HomeMy WebLinkAboutARB201400083 Plan - Approved 2014-06-26SIGN A 28" H &R Block
Channel Letters on a Raceway
• Internally Illuminated LED
.T 5.44 +12.30 =17.74
To . - Top of sign to grade = 16' -1"
Bottom of sign to grade = 13' -9"
O
o
� N
&R BLOCK
Client: H &R BLOCK
• 06/19/2014
Permit Rendering
NK
This rendering is the property of AnI
Sign, Inc. It is for the exclusive usSite
Anchor Sign, Inc. and the party wH
requested the rendering. It is
unpublished original drawing not tCharlottesville,
distributed, reproduced ho e 9 , without the consent of Anchor Si n, Please contact your account manwith questions regarding this statem
07/09/2014
Updated returns, vinyl specs
NK
#: HR -44755
Address: 249 Connor Dr.
•
VA 22911
SIGN A 28" H &R Block
Channel Letters on a Raceway
Internally Illuminated LED
. ,. 5.44 +12.30 =17.74
To . - Top of sign to grade = 16' -1"
Bottom of sign to grade = 13' -9"
Sylvania 71071 White 6500K LEDs
(2) 60w Transformer @ 0.61 amp ea
Total Amps: 1.22
(1) 20 amp 120V Circuit Req. U� LISTED
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
1) Grounded and bonded per NEC 600.7 /NEC 250
2) Existing branch circuit in compliance with
NEC 600.5, not to exceed 20 amps
3) Sign is to be UL listed per NEC 600.3
4) UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer*
'For multiple signs, a disconnect is permitted but
not required for each section
12'- 101/2" 1154
28" 1 8" 9'- 101/2" 1118
I
co
D
N Q I __ 7nn
I
HR -IL 28 RW Sign Layout Detail
Scale: 1/2" = V -0"
1. Existing Facade: EIFS over Plywood over metal studs
2. 0.040" Aluminum letter returns painted to match Black
3. 0.125" x 1" trim cap painted to match Black
4. 3mm Signabond Lite composite backs
(interior of sign can painted ultra white for maximum illumination)
5. Sylvania 71071 White 6500K LEDs *
6. 3/16" White #2447 Acrylic. Block logo with 3/16 White Acrylic and first surface
applied 3M #3630 -106 Brilliant Green vinyl (PMS 376 C Green equivalent)
7. Waterproof disconnect switch per NEC 600 -6
8. Primary electrical feed
9. Transformers
10. 0.080" Aluminum raceway painted to match SW 6120 Believable Bluff
11. 15" x 2" x 0.1875" Aluminum mounting tabs welded to raceway
- Maximum 6" from each end and every 48" o.c.
12. #12 x 1" TEC screws with 11/4" fender washers
13. 3/8" Thru Bolts w/ 1 5/8" x 1 5/8" 12 gauge Uni -Strut backer
* The level of illumination provided by the L.E.D. lights will
not exceed the illumination produced by a single stroke of
30 milliamp (ma) neon.
L`rrriu
- icuci Cana tom) Vc icu
Section (a-)- LED Channel Ltr/ Raceway
Front -Lit Scale: N.T.S.
H &R BLOCK
D
Client: H &R BLOCK
• 06/19/2014
Permit Rendering
NK
This rendering is the property of Anchor
Sign, Inc. Sig islnc. and theupart use
Anchor Sin y
requested the rendering. It is an � •
without the consent of the
unpublished original drawing not to be
distributed, reproduced or exhibited
Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Site #: HR -44755
Address: 249 Connor Dr.
07/09/2014
Updated returns, vinyl specs
NK
•
Charlottesville, VA 22911
H &R BLOCK
lih 28" H &R Block
Channel Letters on a Raceway
Internally Illuminated LED
5.44 +12.30 = 17.74
Top of sign to grade = 16' -1"
Bottom of sign to grade = 13' -9"
Charlottesville, VA
H &R BLOCK
■
Client: H &R BLOCK
• 06/19/2014
Permit Rendering
NK
This rendering is the property of Anchor
Sign, Inc. Sig is for and theupart which
Anchor Sin y
requested the rendering. It is an •
without the consent of the
unpublished original drawing not to be
distributed, reproduced ho exhibited
Sign, Inc.
Ic. 1 , ,
Please contact your account manager
with questions regarding this statement.
07/09/2014
Updated returns, vinyl specs
NK
Site #: HR -44755
Address: 249 Connor Dr.
•
Charlottesville, VA 22911