Loading...
HomeMy WebLinkAboutSDP202200046 Correspondence 2022-11-14•see 0 f 608 Preston Avenue P 434.295.5624 Suite 200 IF434.295.1800 T I M M O N S GROUP Charlottesville, VA 22903 www.timmons.com November 11, 2022 Andy Reitelbach Senior Planner II County of Albemarle Community Development 401 McIntire Rd, North Wing Charlottesville, VA 22902 RE: SDP2022-00046 TJACH Premier Circle — Final Site Plan Review - Comment Response Letter Dear Mr. Reitelbach: We have reviewed all of your comments from August 12, 2022, and made the necessary revisions. Please find our responses to the comments below in bold lettering. New Comments — First Review of TJACH Premier Circle — Final Site Plan (SDP2022-00046): 1. [32.5.2(a)] The application number for this project is SDP2022-00046. Revise the cover sheet to include this number. The application number has been added to the cover as requested. 2. [General Comment] Please note that additional comments may be provided with future submissions of the final site plan for this project, depending on revisions that are made and the comments provided by other reviewing departments and agencies. Comment Acknowledged. Comments from SDP2022-00019 —TJACH Premier Circle — Initial Site Plan Action Letter: The original comments from the review and action letter for SDP2022-00019 are in gray font. Follow-up comments from the review of the final site plan, SDP2022-00046, are in black font. Please address these follow-up comments as well. 1. [ZMA2020-00011] The final site plan must demonstrate conformance with the application plan, the code of development, and the proffer statement approved by the Board of Supervisors with the zoning map amendment request ZMA2020-00011. (Comment still applies.) ENGINEERING I DESIGN I TECHNOLOGY It is believed that the final site plan does show conformance with the application plan. If there is something specific that is being seen, then please advise so we can revise the plans accordingly. 2. [SE2020-00023] The final site plan must demonstrate conformance with the special exception approved by the Board of Supervisors with the request SE2020-00023. (Comment still applies.) Comment Acknowledged. It is believed that the site plan is in conformance with the special exception approved by the Board of Supervisors. If there is something specific being seen, please advise so we can revise the plans accordingly. 3. [General Comment] The final site plan must demonstrate conformance with all requirements of Section 18-32.6 of the Zoning Ordinance. The checklist for the initial site plan requirements is helpful as a good place to start. That checklist can be found at the following link: https://www.albemarle.org/home/showpublisheddocument/1014/6375408114047300 00. (Comment still applies.) It is believed that the final site plan is in conformance with the required Zoning Ordinances. Please provide specific comments so they can be addressed and revised accordingly. 4. [32.5.2(a)] On the cover sheet of the plan, provide the zoning district, and all zoning overlay districts, that apply to the subject property. The zoning district is NMD. The applicable zoning overlay districts are Managed Steep Slopes, Airport Impact Area, and Entrance Corridor. (Comment addressed.) Addressed 5. [32.5.2(a)] On the cover sheet of the plan, identify the approved ZMA and SE requests that apply to this project—ZMA2020-00011 and SE2020-00023. (Comment addressed.) Addressed 6. [32.5.2(a)] Provide copies of the ordinance, resolution, and proffer statement, including any conditions of approval, on the site plan. (Also include a copy of the approved resolution for SE2020-00023 on this sheet.) A copy of the approved resolution for SE2020-0023 has been provided on Sheet C1.2. 7. [32.5.2(a)] On the cover sheet of the plan, provide the assigned site plan number. (Also provide the final site plan application number— SDP2022-00046.) The site plan number has been added to the cover sheet. 8. [32.5.2(a)] On the cover sheet of the plan, provide a full signature panel for the signatures of all relevant County and partner agency officials, for when the site plan is ready to be approved. (Comment addressed.) Addressed 9. 32.5.2(a)] Provide the source of the topography and the source of the survey. (Comment addressed.) Addressed 10. [32.5.2(a)] Provide, on the cover sheet, the most recently recorded legal instrument information for the subject property and Premier Circle. (Comment addressed.) Addressed 11. [32.5.2(a)] Clarify the uses proposed by each block/phase. The use is listed as accessible supportive housing; however, Block 1 does not allow residential uses. Also, provide the number of residential units proposed, and the density of the development. The use of accessible supportive housing is not one of the permitted uses in the code of development. Use the COD language to identify the proposed use. (Comments still apply. The labels for the blocks appear to be mixed