Loading...
HomeMy WebLinkAboutCLE202300013 Application 2023-01-24Zoning Clearance Application FOR OFFICE USE ONLY Fee Amount: $ 54 Receipt #: Clearance Number: Date Paid: By: Check #: BY Albemarle County -rPllu, r Community De elognmt 401 MclMire Rd, North Wing ^<. Chedottes tle, VA 22902 �rRC/^1�P Phone 434. 296. 5832 Applicant - Fill out the entire page below And return to Community Development 401 McIntire Rd, North Wing, Charlottesville, VA 22902 Name: Peter Tremaglio E-Mail address: ptremag@gmaii.com Mailing Address: 1035 Locust Ave Charlottesville VA 22901 Phone #: 202.538.5202 Tax Map and Parcel number and/or Address of the Business: 03200-00-00-019c3 4035 Hunterstand Court Charlottesville, VA 22911 Zoning: Staff will fill out if unknown Parcel Owner: FOUR REASONS LLC Owner's Address: 1029 GRAND ISLE DR, NAPLES FL.3410&3324 Check any that apply: New Business ❑ Change of Use Change of Ownership Change of Name Business Name: Pepper Mill Service LLC DBScrl ption of BUSIneSS' Describe the business including use, number of employees, number of shifts, availability of parking, and any additional info. We are an event rental business. We will be warehousing and distributing event equipment (tables, chairs, glasses, linen, etc.). We will run one shift of 5-10 employees. The site has ample parking. Previous Business on site: AKER WADE POWER TECHNOLOGIES, LLC Floor Plan' Please attach either an architectural drawing or a sketch of the proposed business indicating the location of uses, the uses of rooms, the total square footage of the use, and any additional information. Total Square Footage Used for the Business: 13560 Is the Parcel Zoned LI, HI, or PDIP? F0 Yes n No If yes, fill out a Certified Enoineers Report (CER1 Will there be food preparation? ❑ Yes F0 No If yes, provide Virginia Department of Health approval Is the Parcel on public water or private well? Public Private If on private well, provide Virginia Department of Health approval Is the Parcel on public sewer or septic? FV� Public Septic If on septic, provide Virginia Department of Health approval Will you be putting up any new signage? Yes [0 No If yes, obtain appropriate sign permit and list permit # below Will there be new construction or renovations? Yes V No If yes, obtain appropriate building permit and list permit # below Please list any applicable Building Permit #s: Zoning Clearance review cannot begin until the application above is complete and all applicable forms and fees are submitted. This Clearance will only be valid on the parcel for which it is approved. If you change, intensify, or move the use to a new location, a new Zoning Clearance will be required. I hereby certify that I own or have the owner's permission to use the space indicated on this application. I also certify that the information provided is true and accurate to the best of my knowledge. I have read the conditions of approval, and I understand them, and tha�tQI will abide by them. Signature �"'" Printed Peter Tremaglio Date 1/24/2023 2 Albemarle County Zoning Clearance Application 0 Community Development 401 McIntire Rd, North Wing Chedottesville, VA 22902 Phone 434.2965832 Applicant - If you are not the land owner, please fill out the entire page below confirming that you have either informed or are going to inform the owner of your zoning clearance application. CERTIFICATION THAT NOTICE OF THE APPLICATION HAS BEEN PROVIDED TO THE LANDOWNER I certify that I will provide (or have provided) notice of this clearance application, Pepper Mill Service LLC clearance number provided by Staff or business name to FOUR REASONS LLC the owner Name of landowner on record of Tax Map and Parcel Number 03200-00-00-019c3 by either delivering a TMP number of property copy of the application to them in person or by sending them a copy of the application by mail. (Please check one of the following below) ❑ Hand delivering a copy of the application to the owner identified above on Date 2 Mailing a copy of the application to the owner identified above on Date 1 /24/2023 1029 Grand Isle Dr Naples FL, 34108 to the following address: (Written notice to the owner and last known address on our record books will satisfy this requirement. Please see staff for help determining this information if needed) Signature of Applicant /M Applicant Name Printed Peter Tremaglio Date 1/24/2023 3 For Albemarle County Staff Review Only Proposed Use: Permitted: ❑ Yes ❑ No Permitted by Section: Supplementary Regulations: Applicable Special Use Permit (SP): Applicable Rezonings (ZMA): Applicable Site Plans (SDP): Parking: If there is an approved site plan associated with the parcel, the parking requirements will be defined by the SDP. Some parking requirements are determined by a ZMA or by an approved Code of Development. Parking Formula: Defined by: I ❑Site Plan ❑Zoning Ordinance ❑ CoD ❑Existing Total Square Footage of the Use: Required number of parking spaces: Associated Clearances: Variances: Violations: Is a site inspection necessary?: ❑ Yes ❑ No Site Inspection on (date): To Confirm: Notes: Conditions of Approval: Additional conditions of approval apply to Fireworks and Christmas Trees Approval Information ❑ Approved as proposed Approved with conditions J Denied ❑ Backflow prevention device and/or current test data needed for this site. Contact ACSA, 434.977.4611 ext. 117 ❑ No physical site inspection has been done for this clearance. Therefore, it is not a determination of compliance with the existing site plan. ❑ This site complies with the site plan as of this date. Conditions: Additional Notes: Building Offic Date Zoning Official Date Other Official County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Phone: 434.296.6632 Fax: 434.972.4126 4 January 24, 2023 Community Development Department Division of Zoning and Current Development 401 McIntire Road Charlottesville, VA 22902 To the County Engineer: We are a small business renting event equipment. We will be located at 4035 Hunterstand Ct, Charlottesville VA 22911. The location will function as our office and warehouse to store and distribute chairs, tables, glasses, linen, etc. We plan to have four employees in our warehouse and two in the office. We have addressed the performance standards of Zoning Ordinance Section 18-4.14: Noise: Our operation will not create sound or impact noise levels more than the values specified in Section 4.14.1. We are surrounded by industrial buildings on three sides and an embankment on the fourth. Our major sources of noise are: 1) music and telephones. 2)deRvery vehicles. Vibration: No equipment will produce any detectable earthborn vibration. Glare: Our operation is completely contained within the building. The interior lighting associated with this operation do not produce glare that is visible beyond the lot line. Air Pollution: There will be no emission of smoke, odor, or gaseous pollutants. Water Pollution: No liquid wastes will be generated by this operation. Our operation does not represent a hazard to water quality. Radioactivity: My operation does not require handling of radioactive materials. There will be no radioactive emissions. Electrical Interference: My operation does not require any equipment that would generate electrical disturbances. Please feel free to contact me with any further questions you may have at 202.538.5202 or by e-mail at ptremag@gmail.com. Sincerely, Peter Tremaglio COUNTY OFALBEMARLE Department of Community Development 401 McIntire Road Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 MEMORANDUM TO: Zoning Clearance or Home Occupation Applicant FROM: Zoning Division RE: Request for Approval of Letter of Performance Standards or Certified Engineer's Report Proposed Business/Use: Pepper Mill Service LLC Address: 4035 Hunterstand Ct Charlottesville, VA 22911 Re CLE (Zoning Clearance Number): HO (Home Occupation Number): Contact Person: Peter Tremaglio Phone Number: 202.538.5202 Fax Number: Date Faxed to Applicant: Please return this form along with all required documentation to the Zoning Division upon completion. Thank you. To be completed by staff: Approved: Comme CER Packet Revised 2/11109 Certified Engineer's Reports According to Zoning Ordinance section 18-4.14.8, Albemarle County requires a certified engineer's report prior to issuing a zoning compliance clearance or home occupation permit for uses of an industrial character. The certified engineer's report must be reviewed by the County Engineer (or designee). A certified engineers report shall consist of; Type 1: For uses which will have no discharge, noise, vibration, smell, lighting, emissions, impulses or radiation beyond a normal office or residential use, and will not store any hazardous materials, a letter from the owner with the following information will suffice as a certified engineer's report; 1. a description of the business and the physical process involved. 2. a description of any machinery and operations. 3. a statement or explanation for meeting each of the performance standards of section 18-4.14, noise, vibration, glare, air pollution, water pollution, radioactivity, electrical interference. Examples of type 1 uses might be offices or warehouse storage of clothes or home occupations for wood workers. An example letter is available. Type 2: For uses which will have any discharge, noise, vibration, smell, lighting, emission, impulse or radiation which might reasonable be expected to exceed the performance standards of 18-4.14.4 at any time, or which have any permit requirements from DEQ, EPA, Health Department or other local, state or federal agency, a full certified engineers report is required. This report must contain a signed and dated seal from a professional engineer. It must contain copies of any local, state or federal permits. It must contain plans and descriptions of physical and operational measures to meet all of the performance standards, with actual supporting measurements and data where applicable. Examples of type 2 uses might be a contractor's office and storage yard or equipment repair shop, or a manufacturer of electrical components. 2 CER Packet Revised 2/11/09 4.14 PERFORMANCE STANDARDS No use shall hereafter be established or conducted in any industrial district in any manner in violation of the following standards of performance: 4.14.1 NOISE All sources of noise (except those not under direct control of occupant of use, such as vehicles) shall be subject to and comply with section 4.18. (§ 4.14-12-10-80; Ord. 00-18(3), 6-14-00) 4.14.1.1 (Repealed 6-14-00) 4.14.1.2 (Repealed 6-14-00) 4.14.2 VIBRATION The produce of displacement in inches times the frequency in cycles per second of earthborne vibrations from any activity shall not exceed the values specified below when measured at the points indicated. 4.14.2.1 METHOD OF MEASUREMENT Earthborne vibrations shall be measured by means of a three component recording system, capable of measuring vibration in three mutually perpendicular directions. The displacement shall be the maximum instantaneous vector sum of the amplitude in the three directions. 4.14.2.2 MEANING OF TERMS Vibrations means the periodic displacement of oscillation of the earth. Area of Measurement Type of vibration At residential district boundaries At other lot lines within district Continuous .00 .015 Impulsive (100 per 006 .030 Minute or less) Less than 8 pulses 015 .075 per 24 hours 4.14.3 GLARE No direct or sky reflected glare, whether from flood lights or from high temperature processes such as combustion, welding or otherwise, so as to be visible beyond the lot line, shall be permitted except for signs, parking lot lighting and other lighting permitted by this ordinance or required by any other applicable regulation, ordinance or law. However, in the case of any operation which would affect adversely the navigation or control of aircraft, the current regulations of the Federal Aviation Administration shall apply. CER Packet Revised 2111/09 4.14.4 AIR POLLUTION Rules of the State Air Pollution Control Board shall apply within Albemarle County. Such rules and regulations include coverage of: emission of smoke and other emissions from stationary sources; particulate matter; odor; particulate emission from indirect heating furnaces; open burning; incinerators; and gaseous pollutants. 4.14.5 WATER POLLUTION Rules of the State Water Control Board shall apply within Albemarle County. 4.14.6 RADIOACTIVITY There shall be no radioactivity emission which would be dangerous to the health and safety of persons on or beyond the premises where such radioactive material is used. Determination of existence of such danger and the handling of radioactive materials, the discharge of such materials into the atmosphere and streams and other water, and the disposal of radioactive wastes shall be by reference to and in accordance with applicable current regulations of the Department of Energy, and in the case of items which would affect aircraft navigation or the control thereof, by applicable current regulations of the Federal Aviation Administration, and any applicable laws enacted by the General Assembly of the Commonwealth of Virginia or the requirements of the Virginia Air Pollution Act, whichever is greater. 4.14.7 ELECTRICAL INTERFERENCE There shall be no electrical disturbance emanating from any lot which would adversely affect the operation of any equipment on any other lot or premises and in the case of any operation which would affect adversely the navigation or control of aircraft, the current regulations of the Federal Aviation Administration shall apply. 4.14.8 CERTIFIED ENGINEER REPORT SUBMITTAL Each future occupant of an industrial character shall submit to the county engineer as precedent to issuance of a zoning compliance clearance a certified engineer's report describing the proposed operation, all machines, processes, products and by-products, stating the nature and expected levels of emission or discharge to land, air and/or water or liquid, solid or gaseous effluent and electrical impulses and noise under normal operations, and the specifications of treatment methods and mechanisms to be used to control such emission or discharge. The county engineer shall review the applicant's submittal and make comment and recommendation prior to final commission action on the site development plan. (Amended 9-9-92) CER Packet Revised 2111/09 EXAMPLE LETTER FOR TYPE 1 CERTIFIED ENGINEER'S REPORT [Date] Community Development Department Division of Zoning and Current Development 401 McIntire Road Charlottesville, VA 22902 To the County Engineer: We are a small mail order business distributing clothing and fan based products. We store t-shirts, hats, and jewelry, and package them for distribution. We have four employees in our warehouse, and three employees at call centers in the warehouse office. We have addressed the performance standards of Zoning Ordinance Section 18- 4.14: Noise : Our operation will not create sound or impact noise levels in excess of the values specified in Section 4.14.1. We are surrounded by an embankment on three sides and a block wall on the fourth. Our major sources of noise are: 1) music and telephones. 2) truck deliveries of merchandise. Vibration: We operate no equipment in our warehouse. Glare: Our operation is completely contained within the building. The interior lighting associated with this operation does not produce glare that is visible beyond the lot line. Air Pollution: There will be no emission of smoke, odor or gaseous pollutants. Water Pollution: No liquid wastes will be generated by this operation. Our operation does not represent a hazard to water quality. Radioactivity: My operation does not require handling of radioactive materials. There will be no radioactive emissions. Electrical Interference: My operation does not require any equipment that would generate electrical disturbances. Please feel free to contact me with any further questions you may have at [telephone] or by e-mail at [e-mail address]. Sincerely, [Name of applicant] CER Packet Revised D11/09 EXAMPLE LETTER FOR TYPE 1 CERTIFIED ENGINEERS REPORT [Date] Community Development Department Division of Zoning and Current Development 401 McIntire Road Charlottesville, VA 22902 To Whom it May Concern: We are a small business building custom cabinets and furniture with four employees and are currently starting a shop at (address of your business). The parcel is zoned Industrial (L-1). It is my understanding that in order to occupy this space we will need to submit this Letter of Performance Standards along with our zoning clearance application. We have addressed the standards referenced in Section 4.14 and provided the following responses: Noise Our operation will not create sound or impact noise levels in excess of the values specified in Section 4.14.1. We are surrounded by an embankment on three sides and a block wall on the fourth. Our major sources of noise are: 1) outside 5hp Air Compressor that runs five minutes during an hour throughout the day. It is enclosed in a dog house to protect it from weather and to cut down noise; 2) dust collection system, located outside with a 3hp electric motor develops a low noise level; and 3) Inside shop equipment includes a 10" table saw, 3 hp shaper, 20: surface planner, 24" surface sander, 8 by 56" joiner/planner, drill press, radial arm saw, and assorted hand held power tools, all of which do not have an unacceptable noise level. Vibration Equipment operated by shop does not produce any detectable earthborn vibration. Glare Our operation is completely contained within the building. The interior lighting associated with this operation does not produce glare that is visible beyond the lot line. CER Packet Revised 2/11/09 Air Pollution There will be no emission of smoke, odor or gaseous pollutants. By-product of the operation is saw dust. A dust collection system has been installed to remove airborne saw dust from each station to an outside collection per OSHA standards. System is self contained and does not represent a hazard to air quality. Water Pollution No industrial liquid wastes will be generated by this operation. All finishing will be handled off -site by a local finishing company, because of this there will be no paints, lacquers or solvents store on site. A permit has been issued by the Health Department on our sewage disposal. Our operation does not represent a hazard to water quality. Radioactivity My operation does not require handling of radioactive materials. Therefore there will be no radioactive emissions or danger to health and safety of person on or beyond the premises. Electrical Interference My operation does not require any equipment that would generate electrical disturbances that would adversely affect the operation of equipment on any other lot or premises. Please feel free to call me with any further questions you may have. Sincerely, [Name of applicant] CER Packet Revised 2/11/09