HomeMy WebLinkAboutARB201500020 Checklist 2015-02-06SIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business
ARB 201500020, Village Green
02 -24 -2015
REF
CHECKLIST ITEM
NOTES
TYPE
•
9.b
For internally illuminated signs, channel lettering
(mounted on a raceway or individual letters) is preferred to
cabinet signs.
OK — wall tenant panel
•
5.b
When channel letters cannot be adequately accommodated,
internally illuminated cabinet signs may be considered.
N/A
•
6
Reader boards are discouraged.
None proposed
MATERIALS
•
4.c
Materials used in the sign should complement the building
being served by the sign.
OK — MDO board, vinyl
COLOR
•
4.e
Color for raceway- mounted channel letters, the raceway
shall match the wall color.
N/A
Sign colors must be harmonious with each other.
OK — black and white
Sign colors must not clash with the site, when viewed in
daylight and at night.
OK
Overly intense color, (such as dayglo or fluorescent
colors), are prohibited.
None proposed
Use of three colors or less (black and white considered as
colors)
Additional colors may be approved if they contribute to the
sign balance /unity.
OK-2
SIZE, SCALE, PROPORTION, AND LOCATION
•
4.b
Signs may not exceed the size, height and setback
requirements as outlined in Section 4.15 of the Albemarle
County Zoning Ordinance (unless sign has a variance).
OK — per RR
directory sign - -max size 24 sq. ft. each
•
Appendix
A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall
OK
REF
CHECKLIST ITEM
NOTES
A.A
area is a good working proportioning system for placing a
sign.
X
Appendix
Color, form, surface pattern, shape, and disposition of
OK
A.A.4
elements and openings in an architectural design can affect
our perception of scale and can impact the appearance of a
sign on a building.
X
9.d
The wall sign's size must coordinate with the architectural
OK — same design & location as existing sign
element's size.
The sign should not over -crowd the architectural element,
OK
the wall, or the sign area.
Buildings and building elements should not be used as
OK
billboards.
X
9.a
Wall signs must integrate with the building's architecture.
OK
The sign placement should not obscure architectural
OK
features or details, (such as cornices, windows, columns,
pilasters and paneling).
X
9.d
An appropriate height for channel letters in a 30" high sign
N/A
band is 18 ".
This allows 6" of unoccupied space above and below the
letters.
4" of clear space above, below, and to the sides of a
channel letter sign is considered a minimum, with larger
clearances required for larger sign bands.
Degree of visibility, the distance from the Entrance
Corridor, and the architectural design of the building /area
will determine sign size, placement, and proportions.
X
4.d
Lettering should be in proportion (font size and typeface
OK
REF
CHECKLIST ITEM
NOTES
style) to the sign and the building.
Use of three typefaces or less.
OK— 1
Additional typefaces may be approved if they contribute to
a balanced /legible /unified sign design.
N/A
X
9. e. iv
The width of the outline must be in proportion to the width
of the letter.
None proposed
An outline width of 1/8" has been found to be an
appropriate sign dimension.
TRADEMARKS, CORPORATE LOGOS AND GRAPHICS
X
4.f
The ARB may require that the color and scale of standard
templates for trademarks, service marks, corporate logos
and graphics be modified.
None proposed
When used, trademarks, service marks, corporate logos
and /or graphics should be incorporated as an integral part
of the overall sign.
X
5.a
External (or no) illumination is preferred for approved
graphics /logos;
X
5.b
internal illumination may be considered for approval on a
case -by -case basis.
LIGHTING
X
9.e.i
External (or no) illumination is preferred for wall signs.
Existing, external to remain
X
5.f
Any internal illumination is considered to contribute to
visual clutter and will be limited.
N/A
X
5.c
Internal illumination design approval will be evaluated on
size, balance, complexity, and distance from the Entrance
Corridor.
N/A
X
9.e.iv
The backgrounds of such cabinet signs must be made
opaque (zero light transmission).
None proposed
REF
CHECKLIST ITEM
NOTES
X
5.e
External illumination should be shielded and not create
N/A
glare.
All external light sources shall be white.
None proposed
X
9. ii
Sign lighting (external) should be shielded so that it
N/A
illuminates only face of the sign and does not shine beyond
the edge of the sign.
X
9. iii
Channel letters with translucent faces must have no light
None proposed
spilling outward from the top, bottom, sides or back.
