Loading...
HomeMy WebLinkAboutSDP201500058 Action Letter Initial Site Plan 2015-02-01LIMIIV\AR Y SIT1.1 0 P TJA IV\ I OR WHI TE'HA 1. L ALBI-j 11 MARLIj SITE DATA OWNER: CROZET DEVELOPMENT SOLUTIONS, 1215 EAST MARKET STREET, SUITE B, CHAR LOTTESVI LILE, VA 22902 DEVELOPER: VUE REALTY PARTNERS, LLC., 1821 AVON STREET, SUITE 200, CHARLOTTESVILLE, VIRGINIA 22902 PHONE 434-979-2900, CONTACT MR. WILLIAM PARK TAX MAP / PARCEL NUMBER: 56-115 PROPERTY ADDRESS: BLUE RIDGE AVENUE, CROZET, VIRGINIA 22932 PROPERTY SIZE: 21.854 ACRES ZONING: R-6 RESIDENTIAL MAGISTERIAL DISTRICT: WHITEHALL COMPREHENSIVE PLAN: CROZET COMMUNITY — URBAN GENERAL (CT-4) DRINKING WATER WATERSHED: LICKINGHOLE CREEK / SOUTH FORK RIVANNA RIVER RESERVOIR PROPOSED USE: MULTI FAMILY RESIDENTIAL TOTAL NUMBER OF UNITS / DENSITY: 126 MULTI FAMILY UN i a - 5.77 UNITS PER ACRE, 54 1 BR UNITS, 72 2BR UNITS DENSITY BONUS FACTORS: NONE WAIVER/VARIANCE REQUESTS: NONE SURVEY SOURCE: HAMRICK ENGINEERING, P.C., 540-248--7407 DATUM: NAVD 1988 BENCHMARK: NAIL IN BLUE RIDGE AVENUE, ELEVATION 698.02 IMPERVIOUS COVER BREAKDOWN: LAND USE: SQ. FT. ACRES BUILDINGS: 69,297 1.591 SIDEWALKS: 28,290 0.649 ASPHALT PARKING PAVING 84,855 1.948 CONCRETE POOL DECK: 4,446 0.102 TOTAL IMPERVIOUS AREA: 186,888 4.290 MAXIMUM PAVED PARKING AND VEHICULAR CIRCULATION AREA: 1.948 ACRES OR 84,855 S.F. SETBACKS: FRONT = 25', SIDE = 15', REAR = 20' MAXIMUM HEIGHT OF STRUCTURE: 35' NUMBER OF EMPLOYEES: NOT APPLICABLE RECREATIONAL AREA: PASSIVE DEDICATED OPEN SPACE = 14.817 ACRES OR 68% OF TOTAL SITE SWIMMING POOL AND CLUB HOUSE AREA PARKING DATA: BUILDING USE: MULTI FAMILY RESIDENTIAL SPACES REQUIRED: 1.5 SPACES PER 1 BED ROOM UNIT 2.0 SPACES PER 2 BED ROOM UNIT TOTAL NUMBER OF 1 BED ROOM UNITS = 54 TOTAL NUMBER OF 2 BED ROOM UNITS = 72 TOTAL SPACES REQUIRED: (1.5 x 54) + (2.0 x 72) = 225 SPACES PROVIDED: SPACES DELINEATED = 218 H.C. PER ADA = 7 TOTAL PROVIDED = 225 ALL SPACES ARE 9'x18' UNLESS OTHERWISE NOTED TRAFFIC GENERATION FIGURES: ITE LAND USE CODE: 280 NEW DAILY TRIPS: 887 AM PEAK: 65 PM PEAK: 87 DISTRICT CO Ul\\[Ty PROJECT SPONSOR V UE REALTY PARTNERS, LLC A T TN: MR. WILLIAM PARK 1821 AVON STREET, SUITE 200 CHARL 0 T TES VILLE, VIRGINIA 22902 PHONE: 434-979-2900 CROZET DEVELOPMENT 0 SOLUTIONS, LLC '0 � � Q JARMANS GAP ROAD Q' - OV HE TI-71Y ALAP SId'Q-P— Itr, 2 E --- N r i r 1` : ` ---.. Hamrick,Brasil W. 156 Laurel Hill Road I Roue 612 East 540-248-7407 Verona, VA 24482 bwheng@verizon.net VIR CIIV\IA PLAN SHEET INDEX SHEET NO. DESCRIPTION SHEET NO. DESCRIPTION 1 TITLE SHEET 10 SITE