLEAN -OUTS, AND OTHER GRADE
RELATED ITEMS IN SIDEWALK, ROADWAY, AND/OR ADJACENT AREAS TO MATCH FINISHED GRADE. COSTS ARE TO BE INCLUDED UNDER THE VARIOUS UNIT
BID ITEMS. NO SEPARATE PAYMENT WILL BE MADE.
6. PER THE VIRGINIA DEPARTMENT OF HEALTH WATERWORKS REGULATIONS (PART II, ARTICLE 3, SECTION 12 VAC 5-590 THROUGH 630), ALL BUILDINGS THAT
HAVE THE POSSIBILITY OF CONTAMINATING THE POTABLE WATER DISTRIBUTION SYSTEM (HOSPITALS, INDUSTRIAL SITES, BREWERIES, ETC.) SHALL HAVE A
BACKFLOW PREVENTION DEVICE INSTALLED WITHIN THE FACILITY. THIS DEVICE SHALL MEET SPECIFICATIONS OF THE VIRGINIA UNIFORM STATEWIDE
BUILDING CODE, SHALL BE TESTED IN REGULAR INTERVALS AS REQUIRED, AND TEST RESULTS SHALL BE SUBMITTED TO THE REGULATORY COMPLIANCE
ADMINISTRATOR IN THE DEPARTMENT OF UTILITIES.
7. ALL BUILDINGS THAT MAY PRODUCE WASTES CONTAINING MORE THAN ONE HUNDRED 100 PARTS PER MILLION OF FATS OIL OR GREASE SHALL INSTALL
A GREASE TRAP. THE GREASE TRAP SHALL MEET SPECIFICATIONS OF THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE, MAINTAIN RECORDS OF CLEANING
AND MAINTENANCE, AND BE INSPECTED ON REGULAR INTERVALS BY THE REGULATORY COMPLIANCE ADMINISTRATOR IN THE DEPARTMENT OF UTILITIES.
8. CONTACT THE REGULATORY COMPLIANCE ADMINISTRATOR AT 970-3032 WITH ANY QUESTIONS REGARDING THE GREASE TRAP OR BACKFLOW PREVENTION
DEVICES.
EARTH WORK AND SITE CONDITIONS:
1. EXCEPT AS OTHERWISE SHOWN ON THE PLANS, ALL CUTS AND FILLS SHALL BE NO GREATER THAN 3:1.
2. UNLESS OTHERWISE NOTED ON THE PLANS OR IN THE SPECIFICATIONS, ALL FILL MATERIALS SHALL BE COMPACTED TO 95% OF THEORETICAL MAXIMUM
DENSITY AS DETERMINED BY AASHTO T-99 METHOD A, WITHIN PLUS OR MINUS 2% OF OPTIMUM MOISTURE, FOR THE FULL WIDTH AND THE DEPTH OF THE
FILL.
3. THE CONTRACTOR SHALL ADD, CHANGE, OR RELOCATE EROSION AND SEDIMENT CONTROLS AT THE DIRECTION OF THE COUNTY OF ALBEMARLE E&S
INSPECTOR TO THEIR SATISFACTION AT NO ADDITIONAL COST TO THE OWNER.
4. ALL GRADING AND IMPROVEMENTS TO BE CONFINED TO THE PROJECT AREA UNLESS OTHERWISE INDICATED.
5. PROPOSED GRADES SHALL BE FIELD ADJUSTED TO CONFORM TO THE INTENT OF THE TYPICAL SECTIONS. A SMOOTH GRADE SHALL BE MAINTAINED FROM
THE BASELINE TO THE PROPOSED EDGE OF PAVEMENT OR FACE OF CURB TO PRECLUDE THE FORMING OF FALSE GUTTERS AND/OR PONDING OF WATER ON
ALL PAVED SURFACES.
6. CONTRACTOR SHALL MAINTAIN A SMOOTH GRADE TO THE PROPOSED EDGE OF PAVEMENT OR FACE OF CURB TO PROVIDE POSITIVE DRAINGE ON ALL PAVED
SURFACES. ANY AREAS WHERE WATER IS IMPOUNDED SHALL BE CORRECTED BY CONTRACTOR AT NO ADDITIONAL COST. POSITIVE DRAINAGE OF ALL
ROADWAY AREAS TO THE STORM DRAIN INLETS OR OTHER ACCEPTABLE DRAINAGE CHANNELS AS NOTED ON THE PLANS IS REQUIRED.
7. CONTRACTOR SHALL MAINTAIN EXISTING STREAMS, DITCHES, DRAINAGE STRUCTURES, CULVERT AND FLOWS AT ALL TIMES DURING THE WORK.
CONTRACTOR SHALL PAY FOR ALL PERSONAL INJURY AND PROPERTY DAMAGE WHICH MAY OCCUR AS A RESULT OF FAILING TO MAINTAIN ADEQUATE
DRAINAGE.
8. ALL PIPES, DI'S AND OTHER STRUCTURES SHALL BE INSPECTED BY THE ENGINEER BEFORE BEING BACKFILLED OR BURIED. THE ENGINEER MAY REQUIRE
CONTRACTOR, AT NO ADDITIONAL COST, TO UNCOVER AND RE-COVER SUCH STRUCTURES IF THE HAVE BEEN BACKFILLED OR BURIED WITHOUT SUCH
INSPECTION.
9. ALL STORM CHANNELS, DRAINS, AND SEWER SYSTEMS SHALL BE CLEANED UPON COMPLETION OF THE PROPOSED WORK. SEDIMENT, CHEMICALS, AND/OR
DEBRIS REMOVED FROM THESE SYSTEMS SHALL BE REMOVED AND DISPOSED OF PROPERLY.
MAINTENANCE OF TRAFFIC:
1. TEMPORARY STREET CLOSURE PERMIT REQUIRED FOR CLOSURE OF SIDEWALKS, PARKING SPACES AND ROADWAYS AND IS SUBJECT TO APPROVAL BY THE
COUNTY OF ALBEMARLE TRAFFIC ENGINEER.
2. THE VIRGINIA WORK AREA PROTECTION MANUAL AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) SHALL GOVERN ALL TEMPORARY
TRAFFIC CONTROL OPERATIONS THROUGHOUT CONSTRUCTION OF THIS PROJECT. ADHERENCE TO APPLICABLE PROVISIONS OF THE MANUAL IS REQUIRED
OF THE CONTRACTOR EVEN THOUGH DETAILED REFERENCE TO ALL SUCH PROVISIONS MAY NOT BE CONTAINED IN THE PLANS.
GENERAL NOTES
3. ALL EXISTING RESIDENTIAL AND COMMERCIAL ENTRANCES SHALL BE MAINTAINED AT ALL TIMES, UNLESS OTHERWISE DIRECTED BY THE ENGINEER.
4. NO TEMPORARY PAVEMENT MARKING SHALL BE ALLOWED ON THE FINAL ASPHALT SURFACE COURSE.
5. THE CONTRACTOR SHALL MAINTAIN ALL LANES OF TRAVEL OPEN FROM 6:30 AM TO 9:00 AM AND 3:00 PM TO 5:00 PM UNLESS DEEMED UNNECESSARY BY
THE ENGINEER. SHORT PERIODS OF ONE WAY FLAGGING OPERATIONS MAY BE CONDUCTED OUTSIDE THE HOURS MENTIONED ABOVE.
6. ALL TRAFFIC SIGNALS SHALL BE ADJUSTED AS DEEMED NECESSARY BY THE ENGINEER PRIOR TO ANY TRAFFIC CHANGES.
7. WHEN WORK IN THE EXCAVATION AREA IS DISCONTINUED FOR A SHORT PERIOD OF TIME, AS AT NIGHT, THE CONTRACTOR SHALL BACKFILL THE CUT AREAS
ADJACENT TO THE BUSTING PAVEMENT WITH A 'FILLET OF MATERIAL'. THE FILLET SHALL BE COMPOSED OF THE SAME MATERIAL (EXCAVATION, BORROW,
BASE COURSE, ETC.) ALL COSTS FOR PLACING AND REMOVING THIS FILLET OF MATERIAL SHALL BE INCLUDED IN THE PRICE BID FOR OTHER BID ITEMS OF
WORK ON THIS PROJECT, AND NO ADDITIONAL CHARGE WILL BE ALLOWED.
8. EXISTING SURFACE, AGGREGATE BASE AND SUBBASE MATERIAL WHICH WILL BE DEMOLISHED OR OBLITERATED DURING CONSTRUCTION AND WHICH IS
SUITABLE FOR MAINTENANCE OF TRAFFIC AS DETERMINED BY THE ENGINEER, SHALL BE SALVAGED AND UTILIZED FOR MAINTENANCE OF TRAFFIC PRIOR TO
THE USE OF COMMERCIAL MATERIAL. WHEN NOT SPECIFIED AS A SEPARATE PAY ITEM, THE REMOVAL AND SALVAGING OF EXISTING SURFACES AND
AGGREGATE BASE AND SUBBASE MATERIAL WILL BE MEASURED AND PAID FOR AS REGULAR EXCAVATION IN ACCORDANCE WITH SECTION 303 OF THE VDOT
ROAD AND BRIDGE SPECIFICATIONS.
9. CONSTRUCT ALL INTERSECTIONS AND DRIVEWAYS UNDER TRAFFIC.
10. IF USED, TEMPORARY TRAFFIC BARRIER SERVICE SHALL BE INSTALLED AND REMOVED SO AS NOT TO PRESENT ANY BLUNT END OR HAZARD TO THE
MOTORING PUBLIC.
11. CONTRACTOR SHALL NOTIFY TRANSIT PROVIDERS A MINIMUM OF TWO WEEKS PRIOR TO ANY IMPACT OR DISRUPTION TO REGULAR SERVICE OR STOPS.
12. ALL EXISTING PAVEMENT MARKINGS CONFLICTING WITH PROPOSED CONSTRUCTION PAVEMENT MARKINGS (IF USED) SHALL BE ERADICATED.
13. INSTALLATION AND REMOVAL OF TEMPORARY TRAFFIC CONTROL DEVICES SHALL BE IN ACCORDANCE WITH THE SECTION 6G.25 OF THE WORK AREA
PROTECTION MANUAL.
14. USE APPROPRIATE SIGNS TO SHIFT PEDESTRIAN TRAFFIC AS NEEDED.
15. CONTRACTOR SHALL ASSURE ENDS OF TEMPORARY CONCRETE BARRIER (IF USED) DO NOT OBSTRUCT INTERSECTION SIGHT LINES.
FIRE PREVENTION:
1. SMOKING SHALL ONLY BE ALLOWED IN DESIGNATED SPACES WITH PROPER RECEPTACLES. "NO SMOKING" SIGNS SHALL BE POSTED AT EACH BUILDING SITE
AND WITHIN EACH BUILDING DURING CONSTRUCTION PER VIRGINIA STATEWIDE FIRE PREVENTION CODE.
2. OVERHEAD WIRING OR OTHER OVERHEAD OBSTRUCTIONS SHALL NOT BE LOWER THAN 13 FEET 6 INCHES OVER A PUBLIC STREET PER THE VIRGINIA
STATEWIDE FIRE PREVENTION CODE.
3. CONTRACTOR SHALL ENSURE THAT BUILDING STREET NUMBERS ARE PLAINLY VISIBLE FROM THE FRONTAGE STREET AT ALL TIMES DURING CONSTRUCTION
FOR EMERGENCY RESPONDERS, PER VIRGINIA STATEWIDE FIRE PREVENTION CODE.
4. AN APPROVED WATER SUPPLY FOR FIRE PROTECTION SHALL BE MADE AVAILABLE AS SOON AS COMBUSTIBLE MATERIALS ARRIVE ON SITE. WASTE AND
COMBUSTIBLE DEBRIS SHALL BE REMOVED FROM THE BUILDING AT THE END OF EACH DAY AND DISPOSED OF IN ACCORDANCE WITH VIRGINIA STATEWIDE
FIRE PREVENTION CODE.
5. OPERATIONS INVOLVING THE USE OF CUTTING AND WELDING SHALL BE DONE IN ACCORDANCE WITH CHAPTER 35 OF THE VIRGINIA STATEWIDE FIRE
PREVENTION CODE.
6. FIRE EXTINGUISHERS SHALL BE PROVIDED WITH NOT LESS THAN ONE APPROVED PORTABLE FIRE EXTINGUISHER AT EACH STAIRWAY ON ALL FLOOR LEVELS
WHERE COMBUSTIBLE MATERIALS HAVE ACCUMULATED IN ACCORDANCE WITH THE VIRGINIA STATEWIDE FIRE PREVENTION CODE.
7. VEHICULAR ACCESS FOR FIRE FIGHTING SHALL BE PROVIDED AT ALL CONSTRUCTION AND DEMOLITION SITES AND TO WITHIN 100 FEET OF TEMPORARY OR
PERMANENT FIRE DEPARTMENT CONNECTIONS. VEHICULAR ACCESS SHALL BE CAPABLE OF SUPPORTING FIRE APPARATUS AND VEHICLE LOADING UNDER
ALL WEATHER CONDITIONS IN ACCORDANCE WITH THE VIRGINIA STATEWIDE FIRE PREVENTION CODE.
1. ALL MATERIAL INSIDE FORMS SHALL BE CLEAN AND FREE OF ALL ROCKS AND OTHER LOOSE DEBRIS. SUB -BASE MATERIAL SHALL BE COMPACTED BY
MECHANICAL MEANS.
2. CONCRETE SHALL NOT BE PLACED UNLESS THE AIR TEMPERATURE IS AT LEAST 40 DEGREES FAHRENHEIT (F) IN THE SHADE AND RISING.
3. CONCRETE SHALL NOT BE PLACED UNTIL STEEL DOWELS HAVE BEEN INSTALLED IN EXISTING CONCRETE IN ACCORDANCE WITH COUNTY OF ALBEMARLE
STANDARDS.
4. 1/2 " PREMOLDED EXPANSION JOINT MATERIAL SHALL BE PLACED AT A MAXIMUM OF 30' INTERVALS ON NEW SIDEWALK, CURB, CURB & GUTTER, AT
EACH END OF DRIVEWAY ENTRANCES, AT EACH END OF HANDICAP RAMPS, SOME POINT ON ENTRANCE WALKS AND STEPS ADJUSTMENTS, AND ALONG
BUILDINGS AND WALLS WHERE NEW CONCRETE SIDEWALKS ARE PLACED AGAINST THEM.
5. ALL EXISTING CURBS, CURB & GUTTER, SIDEWALK AND STEPS TO BE REMOVED SHALL BE TAKEN OUT TO THE NEAREST JOINT. DEMOLITION AND
DISPOSAL COST TO BE INCLUDED IN OTHER UNIT BID ITEMS. NO SEPARATE PAYMENT WILL BE MADE FOR THIS WORK.
6. EXISTING ASPHALT CONCRETE PAVEMENT SHALL BE SAW CUT AND REMOVED AS PER THE SPECIFICATIONS. REMOVAL SHALL BE DONE IN SUCH A
MANNER AS TO NOT TEAR, BULGE OR DISPLACE ADJACENT PAVEMENT. EDGES SHALL BE CLEAN AND VERTICAL, ALL CUTS SHALL BE PARALLEL OR
PERPENDICULAR TO THE DIRECTION OF TRAFFIC.
7. DISPOSAL OF ALL EXCESS AND DEMOLITION MATERIAL IS THE RESPONSIBILITY OF THE CONTRACTOR.
I I ONF \ \ \ 1
CENTER OF SSMH
RIM: 388.70 1P /F \ \ \ \
12- BENCHMARK
1" = 10': 0 10 20
GENERAL SURVEY NOTES:
TOPOGRAPHY SOURCE: ACTUAL GROUND SURVEY
BASIS OF DATUM: HORIZONTAL: NAD-83 VIRGINIA SOUTH ZONE (GPS DERIVED)
VERTICAL: NAVD-88 (GPS DERIVED)
BENCHMARKS: (SEE IMAGES ABOVE)
NVA
U
W
z
w
_0
LL
LL
0
N
L.I_
0
0
Q z
crzOf
0 w z
H-
0 -
U) O
J w
W Q J
w p 0
_ LLI
DOV /^ J
Q
z
Q
2
U
Ir-
0
z
EiC
ui
uj
z
z
w
v)
w
0
z
z
0
U
D
z
0
Q
Lu
z
w
0
TH OF�
0�/00022 2�
KENDRA G. MOON a
LIC. N0. 0402063650
-LIONAL S"G
APPROVED KGM
SUBMISSION NI` 1
PROJEC 2205003
THE WORT. OF
I N E + G R A D E
PROPOSED
LEGEND
EXISTING
S
SANITARY CENTERLINE
S
W
WATER CENTERLINE
W
STORM SEWER
GAS
GAS LINE
GAS
UGE
UNDERGROUND POWER
UGE
OOMM
UNDERGROUND COMMUNICATIONS
C:
OVHD
OVERHEAD UTILITY
OUHD
382
CONTOUR LINE
592 —
CURB/CURB AND GUTTER
SPILL CURB WITH TRANSITION AREA
PAVEMENT MARKING LINE
BUILDING LINE
=»
BUILDING OVERHEAD/PROJECTION
WALL
TREELINE
— —
PROPERTY LINE
— —
EASEMENT LINE
— — — — — — — — — — — — — — —
BUILDING SETBACK LINE
— — — — — — — — — — — — — ——
—
ROAD CENTERLINE
CHANNEL CENTERLINE
— —
— — — —
BERM CENTERLINE
LOID
LIMITS OF DISTURBANCE
DRAINAGE DIVIDE
UTILITY POLE
ADA ACCESS PATH AND LANDING
DETECTABLE WARNING STRIP
—�
SIGN
12 4
PARKING/HANDICAP PARKING COUNTER
26 3
ENTRYWAY/INGRESS/EGRESS SYMBOL
100
TREE
0 Q
SHRUB
CONCRETE
BMP
°
RIPRAP
ABBREVIATIONS
AC ACRES
LVC
LENGTH OF VERTICAL CURVE
ADJ ADJUST
MAX
MAXIMUM
APPROX APPROXIMATE
MIN
MINIMUM
BC BACK OF CURB
ME
MATCH EXISTING
BLDG BUILDING
NIC
NOT IN CONTRACT
BM BENCHMARK
N.T.S.
NOT TO SCALE
BVCS BEGIN VERTICAL CURVE STATION
OC
ON CENTER
BVCE BEGIN VERTICAL CURVE ELEVATION
OD
OUTSIDE DIAMETER
BW BOTTOM OF WALL
O/S
OFFSET
CL CENTERLINE
PC
POINT OF CURVATURE
CF CUBIC FEET
PCC
POINT OF COMPOUND CURVATURE
CG CURB AND GUTTER
PI
POINT OF INTERSECTION
CONIC CONCRETE
PRC
POINT OF REVERSE CURVATURE
D OR 0 DELTA ANGLE
PROP
PROPOSED
DIA DIAMETER
PT
POINT OF TANGENCY
EC EDGE OF CONCRETE
PVC
POINT OF VERTICAL CURVATURE/
EG EXISTING GRADE
POLYVINYL CHLORIDE
EL/ELEV ELEVATION
PVI
POINT OF VERTICAL INTERSECTION
EP EDGE OF PAVEMENT
PVT
POINT OF VERTICAL TANGENCY
EVCS END VERTICAL CURVE STATION
R
RADIUS
EVCE END VERTICAL CURVE ELEVATION
ROW
RIGHT-OF-WAY
EX EXISTING
SAN
SANITARY SEWER
FG FINISHED GRADE
SCH
SCHEDULE (PIPE WALL THICKNESS)
FND FOUNDATION
SD
STORM DRAIN
GRVL GRAVEL
SF
SQUARE FEET
HC HANDICAP
SMH
SANITARY MANHOLE
HP HIGH POINT
STA
STATION
ID INSIDE DIAMETER
SW
SIDEWALK
IRR IRRIGATION
TC
TOP OF CURB
INV INVERT
TEMP
TEMPORARY
LAT LATERAL
THT
THROAT
LF LINEAR FEET
TW
TOP OF WALL
LOD LIMITS OF DISTURBANCE
TYP
TYPICAL
LP LOW POINT
WSEL
WATER SURFACE ELEVATION
ITE TRIP GENERATION:
10TH EDITION TRIP GENERATION DATA
WEEKDAY TRAFFIC
TRIP
VEHICLES
AM PEAK HOUR ADJ.
STREET TRAFFIC
PM
PEAK HOUR
ADJ.
STREET TRAFFIC
USE DESCRIPTION ITE CODE UNITS QTY OF UNITS REDUCTION*
PER DAY
% IN % OUT
IN
OUT TOTAL TRIPS
% IN
% OUT
IN
OUT
TOTAL TRIPS
General Office 710 1,000 sf GFA 3.07
30
86% 14%
3
1
4
16%
84%
1
3
4
General Storage 150 1,000 sf GFA 5.63
54
77% 23%
1
0
1
27%
73%
0
1
1
SITE TOTALS =
4
1
1
4
84
5
5
*Note: all land uses in the 800 and 900 series are entitled to a passby trip reduction of 60% if less than 50,000 SF or a 40% reduction if greater than or equal to 50,000 SF.
PARKING TABULATIONS:
CODE REF.
USE
PARKING REQUIRED
REQUIRED RATE
QUANTITY REQUIRED SPACES
4.12.6 Contractor's (construction office, shop, storage) 1 space / employee on -site 10 Employee(s) 10
1 space / facility vehicle 0 Vehicles 0
TOTAL REQUIRED:
TOTAL PROVIDED:
W 0
Z
Uj
az
Z
w
J
t3
W
z
J
LI.J
U_
LL
`L
O
z
O
O
U
Q
J
Q
z
ZD
Ix
Z
J
c�
;
U
J
O
(.3~
U
Z)
LIJ
(n
O
LIJ
Q
J
LIJ
Q
0
oc
z
w
z
—
m
Q
c~n
J
Q
Q
~
z
z
w
=
w
ry
J
Q
TH OF
g000002z ry1
> KENDRA G. MOON a
LIC. No. 0402063650
A
�0� S
'SSIONAL EN_%
I APPROVED KGM 1
SUBMISSION NO. 1
PROJECT 2205003
T H E W 0 R K O F
I N E + G R A D E
COm2
78-2IH
OWNER VIRGINIA PACIFIC INVESTMENTS LLC
2000 MARCHANT STREET
WOOLEN MILLS
PARCEL C
DR 504 0 PG 20
INSTR: 201900004494
ZONED: LIGHT INDUSTRY
USE' MUL TI-FAMIL Y RESIDENTIAL
MARCHANT STREET
PRIVATE 50'
RIGHT -OF -WA Y
DB 5040 PG 24
_s--
N� LOD 9,976SF
TOPOGRAPHIC L IN/ TS - 7111412022
TMP.- 78-2IN
OWNER- VIRGINIA PACIFIC
INVESTMENTS L L C
ZONED: LIGHT INDUSTRY
INSTR: 201900013362
0 EXISTING CONDITIONS AND DEMOLITION PLAN
1" = 10': 0 10 20
EX.
SUILDING
pVH / crrc //W:
EASEMENT
OS 2043 PG
646
MANAGED STEEP SLOPES PER GIS (TYP)
—OH OHE—
®®
wm WM E/ / �f TOPOGRAPHIC LIMITS - 61,312022
3 7 QRCH%NT STRg
PR/VATS 50'
TjRlG T-Q� Y
C s DB4
°
OH
° CAP IF \ I X \
3827'
N2703I' 8"E II.31'
1
WM DEMOLISH EXISTING BUILDING �� I
P/D �07B000-E-02/000 B9..�85AC�
kt / o
S32°//'/B"W 21713' ��--------- f /
LOD 9,976SF — rJ_ —1 /x
l 3
/ o
1
/ J
78-2IP /
OWNER. ALFRED R. SADTLER
2002 PIREUS ROW
WOOLEN MILLS
BLOCK A, LOT 6
DR 4278 PG 469
ZONED: LIGHT INDUSTRY
USE, SINGLE-FAMIL Y RESIDENTIAL
wrrKUXIMA TE L OCA T10/V -
80' CHESAPEAKEAND
OHIO RAILWAY COMPANY
RIGHT -OF -WA Y
DR 27 PG 70
IJ
IF
uj
z
ui
az
Z
u.r
t3
Lu
z
TH OF'®
/ f o%>>/zozz r21
V KENDRA G. MOON 9
Lic. No. 0402066650
A�04, IONAL
APPROVED KGM
SUBMISSION NO. 1
PROJECT 2205003
T H E W 0 R K O F
L I N E + G R A D E
78-2IH
OWNER VIRGINIA PACIFIC INVESTMENTS LLC
2000 MARCHANT STREET
WOOLEN MILLS
PARCEL C
OB 5040 PG 20
INSTR 201900004484
ZONED LIGHT INDUSTRY
USE MLIL TI-FAMIL Y RESIDENTIAL
MARCHANT STREET
PRIVATE 50'
RIGHT -OF -WA Y
DB 5040 FG 24
TM/0: 78-2IN
OWNER VIRGINIA PACIFIC
INVESTMENTS L L C
ZONED LIGHT INDUSTRY
INSTR: 20I8000I3362
0 SITE PLAN
1" = 10': 0 10 20
EX.
BUILDING
20'
PERMANENT
W4 TERL/NE
EASEMENT
DB 204,5 PG
646
MANAGED STEEP SLOPES PER GIS (TYP)
OH OHE—
PP pP PP
/oNE/ y
76 2IP
OWNER. ALFRED B. SAD TLER
2002 PIREUS ROW
WOOLEN MILLS
BLOCK A, LOT 6
08 4278 PG 469
ZONED LIGHT INDUSTRY
USE SINGL E-FA MIL Y RESIDENTIAL
LEGEND
EXISTING ASPHALT
PROPOSED ASPHALT
1
w
Q
r�
sue;
E�j
V, J
TH OF�
0910>12022 1
KENDR4 G. MOON Y
Lic. No. 0402065650
o�P �Q
o�6 �y�v
%�S`SIONAL SNG
APPROVED KGM
SUBMISSION NO. 1
PROJECT 2205003
T H E W 0 R K O F
L I N E + G R A D E
C2m0
78-2IH
OWNER VIRGINIA PACIFIC INVESTMENTS LLC
2000 MARCHANT STREET
WOOLEN MILLS
PARCEL C
DR 504 0 PG 20
INSTR: 201900004494
ZONED: LIGHT INDUSTRY
USE' MUL TI-FAMIL Y RESIDENTIAL
MANAGED STEEP SLOPES PER CIS (TYF)
—OH OHE—
®®WM PP PP OH
� PP
\ WM ONE/ � /
\ i
o PROP. UNDERGROUND ELECTRIC MARCH NT STR�ET /
PR/ATE 50's—
\ \ E/ SSMH
RIM- 3,5970 vCAPSC0 I Y
RlG T-OF-OFcAP sco I I l \ —5 I M
WV /
pNE ( _�', �___r 5- ___� --- ---- --- I I
MARCHANT STREET ,^ \ /�yE/ \ LOD �—_------5=— — — ��s— 1-- \
PRIVATE 50' ` \=��`=—s—�—s NF \ \ 380.a6 M \ \ \
R/GHT-OF-WAY \ I I 1 \
DB 5040 FG 24 _ s—��` \ \ 38,s/ /NV /N = 85' O $ \ OH \ / \sGN
s� V T = 383.53lp ' CAP
s— � � ♦`. PROP 6" SAN LATERAL \
T ♦ w /� 1 WV \ W�LL %
001, LOD ♦' /
s 1 I I \
\ ♦/♦------------�♦ ,! \ j w� �" / W�6 �� 386.59 � N27°3/' 8"E
I
EX.
BUILDING
W
a
T
W
z
383.35 wM
382.34— I w
TT —/
/ a ♦♦ i"� / \ IF /s CONNECT TO EX. / / I I I I I F l U -' —
\ 384.33 WATER METER / ,
s� SHE LL
m \ i"� i� \ /f °... . e '• o .. I I 36 M P WV
V Iq \ s��
`1 383.09:.�it
\ 1 -' I
O
O
386.82 RO Q\ U
382.71 f_
z
�fI '�� \ 1 ?.. �o.-.•. D \ ---- J— 383.54,\ ------------------------— / l---------
385.15
r— PROPOSED / �b �-•L Q lY
J
\ \ 386.02 STORY BUILDING
\ I I c) / z
�------LLJ
-------- --- FFE=397.8 /
s I T U _
z
\ / J /�/� l o
1 - �- � z C�
/NV OUT = 370.39' /NV /N = 370.75' --� <� � ✓ — LU z
m
SSMH /\ c)
/ \ m / / + � J
/ RIM-Q
376.79 20'
PERMANENT I / I / z I� WATERL /NE / f
EASEMENT J
OB 2043 PJG V � ,
I 646
78-2110 / THE I8-D&L Q
OWNER. ALFRED 3. S4DTLER
37/.
2002 PIREUS ROW l \ e
WOOLEN MILLS /
BLOCK A, LOT 6
D5 4278 PG 469
ZONED: LIGHT INDUSTRY
I USE, SINGLE-FAMIL Y RESIDENTIAL
I
/
TMF: 78-2IN /
OWNER.- VIRGINIA PACIFIC /
I INVESTMENTS L L C
ZONED: LIGHT INDUSTRY
INSTR: 201900013362 /
- GRADING AND UTILITY PLAN
1" = 10': 0 10 20
o��40 �
),TH of Dr��
0 000002z r2
U KENDRA G. MOON a
LIC. N0. 0402063650
A�O��sSIONAL
APPROVED KGM
SUBMISSION NO. 1
PROJECT 2205003
T H E W 0 R K O F
L I N E + G R A D E
C3m0