HomeMy WebLinkAboutARB201400120 Checklist 2014-09-11RESUBMITTAL REVIEW CHECKLIST
PROJECT #/NAME: AR113201400120, Red Robin Sign
10 -28 -2014
Original ARB Comment
10 -10 -2014 Review
10 -28 -2014 Review
•
The proposed Red Robin sign meets
OK — done
the definition of a roof sign because
Sign now below roof level
the structure it is attached to extends
above the top of the wall of the
structure. Roof signs are not
permitted per Section 4.15.7 (c) 7 of
the zoning ordinance. Revise the
sign location so that it does not meet
the definition of a roof sign.
•
Regarding the Red Robin sign, revise
Yellow return: PMS 124 (OK)
OK — no trim cap used
the drawing to indicate the Pantone
Red Robin Trim cap color not provided
OK — Swoosh is Red PMS 187 — does not
number for the yellow return and to
Red Robin Swoosh Graphic: PMS for red
illuminate
indicate the trim cap /return color
face not provided, trim cap /return color
(with Pantone number).
(with PMS #) not provided. Need to indicate
if graphic shall internally illuminate.
•
Regarding the GOURMET
The color and PMS # for trim cap /return not
OK — trim cap /returns are black
BURGERS sign, revise the drawing
provided.
to clearly indicate the trim cap /return
color (with Pantone number).
•
Regarding the AND BREWS sign,
"AND" with underscore: Black trim cap /return
OK — trim cap /returns are black
revise the drawing to clearly indicate
(OK)
the Pantone number for the yellow
"BREWS ": trim cap /return color and
face and to indicate the trim
Pantone number not provided
cap /return color (with Pantone
number).
•
Revise all sign drawings to show the
OK
limits (top, bottom and sides) of the
Red Robin:
sign band where each sign is located.
Sign Band: 18'6" (w) x T 2" (t)
Include the overall dimensions,
Sign 14'3 3/8" (w) x 66" (t)
width and height, of each sign band.
Unoccupied: 6" above; 14" below; 22.5" to
each side
•
Revise all sign drawings, where LED
OK — note on each page
is proposed, to include the following
note regarding the limitation on LED
Original ARB Comment
10 -10 -2014 Review
10 -28 -2014 Review
intensity:
"The level of illumination
provided by the LED
lights will not exceed the
illumination produced by
a single stroke of 30
milliamp (ma) neon. "
Issue: Sign approval cannot be provided
OK — ARB approval of building permit granted
until an ARB application for building
(ARB 2014 -129)
renovation has been received /reviewed and
approved.
SIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business
ARB 201400120, Red Robin
09 -29 -2014
REF
CHECKLIST ITEM
NOTES
TYPE
•
9.b
For internally illuminated signs, channel lettering
OK — channel letters
(mounted on a raceway or individual letters) is preferred to
cabinet signs.
•
S.b
When channel letters cannot be adequately accommodated,
N/A
internally illuminated cabinet signs may be considered.
•
6
Reader boards are discouraged.
None proposed
MATERIALS
•
4.c
Materials used in the sign should complement the building
OK
being served by the sign.
COLOR
•
4.e
Color for raceway- mounted channel letters, the raceway
N/A — direct -mount letters
shall match the wall color.
Sign colors must be harmonious with each other.
Red Robin:
Face: Red Acrylic 2793 — OK
Return: Yellow — PMS # not provided
Trim cap /return: Not Provided
GOURMET BURGERS:
Face: White — OK
Trim cap /return: Not Provided
AND BREWS: Yellow — PMS# not provided
Trim cap /return: Not Provided
Sign colors must not clash with the site, when viewed in
See above
daylight and at night.
Overly intense color, (such as dayglo or fluorescent
See above
colors), are prohibited.
Use of three colors or less (black and white considered as
OK
colors)
REF
CHECKLIST ITEM
NOTES
Additional colors may be approved if they contribute to the
sign balance /unity.
SIZE, SCALE, PROPORTION, AND LOCATION
•
4.b
Signs may not exceed the size, height and setback
Issue: Red Robin sign extends above the roof level
requirements as outlined in Section 4.15 of the Albemarle
County Zoning Ordinance (unless sign has a variance).
•
Appendix
A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall
Issue: need to show limits of sign band — show
A.A
area is a good working proportioning system for placing a
overall dimensions of sign band.
sign.
•
Appendix
Color, form, surface pattern, shape, and disposition of
OK
A.A.4
elements and openings in an architectural design can affect
our perception of scale and can impact the appearance of a
sign on a building.
•
9.d
The wall sign's size must coordinate with the architectural
OK
element's size.
The sign should not over -crowd the architectural element,
OK
the wall, or the sign area.
Buildings and building elements should not be used as
OK
billboards.
•
9.a
Wall signs must integrate with the building's architecture.
OK
The sign placement should not obscure architectural
OK
features or details, (such as cornices, windows, columns,
pilasters and paneling).
•
9.d
An appropriate height for channel letters in a 30" high sign
N/A
band is 18 ".
REF
CHECKLIST ITEM
NOTES
This allows 6" of unoccupied space above and below the
letters.
4" of clear space above, below, and to the sides of a
channel letter sign is considered a minimum, with larger
clearances required for larger sign bands.
Degree of visibility, the distance from the Entrance
Corridor, and the architectural design of the building /area
will determine sign size, placement, and proportions.
X
4.d
Lettering should be in proportion (font size and typeface
Issue — drawing needs to show limits and overall
style) to the sign and the building.
dimensions of the sign band
Use of three typefaces or less.
OK —1 per sign
Additional typefaces may be approved if they contribute to
N/A
a balanced /legible /unified sign design.
X
9. e. iv
The width of the outline must be in proportion to the width
None proposed
of the letter.
An outline width of 1/8" has been found to be an
appropriate sign dimension.
TRADEMARKS, CORPORATE LOGOS AND GRAPHICS
X
4.f
The ARB may require that the color and scale of standard
OK
templates for trademarks, service marks, corporate logos
and graphics be modified.
When used, trademarks, service marks, corporate logos
OK — Red Robin graphic has an integrated appearance
and /or graphics should be incorporated as an integral part
of the overall sign.
X
5.a
External (or no) illumination is preferred for approved
OK — internal (channel letter)
graphics /logos;
X
5.b
internal illumination may be considered for approval on a
OK — internal (channel letter)
case -by -case basis.
REF
CHECKLIST ITEM
NOTES
LIGHTING
•
9.e.i
External (or no) illumination is preferred for wall signs.
OK — internal (channel letter)
•
5.f
Any internal illumination is considered to contribute to
OK
visual clutter and will be limited.
•
5.c
Internal illumination design approval will be evaluated on
OK
size, balance, complexity, and distance from the Entrance
Corridor.
•
9.e.iv
The backgrounds of such cabinet signs must be made
None proposed
opaque (zero light transmission).
•
5.e
External illumination should be shielded and not create
None proposed
glare.
All external light sources shall be white.
•
93i
Sign lighting (external) should be shielded so that it
illuminates only face of the sign and does not shine beyond
the edge of the sign.
•
93ii
Channel letters with translucent faces must have no light
OK
spilling outward from the top, bottom, sides or back.
Faces and returns of channel letters shall be opaque when
Not proposed — face lit
back -lit (halo -lit).
•
9. iv
Cabinet signs shall have a non - illuminated background, or
None proposed
an opaque (zero light transmission) background.
Cabinet signs shall be constructed such that no light spills
outward from the top, bottom, sides or back.
•
5.g
All illumination shall be non - blinking.
None proposed
•
5.h
An exposed light source that forms the body of a sign,
None proposed
(such as exposed neon signs), shall not be used in the
Entrance Corridors.
ARB ACTIONS
X
I If LED lighting is proposed the sign drawing must state
Issue — note missing
REF
CHECKLIST ITEM
NOTES
The level of illumination provided by the LED lights will
not exceed the illumination produced by a single stroke of
30 milliamp (ma) neon.
X
Red acrylic #2283 has been determined to be an
OK — Red Acrylic 2793 proposed
inappropriate color for signs.
Pantone color match for 2283 is 485C.
Red #2793 has been approved as an acceptable substitute.
Pantone color match for 2793 is 187C.
X
ARB
Visual clutter resulting from adjacency, for example at the
OK
Action
Hardee's locations, is a reasonable basis for not allowing
Memo:
illumination of the graphic.
5/7/12
Completeness Check for Signs
Project #/Name: _ARB201400120, Red Robin Sign
Date Received at County: _09/10/2014
Date Received in Design Planning: _09/10/2014
Date of Checklist Check: _09/10/2014_ Assigned to /Date: _09/102014
FEES
3. ARB Review —Will the permanent sign(s) be constructed in an Entrance Corridor?
(Seethe Entrance Corridor map in the Sign Permit Application packet for a list of Entrance Corridors.)
❑ Yes (This sign will be constructed in an Entrance Corridor and it does not meet the conditions of a $120.00
Comprehensive Sign Review. See ARB requirements next pages.) OK - Paid
❑ Yes (This sign will be constructed in an Entrance Corridor and it does meet the conditions of a Waive Fee
Comprehensive Sign Review. See ARB requirements next pages)
❑ No (This sign will not be constructed in an Entrance Corridor) $ 0.00
FEE TOTAL (Please add all the amounts checked in sections I — 3): $
FREESTANDING SIGNS None proposed
A. Submittal Requirements
❑ Site plan or latest approved plat showing, to scale, the proposed location of the sign(s) with dimensions.
❑ Distance from the sign to the property lines and/or edge of the VDOT right -of -way.
❑ If the sign will be located in an easement, a letter of approval from the easement holder will be required.
❑ A to -scale color illustration of the proposed sign showing
❑ Dimensions of the sign, including overall height from the ground; cabinet size, length, width and depth; base
size, etc. (Be sure to also include these dimensions on the diagrams provided in the Sign Permit Application packet.)
❑ Proposed lettering and/or graphics in their proposed location.
❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor, also provide a color
illustration of the front and side elevations of the sign showing:
• If internally illuminated, indicate which areas of the sign are opaque and which are illuminated. Internally
illuminated cabinet signs must have opaque backgrounds. (Opaque materials don't allow light to pass through.
When lit only from behind, the color of an opaque material cannot be detected nor can objects be seen through it.)
• Identification of proposed materials and colors. Include standard color id numbers (Pantone, Benjamin Moore,
Acrylic, etc.) for all materials, text, graphics, base, faces, trim caps, returns, etc.
• Provide accurate physical samples of all colors proposed, preferably in the material proposed. (Paint chips that
accurately reflect the proposed colors are acceptable.)
• Provide a site plan showing proposed landscaping around the sign, including botanical names and planting sizes.
• Additional submittal materials may be required if review by the Architectural Review Board is necessary. (The
applicant will be notified if this requirement applies.)
WALL SIGNS
❑ A drawing, to scale, showing dimensions of the sign (length, height, depth). OK
❑ Elevation drawing(s) or modified photograph of the entire building, to scale and in color, showing
❑ The sign location on the building, sign height above grade, and the length of building frontage. (Be sure to also
include these dimensions on the diagrams provided in Appendix B) OK
❑ Sign lettering and /or graphics in their proposed location. OK
❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor also provide a color
illustration of the front and side elevations of the sign showing:
• Indication of sign type (channel letters, cabinet, panel, etc.). OK
• Indicate on the drawings the proposed materials and colors. Include standard color identification numbers
(Pantone, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, faces, trim caps, etc. For channel letter
signs, indicate on the drawing that the raceway color shall match the color of the wall to which the raceway is
attached. Missing
• Provide accurate physical samples of all colors proposed in the sign, preferably in the material proposed. (Paint
chips that accurately reflect the proposed colors are acceptable.) Missing
• Location of proposed light fixtures and manufacturer cut sheets describing illumination type, intensity, style,
shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17. OK
o For internally illuminated signs, indicate which areas of the sign are opaque and which are illuminated. (Opaque
materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be
detected nor can objects be seen through it.) Missing
ILLUMINATION REQUIREMENTS
❑ The location of proposed light fixtures identified on a plan and/or elevation OK
❑ Manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must
meet ordinance requirements as outlined in Section 4.17 of the Zoning Ordinance.
NOTES: