Loading...
HomeMy WebLinkAboutARB201400118 Checklist 2014-08-29RESUBMITTAL REVIEW CHECKLIST PROJECT #/NAME: ARB 201400118, Rocksalt Sign 09/25/2014 ARB COMMENT (original review) 09/16/2014 Review 09/25/2014 Review X 1. Sign Drawing Label: OK - done a. Revise sign drawing label for "New Proposed East Elevation" to read "New Proposed Northeast (front) Elevation ". b. Revise the sign drawing label for "New Proposed North Elevation" to read "New Proposed Northwest (side) Elevation ". X 2. Sign Colors: OK — done a. Revise the sign drawing to indicate the Pantone color number for the proposed Duranodic Bronze letter face. Approved CSC allow for Warm Gray 1 — 11. X 3. Sign Lighting: OK a. Revise the sign drawing to include: Drawing shows use of 19 watt (1,300 i. A note indicating the wall signs are lumens) bulbs to be externally illuminated, assuming they are. OK - done ii. A note indicating the manufacturer and model number of the light fixture. OK - done iii. The following note: "The light fixture is to be shielded and positioned so that it illuminates only the face of the sign." OK - done iv. The location of the proposed wall light fixtures. OK -done v. The following note if LED illumination is proposed: "The level of illumination provided by the LED lights will not exceed the illumination produced by a ARB COMMENT (original review) 09/16/2014 Review 09/25/2014 Review single stroke of 30 milliamp (ma) neon. Issues: LED does not come in 35 watts b. Revise the lighting cutsheet provided by indicating all of the options chosen including model number, fixture finish, light source (bulb type /wattage) and mounting type; black and bronze are considered appropriate colors. Issues: bulb type not provided. http: / /www. base ite. com /pdfs /catalogs /baselite- sign - lights - catalog. pdf RESUBMITTAL REVIEW CHECKLIST PROJECT #/NAME: ARB 201400118, Rocksalt Sign 09/16/2014 ARB COMMENT (original review) 09/16/2014 Review X 1. Sign Drawing Label: OK - done a. Revise sign drawing label for "New Proposed East Elevation" to read "New Proposed Northeast (front) Elevation ". b. Revise the sign drawing label for "New Proposed North Elevation" to read "New Proposed Northwest (side) Elevation ". X 2. Sign Colors: OK — done a. Revise the sign drawing to indicate the Pantone color number for the proposed Duranodic Bronze letter face. Approved CSC allow for Warm Gray 1 — 11. X 3. Sign Lighting: a. Revise the sign drawing to include: i. A note indicating the wall signs are to be externally illuminated, assuming they are. OK - done ii. A note indicating the manufacturer and model number of the light fixture. OK - done iii. The following note: "The light fixture is to be shielded and positioned so that it illuminates only the face of the sign." OK - done iv. The location of the proposed wall light fixtures. OK -done v. The following note if LED illumination is proposed: "The level of illumination provided by the LED lights will not exceed the illumination produced by a ARB COMMENT (original review) 09/16/2014 Review single stroke of 30 milliamp (ma) neon. Issues: LED does not come in 35 watts b. Revise the lighting cutsheet provided by indicating all of the options chosen including model number, fixture finish, light source (bulb type /wattage) and mounting type; black and bronze are considered appropriate colors. Issues: bulb type not provided. http: / /www. baselite.com /pdfs /catalogs /baselite- sign- lights- catalog. pdf SIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business ARB 201400118, Rocksalt Sign 09 -10 -2014 ARB 201400118, Rocksalt Sign REF CHECKLIST ITEM NOTES TYPE • 9.b For internally illuminated signs, channel lettering OK — individual (not internally illuminated) letters (mounted on a raceway or individual letters) is preferred to cabinet signs. • 5.b When channel letters cannot be adequately accommodated, N/A internally illuminated cabinet signs may be considered. • 6 Reader boards are discouraged. None proposed MATERIALS • 4.c Materials used in the sign should complement the building OK being served by the sign. COLOR • 4.e Color for raceway- mounted channel letters, the raceway N/A — direct -mount shall match the wall color. Sign colors must be harmonious with each other. Issue: PMS# for Duranodic bronze color not provided. CSC require it match PMS Warm Gray 1 -11 Sign colors must not clash with the site, when viewed in OK daylight and at night. Overly intense color, (such as dayglo or fluorescent None proposed colors), are prohibited. Use of three colors or less (black and white considered as OK-2 colors) Additional colors may be approved if they contribute to the sign balance /unity. SIZE, SCALE, PROPORTION, AND LOCATION • 4.b I Signs may not exceed the size, height and setback OK — per S. Wright REF CHECKLIST ITEM NOTES requirements as outlined in Section 4.15 of the Albemarle 2 signs - 14.1 sq ft and 3.1 sq ft = 17.2 sq ft proposed - County Zoning Ordinance (unless sign has a variance). 