HomeMy WebLinkAboutARB201400118 Checklist 2014-08-29RESUBMITTAL REVIEW CHECKLIST
PROJECT #/NAME: ARB 201400118, Rocksalt Sign
09/25/2014
ARB COMMENT (original review)
09/16/2014 Review
09/25/2014 Review
X
1. Sign Drawing Label:
OK - done
a. Revise sign drawing label for "New
Proposed East Elevation" to read "New
Proposed Northeast (front) Elevation ".
b. Revise the sign drawing label for "New
Proposed North Elevation" to read "New
Proposed Northwest (side) Elevation ".
X
2. Sign Colors:
OK — done
a. Revise the sign drawing to indicate the
Pantone color number for the proposed
Duranodic Bronze letter face. Approved
CSC allow for Warm Gray 1 — 11.
X
3. Sign Lighting:
OK
a. Revise the sign drawing to include:
Drawing shows use of 19 watt (1,300
i. A note indicating the wall signs are
lumens) bulbs
to be externally illuminated,
assuming they are. OK - done
ii. A note indicating the manufacturer
and model number of the light
fixture. OK - done
iii. The following note: "The light
fixture is to be shielded and
positioned so that it illuminates
only the face of the sign." OK -
done
iv. The location of the proposed wall
light fixtures. OK -done
v. The following note if LED
illumination is proposed: "The
level of illumination provided by
the LED lights will not exceed
the illumination produced by a
ARB COMMENT (original review)
09/16/2014 Review
09/25/2014 Review
single stroke of 30 milliamp
(ma) neon. Issues: LED does not
come in 35 watts
b. Revise the lighting cutsheet provided by
indicating all of the options chosen
including model number, fixture finish,
light source (bulb type /wattage) and
mounting type; black and bronze are
considered appropriate colors. Issues:
bulb type not provided.
http: / /www. base ite. com /pdfs /catalogs
/baselite- sign - lights - catalog. pdf
RESUBMITTAL REVIEW CHECKLIST
PROJECT #/NAME: ARB 201400118, Rocksalt Sign
09/16/2014
ARB COMMENT (original review)
09/16/2014 Review
X
1. Sign Drawing Label:
OK - done
a. Revise sign drawing label for "New
Proposed East Elevation" to read "New
Proposed Northeast (front) Elevation ".
b. Revise the sign drawing label for "New
Proposed North Elevation" to read "New
Proposed Northwest (side) Elevation ".
X
2. Sign Colors:
OK — done
a. Revise the sign drawing to indicate the
Pantone color number for the proposed
Duranodic Bronze letter face. Approved
CSC allow for Warm Gray 1 — 11.
X
3. Sign Lighting:
a. Revise the sign drawing to include:
i. A note indicating the wall signs are
to be externally illuminated,
assuming they are. OK - done
ii. A note indicating the manufacturer
and model number of the light
fixture. OK - done
iii. The following note: "The light
fixture is to be shielded and
positioned so that it illuminates
only the face of the sign." OK -
done
iv. The location of the proposed wall
light fixtures. OK -done
v. The following note if LED
illumination is proposed: "The
level of illumination provided by
the LED lights will not exceed
the illumination produced by a
ARB COMMENT (original review)
09/16/2014 Review
single stroke of 30 milliamp
(ma) neon. Issues: LED does not
come in 35 watts
b. Revise the lighting cutsheet provided by
indicating all of the options chosen
including model number, fixture finish,
light source (bulb type /wattage) and
mounting type; black and bronze are
considered appropriate colors. Issues:
bulb type not provided.
http: / /www. baselite.com /pdfs /catalogs /baselite- sign- lights-
catalog. pdf
SIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business
ARB 201400118, Rocksalt Sign
09 -10 -2014
ARB 201400118, Rocksalt Sign
REF
CHECKLIST ITEM
NOTES
TYPE
•
9.b
For internally illuminated signs, channel lettering
OK — individual (not internally illuminated) letters
(mounted on a raceway or individual letters) is preferred to
cabinet signs.
•
5.b
When channel letters cannot be adequately accommodated,
N/A
internally illuminated cabinet signs may be considered.
•
6
Reader boards are discouraged.
None proposed
MATERIALS
•
4.c
Materials used in the sign should complement the building
OK
being served by the sign.
COLOR
•
4.e
Color for raceway- mounted channel letters, the raceway
N/A — direct -mount
shall match the wall color.
Sign colors must be harmonious with each other.
Issue: PMS# for Duranodic bronze color not
provided. CSC require it match PMS Warm Gray 1
-11
Sign colors must not clash with the site, when viewed in
OK
daylight and at night.
Overly intense color, (such as dayglo or fluorescent
None proposed
colors), are prohibited.
Use of three colors or less (black and white considered as
OK-2
colors)
Additional colors may be approved if they contribute to the
sign balance /unity.
SIZE, SCALE, PROPORTION, AND LOCATION
•
4.b
I Signs may not exceed the size, height and setback
OK — per S. Wright
REF
CHECKLIST ITEM
NOTES
requirements as outlined in Section 4.15 of the Albemarle
2 signs - 14.1 sq ft and 3.1 sq ft = 17.2 sq ft proposed -
County Zoning Ordinance (unless sign has a variance).
69 sq ft max allowed
CLE2014 -72
•
Appendix
A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall
OK
A.A
area is a good working proportioning system for placing a
sign.
•
Appendix
Color, form, surface pattern, shape, and disposition of
OK
A.A.4
elements and openings in an architectural design can affect
our perception of scale and can impact the appearance of a
sign on a building.
•
9.d
The wall sign's size must coordinate with the architectural
OK — in approved location
element's size.
The sign should not over -crowd the architectural element,
OK
the wall, or the sign area.
Buildings and building elements should not be used as
OK
billboards.
•
9.a
Wall signs must integrate with the building's architecture.
OK — in approved location
The sign placement should not obscure architectural
OK
features or details, (such as cornices, windows, columns,
pilasters and paneling).
•
9.d
An appropriate height for channel letters in a 30" high sign
N/A
band is 18 ".
This allows 6" of unoccupied space above and below the
N/A
letters.
4" of clear space above, below, and to the sides of a
N/A
channel letter sign is considered a minimum, with larger
clearances required for larger sign bands.
REF
CHECKLIST ITEM
NOTES
Degree of visibility, the distance from the Entrance
OK
Corridor, and the architectural design of the building /area
will determine sign size, placement, and proportions.
•
4.d
Lettering should be in proportion (font size and typeface
OK
style) to the sign and the building.
Use of three typefaces or less.
OK
Additional typefaces may be approved if they contribute to
N/A
a balanced /legible /unified sign design.
•
9. e. iv
The width of the outline must be in proportion to the width
OK
of the letter.
CSC do not allow for outlines; however impact
sufficiently reduced by distance from EC and use of
external illumination (versus internal).
An outline width of 1/8" has been found to be an
OK
appropriate sign dimension.
TRADEMARKS, CORPORATE LOGOS AND GRAPHICS
•
4.f
The ARB may require that the color and scale of standard
None proposed
templates for trademarks, service marks, corporate logos
and graphics be modified.
When used, trademarks, service marks, corporate logos
N/A
and /or graphics should be incorporated as an integral part
of the overall sign.
•
5.a
External (or no) illumination is preferred for approved
N/A
graphics /logos;
•
5.b
internal illumination may be considered for approval on a
N/A
case -by -case basis.
LIGHTING
•
9.e.i External (or no) illumination is preferred for wall signs.
Issues:
• External lighting proposed — cutsheet provided —
chosen options not indicated — fixture arm not
provided.
REF
CHECKLIST ITEM
NOTES
• Location of fixtures on wall not provided.
X
S.f
Any internal illumination is considered to contribute to
None proposed
visual clutter and will be limited.
X
5.c
Internal illumination design approval will be evaluated on
N/A
size, balance, complexity, and distance from the Entrance
Corridor.
X
9. e. iv
The backgrounds of such cabinet signs must be made
None proposed
opaque (zero light transmission).
X
5.e
External illumination should be shielded and not create
None proposed
glare.
All external light sources shall be white.
OK
X
9. ii
Sign lighting (external) should be shielded so that it
Issue: needs to be noted on drawing
illuminates only face of the sign and does not shine beyond
the edge of the sign.
X
9. iii
Channel letters with translucent faces must have no light
None proposed
spilling outward from the top, bottom, sides or back.
Faces and returns of channel letters shall be opaque when
None proposed
back -lit (halo -lit).
