Loading...
HomeMy WebLinkAboutSUB202200178 Review Comments Preliminary Plat 2022-12-12Albemarle County Planning Services (Planner) Andy Reitelbach, mreitelbach@albemarle.org SUB2022-00178 Montgomery Ridge Phase 4 Preliminary Plat 1. [14-409(B)] Extension ofstreets. The public streets in this development must be extended and constructed to the abutting property lines for future development on adjoining lands. At least one of the public streets in this development must be extended to the property line of adjacent TMP 46-26, including reservation of any necessary temporary construction easements of sufficient area to allow future completion when developed. 2. [18-30.2.61 Cluster development, bonus factors. The Planning Commission must consider this application, as the PC must determine that a development located in the Airport Impact Area overlay district and using the cluster development or bonus factor provisions or regulations will reduce or be equivalent to hazard and/or noise impacts anticipated under standard -level conventional development of the underlying zoning district. 3. [14-422] Sidewaiksand p/antingstdps. The request to vary the requirements for providing sidewalks and planting strips on both sides of a public street must be approved by the Planning Commission prior to approval of a preliminary subdivision plat. Because these requests were submitted as a separate application (SUB2022-00190), see the separate comment section below that provides comments specifically on the sidewalk and planting strip waiver requests. 4. [14-303] The final subdivision plat must demonstrate compliance with all requirements of Section 14-303 of the Subdivision Ordinance and include all of the items listed in that section. 5. [34-302(A)4; 14-302(A)6] Identify the private easement that currently gives access to the subject parcel (TMP 46- 24) along the Powell Ridge road, including its deed book and page number and the width of the right-of-way. It appears that private grading easements will be required on adjacent parcels, such as TMPs 46D-40, 46D-39, and 46D-B1. These easements will need to be shown on the final plat or on a separate easement plat, with the respective property owners' signatures. 6. [34-302(A)5] Proposed public easements, such as for stormwater management, will need to be shown on the final subdivision plat. These easements may require deeds. 7. [34-302(A)8] The area of each proposed new lot needs to be provided. 8. [34-302(A)14] The land of parcel 46D-A2 needs to be included in the calculations of property to be dedicated to the County, since it is proposed to be a part of this subdivision. 9. [34-302(A)8] The name and a mailing address for the property owner of TMP 46D-A2 needs to be included on this plat, as this property is proposed to be a part of this subdivision. 10. [34-302(B)1] The date of the last revision of the plat needs to be included on all future submittals of the plat. 11. [34-302(B)5] The note on the cover sheet and the labelling of the preserved steep slope areas need to be revised. These areas are not being re-classified as managed steep slopes. Only the Board of Supervisors can re-classify steep slopes through a rezoning. The preserved slope areas are being "treated" as managed steep slopes if they have a slope of less than 25%. 12. [34-302(B)8] There is a label on Lot 14 indicating a 25-ft. max. setback. Remove this label, as there is no maximum setback requirement for the R-1 zoning district. 13. [14-311] With the final subdivision plat, the required infrastructure plans, computations, and documents will need to be submitted. 14. [14-316] Approval of all entrances onto public streets will be required prior to approval of the final subdivision plat. 15. [34-303(N)] The following statement will need to be on the final plat: "Unless specifically denoted as public, the streets and other required improvements in this subdivision are private in nature and will not be maintained by either the Virginia Department of Transportation or any other public agency. The maintenance thereof is the mutual obligation of the affected lot owners. Failure to maintain the improvements in substantially the same condition as originally approved by the County may constitute a violation of County ordinance(s)." 16. [14-400; 18-13.3)] The plat needs to demonstrate that all buildable lots (not open space, special lots, ROW, etc.) are a minimum of 20,000 square feet and have a minimum of 80 feet of road frontage (allowing for reduced frontage for those lots located on cul-de-sacs). 17. [14-400;18-13.3)] Lots 2 and 6 do not appear to be meeting the front setback requirement. The front setback must be measured at 5-ft. from the spot where the lots measure 80 feet across on the front side of the parcel. 18. [38-2.4.3(a)] A conservation plan that is compliant with Section 32.7.9 must be submitted as a part of the request for a bonus factor for environmental standards. 19. [14-431] Easements for stormwater management facilities will be required for this development These easements will need to be approved and recorded prior to or at the same time as the final subdivision plat. 20. [General Comment] A road plan will be required for this development. 21. [General Comment] Please note that additional comments may be provided with the submission and review of the final subdivision plat for this project. SUB2022-00190 Montgomery Ridge Phase 4 - Planting Strip and Sidewalk Variation/Waiver Requests 1. In reviewing these requests, it appears that most of the sidewalk and planting strip areas that are proposed to be varied/waived are located on the property (TMP 46D-A2) owned by the Montgomery Ridge Owners Association, with only a portion also located on TMP 46-24, owned by Heahmor LLC. Because of this situation, an authorized representative of the Montgomery Ridge Owners Association must also sign the application for the requested variations/waivers. Heahmor LLC cannot sign a variation/waiver request on behalf of the other property owner. 