HomeMy WebLinkAboutARB201400120 Checklist 2014-09-11RESUBMITTAL REVIEW CHECKLIST PROJECT #/NAME: AR113201400120, Red Robin Sign 10 -28 -2014 Original ARB Comment 10 -10 -2014 Review 10 -28 -2014 Review • The proposed Red Robin sign meets OK — done the definition of a roof sign because Sign now below roof level the structure it is attached to extends above the top of the wall of the structure. Roof signs are not permitted per Section 4.15.7 (c) 7 of the zoning ordinance. Revise the sign location so that it does not meet the definition of a roof sign. • Regarding the Red Robin sign, revise Yellow return: PMS 124 (OK) OK — no trim cap used the drawing to indicate the Pantone Red Robin Trim cap color not provided OK — Swoosh is Red PMS 187 — does not number for the yellow return and to Red Robin Swoosh Graphic: PMS for red illuminate indicate the trim cap /return color face not provided, trim cap /return color (with Pantone number). (with PMS #) not provided. Need to indicate if graphic shall internally illuminate. • Regarding the GOURMET The color and PMS # for trim cap /return not OK — trim cap /returns are black BURGERS sign, revise the drawing provided. to clearly indicate the trim cap /return color (with Pantone number). • Regarding the AND BREWS sign, "AND" with underscore: Black trim cap /return OK — trim cap /returns are black revise the drawing to clearly indicate (OK) the Pantone number for the yellow "BREWS ": trim cap /return color and face and to indicate the trim Pantone number not provided cap /return color (with Pantone number). • Revise all sign drawings to show the OK limits (top, bottom and sides) of the Red Robin: sign band where each sign is located. Sign Band: 18'6" (w) x T 2" (t) Include the overall dimensions, Sign 14'3 3/8" (w) x 66" (t) width and height, of each sign band. Unoccupied: 6" above; 14" below; 22.5" to each side • Revise all sign drawings, where LED OK — note on each page is proposed, to include the following note regarding the limitation on LED Original ARB Comment 10 -10 -2014 Review 10 -28 -2014 Review intensity: "The level of illumination provided by the LED lights will not exceed the illumination produced by a single stroke of 30 milliamp (ma) neon. " Issue: Sign approval cannot be provided OK — ARB approval of building permit granted until an ARB application for building (ARB 2014 -129) renovation has been received /reviewed and approved. SIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business ARB 201400120, Red Robin 09 -29 -2014 REF CHECKLIST ITEM NOTES TYPE • 9.b For internally illuminated signs, channel lettering OK — channel letters (mounted on a raceway or individual letters) is preferred to cabinet signs. • S.b When channel letters cannot be adequately accommodated, N/A internally illuminated cabinet signs may be considered. • 6 Reader boards are discouraged. None proposed MATERIALS • 4.c Materials used in the sign should complement the building OK being served by the sign. COLOR • 4.e Color for raceway- mounted channel letters, the raceway N/A — direct -mount letters shall match the wall color. Sign colors must be harmonious with each other. Red Robin: Face: Red Acrylic 2793 — OK Return: Yellow — PMS # not provided Trim cap /return: Not Provided GOURMET BURGERS: Face: White — OK Trim cap /return: Not Provided AND BREWS: Yellow — PMS# not provided Trim cap /return: Not Provided Sign colors must not clash with the site, when viewed in See above daylight and at night. Overly intense color, (such as dayglo or fluorescent See above colors), are prohibited. Use of three colors or less (black and white considered as OK colors) REF CHECKLIST ITEM NOTES Additional colors may be approved if they contribute to the sign balance /unity. SIZE, SCALE, PROPORTION, AND LOCATION • 4.b Signs may not exceed the size, height and setback Issue: Red Robin sign extends above the roof level requirements as outlined in Section 4.15 of the Albemarle County Zoning Ordinance (unless sign has a variance). • Appendix A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall Issue: need to show limits of sign band — show A.A area is a good working proportioning system for placing a overall dimensions of sign band. sign. • Appendix Color, form, surface pattern, shape, and disposition of OK A.A.4 elements and openings in an architectural design can affect our perception of scale and can impact the appearance of a sign on a building. • 9.d The wall sign's size must coordinate with the architectural OK element's size. The sign should not over -crowd the architectural element, OK the wall, or the sign area. Buildings and building elements should not be used as OK billboards. • 9.a Wall signs must integrate with the building's architecture. OK The sign placement should not obscure architectural OK features or details, (such as cornices, windows, columns, pilasters and paneling). • 9.d An appropriate height for channel letters in a 30" high sign N/A band is 18 ". REF CHECKLIST ITEM NOTES This allows 6" of unoccupied space above and below the letters. 4" of clear space above, below, and to the sides of a channel letter sign is considered a minimum, with larger clearances required for larger sign bands. Degree of visibility, the distance from the Entrance Corridor, and the architectural design of the building /area will determine sign size, placement, and proportions. X 4.d Lettering should be in proportion (font size and typeface Issue — drawing needs to show limits and overall style) to the sign and the building. dimensions of the sign band Use of three typefaces or less. OK —1 per sign Additional typefaces may be approved if they contribute to N/A a balanced /legible /unified sign design. X 9. e. iv The width of the outline must be in proportion to the width None proposed of the letter. An outline width of 1/8" has been found to be an appropriate sign dimension. TRADEMARKS, CORPORATE LOGOS AND GRAPHICS X 4.f The ARB may require that the color and scale of standard OK templates for trademarks, service marks, corporate logos and graphics be modified. When used, trademarks, service marks, corporate logos OK — Red Robin graphic has an integrated appearance and /or graphics should be incorporated as an integral part of the overall sign. X 5.a External (or no) illumination is preferred for approved OK — internal (channel letter) graphics /logos; X 5.b internal illumination may be considered for approval on a OK — internal (channel letter) case -by -case basis. REF CHECKLIST ITEM NOTES LIGHTING • 9.e.i External (or no) illumination is preferred for wall signs. OK — internal (channel letter) • 5.f Any internal illumination is considered to contribute to OK visual clutter and will be limited. • 5.c Internal illumination design approval will be evaluated on OK size, balance, complexity, and distance from the Entrance Corridor. • 9.e.iv The backgrounds of such cabinet signs must be made None proposed opaque (zero light transmission). • 5.e External illumination should be shielded and not create None proposed glare. All external light sources shall be white. • 93i Sign lighting (external) should be shielded so that it illuminates only face of the sign and does not shine beyond the edge of the sign. • 93ii Channel letters with translucent faces must have no light OK spilling outward from the top, bottom, sides or back. Faces and returns of channel letters shall be opaque when Not proposed — face lit back -lit (halo -lit). • 9. iv Cabinet signs shall have a non - illuminated background, or None proposed an opaque (zero light transmission) background. Cabinet signs shall be constructed such that no light spills outward from the top, bottom, sides or back. • 5.g All illumination shall be non - blinking. None proposed • 5.h An exposed light source that forms the body of a sign, None proposed (such as exposed neon signs), shall not be used in the Entrance Corridors. ARB ACTIONS X I If LED lighting is proposed the sign drawing must state Issue — note missing REF CHECKLIST ITEM NOTES The level of illumination provided by the LED lights will not exceed the illumination produced by a single stroke of 30 milliamp (ma) neon. X Red acrylic #2283 has been determined to be an OK — Red Acrylic 2793 proposed inappropriate color for signs. Pantone color match for 2283 is 485C. Red #2793 has been approved as an acceptable substitute. Pantone color match for 2793 is 187C. X ARB Visual clutter resulting from adjacency, for example at the OK Action Hardee's locations, is a reasonable basis for not allowing Memo: illumination of the graphic. 5/7/12 Completeness Check for Signs Project #/Name: _ARB201400120, Red Robin Sign Date Received at County: _09/10/2014 Date Received in Design Planning: _09/10/2014 Date of Checklist Check: _09/10/2014_ Assigned to /Date: _09/102014 FEES 3. ARB Review —Will the permanent sign(s) be constructed in an Entrance Corridor? (Seethe Entrance Corridor map in the Sign Permit Application packet for a list of Entrance Corridors.) ❑ Yes (This sign will be constructed in an Entrance Corridor and it does not meet the conditions of a $120.00 Comprehensive Sign Review. See ARB requirements next pages.) OK - Paid ❑ Yes (This sign will be constructed in an Entrance Corridor and it does meet the conditions of a Waive Fee Comprehensive Sign Review. See ARB requirements next pages) ❑ No (This sign will not be constructed in an Entrance Corridor) $ 0.00 FEE TOTAL (Please add all the amounts checked in sections I — 3): $ FREESTANDING SIGNS None proposed A. Submittal Requirements ❑ Site plan or latest approved plat showing, to scale, the proposed location of the sign(s) with dimensions. ❑ Distance from the sign to the property lines and/or edge of the VDOT right -of -way. ❑ If the sign will be located in an easement, a letter of approval from the easement holder will be required. ❑ A to -scale color illustration of the proposed sign showing ❑ Dimensions of the sign, including overall height from the ground; cabinet size, length, width and depth; base size, etc. (Be sure to also include these dimensions on the diagrams provided in the Sign Permit Application packet.) ❑ Proposed lettering and/or graphics in their proposed location. ❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor, also provide a color illustration of the front and side elevations of the sign showing: • If internally illuminated, indicate which areas of the sign are opaque and which are illuminated. Internally illuminated cabinet signs must have opaque backgrounds. (Opaque materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be detected nor can objects be seen through it.) • Identification of proposed materials and colors. Include standard color id numbers (Pantone, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, base, faces, trim caps, returns, etc. • Provide accurate physical samples of all colors proposed, preferably in the material proposed. (Paint chips that accurately reflect the proposed colors are acceptable.) • Provide a site plan showing proposed landscaping around the sign, including botanical names and planting sizes. • Additional submittal materials may be required if review by the Architectural Review Board is necessary. (The applicant will be notified if this requirement applies.) WALL SIGNS ❑ A drawing, to scale, showing dimensions of the sign (length, height, depth). OK ❑ Elevation drawing(s) or modified photograph of the entire building, to scale and in color, showing ❑ The sign location on the building, sign height above grade, and the length of building frontage. (Be sure to also include these dimensions on the diagrams provided in Appendix B) OK ❑ Sign lettering and /or graphics in their proposed location. OK ❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor also provide a color illustration of the front and side elevations of the sign showing: • Indication of sign type (channel letters, cabinet, panel, etc.). OK • Indicate on the drawings the proposed materials and colors. Include standard color identification numbers (Pantone, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, faces, trim caps, etc. For channel letter signs, indicate on the drawing that the raceway color shall match the color of the wall to which the raceway is attached. Missing • Provide accurate physical samples of all colors proposed in the sign, preferably in the material proposed. (Paint chips that accurately reflect the proposed colors are acceptable.) Missing • Location of proposed light fixtures and manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17. OK o For internally illuminated signs, indicate which areas of the sign are opaque and which are illuminated. (Opaque materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be detected nor can objects be seen through it.) Missing ILLUMINATION REQUIREMENTS ❑ The location of proposed light fixtures identified on a plan and/or elevation OK ❑ Manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17 of the Zoning Ordinance. NOTES: