HomeMy WebLinkAboutARB201400035 Plan - Approved 2014-03-18s, n D N J 0 m METAL ROOF- SEE NOTE EXIST TECTUM REMAIN GUTTER AND DOWNSPOUTS SEE NOTE 1 REMOVE AND MTL FASCIA INSULATION- EXIST PREFINISHED MTL INSUL PANEL TO REMAIN NOTES: EAVE (DEMO) DETAIL 3/4 " =1' -0" Al EXISTING EXHAUST STACK TO REMAIN- TYP EXISTING ROOF VENT TO REM{ TYP APPROXIMATE LOCATION OF EXISTING ROOF STRUCTURE T( REMAIN- TYP ROOF DRAIN NOTE 1- TYP 1. REMOVE AND DISPOSE OF EXISTING METAL ROOF SYSTEM, GUTTERS, DOWNSPOUTS AND FASCIA. AREAS OF ROOF THAT HAVE BEEN REMOVED SHALL REMAIN WEATHER TIGHT DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY WEATHER PROTECTION AS NEEDED. 2. ALL ROOF DRAINS, ROOF PENETRATIONS EXHAUST STACKS ETC. ARE APPROXIMATE LOCATIONS AND WILL NEED TO BE FIELD VERIFIED. ALL ABANDON VENTS AND EXHAUST STACKS SHALL BE REMOVED AND CAPPED BELOW NEW ROOF SYSTEM. 3. ANY ITEMS THAT ARE REQUIRED TO BE REMOVED IN ORDER TO COMPLETE WORK SHALL BE REINSTALLED IN WORKING ORDER AS PART OF THE CONTRACT. ITEMS THAT MAY BE DISABLED DURING CONSTRUCTIONS (ANTENNA, EXHAUST STACKS, ETC.) THAT NEED TO BE REMAIN IN SERVICE DURING CONSTRUCTION SHALL BE COORDINATED WITH OWNER TO LIMIT ANY SERVICE INTERRUPTION. 4. ADMINISTRATION BUILDING SHALL REMAIN IN OPERATION DURING ENTIRE ROOF REPLACEMENT. CONTRACTOR SHALL FULLY PROTECT ALL INGRESS AND EGRESS POINTS, WALKWAYS AND ANY OTHER ACCESSIBLE AREA FROM ANY POTENTIAL HAZARD ASSOCIATED WITH ROOF REPLACEMENT. EXAMPLES OF HAZARDS ARE FALLING DEBRIS, DEBRIS AT GRADE, STORED MATERIAL AND ASSOCIATED ROOFING EQUIPMENT. THIS LIST OF EXAMPLES IS NOT ALL ENCOMPASSING AND DOES NOT RELIEVE CONTRACTOR FROM ISOLATING OTHER HAZARDS ASSOCIATED WITH WORK. HAZEN AND SAWYER Environmental Engineers & Scientists 96' -2" ANTENNA ATTACHED TO FASCIA TO REMAIN 40' -0" DEMO ROOF PLAN 1 /16" =1' -0" M PAI 0 i N N AREA OF DEMO It a 0 0 0 0 CD STANDING SEAM METAL ROOF - SNOW FENCE HAT CHANNEL- SEE NOTE * - SELF- ADHERED UNDERLAYMENT 3" RIGID INSUL EXIST TECTUM /PERMADECK -- PT BLOCKING GUTTER GUARD h U, 6 "X6" PREFINISHED AL GUTTER W/ 4 "X5" DOWNSPOUTS SPRAY INSULATION EXISTING BLOCKING PREFINISHED MTL FASCIA W/ DRIP EXIST PREFINISHED MTL INSUL PANEL (2) 1" X 16GA X 5-0" S.S. STRIPS TACK WELE TO CONTAIN MESH ' \ #2 S.S. SQUARE 0.63" WIRE MESH GUTTER STRAP ANCHOR PREFINISHED METAL RIDGE TRII OFF -SET CLEAT SEALANT APPLIED AT INTERSECTION OF HEAD CLOSURE TRIM TO 2' VERTICAL PANEL LEG--N PANEL CLOSURE PANEL CLIP — PANEL HAZEN AND SAWYER Environmental Engineers & Scientists 1' y EAVE DETAIL 3/4 " =1' -0" A2 NOTE: NO FASTENER PENETRATIONS THROUGH PANEL AT RIDGE METAL DECK, TYP FASTENERS TWO PER CLIP - FIX PANELS AT FIRST PANEL CLIP ilk 1"Aaw DETAIL 2 NTS A2 EXISTING EXHAUST STACK TO FA REMAIN- TYP EXISTING ROOF VENT TO REMAIN - TYP APPROXIMATE LOCATION OF EXISTING ROOF STRUCTURE- TYP ROOF DRAIN SEE NOTE 1- TYP — SEALANT AT SOFFIT PANELS NOTE 4- TYP- EXISTING SUPPLY VENT TO REMAIN IN SOFFIT TURN UP PANEL PAN FASTENERS ® SEAMS ANTENNA ATTACHED TO FASCIA TO REMAIN NOTES: EAVE, TYP 96' -2" 2 RIDGE A2 TRIM 40' -0" 1. APPROXIMATE LOCATION OF DOWNSPOUTS, FIELD VERIFY, TYPICAL OF 13. DOWNSPOUTS SHALL TIE INTO EXISTING DRAINAGE SYSTEM. VERIFY THAT EXISTING SITE DRAINAGE IS PROPERLY DRAINING PRIOR TO CONNECTING DOWNSPOUTS. 2. INSTALL GUTTER GUARDS ON ALL GUTTERS. 3. ALL ROOF DRAINS, ROOF PENETRATIONS EXHAUST STACKS ETC. ARE APPROXIMATE LOCATIONS AND WILL NEED TO BE FIELD VERIFIED. RECONNECT DOWNSPOUTS TO BELOW GRADE DRAINAGE SYSTEM. VERIFY BELOW GRADE DRAINAGE SYSTEM IS OPEN PRIOR TO RE- CONNECTION. 4. REMOVE AND REPLACE EXISTING SEALANT AT SOFFIT PANELS TO PROVIDE AIR BARRIER. 2 SNOW FENCE, TYP A3 ROOF REPLACEMENT PLAN 1 /16 " =1' -0" t o 0 0 0 0 °n Y n IL N 0 v o� N FLAT STOCK PANEL CUT TO ALLOW FOR EXPANSION AROUND PIPE HAZEN AND SAWYER Environmental Engineers & Scientists PANEL FFEN JtU I IUIV SET FLAT STOCK PANEL IN CONT BED OF SEALANT AROUND ENTIRE CUT OUT OPENING IN PANELS. BE SURE THAT RIVETS ARE COMPLETELY SEALED. FLATTEN PANEL RIBS AT POINT. OF BOOT INTERSECTION TO ALLOW BOOT TO NEST FLAT AGAINST PANEL PAN j o 0 o o PLAN PIPE VENT DETAIL NTS Al N PLAN STANDING SEAM ROOF CLAMP AT EACH BATTEN — STANDING SEAM METAL `—SNOW CLIP, MINIMUM TWO ROOFING SYSTEM BETWEEN EACH BATTEN OR AS REQD BY SNOW FRONT VIEW FENCE MANUFACTURER Lam, ISOMETRIC SIDE VIEW NOTE: PROVIDE ADDITIONAL SNOW FENCE ROWS AS REQ'D TO SUPPORT THE SNOW LOAD REQUIREMENTS AND PER THE SNOW FENCE MANUFACTURERS RECOMMENDATIONS SNOW FENCE DETAIL 2 NTS A2 !M411%