HomeMy WebLinkAboutARB201400138 Checklist 2014-11-18RESUBMITTAL REVIEW CHECKLIST
PROJECT #/NAME: AR11201400138, Tiger USA Sign
11 -24 -2014
ARB COMMENT
11 -24 -14 Review
12 -10 -14 Review
X
I . The sign drawing is missing the following:
OK
a) An indication of the sign type (channel letter,
individual letter etc.). A detail of the sign letter
is the best way to show that.
b) Pantone color numbers for the sign. Note:
OK
approved Comprehensive Sign Criteria for
Rivanna Ridge require Red: PMS 187.
c) If a raceway is proposed, the Pantone color
OK
number for the raceway color and a note
indicating the raceway color shall match the
wall to which it is attached.
d) The location (address) of the sign.
OK
e) The sign designer /maker's name /address and
OK
the date of the drawing.
f) The height of the sign band.
Missing
OK - added to drawing
28" (t)
2. A plan view drawing showing the sign's location in
OK - added to drawing
the shopping center was not included in the
Missing
application.
Trim cap and return colors
OK — added to drawing
not on the drawing.
Red: PMS 187
ARB COMPREHENSIVE SIGN REVIEW APPROVED CONDITIONS
PROJECT #/NAME: Rivanna Ridge Shopping Center (Revised February 2011)
TAX MAP/PARCEL #: Tax Map 78, Parcel 73A1
ARB 201400138, Tiger USA Taekwondo Sign
DESIGN CRITERIA
SIGN FEATURE
Giant store
Other stores
SIGN TYPE
Channel letters
Channel letters
Logo /graphics box (one)
(No logo /graphics boxes)
small box signs
OK
LETTER FACE COLOR
Purple (Pantone 259)
Red (Acrylic 2793; Pantone
187) OK
TRIM CAP/RETURN
White
Red
COLOR
Missing
RACEWAY COLOR
To match fascia/sign band OK
CABINET COLORS (face,
Purple (Pantone 259)
n/a
trim, returns)
GRAPHICS COLORS
Red (Pantone 485)
n/a
Purple (Pantone 259)
Green (Pantone 376)
Yellow (Pantone 130)
LOCATION(S)
Channel letters: Centered in sign band
Channel letters: Centered in
and under main gable
sign band OK
Logo /graphics boxes: adjacent to the
"Giant" letters
Small box signs: on the brick wall
along the walkway under the canopy
MOUNTING DETAILS
Channel letters and logo /graphic
Raceway, wireway OK —
boxes: wireway
raceway
Small box signs: Direct to wall
ILLUMINATION DETAILS
Internally illuminated (including LED)
This form outlines the specific design criteria established for signs at this location.
All standard ARB Sign Guidelines also apply.
RESUBMITTAL REVIEW CHECKLIST
PROJECT #/NAME: AR11201400138, Tiger USA Sign
11 -24 -2014
ARB COMMENT
NOTES
X
1. The sign drawing is missing the following:
OK
a) An indication of the sign type (channel letter,
individual letter etc.). A detail of the sign letter
is the best way to show that.
b) Pantone color numbers for the sign. Note:
OK
approved Comprehensive Sign Criteria for
Rivanna Ridge require Red: PMS 187.
c) If a raceway is proposed, the Pantone color
OK
number for the raceway color and a note
indicating the raceway color shall match the
wall to which it is attached.
d) The location (address) of the sign.
OK
e) The sign designer /maker's name /address and
OK
the date of the drawing.
f) The height of the sign band.
Missing
2. A plan view drawing showing the sign's location in
the shopping center was not included in the
Missing
application.
Trim cap and return colors not on the drawing.
Completeness Check for Signs
Project #/Name: ARB 201400138, Tiger USA, Taekwondo
Date Received at County: _11/18/2014
Date Received in Design Planning: _11/18/2014
Date of Checklist Check: _11/20/2014_ Assigned to/Date: _11/18/2014
FEES
3. ARB Review —Will the permanent sign(s) be constructed in an Entrance Corridor?
(Seethe Entrance Corridor map in the Sign Permit Application packet for a list of Entrance Corridors.)
❑ Yes (This sign will be constructed in an Entrance Corridor and it does not meet the conditions of a $120.00
Comprehensive Sign Review. See ARB requirements next pages.)
