Loading...
HomeMy WebLinkAboutSDP202200067 Review Comments Final Site Plan and Comps. 2022-12-30a$ County of Albemarle m COMMUNITY DEVELOPMENT DEPARTMENT Site Plan Review Project title: Maplewood Development— Final Site Plan Project file number: SDP202200067 Plan preparer: Scott Collins, PE, Collins Engineering 200 Garrett Street, Suite K, Charlottesville, VA 22902 scott(&,,collins-ent ineering.com Owner or rep.: Maplewood Investments LLC 455 Second Street SE, Suite 201 Charlottesville, VA 22902 alan(a),,riverbenddev. com Plan received date: 27 Dec 2022 Date of comments: 30 Dec 2022 Review coordinator: Syd Shoaf Reviewer: John Anderson, PE 401 McIntire Road, North Wing Charlottesville, VA 22902-4579 Telephone: 434-296-5832 WWW.ALBEMARLE.ORG Engineering has completed review of the Final Site Plan, and offers the following review comments: 1. General (for ESP approval): a. Approved WPO required. b. WPO plan approval requires: i. Recorded SWM facility /public drainage easement, with deeds. ii. Recorded SWM facility Maintenance Agreement. iii. Recorded temp grading /access easement w/ TMP 46114-3. 2. Sheet 2: General Note 4., please clarify `the site is currently under construction,' since it does not appear to be. 3. Sheet 5: Provide copy of recorded variable width temporary grading and access easement on adjacent parcel, TMP 46134-3 (Forest Lakes Self -Storage); this item is required for Final Site Plan Approval. 4. Sheet 8: Increase pipe DIA pipe UGDI to Str. 38 to 24", since proposed 18" DIA capacity =8.28cfs while Qt=8.27cfs. 5. Sheet 9: A number of pipes are proposed 0.50% (Minimum). Flexible HDPE at 0.5% risks error that may be difficult or expensive to remedy if deflection or deformation relating to flat grade exceed max. tolerance. Encourage increase 0.50% slightly, if only to 0.55%, to offset risk during construction, to allow slight error. 6. Sheet 9: Revise lower -right text block reference to 2008 R&B Standards to ref. 2016 R&B Std., instead. 7. Sheet 10: For Caspian Lane, provide VDOT underdrain at cut /fill transition, Sta. 13+10 approx. 8. Increase Str. 16 DI throat length to 10', inlet is located on Drexel Lane, a principal access and final site plan inlet design table (VDOT LD-204), sheet 8A, SDP202200067 indicates Lt, this inlet=10.68' but inlet throat length provided is only 6' causing inlet carryover during 6.5" /hr. storm intensity event. 9. Sheet 3 a. Revise label /relocate leader line at SE comer of building #2 to `Proposed 5' conc. SW' that points to sidewalk. Engineering Review Comments Page 2 of 4 --------------i- --- f SET-9A6K - - - ______ i____i 12`, IM r PROPOSED (r) vuU t b t U. t TCONC. SIW RI-1 STOP SfW b. Entrance. Drexel Lane : driveway entrances. Caspian Lane : stop sign. Int. Drexel - Caspian. Entrance from Worth Crossing, drives, and stop sign at building 4, discussed below. It may be possible to preserve units and meet standards, but there is point at which maximum density meets design /safety standards, beyond which, spatial constraints limit number of units. Proposed buildings, internal network, recreational areas, additional parking, secondary emergency access, SWM, and aesthetic features reflect design that nearly meets (VDOT) standards. A stop sign at Drexel -Caspian must be visible (item 9.b.iv., below). At Applicant's discretion, two stop signs on Caspian may replace single stop on Drexel, revised thru-motion likely meets drivers' expectations. i. Provide >_ 35' throat length between curb at Worth Crossing and drive entrances nearest Worth Crossing (bldg. #2 and #3). See VDOT Road Design Manual, Apppx F, Sec. 4 Entrance Design, p. 104 for definition, Commercial Entrance (Drexel Lane -Worth Crossing is a commercial entrance), design subject to p. 109, Table 4-2, Summary of Entrance Throats, and Fig. 44A Entrance Throat Detail. Increase distance from curb to radius return, first driveway/s to > 35'. Number of Egress Lanes (left, thru and right) Minimum Throat Length Feet 1 35 2 75 3 200 4 300 TABLE 4-2 SUMMARY OF ENTRANCE THROATS Source: Transportation & Land Development 20d Edition 2003, Koepke and Stover Inadequate entrance length can also produce hazards to entering traffic on site. Particularly where the on -site parking can back out of and block the entrance and prevent a vehicle from entering. To avoid this problem, a distance of at least 50 feet is used on entrance length where back out parking may interfere with entry movement. Inwrrect Correct ------------- -------- FIGURE 4-1A ENTRANCE THROAT DETAIL Please compare with sheet 3 Entrance design --------------------- u--. (MINJ wJ_ I81ON Engineering Review Comments Page 3 of 4 � I RE __ ______F_____ ____ EZ � __' PARKING: BEGIN : . L}_�_______________9_ --_� /III' 'IPI911EEE9v1 ------------ - 1 RAAP I�TARI IPIVDOT ii. Revise drive entrances (all entrance) to show radii at each driveway. iii. Revise driveways of south -most units, building #4, so accessible, similar to blue -circle /check mark west -most units, building #2, which are accessible. The two south -most unit drives at bldg. #4 do not work. Design must ensure each unit has accessible, safe drive entrance without vehicles crossing travelway centerline, whether CL is marked or not. .._...._.. .. ,..--------------.....,.FPW .-1. CG2CUR6 PARKING ---'-- - _ SIGN 495'R CASPIAN LANE (28'PRIVATE ACCESS RMLSACE---- = IG VDOT - _ EASEMENT) PROPOSEDCU (P)G STD. CGe BCONIC. Sm IP)VlKIT am. wn RLf SGN 9'TYP IIII E 9•� I �jS ,LSP (P19lNE 51GH /Y\ I NO lVP P IG 9 r1 - I 1 .i__ 50.0' IPI T CGI .Ip R4 P u'00 (MIN.I GARAGE - I (P) VDOi STD. IPINO PARKING OG-12 ADA RAMP SIGN PROPOSED 5'CONC. SM • • ' S' f:DNC: 9NA \ 8 ACCESS ESMT - PROPOSED 22 E/P.E/P �E - 500' MULTI -FAMILY _ - PL, BUILDING#2 '- IPI NO 13 UNITS PARKING 9.710 SF �/ SIGN PROPOSED WEE MULTI-FAMIL' YCGA NGPO� _____ '-_ (P)Rp1-FACE '. CIIRRNI, __ - BUIL�ING #` - iv. South edge of building #4, < 1.0' to BC, Drexel Lane, obscures stop sign. Revise to ensure stop sign at Caspian -Drexel is visible and does not overhang the travel way. (P) STRE& SIGN 1--- (P) 00 STD. Thank you. Engineering Review Comments Page 4 of 4 (P) VDOT STD. / R1-1 STOP SIGN :' I I 1 iL ALV'-1 I rn (MIN.) 1 4. 0D GGARAGE --- r------I I I 1 I Please call if any questions — tel. 434.296-5832-x3069, or email 4anderson2(a)albemarle.org. SDP202200067_Maplewood Dev_FSP_123022.docx