HomeMy WebLinkAboutSDP202200073 Correspondence 2022-12-29December 14, 2022 MEMORANDUM To: Ms. Rebecca Ragsdale Planning Manager County of Albemarle, Virginia From: Mr. Eric Woolley, PE Woolley Engineering Regarding: Little Explorers Discovery School SDP202200028 (TM 56A2-01 P 16) Initial Site Plan — Conditional Approval Action Letter Responses to comments from County Staff With this memo, we are responding to the comments that were directed to our office following the review and conditional approval of our Initial Site Plan for the Little Explorers Discovery School project located at 5762 Tabor Street in Crozet. The conditional approval letter with comments was received in written format and dated August 3, 2022. Below, we have provided our responses to the correlated comments as numbered on the action letter. Albemarle County Planning Services (Planner) — Rebecca Ragsdale 1. a. This comment has been disregarded per the virtual discussion meeting with County Planning on August 29, 2022. The DCD has setback requirements within the zoning. b. Property information for the abutting properties located across the street has been added to note 8 on sheet C 1.0. 2. a. Floor area tabulations for each proposed building has been added to C1.0 under general note 15. b. The proposed use for each building on the property has been added to the layout plan on sheet C3.0. c. The proposed use has been updated on sheet C 1.0 under general note 6 to state Child Day Center with parking. 3. Additional right-of-way linework and dimensions have been added to all applicable plan sheets. 4. All existing utility easements can be seen on the layout plan, sheet C3.0 in the plan set. The majority of utilities located on -site are laterals that are not located within an easement. 5. A drainage easement is being proposed for maintenance of stonnwater runoff leaving the site. The linework can be seen on the layout plan, sheet C3.0. There are no other proposed easements at this time. 6. Additional dimensions have been added to the layout plan on sheet C3.0. 7. This comment has been acknowledged. 8. This comment has been acknowledged. A WPO plan will be submitted soon for review. 9. Additional dimensions have been added to the angled parking spaces. 10. Notification from Dominion Power is being pursued and will be forwarded once received. 11. The front of the lot, where the proposed parking is located, is screened with existing landscape that is being preserved. The rear of the lot, which is a play yard, is screened with an existing WOOLLEY ENGINEERING 210 5th Street NE (434) 973-0045 Charlottesville, Virginia 22902 M WOOLLEY ENGINEERING fence that is 6' in height. a. Downtown Crozet District requires three street trees. Plant size and details are now included on sheet L 1.0 in the plan set. b. A planting plan schedule has been added to sheet L1.0. c. This comment has been acknowledged. 12. This comment has been acknowledged. Additional information about the proposed lighting can be found on plan sheet SL 1.0. Additional callouts have been added to all existing site features for clarification. Albemarle County Engineering Services (Engineer) — Emily Cox 1. This comment has been acknowledged. A WPO plan will be submitted as a separate submission. 2. All seals have been signed and dated. 3. A note stating that the topography for the site has been field -verified has been added to sheet C1.0. 4. Additional linework, dimensions, and callouts have been added to the right-of-way along both Tabor Street and High Street.\ 5. This comment has been acknowledged. Additional drainage information will be included in the WPO plan submission. 6. A special exception is currently being pursued to remove the sidewalk requirement from the project due to unique site characteristics. If the special exception is not approved then additional right-of-way will need to be created to contain the proposed sidewalk. 7. This comment has been acknowledged. Proposed drainage and SWM facility easement linework can be found on the layout plan, sheet C3.0 within the plan set. 8. Adjacent property owner permission has been provided to Ownership and documentation is being prepared and will be forwarded upon receipt. 9. Sight distance lines have been added to sheet C3.0 in the plan set. 10. The angled parking travel aisle has been expanded to a 16' width to meet the Albemarle County specifications for 60 degree angled parking. OR A special exception to allow a narrower one- way drive aisle has been submitted under separate letterhead. 