69 sq ft max allowed CLE2014 -72 • Appendix A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall OK A.A area is a good working proportioning system for placing a sign. • Appendix Color, form, surface pattern, shape, and disposition of OK A.A.4 elements and openings in an architectural design can affect our perception of scale and can impact the appearance of a sign on a building. • 9.d The wall sign's size must coordinate with the architectural OK — in approved location element's size. The sign should not over -crowd the architectural element, OK the wall, or the sign area. Buildings and building elements should not be used as OK billboards. • 9.a Wall signs must integrate with the building's architecture. OK — in approved location The sign placement should not obscure architectural OK features or details, (such as cornices, windows, columns, pilasters and paneling). • 9.d An appropriate height for channel letters in a 30" high sign N/A band is 18 ". This allows 6" of unoccupied space above and below the N/A letters. 4" of clear space above, below, and to the sides of a N/A channel letter sign is considered a minimum, with larger clearances required for larger sign bands. REF CHECKLIST ITEM NOTES Degree of visibility, the distance from the Entrance OK Corridor, and the architectural design of the building /area will determine sign size, placement, and proportions. • 4.d Lettering should be in proportion (font size and typeface OK style) to the sign and the building. Use of three typefaces or less. OK Additional typefaces may be approved if they contribute to N/A a balanced /legible /unified sign design. • 9. e. iv The width of the outline must be in proportion to the width OK of the letter. CSC do not allow for outlines; however impact sufficiently reduced by distance from EC and use of external illumination (versus internal). An outline width of 1/8" has been found to be an OK appropriate sign dimension. TRADEMARKS, CORPORATE LOGOS AND GRAPHICS • 4.f The ARB may require that the color and scale of standard None proposed templates for trademarks, service marks, corporate logos and graphics be modified. When used, trademarks, service marks, corporate logos N/A and /or graphics should be incorporated as an integral part of the overall sign. • 5.a External (or no) illumination is preferred for approved N/A graphics /logos; • 5.b internal illumination may be considered for approval on a N/A case -by -case basis. LIGHTING • 9.e.i External (or no) illumination is preferred for wall signs. Issues: • External lighting proposed — cutsheet provided — chosen options not indicated — fixture arm not provided. REF CHECKLIST ITEM NOTES • Location of fixtures on wall not provided. X S.f Any internal illumination is considered to contribute to None proposed visual clutter and will be limited. X 5.c Internal illumination design approval will be evaluated on N/A size, balance, complexity, and distance from the Entrance Corridor. X 9. e. iv The backgrounds of such cabinet signs must be made None proposed opaque (zero light transmission). X 5.e External illumination should be shielded and not create None proposed glare. All external light sources shall be white. OK X 9. ii Sign lighting (external) should be shielded so that it Issue: needs to be noted on drawing illuminates only face of the sign and does not shine beyond the edge of the sign. X 9. iii Channel letters with translucent faces must have no light None proposed spilling outward from the top, bottom, sides or back. Faces and returns of channel letters shall be opaque when None proposed back -lit (halo -lit). X 9. iv Cabinet signs shall have a non - illuminated background, or None proposed an