BRICKS AND MINIFIGS RENOVATION
2050 BOND STREET, SUITE 1 10, CHARLOTTESVILLE, VA 22901
100% CONSTRUCTION DOCUMENTS
11/08/2022
LOCATION MAP
Sa�yo�`rm
1PQ Iluk4
reat�N r.eomve e
,rM�Sn
1
I/
11 4\«pb
. cosT<o wno�eae�e �+
'lop
The StwpS at StancTQ
•;,� wT
_ s"mir swore
na. as Sbrwa Center
rb
i
� � v
1 Po c
r�
2050 BOND STREET
CHARLOTTESVILLE, VA 22901
VICINITY MAP
2
BRICKS AND MINIFIGS, SUITE 110
PROJECT DESCRIPTION AND SCOPE OF WORK
THIS PROJECT CONSISTS OF AN INTERIOR RENOVATION OF LANDLORD PROVIDED
TENANT SPACE AT THE SHOPS AT STONEFIELD IN CHARLOTTESVILLE, VA. THIE
RENOVATION CONSISTS OFANEW RETAIL STORE FOR THE SALE OF LEGOS AND SIMILAR
AND ASSOCIATED PRODUCTS, A PARTY ROOM FOR HOSTING SMALL GROUPS OF PEOPLE
WITH TABLES AND CHAIRS AND BACK OF HOUSE AREAS INCLUDING RESTROOMS AND
STOCK I STORAGE ROOMS FOR STORAGE OF PRODUCTS NOT ON DISPLAY.
THE RENOVATION WILL PRIMARILY LEAVE THE EXISTING SPACE UN -ALTERED WITH THE
EXCEPTION OF ADDING A 314 HEIGHT PARTITION TO CREATE A NEW EMPLOYEE AREA AS
PART OF THE BACK -OF -HOUSE. EXISTING FINISHES WILL RECEIVE A NEW COAT OF PAINT
WHERE INDICATED.
TWO EXISTING ACCESSIBLE RESTROOM WILL BE WITHIN
THIS SPACE, AND WILL BE AVAILABLE TO THE PUBLIC. A NEW DRINKING FOUNTAIN
COMPLYING WITH ADA REQUIREMENTS WILL BE PROVIDED IN THE EMPLOYEE AREA WITH
SIGNAGE INDICATING THAT ACCESS TO THE PUBLIC IS AVAILABLE UPON REQUEST.
EXISTING SINKS WITHIN BACK -OF -HOUSE AREAS ARE TO REMAIN AND WILL SERVE TO
SUPPORT THE STORAGE USE AS THE MERCHANDISE THAT IS SOLD I USED FOR PARTIES
REQUIRES CLEANING AFTER USE AND BEFORE STORING. THERE WILL BE NO
KITCHENETTE OR SIMILAR TYPE OF ROOM FOR THE PROJECT.
EXISTING FIRE SUPPRESSION, MECHANICAL AND ELECTRICAL WORK WILL BE LEFT
UNTOUCHED. ANY FUTURE ALTERATION TO THESE SERVICES WOULD BE FILED UNDER A
SEPARATE PERMIT REQUEST.
3
THIS PROJECT CONSISTS OF THE FOLLOWING WORK:
LIMITED LOCAL DEMOLITION ONLY AS NEEDED FOR NEW CONSTRUCTION
NEW INTERIOR PARTITIONS & DOORS
NEW FLOOR FINISHES AS INDICATED
NEW PAINT FINISHES
NEW PLUMBING EQUIPMENT AND CONNECTION (DRINKING FOUNTAIN)
NEW LED EXIT SIGNS TO MATCH EXISTING
NEW FURNITURE, FURNISHINGS AND MERCHANDISE SHELVING
NEW TENANT SIGNAGE (UNDER SEPARATE PERMIT)
EXISTING WORK NOT ALTERED WITH THIS RENOVATION
EXISTING TENANT SPACE (ENVELOPE AND DEMISING WALLS) PROVIDED BY LANDLORD
EXISTING LANDLORD STOREFRONT
EXISTING ACCESSIBLE RESTROOM(S) BY LANDLORD
EXISTING ELECTRICAL PANEL
EXISTING AIR HANDLING UNITS
EXISTING I SUPPLEMENTED WATER HEATER
EXISTING I MODIFIED AIR DISTRIBUTION (DUCTWORK & DIFFUSERS)
EXISTING SPECIALTY OVERHEAD COILING DOOR
EXISITNG CEILINGS (CEILING GRID & TILES AND GWB SOFFITS)
EXISTING LIGHTING AS SCHEDULED
EXISTING FIRE PROTECTION SPRINKLER SYSTEM
ANY ALTERATIONS PERFORMED ON ABOVE WORK TO BE FILED UNDER SEPARATE PERMIT
4
DRAWING LIST
G-001
COVER
G-002
GENERAL NOTES
LS-101
LIFE SAFETY AND CODE ANALYSIS
AD-101
DEMOLITION PLANS
AD-102
EXISTING CONDITIONS
A-101
FLOOR PLANS
5
DESIGN
DEVELOP
ARCHITECTURE • VISUALIZATION • ENTITLEMENT
www.designdevelopllc.com
ARCHITECT
Design Develop, LLC
418 East Main Street
Charlottesville, VA 22902
434.443.4045
Contact: Khanh Uong, RA
Email: kuong@designdevelopllc.com
NO. DESCRIPTION DATE
BRICKS AND MINIFIGS
RENOVATION
100% CONSTRUCTION
DOCUMENTS
2050 BOND STREET, SUITE 110,
CHARLOTTESVILLE, VA 22901
COVER
DATE: 11 /08/2022
DRAWN BY: MM
CHECKED BY: BP
G-001
0
N
O
n.
S
o
0
�?
0
N
N
O
C
1 2 3 4 5
GENERAL CONTRACTOR NOTES
ACCESSIBILITY NOTES
DEMOLITION NOTES
GENERAL NOTES
LANDLORD NOTES
1. THE G.C. SHALL REVIEW ALL DOCUMENTS, VERIFY ALL DIMENSIONS, AND CONFIRM THAT THE WORK CAN BE
BUILT AS SHOWN. IN THE EVENT OF ANY CONFLICTS OR OMISSIONS WITHIN THE DRAWINGS, G.C. TO
1.INALL BUILDINGS, FLOORS OFAGNENSTORY SHALL BEACOMMON LEVEL THROUGHOUT, ORSHALL
BE CONNECTED BY PEDESTRIAN RAMPS, PASSENGER ELEVATORS OR SPECIALACCESS LIFTS.
1. THE TERM "PATCH AND REPAIR" SHALL BE DEFINED AS: THE PROCESS OF REPAIRING FLOOR, WALL, OR
CEILING SURFACES THAT HAVE BEEN DAMAGED OR AREADJACENT TO DEMOLISHED CONSTRUCTION. THE
1.CONTRACTOR T0COMPLY WITH CODES, LAWS, ORDINANCES, RULES, AND REGULATIONS OF PUBLIC
AUTHORITIES GOVERNING THE WORK.
1.TENANTSGENERAL CONTRACTOR SHALL SUBMITACONSTRUCTION DEPOSIT WITH LANDLORD'S ONSITE
REPRESENTATIVE PER CENTER REQUIREMENTS.
CONTACT TENANTS PROJECT MANAGER 8 ARCHITECT FOR CLARIFICATION PRIOR TO THE PERFORMANCE
REPAIR SHALL INCLUDE, BUT NOT BE LIMITED T0: FILLING VOIDS SOLID WITH CONCRETE, PREPARING
C
A
I
THE DESIGN AND CONSTRUCTION OF ALL STRUCTURES SHALL COMPLY WITH THE CURRENT VIRGINIA UNIFORM STATEWIDE BUILDING CODE:
1. CURRENT BUILDING CODES
THE ALBEMARLE COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT ENFORCES THE FOLLOWING APPLICABLE CODES AND STANDARDS CORRESPONDING TO THE CURRENT VUSBC:
2018 VIRGINIA EXISTING BUILDING CODE (VCC) [2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) WITH STATE AMENDEMENTS]
2018 VIRGINIA CONSTRUCTION CODE (VCC) [2018 INTERNATIONAL BUILDING CODE (IBC) WITH STATE AMENDEMENTS]
2018 VIRGINIA PLUMBING CODE (VPC) 12018 INTERNATIONAL PLUMBING CODE (IPC) WITH STATE AMENDEMENTS]
2018 VIRGINIA MECHANICAL CODE (VMC) [2018 INTERNATIONAL MECHANICAL CODE (IMC) WITH STATE AMENDMENTS]
2018 VIRGINIA FUEL GAS CODE (VFGC) 12018 INTERNATIONAL FUEL GAS CODE (IFGC) WITH STATE AMENDMENTS]
2018 VIRGINIA ENERGY CONSERVATION CODE (VECC) [2018 INTERNATIONAL ENERGY CONSERVATION CODE (VECC) WITH STATE AMENDEMENTS]
2017 NATIONAL ELECTRICAL CODE (NFPA 70)
2018 VIRGINIA PROPERTY MAINTENANCE CODE [2018 INTERNATIONAL PROPERTY MAINTENANCE CODE (VPMC) WITH STATE AMENDEMENTS]
2018 VIRGINIA STATEWIDE FIRE PREVENTION CODE [2018 INTERNATIONAL FIRE CODE (IFC) WITH STATE AMENDEMENTS]
STANDARDS REFERENCED IN 2018 VIRGINIA CONSTRUCTION CODE
2016 NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS
2016 NFPA 72 NATIONAL FIRE ALARM CODE
20091CC At 17.1 ACCESSIBLE AND USABLE BUILDING AND FACILITIES
ADDITIONAL STANDARDS RFERENCED:
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
EFFECTIVE MARCH 15, 2012
2. BUILDING INFORMATION - EXISTING BUILDING AND TENANT:
- BUILDING CODE FOR EXISTING CONSTRUCTION: VUSBC 2012
-OVERALL BUILDING CONSTRUCTION CLASSIFICATION: TYPE IIB (NON COMBUSTIBLE, UNPROTECTED)
- SEISMIC ZONE:1
- SPRINKLERS: FULLY SPRINKLERED TO MEET REQUIREMENTS OF NFPA 13 (2010)
- FIE ALARM: PROVIDED TO MEET REQUIREMENTS OF NFPA 72 (2010)
- CURRENT TENANT DESIGN DATA:
- OCCUPANCY CLASSIFICATION: ASSEMBLY (UNCONCENTRATED - TABLES AND CHAIRS) USE GROUP A-2
-AREA FOOTPRINT:2,170 SQUARE FEET
- NUMBER OF STORIES:1
-CALCULATED OCCUPANT LOAD:108 PEOPLE
- EXITS PROVIDED: 2 (2 REQUIRED)
- MAXIMUM TRAVEL DISTANCE: I10'-V
- MAXIMUM DIAGONAL OF SPACE: 65'4"
- REMOTENESS BETWEEN EXITS: 30'-2" PROVIDED (16'4' REQUIRED)
- EGRESS WIDTH PROVIDED:120"
- EGRESS WIDTH AT MAIN EXIT: 72"
- EGRESS WIDTH AT SECONDARY EXIT: 48"
- REQUIRED TENANT FIRE RATED SEPARATION:1 HOUR
- EXTERIOR WALL FIRE RATING REQUIRED: NIA
3. BUILDING CODE ANALYSIS - NEW TENANT WORK:
- BUILDING CODE FOR NEW WORK: VUSBC 2018 (SEE CODES LISTED ABOVE)
- OVERALL BUILDING CONSTRUCTION CLASSIFICATION: TYPE IIB (NON COMBUSTIBLE, UNPROTECTED)
- SEISMIC ZONE:1
-SPRINKLERS: FULLY SPRINKLERED TO MEET REQUIREMENTS OF NFPA 13 (2010)
- FIE ALARM: PROVIDED TO MEET REQUIREMENTS OF NFPA 72 (2010)
- NEW TENANT DESIGN DATA:
-OCCUPANCY CLASSIFICATION: MIXED NON -SEPARATED OCCUPANCIES (VCC 508.3) OF MERCANTILE (RETAIL) USE GROUP M AND ASSEMBLY USE GROUP A-3
-AREA FOOTPRINT:2,170 SQUARE FEET
- NUMBER OF STORIES:1
-CALCULATED OCCUPANT LOAD: 54 PEOPLE (SEE LIFE SAFETY FLOOR PLAN)
- EXITS PROVIDED: 2 (2 REQUIRED)
- MAXIMUM TRAVEL DISTANCE: 86'-7'
- MAXIMUM COMMON PATH OF TRAVEL: 30'.1"
- LONGEST DEAD-END CORRIDOR: 8'-8"
- MAXIMUM DIAGONAL OF SPACE: 65'A"
- REMOTENESS BETWEEN EXITS: 32'-8" PROVIDED (16'-4" REQUIRED)
- EGRESS WIDTH PROVIDED:108"
- EGRESS WIDTH AT MAIN EXIT: W'
- EGRESS WIDTH AT SECONDARY EXIT: 44"
- REQUIRED TENANT FIRE RATED SEPARATION: i HOUR
- EXTERIOR WALL FIRE RATING REQUIRED: NIA
4. BUILDING CODE ANALYSIS - MODIFICATIONS TO EXISTING BUILDING:
- BUILDING CODE FOR MODIFICATIONS TO EXISTING BUILDING: VEBC 2018 (SEE CODES LISTED ABOVE)
- CHANGE IN OCCUPANCY: YES (FROM ASSEMBLY USE GROUP A-2 TO MIXED MERCANTILE USE GROUP M AND ASSEMBLY USE GROUP A-3)
-ALL NEW WORK SHALL COMPLY WITH 2O18 VUSBC REQUIREMENTS FOR USE GROUP M AND A
-VEBC TABLE 705.2 MEANS OF EGRESS HAZARD CATEGORIES
- EXISTING A-2 OCCUPANCY CLASSIFICATION: RELATIVE HAZARD LEVEL 3
- NEW M OCCUPANCY CLASSIFICATION: RELATIVE HAZARD LEVEL 3 / NEW A-3OCCUPANCY CLASSIFICATION: RELATIVE HAZARD LEVEL 3
- NEW OCCUPANCY CLASSIFICATIONS ARE CONSIDERED EQUIVALENT HAZARD LEVEL TO EXISTING
5. NEW WORK BUILDING CODE REQUIREMENTS FROM 2018 VCC FOR USE GROUP A (MOST RESTRICTIVE OCCUPANCY FOR A MIXED NON -SEPARATED M /A):
- EXIT ACCESS TRAVEL DISTANCE (VCC 1017.2): 250 FEET MAXIMUM
-COMMON PATH OF TRAVEL (VCC TABLE 1006.2.1):75 FEET MAXIMUM
. DEAD END CORRIDORS (VCC 1020.4): 20 FEET MAXIMUM
- NUMBER OF EXITS REQUIRED (VCC SECTION 1006): OCCUPANT LOAD BETWEEN 50 AND 500 REQUIRES MINIMUM OF TWO EXITS
- NUMBER OF ACCESSIBLE MEANS OF EGRESS REQUIRED (VCC 1009.1): 2
- EXIT REMOTENESS, FOR SPRINKLERED BUILDING (VCC 1007.1.1 EXCEPTION 2):NOT LESS THAN 114 THE MAXIMUM OVERALL DIAGONAL DIMENSION OF AREA SERVED
- MINIMUM WIDTH OF EGRESS COMPONENTS REQUIRED (VCC 1005.3 AND 1020.2):
- DOORS (VCC 1005.3.2.): 32 INCHES
-STAIRS (VCC 1005.3.1): 44INCHES I ACCESSIBLE ROUTE=48INCHES CLEAR MINIMUM (VCC 1009.3)
-CORRIDORS: (VCC 1020.2):36INCHES (X < 50OCCUPANTS) 44INCHES (X> 50OCCUPANTS)
- INTERIOR FINISHES (VCC TABLE 803.13): BASED ON RESIDENTIAL GROUP R-1, MATERIALS FOR THE ENTIRE BUILDING WILL MEET THE FOLLOWING CRITERIA:
- ROOM WALLS AND CEILINGS: CLASS C; 75 - 200 FLAME SPREAD; 0 - 450 SMOKE -DEVELOPED
- EXIT ACCESS CORRIDORS WALLS AND CEILINGS: CLASS C; 75 - 200 FLAME SPREAD; 0 - 450 SMOKE -DEVELOPED
-VERTICAL EXITS WALLS AND CEILINGS: CLASS B; 26- 75 FLAME SPREAD; 0-450 SMOKE -DEVELOPED.
- EXIT ENCLOSURE FLOOR FINISH: CLASS II; RADIANT FLUX NOT LESS THAN 2.2 KWIMA2 BUT LESS THAN 4.5 KWIMA2 (VCC 804.4.2)
- COMBUSTIBLE DECORATIVE MATERIALS (VCC 806.2 EXCEPTION 4): THE AMOUNT OF COMBUSTIBLE FABRIC PARTITIONS SUSPENDED BY THE CEILING AND NOT SUPPORTED BY THE FLOOR SHALL COMPLY WITH NFPA 701 OR
NFPA 289AND SHALL NOT BE LIMITED
- COMBUSTIBLE TRIM OTHER THAN FOAM PLASTIC (VCC 806.7): CLASS C; 75-200 FLAME SPREAD; 0- 450 SMOKE -DEVELOPED.
ALL MATERIALS USED IN THE INSTALLATION OF NEW WORK MUST BE NON-COMBUSTIBLE BASED ON THE TYPE IIB CLASSIFICATION OF THE ORIGINAL BUILDING CONSTRUCTION, FOR ANY WOOD MATERIALS INSTALLED, FIRE -
RETARDANT TREATED WOOD IS ALLOWABLE (VCC 603.1) AND IS REQUIRED
6. SPRINKLER REQUIREMENTS (VCC CHAPTER 9)
-ANY NEW WORK SHALL BE PERFORMED IN COMPLIANCE WITH NPFA 13 (2016)
7. PORTABLE FIRE EXTINGUISHERS (VCC SECTION 906): ONE 5 LB CLASS ABC FIRE EXTINGUISHER PROVIDED
- ORDINARY (MODERATE) HAZARD OCCUPANCY
- MINIMUM RATED SINGLE EXTINGUISHER: TYPE 2A:10B:C
- MAXIMUM FLOOR AREA PER UNIT OF A:1,500 SF (2A PROVIDED = 3,000 SF)
- MAXIMUM FLOOR AREA FOR EXTINGUISHER:11,250 SF
- MAMUM DISTANCE OF TRAVEL TO EXTINGUISHER: 75 FEET
- UNDER 40 LBS REQUIRED TO BE INSTALLED SO THAT THE TOP OF THE EXTINGUISHER IF NOT MORE THAN 5' AFF (VCC 906.9.1)
- PORTABLE EXTINGUISHERS MUST BE PROVIDED IN ACONSPICUOUS LOCATION, UNOBSTRUCTED AND UNOBSCURED, AND IN AN UNLOCKED CABINET (VCC 906.5, 906.6 AND 906.8)
8. ENERGY CODE COMPLIANCE
- EXISTING BUILDING EXTERIOR ENVELOPE (VECC C501.2): NO REMOVAL, ALTERATION OF THE EXSITNG EXTERIOR CONSTRUCTION IS REQUIRED AND NONE WILL BE PERFORMED THEREFORE COMPLIANCE WITH THE CURRENT
ENERGY CODE IS NOT APPLICABLE AS THE EXISTING BUILDING WAS CONSTRUCTED TO COMPLY WITH THE 2012 VECC
PLUMBING FIXTURES (VCC CHAPTER 29)
TYPE
EXISTING REQUIRED
EXISTING PROVIDED
NEW WORK REQUIRED
NEW WORK PROVIDED
WATER CLOSET (WC)
1 PER 75 OCC 1 M+W
2 UNISEX
1 UNISEX
2 UNISEX TO REMAIN
LAVATORIES (SINKS)
1 PER 200 OCC 1 M+W
2 UNISEX
1 UNISEX
2 UNISEX TO REMAIN
SERVICE SINK
1 SERVICE SINK
1
1
1 EXISTING TO REMAIN
DRINKING FOUNTAIN
1 PER 500 OCC
NONE
1
1 ADA WITH BOTTLE FILL
FIXTURE CALCULATIONS FOR NEW WORK:
OCCUPANCY
# OCCUPANTS
WATERCLOSETS
#REQ
SINKS
# REQ
DRINKING FOUNTAIN
# REQ
MERCANTILE (M)
19 TOTAL
1 PER 500 OCC
0.04
1 PER 750 OCC
0.03
1 PER 1,000 OCC
0.01
ASSEMBLY (A-3)
31 TOTAL
1 PER 75 OCC
0.41
1 PER 200 OCC
0.16
1 PER 500 OCC
0.06
ACCESSORY
5 TOTAL
1 PER 100 OCC
0.05
1 PER 100 OCC
0.05
1 PER 1,000 OCC
0.01
TOTALS
WATERCLOSETS
0.50
SINKS
0.24
DRINKING FOUNTAIN
0.08
OCCUPANT LOAD FACTORS (VCC TABLE 1004.5)
FUNCTION
AREA
ABBREVIATION
MERCANTILE
60GSF/OCCUPANT
M
STORAGE/STOCK
300GSFIOCCUPANT
STO
MECH/ACCESSORY
300GSFIOCCUPANT
ACC
ASSEMBLY (A-3) UNCONCENTRATED TABLES AND CHAIRS
15 NSF 1 OCCUPANT
A-3
FIRE RESISTANCE RATINGS MATRIX - BUILDING ELEMENTS CONSTRUCTION TYPE IIB (NON-COMBUSTIBLE)
VCC 2018
BUILDING ELEMENT
RATING READ (HOURS)
PROVIDED
TABLE 601
PRIMARY STRUCTURE
0
0
TABLE 601
BEARING WALL - EXTERIOR
0
0
TABLE 601
BEARING WALL - INTERIOR
0
0
TABLE 601
NON -BEARING WALLS - EXT
0
0
TABLE 601
NON -BEARING WALLS - INT
0
0
TABLE 601
FLOOR CONSTRUCTION
0
0
TABLE 601
ROOF CONSTRUCTION
0
0
s1a1 FLOOR PLAN - LIFE SAFETY
0 2' 4' 8'
1/4" = 1.4.
11
DESIGN
DEVELOP
ARCHITECTURE - VISUALIZATION - ENTITLEMENT
www.designdevelopllc.com
ARCHITECT
Design Develop, LLC
418 East Main Street
Charlottesville, VA 22902
434.443.4045
Contact: Khanh Uong, RA
Email: kuong@designdevelopllc.com
No. Description Date
BRICKS AND
MINIFIGS
RENOVATION
100%
CONSTRUCTION
DOCUMENTS
2050 BOND STREET, SUITE 110,
CHARLOTTESVILLE, VA 22901
LIFE SAFETY AND
CODE ANALYSIS
Project number 2022-Bricks and Figs
Date 11/08/2022
Drawn by MM
Checked by BP
LS-101
Scale 1/4" = 1'-0"
C
7
A
RUN EXISTING PLUMBING TO NEW
WATER FOUNTAIN
EXISTING CONCRETE FLOOR
FINISH TO REMAIN
ALL PLUMBING FIXTURES AND WASHROOM
ACCESSORIES ARE EXISTING TO REMAIN
INSTALLED PER [CC Al17.120D9
EXISTING HOLLOW METAL DOOR
AND FRAME TO REMAIN
EXISTING RESTROOM
THRESHOLD TO REMAIN
SERVICE SINK EXISTING TO REMAIN
ALL PLUMBING FIXTURES AND WASHROOM
ACCESSORIES ARE EXISTING TO REMAIN
INSTALLED PER ICC A117.12009 -
EXISTING RESTROOM
THRESHOLD TO REMAIN
EXISTING HOLLOW METAL DOOR
AND FRAME TO REMAIN
EXISTING SINK AND SURROUNDING
MILLWORK TO BE REMOVED
EXISTING THREE -COMPARTMENT
SINK TO REMAIN
EXISTING HAND SINK TO REMAIN
EXISTING BAR MILLWORK TO BE
REMOVED
EXISTING CASED OPENING WITH SALOON
STYLE DOUBLE-ACTING SWING PANELS
TO BE REMOVED
Al FLOOR PLAN - DEMOLITION
4D-10
0 24' 8'
3/16" = 1'-O"
DEMOLITION GENERAL SHEET NOTES
EXSITNG HOLLOW METAL DOOR
AND FRAME TO REMAIN
EXSITNG STOREFRONT TO REMAIN
E108
BUILDING --_--:.:----------------------------------------
_
SPRINKLER_________________________________________------
EXSITNG HOLLOW METAL DOOR
�.�
ROOM ---------------------------------- - -- - - - - - - - -
- AND FRAME TO REMAIN
NOT IN SCOPE -------------------------------------------
------------------------------------------ --
\
----------------------------------------- ---
---_--------_----------------_------_-_-_-_-_--------_-_
EXISTING OVERHEAD COILING
------------------------ - - - - ------------
DOOR TO REMAIN
E�6)
-------------------------------------------
---------------------------------- -----
U---------------- -- -- ---------------------------------------- -- --- ------------------
� --- - - - -- - - ------------------- --------- --- - - ----------- --------------
EXSITNG STOREFRONT TO REMAIN
--------------------------------- ----------
-
`E105j
-_----- -------------------------------
EXISTING ACOUSTIC TILE CEILING
TO REMAIN TYPICAL
EXISTING EMERGENCY LIGHT
FIXTURES TO REMAIN TYPICAL
EXISTING EXIT SIGNAGE TO
REMAIN TYPICAL
DESIGN
DEVELOP
ARCHITECTURE • VISUALIZATION • ENTITLEMENT
www.designdeveloplIc.com
ARCHITECT
Design Develop, LLC
418 East Main Street
Charlottesville, VA 22902
434.443.4045
Contact: Khanh Uong, RA
Email: kuong@designdevelopllc.com
-_IE-vc--------- --c------c�-----c------
_ - _ -
- - ------c----
- - -
- --- - --
u
- - - -_-
- - -_-
- - -_-
_-_-_-_-_ - --'L-------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------
EXISTING WALL MOUNTED LIGHT
FIXTURES TO REMAIN TYPICAL
EXISTING EXIT SIGNAGE TO
REMAIN TYPICAL
- - - - - - - ----------
-----------------------------
--------- --------------------------- ---------
------------------ -----------------------
EXISTING SPRINKLER HEADS AND
__ __
_ _ _ _
E101
SYSTEM TO REMAIN
__
____________________________
--________________________________________________
REMOVE ALL EXISTING FLOOR
FINISHES TOCONCRETE SLAB
=T/PICALTHROUGHOUT_-=
-
-_- -- - -
=
__
-- =
- -
EXSrrNG STOREFRONT DOUBLE ENTRY
No.
Description
Date
- - - -
- -_
(�
Q
(�
Q
(�
o
_ - _ - � _ _ _ _
i
HEADS TO REMAIN TYPICAL
•
O
O
•
O
O
•
O�
0
•
FIXTURES
�.�---------_-----------------------c--c--c--------------c--------------------c------c------------c------------------
AIN
MAINTYPICAL
OREM
- -
--- _ _ --- --
--- _- -_- _ -
_-_- -_ -
EXSITNG STOREFRONT TO REMAIN
----
-
----------------------cc----------cc----c------c------------c----cc----cc--cc----c--------
EXISTING GYPSUM BOARD AND
METAL FRAMED FIT AND
FPREP
_- - - -
_- - - - - -_
- - -_
TO REMAIN FOR PIA NT
C - -
- - - -
--
- - --
-
--
•-
-- i-----� ----
-
---
--------------
- ----------- - -
- - --
-
_ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _� _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _
__ __ _ - .___i
�.----
1 INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING
CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING
DRAWINGS OR GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE
ACTUAL EXISTING CONDITIONS IN DETAIL OR DIMENSION. THE
CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE ACTUAL
EXISTING CONDITIONS PRIOR TO FABRICATION OR PERFORMANCE OF
ANY WORK. SHOULD CONDITIONS BEDISCOVERED THAT PREVENT
EXECUTION OF THE WORK AS INDICATED, THE CONTRACTOR SHALL
IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING AND AWAIT
DIRECTION BEFORE PROCEEDING WITH THE WORK.
2 SEE STRUCTURAL AND CIVIL DOCUMENTS FOR ADDITIONAL DEMOLITION
REQUIREMENTS. DEMOLITION DRAWINGS ARE NOT THE LIMIT OF
CONTRACT FOR DEMOLITION WORK.
3 UNLESS NOTED OTHERWISE, EXISTING FINISH SUBSTRATES TO REMAIN
ARE TO BE PATCHED AND PREPARED FOR INDICATED FINISH.
4 PROTECT FROM WEATHER ANY OPENINGS TO THE INTERIOR, EITHER
EXISTING OR CREATED DURING DEMOLITION.
6 CONTRACTOR TO VERIFY SIZE OF NEW SHAFT OPENINGS WITH
MECHANICAL REQUIREMENTS. COORDINATE LOCATION OF NEW
OPENINGS WITH ARCHTIECTURAL FLOOR PLANS. CONTRACTOR TO LAY
OUT WALLS PRIOR TO CUTTING NEW OPENINGS IN FLOOR TO
COORDINATE ALL REQUIRED DIMENSIONAL REQUIREMENTS.
6 OPENING DIMENSION ON DRAWINGS REFERS TO FINISH DIMENSION,
UNO.
EXISTING EXISTING DOOR REMOVED TO CREATE
A SINGLE LARGER STORAGE ROOM
CASED OPENING TO REMAIN
EXISTING ELECTRICAL PANEL TO
REMAIN - TENANT SHALL MAINTAIN
ACCESS TO PANELS
EXISTING HVAC SYSTEM AND
REGISTERS TO REMAIN TYPICAL
A3 REFLECTED CEILING PLAN - DEMOLITION
D-10
0 2' 4' 8'
3/16" = 1'-0"
7 REMOVE ALL UNUSED PIPING, DUCTS, ETC IF EXPOSED OR UNCOVERED
DURING DEMOLITION. COORDINATE WITH MEP SUB. UNLESS NOTED
OTHERWISE, PATCH ALL VOIDS LEFT BY REMOVAL OF PIPES, DUCTS,
ETC AND PREPARE FOR INDICATED FINISH.
8 PROTECT ALL EXISTING WORK TO REMAIN FROM DAMAGE DURING
DEMOLITION AND CONSTRUCTION.
EXISTING LIGHT FIXTURES
TO REMAIN TYPICAL
DEMOLITION LEGEND
® EXISTING WALL, PARTITION, OR
ARCHITECTURAL ELEMENT TO REMAIN
- - EXISTING WALL, PARTITION, OR
ARCHITECTURAL ELEMENT TO BE
r- REMOVED
\ DOOR AND FRAME TO BE REMOVED
_1 EXISTING FLOOR TO BE REMOVED
BRICKS AND
MINIFIGS
RENOVATION
100%
CONSTRUCTION
DOCUMENTS
2050 BOND STREET, SUITE 110,
CHARLOTTESVILLE, VA 22901
DEMOLITION PLANS
Project number 2022-Bricks and Figs
Date 11/08/2022
Drawn by MM
Checked by BP
AD-101
Scale As indicated
u
2
3
4
5
7
rsmoan
�m
C
7
A
---------------------------
MOO
it'
#1: EXISTING EGRESS DOOR
#2: EXISTING EXIT DOOR (NOT SHOWN IN ORIGINAL DRAWINGS BUT
THERE)
#3:NEW �/4 TALL WALL (NOT SURE WHAT 3/4 IS BUT ASSUME 8"
TALLER THAN AN INTERIOR DOOR
#4: OVERHEAD GARAGE DOOR TO REMAIN.
#5: FRONT DOOR EXIT
#6 INTERIOR DOORS TO BACKROOM
#7 EXISTING SINK TO BE REMOVED AND WATER COOLER TO BE ADDED
HERE (CODE COMPLIANCE UNLESS THERE IS AN EXEMPTION FOR NOT
HAVING IT)
#8: MOP SINK
#9 VIEW TO BACK PANTRY
#10 GENERAL VIEW OF RETAIL SPACE, DIVIDING WALL
#11: VIEW TO BATHROOM
#12: VIEW TO FACE OF EGRESS DOOR (OTHER SIDE OF #2)
#13: VIEW OF SINK IN PANTRY.
DESIGN
DEVELOP
ARCHITECTURE • VISUALIZATION • ENTITLEMENT
www.designdevelopllc.com
ARCHITECT
Design Develop, LLC
418 East Main Street
Charlottesville, VA 22902
434.443.4045
Contact: Khanh Uong, RA
Email: kuong@designdevelopllc.com
No. Description Date
BRICKS AND
MINIFIGS
RENOVATION
100%
CONSTRUCTION
DOCUMENTS
2050 BOND STREET, SUITE 110,
CHARLOTTESVILLE, VA 22901
EXISTING
CONDITIONS
Project number 2022-Bricks and Figs
Date 11/08/2022
Drawn by MM
Checked by BP
AD-102
Scale
u
2
3
4
5
PITTCON SWC-358-8 WALL CAP TRIM WHITE
DOOR
SCHEDULE
AND
HARDWARE
SET
REQUIREMENTS
9'-0" TOP OF WALL
314" FIRE RETARDANT PLYWOOD
EGRESS
ABILITY
IMPAIRED
LOCKSET
MISCELLANEOUS
HARDWARE
KEY
DESIGN
iEa
/
REQUIREMENTS
REQUIREMENTS
(TYPE IA=6-0")
O EXISTING TO REMAIN
DEVELOP
►1EAD
O
NEW WORK
PROVIDE ACOUSTIC SEALANT AT ALL
PENETRATIONS AND OPENINGS
�
5
z
y
z
o
ti
z
w
ARCHITECTURE VISUALIZATION ENTITLEMENT
U
OJ
w
o
3
O
W
H
J
K
U
H
O
W
J
35/8" METAL FRAMING 20GA
DOOR
FRAME
w
-
W
H
V
p
Q
H
F
a
i
¢
W
O
W
a
r
O
s
y
m
s
ti
w
K
cw
w
O
os
p
(TYPEtA=2"METAL FRAMING
DOOR#
ROOM NAME
MATL
SIZE
MATL
RATING
Q
o
J
3
m
w¢
ap
a
g
,"—�
o
o
F
w
i
g
E
o
w
COMMENTS
�vww.designdeveloplc.com
d
2
Q
w
O
J
1-
Q
Q
Y
LL
2
6.
U
O
4l
W
LL
2
p
Q
(h
(A
2
LL
31/2" ROCKWOOL COMFORTBATT MINERAL WOOL INSUALTION
(TYPE tA=DELETED)
E101
MAIN ENTRANCE
ALUM/GLS
6-0" x 7'-0"
ALUM
O
O
O
O
O
O
O
O
3
3
EXISTING SWING DOOR TO REMAIN
E105
UNISEX
HM
3'-0" x T-0"
HM
O
O
O
O
O
O
3
3
O
EXISTING SWING DOOR TO REMAIN
CO GYPSUM BOARD WITH EGGSHELL PAINT FINISH
- COLOR TO BE SELECTED BY TENANT
z
(TYPE 1A = ONE SIDE DELETED)
Lu
ARCHITECT
Design Develop, LLC
E106
UNISEX
HM
3'-0" x 7'-0"
HM
O
O
O
O
O
O
3
3
O
EXISTING SWING DOOR TO REMAIN
or
o
418 East
Charlottesville,'VA Street2902
E107
PARTY ROOM
HM
T-0" x T-0"
HM
O
O
O
O
3
3
O
EXISTING SWING DOOR TO REMAIN
PLAN
CD
Z
IF—
434.443.4045
Contact: Khanh Uong, RA
E107A
PARTY ROOM
STUGLS
20'-0" x 10'-0"
STL
EXISTING OVERHEAD COILING DOOR TO REMAIN
BASE
1/4" MIN ACOUSTIC SEALANT AND BACKER ROD AT
x
w
Email: kuong@designdevelopllc.com
E107B
PARTY ROOM
HM
3'-0" x T-0"
HM
O
O
O
O
3
3
O
EXISTING SWING DOOR TO REMAIN
BASE MATERIAL TO BE SELECTED BY
ENTIRE PERIMETER
E106
REAR EXIT
HM
3'-0" x TO"
HM
O
O
O
O
O
1
O
O
3
3
1
EXISTING SWING DOOR TO REMAIN
TENANT
SCHEDULED FINISH FLOOR
104
EMPLOYEE AREA
HM
3'-0" x T-0"
HM
O
O
O
O
O
3
3
O
NEW LOCKABLE STORAGE SWING DOOR
w
SUBFLOOR
METAL FRAMING CHANNEL 20GA
z
C1 NEW PARTITION
A-101
1" = 1.4.
CARPET TO CONCRETE ADA
REDUCER BY GENOTEK OR SIMILAR
COORDINATE FINAL PRODUCT WITH
THICKNESS OF INSTALLED
C
MATERIALS PROVIDE STAINLESS
STEEL MATERIAL
5 LB TYPE 2AA0B:C FIRE EXTINGUISHER
IN SURFACE -MOUNTED CABINET
PARTY ROOM
JLINDUSTRIES AMBASSADOR SERIES
STEEL FINISH WHITE TO BE PAINTED TO
107
MATCH WALLS IN FIELD
UNISEX
ALL PLUMBING F0(TURES AND WASHROOM
MOUNT TOP OF CABINET AT 5'-V AFF
ACCESSORIES ARE EXISTING TO REMAIN
x 48" CLEAR FLOOR AREA FOR ADA
1 O6
INSTALLED PER ICC Al17.120D9
.---'
COMPLIANCE AT DRINKING FOUNTAIN
CO
ELKAYLMABF8WSLK
ADA WATER COOLER FILTERED,
E108
..--
_ -
I
—
-
1
REFRIGERATED INCLUDING BOTTLE
FILL STATION ALSO PROVIDE
IN -WALL CARRIERMLP-100
BUILDING
UNISE�C- SPRINKLER
EO 0
LJ
LLLLJJJJ
_ —
FURNITURE SHOWN A ILLUSTRATIVE
OF THE PLANNED USAGE OF SPACE
FINALL TYPE AND ARRANGEMENT TO
10' - 0" AFF
SPRIINKILER
_
-
L'
PAINT ALL OPEN SUSPENDED
MOUNTSPOUTAT36"AFF MAXIMUM
ROOM
ROOM
'�
GRID CEILING METAL TEES
EXTEND PLUMBING FROM UNISEX 105
1O6
NOT IN SCOPE
_
BE DETERMINED BY TENANT
a
NOT IN SCOPE
@
�/( ,��
Ob
WITH ENAMEL PAINT COLOR
WET WALL TO WATER COOLER
_
-
\��
TO BE SELECTED BY TENANT
NEW CARPET TILE TO BE
AR ROOM
TARKETT SSR-XX-B ADA TRANSITION
SELECTED BY TENANT
OR SIMILAR COORDINATE FINAL
_�'
-
0
107 0 0
14' - 0" AFF
PRODUCT WITH THICKNESS OF
INSTALLED MATERIALS PROVIDE--'
_
E106 0
TARKETT CTA-XX-L ADA TRANSITION
COLOR 71 STORM CLOUD OR TO BE
-
OR SIMILAR COORDINATE FINAL
O
O O O
SELECTED BY TENANT —
1 -- -
rh
P OF
\
INSTALLED MATERIALS PROVIDE
INSTALLED MATERITH IALS PRO
No.
Description
Date
SERVICE SINK EXISTING TO REMAIN
UNISEX
_
COLOR 71 STORM CLOUD OR TO BE
-
15)
SELECTED BYTENANT
10'-0"AFF
UNI EX
ALL PLUMBING FUTURES AND WASHROOM
105
e
n !
ACCESSORIES ARE EXISTING TO REMAIN
10
INSTALLED PER [CC At 17.12009
TARKETT SSR-XX-B ADA TRANSITION
OR SIMILAR COORDINATE FINAL
PRODUCT WITH THICKNESS OF
INSTALLED MATERIALS PROVIDE
B
COLOR 71 STORM CLOUD OR TO BE
SELECTED BY TENANT
e O
O
•
O
O e O O o
E101
PAINT ALL OPEN SUSPENDED
NEW LVT FLOORING TO BE SELECTED
GRID CEILING METAL TEES WITH
BY TENANT (TYPICAL)
ENAMEL PAINT COLOR TO BE
RET
L S AC
SELECTED BY TENANT
101
T - 7" VERIFY IN FIELD
- PAINT ALL INTERIOR WALL SURFACES THEIR
LVT TO CONCRETE ADA REDUCER
BY GENOTEK OR SIMILAR
�b
�)
�_�
, _ _�
O i
0 '� )
14' - 0" AFF
- -EXISTING
BRICK WITH SATIN FINISH
COLOR TO BE
FINALSTALL DUCT WITH
�/
/
NEW HOLLOW METAL DOOR AND
1
DETERMINED BY TENANT
-
THICKNESS OF INSTALLED
THICKNCOORDESS O
n
FRAME PROVIDE ACOUSTICAL
'-
-
MATERIALS PROVIDE STAINLESS
STEEL MATERIAL
SEALANT AT ENTIRE PERIMETER
!
PAINT DOOR AND FRAME WITH SEMI-
-
NEW LED EXIT SIGN TO MATCH
GLOSSISATIN PAINT TO MATCH WALLS �,
EXISTING MOUNT ON WALL
CENTERED ABOVE DOOR
o �0
-
� 0
o�0)
_-
o
EMPLOYEE AREA
PAINT ALL GYPSUM BOARD
BRICKS AND
1 O4
v-
9
SURFACES WITH EGGSHELL
PAINT COLOR TO BE SELECTED
BY TENANT
- --
MINIFIGS
-it 4s
LL
DASHED LINE INDICATES
EMPLOYEE AREA
R E N OVAT I O N
CENTER NEW PARTITION ON CORNER OFL
EXISTING WALL PROVIDE DOUBLE STUDS
�I
APPROXIMATE LOCATION AND
CONFIGURATION OF STORAGE
10' - 0" AFF
104
ON BOTH SIDES AND LINTEL ABOVE
— — - — 'oo 0 0
0
SHELVING
0
100/0
DOOR AS PART OF METAL FRAMING -- -
e
FURNITURE SHOWN IS ILLUSTRATIVE
i
CONSTRUCTION
OF THE PLANNED USAGE OF SPACE
i
FINALL TYPE AND ARRANGEMENT TO
-
DOCUMENTS
BE DETERMINED BY TENANT
2050 BOND STREET, SUITE 110,
-�
EXISTING ELECTRICAL PANEL TO
10' - 0" AFF STORAGE
CHARLOTTESVILLE, VA 22901
A
REMAIN -TENANT SHALL MAINTAIN
1
ACCESS TO PANELS
O2
FLOOR PLANS
Project number 2022-Bricks and Figs
Date 11/08/2022
Drawn by MM
as
Checked by BP
Al FLOOR PLAN
A3
REFLECTED CEILINGPLAN
A-101
A-101
�
A-101
scale As indicated
N
0 2 4 8
o z 4' $
1
2
3
4
5