11. The proposed drive aisles are for one-way travel. Callouts have been added to the plan for clarification. Albemarle County Architectural Review Board (ARB) — Margaret Maliszewski 1. It has been acknowledged that ARB review will not be necessary for this project due to the location of the entrance corridor overlay and the proposed work. Albemarle County Building Inspections — Betty Slough 1. No objection noted on review comment memo. Albemarle County Service Authority — Richard Nelson 1. This comment has been acknowledged. RWSA must accept the sewer flow for this project. The required RWSA information has been provided for coordination. 2. The existing water meter will be relocated outside of the proposed entrance. 3. A change in fixture count has been submitted with the building permit. Virginia Department of Transportation — John Wilson 1. Trip generation data has been added to general note # 16 on plan sheet C 1.0. 2. Please find the right tum/taper analysis for the site attached to this memorandum. The analysis utilizes VDOT published traffic numbers, anticipated trip generation numbers, and the VDOT standards found in Appendix F of the Access Management Design Standards for Entrances and Intersections. The analysis determined that a right turn and taper are not warranted for the M WOOLLEY ENGINEERING proposed use of the site. 3. The sight lines for the entrance and sight distance profile can be found on plan sheet C3.0, the sight distance profile can be found on sheet C5.1. 4. The mill and repave limits have been expanded to meet the adjacent travel lane. The revised hatching for this area can be seen on sheet C3.0. 5. Management of Traffic details have been added to the detail sheet on C7.0 for "Typical Traffic Control — Lane Closure on a Two -Lane Roadway Using Flaggers". 6. Pre -construction and post -construction drainage calculations will be included in the WPONSMP plan submission. This plan will be submitted at a later date. 7. The existing right-of-way linework has been added to applicable plan sheets. The right-of-way linework now includes boundaries for right-of-way located across High Street and Tabor Street. 8. The subject property falls within the Downtown Crozet District (DCD) Zoning which requires an 8' width sidewalk. A variance is currently being pursued to determine whether this requirement will be added to the site plan. 9. This comment has been acknowledged. Rivanna Water and Sewer Authority— Dyon Vega 1. The requested information has been provided to the ACSA. Albemarle County Department of Fire Rescue — Howard Lagomarsino 1. The requested note has been added to sheet C 1.0 under general construction note # 10 K. 2. The requested note has been added to sheet C 1.0 under general construction note # 10 L. 3. The requested note has been added to sheet C 1.0 under general construction note # 10 M. 4. The requested note has been added to sheet C 1.0 under general construction note # 10 N. 5. The requested note has been added to sheet C 1.0 under general construction note # 10 O. 6. The requested note has been added to sheet C 1.0 under general construction note # 10 P. 7. The requested note has been added to sheet C 1.0 under general construction note # 10 Q. 8. The requested note has been added to sheet C 1.0 under general construction note # 10 R. I hope that these responses, in combination with the revised site plan have satisfied the deficiencies as noted in your comment memorandum. Please do not hesitate to call with any questions or concerns. Thank you for your time and consideration. Sincerely, Cl Eric Woolley, PE Attached: (1) Final Site Plan Application (1) Final Site Plan Checklist (1) Electronic PDF Copy of the Final Site Plan Set (1) Special Exception for Ch. 18 Sec. 4.12.16 (1) Special Exception for Ch. 18 Sec. 20B.7.A. (1) Turn Lane Warrant Documentation Cc: Christi Gillette, Owner — Little Explorers Discovery School 3 Final Site Development Plan Checklist Project Name: Little Explorers Discovery School Firm: Woolley Engineering This checklist must be completed, signed and submitted with the application. The information contained in this checklist reflects the contents of the Section 32 of Chapter 18 of the Code of the County of Albemarle also known as the Site Plan Ordinance as of July 8, 2015. The applicant is responsible for ensuring that no revisions to the Ordinance have occurred since preparation of this document This final site plan has: Id an initial site plan that was approved for the development and it remains valid, SDP - 20 2 - 00028 Id satisfied all of the requirements of section 32.6 below, and is satisfied all of the conditions delineated in the letter provided under section 32.4.2.5(c) required to be satisfied prior to submitting the final site plan. Id Authorized preparer. 8 The plan, and any amendments to a plan, is prepared and sealed, signed and dated by one of the following ❑ An architect licensed to practice in the Commonwealth of Virginia. G3 A professional engineer licensed to practice in the Commonwealth of Virginia. ❑ A land surveyor licensed to practice in the Commonwealth of Virginia. ❑ A certified landscape architect licensed to practice in the Commonwealth of Virginia. 8 Number of copies when first submitted. Id Provide the number of copies as directed in the Initial Site Plan approval letter 8 One (1) reduced copy of the plan no larger than eleven (11) by seventeen (17) inches in size. 8 Scale and size. Id The plan is prepared to the scale of one (1) inch equals twenty (20) feet or larger, or to another scale approved by the agent in a particular case. ❑ Other scale approved - one (1) inch equals () feet, by Id No sheet exceeds forty-two (42) inches by thirty-six (36) inches in size. 8 The plan IS prepared on one (1) sheet. OR ❑ The plan IS prepared on more than one (1) sheet and match lines clearly indicate where the several sheets join. Id The top of each sheet is approximately ld North or ❑ East ® Dimensions. The plan is dimensioned to at least the following standards for accuracy: la Boundary, setback and zoning lines: Within one one -hundredth (0.01) of a foot. m Existing contours: Within one-half (1/2) of the contour interval required in section 32.6.2(c). m Proposed contours: Within one (1) foot horizontally and vertically. m Spot elevations: Within one -tenth (0.10) of a foot. la Existing critical structures including utilities and other topographic features: Within two (2) feet, provided that for critical structures, which include, but are not limited to, gas lines, other utilities, pipes, conduits, walls and buildings to be preserved, within one -tenth (0.10) of a foot. ® Proposed structures, roads, parking lots and other improvements: Within one one -hundredth (0.01) of a foot. REVISED 02/8/2021 Page 1 of Albemarle County - Final Site Plan Checklist Site Plan Ordinance Section 32.6 - Contents offtnal site plan In addition to containing all of the information required to be on an initial site plan, as provided in section 32.5, a final site plan shall contain the following: Id Demonstrate compliance with chapter. Specific written schedules or notes as necessary to demonstrate that the requirements of this chapter are satisfied. Id Proposed grading. Id Proposed grading (up to twenty [20] percent slope, maximum two [2] foot contours; over twenty [20] percent slope, maximum five [5] foot contours). Id Water and sewer facilities. Id Detailed plans for proposed water and sewer facilities, including all pipe sizes, types and grades; Id proposed connections to existing or proposed central water supplies and central sewage systems; Id location and dimensions of proposed easements and whether they are to be publicly or privately maintained; Id profiles and cross sections of all water and sewer lines including clearance where lines cross; Id all water main locations and sizes; valves and fire hydrant locations; Id all sewer appurtenances by type and number; Id the station on the plan to conform to the station shown on the profile and indicate the top and invert elevation of each structure. Id Drainage and grading plans. Id Detailed construction drainage and grading plans: Id Profiles of all ditches and channels whether proposed or existing, showing existing and proposed grades, and invert of ditches, cross pipes or utilities; typical channel cross sections for new construction; and actual cross sections for existing channels intended to remain; Id Profiles of all storm sewer systems showing existing and proposed grades; Id Plan view of all drainage systems with all structures, pipes and channels numbered or lettered on the plan and profile views. Show sufficient dimensions and bench marks to allow field stake out of all proposed work from the boundary lines; Id A drainage summary table for culverts, storm sewer and channels as described in the following example: Structure Description Length Invert Invert Slope Remarks Number In Out 1 42" RCP 50' 24.50 424.00 100.00% Provide Class 111 2, EW 2 DI- 3B L=8 26.00 432.00 - IS-1 To 3 PG-2A 400' 420.00 400.00 5.00% D=12" 4 Grade 200' 420.00 415.00 2.50% D=18" Swale Id A legend showing all symbols and abbreviations used on the plan; Id General notes, typical sections, and details of all items not covered by Virginia Department of Transportation standard drawings; and Id Flood plain limits for the one hundred (100) year storm for all watercourses with an upstream drainage area of fifty (50) acres or more provided that the county engineer may waive this requirement for drainage areas of less than one hundred (100) acres upon determining that the information is unnecessary for review of the proposed development. REVISED 02/8/2021 Page 2 of 4 Albemarle County - Final Site Plan Checklist Id Street sections. ❑ Typical street sections together with specific street sections where street cut or fill is five (5) feet or greater; ❑ centerline curve data; Id radius of curb returns or edge of pavement; Id location, type and size of proposed ingress to and egress from the site together with culvert size; ❑ symmetrical transition of pavement at intersection with existing street; ❑ the edge of street surface or face of curb for full length of proposed street; ❑ when proposed streets intersect with or adjoin existing streets or travelways, both edges of existing pavement or travelway together with curb and gutter indicated for a minimum of one hundred (100) feet or the length of connection, whichever is the greater distance. Id Public facilities and utilities. Id All public facilities, utility and drainage easements outside the right-of-way of public streets, provided that new easements may be generally shown and accurately dedicated by separate plat. Id All water and sewer facilities to be dedicated to public use and the easements for those facilities and shall be identified by a statement that the facilities are to be dedicated to the Albemarle County Service Authority. Id Signature panel. Id Signature panel for signature by each member of the site review committee. Id Parking and loading areas. Id For all parking and loading areas, indicate the Id size, Id angle of stalls, id width of aisles and specific number of spaces required and provided, and Id method of computation. Indicate type of surfacing for all paved or gravel areas. Id Landscape plan. Id A landscape plan that complies with section 32.7.9 Id Outdoor lighting. Id Outdoor lighting information including Id a photometric plan with Id location, description, and photograph or diagram of each type of outdoor luminaire. Id Recreational facilities. Id Specifications for recreational facilities. Dam break inundation zones; engineering study and mapping information. If the proposed development is located wholly or partially within a dam break inundation zone, the developer shall submit with the final site plan the following: ❑ a. Engineering study. If the Virginia Department of Conservation and Recreation determines that a plan of development proposed by a developer would change the spillway design flood standards of an impounding structure pursuant to Virginia Code § 10.1-606.3 , the developer shall submit an engineering study in conformance with the Virginia Soil and Water Conservation Board's standards under the Virginia Dam Safety Act in Virginia Code § 10.1-604 et seq. and the Virginia Impounding Structure regulations in 4VAC50-20-10 et seq. The engineering study shall be reviewed and acted upon by the Virginia Department of Conservation and Recreation as provided in Virginia Code § 15.2- 2243.1. ❑ b. Mapping information. The developer shall provide the dam owner, the county, and any other affected localities with information necessary for the dam owner to update the dam break inundation zone map to reflect any new development within the dam break inundation zone following completion of the development. REVISED 02/8/2021 Page 3 of Albemarle County - Final Site Plan Checklist In addition to the items required by the ordinance, Albemarle County Engineer, the Virginia Department of Transportation, the Albemarle County Service Authority, and the Thomas Jefferson Health District require these items on plans submitted for final site plan approval. Plans will not be rejected if these items are not present, but they are required for approval. These items are provided in an effort to communicate all final site plan comments. id 1. Reference the benchmarks used for surveys. (Albemarle County Engineering Policy) id 2. Indicate the available sight distance for entrances and left turn lanes. (Albemarle County Engineering Policy) ® 3. Label the maximum height of all retaining walls. (Albemarle County Engineering Policy) ® 4. Provide copies of off -site easements, or letters of intent to grant them from off -site property owners. (Albemarle County Engineering Policy) Id 5. Show and label stream buffer limits. (Water Protection Ordinance, WPO) id 6. Indicate the deed book and page reference for all existing utility easements located on the property. (Albemarle County Service Authority) ❑ 7. Tier 3 - Draft or Final Groundwater Management Plan (WPO Section 17-403) ❑ 8. Tier 4—Aquifer testing work plan (WPO Section 17-403) Read and Sign In representing the above referenced firm submitting this plan for final approval, I hereby sate that, to the best of my knowledge, the attached plan contains all information required by this checklist. 12/14/2022 tgna re of Owner, Contract Purchaser, gent Date Sarah Gerke, EIT 434-973-0045 Print Name Daytime phone number of Signatory REVISED 02/8/2021 Page 4 of 4 December 14, 2022 TURN LANE WARRANT DOCUMENTATION To: John Wilson, PE Assistant Resident Engineer -Land Use VDOT-Charlottesville Residency From: Mr. Eric Woolley, PE Woolley Engineering Regarding: SDP202200028 Little Explorers Discovery School: 5762 Tabor Street Albemarle County, Virginia The below right turn lane warrant documentation has been prepared in support of the Little Explorers Discovery School site plan. The project is located at 5762 Tabor Street, Crozet, VA 22932. The project includes adding additional parking to the site, select site improvements, and improving the entrance to the site. Warrant for Right Turn Lane: Source: VDOT Access Management Design Standards for Entrances and Intersections — Appendix F 2022 Published VDOT Traffic Information ITE Trip Generation Manual — 10a' Edition Assumptions: • ITE Trip Generation Code 565 for Daycare Center • Design speed of 30 mph for Tabor Street (25 mph posted speed) • 2,505 square feet of gross floor area for daycare use • (2,505 square feet / 1,000 square feet) x 11.12 = 28 trip ends/day (PM Weekday Peak) • We are utilizing the k-factor 0.1 as an average to multiply the daycare center code 565 trip ends/day to convert it to peak hour trip ends: 28 x 0.1 = 2.8 or 3 trip ends/peak hour • Assumed value of 11 % for K x D since there are no published values available. WOOLLEY ENGINEERING 210 5th St. NE (434) 973-0045 Charlottesville, Virginia 22902 WOOLLEY ENGINEERING ITE TYPE OF INDEPENDENT NO. OF AVERAGE AVERAGE AVERAGE CODE DAY VARIABLE UNITS RATE LISTED VEHICLE VEHICLE IN ITE TRIP ENDS TRIP ENDS CALCULATED CALCULATED BY DAY BY HOUR (WHOLE (WHOLE NUMBER NUMBER 565 WEEKDAY 1,000 SF GFA 2.51 11.12 28 3 Assumed trip origination: o We assume trip origination to the Daycare Center as % travelling from Crozet Ave and turning left into the Daycare Center (2 vph). o We assume trip origination to the Daycare Center as %2 travelling from High Street and turning left into the Daycare Center (2 vph). Road Volume Calculations: Street: Tabor Street from Crozet Ave to High Street AADT: 3,700 K-Factor (K): unpublished Direction Factor (D): unpublished PHV= AADT x K x D Peak Hour Volume= 3,700 x 0.11 = 407 vph Conclusions: The VDOT warrants for right turn lane treatment graph is shown below utilizing the above calculated values. Based on the published VDOT Traffic Values and the above calculations with an estimated 2 vph turning right into the daycare center, no turn lanes or tapers are warranted. WOOLLEY ENGINEERING Warrant for Right Turn Lane Grauh: I:iF2iU� oe Published VDOT Traffic Values Estimated 2 vph right turns into property = 407 vph I (Assumed 1/2 trip ends originating from 120 20 [RADIUS REQUIRED NO TURN LANES OR TAPERS REQUIRED PHV APPROACH TOTAL, VEHICLES PER HOUR FIGURE 3-26 WARRANTS FOR RIGHT TURN TREATMENT (2-LANE HIGHWAY) Appropriate Radius required at all Intersections and Entrances (Commercial or Private). LEGEND PHV- Peak Hour Volume (also Design Hourly Volume equivalent) Adiustment for Riaht Turns For posted speeds at or under 45 mph, PHV right turns > 40, and PHV total < 300. Adjusted right turns = PHV Right Turns - 20 If PHV is not known use formula: PHV = ADT x K x D K = the percent of AADT occurring in the peak hour D = the percent of traffic in the peak direction of flow Note: An average of 11 % for K x D will suffice When right turn facilities are warranted, see Figure 3-1 for design criteria.' Rev. 1/15 C