Faces and returns of channel letters shall be opaque when
back -lit (halo -lit).
X
9. iv
Cabinet signs shall have a non - illuminated background, or
None proposed
an opaque (zero light transmission) background.
Cabinet signs shall be constructed such that no light spills
outward from the top, bottom, sides or back.
X
5.g
All illumination shall be non - blinking.
None proposed
X
5.h
An exposed light source that forms the body of a sign,
None proposed
(such as exposed neon signs), shall not be used in the
Entrance Corridors.
ARB ACTIONS
X
If LED lighting is proposed the sign drawing must state
N/A — existing lighting to remain
The level of illumination provided by the LED lights will
not exceed the illumination produced by a single stroke of
30 milliamp (ma) neon.
X
Red acrylic #2283 has been determined to be an
OK — no red color proposed
inappropriate color for signs.
Pantone color match for 2283 is 485C.
Red #2793 has been approved as an acceptable substitute.
Pantone color match for 2793 is 187C.
REF
CHECKLIST ITEM
NOTES
X
ARB
Visual clutter resulting from adjacency, for example at the
N/A
Action
Hardee's locations, is a reasonable basis for not allowing
Memo:
illumination of the graphic.
5/7/12
COMPREHENSIVE SIGN CRITERIA — VILLAGE GREEN SHOPPING CENTER
ARB 2013 -98, Tax Map 61W, Section 3, Parcel 21A
SIGN FEATURE
Approved Criteria
SIGN TYPE
Wall panel or hanging panel
Channel letter
LETTER FACE
Panel: Forest Green
COLOR
Channel Letter: White
TRIM CAP COLOR/
Panel: N/A
RETURN COLOR
Channel letter: Bronze
RACEWAY COLOR
Panel: N/A
Channel letter: To match color of wall to which it is attached
PANEL /CABINET
Ivory
FACE COLORS
SIZE LIMITATIONS
Hanging panel: Front & Rear: 21" — 24" (t) x 8' (w)
Wall panel: Front: 21' — 24" (t) x 8' (w)
Rear: as per general sign guidelines without overlapping
brick detailing
LOCATION(S)
Wall Panel: Centered on the wall above the business entrance in both the
front and rear elevations - not permitted on the wall under the colonnade.
Hanging Panel: Centered between the colonnade columns in both the
front and rear elevations.
Channel letter: In the approved sign bands as shown on the photo -
rendering below
LOGO /GRAPHICS
Panel: Forest green border
DETAILS
Channel letter: No limit to graphic colors as long as total number per
sign is limited to three and they contribute to a coordinated appearance.
ILLUMINATION
Panel: No internal illumination; existing wall fixtures may be reused
DETAILS
Channel letter: may be internally illuminated
TEXT
No limits other than standard guidelines
LETTER
No limits other than standard guidelines
TYPE/FONT
MATERIALS
No limits other than standard guidelines
This form outlines the specific design criteria established for signs at this location.
All standard ARB Sign Guidelines also apply.
VILLAGE GREEN SIGN BAND
14' -6"
An,
WIIClgigdiiPbYldP�'P.1PII 01ST DRAFT 0710312013
WSTOMER X VILLAGE GREEN A NOTES FOR CHANGES
LOCATION X
SALESMAN X RP
DESIGNER X CSE A
DATE X 07/03/2013 A
This dome t is the property of Talley Anchor Sgn C NI d g a same manafactarng p d cG s tl sales rights re gab ng th are
expresslyforbdd It is .bmiu,d nd,r a confidential relationship f
special pm-pose, and the recipientisy accepting the doomment asamnes
custody and agrees that this doou ..Lt II act be copied or r.prcd.c.d in
whole or in part, nor its contents revealed in any manner arts anypers-
cept for the purpose for which it was tendered, nor any special feature.
peculiar to this design be incorporated in omer projects,
SIGNS MAY 6E LOCATED IN THESE WALL
AREAS, SUDJECTTO ZONING ORDINANCE
REGULATIONS AND ENTRANCE CORRIDOR
SIGN DESIGN GUIDELINES FOR SIZE, .
DESIGN AND PROPORTION.
SIGNS MAY 6E LOCATED IN THESE WALL
AREAS, SUPJECT TO ZONING ORDINANCE
REGULATIONS AND ENTRANCE CORRIDOR
SIGN DESIGN GUIDELINES FOR SIZE, .
DESIGN AND PROPORTION.
(LEFT & RIGHT SIGN SANDS ARE THE SAME
51ZE AND SHAPE AS THE CENTER
SIGN f5AND)
Tal ley - Anchor
SIGN CO M PAN Y
10-04 Ruriton Blvd Chesapeake, 1123324
Ph. 757 -545 -8802• F- 757- 543 -9132
Completeness Check for Signs
Project # /Name: AR13201500020, Village Green
Date Received at County: _02/06/2015
Date Received in Design Planning: _02/06/2015
Date of Checklist Check: _02/06/2015_ Assigned to /Date: _02/06/2015
FEES
3. ARB Review —Will the permanent sign(s) be constructed in an Entrance Corridor?
(Seethe Entrance Corridor map in the Sign Permit Application packet for a list of Entrance Corridors.)
❑ Yes (This sign will be constructed in an Entrance Corridor and it does not meet the conditions of a $120.00
Comprehensive Sign Review. See ARB requirements next pages.) PAID
❑ Yes (This sign will be constructed in an Entrance Corridor and it does meet the conditions of a Waive Fee
Comprehensive Sign Review. See ARB requirements next pages)
❑ No (This sign will not be constructed in an Entrance Corridor) $ 0.00
FEE TOTAL (Please add all the amounts checked in sections I — 3): $
FREESTANDING SIGNS None Proposed
A. Submittal Requirements
❑ Site plan or latest approved plat showing, to scale, the proposed location of the sign(s) with dimensions.
❑ Distance from the sign to the property lines and/or edge of the VDOT right -of -way.
❑ If the sign will be located in an easement, a letter of approval from the easement holder will be required.
❑ A to -scale color illustration of the proposed sign showing
❑ Dimensions of the sign, including overall height from the ground; cabinet size, length, width and depth; base
size, etc. (Be sure to also include these dimensions on the diagrams provided in the Sign Permit Application packet.)
❑ Proposed lettering and/or graphics in their proposed location.
❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor, also provide a color
illustration of the front and side elevations of the sign showing:
• If internally illuminated, indicate which areas of the sign are opaque and which are illuminated. Internally
illuminated cabinet signs must have opaque backgrounds. (Opaque materials don't allow light to pass through.
When lit only from behind, the color of an opaque material cannot be detected nor can objects be seen through it.)
• Identification of proposed materials and colors. Include standard color id numbers (Pantone, Benjamin Moore,
Acrylic, etc.) for all materials, text, graphics, base, faces, trim caps, returns, etc.
• Provide accurate physical samples of all colors proposed, preferably in the material proposed. (Paint chips that
accurately reflect the proposed colors are acceptable.)
• Provide a site plan showing proposed landscaping around the sign, including botanical names and planting sizes.
• Additional submittal materials may be required if review by the Architectural Review Board is necessary. (The
applicant will be notified if this requirement applies.)
WALL SIGNS
❑ A drawing, to scale, showing dimensions of the sign (length, height, depth). OK
❑ Elevation drawing(s) or modified photograph of the entire building, to scale and in color, showing
❑ The sign location on the building, sign height above grade, and the length of building frontage. (Be sure to also
include these dimensions on the diagrams provided in Appendix B) OK
❑ Sign lettering and /or graphics in their proposed location. OK
❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor also provide a color
illustration of the front and side elevations of the sign showing:
• Indication of sign type (channel letters, cabinet, panel, etc.). OK
• Indicate on the drawings the proposed materials and colors. Include standard color identification numbers
(Pantone, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, faces, trim caps, etc. For channel letter
signs, indicate on the drawing that the raceway color shall match the color of the wall to which the raceway is
attached. OK
• Provide accurate physical samples of all colors proposed in the sign, preferably in the material proposed. (Paint
chips that accurately reflect the proposed colors are acceptable.) N/A
• Location of proposed light fixtures and manufacturer cut sheets describing illumination type, intensity, style,
shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17. N/A -
existing
o For internally illuminated signs, indicate which areas of the sign are opaque and which are illuminated. (Opaque
materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be
detected nor can objects be seen through it.) N/A
ILLUMINATION REQUIREMENTS N/A
❑ The location of proposed light fixtures identified on a plan and/or elevation
❑ Manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must
meet ordinance requirements as outlined in Section 4.17 of the Zoning Ordinance.
NOTES: