HomeMy WebLinkAboutARB201300107 Checklist 2013-08-21RESUBMITTAL REVIEW CHECKLIST PROJECT # /NAME: ARB 2013 -107, The Market at Mill Creek Sign August 30, 2013 ARB COMMENT NOTES X Please revise the sign drawing to include the Pantone OK — PMS 293 equivalent for the blue background of the pricing panel. X Please revise the sign drawing to include the following OK — Done note: "The refaced cabinet panel shall be opaque, non - illuminated at night; only the text and pricing shall illuminate" X Please revise the sign drawing to include the height and OK — Done width of the proposed LED gas pricing. 13.125" (t) x 32.125" (w) X Are any other panels other than the gas pricing panel to OK — Note on drawing be refaced? If not, include a note on the drawing stating that the gas pricing panel is the only one to be refaced. X Please revise the sign drawing to include the following OK — Notes on drawing notes regarding the LED intensity for the text (REGULAR) and the gas pricing "Regarding the text illumination: The level of illumination provided by the LED lights will not exceed the illumination produced by a single stroke of 30 milliamp (ma) neon. " "Regarding the LED gas pricing: Daytime intensity limited to 70% of maximum intensity; Nighttime intensity limited to 16% of maximum intensity with automatic dimming at dusk. " X $120 ARB review fee not paid Not received yet. Applicant indicated he mailed them 8/29/13 SIGN REVIEW CHECKLIST WITH REFERENCES — Freestanding Signs ARB 2013 -107. The Market at Mill Creek 8 -27 -13 Question: Is the EXXON ID cabinet being refaced? $120 ARB fee not paid Updated: 9 -30 -2010 REF CHECKLIST ITEM NOTES TYPE X 8.a Monument signs are preferred to pole- mounted signs. OK — reface of existing monument Pole signs may be considered if existing site conditions rule out the ability to use a monument sign, and only when the pole is in proportion to the sign cabinet or panel. N/A MATERIALS X 8.b Materials used in both the sign and support structures should be complementary. OK They should also support the aesthetics of the building /complex being served by the sign. OK X 8.b It is preferred that the base material match one of the primary building materials OK — reface unless the sign design represents itself as a freestanding element complementing the building. N/A COLORS X 4.e Colors must be harmonious with each other. Issue: PMS for proposed blue background not p rovided Colors must not clash with other elements on the site, both when viewed in daylight and at night. OK Overly intense color, (such as dayglo or fluorescent colors), are prohibited. OK Use of three colors or less Black and white are colors. OK — 3 proposed Updated: 9 -30 -2010 Updated: 9 -30 -2010 REF CHECKLIST ITEM NOTES Additional colors may be approved if they contribute to a balanced /unified sign design. X 9.c For raceway- mounted channel letters, raceways shall match N/A the wall color. LANDSCAPING X 8.d Use ground cover, shrubs and /or trees to integrate freestanding N/A — reface signs into the overall site landscape_ Use plants from the Albemarle County Recommended Plants N/A List. SCALE AND SIZE X 4.b Signs may not exceed the size, height and setback OK — per S. Wright 8 -22 -13 requirements as outlined in Section 4.15 of the Albemarle County Zoning Ordinance (unless the sign has received a variance). X 8.c The structure of a monument sign shall not overwhelm the OK — reface sign. The structure and the sign that it supports must be in proportion to each other. SIGN LETTERING AND TYPEFACE X 4.d Lettering should be in proportion (font size and typeface style) Issue: Height and width of LED gas pricing not to the sign and the building. indicated on the sign drawing Use of three typefaces or less. OK— 1 Additional typefaces may be approved if they contribute to a balanced, legible, unified sign design. X 8.e.iv If outlines of letters are proposed, the outline width must be in None proposed proportion to the letter width. Updated: 9 -30 -2010 Updated: 9 -30 -2010 REF CHECKLIST ITEM NOTES An outline width of 1/8" is the appropriate sign dimension. TRADEMARKS, CORPORATE LOGOS, AND GRAPHICS X 4.f The ARB may require that the color and scale of standard None proposed templates for trademarks, service marks, corporate logos and graphics be modified. When used, trademarks, service marks, corporate logos and /or graphics should be incorporated as an integral part of the overall sign. LIGHTING X 8.e.i External illumination (or no illumination) is preferred for OK — internal freestanding signs. X 5.f Any internal illumination is considered to contribute to visual OK — internal clutter and will be limited. The design will be evaluated for size, balance, complexity, and distance from and relationship to the Entrance Corridor. X 5.e External Illumination should be shielded and not create glare. None proposed Lighting should be aimed so as not to project illumination beyond the sign. All external light sources shall be white. X 8. e. ii Ground mounted lighting should be shielded by landscaping so None proposed that it is not visible from any adjacent property or right -of- way. X 5.h An exposed light source that forms the body of a sign, (such as None proposed exposed neon signs), shall not be used. Updated: 9 -30 -2010 Updated: 9 -30 -2010 REF CHECKLIST ITEM NOTES X 5.g All illumination shall be non - blinking. None proposed X 5.c External illumination (or no illumination) is preferred for None proposed approved graphics /logos; internal illumination may be considered for approval. X 8.e.iv Cabinet signs shall have a non - illuminated background, or an Issue — not addressed on the sign drawing opaque (zero light transmission) background. Cabinet signs shall be constructed such that no light spills OK outward from the top, bottom, sides or back. X 8.e.iii Channel letters (although not likely appropriate for N/A freestanding signs) with translucent faces shall be constructed such that no light spills outward from the top, bottom, sides or back. If back -lit (halo -lit), the faces and returns of channel letters shall be opaque. ARB ACTIONS X (ARB Billboards are inappropriate for the Entrance Corridors. None proposed Action Memo: 1/19/10) No refacing design (no combination of colors, images, text and layout) will make the billboard an appropriate appearance. Existing billboards may not increase in size and may not include modifications beyond the existing sign surface. No new illumination of any kind may be added to the billboard. Updated: 9 -30 -2010 Updated: 9 -30 -2010 REF CHECKLIST ITEM NOTES X (ARB Reader boards shall have an opaque background. None proposed Action Memo: 1/19/10) Only the letters may be illuminated, but illumination is not required. Reader boards shall not exceed 40% of the size of the overall sign face. The background color of the reader board shall be black or some other color already on the sign face. Construction of the reader board shall be integral with the main sign. The track holding the letters shall have minimal visual impact. X (ARB Synthetic stucco is acceptable for signs if mounted on a solid None proposed Action surface such as concrete block and if limited to use as a flat Memo: surface as a background for lettering. 5/4/09) Styrofoam backing is not acceptable. X Red acrylic 42283 has been determined to be an inappropriate None proposed color for signs. Pantone color match for 2283 is 485C. Red 92793 has been approved as an acceptable substitute. Pantone color match for 2793 is 187C. X (ARB Scale, location, proximity to existing building(s), quality of OK Action sign materials, and sign height and other pre- existing Updated: 9 -30 -2010 Updated: 9 -30 -2010 REF CHECKLIST ITEM NOTES Memo: conditions determine how much planting is required at the 10/5/09) base of the freestanding sign. X If LED lighting is proposed the sign drawing must state The Issue: note not on drawing level of illumination provided by the LED lights will not exceed the illumination produced by a single stroke of 30 milliamp (ma) neon. X Internal LED for the gas pricing: Daytime intensity limited to Issue: note not on drawing 70% of maximum intensity; Nighttime intensity limited to 16% of maximum intensity with automatic dimming at dusk. X ARB Visual clutter resulting from adjacency, for example at the OK Action Hardee's locations, is a reasonable basis for not allowing Memo: illumination of the graphic. 5/7/12 Updated: 9 -30 -2010