HomeMy WebLinkAboutWPO202000030 Certified Engineer's Report 2022-10-25® ROUDABUSH, GALE & ASSOCIATES, INC. E..E,.EEAA E,,,.. ...u,o P..,,.EE, E 2415 Ivy Rd Commercial Redevelopment — Pipe Inspection Summary Date: October 25, 2022 Summary: Roudabush Pipe Inspection Services conducted a video inspection on 10/25/22 of the storm water pipes at 2415 Ivy Rd . This inspection was at the request of Charlotte Harper and Hunter E. Craig Company. The purpose of this inspection was to verify proper installation and function of the installed storm pipes to VDOT standards. The facility was inspected with a Pearpoint P350 wheeled crawler camera with a pan/tilt/zoom Camera. Wincan pipe inspection software was used to document the inspections and produce an inspection report of the SWM facility. The inspection standards used were NASSCO PACP and VDOT VTM 123. Findings: Please find a summary of inspections on attachment A. Please contact kraineno.roudabush. com for any questions or a link to the inspection videos. Respectfully, Kent C Raine NASSCO Cart # U-0920- 703010383 Roudabush, Gale, and Associates, INC Pipe Inspection Services Attachment A: Pipe Inspection Report 6PROUDABUSH, GALE & ASSOC., Inc. A PROFESSIONAL CORPORATION Serving Virginia Since 1956 2415 Ivy rd Commerical Re -Development Pipe Inspection Summary ROUDABUSH,GALE AND ASSOCIATES 999 SECOND ST SE CHARLOTTESVILLE,VA 22902 434 977 0205 Inspector: Kent Raine NASSCO # U-0920-703010383 Date: 10-25-22 Testing methods : VTM 123, NASSCO Test Section # Storm Culvert Structure DIRECTION STREET Length Inspected Date comments Recommended Repair Size (in) Material Total # Inspections Start End 1 STORM 1A Ex srRM DOWN PARKING LOT 132.6 25-Oct-22 OK N/A 24 HDPE 1 2 STORM 1B 1A DOWN PARKING LOT 72.1 25-Oct-22 OK N/A 24 HDPE 1 3 STORM 1B 2 UP PARKING LOT 205.3 25-Oct-22 OK N/A 24 HDPE 1 4 STORM 6 2 DOWN PARKING LOT 93.2 25-Oct-22 OK N/A 24 HDPE 1 5 STORM 8 6 DOWN PARKING LOT 130.3 25-Oct-22 OK N/A 24 HDPE 1 6 STORM 8 10 UP PARKING LOT 153.7 25-Oct-22 OK N/A 24 HDPE 1 7 STORM 8 12 UP PARKING LOT 28 25-Oct-22 OK N/A 24 HDPE 1 8 STORM 14 OUTFALL DOWN PARKING LOT 78 25-Oct-22 DEPOSITS SETTLED- OK N/A 15 HDPE 1 9 STORM OUTFALL 14 UP PARKING LOT 15.7 25-Oct-22 REVERSE INSPECTION -OK N/A 15 HDPE 1 10 STORM 16 14 DOWN PARKING LOT 86.1 25-Oct-22 OK N/A 15 HDPE 1 11 STORM 1B 22 UP PARKING LOT 47.9 25-Oct-22 DEPOSITS SETTLED- OK N/A 15 HDPE 1 12 STORM OUTFALL 24 UP PARKING LOT 120 25-Oct-22 OK N/A 1 15 HDPE 1 13 STORM 26 24 DOWN PARKING LOT 1 3.8 1 25-Oct-22 OK N/A 1 15 1 HDPE 1 1 14 STORM 26 28 UP PARKING LOT 1 56.1 1 25-Oct-221 DEPOSITS SETTLED- OK N/A 1 15 1 HDPE I 1 TOTAL: I 1222A Deformations — Deformations are considered to be significant defects and according to ASTM are coded as failing when beyond 5% distortion. However, several factors are considered when giving our opinion of approval or rejection. Degree of deformation, materials used (rigid or flexible) and location of the pipe are all taken into account when determining functionality. These factors are subjectively considered when recommending repairs.