HomeMy WebLinkAboutSDP202200035 Other 2022-12-29YV woeasu..o..+ m. �w r« 'f LOT` _ DRAWING INDEX Sheet 1 Site Plan 2 General Notes/ Design Parameters 3-4 Details 5-6 Wall A - Sta. 0 to Sta. 237 7-8 Wall B - Sta. 0 to Sta. 249 9 - 10 Wall C - Sta. 0 to Sta. 187.5 11 Wall D - Sta. 0 to Sta. 111 12 Wall E - Sta. 0 to Sta. 66 WALLA' ✓ Anchor Diamond Pro Segmental Retaining Walls Pleasant Green - Phase IIB/III Albemarle County, Virginia Site Plan Adapted From The Grading & Drainage Plan, Sheet No. 12 and Sheet No. 13, Dated May 14, 2021, Prepared By Collins Engineering. Site Plan For Illustrative Purpose. Approx. Scale: V = 100 FT SITE PLAN ���iH AFL o� u MICHAEL R. b Uc. No. 021245 �o� /Z�2zrZZ WALL E-------- 0 LOT LOT Scale: 1" = 100 FT 050 100 Circeo 5956 Buckland Mill Road Geotechnical Roanoke, Virginia 24019 _ Engineering, P.C. 9 FA I Phone: (540) 366-2379 Project No. I RW-2897 NOTES: 1.0 STRIP VEGETATIVE AND ORGANIC SOIL FROM THE WALL AND GEOGRID ALIGNMENT. 2.0 BENCH CUT ALL EXCAVATED SLOPES. 3.0 DO NOT EXCAVATE BEYOND EXCAVATION LINES SHOWN ON PLAN UNLESS DIRECTED BY THE GEOTECHNICAL ENGINEER TO REMOVE UNSUITABLE SOIL. 4.0 CONTRACTOR SHALL ENSURE TEMPORARY EXCAVATIONS ARE STABLE AND PROVIDE EXCAVATION SUPPORT IF NEEDED. 5.0 GEOTECHNICAL ENGINEER SHALL VERIFY FOUNDATION SOILS AS BEING COMPETENT PER THE DESIGN PARAMETERS. 6.0 LEVELING PAD SHALL CONSIST OF COMPACTED SAND, GRAVEL, OR COMBINATION AND SHALL BE A MINIMUM 6-INCH THICK LAYER WITH A MINIMUM WIDTH OF 24 INCHES. 7.0 A 4-INCH-DIAMETER SLOTTED DRAINAGE PIPE SHALL BE INSTALLED BEHIND THE WALL AND CONNECT TO WEEPHOLES INSTALLED AT THE BASE OF THE WALL (40 FEET ON CENTER) AND EXTEND BEYOND THE FINAL GRADE TO DAYLIGHT (SEE DRAIN DETAIL). 8.0 DRAINAGE AGGREGATE AND UNIT (CORE) FILL SHALL CONSIST OF CLEAN ANGULAR GRAVEL (VDOT NO. 57 STONE), MEETING THE FOLLOWING GRADATION AS DETERMINED IN ACCORDANCE WITH ASTM D-422. SIEVE SIZE PERCENTAGEPA55ING 1-112 INCH 100 1 INCH 95-100 1/2 INCH 25 - 60 NO.4 0-10 NO. 8 0-5 9.0 GEOGRIDS SHALL BE LAID HORIZONTALLY ON COMPACTED BACKFILL FOR THE REQUIRED GEOGRID LENGTH (GL) IN THE TENSILE STRENGTH DIRECTION (PERPENDICULAR TO WALL FACE) NOTED ON THE WALL PROFILE. THE GEOGRID SHALL BE PLACED WITHIN ONE INCH OF THE FRONT FACE OF THE UNIT BELOW AND EXTEND HORIZONTALLY OVER COMPACTED FILL. 10.0 ANCHOR DIAMOND PRO UNITS MOLDED DIMENSIONS SHALL BE 8 INCHES HIGH BY 18 INCHES LONG BY 12 INCHES DEEP AND SHALL NOT DIFFER MORE THAN + 1/8 INCH IN ANY DIMENSION. 11.0 A 1-INCH SETBACK PER UNIT (REAR LIP) SHALL BE MAINTAINED FOR PROPER BATTER (I.E. 7 DEGREE CANT FROM VERTICAL). 12.0 GEOGRIDS SHALL BE PLACED WITHIN 1 INCH OF THE FRONT FACE OF THE UNITS AND GEOGRID5 PULLED TIGHT (AFTER PLACEMENT OF THE NEXT COURSE OF BLOCK UNITS) TO REMOVE SLACK AND TO INTEGRATE GEOGRIDS AND UNITS. 13.0 FIELD ADJUSTMENTS OF BLOCK ALIGNMENT MAY BE MADE ON NON -REINFORCEMENT LAYERS WITH THE USE OF SHIMS OR ASPHALT SHINGLES TO RAISE ONE COURSE OF BLOCK BY A MAXIMUM OF 1/4 INCH VERTICAL HEIGHT. 14.0 REINFORCED FILL SHALL CONSIST OF GRANULAR SOIL FILL WITH U5C5 SOIL TYPES GP, GW, GM, GC, 5W, SP, SM OR 5C WITH A MINIMUM ANGLE OF INTERNAL FRICTION, OF 28 DEGREES AS OUTLINED IN DESIGN PARAMETERS - NOTE 5. LOW PLASTICITY CLAYEY SAND (SC), SILT OR CLAY (ML-CL) CAN BE USED SUBJECT TO APPROVAL BY THE GEOTECHNICAL ENGINEER. MAXIMUM PARTICLE SHALL BE LIMITED TO 4INCHES IN DIAMETER. THE FINE FRACTION (MINUS NO. 40 SIEVE) SHALL HAVE A MAXIMUM LIQUID LIMIT (LL) OF 40 AND A MAXIMUM PLASTICITY INDEX (PI) OF 20. THE BACKFILL SHALL BE FREE OF DEBRIS AND ORGANIC MATTER. HIGHLY EXPANSIVE SOILS (MH-CH) SHALL NOT BE USED IN THE REINFORCED FILL ZONE. 15.0 REINFORCED FILL SHALL BE PLACED IN 8-INCH LIFTS AND COMPACTED TO A MINIMUM OF 95% OF MAXIMUM STANDARD PROCTOR DENSITY (A5TM D-698) AND WITHIN + 3 PERCENTAGE POINTS OF OPTIMUM MOISTURE CONTENT. COMPACTION TESTS SHALL BE PERFORMED AS THE WALL I5 INSTALLED. COMPACTION WITHIN 3 FEET OF THE WALL SHALL BE LIMITED TO HAND -OPERATED EQUIPMENT. DESIGN PARAMETERS: 1 BUILDING CODES: 2018 VIRGINIA UNIFORM STATEWIDE BUILDING CODE (USBC) AND 2018 INTERNATIONAL BUILDING CODE (IBC). 2 THE WALL PROFILES ARE BASED ON THE GRADING & DRAINAGE PLAN, SHEET NO. 12 AND SHEET NO. 13, DATED MAY 14, 2021, PREPARED BY COLLINS ENGINEERING. 3 WALL DETAILS SHOWN ON THIS PLAN ARE FOR ANCHOR DIAMOND PRO SEGMENTAL RETAINING WALL (SRW) UNITS MEETING THE NATIONAL CONCRETE MASONRY ASSOCIATION (NCMA) CRITERIA FOR SRW WALL SYSTEMS. 4 ENGINEERING ANALYSIS BASED ON USE OF STRATAGRID 5GU60 AND 5GU80 GEOGRID5. OTHER COMPATIBLE GEOGRIDS MAY BE SUBSTITUTED WITH THE APPROVAL OF THE WALL DESIGN ENGINEER. 5 THE DESIGN OF THE SEGMENTAL RETAINING WALL (SRW) ASSUMES THE FOLLOWING PARAMETERS: Ym, Moist FRICTION SOIL SOIL UNIT WEIGHT ANGLE COHESION CONDITIONS Type (PCF) 0, (DEG) (PSF) REINFORCED FILL Granular or Low Plasticity Soil 120 28 0 RETAINED SOIL On -Site Soil 120 28 0 FOUNDATION SOIL On -Site Soil 120 28 100 16.0 A VIBRATORY PLATE TAMPER SHALL BE USED TO DEN5IFY NO. 57 STONE. COMPACTION TESTS CAN BE WAIVED WHERE NO. 57 STONE I5 USED AS REINFORCED FILL. 17.0 CONTRACTOR SHALL SLOPE SITE GRADES TO DIRECT SURFACE RUNOFF AWAY FROM WALL AT END OF EACH DAY TO AVOID WATER DAMAGING THE WALL WHILE UNDER CONSTRUCTION. 18.0 ANY SURFACE DRAINAGE FEATURES, FINISH GRADING, PAVEMENT, OR TURF SHALL BE INSTALLED IMMEDIATELY AFTER THE WALL I5 COMPLETED. 19.0 IF SITE AND SOIL CONDITIONS, WALL GEOMETRY, OR WALL LOADING ARE DIFFERENT THAN THE DRAWINGS AND THE DESIGN PARAMETERS, THE CONTRACTOR MUST CONTACT THE WALL DESIGN ENGINEER PRIOR TO PROCEEDING WITH THE CONSTRUCTION OF THE WALL. 20.0 DETAIL FOR HANDRAIL POSTS AT THE TOP OF THE WALL IS PROVIDED FOR PLACEMENT OF P05T5 BEHIND THE WALL. V Setba6 7pen Cells Filled With Stone) V Rear Lip UNIT CONNECTION DETAIL (Not to Scale) 6 SOIL STRENGTH PARAMETERS ARE BASED ON USE OF GRANULAR OR LOW PLASTICITY SOIL IN THE REINFORCED FILL ZONE. ALL SOIL FILL SHALL BE PLACED IN MAXIMUM 8-INCH LIFTS AND EACH LIFT IS COMPACTED TO A MINIMUM OF 95% OF MAX. STANDARD PROCTOR DENSITY, AND WITHIN + 3 PERCENTAGE POINTS OF OPTIMUM MOISTURE CONTENT, USING PORTABLE COMPACTION EQUIPMENT. DO NOT USE HIGH PLASTICITY CLAY (CH-MH), ROOTS OR TOPSOIL IN REINFO ZONE. ANY SOFT, SATURATED SOIL ENCOUNTERED IN 5UBGRADE SHALL BE UNDERCUT AND REPLACED WITH CRUSHED STONE TO STABILIZE THE FOUNDATION 5UB6RADE OR AS DIRECTED BY THE GEOTECHNICAL ENGINEER. WALL A - MAX. WALL HEIGHT = 7.33 FEET (INCLUDING EMBEDMENT) WALL B - MAX. WALL HEIGHT = 6.67 FEET (INCLUDING EMBEDMENT) WALL C - MAX. WALL HEIGHT = 6.67 FEET (INCLUDING EMBEDMENT) WALL D - MAX. WALL HEIGHT = 6.67 FEET (INCLUDING EMBEDMENT) WALL E - MAX. WALL HEIGHT = 5.33 FEET (INCLUDING EMBEDMENT) FRONT SLOPE = LEVEL TO MAX 3H:IV BACKSLOPE BEHIND THE WALL = LEVEL TO MAX 3H:IV EQUIVALENT BUILDING SURCHARGE AT TOP OF WALL = 350 PSF MIN FACTOR OF SAFETY (SLIDING) = 1.5 MIN FACTOR OF SAFETY (OVERTURNING) = 2.0 MIN FACTOR OF SAFETY (BEARING CAPACITY) = 2.0 q = DESIGN SOIL BEARING PRESSURE = 750 PSF TO 2,250 PSF MICHAEL Lic. No. 021245 % /Zl�22 AL AiU'11 wi..rl 111u.. LlW Albemarle County, Virqinia Circeo Geotechnical Engineering, P.C. Scale: N/A Date: 12/22/22 Revision: --- 5956 Buckland Mill Road Roanoke, Virginia 24019 Phone:(540) 366-2379 Fax: (540) 904-6200 Project No. I RW-2897 Alternate Geogrid Placement on Subsequent Geogrid Elevations to Eliminate Gaps \ Overlap Geogrids and Place 3" Soil Fill Between Overlapping Geogrids for Proper Anchorage SRW Units CONVEX CURVE DETAIL (Not to Scale) D---- —A G.....1.. ,.a o..aa..... -4 \AI-11 rvun o 1 ripuK R cY Yviue Crusher Run or Similar Foundation Soil BASE STEPPING DETAIL (Not to Scale) 42" Tall Safety Handrail or Fence Non -Woven Filter Fabric w/ Sleeve -It SDI Fence -Post Anchoring System Mirafi 140N or Equivalent Geogrid Reinforcement (Typical) Cop Unit Refer to Wall Profile for Geogrid Type, Secure t Geogrid Length (GL) and Location o Top Unit w/ Concrete Adhesive Anchor Diamond Pro Units Drainage Aggregate`'""'"`' Min 12" Thick VDOT No. 57 Stone Weephole w/Wall Drain Pro — — — —� 24" Vertical Spacing (Typ.) Daylight Pipe Through Wall Retained Soil 40' OC Spacing (TypJ — — Reinforced Fill Dia. Drain Pipe Granular or Low Plasticity Soil Compacted Backfill T. (See Drain Detail) Compact To Min 95 % Standard Stone Leveling Pod GL Proctor Density Crushed Stone or and 6" Min Thick x 24" Wide See Wall Profile TYPICAL RETAINING WALL CROSS SECTION (Not to Scale) j f 12-1/2" i Ell 0 1- l 15trai ht 1 9 Rear Lip Split Face 18 w 1" Setback 8-1/2" 8" { 8" / y1 1 I ANCHOR DIAMOND PRO UNIT (Not to Scale) ,x`:', API TH 01;'i s MICHAEL R. I Uc, No. 021245 AL Circeo Geotechnical Engineering, P.C. 5956 Buckland Mill Road Roanoke, Virginia 24019 Phone:(540) 366-2379 Project No. I RW-2897 42" Tall Pedestrian Guard w/ Sleeve -It Fence -Post Anchoring Systemm\ Typ. 6'-0" O.C. Post Spacing \l.` Pedestrian Guard Note: The handrail/fence post has been designed for a 200 Ibs concentrated horizontal load acting at the top of the post with a factor of safety of 1.5 againt overturning. The railing shall be designed for 50 Ibs per linear foot uniform load. The railing design is not included in the engineering, but the forces applied to the railing have been considered in the wall design Sleeve -It SD1 Fence -Post Anchor System Landscape Buffer Min 3 FT Bushes/Shrubs /— Non -Woven Filter 12" Soil Cover Reinforced Fill LANDSCAPE BUFFER DETAIL (Not to Scale) Sleeve -It SDI Fence -Post Anchor System - Top Dia. 7.4" Grout Fill After Post Installation w/ Min 3.000 Dsi Grout Bottom Dia. 9.4" Filter Fabric - 4 FT Wide Mirofi 140N or Equivalent cantilever Base 30.6"L x 15.3"W Soil Cover 23.4" Note: Shrubs can be planted behind the wall. The top geogrid layer can be cut using a utility knife for placement of the root bulbs. G YVQImf ILQi\�I�YR]iLf � �Si�M�SA4iB�1 Ta�ffisii6C ■fiQAL�.RHR.i4 �ICSSSt',PiB■��SSSi li•^� �� YM -fN� Start Geogrid Approx. 1" From Front of Units SRW Unit GEOGRID PLACEMENT DETAIL (Not to Scale) Reinforced Fill 4" Dia. Perforated Drain Pipe 12" Thick VDOT No. 57 Stone oO OO oO 00 00 Retained Soil If— 30.6u�ryvv'.r r~r:r1r1 Reinforced Fill / O rrr�r�r'r. r1r`rtir1r' O MICHAEL R. I y.titiyti •: •r.r.r r r ' "• ' �•• ' '' *�. �Lic. No.o021245 SLEEVE -IT FENCE POST DETAIL (Not to Scale) �tRrONAL E1 �aaaat V8" W r L Anchor Diamond Pro Units Wall Drain Pro (Weephole) at Max. 40' O.C. Drain to Daylight WALL DRAIN PRO DETAIL (Not to Scale) Circeo Geotechnical Engineering, P.C. 5956 Buckland Mill Road Roanoke, Virginia 24019 Phone:(540) 366-2379 Project No. I RW-2897 WALL A 75 75 75 75 74 O o } 74 74 N o 74 Q j d 74 — C 3 W 73 73 t O 73 N 73 73 72 72 Mill MHMMMMIMMMEMMN IMMIN ME —42" Tall Pedestrian Guard ----I�MI —■--------------•------•------��-------•------•--------------•---rMMIMM�— , 2,00 • 0 —■r------------••------••-----••------••------••------------••---••— C—ri— --u---r■—i r---i r■r--i ----i r--- r—r■—i r---i r■r-- r---i r--- r—r■— r---r■r-- r--r------r■— r—•�--■r—r ---r --��---r■—i r----•---� ----�---- r—r■—i r---i r■r-- ----� -------•-----r■r-------------•------•------- • r�.�.S17�ir�r�rY^ilriY�� low POMill Mel �o--n0000--•—nnoiri �rla irrr��rrr�rY^ilk•rl^-Irirrr��rr��rr�r�rY^ilrEffilffilt ■ - - --r— UM ire--_ �o•ri•.�r ir■--ur---. r--r■--r-- —�.--ur-----z■—rr—r • , • , • Men,i��r _ 1■■.i'�i' .�Ir■-rl■�r�Nel ... I■■Irir■�ri�r4`7ii'�..■��irl■�rirl■■Ir-Yrl■■Iri�r® I I I I GL=4.5FT I a=6FT I q = 750 psf •I �q = 1,000 psf I LEGEND ® Cap Unit (4" Height) 0 Anchor Diamond Pro Units (8" Height x 18" Width) Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) TOC Top of Cap Unit TOW Top of Wall (Excluding Cap Unit) BOW Bottom of Wall (Including Embedment) — 60 • — • StrataGrid SGU60 0 4" Drain Pipe to 5' VgNlcE Fqg, PG. Ste. 0 Station (ft) ENLARGED SITE PLAN Use Granular or Low Plasticity Soil in Reinforced Fill Zone RETAINING WALL A Sta. 0 to Sta. 120 Viewed From Front Face of Wall = Design Soil Bearing Pressure GL = 8 FT q = 1,250 p: WALL A w/ 42" Tall Pedestrian Guard Al 7 Scale: 1" = 30 FT 0 15 30 Circeo 5956 Buckland Mill Road Geotechnical Engineering, P.C. Roanoke, Virginia 24019 Lic. MICRR. I 9 Phone: (540) 366-2379 NNoo. 021245 a k+ 1"= loft. ZZ�v Scale: H' Sys G� V: 1"= loft. Project No. RW-2897 NAL ti� Date: 12/22/22 ""•• Revision: --- Sheet 5 of 12 WALL A 756 754 752 750 748 O 746 o t tt 744 t Cp 742 e 740 d 738 0 Iu 736 J s 734 u 0 732 730 728 726 TOC = 742,33 TOW = 742.00 6L=8FT 6L=8FT ii 1 Tall Pedestrian Guard Max. 3H:1V Backslope TOC = 742.33 TOW = 742.00 �� ���� ���� ���■� ���� �■��� ����--�� ���-- -- 1••IrirYstri r�ir �i•��r/•= ��pppY..IOO• : e rirl••Iri�ri•i�rrii•riii rirrrrirr■ram+ �O.II AT ___ ■ �WiVY• 6" Thick Stone Proposed Grade at Bottom of Wall Leveling Pad BOW = 736.00 i BOW = 734.67 (Low Point) Drain Pipe to Daylight - 40 FT O.C. (Typical) BOW = 734.67 (Low Point) 101 20 130 140 150 160 170 180 190 2210 21 2230 237 1 I I Station (ft) I I I I I I I GL=8FT I GL=6FT I GL=4.5FT q = 1,250 psf IN I go q = 1,000 psf IN I q = 750 psf LEGEND ® Cap Unit (4" Height) 0 Anchor Diamond Pro Units (8" Height x 18" Width) Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) TOC Top of Cap Unit TOW Top of Wall (Excluding Cap Unit) BOW Bottom of Wall (Including Embedment) 60 ' — ' StratoGrid SGU60 GL 0 4" Drain Pipe to Use Granular or Low Plasticity Soil in Reinforced Fill Zone RETAINING WALL A Sta. 120 to Sta. 237 Viewed From Front Face of Wall = Design Soil Bearing Pressure lsant Green - Albemarle Coui O '�PA Circeo 5956 Buckland Mill Road �� C✓ s Geot ineerial Roanoke, Virginia 24019 O MICHAEL R. I y _ Engineering, P.C. r9 C: � Phone: (540) 366-2379 Lic. No. 021245 1"= loft. FReVIC111sleon V: 1"= loft. Project No. RW-2897 A NAL �� 12/22/22 ...�a>� : --- Sheet 6 of 12 WALL B 75 TOC = 737.00 7 TOW = 736.67 74 0 7 6 o 74 7 co - 73 ruO 3 73 73 73 73 72 )0 1.67 0 SWTaTion GIL = 6 FT I GL = 8 FT 0.1 q = 1,000 psf q = 1,250 psf r-T �Ii LVI �-7 7i SMT;748'117 Hit IJFFE=759-3$ FAdLr '6 Sif .7 1 LOT 85 .- , :­ -C 33 SMT=A%x EASEMENT FF =76o. DIWAL" 7 .1 LOT ;rD V (MAX. HT. - 6') rFE=759. •88 WALLMAINTENANCE 87 .0, EAStmew'; BSMT=74 81, PG. ... ... : `15 .67 D.S. GARI LOT -FFE116 'go Ste. 2 BSMI= .50 1. .. 5 8. 74 LOT ..... ..... 0� .00 91 sta. 10 7" —sta. leo LOT ....... . 150 5 .60, ... ...sta5t �00§NiW_ 92 20 sta. 0 LOT Ste. go A' ROPOSED WALL 93 (MAX. HT. - 6') WALL b t 60 " ' r PROPOSEdWALIL PROPOSib UNDERGROUND STC (MAX. HIT. z: 61 FACILrrYC'- SEI sta. 3 "JMIT�'O'F SUNNY 74 P U WALL C DAY DAM BREACH Scale: 1" 30 FT WALL B w/ 42" Tell Pedestrian Guard ENLARGED S PLAN to 0 0 15 30 LEGEND Pleasant Green - Phase IIB/III Use Granular or Low Plasticity Soil P.LTn 0 Albemarle County, Virginia Gum= Cap Unit (4" Height) in Reinforced Fill Zone CIRCE0 GEOTECH Anchor Diamond Pro Units (8'* Height x 18" Width) 0 eo 5956 Buckland Mill Road C✓ Geotechnical Lewling Pad (Min. 6" Thick x 24" Wide Crushed Stone) Engineering, p C Roanoke, Virginia 24019 TOC Top of Cap Unit RETAINING WALL B MICHAEL R. I > Phone: (540) 366-2379 TOW Top of Wall (Excluding Cap Unit) (�o Lic. No. 021245 BOW Sta. 0 to Sta. 120 HI: 1"= loft. Bottom of Wall (Including Embedment) �6 /Z/2z/z.P' Scale: 60 'StrataGrid SGU60 Viewed From Front Face of Wall S'r 11P IV: 1"=Ioft. Project No. RW-2897 80 StrataGrid SGU80 10NAL '1-7 Date: 12/22/22 GI. Geogrid Length (ft) 0 4" brain Pipe to Daylight q Design Soil Bearing Pressure (psf)— 0'1,44�401 Revision: I --- Sheet 7 of 12 FA :. .. I • mmmmmmmmm Ems mmmm MEMO INS 1M OEM -MF1M C 740.33 _EEMM -MMMEMM== TOW = 740.00 I EMEM mmmmm mmmmmmmi mmmmmmmm MIMMMMMWAN mmms MEMEMMMEMMEEMENOMMEMETO MEMEMM •WE MIKE1111—ram I MIN mm I'Am MMMMEMMMM MOMMMMWAMEM m mmmm rmml=E a mms MMMMI =ME Am NOMMMIMMMEMI mmmmi mmmm mmmmi mommm mmmom m M ----- --- -------- S!II2 --------------- ---- -- - IWMMWE.gCmiolmop A ammimm MEE Proposed Grade at Bottom of Wall BOW 734.00 (Low Point brain Pipe to Daylight - 40 FT O.C. (Typical) NNN ....... 10 F na 1 30 40 50 60 70 80 90 100 110 q WALL B 756 Max. 3HAV Backslope 754 752 750 748 .. 746 d 744 0 742 a 740 m w 738 d W 736 J s 734 U 0 732 730 728 726 120 I I I� TOC = 741,00 TOW = 740.67 GL=8 FT GL=8FT 6L=8 FT _'BOW = 734.00 (Low Paint) 130 140 LEGEND ® Cap Vnit (4" Height) Anchor Diamond Pro Vnits (8" Height x 18" Width) Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) TOC Top of Cap Unit TOW Top of Wall (Excluding Cap Unit) BOW Bottom of Wall (Including Embedment) 60 • — ' Strato&rid SGV60 0 4" Drain Pipe to GL=8 FT FT FT 6" Thick Stone Proposed Grade at Bottom of Wall Leveling Pad Drain Pipe to Daylight - 40 FT O.C. (Typical) 150 160 170 I80 190 200 207 I Station (ft) I TOC = 738.33 TOW = 738.00 220 225 230 I 1 GL = 8 FT _ I GL = 6 FT No I q = 1,250 psf - 9 = 1,000 psf Use Granular or Low Plasticity Soil in Reinforced Fill Zone RETAINING WALL B Sta. 120 to Sta. 249 Viewed From Front Face of Wall = Design Soil Bearing Pressure x• EA1i OF MICHAEL R.� Lic. No. 021245 /2�/2zf22 tk7ONAL O ,L44H44� 35.67 TOW - 735.33 TOC = 736.33 / TOW = 736.00 M01111111110rr•BOW 734.00 (Low Point)co r. r�rrr• r•rrr• �s�rrr.r•rrr. 240 LT I GL=4.5FT I q = 750 psf neuounr vrcerr - rnuae aaoi iia Albemarle County, Virginia CIRCEO GEOTECH Circeo 5956 Buckland Mill Road Geotechnical Roanoke, Virginia 24019 L Engineering, P.C. 9 Phone:(540) 366-2379 Scale: H' I"= 10 ft, V: 1"= 10 ft. Project No. RW-2897 Date: 12/22/22 Revision: --- Sheet 8 of 12 WALL C 746 744 74z 740 738 0 736 a + 734-4 0) 0 732 � 730 ' V o d W 728 3 726 L L 724 } U) 722 720 718 716 I I TOC = 733.00 TOW = 732,67 OW = 730.67 Max. 3H:1V Backslope Wall B Above BOW 730.00 BOW = 728.00 = Proposed Grade at Bottom of Wall Drain Pipe to Daylight - 40 FT O.C. (Typical) �1 10 20 30 1 am 40 50 60 70 Station (ft) GL=10FT q = 1,500 psf 54• �I_7� �BSMT=74 zS �_ 851.83 =74.00 LOT LOT .-7 4- LOT —746 85._.- Ir 8WM iu1,v$ 86 ' EASEMENT - Daft AINTENANCE EASE D.B. PG. 744 PROPOSED WALL--- �+ (MAX.MAHT = V) AEN 0 G . c -5ta. Max. 3H:1V Backslope Tall Pedestrian Guard 6L=10FT 6L=10FT 1 I I BOW = 726.00 (Low Point) 80 T 83.. PG. 0 6" Thick Stone Leveling Pad GL=8FT q = 1,250 p: 5ta, 61%r k WALL D Sta. 30 - , . �, {� .,, Sta. 0 .��.._ �� 5ta. 0`� r ' r�c>,�-> WALL B �`P OPOSSEDD 'WALL r WALL C F�_. *+ (MAX. HT. = 6') w/ 42" Tall Pedestrian Guard �� DOSED WALL PROPOSED UNDERGROUND STORMWATER MANAGEMENT ' v HT. = 6'1 _ FACILITY'C' - SEE VSMP PLAN FOR DETAILS) I ENLARGED SITE PLAN (WP0202000053) 110 30 TOC = 733.00 TOW = 732.67 L-WALL E LSL( r Wn I6ol 120 I I Scale: 1" = 30 FT 015 30 LEGEND Pleasant Green - Phase IIB/III Use Granular or Low Plasticity Soil pLTH OF Albemarle County, Virginia ® cap Vnit (4Height) in Reinforced Fill Zone " O L CIRCEO GEOTECH ght � J Anchor Diamond Pro Vnits (8" Height x 18" Width) �. �Ci CGeotechnicalirceo 5956 Buckland Mill Road Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) F Engineering, P.C. Roanoke, Virginia 24019 TOC Top of Cap Unit RETAINING WALL C �; MICHAEL R. I > � 021245 No. Phone: (540) 366-2379 TOW Top of Wall (Excluding Cap Unit) •o Lic. cr 80W Bottom of Wall (Including Embedment) Sta. t0 Sta. 120 O� ��ZZ �L� H: A-- 60 ' Strato&rid SGV60 Viewed From Front Face of Wall �s Gti2 Scale: V: Project No. RW-2897 }'/ONAL tiDate: = Desi n Soil Bearin Pressure sf ' """`GL Geogrid Length (ft) O 4" Drain Pipe to Daylight q g g (p �Revision: Sheet 9 of 12 WALL C 746 Max. 3H:1V Backslope 744TOC = 733.00 742 TOC = 733.00 42" Tall Pedestrian Guard 740TOW = 732.67 TOW = 732.67 73$ GL=6 FT 736 t t .'�., 736 U u'f 0 732 o a^o 6L=8FT GL=8FT e 730 V N 6L=8FT 6L=8FT W a y W 728 6L=8FT 6L=8FT C 726 s 724 i BOW = 729.33 a 722 6" Thick Stone I 720 Leveling Pad — Proposed Grade at Bottom of Wall BOW = 726.67 718 BOW = 726.00 (Low Point) Drain Pipe to Daylight - 40 FT O.C. (Typical) 716 120 130 140 150 160 170 181.5 187.5 I l 6L=6FT Station (ft) I l q = 1,000 psf I _I I� 6L=8FT I q = 1,250 psf LEGEND Pleasant Green - Phase IIB/III Use Granular or Low Plasticity Soil EpLTH OF Albemarle County, Virginia ® Cap Unit (4" Height) in Reinforced Fill Zone p�� Lf,,P CIRCEO GEOTECH Anchor Diamond Pro Units Circeo 0 (8" Hight x 1a" Width) G'� 5956 Buckland Mill Road Geotechnical Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) O MICHAEL R. I y Engineering, P.C. Roanoke, Virginia 24019 roc Top of Cap Unit RETAINING WALL C A Lic. No. 021245 cc Phone: (540) 366-2379 TOW Top of Wall (Excluding Cap Unit) BOW Bottom of Wall g ) Sta. 120 to Sta. 187.5 'P �l�/ W (Including Embedment O� � ZC_�Q+ Scald. H' 1"= loft. 60 ' — ' StrataGrid SGU60 Viewed From Front Face of Wall �'s G� V: 1"= 10 ft. Project No. RW-2897 s L�ONAL ti� Date: 12/22/22 - Desi n Soil Bearing Pressure (psf) �``*6}g4 GI. G¢ogrid Length (ft) 0 4" Drain Pipe to Daylight q g g (p � Revision: --- I Sheet 10 of 12 • :. ..' w Backslope BEEN YiiYl.YwwwwwwwwY/wwwwww/YY - . . .. YwlYwwwwwwwwwY/wwwwww/YY /�/wwwwww/YwwwwwwwwwwwwY/wwwwwmom - /Y/wwwwww/YwwwwwwwwwwwwY/wwwwww/� wwwl wwwL-- �wwwwwwwwwwwY/wwwwww/YY wwwwwwwwwwwY/wwwwww/�� /Y/wwwwww/YwwwwwwwwwwwwY/wwwwww/Y /�/wwwwww/YwwwwwwwwwwwwY/ww wwwwww wwwww/Y wwwww/Y wwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/ww wwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/wr. wwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/w/� � wwwwwlYl wwwwww wwww�lw I wwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/wl� � wwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/ww wwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/II�w � wwww�IwY/wwwwww/YwwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/Ilwwwww Y wwwwY/wY/wwwwww/YwwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/I�wwwww/Y wwww�IwY/wwwwww/YwwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/wwwwww/Ywwwww_w_w_w_w_w_w_w_MMMMMMEM Y/iwwwww/Y _ mmmmi wwwwl�wY/wwwwww/YwwwwwwwwwwwwY■wwwwww/YwwwwwwwwwwwwY/wwwwww/YwwwwwwwwwwwwY/wwwwww/Y - �.--�wwY.wwwwwww wwww_wwrw/rw_..rwww rrilirw�--rwilwiw/YwwwwwwwY/wwwwwwwwwwwwwwY/wwwwww/Yw wwwwwwwwwwwwwwwww IYwi.nwnawY. Y•-� " wwwYw�Y/w�—r�`w wwol�wwAw�_-'• wwwwwww riwiwiir/irirYir. ■/wwwwww/ wwY 011SEMwY.wwwwww.Yw rwrYrwrilrairilYaw�Yw - wwwwwwY/ �Y wwwwwY/Y/ w Y - r � ®7/ w� ��ww�/wwwwww/ �w�w ^Iwo wwwwwwwwwwwwwwwww _ •�www��/ wwwwwwwwY/wwwwww/Yw _ mmmm www wwwwwwM-iwl�w®w+w� wwwww �Joi � Y/YWIIY.r�'YIYIY YY000i • w� �r��lY±� rYirwrYlYIYYrY v000Y�i/�Cww`O�i�_—_��—__------__—ww�wc•- Wry �� Job�v ar�w�w.� ar __wYt idea : : • • • :• • •o IN MEN MEN MEN . . SOMEONE 706 10 20 30 39 50 60 70 80 90 1100 111 I I I I i Station (ft) I I 1 6L = 14 FT GL = 1T I GL - 14 FT I 6 FI q = . I q = 2,250 psf I� q = 2,000 psf► I GAR=75 .00 1 - BS =T ao 6 FE=746.3 GAR =743• 4,1--f FE=751. 7 74o BSMT=73 .So I ; FFE744 =742.83.•�� 74��BSMT=734.5( LEGEND ® Cap Unit (4" Height) 0 Anchor Diamond Pro Units (8" Height x 18" Width) Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) TOC Top of Cap Unit TOW Top of Wall (Excluding Cap Unit) BOW Bottom of Wall (Including Embedment) 80 — StrataGrid SGU80 GL Geogrid Length (ft) 0 4" Drain Pipe to Dayli `—' LOT LOT 8 0' 7 .is. 3 EASEMENT - D.B. PG. D WALL 1 "I HT. = 69X--o�5t,< 7 f7/ I ;- 30 PG. — to. 9u Sta 3�0 5to. 60 Z 5ta, 60 1� _ -- '; WALL �`Sta. o ° ° -+� _ "" WALL \ 'PROPOSED WALL % E PROPOSED WA L WALL (MAX. HT. = 6')J ,, WALL C B I �! II ,I MAX. HT. = 4') SLOPES 3:1 0 O ';I STEE R THAN S ALH L BE PL, ENLARGED SITE PLAN STORMWATER MANAGEMENTS {� WITH ANNUAL RYEGRASS BY ERNST C01 Use Granular or Low Plasticity Soil in Reinforced Fill Zone RETAINING WALL D Sta.0 to Sta. III Viewed From Front Face of Wall = Design Soil Bearing Pressure ��pLTH pF Albemarle Circeo ✓ Geotechnical MICHAEL R. I y Engineering, P.C. UI)Lic. No. 021245 0� 1MWz_e__ w Scale: H: 1"= 10 ft. XJ` G� V: 1"= 10 ft. s"70NAL b� Date: 12/22/22 Revision: --- Scale: I" = 30 FT o15 30 5956 Buckland Mill Road Roanoke, Virginia 24019 Phone:(540) 366-2379 Project No. I RW-2897 WALL E 744 742 740 738 736 o 734 6 } 732 0 730 i 728 w -U p W 726 3 724 722 a 720 718 716 714 i • C • .. y ---r- ---r- •----i-ll •----�- -Na.. --•-!- IIMM N—_—�_ NNNi•NNNNNNNNNNNNNNNN•Ni •iNN�.---------i•NNNNNN•il- INN--r1�NNN•i—� _ Men �NNNNNNNNNieNNNNN—•-NNNN—NNNNN MA NNNNN- Imo---'--- �Ni•N —NNN Ml.NN NNN— NmN-A _._ --_,_ ---- --------_-- ___,-----_________NNN - --------------------`N��MR �� _ME _ Ir rlti��rr��rY—il�r�rr—ilr ����_������_�����WHE kA�--s �N-Ni•- •�n�NNNNN•iNNNN NNNi•NNNNNN•iNNNNMe I"—•��ii—���rh�rirl�---.lir��tiri•��—NNN—N_ YiViJrNN-- :• BOW = 726.00 INNNNNNi•NNNNNN•iN= —NNNNNin-NNNNN•iN �--..NNN-IIy�•iJl�i.i�o-.v---- 0000 : • � • • �� :• Proposed Grade at Bottam � • • - • � • • � � n0 10.5 20 I I I I GL=4.5FT I qq�I� 6L=45FT TOC = 729.00 TOW = 728.67 w o `o 3 } U) w — BOW = 726.67 = 726.00 of Wall O.C. (Typical) 30 40 50 60 66 I GL = 4.5 FT Station (ft) I I q = 750 psf GL=6FT I I �I F►► If q = 1,000 psf F�— EASEMENT - D.B. Sta. 60 (MAX. HT. = 6'r v '„` ` ENLARGED SITE PLAN STORMWATERMANAGEMENT I FFE=7 `742— BSMT PG. _ I�SLOPE5 STEE4R THAN 3a SQL BE PL, WITH ANNUAL RYEGRASS BY ERNST C01 Scale: V = 30 FT 015 30 LEGEND ricuau.,i UFMCF1 - rr.ua.a ��Pf� Use Granular or Low Plasticity Soil �Ir, O Albemarle County, Virginia in Reinforced Fill Zone ® Cap Unit (4" Height) FG CIRCEO GEOTECH [� ! 0 Anchor Diamond Pro Units (8" Height x 18" Width) %C = CGe-ot 5956 Buckland Mill Road ✓ GeotCeoechnical Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) '� LW En ineerin , P.C. Roanoke, Virginia 24019 roc Top of Cap Unit RETAINING WALL E C' MICHAEL R. I a ® 9 9 Phone: (540) 366-2379 TOW Top of Wolf (Excluding Cap Unit) Lic. No. 021245 BOW Bottom of Wall g ) Sta. 0 to Stu. 66 'P g �.��/ �V (Includin Embedment O ZZ Q H: 1"= loft. 60 — ' StratoGrid SGU60 Viewed From Front Face of Wall �s Gti? Scale. V: 1"= 10 ft. Project No. RW-2897 }R70NAL b� Date: 12/22/22 - Desi n Soil Bearing Pressure (psf) """'` GI. G¢ogrid Length (ft) 0 4" Drain Pipe to Daylight q g g (p � Revision: --- I Sheet 12 of 12