X
9. iv
Cabinet signs shall have a non - illuminated background, or
None proposed
an opaque (zero light transmission) background.
Cabinet signs shall be constructed such that no light spills
N/A
outward from the top, bottom, sides or back.
X
5.g
All illumination shall be non - blinking.
None proposed
X
5.h
An exposed light source that forms the body of a sign,
None proposed
(such as exposed neon signs), shall not be used in the
Entrance Corridors.
ARB ACTIONS
X
If LED lighting is proposed the sign drawing must state
Issue — note missing
The level of illumination provided by the LED lights will
REF
CHECKLIST ITEM
NOTES
not exceed the illumination produced by a single stroke of
30 milliamp (ma) neon.
X
Red acrylic 42283 has been determined to be an
No red proposed
inappropriate color for signs.
Pantone color match for 2283 is 485C.
Red 42793 has been approved as an acceptable substitute.
Pantone color match for 2793 is 187C.
X
ARB
Visual clutter resulting from adjacency, for example at the
No graphic proposed
Action
Hardee's locations, is a reasonable basis for not allowing
Memo:
illumination of the graphic.
5/7/12
STONEFIELD TOWN CENTER SIGN CRITERIA —This table outlines the approved design criteria for the north elevations of B2 and 133; the south elevations of A3, A4, C1 -2 and C1 -3; the east elevations of A3 (adjacent to the EC) and C1 -2; and the
west elevations of A4 and C1 -3 in the Stonefield Town Center.
ARB201400118, Rocksalt Sign
SIGN TYPE
Facade Signs ( *numbers correspond to
Projecting Signs
Canopy Signs
Awning Signs
Blade Signs
illumination details)
Panel with push- through
1. Channel letters
letters /graphics
2. Reverse channel letters
3. Panel with push- through
letters /graphics
Individual letters —external illumination
SIGN LOCATION
As noted on elevations. Minimum 8"
As noted on elevations
On any canopy
On valance of type 1 awnings only
In close proximity to storefront entry
clearance to architectural features; 10"
doors; aligned with architectural
clearance to top /bottom of mounting
features of storefront and fagade.
area. Panel signs only allowed on
May be outside area designated on
Building Al, AS and 131 facades that do
elevation drawings.
not have frontage on the Entrance
Corridors. OK
SIZE LIMITATIONS
Letter height max 30 ". Signs must be in
Signs must be in proportion with other
Letter height max 10 ". Logo and
Located on valance only
3' x 1'6"
proportion with other signs and the
signs and the overall building.
graphic signs max 10 ". Signs must be
overall building. OK
in proportion with canopy face, other
signs, and the overall building.
PROJECTION LIMITATIONS
N/A
36" Max projection from face of wall
N/A
N/A
9' minimum clearance from grade.
9' -0" min clearance from grade level
LETTER COLOR
Black, White, Warm Grays (Pantone
Black, White, Warm Grays (Pantone
Black, White, Warm Gray.
Unlimited
Black, White, Warm Gray
Warm Gray 1 -11)
Warm Gray 1 -11)
Match /harmonize with canopy
PMS for proposed bronze not indicated
color /material
TRIM CAP /RETURN COLOR
Trim cap color to match return color.
N/A
N/A
N/A
N/A
Return colors are Black, White, Warm
Grays. Individual formed letters
BACKGROUND /PANEL /BODY
Black, White, Warm Grays (Pantone
Black, White, Warm Grays (Pantone
N/A
Awning colors: Sunbrella Black 08,
Unlimited
COLOR
Warm Gray 1 -11)
Warm Gray 1 -11)
Natural 04, Charcoal Gray 44, Navy
Blue 26, Alpine Green 55, Panorama
Taupe 48
MOUNTING DETAILS
Mounted to exterior wall
Mounted to exterior wall
Mounted to canopy face. Sign
Printed on awning valance
-
OK
elements cannot extend above or
below canopy edges.
GRAPHICS
Colors and illumination are subject to
Colors and illumination are subject to
Unlimited
Unlimited
Colors and illumination are subject to
review None proposed
review
review.
ILLUMINATION DETAILS
*Numbers correspond to sign type
Halo- Illuminated push- through
Non - illuminated
Non - illuminated
Non - illuminated
1. External Illumination details needed
2. Halo Illumination
3. Halo- Illuminated push- through
LETTER TYPE /FONT
Unlimited
Unlimited
Unlimited
Unlimited
-
MATERIALS
Unlimited
Unlimited
Unlimited
Fabric
-
NOTES: 1. Logo /graphics colors are subject to EC review. 2. Illumination of logos /graphics is subject to EC review. 3. Sign size is subject to EC review for appropriate scale and proportion. 4. Sign colors are subject to review for compatibility.
Completeness Check for Signs
Project # /Name: _201400118, Rocksalt Sign
Date Received at County: _08/28/2014
Date Received in Design Planning: _08/29/2014
Date of Checklist Check: _08/29/2014 Assigned to /Date: _08/29/2014
FEES
3. ARB Review —Will the permanent sign(s) be constructed in an Entrance Corridor?
(Seethe Entrance Corridor map in the Sign Permit Application packet for a list of Entrance Corridors.)
❑ Yes (This sign will be constructed in an Entrance Corridor and it does not meet the conditions of a $120.00
Comprehensive Sign Review. See ARB requirements next pages.)
❑ Yes (This sign will be constructed in an Entrance Corridor and it does meet the conditions of a Waive Fee
Comprehensive Sign Review. See ARB requirements next pages) OK
❑ No (This sign will not be constructed in an Entrance Corridor) $ 0.00
FEE TOTAL (Please add all the amounts checked in sections I — 3): $
FREESTANDING SIGNS N/A
A. Submittal Requirements
❑ Site plan or latest approved plat showing, to scale, the proposed location of the sign(s) with dimensions.
❑ Distance from the sign to the property lines and/or edge of the VDOT right -of -way.
❑ If the sign will be located in an easement, a letter of approval from the easement holder will be required.
❑ A to -scale color illustration of the proposed sign showing
❑ Dimensions of the sign, including overall height from the ground; cabinet size, length, width and depth; base
size, etc. (Be sure to also include these dimensions on the diagrams provided in the Sign Permit Application packet.)
❑ Proposed lettering and/or graphics in their proposed location.
❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor, also provide a color
illustration of the front and side elevations of the sign showing:
• If internally illuminated, indicate which areas of the sign are opaque and which are illuminated. Internally
illuminated cabinet signs must have opaque backgrounds. (Opaque materials don't allow light to pass through.
When lit only from behind, the color of an opaque material cannot be detected nor can objects be seen through it.)
• Identification of proposed materials and colors. Include standard color id numbers (Pantone, Benjamin Moore,
Acrylic, etc.) for all materials, text, graphics, base, faces, trim caps, returns, etc.
• Provide accurate physical samples of all colors proposed, preferably in the material proposed. (Paint chips that
accurately reflect the proposed colors are acceptable.)
• Provide a site plan showing proposed landscaping around the sign, including botanical names and planting sizes.
• Additional submittal materials may be required if review by the Architectural Review Board is necessary. (The
applicant will be notified if this requirement applies.)
WALL SIGNS
❑ A drawing, to scale, showing dimensions of the sign (length, height, depth). OK
❑ Elevation drawing(s) or modified photograph of the entire building, to scale and in color, showing
❑ The sign location on the building, sign height above grade, and the length of building frontage. (Be sure to also
include these dimensions on the diagrams provided in Appendix B) OK
❑ Sign lettering and /or graphics in their proposed location. OK
❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor also provide a color
illustration of the front and side elevations of the sign showing:
• Indication of sign type (channel letters, cabinet, panel, etc.). OK
• Indicate on the drawings the proposed materials and colors. Include standard color identification numbers
(Pantone, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, faces, trim caps, etc. For channel letter
signs, indicate on the drawing that the raceway color shall match the color of the wall to which the raceway is
attached. OK
• Provide accurate physical samples of all colors proposed in the sign, preferably in the material proposed. (Paint
chips that accurately reflect the proposed colors are acceptable.) OK
• Location of proposed light fixtures and manufacturer cut sheets describing illumination type, intensity, style,
shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17. Not
Addressed
o For internally illuminated signs, indicate which areas of the sign are opaque and which are illuminated. (Opaque
materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be
detected nor can objects be seen through it.) N/A
ILLUMINATION REQUIREMENTS
❑ The location of proposed light fixtures identified on a plan and/or elevation
❑ Manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must
meet ordinance requirements as outlined in Section 4.17 of the Zoning Ordinance.
NOTES: