Loading...
HomeMy WebLinkAboutARB201400064 Plan - Approved 2014-05-07zz a z 167.5" (SIGN BAND) 11'- 3" 19.4" 18" O _ O C Raceway Painted SW 6341 Red Cent (1) 18" ILLUM. LETTER SET ON RACEWAY IN SIGN BAND TOTAL : 12.5 SQ FT I TRIM CAPS ARE WHITE AND RETURNS ARE BLACK. .Raceway = SW 6341 Red Cent Ovals - Arlon 2500 -52 dark gray Ovals and Letters = 2nd surface white 3M3630 -20 ❑WHITE LEDs Internal Illumination NOTE: THE LEVEL OF ILLUMINATION PROVIDED BY THE LED LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED BY A SINGLE STROKE OF 30 MILLIAMP (MA) NEON please J)lW-W,Jr1lt:ft: Renderings are torgrapnic purposes only and not intended toractual construction dimensions. t-orwinaloaa requirements, actual dimensions and mounting detail, Everbrite These drawings .. or d prohibited. Customer: State Farm Description: 18" Channel Letter Set. Customer Approval: Graphics and colors on file will be used unless otherwise specified by customer. Please review drawing carefully. By signing below, you agree to graphics as Project No: 309613 -3 Scale: NTS shown above, and to location of sign as shown. Please return signed copy back to Everbrite. Date: 5/19/14 Drawn By: DB Location & Site No: Charlottesville, VA Revised: CUSTOMER SIGNATURE DATE SF16543 Revised: I LANDLORD SIGNATURE DATE m rn LED MODULE —\ (8) 1/2" DIA. MOUNT HOLE IN RACEWAY DISCONNECT SWITCH 18" WHITE LETTERSET TRIMCAP: WHITE RETURENS:BLACK 1. OVERALL DIMENSIONS OF SIGN HEIGHT: 19.562" WIDTH: 134.687" DEPTH: 9.125" 2. AREA OF SIGN - SQUARED: 18.30 SQ.FT. 3. ILLUMINATION: LEDS US LED WHITE PT3 -3 -12W 4. POWER SUPPLY: INPUT: 120 VAC 0.96 AMPS OUTPUT: 12 VDC 60 WATTS MAX. 5. TOTAL LINE LOAD: 0.96 AMPS @ 120VAC 6. (1) 20 AMP CIRCUIT, 60Hz UL 48 & NEC COMPLIANT 7. EST.WEIGHT OF DISPLAY: 140 LBS NOTE: THE LEVEL OF ILLUMINATION PROVIDED BY THE LED LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED BY A SINGLE STROKE OF 30 MILLIAMP (MA) NEON. FRONT VIEW SCALE 1:16 0 MIA00y 0 11' -5" RACEWAY FRONT VIEW SCALE 1:16 (1) 7/8" DIA. ELECTRICAL INLET ON BACK OF RACEWAY I w ii w N st � 1S a 1 CONTINUOUS BLOCKING (AS REQ'D) PLASTIC TRIM CAP W /SCREW (8) 3/8" DIA. FASTENER/HARDWARE (TYPE & LENGTH T.B.D. BY INSTALLER ON SITE) SIGN FACE PVC SLEEVE @ COMPRESSIBLE WALL FINISH SYSTEM (IF REQ'D) CONDUIT TO REMOTE POWER SOURCE (INSTALLER TO PROVIDE UL LISTED CONDUIT & FITTINGS, AND MOUNTING HARDWARE) RACEWAY SERVICE COVER RACEWAY (1) 7/8" DIA. ELECTRICAL ROUTE HOLE (1) POWER SUPPLY MOUNTED INSIDE RACEWAY NOTE: WALL STRUCTURE VARIES PER SITE. LED MODULE 1. OPEN PACKAGING CAREFULLY AND INSPECT FOR DAMAGE. IF DAMAGE IS FOUND, CLAIM MUST BE FILED WITHIN 15 -DAYS WITH SHIPPING AGENT. 2. DETERMINE SIGN LOCATION AND TAPE UP THE PROVIDED TEMPLATE ON THE SURFACE TO WHICH IT WILL BE INSTALLED, RECEIVE CONFIRMATION FROM CLIENT OR CONTRACTOR. 3. LAYOUT AND PRE -DRILL ALL MOUNTING AND ELECTRICAL HOLES REQUIRED FOR MOUNTING THE SIGN ON THE WALL IT IS TO BE INSTALLED. 4. FILL ALL HOLES WITH SILICONE PRIOR TO MOUNTING THE SIGN. 5. ATTACH THE HORIZONTAL BLOCKING (AS REQ'D) BEHIND WALL SO ALL CONNECTION POINTS HAVE SUPPORT. 6. ALIGN LETTERS TO MATCHING PRE - DRILLED HOLES WHILE INSERTING FASTENERS THROUGH LETTERS, WALL AND BLOCKING. FASTEN WITH WASHERS & NUTS (IF APPLICABE. USE PVC SLEEVES TO PROTECT BUILDING FINISH SYSTEM OVER SHEATHING. 7. MAKE FINAL ELECTRICAL HOOK UP TO PRIMARY WIRING OF POWER SUPPLIES THROUGH DRILLED ELECTRICAL HOLES. 8. TEST LIGHT THE SIGN TO ENSURE THE SIGN IS LIGHTED AND FUNCTIONING PROPERLY. 9. PERFORM TOUCH -UP AS REQUIRED 10. CLEAN UP: CLEAN INSTALLATION WORK SITE OF ALL EXCESS MATERIALS AND DEBRIS. (DO NOT DISCARD ANY MATERIAL OR DEBRIS INTO ON SITE DUMPSTERS.) U) Z 0 W A RELEASED FOR INSTALL Qf REV. DESCRIPTION SECTION VIEW SCALE 1:8 GENERAL NOTES INCLUDE COMPLETION PHOTOS OF MOUNTING /CONNECTION POINTS, WIRE ROUTING AND OVERALL ELEVATION. THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRIC CODE AND /OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. INSTALLER TO BE SURE SIGN IS PROPERLY INSTALLED, CONNECTED AND GROUNDED. IT IS THE INSTALLERS RESPONSIBILITY TO SF16543 OOD THESE DRAWINGS ARE THE EVERBRITE, LLC. PROPERTY USE OF, OR F o 000000, o IDENTIFY CONDITIONS AND ADAPT TO WEEP HOLE(S) THESE VARIATIONS AS NEEDED fi0 +m CHARLOTTESVILLE, VA 222911 -7593 M. M0 4949 SO. 110TTH ST. WALL FINISH SYSTEM OVER SHEATHING DRN BY SAJ (INSTALLER TO IDENTIFY TYPE & THICKNESS) SCALE AS SHOWN DWG NO. REV. WALL STRUCTURE (VARIES) ,000 Ooo° 0000 P.O. BOX 20020 GREENFIELD, WI 53220 6-20-14 (T.B.D. BY INSTALLER ON -SITE) RHB DRIP HOLE @ ALL 0184 ELECTRICAL SPECS. 5 LETTERS & LOGO A (1) LED 60W 12V POWER SUPPLY °o0 00, -..106 00 0 ® o ° 414 - 529 -3500 CHK BY 0.96 AMPS EACH (INPUT) Fs PIF REF DATE DRN TOTAL 0.96 AMPS @ 120 V p H B 6 -20 -14 309613 'USE (1) 20 AMP CIRCUIT 1. OPEN PACKAGING CAREFULLY AND INSPECT FOR DAMAGE. IF DAMAGE IS FOUND, CLAIM MUST BE FILED WITHIN 15 -DAYS WITH SHIPPING AGENT. 2. DETERMINE SIGN LOCATION AND TAPE UP THE PROVIDED TEMPLATE ON THE SURFACE TO WHICH IT WILL BE INSTALLED, RECEIVE CONFIRMATION FROM CLIENT OR CONTRACTOR. 3. LAYOUT AND PRE -DRILL ALL MOUNTING AND ELECTRICAL HOLES REQUIRED FOR MOUNTING THE SIGN ON THE WALL IT IS TO BE INSTALLED. 4. FILL ALL HOLES WITH SILICONE PRIOR TO MOUNTING THE SIGN. 5. ATTACH THE HORIZONTAL BLOCKING (AS REQ'D) BEHIND WALL SO ALL CONNECTION POINTS HAVE SUPPORT. 6. ALIGN LETTERS TO MATCHING PRE - DRILLED HOLES WHILE INSERTING FASTENERS THROUGH LETTERS, WALL AND BLOCKING. FASTEN WITH WASHERS & NUTS (IF APPLICABE. USE PVC SLEEVES TO PROTECT BUILDING FINISH SYSTEM OVER SHEATHING. 7. MAKE FINAL ELECTRICAL HOOK UP TO PRIMARY WIRING OF POWER SUPPLIES THROUGH DRILLED ELECTRICAL HOLES. 8. TEST LIGHT THE SIGN TO ENSURE THE SIGN IS LIGHTED AND FUNCTIONING PROPERLY. 9. PERFORM TOUCH -UP AS REQUIRED 10. CLEAN UP: CLEAN INSTALLATION WORK SITE OF ALL EXCESS MATERIALS AND DEBRIS. (DO NOT DISCARD ANY MATERIAL OR DEBRIS INTO ON SITE DUMPSTERS.) U) Z 0 W A RELEASED FOR INSTALL Qf REV. DESCRIPTION SECTION VIEW SCALE 1:8 GENERAL NOTES INCLUDE COMPLETION PHOTOS OF MOUNTING /CONNECTION POINTS, WIRE ROUTING AND OVERALL ELEVATION. THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRIC CODE AND /OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. INSTALLER TO BE SURE SIGN IS PROPERLY INSTALLED, CONNECTED AND GROUNDED. STRTE RN 19 9116" LED LOGO & III LED LETTERS ON RA lw wa COUNT SF16543 OOD THESE DRAWINGS ARE THE EVERBRITE, LLC. PROPERTY USE OF, OR F o 000000, o � ��T° CHARLOTTESVILLE, VA 222911 -7593 o 4949 SO. 110TTH ST. DRN BY SAJ DATE 6 -20 -14 SCALE AS SHOWN DWG NO. REV. DUPLICATION IN ANY MANNER WITHOUT EXPRESS WRITTEN ,000 Ooo° 0000 P.O. BOX 20020 GREENFIELD, WI 53220 6-20-14 SAJ RHB N 0184 5 P A PERMISSION OF EVERBRITE, °o0 00, -..106 00 0 ® o ° 414 - 529 -3500 CHK BY DATE PIF REF DATE DRN CHK p H B 6 -20 -14 309613 INC. IS PROHIBITED. °