HomeMy WebLinkAboutARB201300124 Checklist 2013-09-16 SIGN REVIEW CHECKLIST with REFERENCES—Wall Sign, Single Business
ARB 201300124, Jimmy John's Sign
October 8, 2013
REF CHECKLIST ITEM NOTES
TYPE
X 9.b For internally illuminated signs, channel lettering N/A—proposed internal illumination of existing logo can
(mounted on a raceway or individual letters) is preferred to only
cabinet signs.
X 5.b When channel letters cannot be adequately accommodated, N/A—proposed internal illumination of existing logo can
internally illuminated cabinet signs may be considered. only
X 6 Reader boards are discouraged. None proposed
MATERIALS
X 4.c Materials used in the sign should complement the building N/A—proposed internal illumination of existing logo can
being served by the sign. only
COLOR
X 4.e Color for raceway-mounted channel letters, the raceway N/A—proposed internal illumination of existing logo can
shall match the wall color. only
Sign colors must be harmonious with each other. N/A—proposed internal illumination of existing logo can
only
Sign colors must not clash with the site, when viewed in N/A—proposed internal illumination of existing logo can
daylight and at night. only
Overly intense color, (such as dayglo or fluorescent N/A—proposed internal illumination of existing logo can
colors), are prohibited. only
Use of three colors or less (black and white considered as N/A—proposed internal illumination of existing logo can
colors) only
Additional colors may be approved if they contribute to the
sign balance/unity.
SIZE, SCALE, PROPORTION,AND LOCATION
X 4.b Signs may not exceed the size, height and setback OK- proposed internal illumination of existing logo can
requirements as outlined in Section 4.15 of the Albemarle only
1
REF CHECKLIST ITEM NOTES
County Zoning Ordinance (unless sign has a variance).
X Appendix A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall N/A—proposed internal illumination of existing logo can
A.A area is a good working proportioning system for placing a only
sign.
X Appendix Color, form, surface pattern, shape, and disposition of
A.A.4 elements and openings in an architectural design can affect
our perception of scale and can impact the appearance of a
sign on a building.
X 9.d The wall sign's size must coordinate with the architectural N/A—proposed internal illumination of existing logo can
element's size. only
The sign should not over-crowd the architectural element,
the wall, or the sign area.
Buildings and building elements should not be used as
billboards.
X 9.a Wall signs must integrate with the building's architecture. N/A—proposed internal illumination of existing logo can
only
The sign placement should not obscure architectural
features or details, (such as cornices, windows, columns,
pilasters and paneling).
X 9.d An appropriate height for channel letters in a 30" high sign N/A—proposed internal illumination of existing logo can
band is 18". only
This allows 6" of unoccupied space above and below the
letters.
4" of clear space above, below, and to the sides of a
channel letter sign is considered a minimum, with larger
clearances required for larger sign bands.
Degree of visibility, the distance from the Entrance
Corridor, and the architectural design of the building/area
2
REF CHECKLIST ITEM NOTES
will determine sign size,placement, and proportions.
X 4.d Lettering should be in proportion (font size and typeface N/A—proposed internal illumination of existing logo can
style) to the sign and the building. only
Use of three typefaces or less.
Additional typefaces may be approved if they contribute to
a balanced/legible/unified sign design.
X 9.e.iv The width of the outline must be in proportion to the width N/A—proposed internal illumination of existing logo can
of the letter. only
An outline width of 1/8" has been found to be an
appropriate sign dimension.
TRADEMARKS, CORPORATE LOGOS AND GRAPHICS
X 4.f The ARB may require that the color and scale of standard OK —proposed internal illumination of existing logo can
templates for trademarks, service marks, corporate logos only
and graphics be modified.
When used, trademarks, service marks, corporate logos
and/or graphics should be incorporated as an integral part
of the overall sign.
X 5.a External (or no) illumination is preferred for approved Internal illumination proposed
graphics/logos;
X 5.b internal illumination may be considered for approval on a OK— logo can well integrated with overall sign
case-by-case basis. • Proposed opaque background
• Only text and circular outline to illuminate
Illumination: Mostly white(matching exist. white channel
letters),red PMS 186 limited to letters JJ.
LIGHTING
X 9.e.i External (or no) illumination is preferred for wall signs. N/A—proposed internal illumination of existing logo can
only
3
REF CHECKLIST ITEM NOTES
❑ 5.f Any internal illumination is considered to contribute to
visual clutter and will be limited.
❑ 5.c Internal illumination design approval will be evaluated on
size, balance, complexity, and distance from the Entrance
Corridor.
X 9.e.iv The backgrounds of such cabinet signs must be made OK—notes on drawing calling for opaque background
opaque(zero light transmission).
X 5.e External illumination should be shielded and not create N/A
glare.
All external light sources shall be white. N/A
X 9.ii Sign lighting (external) should be shielded so that it N/A
illuminates only face of the sign and does not shine beyond
the edge of the sign.
X 9.iii Channel letters with translucent faces must have no light N/A—proposed internal illumination of existing logo can
spilling outward from the top, bottom, sides or back. only
Faces and returns of channel letters shall be opaque when
back-lit (halo-lit).
X 9.iv Cabinet signs shall have a non-illuminated background, or OK
an opaque (zero light transmission)background.
Cabinet signs shall be constructed such that no light spills OK
outward from the top, bottom, sides or back.
X 5.g All illumination shall be non-blinking. None proposed
X 5.h An exposed light source that forms the body of a sign, None proposed
(such as exposed neon signs), shall not be used in the
Entrance Corridors.
ARB ACTIONS
X If LED lighting is proposed the sign drawing must state OK—note on drawing
The level of illumination provided by the LED lights will
not exceed the illumination produced by a single stroke of
30 milliamp (ma) neon.
4
REF CHECKLIST ITEM NOTES
X Red acrylic#2283 has been determined to be an OK— graphic uses Red PMS 186
inappropriate color for signs.
Pantone color match for 2283 is 485C.
Red#2793 has been approved as an acceptable substitute.
Pantone color match for 2793 is 187C.
X ARB Visual clutter resulting from adjacency, for example at the OK—no visual clutter from adjacency
Action Hardee's locations, is a reasonable basis for not allowing
Memo: illumination of the graphic.
5/7/12
5
ARB COMPREHENSIVE SIGN REVIEW APPROVED CONDITIONS
PROJECT#/NAME: ARB-2006-56: Wachovia Bank and Shops at Rio Road—Retail Building
TAX MAP/PARCEL#: Tax Map 61, Parcel 122
ARB 201300124, Jimmy John's Sign
SIGN FEATURE APPROVED CONDITION NOTES
SIGN TYPE N/A—proposed internal
Channel Letters illumination of existing logo
can only
LETTER FACE COLOR White or N/A—proposed internal
blue(PMS 280M) illumination of existing logo
can only
TRIM CAP N/A—proposed internal
COLOR/RETURN COLOR Bronze illumination of existing logo
can only
RACEWAY COLOR N/A—proposed internal
N/A illumination of existing logo
can only
CABINET FACE COLORS N/A—proposed internal
N/A illumination of existing logo
can only
SIZE LIMITATIONS North and south elevations,tower and N/A—proposed internal
shorter bays of building: 2' high max; Taller illumination of existing logo
bays of building: 3' high max can only
LOCATION(S) Signs must be centered within the areas
designated on the approved elevations. N/A—proposed internal
Where brick detailing encloses an approved illumination of existing logo
sign area, signs must not extend over or on can only
top of the brick detailing.
MOUNTING DETAILS N/A—proposed internal
Letters mounted direct to wall illumination of existing logo
can only
LOGO/GRAPHICS
DETAILS None specified
ILLUMINATION Ok—
DETAILS • Proposed opaque
background
• Only text and circular
Internally illuminated channel letters outline to illuminate
• Illumination: Mostly white
(matching exist.white
channel letters), red PMS
186 limited to letters JJ.
TEXT N/A—proposed internal
Not specified illumination of existing logo
can onlv
LETTER TYPE/FONT N/A—proposed internal
Not limited illumination of existing logo
can only
ALL ARB GUIDELINES
APPLY.
FREESTANDING SIGNS: all externally illuminated sign panels on brick monument,brick to match retail building
brick. Fixtures are B-K Lighting Microstar FTD(20W)28 Flood(MRII), Bronze, 2 each side.
1. Route 29 Entrance: Background: white or blue(PMS 280M)or gold(PMS 129M);letters: black
2. Rio Road: Retail panel backgrounds: white or blue(PMS 280M)or gold(PMS 129M); letters: black. Wachovia
panel: background: silver(PMS cool gray 43c)
3. Wachovia Bank: Blue Wachovia background with green and white detailing and white"Wachovia"letters
This form outlines the specific design criteria established for signs at this location.
All standard ARB Sign Guidelines also apply.
Sign location information updated 8/11/09