HomeMy WebLinkAboutSUB202100161 Review Comments Road Plan and Comps. 2022-12-26�q off pig 401 McIntire Road, North Wing Charlottesville, VA 22902-4579 County of Albemarle Telephone:434-296-5832 COMMUNITY DEVELOPMENT DEPARTMENT WWW.ALBEMARLE.ORG ��BGIN�Q' Road Plan Review Project title: Dunlora Farm Road and Drainage Plan Project file number: SUB202100161 Plan preparer: Chris Mulligan, PE — Roudabush, Gale & Assoc., Inc. 999 Second Street, SE, Suite 201 Charlottesville, VA 22902 cmulligankroudabush.com 440 Premier Circle, Suite 200, Charlottesville, VA 22901 Owner /Applicant: E. L. Phillips and Ann P. Phillips Liv. Trust, etal C/O Caroline Molina -Ray 6704 Menchaca Road, Unit 33, Austin TX, 78745 Applicant: Southern Development Homes, 142 South Pantops Dr. Charlottesville, VA 22911 charlesa(a),southem-development.com Date Received: 22 Sep 2021 (Rev. 1) 15 Mar 2022 [ Laserffche Notification, March 15, 2022 3:53 PM ]; 10/28/22, plan located /distributed [ review error, J. Anderson] Date of comments: 19 Nov 2021 (Rev. 1) 26 Dec 2021 Plan Reviewer: John Anderson Engineering has reviewed the ROAD Plan and offers the following: Sheet 1 1. Revise plan title to include reference to SUB202100161. (Rev. 1) Addressed. 2. Recommend revise plan title to include reference to Phase 1. (Rev. 1) Addressed. 3. Include title sheet note reference to associated plan: WP0202100063. (Rev. 1) Addressed. 4. Recommend title sheet note reference to Steep Slopes Exhibit approved 3/23/21, associated with preliminary subdivision plat, SUB2020-00223. (Rev. 1) Addressed. Sheet 2 5. Recommend include public road acceptance guidance at this link: https://www.albemarle.org/home/showpublisheddocument/1276/637321324043370000 (Rev. 1) Addressed. 6. Incorporate slopes shown to be less steep than 25%, per approved steep slopes exhibit, recommend legend distinguish newly -designated non -steep slopes as this may aid review, construction, compliance, and limit misunderstandings. (Rev. 1) Addressed. Sheet 5 7. Show and label RW width on Goldsberry Lane and Miranda Crossing. (Rev. 1) Addressed. 8. Coordinate any wetland impact permit or mitigation requirements with Vinny Pero, USACE. (Rev. 1) Addressed. Applicant response (letter d. 3/15/22): `There are no wetland impacts associated with this phase. Anticipated future wetland impacts have/are being coordinated with Vinny Pero, USACE.' 9. Please confirm stop sign placement at intersection of Fowler Street and Odom Court, since Fowler Street presents a more natural through movement, if stop sign is located on Odom Court. (Rev. 1) Addressed. 10. Label attached unit driveway private entrances (PE), and provide VDOT PE detail. (Rev. 1) Addressed, 11. Label lots. (Rev. 1) Addressed. Engineering Review Comments Page 2 of 3 12. Label curbing. (Rev. 1) Addressed. 13. Label all traffic control signs (stop, no parking, speed limit, etc.) (Rev. 1) Addressed. Sheet 6 14. Provide permanent barrier at each end of Odom Court hammerhead to prevent off -road incident. Unbroken unrecoverable slopes lie immediately adjacent to curb at each end of the hammerhead. Permanent barrier may not consist of landscaping only, but may include landscape screening. Recommend VDOT-class permanent GR-2. (Rev. 1) Addressed. 15. Provide and label interim barriers at ends of Fowler Street and Miranda Crossing. (Rev. 1) Addressed. 16. Provide label reference to WP02021-00063 at ends of 18" and 24" HDPE pipes that daylight behind third lot on N side of Odom Court. (Rev. 1) Addressed. Applicant: `Reference to WPO-2021-00063 has been added to plan sheet 6.' As follow-up: Ensure revisions to WP02021-00063 translate to ROAD plan, including proposed easement, ditch, or SWM facility WPO plan revisions. 17. Provide footprint outline and labels of WP02021-00063 SWM facilities, to clarify that HDPE storm pipes do not simply daylight, but discharge to stormwater management facilities. (Rev. 1) Addressed. Also, please see item 16, above. 18. Show and label public drainage easements for any storm pipe located outside public RW. (Rev. 1) Addressed. Also, please see item 16 above. 19. Provide and show roof leader lines since WPO2021-00063 relies on post -developed sheet flow. Roof leader lines need to connect with storm conveyance system. (Rev. 1) Partially addressed. Applicant: `The rear of perimeter lots shall be captured and conveyed to the SWM pond location utilizing ditches, hydraulic analysis ditch sections and private easements provided for ditches.' As follow-up: During WPO plan review meeting 21-Dec 2022 (developer /RGA /JA), ditch /rear roof storm runoff discussed. Roof discharge via `spring -up' style system (discharge to lawn, not splash blocks) to prevent concentrated discharge to slopes is acceptable (provide plan detail). Please ensure surface storm runoff does not cross more than 3 lots. 20. Provide reverse bench and surface water diversion for 40-ft. vertical interval over 3:1 slopes east of Fowler Street along north boundary of parcel. Ref. requirements at 18-4.3.3.C. (Rev. 1) Addressed. Applicant: `A reverse bench has been incorporated into the proposed grading on the east side of Fowler street and labeled on Sheet 6.' Note: Belvedere V contractor is constructing grade at this location on Dunlora Farm parcel under WP0202000034, Amendment #2. [plan under review, most -recent submittal rcvd. 12/16/22] 21. Note especially requirement prohibiting concentrated storm runoff release across fill or cut slopes, which prohibits (roof) downspout release, specifically. Ref. 18-4.3.3.C.4. (Rev. 1) Addressed. Also, please see item 19 above. Sheet 7 22. Revise prop. Storm sewer easement label to read `public drainage easement.' (Rev. 1) Addressed. Also, please see item 16, above. 23. On this or prior sheet, provide and label proposed SWM facility easements. (Rev. 1) Addressed. Also, please see item 16, above. 24. On this or prior sheet, provide and label proposed SWM facility access easements. (Rev. 1) Addressed. Also, please see item 16 above. Sheet 8 25. Typical street section includes Goldsberry Lane and Odom Court, please confirm each of these roads is built with 8" subbase (21A), since sheet 10 indicates Goldsberry Lane has 4" 21A stone. (Rev. 1) Addressed. 26. Fowler Street and Miranda Crossing profiles include tangent sections with more than one grade label; please check and revise as needed (list a single % grade in tangent sections). (Rev. 1) Addressed. 27. Ensure Fowler Street and Miranda Crossing tie with smooth tangent or smooth vertical curve to corresponding sections to be built in Belvedere development. Ref. SUB202100195 ROAD plan. (Rev. 1) Addressed. Engineering Review Comments Page 3 of 3 28. Miranda Crossing profile includes `Intersection fire road' label, please delineate fire road in plan view on sheet 5. (Rev. 1) Addressed. Applicant: `The fire road is not being shown on sheet 5 as it is not to be built for Phase 1' 29. Provide underdrains, VDOT UD-1, at vertical sags and proposed cut/fill transitions, show and label in profile. (Rev. 1) Addressed. Sheet 9 30. Provide Odom Court sight distance easement across lot at NW comer of Int. Fowler Street and Odom Court. May record easement with final subdivision plat. (Rev. 1) Addressed. Sheet 10 31. Provide sight distance easement across 2 lots at NW comer of intersection of Goldsberry Lane and Miranda Crossing. May record easement with final subdivision plat. (Rev. 1) Addressed, Sheet 11 32. 7 or more storm structures require safety slab. Label structures that require VDOT SL-1 (vertical interval between INV OUT and TOP > 12.0'). (Rev. 1) Addressed. 33. STRM 128-130 profile existing grade profile is inconsistent with sheet 8, which shows structure will be in fill, please check and revise as needed. (Rev. 1) Addressed. 34. If pipe between Str. 128 and 130 is in fill, recommend revise pipe slope since any deflection may require constructive remedy difficult or expensive to perform once storm conveyance system is complete. 0.5% pipe slope, the minimum, affords little leeway for error of in a fill section. (Rev. 1) Addressed. 35. STRM 120-126: Recommend increase proposed 0.50% pipe slope, since pipe is in fill section. (Rev. 1) Addressed. Sheet 12 36. VDOT LD-204: Revise inlet length/s to avoid spread > Y: travel lane width. Several inlets are insufficient length. (Rev. 1) Addressed. As follow-ua, though not required, Engineering recommends increase length of 2.5' /4' inlets where L/Lt < 1.0 as a matter of conservative design to limit carryover as much as possible. Sheet 13 37. See comment at items 19 and 21 concerning roof runoff, leader lines, storm conveyance, and sheet flow. Revise linework to provide capture and conveyance of entire roofscape since concentrated downspout runoff may not release to cut or fill slopes. Note: splash blocks do not transition concentrated flow to sheet flow. (Rev. 1) Partially addressed. Applicant: `Rear yard swales shall convey disturbed areas to the SWM pond. Private easements added for perpetual HOA maintenance of ditches.' Asfollow-up: Items discussed during 21-Dec 2022 WPO plan review meeting. Capture of entire roofscape is not required. Engineering anticipates revised `pop-up' rear roof design storm release to lawn areas in certain locations in lieu of yd. inlet capture /convenance, or splash blocks (short-circuited in build stage by drain file discharge to slopes). Pop-up detail requested for WPO /Road plans to avoid concentrated discharge to slopes at rear of lots via drain tile (often) otherwise installed during lot -to -lot build phase of development. SUB202100161 Dunlora Farm Phase 1 ROAD Plan 122622revI