Loading...
HomeMy WebLinkAboutARB201300032 Plan - Approved 2013-03-14N aTAW, = =IN %� Site I.D. 4793 Brand Name: Lane Bryant Address: Shoppers World Street 100 Shoppers World Court City, State Charlottesville, VA 22901 Township Name Albermarle County Contact Person: Stuart: 434 - 296 -5832 x3024 Keith: x3241 Brent Nelson ARB: x3438 Developer Contact Craig Smith CSmith @federalrealty.com or Stuart Biel sbiel @federalrealty.com Phone: 301 - 998 -8167 NOTICE - Letter heights preferred in the 30 -36" range and proportional. - No blade signs allowed at center. - Window vinyl reviewed on a case by case basis. - All signs are a maximum combined sign area of the linear width of the tenant space times one and a half (1 1/2), not to exceed two hundred (200) square feet. Must be channel letters. - Window signs; not to exceed twenty five (25 %) percent of the window. Included in maximum allowable area. - Maximum projection for wall signs is 12 inches. LANDLORD APPROVAL: CSI APPROVAL DATE: DATE: 30" 22" 20.125" DAY VIEW NIGHT VIEW (HALO -LIT) CUSTOM Halo -Lit Channel Letters - (Qty:1) As.Noted 89209 R2 Shoppers peers World World Court .. .... .. . .. Lane Bryant #4793 Charlottesville, VA 22901 2 - Commercial 54.609 So. Ft. Black Aluminum TBD /1 -20A circuit LED TBD Wall N/A N/A FACES AND RETURNS WILL BE OPAQUE. NO LIGHT WILL BE TRANSMITTED THROUGH FACE OR RETURN OF LETTER. 262 1 /8" 13 3/4" 102 3/8" 144 1 /4" 1113/8" 61 /2" Ei RYA N T\ DISCONNECT SWITCH ON END OF LETTER "T" ILLUMINATED LETTERS Scale: Y2' = 1' - 0" LED LAYOUT ONLY TBD ENERGY DATA Input Voltage (V DC) 12 Module Level Power (W /ft) 2.0 System Level Power (W /ft)* 2.25 Delivered Lumens (Lm /ft) ** 150 System Efficacy (Lm/W) 66 Viewing Angle (0) 120 .050 BLK/WHTALUMINUM RETURNS OUTSIDE OF LETTER TO BE Correlated Color Temp (K) 6300 PAINTED BLACK SATIN FINISH L70 Calculated Life (Hrs) ) * ** 99,000 INSIDE OF LETTER TO BE WHITE Typical Stroke (in) * * ** 6 WHITE LEDs ADHERED TO ACRYLIC Operating Temperature ( -40) to 60 °C / BACK FACING FRONT OF LETTERS ( -40) to 140 of 3/16" WHITE TRANSLUSCENT LEXAN * System power consumption, which includes power supply losses. BLACK LETTERS (LIGHT BKGDs) ** Estimated light output under application operating conditions. Scale: Not to Scale * ** Projected LED lumen maintenance based on the IED TM -21 model. Calculation is based on 10,000 hours of LM -80 data. Module average ambient temperature is 25 °C. ****For 5 inch deep can. I � BRYANTI 54.609 Sq. Ft. - NTS NOTE: UL sticker has to be present. Sign manufacturer's decals cannot be present. (No ]ones labels allowed) .090 ALUMINUM REMOVABLE FACE BLACK ALUMINUM SATIN FINISH NON- CORROSIVE MOUNTING HARDWARE AND SPACERS TO SUIT WALL 1/4" DIAMETER DRAIN HOLE W/ LIGHT BAFFLE (MIN. 2 PER LETTER) BLACK HALO -LIT CHANNEL LETTERS DETAIL VIEW Scale: Not to Scale LOW VOLTAGE WIRING THRU SLEEVE TO REMOTELY MOUNTED 120V x 12V POWER PACK WEATHER PROOF POWER SUPPLY DISCONECT SWITCH SHALL BE INSTALLED SIDEWAYS FOR TAMPER RESISTANCE 20 AMP PRIMARY ELECTRIC CIRCUITS BROUGHT TO SIGN AREA w/ FINAL CONNECTION BY SIGN INSTALLER WHERE LOCAL CODES ALLOW 6' WHIP LENGTH REQUIRED SILICONE CAULK ALL PENETRATIONS Conceptual Artwork Amanda Otto Date 04.08.13 Sales File Location Construction Drawing Date U Project Manager Janet Piccione Revision Notes DATE INITIALS NOTES 03.13.13 ATO Order #, Back Door Vinyl 04.08.13 ATO New Custom Ltr Dim. This Drawing Last Updated on: 04.08.13 CSI REQUIRES THAT DISCONNECT SWITCH BE LOCATED AT POINT OF POWER SUPPLY UNLESS CODE DICTATES OTHERWISE ALL SIGN WIRING AND DISCONNECT SWITCH TO ADHERE TO NEC CODE 600.6 I U.L. NOTE I CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF SIGN. THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTSOF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND /OR OTHER APPLICABLE LOCAL PRELIMINARY DRAWING ALL CONDITIONS MUST BE FIELD VERIFIED PRIOR TO FABRICATION I LL Approval I CSI Approval Back Board for Mounting Urs =2 -Commercial i N/A 1 N/A JL N/A BACKER PANEL PROVIDED BY LANDLORD 42" 'A 280" 0 Wall A As Noted 0 89209 R2 Shoppers World 100 Shoppers World Court Lane Bryant #4793 Charlottesville, VA 22901 Scale: 1/2" = 1' - 0" Letters (Previous Page) Mounted to Back Board for Mounting to Slanted Roof painted Gray PMS 423C Mounting Template for Itrs TBD Pre -Drill holes prior to painting. NOTE: BOARD DIMENSIONS & ATTACHMENT METHOD TBD LL Approval CSI Approval Conceptual Artwork Amanda Otto Date 03.13.13 Sales File Location Construction Drawing Date Project Manager Janet Piccione Revision Notes DATE INITIALS NOTES 03.13.13 ATO Order #, Back Door Vinyl 04.08.13 ATO New Custom Ltr Dim. his Drawing Last Updated on 04.08.13 CSI REQUIRES THAT DISCONNECT SWITCH 1E LOCATED AT POINT OF POWER SUPPLY UNLESS CODE DICTATES OTHERWISE ALL SIGN WIRING AND DISCONNECT SWITCH TO ADHERE TO NEC CODE 600.6 U.L. NOTE CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF SIGN. THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTSOF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND /OR OTHER APPLICABLE LOCAL STORE ELEVATION 2 - Commercial / N/A U1 A A ■ 20 wall ►0 Store Elevation - Day View (NTS) CL *FIELD SURVEY EXISTING CONDITIONS FOR INSTALLATION Store Elevation - Night View (NTS) *FIELD SURVEY EXISTING CONDITIONS FOR INSTALLATION As Noted 89209 R2 Shoppers World 100 Shoppers World Court Lane Bryant #4793 Charlottesville, VA 22901 A Conceptual Artwork Amanda Otto Date 03.13.13 Sales File Location LL Approval CSI Approval Construction Drawing I Date Project Manager Janet Piccione Revision Note DATE INITIALS NOTES 03.13.13 ATO Order #, Back Door Vinyl 04.08.13 ATO New Custom Ltr Dim. This Drawing Last Updated on: 04.08.13 CSI REQUIRES THAT DISCONNECT SWITCH BE LOCATED AT POINT OF POWER SUPPLY UNLESS CODE DICTATES OTHERWISE ALL SIGN WIRING AND DISCONNECT SWITCH TO ADHERE TO NEC CODE 600.6 U.L. NOTE CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF SIGN. THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTSOF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND /OR OTHER APPLICABLE LOCAL Store Elevation - Day View (NTS) *FIELD SURVEY EXISTING CONDITIONS FOR INSTALLATION F. F LL Approval CSI Approval This Drawing Last Updated on: I • 04.08.13 J CSI REQUIRES THAT DISCONNECT SWITCH BE LOCATED AT POINT OF POWER SUPPLY UNLESS CODE DICTATES OTHERWISE ALL SIGN WIRING AND DISCONNECT SWITCH TO ADHERE TO NEC CODE 600.6 U.L. NOTE CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF SIGN. THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTSOF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND /OR OTHER APPLICABLE LOCAL HITE OPAQUE WINDOW VINYL (Qty:9) As-Noted Shoppers World FM&2 89209_R2 100 Shoppers World Court Lane Bryant #4793 Charlottesville, VA 22901 o mmercial 9 .74 S . Ft. N/A N/A N/A N/A 2nd Surface N/A N/A Conceptual Artwork Amanda Otto 18.5" Date 03.13.13 3" ,� ♦ Sales 1 1/2" 1.25" ♦ ♦ File Location or 12" AFF Construction Drawing .74 Sq. Ft. WINDOW VINYL DETAIL Scale: 1 ' /2' = 1'- 0" Date 3M 220 -10 WHITE VINYL COPY LOGO AND WEBSITE APPLIED 2ND SURFACE ON WINDOWS 12" ABOVE FINISHED FLOOR Project Manager & CENTERED HORIZONTALLY ON THE WINDOW Janet Piccione WEBSITE FONT. BERTHOLD AKZIENZ GROTESK EXTENDED Revision Note DATE INITIALS NOTES 03.13.13 ATO Order #, Back Door Vinyl 04.08.13 ATO New Custom Ltr Dim. Store Elevation - Day View (NTS) *FIELD SURVEY EXISTING CONDITIONS FOR INSTALLATION F. F LL Approval CSI Approval This Drawing Last Updated on: I • 04.08.13 J CSI REQUIRES THAT DISCONNECT SWITCH BE LOCATED AT POINT OF POWER SUPPLY UNLESS CODE DICTATES OTHERWISE ALL SIGN WIRING AND DISCONNECT SWITCH TO ADHERE TO NEC CODE 600.6 U.L. NOTE CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF SIGN. THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTSOF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND /OR OTHER APPLICABLE LOCAL 16.00" Back Door Vinyl (Qty: i) Footage tuality Grade Square 2 -Commercial I N/A I Black Vi CGD \ /I! C nnnD \ /IKIVI I AV(1I IT A A PROTOTYPICAL SERVICE DOOR /DCDDCQCAITA Tin AI DI IDDn QCQI J iSLL��I li\ �JR•.LL.l 3M 220 -12 BLACK VINYL APPLIED FIRST SURFACE ON THE EXTERIOR OF WHITE / LIGHT COLORED DOORS W1 3.88" 1st Surface ■ N/A As Noted W1 89209 R2 Shoppers World 100 Shoppers World Court Lane Bryant #4793 Charlottesville, VA 22901 LL Approval CSI Approval Conceptual Artwork Amanda Otto Date 03.13.13 Sales File Location Construction Drawing Date Project Manager Janet Piccione Revision Note DATE INITIALS NOTES 03.13.13 ATO Order #, Back Door Vinyl 04.08.13 ATO New Custom Ltr Dim. This Drawing Last Updated on: ff . -- 04.08.13 CSI REQUIRES THAT DISCONNECT SWITCH BE LOCATED AT POINT OF POWER SUPPLY UNLESS CODE DICTATES OTHERWISE ALL SIGN WIRING AND DISCONNECT SWITCH TO ADHERE TO NEC CODE 600.6 U.L. NOTE CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF SIGN. THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTSOF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND /OR OTHER APPLICABLE LOCAL