Loading...
HomeMy WebLinkAboutSDP202200064 Review Comments Minor Amendment 2023-01-23Cameron Langille Principal Planner, Planning County of Albemarle blangille@albemarle.org Community Development Department - Department Telephone: (434) 296-5832 ext. 3432 Memorandum To: Steve.kellett@us.mcd.com; permitting@commun-et.com Date: January 23, 2023 Re: SDP202200064 McDonald's at 1294 Stony Point Road Minor Site Plan Amendment - Review Comments The County of Albemarle Planning Division will grant or recommend approval of the plan referenced above once the following comments have been addressed: [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] Albemarle County Planning Division (Planner) Comments - Cameron Langille, blangille@albemarle.org - Requested changes: 1. [General Comment] Please update the site plan title on the cover sheet so that it states "Minor Site Plan Amendment - SDP202200064." 2. [18-32.5.2 (a)] Update the zoning note on the cover sheet so that it states that the property is within the FH Flood Hazard Overlay District and the Preserved Steep Slopes Overlay District. 3. [32.5.2 (b)] Please state the square footage of the existing building on the cover sheet. 4. [32.5.2 (b)] Please provide a parking calculation on the cover sheet. Per Section 18-4.12.6, restaurants are required to have 13 spaces per 1,000 square feet of gross floor area including areas for accessory dancing. 5. [18-32.5.2 0); 18-32.5.2 (I)] Please show and label all existing easements on the site plan. State the easement type, dimensions, and state the recorded instrument number that created the easement in a label for each existing easement. 6. [18-4.12.16) Please label the dimensions of all proposed parking spaces on Sheet C3.0. 30-degree angled parking spaces must be a minimum 9' x 18' and must be adjacent to a one-way travelway that is a minimum of 12' wide. The two parking angled spaces adjacent to the dumpster at the southwest parcel corner do not appear to meet this requirement. a. [18-4.12.15 (e)] The two parking spaces next to the dumpster pad extend into the dumpster pad on Sheet C3.0. Per the Zoning Ordinance, parking spaces cannot encroach into any loading aisles. Staff suggests removing those two parking spaces from the site plan. Please revise the cover sheet and the provided parking table on Sheet C3.0 so that they state that 35 parking spaces are provided. Based on staff's review of the proposed parking, there are only 35 parking spaces that meet dimension requirements shown on Sheet C3.0. 7. [18-32.5.2 (n)] Please label the surface materials and dimensions all travelways, drive -through lanes, sidewalks, and other hardscape features on the plans. a. Per the drive-thru dimension details shown on Sheet C3.1, the drive -through lanes do not meet the minimum 11' width requirement of Section 18-5.1.60 (g). Please revise the drive -through lanes so that they meet the minimum 11' width requirement. WWW.ALBEMARLE.ORG 401 McIntire Road, North Wing, I Charlottesville, VA 22902-4579 b. Please be advised that the travelway adjacent to the drive -through lanes must be a minimum of 12' wide adjacent to 35-degree angled parking, as specified in Sections 18-4.12.17(c), and 20' wide when adjacent to perpendicular parking as specified in Section 18-4.12.16 (c)(1). 8. [18-32.5.2 (1); 18-5.1.60 (1)] The travelway on the south side of the building is shown as a two-way travelway. However, there is no landscaped separation feature as required by Section 32.7.9.5 (b), (c), (d), and (e). The travelway should be revised so that directional arrows indicate that it is for one-way travel only. See Engineering comment #3 for further information. a. Sheet C3.0 keynote #3 references detail SD-1.2 on Sheet C3.1. If the travelway is revised to be one-way, please update the directional arrow detail on SD-1.2 so that it only contains a one-way directional arrow. 9. [18-32.5.2 (p);18-32.7.9] Keynote #7 on Sheet C2.0 indicates that some existing landscaping will be removed. Please provide more specificity on the exact landscaping within that area that is proposed to be removed. If any of that landscaping was required on the previous site plan (SDP199900123) to meet the landscaping regulations of Section 18-32.7.9 of the Zoning Ordinance, a landscaping plan may be needed to demonstrate compliance with all applicable landscaping regulations for the site. 10. [18-32.7.8; 18-4.17] Please see ARB comment #2. Please update the details on Sheet SD-1.1 to specify the level of illumination for the canopy board LED lighting. A lighting plan demonstrating compliance with all applicable regulations contained in Section 18-4.17 of the Zoning Ordinance may be required. a. [38-32.7.8] Please indicate whether any other new outdoor lighting is proposed. Please contact Cameron Langille in the Planning Division by using blangille@albemarle.org or 434-296-5832 ext.3432 for further information. Comments from Other Reviewers: Albemarle County Engineering Division - Matt Wentland, mwentland@albemarle.org - Requested changes, see attached. Albemarle County Architectural Review Board (ARB) - Kris Taggart, ktaggart@albemarle.org - Requested changes, see attached. Albemarle County Building Inspections - Betty Slough, bslou¢hC@albemarle.ore - Review not yet complete, comments or approvals will be forwarded to the applicant upon receipt. Albemarle County Department of Fire & Rescue - Howard Lagomarsino, hlaeomarsino@albemarle.ore - Requested changes, see attached. WWW.ALBEMARLE.ORG 401 McIntire Road, North Wing, I Charlottesville, VA 22902-4579 Review Comments for SDP202200064 MinorAmendment Project Name: SDP1993-18 - MINOR Date Completed: Tuesday, December 13, 2022 Department/DivisiordAgency: Review Status: Reviewer: Matthew Wentland - CDD Enoineerina Requested Changes 1. Ine minimum wiatn of a anve-tnru lane is 1r twoemane County coae 1ts.5.l.tw.g�. 2. When making adjustments to the lane widths, keep in mind the minimum width of the one-way access aisle is 12' when 30 degree angled parking is used (18.4.12.16.c.3). Further clarification of the table in this section of the ordinance can be found in the Design Standards Manual (located on our website). 3. The drive -through lane located adjacent to the two-way internal travelway shall be separated from one another by a landscaped area that complies with section 32.7.9.5(b), (c), (d), and (a) and is at least ten feet in depth extending the length of the drive -through lane (18.5.1.60.1). The travehvay may need to be made one-way. 4. Parking spaces should not block access to the dumpster (18.4.12.15.e) Page: 1� County of Albemarle Printed On: 01 /17/2023 Review Comments for SDP202200064 MinorAmendment Project Name: SDP1993-18 - MINOR Date Completed: Thursday, January 05, 2023 Department/Division/Agency: Review Status: stopherTaggart CDDARB Requested Reviewer:Khn I have reviewed the above -noted application. The following revisions are requested to make the proposal consistent with the Entrance Corridor Guidelines. 1. The detailed drawings for the drive-thru equipment does not specify the proposed color for the yellow shown throughout the drawings. Revise the submittal to include the Pantone equivalent for the yellow proposed. 2. The drive-thru springboard canopy structure notes LED downlighting but does not mention the proposed level of illumination. Revise the submittal to provide the proposed level of illumination at the ground for these canopies. Page: 1 County of Albemarle Printed On: 01 /171202 Review Comments for SDP202200064 Minor Amendment Project Name: 1 SDP1993-18 - MINOR Date Completed: Tuesday, January 10, 2023 Department/Division/Agency Review Status: Reviewer) Howard Lagomarsino Fire Rescue Requested Changes No Objection once below added as a note on the plans: 1) During demolition and/or construction, the following fire prevention steps are required, so please note them on the plan: a) Smoking shall be prohibited in areas where smoking is a hazard and these areas shall be designated with no smoking signs per Virginia Statewide Fire Prevention Code b) Areas where smoking can occur, shall have appropriate receptacles for discarded smoking materials per Virginia Statewide Fire Prevention Code. c) Contractor shall ensure the street numbers are always plainly visible from the frontage street during construction per the Virginia Statewide Fire Code. d) Per the Virginia Statewide Fire Prevention Code, safe and efficient vehicular access for firefighting and emergency operations shall be provided and maintained at all construction and demolition sites. This includes provision of the required unobstructed access fire department connections within 100 feet of water supply/hydrants for this connection. e) An approved water supply for firefighting operations shall be in place with unobstructed accessibility as soon as combustible materials arrive on site. f) Waste and combustible debris shall be removed at the end of each day and disposed of in accordance with the Virginia Statewide Fire Code - g) Fire extinguishers shall be provided, with not less than one approved fire extinguisher in areas where combustible materials have accumulated, in every storage and construction shed and in areas of special; hazards, such as where flammable and combustible liquids are stored or used, in accordance with the Virginia Statewide Fire Code. h) Operations involving the use of cutting and welding shall comply with the Virginia Statewide Fire Prevention Code and shall require a permit from the Albemarle County Fire Marshal's Office. Page. 1 County of Albemarle Printed On: 01 /17/2023