HomeMy WebLinkAboutARB201400083 Plan - Other (not approved) 2014-06-26I A 28" H &R Block
. - Channel Letters on a Raceway
Internally Illuminated LED
.. ..• 5.44 +12.30 =17.74
. - Top of sign to grade = 16' -1"
N
Bottom of sign to grade = 13' -9"
H &R BLOCK
Client: H &R BLOCK
• 06/19/2014
Permit Rendering
NK
This rendering is the property of Anchor
Sign. Inc. It is for the exclusive use of
Anchor sign. Inc. and the party which
requested the rendering. It is an .
unpublished original drawing not to be
distributed, reproduced exhibited
without the consent oFAncho hor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Site #: 11 14711
Address: 249 Connor Dr.
•
Charlottesville, VA22911
SIGN A 28" H &R Block
. • Channel Letters on a Raceway
• Internally Illuminated LED
5.44 + 12.30 = 17.74
. - Top of sign to grade = 16' -1"
Bottom of sign to grade = 13' -9"
Electrical Detail:
Sylvania 71071 White 6500K LEDs
(2) 60w Transformer @ 0.61 amp ea
Total Amps: 1.22
(1) 20 amp 120V Circuit Req. @LISTED
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
1) Grounded and bonded per NEC 600.7 /NEC 250
2) Existing branch circuit in compliance with
NEC 600.5, not to exceed 20 amps
3) Sign is to be UL listed per NEC 600.3
4) UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer`
`For multiple signs, a disconnect is permitted but
not required for each section
00 `v
N
12'- 101/2" [154
28" , 8" , 9'- 101/2" [1181
HR -IL 28 RW Sign Layout Detail
Scale: 1/2" = V -0"
1. Existing Facade: EIFS over Plywood over metal studs
2. 0.040" Aluminum letter returns painted to match PMS 430c Gray
and block logo returns to match PMS 376c
3. 0.125" x 1" trim cap Black and block logo to match PMS 376c
4. 3mm Signabond Lite composite backs
(interior of sign can painted ultra white for maximum illumination)
5. Sylvania 71071 White 6500K LEDs
6. 3/16" White #2447 Acrylic. Block logo with 3/16 White Acrylic and first surface
applied 3M #3630 -106 Brilliant Green vinyl.
7. Waterproof disconnect switch per NEC 600 -6
8. Primary electrical feed
9. Transformers
10. 0.080" Aluminum raceway painted to match SW 6120 Believable Bluff
11. 15" x 2" x 0.1875" Aluminum mounting tabs welded to raceway
- Maximum 6" from each end and every 48" o.c.
12. #12 x 1" TEC screws with 11/4" fender washers
13. 3/8" Thru Bolts w/ 1 5/8" x 1 5/8" 12 gauge Uni -Strut backer
F" d 119"
or lever cans tc/ per letter
Section @ LED Channel Ltr/ Raceway
Front -Lit Scale: N.T.S.
H &R BLOCK
Client: H &R BLOCK
• 06/19/2014
Permit Rendering
NK
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the pa ty which
requested the rendering. It is an •
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.. [I
Please contact your account manager
with questions regarding this statement,
Site #: HR -44755
Address: 249 Connor Dr.
Charlottesville, VA 22911
H &R BLOCK
SIGN A 28" H &R Block
. - Channel Letters on a Raceway
Internally Illuminated LED
• .. ..• 5.44 +12.30 =17.74
. • Top of sign to grade = 16' -1"
Bottom of sign to grade = 13' -9"
Charlottesville, VA
H &R BLOCK
Client: H &R BLOCK
• 06/1912014
Permit Rendering
NK
This rendering is the pro{
Sign. Inc. It is for the er
Anchor Sign. Inc. and If
requested the render
unpublished original dray
distributed. reproduced
without the consent of An
Please contact your acc
with questions regarding
Site #: HR -44755
Address: 249 Connor Dr.
•
Charlottesville, VA 22911
erty of Anchor
elusive use of
e party which
ng. It is an f- ft , .
ring not to be
or exhibited
Thor Sign, Inc.
cunt manager
his statement.