up. Block 1, according to the ZMA, is the smaller and southernmost portion of the parcel, along Route 29; however, the overall phasing plan on sheet C0.1 and the acreage notes on the cover sheet identify this area as block 2. What page of the code of development is supportive housing on? Special needs housing does not appear as a listed use either. The language of the COD must be used. Provide the density of Phase 1.) The overall site plan and the notes on the cover sheet have been revised and the labels for the Blocks have been changed as needed. Phase 1 has been redescribed as "special needs housing" as called out on sheet 3 of the COD and also called out via the reference made on sheet 1 of the COD to section 20A.8.a of the Albemarle County Code of ordinances. Density for phase 1 can be found under "Proposed Use" of the site data information on the cover sheet as well as on the site layout sheet C4.0 12. [32.5.2(a)] On the cover sheet of the plan, revise the setback notes. Several of the stated setbacks do not match what is listed in the approved COD for this development. (The side and rear setbacks for Block 2 are flipped under the setback notes on the cover sheet.) The set backs on the cover have been revised as needed. 13. [32.5.2(b)] On the cover sheet of the plan, provide the proposed use and the maximum acreage of the site occupied by each use, including by each block of the proposed development. (See comment number 11 above. Accessible supportive housing does not appear as a listed use in the COD. Use the language provided in the COD.) Language found in the COD is now used on the cover sheet. 14. [32.5.2(b)] On the cover sheet of the plan, provide the percentage and acreage of open space. (Provide the specific amount proposed for Phase 1, on the cover sheet.) Comment Acknowledged. The information has been added to the cover sheet as requested. 15. [32.5.2(b)] On the cover sheet of the plan, provide the maximum height of all structures, including number of stories, as there is a limit on stories identified in the COD. (The maximum building height for Block 2 appears to be four stories, not three as is listed on the cover sheet.) The cover sheet and plan sheet C4.0 have been updated to call out the building as 4 stories. 16. [32.5.2(b)] On the cover sheet of the plan, revise the schedule of parking on the site. The parking requirements are based on use, not on the phase in which it is developed. With 80 units provided in phase 1, a minimum of 28 parking spaces are required (if all 80 units are less than 500 sq. ft.). Also, ensure there continues to be sufficient parking provided based on the other buildings that are proposed to remain, along with their unit type. (Clarify how many parking spaces will remain in the other phase areas. Those continuing uses must also have sufficient parking while Phase 1 is redeveloped.) The number of remaining parking spaces is now stated in the Site Data on the Cover Sheet. The remaining parking spaces are also called out on Sheet C2.1. 17. [32.5.2(b)] Clarify how many units (and of what type/square footage/number of bedrooms) are remaining in the existing buildings that will continue to operate along with the new phase one building. This clarification is also needed to help staff accurately count the number of required parking spaces. (What is remaining in use in the other phase areas while Phase 1 is redeveloped? It appears that the buildings in phases 2 and 3 will continue to be in use for the time -being. Those continuing uses must be accounted for when providing parking, to ensure too much parking is not removed.) An Exhibit has been provided in the submission showing the breakdown of units during and after construction. 18. [32.5.2(b)] On the landscape plan, provide the maximum amount of paved parking and other vehicular circulation areas. (Comment addressed.) Addressed 19. [32.5.2(c)] If the development is proposed to be phased, as it appears to be, provide clear phase lines on the site layout sheets identifying the various proposed phases. All improvements and features required by each phase must be included within the appropriate phase lines. Also, clearly delineate between Block 1 and Block 2 on the site layout sheet. (Revise the block numbers on the overall development plan sheet. They appear to be flipped from how they are identified in the approved rezoning. There appears to be additional parking included in the phase 1 lot that is not depicted as being a part of phase 1 on the overall development plan sheet. The phase lines also need to include the work that is proposed to be done to Premier Circle.) The phase lines have been revised and the block numbers have been corrected. 20. [32.5.2(e)] Provide the existing landscape features on the site, as described in section 32.7.9.4(c). (Comment addressed.) Addressed 21. [32.5.2(f)] Indicate whether the site is located within the watershed of a public water supply reservoir. (Revise the cover sheet. Meadow Creek is not located within a public water supply watershed.) The cover sheet site data has been revised accordingly. 22. [32.5.2(i)] On the site plan, provide any existing or proposed access easement, rights -of - way, and travelways. (Comment addressed.) Addressed 23. [32.5.2(i)] On the site plan, provide the right-of-way lines and widths for all adjacent streets or other rights -of -way. (Comment addressed.) Addressed 24. [32.5.2(i)] On the site plan, provide the centerline radii and pavement widths for any proposed travelways. (Comment addressed.) Addressed 25. [32.5.2(j); 32.5.2 (k)] Label all existing and proposed water, sewer, and storm drainage easements by type and include a size/width measurement. For existing easements, state the deed book and page of the recorded instrument. For proposed easements, an easement plat will need to be submitted, reviewed, approved, and recorded at the courthouse prior to approval of the final site plan being granted. (An easement plat will need to be submitted for review and approval prior to approval of the final site plan.) Comment Acknowledged. An easement plat will be provided prior to site plan approval. 26. [32.5.2(I)] Label all existing and proposed utility easements by type and include a size/width measurement. For existing easements, state the deed book and page of the recorded instrument. For proposed easements, an easement plat will need to be submitted, reviewed, approved, and recorded at the courthouse prior to approval of the final site plan being granted. (An easement plat will need to be submitted for review and approval prior to approval of the final site plan.) Comment Acknowledged. An easement plat will be provided prior to site plan approval. 27. [32.5.2(m)] Provide the location of the existing and proposed ingress to and egress from the property. (Comment addressed.) Addressed 28. [32.5.2(m)] Show the distance to the centerline of the nearest existing street intersection from the proposed ingress and egress. (Also show the distance from the site entrance off Premier Circle to the intersection of Premier Circle with Route 29.) The distance to the intersection of Premier Circle with Route 29 is now shown on Sheet C4.0. 29. [32.5.2(n)] Provide the locations and dimensions of all existing and proposed improvements on the site, including the following: a Maximum footprint and height of structures. (Provide the footprint of the phase 1 building on the site layout plan.) Addressed b Walkways. (Comment addressed.) Addressed c Fences and/or walls. (Comment addressed.) Addressed d Trash containers. The dumpster area must be screened. Provide more information on this screening. (Comment addressed.) Addressed e Parking lots and other paved areas. (Comment addressed.) Addressed f Loading, service, and construction areas. (Comment addressed.) Addressed g Signs. (Comment addressed.) Addressed h Proposed paving materials for any paved improvements. (Comment addressed.) Addressed Retaining walls, including height. (Identify the heights of all retaining walls on the layout plan.) Wall heights are called out on the grading spot plans. Outdoor lighting. (See comments below (#30) for comments regarding outdoor lighting.) Comment Acknowledged k Landscaped areas and open space. (See comments below for comments regarding landscaped areas and open space.) Comment Acknowledged 30. [32.5.2(n)] Provide a lighting plan that complies with Section 18-4.17 and 18-32.7.8 of the Zoning Ordinance, as well as any relevant conditions of the approved special exception and rezoning. a (The LLF must be at 1.0. Revise the luminaire schedule and associated photometric plan.) The Lighting and photometric plan has been updated accordingly. 31. [32.5.2(o)] Identify all areas, if any, proposed to be dedicated to public use, and identify the entity (VDOT, the County, etc.) to which those areas will be dedicated. Areas of dedication will require a plat and/or deed. (An easement plat will need to be submitted for review and approval prior to approval of the final site plan.) Comment acknowledged. An easement and subdivision plat will be submitted for review. 32. [32.5.2(p)] Provide a landscaping plan that complies with Section 18-32.7.9 of the Zoning Ordinance, including the tree conservation checklist if proposed, as well as any relevant conditions of the approved special exception and rezoning. a (Landscaping along Premier Circle must be provided with this phase. Each phase must be able to stand separately from the others, so street landscaping cannot be delayed until future phases.) Due to existing and proposed utilities as well as other factors, there is not adequate space for and street tree plantings on this phase. Please specify if additional coordination with the city is required to resolve this comment. b (Specify that the canopy is at 10 years maturity. That is when canopy requirements are measured.) The 10-year tree canopy is provided on sheet L2.0 in the Plant Schedule as well as the total provide tree canopy for this Phase. 33. [32.5.2(q)] On the cover sheet, provide the estimated traffic generation figures for this facility. (Comment not addressed.) A traffic generation table has been added to the cover sheet. 34. [32.5.2(r)] Provide a legend showing all symbols and abbreviations used on the plan. (Comment addressed.) Addressed 35. [ZMA2020-00011] The required transit stop does not appear to be identified on the site plan. Depict the location of this transit stop and its improvements. (This transit stop will be required to be constructed following commencement of the construction of Phase 1. An LOR or minor site plan amendment may be required at that time for this transit stop, as the proposed improvements are not currently shown on this site plan.) Comment Acknowledged 36. [ZMA2020-00011] Provide the required sidewalk along Premier Circle. (The sidewalk improvements will need to be included in Phase 1 in the overall development plan.) Sidewalk improvements have been added to the phase 1 site plan and are to be constructed in parallel with phase 1 construction. 37. [ZMA2020-00011] Provide the required bike racks on the property, as required by the application plan. (Comment addressed.) Addressed 38. [ZMA2020-00011] Show on the site plan the improvements to Premier Circle and the proffered transit stop that are required by the approved proffer statement. (Comment addressed.) Addressed 39. [ZMA2020-00011] Provide a table, calculations, or in some other way demonstrate that the required amount of green space and amenities is being provided on the site with this development. Those areas must also be labeled on the site plan. At least 2,500 square feet of the amenity space must be provided with Phase 1. (On the landscaping plan, where the amenity spaces are depicted in the inset, also include the minimum required of 2,500 square feet, along with the amount proposed in each space. Provide separate calculations for the amenity space and the green space (although they can overlap).) The Amenity Space breakdown is shown on sheet L1.2 40. [ZMA2020-00011] Provide the required recreation facilities as found in 18-4.16. Otherwise, submit a substitution request for the Director of Planning to consider. (The recreational facilities do not meet the requirements of 18-4.16. Submit a substitution request if facilities like the community garden are desired. The community garden area must be a minimum of 2,000 square feet.) The amenity space breakdown is show on sheet L1.2. 41. [ZMA2020-00011] The code of development requires at least 60% of the residential units to be affordable. Identify the affordable units on the site plan. (Provide a note on the cover sheet (under the proposed use works) stating that all 80 units proposed for this phase will be designated as affordable units in accordance with ZMA2020-00011. Also provide the minimum number required by this phase (60% of the 80 units to be constructed).) A note has been added as requested. Comments from Other Reviewing Departments, Divisions, and Agencies: Albemarle County Engineering Services (Engineer) John Anderson, janderson2@albemarle.org — Review pending; comments will be forwarded to applicant upon receipt by Planning staff. Albemarle County Information Services (E911) Andy Slack, aslack@albemarle.org — No objections at this time. Albemarle County Architectural Review Board (ARB) Khris Taggart, ktaggart@albemarle.org — Review pending; comments will be forwarded to applicant upon receipt by Planning staff. Albemarle County Building Inspections Betty Slough, bslough@albemarle.org— Review pending; comments will be forwarded to applicant upon receipt by Planning staff. Albemarle County Department of Fire -Rescue Howard Lagomarsino, hlagomarsino@albemarle.org — Review pending; comments will be forwarded to applicant upon receipt by Planning staff. Albemarle County Service Authority (ACSA) Richard Nelson, rnelson@serviceauthority.org— Requested changes; see the comments below: 1. C0.1— Refer to attached PDF for utility layout for current and future phases. Coordination for utility layouts have been made and the utilities have been revised accordingly. 2. C4.0 — a. Refer to C0.1 for Phase 1 utility layout. Sheet has been revised for Utility Layouts b Locate hydrant and meter outside of pavement. The hydrant and meter have been relocated as requested c Callout new fire hydrant. All new FHA's have been called out. Virginia Department of Transportation (VDOT) Doug McAvoy, douglas.mcavoy@vdot.virginia.gov— Review pending; comments will be forwarded to applicant upon receipt by Planning staff. We have included PDF copies of the plans and calculations for your review. If you have any questions or comments, please feel free to give me a call at 434.295.5624 or email Jonathan.showalter@timmons.com . Sincerely, Jonathan Showalter, PE Project Manager