HomeMy WebLinkAboutARB201300182 Plan - Approved 2013-12-18L O C A T I O N
SAL E S MA N
DESI G N ER
DA T E
CU S T O MER
X
X
X
X
X
A
B
C
E
D
1 S T D R A F Tname
NOTES FOR CHANGES
L O C A T I O N
SAL E S MA N
DESI G N ER
DA T E
CU S T O MER
X
X
X
X
X
A
B
C
E
D
Ph. 757-545-8802 • Fax. 757-543-9132
1044 Rur itan Blvd Chesapeake, VA 23324
Ph. 757-545-8802 • Fax. 757-543-9132
1044 Rur itan Blvd Chesapeake, VA 23324
C O P Y R I G H T 2 0 1 3 T A L L E Y A N C H O R S I G N C O .
This document is the sole property of Talley Anchor Sign Co. All designs,
manufacturing, reproduction, use and sales rights regarding the same are
expressly forbidden. It is submitted under a confidential relationship for a
special purpose, and the recipient by accepting this document assumes
custody and agrees that this document will not be copied or reproduced in
whole or in part, nor its contents revealed in any manner or to any person
except for the purpose for which it was tendered, nor any special features
peculiar to this design be incorporated in other projects.
C O P Y R I G H T 2 0 1 T A L L E Y A N C H O R S I G N C O . 1 S T D R A F TK NAILS & SPA LETTERS
70.6875”
17
”
NOTES FOR CHANGES
2013
2013
09/
CSE
RS
K NAILS
12/
12/09/
1
1-1
FRONT ELEVATION
1" = 12”
CHANNEL LETTERS
Info-
LED ILLUMINATED CHANNEL LETTERS
W/ LUCITE RED 2793 FACES
BRONZE TRIMCAP
& BRONZE RETURNS
RACEWAY PAINTED SYNERGY 342 PARCHMENT
THE LEVEL OF ILLUMINATION
PROVIDED BY THE LED LIGHTS,
WILL NOT EXCEED THE ILLUMINATION
PRODUCED BY A SINGLE STROKE
OF 30ma OF NEON.WALL
ELECTRICAL NOTES
Talley Anchor Sign Co. DOES NOT provide primary electrical to sign.
Power to the sign must be done by a licensed electrical contractor or licensed electrician.
1.A minimum of one dedicated 120V 20 A circuit
2. Junction box installed within 6 feet of sign
3.Three wires: Line, Ground, Neutral
Each sign must have:
RACEWAY-MOUNTED CHANNEL LETTERS
L.E.D. ILLUMINATION. DETAIL: N.T.S.
1. Faces: 3/16” translucent acrylic face fastened to
trim using a 2 part glue adhesive and activator
1“ trim fastened to2. Trim caps
returns with #8 x1/2“ Thred cutting screw.
Quality LEDs for optimal impact3. Illumination:
.043” Aluminum, 5” deep painted &4. Returns:
fastened to R/W
.063 Alum. or better fastened to5. Chnl Backs:
returns with 1/8ӯ pop rivets
Self contained - power supplies, 6. Power Supply:
Input 120VAC Electrical feed through (1) greeneld
wall penetration, Output 12VDC wired to LEDs
through J-Box.UL Listed J-Box mounted for connection
to main electrical.
7” (high) x 7” (deep) .063 Alum. formed7. Raceway:
R/W with easy access lid to service power supply.
1-1/2“ bridge supports internally welded across top.
U.L. listed, weatherproof disconnect box and 8. Switch:
switch located on exterior surface of R/W side.
R/W mounted to wall with required anchors9. Application:
fastened through formed angle.
1/4” drain holes drilled at lowest 10. Weep Holes:
point in each channel box.
2 3 4 5
6
7 9
10
1
2
3 4 5
7
8
9
10
6
L O C A T I O N
SAL E S MA N
DESI G N ER
DA T E
CU S T O MER
X
X
X
X
X
A
B
C
E
D
1 S T D R A F Tname
NOTES FOR CHANGES
L O C A T I O N
SAL E S MA N
DESI G N ER
DA T E
CU S T O MER
X
X
X
X
X
A
B
C
E
D
Ph. 757-545-8802 • Fax. 757-543-9132
1044 Rur itan Blvd Chesapeake, VA 23324
Ph. 757-545-8802 • Fax. 757-543-9132
1044 Rur itan Blvd Chesapeake, VA 23324
C O P Y R I G H T 2 0 1 3 T A L L E Y A N C H O R S I G N C O .
This document is the sole property of Talley Anchor Sign Co. All designs,
manufacturing, reproduction, use and sales rights regarding the same are
expressly forbidden. It is submitted under a confidential relationship for a
special purpose, and the recipient by accepting this document assumes
custody and agrees that this document will not be copied or reproduced in
whole or in part, nor its contents revealed in any manner or to any person
except for the purpose for which it was tendered, nor any special features
peculiar to this design be incorporated in other projects.
C O P Y R I G H T 2 0 1 T A L L E Y A N C H O R S I G N C O . 1 S T D R A F TK NAILS & SPA LETTERS
NOTES FOR CHANGES
2013
2013
09/
CSE
RS
K NAILS
12/
12/09/
CHANNEL LETTERS
Info-
RELOCATE K NAILS LETTERS &
INSTALL NEW SET OF “& SPA”
K NAILS & SPA