opaque (zero light transmission) background. Cabinet signs shall be constructed such that no light spills N/A outward from the top, bottom, sides or back. X 5.g All illumination shall be non - blinking. None proposed X 5.h An exposed light source that forms the body of a sign, None proposed (such as exposed neon signs), shall not be used in the Entrance Corridors. ARB ACTIONS X If LED lighting is proposed the sign drawing must state Issue — note missing The level of illumination provided by the LED lights will REF CHECKLIST ITEM NOTES not exceed the illumination produced by a single stroke of 30 milliamp (ma) neon. X Red acrylic 42283 has been determined to be an No red proposed inappropriate color for signs. Pantone color match for 2283 is 485C. Red 42793 has been approved as an acceptable substitute. Pantone color match for 2793 is 187C. X ARB Visual clutter resulting from adjacency, for example at the No graphic proposed Action Hardee's locations, is a reasonable basis for not allowing Memo: illumination of the graphic. 5/7/12 STONEFIELD TOWN CENTER SIGN CRITERIA —This table outlines the approved design criteria for the north elevations of B2 and 133; the south elevations of A3, A4, C1 -2 and C1 -3; the east elevations of A3 (adjacent to the EC) and C1 -2; and the west elevations of A4 and C1 -3 in the Stonefield Town Center. ARB201400118, Rocksalt Sign SIGN TYPE Facade Signs ( *numbers correspond to Projecting Signs Canopy Signs Awning Signs Blade Signs illumination details) Panel with push- through 1. Channel letters letters /graphics 2. Reverse channel letters 3. Panel with push- through letters /graphics Individual letters —external illumination SIGN LOCATION As noted on elevations. Minimum 8" As noted on elevations On any canopy On valance of type 1 awnings only In close proximity to storefront entry clearance to architectural features; 10" doors; aligned with architectural clearance to top /bottom of mounting features of storefront and fagade. area. Panel signs only allowed on May be outside area designated on Building Al, AS and 131 facades that do elevation drawings. not have frontage on the Entrance Corridors. OK SIZE LIMITATIONS Letter height max 30 ". Signs must be in Signs must be in proportion with other Letter height max 10 ". Logo and Located on valance only 3' x 1'6" proportion with other signs and the signs and the overall building. graphic signs max 10 ". Signs must be overall building. OK in proportion with canopy face, other signs, and the overall building. PROJECTION LIMITATIONS N/A 36" Max projection from face of wall N/A N/A 9' minimum clearance from grade. 9' -0" min clearance from grade level LETTER COLOR Black, White, Warm Grays (Pantone Black, White, Warm Grays (Pantone Black, White, Warm Gray. Unlimited Black, White, Warm Gray Warm Gray 1 -11) Warm Gray 1 -11) Match /harmonize with canopy PMS for proposed bronze not indicated color /material TRIM CAP /RETURN COLOR Trim cap color to match return color. N/A N/A N/A N/A Return colors are Black, White, Warm Grays. Individual formed letters BACKGROUND /PANEL /BODY Black, White, Warm Grays (Pantone Black, White, Warm Grays (Pantone N/A Awning colors: Sunbrella Black 08, Unlimited COLOR Warm Gray 1 -11) Warm Gray 1 -11) Natural 04, Charcoal Gray 44, Navy Blue 26, Alpine Green 55, Panorama Taupe 48 MOUNTING DETAILS Mounted to exterior wall Mounted to exterior wall Mounted to canopy face. Sign Printed on awning valance - OK elements cannot extend above or below canopy edges. GRAPHICS Colors and illumination are subject to Colors and illumination are subject to Unlimited Unlimited Colors and illumination are subject to review None proposed review review. ILLUMINATION DETAILS *Numbers correspond to sign type Halo- Illuminated push- through Non - illuminated Non - illuminated Non - illuminated 1. External Illumination details needed 2. Halo Illumination 3. Halo- Illuminated push- through LETTER TYPE /FONT Unlimited Unlimited Unlimited Unlimited - MATERIALS Unlimited Unlimited Unlimited Fabric - NOTES: 1. Logo /graphics colors are subject to EC review. 2. Illumination of logos /graphics is subject to EC review. 3. Sign size is subject to EC review for appropriate scale and proportion. 