2. The applicant's justification for the variation/waiver requests mentions that the width of the existing parcel where the new street is proposed is 40 feet. However, the combined with of the proposed improvements listed is only 39 feet. What is the other one -foot segment proposed to be? Comments from Other Reviewing Departments and Agencies Albemarle County Engineering Services (Engineer) Frank Pohl, fpohl@albemarle.org - Requested changes; see the attached comment memo. Albemarle County Information Services (E911) Andy Slack, aslack@albemarle.org - No objections at this time. Albemarle County Building Inspections Betty Slough, bslough@albemarle.ore - No objections at this time. Albemarle County Fire -Rescue (ACFR) Howard Lagomarsino, hlagomarsino@albemarle.ore - No objections at this time. Albemarle County Service Authority (ACSA) Richard Nelson, rnelson@serviceauthority.org - Requested changes; see the comments below: Submit water/sewer plans and water/sewer data sheets to ACSA. Utility plan approval will be required prior to final plat approval. Offsite sanitary sewer easement will be required for utility plan approval. Show existing sewer behind existing Montgomery Ridge. Refer to updated ACSA specs for sanitary sewer easement widths based on depth. Explore other sewer alignment for the sewer segments at lot 13. Virginia Department of Health (VDH) - Blue Ridge Health District Alan Mazurowski, alan.mazurowski(a)vdh.vireinia.eov - No objections at this time; see the attached comment memo. Virginia Department of Transportation (VDOT) John Wilson, lohn.c.wilson@vdot.virginia.gov - Requested changes; see the attached memo. Rivanna Water and Sewer Authority (RWSA) Dyon Vega, dvega@rivanna.org - No objections at this time. Attachments Engineering Comment Memo, dated December 8, 2022 VDH Comment Memo, dated November 27, 2022 VDOT Comment Memo, dated November 14, 2022 $ County of Albemarle m COMMUNITY DEVELOPMENT DEPARTMENT Memorandum To: Andy Reitelbach, Senior Planner II From: Frank Pohl, PE., County Engineer Date: December 8, 2022 Subject: Montgomery Ridge Phase IV (SUB202200178) Preliminary Plat 401 McIntire Road, North Wing Charlottesville, VA 22902-4579 Telephone: 434-296-5832 WWW.ALBEMARLE.ORG The referenced preliminary plat has been reviewed by Engineering. Please refer to comments provided below. 1. [14-302.A.5] —Easements. a. Call -out the proposed public easement around the SWM facility and show temporary offsite grading easements. These can be provided with the WPO submittal. b. Provide the existing, offsite sewer easement DB/PG information and show the easement on the final plat. A new offsite sewer easement may be required. 2. It doesn't appear the proposed SWM facility will provide adequate volume control for the drainage area. This can be addressed with the WPO submittal. 3. Access to the SWM facility appears to be down a 2:1 slope. Access will need to meet requirements of VA DEQ Stormwater Design Specification Number 15, Section 6.8. This can be addressed with the WPO submittal. Blue Ridge Health District VIRGINIA DPARtMEN1 OF HEALTH Andy Reitelbach, Senior Planner II Albemarle County Community Development 401 McIntire Road Charlottesville, VA 22902 RE: Montgomery Ridge, Phase 4 Preliminary Subdivision Plat SUB2022-178 Tax Map: 46-24 Mr. Reitelbach: ChabMsvMa/AWernade NMNh Depadment 1 138 Rose 41 Dive Chanollesvile, VA 22903 Ofte 434-972-6200 1 fax 434-972-4310 November 27, 2022 As requested, I have reviewed the subject plat, dated 9/6/22, for the proposed development, referenced above. Since both water and sewer will be provided by public systems, and there does not appear to be any existing onsite well or septic systems that will be impacted, I have no objection to the proposed development and recommend approval. If there are any questions or concerns, please give me a call, 434-972-4306. Sincerely, Alan Mazurowski Environmental Health Supervisor Blue Ridge Health District alan.mazurowski ,vdh.vir i� og_v Stephen C. Brich, P.E. Commissioner (Z) COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1401 East Broad Street Richmond, Virginia 23219 November 14, 2022 Andy Reitelbach County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Re: SUB-2021-00178 — Montgomery Ridge, Phase 4 - Preliminary Plat Dear Mr. Reitelbach: (804) 786-2701 Fax: (804) 786,2940 The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced Proffit Road Townhomes North Final Plat, as submitted by Collins Engineering, dated September 06, 2022 and find the following: 1. Minimum centerline road radii is 200' for acceptance into the State system. Please redesign the proposed road alignment to meet or exceed the minimum requirements per RDM Appendix B(1). If a 200ft centerline radius is not achievable, submit a design exception for VDOT's review, the exception should be included with the road plan submission. 2. Please review the proposed contours for accuracy. See lot 8 grading. 3. Approved road plans meeting SSAR, and in compliance with the VDOT Road Design Manual are required prior to plat approval. 4. Please show the mail boxes & cluster box units per RDM Appendix B(1)-56 . 5. Please include a note stating that VDOT will only maintain within drainage easements to the extent necessary to protect the roadway from flooding or damage. 6. Note that the final plan must show conformance with the VDOT Road Design Manual Appendices B(1) and F, as well as any other applicable standards, regulations or other requirements. 7. Please provide a comment response letter with each submission after the initial. A VDOT Land Use Permit will be required prior to any work within the right of way. The owner/developer must contact the Charlottesville Residency land Use Section at (434) 422-9399 for information pertaining to this process. If you have further questions please contact Max Greene at (434) 422-9894. VirginiaDOT.org WE KEEP VIRGINIA MOVING Sincerely, John C. Wilson, P.E. Assistant Resident Engineer Area Land Use Charlottesville Residency