GRADING PLAN (20 SCALE) 2 PROJECT NOTES AND DETAILS 11 COMPOSITE UTILITY PLAN (50 SCALE) 3 BOUNDARY SURVEY 12 COMPOSITE UTILITY PLAN (50 SCALE) 4 EXISTING TOPOGRAPHIC SURVEY 13 COMPOSITE UTILITY PLAN (50 SCALE) 5 SITE LAYOUT AND DIMENSION PLAN (50 SCALE) 14 LANDSCAPING PLAN (50 SCALE) 6 SITE LAYOUT AND DIMENSION PLAN (20 SCALE) 15 LANDSCAPING PLAN (20 SCALE) 7 SITE LAYOUT AND DIMENSION PLAN (20 SCALE) 16 LANDSCAPING PLAN (20 SCALE) 8 SITE GRADING PLAN (50 SCALE) 9 SITE GRADING PLAN (20 SCALE) PROJECT LEGEND ABBREVIATIONS SYMBOLS CC CENTER TO CENTER PROPOSED WATER LINE CG CURB & GUTTER S PROPOSED SEWER LINE C CENTERLINE. CMP CORRUGATED METAL PIPE EXISTING WATER LINE CONC. CONCRETE ES EXISTING SEWER LINE DIP DUCTILE IRON PIPE 0 DEI TA -- --- --- --- -- EXISTING CONTOURS ESMT EASEMENT ;43 PROPOSED CONTOURS ELEV. ELEVATION EXISTING SANITARY MANHOLE EX. EXISTING PROPOSED SANITARY MANHOLE F.H. FIRE HYDRANT PLAN APPROVAL EXISTING DRAINAGE STRUCTURE GR GROUND SHOT I NV. INVERTL PROPOSED DRAINAGE STRUCTURE LENGTH EXISTING STORM SEWER MH MANHOLE .................. .................................................... --•---..................................................--•-------------............................ PLANNING / ZONING PROPOSED STORM SEWER N/F NOW OR FORMERLY ---�--%- FENCE LINE O.C. ON CENTER--�� R PROPERTY LINE ENGINEER UTILITY POLE PVMT. PAVEMENT GUY WIRE EP EDGE OF PAVEMENT R RADIUS BUILDING OFFICIAL OVERHEAD UTILITY LINE RCP REINFORCED CONCRETE PIPE -----u ---- UNDERGROUND TELEPHONE R.D. ROOF DRAIN � o �G EXISTING POWER UNDERGROUND R W / RIGHT OF WAY �.......................................... ....................... .....................................•- ARCHITECTURAL REVIEW BOARD SAN SANITARY TELEPHONE PEDESTAL WM WATER MAIN EG EXISTING GAS TBM TEMPORARY BENCH MARK FIRE OFFICIAL F/C FACE OF CURB SL PROPOSED SEWER LATERAL T/C TOP OF CURB PROPOSED WATER LATERAL T/P TOP OF PAVEMENT -------- ------- ----- ----------- -------- -- --- --� ACSA T/S TOP OF SIDEWALK EXISTING FIRE HYDRANT T/G TOP OF GROUND PROPOSED FIRE HYDRANT W/ WITH VDOT ............................................................... C.O. SAN. SEW. CLEAN OUT EXISTING CURB & GUTTER IPF IRON PIN FOUND PROPOSED CURB & GUTTER IPS IRON PIN SET REVERSE CURB & GUTTER NOT[: NOT ALL UEGEND STEMS MAY APPEAR N" THESE PLANS i Submittal Types Rev ed and Apr, ved by the Communit Oevel meet Department Data f-�-� F110 `3 ri, )1 )N�`� NUT H 0�,, o BRMIL W. HAMRICK, Jr. LICENSE No. � 31 �o,, • 0 I n "k'0.51 / PLOT DATE.• 11/20/1,5 ,/OB No. 02-0206 SHEET Cl OF C16