HomeMy WebLinkAboutARB201300066 Checklist 2013-05-28ARB COMPREHENSIVE SIGN REVIEW APPROVED CONDITIONS PROJECT #/NAME: ARB- 2013 -34 Rivanna Plaza, Buildings A & B ARB 13 -66, Market Street Wineshop SIGN FEATURE APPROVED CRITERIA SIGN TYPE Channel letter OK LETTER FACE COLOR White OK TRIM CAP/RETURN COLOR Bronze OK RACEWAY COLOR To match the color of the wall to which the sign is attached Direct - mount LOCATIONS Centered horizontally and vertically in the approved sign band areas as shown on the approved elevation drawings (attached) OK LOGO GRAPHICS DETAILS No limit to graphic colors as long as total number is limited to three, plus black and white. None proposed ILLUMINATION DETAILS Signs may be internally illuminated OK — internal neon LETTER TYPE FONT Unlimited This form outlines the specific design criteria established for signs at this location. All standard ARB Sign Guidelines also apply. SIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business ARB 13 -66, Market St. Wineshop Updated: 5 -20 -2010 REF CHECKLIST ITEM NOTES TYPE X 9.b For internally illuminated signs, channel lettering OK — channel letter (mounted on a raceway or individual letters) is preferred to cabinet signs. X 5.b When channel letters cannot be adequately accommodated, N/A internally illuminated cabinet signs may be considered. X 6 Reader boards are discouraged. None proposed MATERIALS X 4.c Materials used in the sign should complement the building OK being served by the sign. COLOR X 4.e Color for raceway- mounted channel letters, the raceway N/A — direct -mount shall match the wall color. Sign colors must be harmonious with each other. OK — meets approved criteria Sign colors must not clash with the site, when viewed in OK daylight and at night. Overly intense color, (such as dayglo or fluorescent None proposed colors), are prohibited. Use of three colors or less (black and white considered as OK — meets approved criteria colors) Additional colors may be approved if they contribute to the sign balance /unity. SIZE, SCALE, PROPORTION, AND LOCATION X 4.b Signs may not exceed the size, height and setback Denied —per S. Wright requirements as outlined in Section 4.15 of the Albemarle No building frontage provided County Zoning Ordinance (unless sign has a variance). tenant needs to apply for a Zoning Clearance and REF CHECKLIST ITEM NOTES possibly an AC permit too. X Appendix A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall OK A.A area is a good working proportioning system for placing a sign. X Appendix Color, form, surface pattern, shape, and disposition of OK A.A.4 elements and openings in an architectural design can affect our perception of scale and can impact the appearance of a sign on a building. X 9.d The wall sign's size must coordinate with the architectural OK — in approved sign band element's size. The sign should not over -crowd the architectural element, OK the wall, or the sign area. Buildings and building elements should not be used as OK billboards. X 9.a Wall signs must integrate with the building's architecture. OK — in approved sign band The sign placement should not obscure architectural OK — in approved sign band features or details, (such as cornices, windows, columns, pilasters and paneling). X 9.d An appropriate height for channel letters in a 30" high sign N/A band is 18 ". This allows 6" of unoccupied space above and below the N/A letters. 4" of clear space above, below, and to the sides of a OK — 5" of clear space above and below sign channel letter sign is considered a minimum, with larger clearances required for larger sign bands. Degree of visibility, the distance from the Entrance OK Corridor, and the architectural design of the building /area REF CHECKLIST ITEM NOTES will determine sign size, placement, and proportions. X 4.d Lettering should be in proportion (font size and typeface style) to the sign and the building. OK Use of three typefaces or less. OK— 1 Additional typefaces may be approved if they contribute to a balanced /legible /unified sign design. N/A X 9. e. iv The width of the outline must be in proportion to the width of the letter. None proposed An outline width of 1/8" has been found to be an appropriate sign dimension. TRADEMARKS, CORPORATE LOGOS AND GRAPHICS X 4.f The ARB may require that the color and scale of standard templates for trademarks, service marks, corporate logos and graphics be modified. None proposed When used, trademarks, service marks, corporate logos and /or graphics should be incorporated as an integral part of the overall sign. X 5.a External (or no) illumination is preferred for approved graphics /logos; N/A X 5.b internal illumination may be considered for approval on a case -by -case basis. N/A LIGHTING X 9.e.i External (or no) illumination is preferred for wall signs. OK — internal channel letter X 5.f Any internal illumination is considered to contribute to visual clutter and will be limited. OK REF CHECKLIST ITEM NOTES X 5.c Internal illumination design approval will be evaluated on OK size, balance, complexity, and distance from the Entrance Corridor. X 9. e. iv The backgrounds of such cabinet signs must be made None proposed opaque (zero light transmission). X 5.e External illumination should be shielded and not create None proposed glare. All external light sources shall be white. None proposed X 9. ii Sign lighting (external) should be shielded so that it None proposed illuminates only face of the sign and does not shine beyond the edge of the sign. X 9. iii Channel letters with translucent faces must have no light OK spilling outward from the top, bottom, sides or back. Faces and returns of channel letters shall be opaque when N/A back -lit (halo -lit). X 9. iv Cabinet signs shall have a non - illuminated background, or None proposed an opaque (zero light transmission) background. Cabinet signs shall be constructed such that no light spills N/A outward from the top, bottom, sides or back. X 5.g All illumination shall be non - blinking. None proposed X 5.h An exposed light source that forms the body of a sign, None proposed (such as exposed neon signs), shall not be used in the Entrance Corridors. ARB ACTIONS X If LED lighting is proposed the sign drawing must state N/A — neon The level of illumination provided by the LED lights will not exceed the illumination produced by a single stroke of 30 milliamp (ma) neon. X Red acrylic 92283 has been determined to be an None proposed REF CHECKLIST ITEM NOTES inappropriate color for signs. Pantone color match for 2283 is 485C. Red 92793 has been approved as an acceptable substitute. Pantone color match for 2793 is 187C. X ARB Visual clutter resulting from adjacency, for example at the N/A Action Hardee's locations, is a reasonable basis for not allowing Memo: illumination of the graphic. 5/7/12