❑ Yes (This sign will be constructed in an Entrance Corridor and it does meet the conditions of a Waive Fee
Comprehensive Sign Review. See ARB requirements next pages) OK
❑ No (This sign will not be constructed in an Entrance Corridor) $ 0.00
FEE TOTAL (Please add all the amounts checked in sections I — 3): $
FREESTANDING SIGNS None proposed
A. Submittal Requirements
❑ Site plan or latest approved plat showing, to scale, the proposed location of the sign(s) with dimensions.
❑ Distance from the sign to the property lines and/or edge of the VDOT right -of -way.
❑ If the sign will be located in an easement, a letter of approval from the easement holder will be required.
❑ A to -scale color illustration of the proposed sign showing
❑ Dimensions of the sign, including overall height from the ground; cabinet size, length, width and depth; base
size, etc. (Be sure to also include these dimensions on the diagrams provided in the Sign Permit Application packet.)
❑ Proposed lettering and/or graphics in their proposed location.
❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor, also provide a color
illustration of the front and side elevations of the sign showing:
• If internally illuminated, indicate which areas of the sign are opaque and which are illuminated. Internally
illuminated cabinet signs must have opaque backgrounds. (Opaque materials don't allow light to pass through.
When lit only from behind, the color of an opaque material cannot be detected nor can objects be seen through it.)
• Identification of proposed materials and colors. Include standard color id numbers (Pantone, Benjamin Moore,
Acrylic, etc.) for all materials, text, graphics, base, faces, trim caps, returns, etc.
• Provide accurate physical samples of all colors proposed, preferably in the material proposed. (Paint chips that
accurately reflect the proposed colors are acceptable.)
• Provide a site plan showing proposed landscaping around the sign, including botanical names and planting sizes.
• Additional submittal materials may be required if review by the Architectural Review Board is necessary. (The
applicant will be notified if this requirement applies.)
WALL SIGNS
❑ A drawing, to scale, showing dimensions of the sign (length, height, depth). Sign band height not provided
❑ Elevation drawing(s) or modified photograph of the entire building, to scale and in color, showing
❑ The sign location on the building, sign height above grade, and the length of building frontage. (Be sure to also
include these dimensions on the diagrams provided in Appendix B) OK
❑ Sign lettering and /or graphics in their proposed location. OK
❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor also provide a color
illustration of the front and side elevations of the sign showing:
• Indication of sign type (channel letters, cabinet, panel, etc.). Not indicated
• Indicate on the drawings the proposed materials and colors. Include standard color identification numbers
(Pantone, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, faces, trim caps, etc. For channel letter
signs, indicate on the drawing that the raceway color shall match the color of the wall to which the raceway is
attached. Raceway color not addressed. Channel letter color not addressed — PMS 187 required.
• Provide accurate physical samples of all colors proposed in the sign, preferably in the material proposed. (Paint
chips that accurately reflect the proposed colors are acceptable.)
• Location of proposed light fixtures and manufacturer cut sheets describing illumination type, intensity, style,
shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17. Not
provided
o For internally illuminated signs, indicate which areas of the sign are opaque and which are illuminated. (Opaque
materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be
detected nor can objects be seen through it.)
ILLUMINATION REQUIREMENTS
❑ The location of proposed light fixtures identified on a plan and/or elevation Not provided
❑ Manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must
meet ordinance requirements as outlined in Section 4.17 of the Zoning Ordinance. Not provided
NOTES:
Sign location not indicated on drawing
SIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business
Updated: 5 -20 -2010
REF
CHECKLIST ITEM
NOTES
TYPE
•
9.b
For internally illuminated signs, channel lettering
(mounted on a raceway or individual letters) is preferred to
cabinet signs.
•
S.b
When channel letters cannot be adequately accommodated,
internally illuminated cabinet signs may be considered.
•
6
Reader boards are discouraged.
MATERIALS
•
4.c
Materials used in the sign should complement the building
being served by the sign.
COLOR
•
4.e
Color for raceway - mounted channel letters, the raceway
shall match the wall color.
Sign colors must be harmonious with each other.
Sign colors must not clash with the site, when viewed in
daylight and at night.
Overly intense color, (such as dayglo or fluorescent
colors), are prohibited.
Use of three colors or less (black and white considered as
colors)
Additional colors may be approved if they contribute to the
sign balance /unity.
SIZE, SCALE, PROPORTION, AND LOCATION
•
4.b
Signs may not exceed the size, height and setback
requirements as outlined in Section 4.15 of the Albemarle
REF
CHECKLIST ITEM
NOTES
County Zoning Ordinance (unless sign has a variance).
❑
Appendix
A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall
A.A
area is a good working proportioning system for placing a
sign.
❑
Appendix
Color, form, surface pattern, shape, and disposition of
A.A.4
elements and openings in an architectural design can affect
our perception of scale and can impact the appearance of a
sign on a building.
❑
9.d
The wall sign's size must coordinate with the architectural
element's size.
The sign should not over -crowd the architectural element,
the wall, or the sign area.
Buildings and building elements should not be used as
billboards.
❑
9.a
Wall signs must integrate with the building's architecture.
The sign placement should not obscure architectural
features or details, (such as cornices, windows, columns,
pilasters and paneling).
❑
9.d
An appropriate height for channel letters in a 30" high sign
band is 18 ".
This allows 6" of unoccupied space above and below the
letters.
4" of clear space above, below, and to the sides of a
channel letter sign is considered a minimum, with larger
clearances required for larger sign bands.
Degree of visibility, the distance from the Entrance
Corridor, and the architectural design of the building /area
REF
CHECKLIST ITEM
NOTES
will determine sign size, placement, and proportions.
❑
4.d
Lettering should be in proportion (font size and typeface
style) to the sign and the building.
Use of three typefaces or less.
Additional typefaces may be approved if they contribute to
a balanced /legible /unified sign design.
❑
9.e.iv
The width of the outline must be in proportion to the width
of the letter.
An outline width of 1/8" has been found to be an
appropriate sign dimension.
TRADEMARKS, CORPORATE LOGOS AND GRAPHICS
❑
4.f
The ARB may require that the color and scale of standard
templates for trademarks, service marks, corporate logos
and graphics be modified.
When used, trademarks, service marks, corporate logos
and /or graphics should be incorporated as an integral part
of the overall sign.
❑
S.a
External (or no) illumination is preferred for approved
graphics /logos;
❑
5.b
internal illumination may be considered for approval on a
case -by -case basis.
LIGHTING
❑
9.e.i
External (or no) illumination is preferred for wall signs.
❑
5.f
Any internal illumination is considered to contribute to
visual clutter and will be limited.
REF
CHECKLIST ITEM
NOTES
❑
5.c
Internal illumination design approval will be evaluated on
size, balance, complexity, and distance from the Entrance
Corridor.
•
9.e.iv
The backgrounds of such cabinet signs must be made
opaque (zero light transmission).
•
5.e
External illumination should be shielded and not create
glare.
All external light sources shall be white.
❑
9.ii
Sign lighting (external) should be shielded so that it
illuminates only face of the sign and does not shine beyond
the edge of the sign.
❑
9.iii
Channel letters with translucent faces must have no light
spilling outward from the top, bottom, sides or back.
Faces and returns of channel letters shall be opaque when
back -lit (halo -lit).
❑
9. iv
Cabinet signs shall have a non - illuminated background, or
an opaque (zero light transmission) background.
Cabinet signs shall be constructed such that no light spills
outward from the top, bottom, sides or back.
❑
5.g
All illumination shall be non - blinking.
❑
5.h
An exposed light source that forms the body of a sign,
(such as exposed neon signs), shall not be used in the
Entrance Corridors.
ARB ACTIONS
❑
If LED lighting is proposed the sign drawing must state
The level of illumination provided by the LED lights will
not exceed the illumination produced by a single stroke of
30 milliamp (ma) neon.
❑
Red acrylic #2283 has been determined to be an
REF
CHECKLIST ITEM
NOTES
inappropriate color for signs.
Pantone color match for 2283 is 485C.
Red #2793 has been approved as an acceptable substitute.
Pantone color match for 2793 is 187C.
ARB
Visual clutter resulting from adjacency, for example at the
Action
Hardee's locations, is a reasonable basis for not allowing
Memo:
illumination of the graphic.
5/7/12