Loading...
HomeMy WebLinkAboutARB201300110 Checklist 2013-08-26SIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business ARE 13 -110, Scott's Ivy Exxon August 29, 2013 REF CHECKLIST ITEM NOTES TYPE X 9. b For internally illuminated signs, channel lettering OK — reface existing panel wall sign (mounted on a raceway or individual letters) is preferred to cabinet signs. X 5. b When channel letters cannot be adequately accommodated, N/A internally illuminated cabinet signs may be considered. X 6 Reader boards are discouraged. None proposed MATERIALS X 4.c Materials used in the sign should complement the building OK — aluminum panel being served by the sign. COLOR X 4.e Color for raceway- mounted channel letters, the raceway N/A shall match the wall color. Sign colors must be harmonious with each other. OK 1" border and text: white Background: red PMS 187 Sign colors must not clash with the site, when viewed in OK daylight and at night. Overly intense color, (such as dayglo or fluorescent None proposed colors), are prohibited. Use of three colors or less (black and white considered as OK-2 colors) Additional colors may be approved if they contribute to the sign balance /unity. SIZE, SCALE, PROPORTION, AND LOCATION REF CHECKLIST ITEM NOTES X 4. b Signs may not exceed the size, height and setback OK — reface requirements as outlined in Section 4.15 of the Albemarle County Zoning Ordinance (unless sign has a variance). X Appendix A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall OK — reface A.A area is a good working proportioning system for placing a sign. X Appendix Color, form, surface pattern, shape, and disposition of OK A.A.4 elements and openings in an architectural design can affect our perception of scale and can impact the appearance of a sign on a building. X 9.d The wall sign's size must coordinate with the architectural OK — reface element's size. The sign should not over -crowd the architectural element, OK the wall, or the sign area. Buildings and building elements should not be used as OK billboards. X 9.a Wall signs must integrate with the building's architecture. OK — reface The sign placement should not obscure architectural OK features or details, (such as cornices, windows, columns, pilasters and paneling). X 9.d An appropriate height for channel letters in a 30" high sign N/A band is 18 ". This allows 6" of unoccupied space above and below the letters. 4" of clear space above, below, and to the sides of a channel letter sign is considered a minimum, with larger clearances required for larger sign bands. REF CHECKLIST ITEM NOTES Degree of visibility, the distance from the Entrance Corridor, and the architectural design of the building /area will determine sign size, placement, and proportions. X 4.d Lettering should be in proportion (font size and typeface style) to the sign and the building. OK Use of three typefaces or less. OK— 1 Additional typefaces may be approved if they contribute to a balanced /legible /unified sign design. N/A X 9. e. iv The width of the outline must be in proportion to the width of the letter. None proposed An outline width of 1/8" has been found to be an appropriate sign dimension. TRADEMARKS, CORPORATE LOGOS AND GRAPHICS X 4.f The ARB may require that the color and scale of standard templates for trademarks, service marks, corporate logos and graphics be modified. None proposed When used, trademarks, service marks, corporate logos and /or graphics should be incorporated as an integral part of the overall sign. X 5.a External (or no) illumination is preferred for approved graphics /logos; X 5.b internal illumination may be considered for approval on a case -by -case basis. LIGHTING X 9. e. i External (or no) illumination is preferred for wall signs. Non - illuminated X 5.f Any internal illumination is considered to contribute to visual clutter and will be limited. REF CHECKLIST ITEM NOTES X 5.c Internal illumination design approval will be evaluated on size, balance, complexity, and distance from the Entrance Corridor. X 9. e. iv The backgrounds of such cabinet signs must be made N/A opaque (zero light transmission). X 5.e External illumination should be shielded and not create N/A glare. All external light sources shall be white. None proposed X 9. ii Sign lighting (external) should be shielded so that it N/A illuminates only face of the sign and does not shine beyond the edge of the sign. X 9. iii Channel letters with translucent faces must have no light None proposed spilling outward from the top, bottom, sides or back. Faces and returns of channel letters shall be opaque when N/A back -lit (halo -lit). X 9. iv Cabinet signs shall have a non - illuminated background, or N/A an opaque (zero light transmission) background. Cabinet signs shall be constructed such that no light spills outward from the top, bottom, sides or back. X 5.g All illumination shall be non - blinking. None proposed X 5.h An exposed light source that forms the body of a sign, None proposed (such as exposed neon signs), shall not be used in the Entrance Corridors. ARB ACTIONS X If LED lighting is proposed the sign drawing must state None proposed The level of illumination provided by the LED lights will not exceed the illumination produced by a single stroke of 30 milliamp (ma) neon. X Red acrylic #2283 has been determined to be an OK — Red PMS 187 proposed REF CHECKLIST ITEM NOTES inappropriate color for signs. Pantone color match for 2283 is 485C. Red #2793 has been approved as an acceptable substitute. Pantone color match for 2793 is 187C. X ARB Visual clutter resulting from adjacency, for example at the N/A Action Hardee's locations, is a reasonable basis for not allowing Memo: illumination of the graphic. 5/7/12