Loading...
HomeMy WebLinkAboutSDP201400021 Correspondence 2014-02-25 *NO' 0000:000000e ■ ur less Hand-delivered May 5, 2014 TO: Brent Nelson, Planner County of Albemarle Department of Community Development 401 Mchltire Road - North Wing Charlottesville, Virginia 22902 RE: SDP-2014-00021 - Cash Corner- Howard Property Verizon Wireless Tier II PWSF Dear Brent: For your review, please find four (4) full-sized (1 1" x 17") copies of the revised site plan /construction drawings and supporting information for Verizon Wireless' proposed Personal Wireless Service Facility attached with this letter. These plans have been revised to address the comments in your review letter, dated April 9, 2014. Please do not hesitate to contact me at your earliest convenience if you should have any questions regarding this re-submittal. Sincerely, r . of Step en Waller, AICP Planner/ Site Development Consultant GDN Sites Consultants to Verizon Wireless stephen.waller @gdnsites.com Attachments: SRC Responses & Revisions Memo Revised Site Plan / Construction Drawings TIERPLAN REVISION MEMORAUM To: Brent Nelson, Division of Planning Troy Austin, P.E., Virginia Department of Transportation Max Greene, Division of Engineering From: Stephen Waller, AICP (434-825-0617) Date: May 5, 2014 RE: SDP-2014-00021 - Cash Corner- Howard Property/Verizon Wireless Tier II PWSF Verizon Wireless will address the Department of Community Development's site review comments, dated April 9, 2014, and questions resulting from the site visit and balloon test below: Albemarle County Division of Planning Reviewer: Brent Nelson, Planner, Department of Community Development Planning Services 1. [Section 5.1.4(c)(4) & (5)J - Sheet C-4B Enlarged Grading Plan shows proposed grading and the installation of.fencing within the drip line of an existing tree designated to remain. A tree conservation plan prepared by a certified arborist verifying that the tree could survive this impact is required for a building permit to be issued. Prior to the issuance of a building permit, Verizon Wireless will provide a tree conservation plan prepared by a certified arborist. Any necessary requirements and recommendations from this plan will incorporated in the final site plan and construction drawings. 2. [Section 5.1.40(f)] - On Sheet C-2 Tree Inventory, the existing tree directly east of the fhcility does not have a tree inventory number. Revise the drawing to indicate the tree inventory number. Sheet C-2 has been revised with a label identifying this tree as Tree#60 from the inventory. 3. [Section 5.1.4(c)(7)J - This is not a condition of approval.for the proposal under review, just a reminder. This requirement is acknowledged as a requirement for future operations of this facility. 4. [Section 5.1.40(-I)(e)J—Sheet C-IA Area Map shows the parcels within a 2000'radius of the site: however, the topo within that 2.000 radius is not shown. Revise the drawing to include the topo, in contour intervals not exceeding ten (10)feet. Sheet C-IA has been revised to show the topographic data as required. 5. [Section 5.1.40(d)(7)J On Sheet C-5 Civil Details, add a note to the sheet indicating that the.fence will be painted Java Brown to match the monopole. Sheet C-5 has been revised to indicate that the wood fence shall be stained to match the Java Brown paint on the monopole, as the standard paint would not hold to treated wood . 1\000.0000000000.000., s Wiregrwiredess TIER PLAN REVISION MEMORAII 15UM 6. Miscellaneous a. On Sheet G-1 Cover Sheet, the zoning is mislabeled as A-1 (should be RA), the parcel is mislabeled as TMP 50-42A (should be TMP 50-41A) and the acreage is listed as 96 (should be 61.86 acres). Revise the drawing to correct. The site zoning abbreviation and tax map number have both been corrected in the project summary on Sheet G-1. b. Sheet C-5 Civil Details show a chain link fence detail hut chain link.fencing is not proposed on the site plan. Remove the chain link fence detail if it is not to he used. Sheet C-5 has been revised to correctly show the details for a wood screening fence. Virginia Department of Transportation Reviewer: Troy Austin, P.E, Area Land Use Engineer, Culpeper District. 1. The proposed entrance to Route 615 will is acceptable. The entrance la'ill need to he improved to PE-1 standards. Prior to this work occurring, a Land Use Permit will need to be obtained from this office. Verizon Wireless will submit a VDOT Land Use Permit application at the time when the building permit is being submitted for this project. Sheet C-4G has been added showing the detail for standard private entrances (VDOT PE-1). 2. VDOT has no objection to this project provided that the entrance is improved as indicated above. Sheet C-4G has been added and the plans have been revised to show the required entrance design. Albemarle County Division of Engineering Reviewer: Max Greene. 1. Plan appears to show land disturbance in excess of 10,000 square feet and will require an Erosion and Sediment Control plan to be submitted and approved prior to.final site plan approval. An Erosion and Sediment Control (ESC) plan has been prepared as required. The E&SC Plan consists of the plans and details provided on Sheets C-4A through C-4G and an E&SC Narrative which describes the E&SC measures that will be provided, as detailed in the site plan and construction documents. Two (2) copies the site plan and construction package containing the E&SC plan and narrative are being submitted separately along with the required application and fees. Please contact me at your earliest convenience if you should have any questions. ‘440•#.#4.1°#..****6°°"r fxr virenz2pwitik3ss