4. Sign colors are subject to review for compatibility. Completeness Check for Signs Project # /Name: _201400118, Rocksalt Sign Date Received at County: _08/28/2014 Date Received in Design Planning: _08/29/2014 Date of Checklist Check: _08/29/2014 Assigned to /Date: _08/29/2014 FEES 3. ARB Review —Will the permanent sign(s) be constructed in an Entrance Corridor? (Seethe Entrance Corridor map in the Sign Permit Application packet for a list of Entrance Corridors.) ❑ Yes (This sign will be constructed in an Entrance Corridor and it does not meet the conditions of a $120.00 Comprehensive Sign Review. See ARB requirements next pages.) ❑ Yes (This sign will be constructed in an Entrance Corridor and it does meet the conditions of a Waive Fee Comprehensive Sign Review. See ARB requirements next pages) OK ❑ No (This sign will not be constructed in an Entrance Corridor) $ 0.00 FEE TOTAL (Please add all the amounts checked in sections I — 3): $ FREESTANDING SIGNS N/A A. Submittal Requirements ❑ Site plan or latest approved plat showing, to scale, the proposed location of the sign(s) with dimensions. ❑ Distance from the sign to the property lines and/or edge of the VDOT right -of -way. ❑ If the sign will be located in an easement, a letter of approval from the easement holder will be required. ❑ A to -scale color illustration of the proposed sign showing ❑ Dimensions of the sign, including overall height from the ground; cabinet size, length, width and depth; base size, etc. (Be sure to also include these dimensions on the diagrams provided in the Sign Permit Application packet.) ❑ Proposed lettering and/or graphics in their proposed location. ❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor, also provide a color illustration of the front and side elevations of the sign showing: • If internally illuminated, indicate which areas of the sign are opaque and which are illuminated. Internally illuminated cabinet signs must have opaque backgrounds. (Opaque materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be detected nor can objects be seen through it.) • Identification of proposed materials and colors. Include standard color id numbers (Pantone, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, base, faces, trim caps, returns, etc. • Provide accurate physical samples of all colors proposed, preferably in the material proposed. (Paint chips that accurately reflect the proposed colors are acceptable.) • Provide a site plan showing proposed landscaping around the sign, including botanical names and planting sizes. • Additional submittal materials may be required if review by the Architectural Review Board is necessary. (The applicant will be notified if this requirement applies.) WALL SIGNS ❑ A drawing, to scale, showing dimensions of the sign (length, height, depth). OK ❑ Elevation drawing(s) or modified photograph of the entire building, to scale and in color, showing ❑ The sign location on the building, sign height above grade, and the length of building frontage. (Be sure to also include these dimensions on the diagrams provided in Appendix B) OK ❑ Sign lettering and /or graphics in their proposed location. OK ❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor also provide a color illustration of the front and side elevations of the sign showing: • Indication of sign type (channel letters, cabinet, panel, etc.). OK • Indicate on the drawings the proposed materials and colors. Include standard color identification numbers (Pantone, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, faces, trim caps, etc. For channel letter signs, indicate on the drawing that the raceway color shall match the color of the wall to which the raceway is attached. OK • Provide accurate physical samples of all colors proposed in the sign, preferably in the material proposed. (Paint chips that accurately reflect the proposed colors are acceptable.) OK • Location of proposed light fixtures and manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17. Not Addressed o For internally illuminated signs, indicate which areas of the sign are opaque and which are illuminated. (Opaque materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be detected nor can objects be seen through it.) N/A ILLUMINATION REQUIREMENTS ❑ The location of proposed light fixtures identified on a plan and/or elevation ❑ Manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17 of the Zoning Ordinance. NOTES: