HomeMy WebLinkAboutARB201400119 Checklist 2014-09-02RESUBMITTAL REVIEW CHECKLIST
PROJECT #/NAME: ARB 201400119, Floor Fashions Sign
10 -01 -14
Original ARB comment
10 -01 -14 Review
10 -07 -14 Review
X
Revise the sign drawing to indicate the Pantone colors for
the sign cabinet and sign structure (pole, cabinet frame).
Issue: PMS colors for sign cabinet
not provided
OK — done
Logo /text: Green PMS 342
X
Revise the sign drawing to indicate the total height of the
sign.
OK — noted on drawing
12' tall
X
Revise the sign drawing to include the following note
regarding LED intensity:
"The level of illumination provided by the LED lights will
not exceed the illumination produced by a single stroke of
30 milliamp (ma) neon."
OK — note on drawing
RESUBMITTAL REVIEW CHECKLIST
PROJECT #/NAME: ARB 201400119, Floor Fashions Sign
10 -01 -14
Original ARB comment
10 -01 -14 Review
X
Revise the sign drawing to indicate the Pantone colors for
the sign cabinet and sin structure (pole, cabinet frame).
Issue: PMS colors for sign cabinet not provided
X
Revise the sign drawing to indicate the total height of the
sign.
OK — noted on drawing
12' tall
X
Revise the sign drawing to include the following note
regarding LED intensity:
"The level of illumination provided by the LED lights will
not exceed the illumination produced by a single stroke of
30 milliamp (ma) neon."
OK — note on drawing
SIGN REVIEW CHECKLIST WITH REFERENCES — Freestanding Signs
ARB 201400119, Floor Fashions Sign
Updated: 9 -30 -2010
REF
CHECKLIST ITEM
NOTES
TYPE
•
8.a
Monument signs are preferred to pole- mounted signs.
N/A — existing pole
Pole signs may be considered if existing site conditions rule
out the ability to use a monument sign, and only when the pole
is in proportion to the sign cabinet or panel.
See above
MATERIALS
•
8.b
Materials used in both the sign and support structures should
be complementary.
OK
They should also support the aesthetics of the
building/complex being served by the sign.
N/A — reuse of existing pole
•
8.b
It is preferred that the base material match one of the primary
building materials
N/A
unless the sign design represents itself as a freestanding
element complementing the building.
N/A
COLORS
•
4.e
Colors must be harmonious with each other.
Issue: Pantone colors not indicated
Colors must not clash with other elements on the site, both
when viewed in daylight and at night.
Issue: Pantone colors not indicated
Overly intense color, (such as dayglo or fluorescent colors),
are prohibited.
Issue: Pantone colors not indicated
Use of three colors or less
Black and white are colors.
OK — 3 proposed
Updated: 9 -30 -2010
Updated: 9 -30 -2010
REF
CHECKLIST ITEM
NOTES
Additional colors may be approved if they contribute to a
balanced/unified sign design.
•
9.c
For raceway- mounted channel letters, raceways shall match
N/A
the wall color.
LANDSCAPING
•
8.d
Use ground cover, shrubs and /or trees to integrate freestanding
N/A — reuse of existing sign pole — existing
signs into the overall site landscape.
plantings
Use plants from the Albemarle County Recommended Plants
N/A
List.
SCALE AND SIZE
•
4.b
Signs may not exceed the size, height and setback
OK — per S. Wright
requirements as outlined in Section 4.15 of the Albemarle
32 sq ft proposed - 32 sq ft max allowed
County Zoning Ordinance (unless the sign has received a
CLE 2014 -71
variance).
Issue: Proposed sign height not indicated on the
drawing
•
8.c
The structure of a monument sign shall not overwhelm the
OK
sign.
The structure and the sign that it supports must be in
OK
proportion to each other.
SIGN LETTERING AND TYPEFACE
•
4.d
Lettering should be in proportion (font size and typeface style)
OK
to the sign and the building.
Use of three typefaces or less.
OK-4
Additional typeface — limited use
Additional typefaces may be approved if they contribute to a
See above
balanced, legible, unified sign design.
Updated: 9 -30 -2010
Updated: 9 -30 -2010
REF
CHECKLIST ITEM
NOTES
X
8.e.iv
If outlines of letters are proposed, the outline width must be in
None proposed
proportion to the letter width.
An outline width of 1/8" is the appropriate sign dimension.
None proposed
TRADEMARKS, CORPORATE LOGOS, AND GRAPHICS
X
4.f
The ARB may require that the color and scale of standard
OK
templates for trademarks, service marks, corporate logos and
graphics be modified.
When used, trademarks, service marks, corporate logos and /or
OK — graphics have an integrated appearance with
graphics should be incorporated as an integral part of the
the overall sign.
overall sign.
LIGHTING
X
8.e.i
External illumination (or no illumination) is preferred for
OK — internal (cabinet)
freestanding signs.
X
S.f
Any internal illumination is considered to contribute to visual
OK — internal
clutter and will be limited.
The design will be evaluated for size, balance, complexity, and
distance from and relationship to the Entrance Corridor.
X
5.e
External Illumination should be shielded and not create glare.
None proposed
Lighting should be aimed so as not to project illumination
N/A
beyond the sign.
All external light sources shall be white.
N/A
X
8. e. ii
Ground mounted lighting should be shielded by landscaping so
N/A
that it is not visible from any adjacent property or right -of-
way.
Updated: 9 -30 -2010
Updated: 9 -30 -2010
REF
CHECKLIST ITEM
NOTES
X
S.h
An exposed light source that forms the body of a sign, (such as
None proposed
exposed neon signs), shall not be used.
X
5.;
All illumination shall be non - blinking.
None proposed
X
5.c
External illumination (or no illumination) is preferred for
OK — internal — opaque background — graphics not
approved graphics /logos;
to illuminate
internal illumination may be considered for approval.
OK — see above
X
8. e. iv
Cabinet signs shall have a non - illuminated background, or an
OK — noted on drawing
opaque (zero light transmission) background.
Cabinet signs shall be constructed such that no light spills
OK
outward from the top, bottom, sides or back.
X
8. e. iii
Channel letters (although not likely appropriate for
None proposed
freestanding signs) with translucent faces shall be constructed
such that no light spills outward from the top, bottom, sides or
back.
If back -lit (halo -lit), the faces and returns of channel letters
N/A
shall be opaque.
ARB ACTIONS
X
(ARB
Billboards are inappropriate for the Entrance Corridors.
None proposed
Action
Memo:
1/19/10)
No refacing design (no combination of colors, images, text and
layout) will make the billboard an appropriate appearance.
Existing billboards may not increase in size and may not
include modifications beyond the existing sign surface.
Updated: 9 -30 -2010
Updated: 9 -30 -2010
REF
CHECKLIST ITEM
NOTES
No new illumination of any kind may be added to the
billboard.
•
(ARB
Reader boards shall have an opaque background.
None proposed
Action
Memo:
1/19/10)
Only the letters may be illuminated, but illumination is not
required.
Reader boards shall not exceed 40% of the size of the overall
sign face.
The background color of the reader board shall be black or
some other color already on the sign face.
Construction of the reader board shall be integral with the
main sign.
The track holding the letters shall have minimal visual impact.
•
(ARB
Synthetic stucco is acceptable for signs if mounted on a solid
None proposed
Action
surface such as concrete block and if limited to use as a flat
Memo:
surface as a background for lettering.
5/4/09)
Styrofoam backing is not acceptable.
X
Red acrylic #2283 has been determined to be an inappropriate
No red color proposed
color for signs.
Pantone color match for 2283 is 485C.
Red #2793 has been approved as an acceptable substitute.
Updated: 9 -30 -2010
Updated: 9 -30 -2010
REF
CHECKLIST ITEM
NOTES
Pantone color match for 2793 is 187C.
X
(ARB
Scale, location, proximity to existing building(s), quality of
N/A — existing planting (to remain)
Action
sign materials, and sign height and other pre- existing
Memo:
conditions determine how much planting is required at the
10/5/09)
base of the freestanding sign.
X
If LED lighting is proposed the sign drawing must state The
Issue — LED proposed and note missing
level of illumination provided by the LED lights will not
exceed the illumination produced by a single stroke of 30
milliamp (ma) neon.
X
Internal LED for the gas pricing: Daytime intensity limited to
N/A
70% of maximum intensity; Nighttime intensity limited to
16% of maximum intensity with automatic dimming at dusk.
X
ARB
Visual clutter resulting from adjacency, for example at the
N/A — graphic not to illuminate
Action
Hardee's locations, is a reasonable basis for not allowing
Memo:
illumination of the graphic.
5/7/12
Updated: 9 -30 -2010
Completeness Check for Signs
Project #/Name: _ARB201400119, Floor Fashions Sign_
Date Received at County: _08/29/2014
Date Received in Design Planning: _ 09/02/2014
Date of Checklist Check: _09/02/2014_ Assigned to /Date: _09/02/2014
FEES
3. ARB Review — Will the permanent sign(s) be constructed in an Entrance Corridor?
(Seethe Entrance Corridor map in the Sign Permit Application packet for a list of Entrance Corridors.)
❑ Yes (This sign will be constructed in an Entrance Corridor and it does not meet the conditions of a $120.00
Comprehensive Sign Review. See ARB requirements next pages) OK - Paid
❑ Yes (This sign will be constructed in an Entrance Corridor and it does meet the conditions of a Waive Fee
Comprehensive Sign Review. See ARB requirements next pages)
❑ No (This sign will not be constructed in an Entrance Corridor) $ 0.00
FEE TOTAL (Please add all the amounts checked in sections I — 3): $
FREESTANDING SIGNS
A. Submittal Requirements
❑ Site plan or latest approved plat showing, to scale, the proposed location of the sign(s) with dimensions. N/A -
Existing
❑ Distance from the sign to the property lines and/or edge of the VDOT right -of -way. N/A - Existing
❑ If the sign will be located in an easement, a letter of approval from the easement holder will be required. N/A -
Existing
❑ A to -scale color illustration of the proposed sign showing
❑ Dimensions of the sign, including overall height from the ground; cabinet size, length, width and depth; base
size, etc. (Be sure to also include these dimensions on the diagrams provided in the Sign Permit Application packet.) Height
of sign missing
❑ Proposed lettering and/or graphics in their proposed location. OK
❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor, also provide a color
illustration of the front and side elevations of the sign showing:
• If internally illuminated, indicate which areas of the sign are opaque and which are illuminated. Internally
illuminated cabinet signs must have opaque backgrounds. (Opaque materials don't allow light to pass through.
When lit only from behind, the color of an opaque material cannot be detected nor can objects be seen through it.)
OK
• Identification of proposed materials and colors. Include standard color id numbers (Pantone, Benjamin Moore,
Acrylic, etc.) for all materials, text, graphics, base, faces, trim caps, returns, etc. Missing
• Provide accurate physical samples of all colors proposed, preferably in the material proposed. (Paint chips that
accurately reflect the proposed colors are acceptable.) Missing
• Provide a site plan showing proposed landscaping around the sign, including botanical names and planting sizes.
N/A — existing pole and planting
• Additional submittal materials may be required if review by the Architectural Review Board is necessary. (The
applicant will be notified if this requirement applies.)
WALL SIGNS None Proposed
❑ A drawing, to scale, showing dimensions of the sign (length, height, depth).
❑ Elevation drawing(s) or modified photograph of the entire building, to scale and in color, showing
❑ The sign location on the building, sign height above grade, and the length of building frontage. (Be sure to also
include these dimensions on the diagrams provided in Appendix B)
❑ Sign lettering and /or graphics in their proposed location.
❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor also provide a color
illustration of the front and side elevations of the sign showing:
• Indication of sign type (channel letters, cabinet, panel, etc.).
• Indicate on the drawings the proposed materials and colors. Include standard color identification numbers
(Pantone, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, faces, trim caps, etc. For channel letter
signs, indicate on the drawing that the raceway color shall match the color of the wall to which the raceway is
attached.
• Provide accurate physical samples of all colors proposed in the sign, preferably in the material proposed. (Paint
chips that accurately reflect the proposed colors are acceptable.)
• Location of proposed light fixtures and manufacturer cut sheets describing illumination type, intensity, style,
shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17.
o For internally illuminated signs, indicate which areas of the sign are opaque and which are illuminated. (Opaque
materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be
detected nor can objects be seen through it.)
ILLUMINATION REQUIREMENTS
❑ The location of proposed light fixtures identified on a plan and/or elevation OK
❑ Manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must
meet ordinance requirements as outlined in Section 4.17 of the Zoning Ordinance.
NOTES: