HomeMy WebLinkAboutSUB202200125 Approval - Agencies 2023-01-31 (2)RGINIA
VI) HOF IHEA DEPARTMENT
Protecting You and Your Environment
Sewage Disposal Certification Letter Approval
December 8, 2022
Stockton Creek, LLC
C/O Alan Taylor
455 Second Street SE, #201
Charlottesville, VA 22902
RE: Tax Map: 69-19F (Site 17-1 & 17-2)
HDID:101-22-0403
Page I of 3
Albemarle County Health Department
1138 Rose Hill Drive
Charlottesville, VA 22903
(434)972-6219 Voice
(434) 9724310 Fax
APPROVED
Important Note: Certification Letter Approval for Site DF 17-1 & 17-2
Dear Alan Taylor,
This Certification Letter is issued in lieu of a sewage disposal system construction
permit in accordance with §32.1-163, et seq., of the Code of Virginia. The Board of Health
hereby recognizes that the soil and site conditions acknowledged by this correspondence, and
documented by additional records on file at the local health department, are suitable for the
installation of an onsite sewage disposal system. The attached plat shows the approved area for
the sewage disposal system. This letter is valid until a permit for construction is issued and the
system is installed, inspected and approved. This letter is void if there is any substantial physical
change in the soil or site conditions where the sewage disposal system is to be located.
The application for a certification letter was submitted pursuant to § 32.1-163.5 of the
Code of Virginia which requires the Health Department to accept private soil evaluations and
designs from an Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation
with an OSE for residential development. The site for an individual onsite sewage system was
certified as being in compliance with the Board of Health's regulations by: Chris Heltzel,
AOSE License 1940001460. This letter is issued in reliance upon that certification.
A permit to construct the sewage disposal system must be issued before construction of
the system. If the property owner (current or future) applies for a construction permit within I E
months of the date of this letter, the application fee paid for this letter shall be applied to any
state fees for a permit to construct a sewage disposal system. After 18 months, the applicant is
responsible for paying all state fees for a permit application.
Tax Map: 69-19F (Site 17-1 & 17-2)
HDID: 101-22-O403
Page 2 of 2
This letter, and accompanying plat of survey showing the specific location of the sewage
disposal system area and well area (if applicable), may be recorded in the land records by the
clerk of the circuit court in the jurisdiction where all or part of the site or proposed site of the
system is to be located. The site shown on the plat is specific and must not be disturbed or
encroached upon by any construction. To do so voids this letter. Upon the sale or transfer of the
land that is the subject of this letter, the letter shall be transferred with the title to the property.
Future owners are advised to review the plat for the location of the onsite sewage disposal area to
make sure their building plans do not interfere with the area. If they have any questions
regarding the location of the area, they should contact the local health department for assistance.
The area evaluated, and certified by this letter, is suitable to accommodate a 5 bedroom
house using a system design of 750 gallons per day. The property will be served by a Private
water supply as shown on the attached plat. Owners are further advised that when connection to
a public water system is proposed and the public water system has reached its permitted capacity,
a permit for construction may not be issued until such time that a connection is approved and
available for use.
This letter is an assurance that a sewage disposal system construction permit will be
issued (provided there have been no substantial physical changes in the soil or site conditions
where the system would be located); however, it is not a guarantee that a permit for a specific
type of system will be issued. The design of the sewage system will be determined at the time of
application for a building permit and sewage system construction permit. The design will be
based on the site and soil conditions certified by this letter, structure size and location, water well
location (final determination to be made at time of permit issuance), the regulations in effect at
the time, and any off -site impacts that may have occurred since the date of the issuance of this
letter. In some cases, engineered plans may be required prior to issuance of the construction
permit. In accordance with § 32.1-164.1:1 of the Code of Virginia, owners are advised to apply
for a sewage disposal construction permit only when ready to begin construction.
This certification letter approval has been issued in accordance with applicable
regulations based on the information and materials provided at the time of application. There
may be other local, state, or federal laws or regulations that apply to the proposed construction of
this onsite sewage system. The owner is responsible at all times for complying with all
applicable local, state, and federal laws and regulations. If you have any questions, please contact
me.
Issued by:
41 /
Jodi Kirtley
Environmental Health Technical Consultant
COMMONWEALTH OF VIRGINIA
Application for: [D Sewage System ❑ Water Supply
Owner: Stockton Creek LLC Go Alan Taylor
Mailing Address: 455 Second Street SIE9 201
Charlottesville, VA 22902 _
Agent: Stockton Creek LLC Go Alan Taylor
Mailing Address: 455 2nd Street SE, Suite 201 Charlottesville, VA 22902
Site Address: TBD L
Afton, VA 22920
Directions to Property:
VON USE ONLY
Health DepL IDS I l 2 Z'(r' `�
Due Dace:
Phone: 512426-4728
Fax:
Phone:
Phone:—,-- 434-981-3634
Emati: ntmpsmn{�tteseonayutYtonmana�mem.eom
Subdivision: OF 17-1 & 17-2 Section: Block: Lot:
Tax Map: 69-19F Other Property Into: Acreage:
4.63
Sewage System
Type of Approval: Applicants for new construction are advised to apply for a ce0canort tetterro determine ifahe lard is sdhaHaefnr
a sewage
system and to apply for a construction permit (valid for 18 months) only when ready to butd.
ED Certification Letter ❑ Construction Permit ❑ Subdivison Approval ❑
Repair
Proposed Use:
Single Family Home (Number of Bedrooms) 5 Multifamily Home (Total A of Bedrooms)
Other (Describe):
Basement (] Yes Walk -Out Basement? ❑ Yes Fbdures In Basement? ❑
Yes
❑ No ❑ No ❑
No
Conditional Permit Desired? ❑ Yes Q No If yes, what type of conditions are desired?
❑ Reduced Water Flow ❑ Limited Occupancy ❑ intermittent or seasonal use ❑ Temporary Use (1 yr. ma)imum)
Do you wish to apply for a betterment loan eligibility letter ❑ Yes" No
"There is a $50 fee for determination of el'rgibg.q.
u
Water Supply
Will the water supply be ❑ Public or Private Is the water supply ❑ Existingor d Proposed
If proposed, is this a replacement well? ❑ Yes M No If yes, will the old well be abandorKKP ❑ Yes
❑ No
Will any buildings within 51Y of the well be termite treated? ❑ Yes O No
All Applicants
Is this a private sector OSE/PE application? El Yes ❑ No If yes, is the OSE package attached?
Q Yes
❑ No
Is the property intended to serve as your (the owners) prkrdpat place of rediderroe? ❑ Yes No
In order for VDH of process your application for a sewage system, you must attach a plat of the properly and a sae skatetL For water supplies, a
plat of the property Is recommenced and a site sketch Is required. The site sketch should show your properly lines, actual andfor proposed
buildings. and the desired location of your well and/or sewage system. When the site evaluation 1s conducted. the property Ones, building location
and the proposed wen and sewage sites must be dearly marked and the property suMdently visible to see the topography.
i give perm "" lb tld v A4' Vfterd ofM69M to enter onto the prop" described du M normal business hours for the purpose of
processin "! ppffcatlon and fd Oofkrn qualify assurance checks of evaluations and designs certified by a private sector Onaite Soil Evaivator
or Proho& Engineer as nepe the sewage dis t system and/or private water supply has been constructed and approved.
C CitRlgiO4�F y'1A60'7 �/
v� l Q I22 (Z C�
J . tyo.19'�W
Sianatu / :e Date
r9G'S (iYWC CiY�IWie�l
sage of -La
OSEIPE Report For:
Construction Permit ❑ Repair ❑ Voluntary Upgrade 21 Certification ❑ Subdivision Approval
-ernit Permit Letter
Property Location:
1911 Address: TBD _. City. State, Zip: Afton, VA. 22920
ILot: Section: Subdivision: DF 17-1 d 172
IGPIN or Tax Map #: 69-19F Health Dept ID It,
11-atltude: Longitude,
Owner : _
Name: Stockton Creek LLC do Alan Taylor
Address: 455 Second Street SE, # 201 Charloftesv(ile, VA 22902
pumu my.
E Name: Chris Hefhel
Iress: PO Box 554, Wood
Name:
:k. VA 22664
Date of Report: 10/22/2022 Date of Revision #1:
Date of Revision #2:
Contents/index of this report
1. Cover Sheet
I23. Sell Evaluation
16-7. AbbreviatedDesfyns
Statement
6. Ora"/less Media Specifications
9. Site Sketch
10. Drahrfleld Location & Sanitary Survey
License # 1940-001400
License #
I hereby certify that the evaluations and/or designs contain herein were conducted in accordance wWn the appilcabta provisions of the
Sewage Handling 6 Disposal Regulations (12VACS-610), the Private Wet) Regulations (12VAC5-630), the Regulations forAltemathre Onsite
Systems (12VAC5-613) and all other applicable laws, regulations, and policies implemented by me virgins Department of Health. i further
certify that I currently posses any professional license required by the laws and regulations of the Commonwealth that have been duty Issued
by the applicable agency charged with Iicensure to perform the work contained herein. The potential for both conventional and alternative
onsite sewage systems hjOq"d ATed with the ownerfappticar*
0 The4otk'�" to mis/co°+hj[ page has been canducbsd under an exemption to the precUm dren¢sneermg, specaodty to
en in Code of Vlrgirde, %ction 54.1-402A.11
I recommend th a` Qrfbnii'dGryrn•`Pertit ;.. ❑ Subdivision Approval be: Issued
FlEI_TZP.L � �
�v&,rt�,ter. e ❑ Re Permit E3 Voluntary Upgrade ❑ Denied
OSE/PE signature: Ova. Date:
- �� __ - �... Dale:
4•
9/10/2021
Page Z of io
SOIL SUMMARY REPORT
GENERAL INFORMATION
Submitted to: Albemarle County Heatth Department
Stockton Creek LLC c/o Alan Taylor Telephone Number: 512-426-47
455 Second Street SE, # 201 Charlottesville, VA 22902
Stockton Creek LLC Uo Alan Taylor Address: 455 2W Street SE, Setts 201 ChadottesYdle, VA2211M
Location: TBD Tax Map/GPIN: 69-19F
ion: Blk/Sec: Site: 1
1. Position in Landscape Satisfactory: 91 Yes ❑ No
Describe: Convex Upland Sideslope
2. Slope: 8-11 %
3. Depth to Rock or Impervious Strata: Max. 70"+ Min.
4. Depth to seasonal water table (gray mottling or gray color): Not Observed i]
5. Free Water Present? 0 No ❑ Yes Range:
S. Soil Percolation rate estimated: [A Yes Texture Group: 1 ❑ 11 ❑ III D
❑ No Estimated rate: 65 mpi g 24"
7. Permeability Test Performed? El No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
None P)
Yes ❑
inches
IV ❑
❑ Site Approved. Drainfield to be placed at 24 " depth at site designated on pertttit.
❑ Site Disapproved. See reasons tar rejection.
sons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table-
4 ❑ Rates of absorption too slow.
5 ❑ Insufficient area of suitable soil for drainfield and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages it necessary'}
Notes:
71age? of tU
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 9/10/2021 Submitted to: Albemarle County Health Department
Owner: Stockton Creek LLC c/o Alan Taylor Telephone Number: 512426-4728
caress: 455 Second Street SE, # 201 Charlottesville, VA 22902
!Agent: Stockton creek LLC do Alen Taylor Address: 455 2nd sheet SE, suite tot charaaeavlm, vA 2mz
(Property Location: TBD Tax Map/GPIN: 69-19F
!Subdivision: Bik/Sec: Site: 17-2
1. Position in Landscape Satisfactory: 2) Yes ❑ No
Describe: Convex Upland Sideslope
2. Slope: 6-9 % -- ----- -- ... _
3. Depth to Rock or Impervious Strata: Max. 60+" Min. 49" None ❑
4. Depth to seasonal water table (gray mottling or gray color): Not Observed 91 Yes ❑
5. Free Water Present? 12 No ❑ Yes Range: inches
6. Soil Percolation rate estimated: 21 Yes Texture Group: I ❑ If ❑ III O IV ❑
❑ No Estimated rate: 70 mpi @ 20"
7. Permeability Test Performed? ❑ No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
❑ Site Approved. Drainfield to be placed at 20 " depth at site desijnated an permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock-
3 ❑ Insufficient depth of suitable soil to seasonal water table-
4 ❑ Rates of absorption too slow.
5 ❑_ Insufficient area of suitable soil for drainfreld and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pagges if necessary
Aaaftlonal Notes: IWA Reserve
Address: Stockton Creek
PI
P2
P3
P4
PS
Seltzel Soil Eval Date: 09/09/21
GPm BultinQ Drainfield: 17-1
Ap
0-10
many roots
Bt
10-27 5YR 5/6 clay loam, strong medmoLsubangtdarblocky
structure, friable, common roots
5YR 5/6 light silty clay loam, weak medium suhangular
BCt
27-35 blocky structure, friable, few roots, common IOYR 6/8
III
parent material mottles
5YR 5/8 and IOYR 6/8 silt loam, structureless-massive,
C
38-70 friable, few roots, common IOYR 8/1 parent material
III
mottles
Ap
0-8 1 OYR 413 loam, weak inedima granular structure, friable,
II
many roots
Bt
8-24 SYR 5/6 clay loam, strong medium subangular blocky
structure, friable, common roots
5YR 5/6 light silty clay loam, weak medium subangular
BCt
24-34 blocky structure, friable, few roots, common 1 OYR 6/8
III
parent material mottles
SYR 3/8 and IOYR 6/8 silt loam, stxmckazebess-masffive,
C
34-70 friable, few roots, common IOYR 811 parent material
III
mottles
Ap
lOYR 4/3 loam, weak medium granular structure, friable,
0 11
II
many roots
Bt
11-29 M 4/6 clay loam, strong medium snbangular blocky
structure, friable, common roots
5YR 5/6 fight clay loam, weak medium subangular
BCt
29-40 blocky structure, friable, few roots, common 10YR 6/8
III
parent material mottles
5YR 5/8 and 10YR 6/8 light silty Gay loam, structureless-
C
10-70 massive, friable, few roots, common IOYR 8/1 parent
III
material mottles
Ap
IOYR 4/3 loam, weak medium gramtiar structi e, friable,
0-8
many roots
Bt
9-30 BYR 5/6 clay loam, strong medium subangular blocky
III
structure, friable, common roots
8YR 8/8 and IOYR 6/8 silt loam, structureless-massive,
C
30-60 friable, few roots, common IQYR 8/1 parent material
III
mottles
A p
0-10 I OYR 413loam, weak medium granular structure, friable,
Ii
many roots
Bt
10-26 5YR 6/6 Gay loam, Btrong medium subangular blocky
Ul
structure, friable, common roots
5YR 8/8 and 10YR 6/8 silt loam, structureless-massive,
C
28-62 friable, few roots, common 1 OYR 8/1 parent material
III
mottles
Address: Stockton Creek
Pi
P2
P3
P4
P5
h 6'� to
Heltael Soil Eval Date: 09/10/21
Consultiaa Draiatteld: 17-2
Ap.�. �,. o.... o..,, ..�.....o.....,.. s.a...... .... lA
friable, many roots
Bt 9-2$ 8YR 6/6 clay loam, strong mediasubanga}arblocky M
structure, friable, commum mots; 5% rabbles
BCt
W-32 SYR 6/6 and IOYR 6/6 light silty clay loam, weak medium
III
subangular blocky structure, hiabla, few roots, 3%. cobbles
C
32-58 SYR 3/6 and IOYR 6/8 silt loam, stxuctureless-massive,
IA
friable, few roots
Ap
IOYR 4/3 sill loam, weak medium granular structure,
IA
friable, many roots
Bt
SYR 4/6 light clay loam, moderate medium subangular
&25
blocky structure, friable, common roots
SYR 6/6 and 7.5YR 6/8 light silty clay loam, weak medium
BCt
25-34 subangular blocky structure, friable, few roots, common
IA
IOYR 6/6 parent material mottles
C
34-60 IOYR 6/6 and 7,5YR 5/6 silt loam, massive,
III
friable, few roots
Ap
0-7 IOYR 4/3 silt loam, weak medium granular structure,
III
friable, many roots
Bt
7-20 7.5YR 4/6 silty clay loam, moderate medium subangular
M
blocky structure, friable, common mots
7.5YR 6/6 and 10YR 6/8 light silty clay loam, weak medium
BCt
20-27 subangular blocky struchtre, friable, few roots, common
III
I OYR 916 parent material mottles
C
27-60 IOYR 6/6 and T.SYR 5/6 sift loam, siructureless-massive,
III
friable, few roots
A p
0-8 IOYR 4/3 silt loam, weak medium granular structure,
AI
friable, many roots
Bt
T.SYR 4/6 silty clay loam, moderemedium edium subaaguhm
&20
blocky structure, friable, common mats
7.SYR 5/6 and lOYR 6/8 light silty clay loam, weak medium
BCt
20-27 subangular blocky structure, friable, few roots, common
III
IOYR 6/6 parent material mottles
C
27-60 10YR 6/6 and MYR 8/6 silt loam, stxuctureless-massive,
III
friable, few roots
Cr
80-82 fractured schist
Ap
0 8 IOYR 4/3 sift loam, weak medium granular structure,
III
friable, many roots
T.5YR 4/6 silty clay loam, moderate medium subangular
Bt
8 21 blocky structure, friable, common roots
7.SYR 5/6 and IOYR 6/8 light silty clay loam, weak medium
BCt
21-34 subangular blocky structure, friable, few roots, common
AI
IOYR 6/6 parent material mottles
C
34-49 10YR 7/6 and 7.SYR 618 silt loam, structurelsss-massive,
IA
friable, few roots
Cr
48-33 fractured schist
Heltrel Soil Consulting
Page � of �O
Abbreviated Design -Conventional Gravel -less
Site 17-1 Albemarle County PRIMARY
A.
a. Estimated percolation rate. (minutess perinch) _
b. Recommended trench bottom. finches)
65
24
c. Depth to impervious strata/ or water tables or limit of evaluation.
inches
70
70
70
d. Minimum separation distance required. inches
16
16
24
e. Separation distances in inches provided in design.
46
46
46
f. Sloe (percentage)
11
�19.5
g. Minimum trench bottom due to slope. Cinches _
h. Is the sloe greater than orequal to 10%?
Yes
i. If Ai is Yes, does 24 inches or greater to rocklimpervious strata exist below
Ab?
you
j. If yes to Aj, add 1 ft. to the minimum center -to -center spacing beginning at 200h
slope and continue for each 10% slope increase above 20%. If no to fy, add 1 ft. to the
minimum center -to -center spacing beginning at 10% slope and continue foreach 10%
slope increase above 10%. (Report the value, in feet, of the increase in oenber4o-Gnter
spacing above the minimum).
0
B.
a.Trench bottomsquare feet required per bedroom Table 5.4
496
b. Trench bottomsquare feet required for Gravel -less with 25% reduction.
372
C.
Ia. Number of bedrooms.
b. Gallons per da in design
a. Length of trench. feet
5
750
D.
so
b. Length of available area. feet
80
E.
Width of trench. feet
3
F.
Number of trenches.
9
G.
Center-to-centerspacing. feet
9
H.
Ia. Width required. (feet
75
b. Width of available area. feet
64
i.
Trench bottomsquare footage required.
1860
J.
Trench bottomsquare footage in design.
2160
K.
Is a reserve area required? Yes
x
INO
a. Percentrequired?
IW/e
b. Percent available:
100•/0
Notes: *See attached abbreviated design form for reserve'
Heltzel Soil Consulting, LLC
Page / of CQ
Abbreviated Design - TU Effluent with Trenches
Site 17-2 Albemarle County RESERVE
A.
a. Estimated percolation rate. minutesper inch
70_
_ _
b. Recommended trench bottom. inches
20
49 s0 s0
c. Depth to impervious strata/ or water table/ or limit of evaluation.
inches
d. Minimum separation distance required. inches
18
12
24
e. Separation distances in inches provided in design.
29
40
40
f. Sloe (percentage)
Minimum trench bottom due to sloe _ inches)
9
10.5
h. Is the sloe greater than orequal to 10%?
No
i. If Ai is Yes, does 24 inches or greater to rockfimpervious strata exist below
Ab?
Yes
j. If yes to Aj, add 1 ft to the minimum center -to -center spacing beginning at 20%
slope and continue for each 10% slope increase above 20%. If no to A), add 1 ft- to
the minimum center -to -center spacing beginning at 10% slope and continue for each
10% slope increase above 10%. (Report the value, in feet, of the increase in cenber-ro spacing above the minimum).
0
B
a.Design Type?
TU
b.Trench bottomsquare feet required loading rate, gpdMt2
O.s4
5
a. Number of bedrooms.
c.
b. Gallons per day in design
750
D.
a. Length of trench. feet
75
b. Len th of available area. (feet)
75
E.
Width of trench. feet
s
5
F.
Number of trenches.
G.
Center-to-centerspacing. feet —
9
H.
a. Width required. feet
48
b. Width of available area. feet
48
1.
Trench bottomsquare footage required.
1172
J.
Trench bottomsquare footage in design.
1350
X J No
K.
a. Is a reserve area required? Yes
b. Percent required
100%
c. Percent available
1 100%
Notes:
EZflow 12O3H - GEO
COVERNATIVE BACKFILL
ESTABLISH 6" MIN.
COVERVEGETATIVE � OR - •.
�I 1�t t gilt .� 1.1,1 I, ►,t 1,.it it ll'►i1 -
�►c11•.
FABRICFILTER
w
12" EZifow
BUNDLE (TYP.)
36" MIN.
TRENCH
WIDTH
NOTE:
PRODUCT CONFIGURATION AND INSTALLATION
DEPTH MUST COMPLY WITH APPLICABLE
REGULATORY REQUIREMENTS.
�}-4" PERFORATED
I PIPE
MAEZfZow°
NFIlTR11TOR SYMMS INC.
a Bu�Mss Park "M S%U kGT "S9T
poo) alrw3e
EZII"w 1203H - GEO
Or EMS w oow7 '
cwrm¢ue "nsaaN. 0FH I ""t 1 "It
Heltzel Soil
1412 SaumsvNle Road, Maumftwn, VA 22644
LLC
SITE 17-1 & 17-2 SKETCH
TM # 69-19F
ALBEMARLE COUNTY, VA
1 J P5
RESERVE
\ �4 ;3 P:
\ SM 17-2
39' >�--
'P4 P510
PRIMARY
WE 17-1 — o0
P3-
00 f..+
PZ p� o
917
140t
Page Q or 10
T.M.69
REVISED
4.63
October 20, 2022 50' 100' 150,
DRAWN BY: CSH
Heltzel Soil Consulting, LLC
1412 Saums,419 Road, Maurertown, VA 22644
DRAINFIELD LOCATION SKETCH
TM # 69-19F
ALBEMARLE COUNTY, VA
PRIMARY
SOM CI-
'CP&l
253 218'�
- - - LL AREA �O
6
03'
L \
October 22, 2022
DRAWN BY: CSH
T.M.69-19F
REVISED LOT 5
4.63 ACRES
SWELL #10
Page , D of 16
160,
(I�X '
21 100-w
WII,L AR
I
WELL #22 I
T.M.69-19E
REVISED LOT 4
A G r) A (`DCC ..R.'L
41T
o. Bo' ISO, too'
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
LOT 6
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
T.M.69-6M
REVISED LOT 7
E.C.ACKERMAN TRUST
D.B.4733-23
D.B.4733-20 & 21 PLAT
D.B.4456-444
D.B.3530-234 PLAT
STATE ROUTE 803
(30-PRESCRIPTIVE EASEMENT)
GOODLOE LANE
T.M.69-6G
LOT 1
FRANK DONLEY &
CARLA DONLEY
D.B.3380-82,
85 & 86 PLAT
POND
VDH �
MONUMENT
FOUND
VDH MONUMENT FOUND
PROPOS
STOCKTON CREEK
1t
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
(30-PRESCRIPTIVE EASEMENT)
EXISTIN
STOCKTON CREEK
Page I of 3
VIRGINIA Albemarle County Health Department
1138 Rose Hill Drive
DEPARTMENT Charlottesville, VA 22903
V/DHOF HEALTH (434) 972-6219 Voice
Protecting You and Your Environment (434) 972-4310 Fax
Sewaee Disposal Certification Letter Annroval
December 8, 2022 APPROVED
Stockton Creek, LLC
C/O Alan Taylor
455 Second Street SE, #201
Charlottesville. VA 22902
RE: Tax Map: 69-19F (Site 18-1)
HDID: 101-22-0404
Important Note: Certification Letter Approval for Site DF 18-1
Dear Alan Taylor,
This Certification Letter is issued in lieu of a sewage disposal system construction
permit in accordance with §32.1-163, et seq., of the Code of Virginia. The Board of Health
hereby recognizes that the soil and site conditions acknowledged by this correspondence, and
documented by additional records on file at the local health department, are suitable for the
installation of an onsite sewage disposal system. The attached plat shows the approved area for
the sewage disposal system. This letter is valid until a permit for construction is issued and the
system is installed, inspected and approved. This letter is void if there is any substantial physical
change in the soil or site conditions where the sewage disposal system is to be located.
The application for a certification letter was submitted pursuant to § 32.1-163.5 of the
Code of Kir ginia which requires the Health Department to accept private soil evaluations and
designs from an Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation
with an OSE for residential development. The site for an individual onsite sewage system was
certified as being in compliance with the Board of health's regulations by: Chris Heltzel,
AOSE License 1940001460. This letter is issued in reliance upon that certification.
A permit to construct the sewage disposal system must be issued before construction of
the system. If the property owner (current or future) applies for a construction permit within 18
months of the date of this letter, the application fee paid for this letter shall be applied to any
state fees for a permit to construct a sewage disposal system. After 18 months, the applicant is
responsible for paying all state fees for a permit application.
Tax Map: 69-19F (Site 18-1)
HDID: 101-22-0404
Page 2 of 2
This letter, and accompanying plat of survey showing the specific location of the sewage
disposal system area and well area (if applicable), may be recorded in the land records by the
clerk of the circuit court in the jurisdiction where all or part of the site or proposed site of the
system is to be located. The site shown on the plat is specific and must not be disturbed or
encroached upon by any construction. To do so voids this letter. Upon the sale or transfer of the
land that is the subject of this letter, the letter shall be transferred with the title to the property.
Future owners are advised to review the plat for the location of the onsite sewage disposal area to
make sure their building plans do not interfere with the area. If they have any questions
regarding the location of the area, they should contact the local health department for assistance.
The area evaluated, and certified by this letter, is suitable to accommodate a 3 bedroom
house using a system design of 450 gallons per day. The property will be served by a Private
water supply as shown on the attached plat. Owners are further advised that when connection to
a public water system is proposed and the public water system has reached its permitted capacity,
a permit for construction may not be issued until such time that a connection is approved and
available for use.
This letter is an assurance that a sewage disposal system construction permit will be
issued (provided there have been no substantial physical changes in the soil or site conditions
where the system would be located); however, it is not a guarantee that a permit for a specific
type of system will be issued. The design of the sewage system will be determined at the time of
application for a building permit and sewage system construction permit. The design will be
based on the site and soil conditions certified by this letter, structure size and location, water well
location (final determination to be made at time of permit issuance), the regulations in effect at
the time.. and any off -site impacts that may have occurred since the date of the issuance of this
letter, In some cases, engineered plans may be required prior to issuance of the construction
permit. In accordance with § 32.1-164.1:1 of the Code of Virginia, owners are advised to apply
for a sewage disposal construction permit only when ready to begin construction.
This certification letter approval has been issued in accordance with applicable
regulations based on the information and materials provided at the time of application. There
may be other local, state, or federal laws or regulations that apply to the proposed construction of
this onsite sewage system. The owner is responsible at all times for complying with all
applicable local, state, and federal laws and -regulations. If you have any questions, please contact
me.
Issued by:
ue/i .."o
sh Kirtley
Environmental Health Technical Consultant
COMMONWEALTH OF VIRGINIA
Application for. E Sewage System
Owner. Stockton Creek LLC do Alan Taylor
❑ Water Supply
Mailing Address: 455 Second Street SE, # 201
Charlottesville, VA 22902
Agent: Stockton Creek LI C Uo Alan Taylor
Mailing Address: 465 2nd Street SE, Suite 201 Charlottesville, VA 22902
Site Address: TBD
Directions to Property:
Subdivision:
Tax Map:
Afton, VA 22920
Comer of Route 250 6 Route 161
DF
VDH USE CINI.
Health Dept 10# i i
Due Date: —
Phone: 512426 4728
Fax
Phone:
Phone: 434-MI-36 4
Email"—shnPin istrudionimnaeffinwitem
Lot:
Acreage: 4.63
sewage System -- -
of Approval: Applicants for new construction are advised to apply for a certification tetterto debarrnttte h ttre land is suitable fora sewage
n and to apply for a construction permit (valid for 18 months) only when ready to build.
59-19F
Section: Block:
Other Property Info:
R1 Certification Letter ❑ Construction Permit
sod Use:
Family Home (Number of Bedrooms)
(Describe):
tam O Yes
❑ No
3
Walk -Out Basement? Yes
❑ No
❑ Subdlvlson Approval ❑ Repair
Muftftmlly Home (Total # of Bedrooms)
Fbdures in Basement? ❑+ Yes
❑ No
Conditional Permit Desired? ❑ Yes 0 No If yes, what type of conditions are desired?
❑ Reduced Water Flow ❑ Limited Occupancy ❑ Intermittent or seasonal use ❑ Temporary Use (r yr. mapdmum)
Do you wish to apply for a betterment loan eligibility letter? ❑ Yaw- 21 No
"There Is a $60 fee for determination of elioibAity.
the water supply be ❑ Public or
If proposed, is this a replacement well?
within Sly of the well
this a private sector OSE/PE application?
Water Supply _ ---
Private Is the water supply ❑ 6dsting or B Proposed
❑ Yes R1 No If yes, will the old well be abandoned? ❑ Yes ❑ No
treated? ❑ Yes ❑ No
All Applicants
❑ Yes ❑ No
the property intended to serve as your (the owners) principal place of residence?
If yes, Is the OSE package attached? Q Yes
❑ No
❑ Yes Q No
to oroer for vurt Cr process your application for a sewage system, you must attach a plat of the property and a she sketch. For water supplies, a
plat of the property Is recommenced and a site sketch is required. The site sketch should show your property lines, actual and/or proposed
bulidings, and the desired location of your welt and/or sewage system. When the site evaluation is Conducted, the property Ines, building location
and the prop" hsewage sites must be dearly marked and the property suflciently visible to see t � topography.
1 give peififsstoh'io tlhe of Health to enter onto the property described Wring normal business hours for the purpose of
proceau h its appdce5on and gps&Y assurance checks of evafuatlons and designs certified by a private sector Onslte Soli Evaluator
or Pr� a�onal Engtnoer nets ntsthe sewn a disposal system and/or private water supply has been constructed and approved.
Ctltu�, �• ..--
iII=.L:fZLL 9
Lfc No.1940001460
,r
atlae'@flOwn t >" Date
rC�h;�ti{ tsr.%M purer d%%W.+ MUM Mkrt�rmu
XWLUKjkft
F4e5 HDID#
Dow Rs Dwr Dae
n. a
s...p.r d
❑ Construction Permit ❑ Repair
Permit
rrooertv Location:
1 Address:
or Tax Map #:
Bred by:
Name:
Name:
OSE(PE Report For:
❑ Voluntary Upgrade ❑ Certification
Permit Letter
Section: Subdivision: DF 19-1
69-19F Health Dept. ID #:
Longitude:
Page oof _%
❑ Subdivision Approval
City, State, Zip: Afyon, VA 22920
Stockton Creek LLC Wo Alan Taylor
455 Second Sfreef SE, # 201 _ ChadotfesH/h, VA 22902
Chris Heltrel License # 1940-001460
PO Box 554, Woodstock, VA 228"
Ucense #
Date of Report: 10/2Z2022
COntentslindex of this report:
1. Cover Sheet
11 Soil Evaluation
Statement
Date of Revision ft
Date of Revision #2:
6. Site Sketch
7. DralnHe/d Location & Sanitary Survey
I hereby certify that the evaluations and/or designs contain herein were conducted in accordance with the applicable provisions of Ore
Sewage Handling & Disposal Regulations tl2VAC5-610), the Private Well Regulations (12VAC"30), the Regulations fnrANamaWe Onsft
Systems (12VAC5-e13) and all other applicable taws, regulations, and policies implemented by the Virginia Department of Health. )further
certify that I currently posses any professional license required by the laws and regulations of the Commonwealth that have been duty issued
by the applicable agency charged with ficensure to perform the work contained herein. The potential for both conventional and alternative
onsite sewage systems has been discussed with the ownedWplicent.
O The work
recommend that a:
� LicNo.C9d0001460
Signature:
has been conducted under an exemplion to the practice of engineedng, speffmay the
54.1-402A.11
❑ Subdivision Approval be: 0 Issued
Repair Permit ❑ Voluntary Upgrade ❑ Denied
Date: \o t ZZ( 2Z
page 'L of I
SOIL SUMMARY REPORT
GENERAL
Date: 9/1012021 Submitted to: Albemarle County Health Department
Owner: Stockton Creek LLC c/o Alan Tavlor Telephone Number: 512-426.4728
Address: 455 Second Street SE, * 201 Charlottesville, VA 22902
(Agent: Stockton Creek LLC rlo Alan Taytor Address: 455 2nd Street SE, Sutter 201 Charlottesville, VA 229M
(Property Location: TBD Tax Map/GPIN: 69-19F
Subdivision: Blk/Sec: Site: 18-1
1. Position in Landscape Satisfactory: El Yes ❑ No
Describe: Convex Upland Sidestcpe
2. Slope: 11-13 %
3. Depth to Rock or Impervious Strata: Max. 55"+ Min. 44" None ❑
4. Depth to seasonal water table (gray mottling or gray color): Not Observed Yes ❑
5. Free Water Present? Q No ❑ Yes Range: inches
6. Soil Percolation rate estimated: ❑ Yes Texture Group: 1 ❑ II ❑ III 0 IV ❑
❑ No Estimated rate: 70 mpi @ 18"
7. Permeability Test Performed? 0 No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
(] Site Approved. Drainfield to be placed at 18 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of sutbable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ Insufficient area of suitable soil for drainfield andtor reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages it necessary)
Additional Notes:
Page of?
Heltzel Soil Consulting
Property Address: TBD Site: 18-1
Tax Map Number: 69-19F Date of Evaluation: 9/10/2021
Profile
Horizon
Depth
Description
Texture
class
P1
A
0_8
10YR 4/3 silt loam, weak fine subangular blocky
III
structure, friable, many roots
7.SYR 5/4 silty clay loam, moderate coarse
Bt
8-29
ill
subangular blocky structure, friable, common roots
7.5YR 5/6 light silty clay loam, weak coarse
BCt
29-36
subangular blocky structure, friable, common roots,
III
few IOYR 7/6 Ilthochromic mottles
C
36-69
7.SYR 5/6 & 10YR 6/6 silt loam, friable, few roots
III
P2
A
0 7
10YR 4/3 silt loam, weak fine subangular blocky
III
structure, friable, many roots
Bt
7-23
SYR 5/4 clay loam, moderate medium subangular
III
blocky structure, friable, common roots
SYR 5/6 silty clay loam, weak coarse subangular
BCt
23-32
blocky structure, friable, common roots, few 10YR
III
7/6lithochromic mottles
C
32-55
7.5YR 6/8 & SYR 5/6 silt loam, friable, few roots
III
P3
A
0-8
10YR 4/3 silt loam, weak fine subangular blocky
III
structure, friable, many roots
Bt
8-22
SYR 5/4 silty clay loam, moderate medium
III
subangular blocky structure, friable, common roots
7.5YR 5/6 light silty clay loam, weak coarse
BCt
22-30
subangular blocky structure, friable, common roots,
III
few IOYR 7/6 lithochromic mottles
C
30-50
7.SYR 5/6 & IOYR 6/6 silt loam, friable, few roots
IOYR 4/3 silt loam, weak fine subangular blocky
III
P4
A
0-7
III
structure, friable, many roots
Bt
7-30
7.SYR 5/6 silty clay loam., moderate fine subangular
III
blocky structure, friable, common roots
C
3D-42
SYR 5/6 & 10YR 5/6 silt loam, friable, few roots, 10%
Ilf
channers
Fractured bedrock, pervious, few roots
Cr
42-45
Page y of I
P5
A
0-8
10YR 4/3 silt loam, weak fine subangular blocky
III
structure, friable, many roots
Bt
8-31
_
7.SYR 5/6 silty clay loam, moderate fine subangular
III
blocky structure, friable, common roots
C
31-55
5YR 5/6 & 10YR 5/6 silt loam, friable, few roots, 10%
III
channers
Cr
55-58
Fractured bedrock pervious, few roots
P6
A
0-7
10YR 4/3 silt loam, weak fine subangular blocky
Ili
structure, friable, many roots
Bt
7 28
7.5YR 5/6 silty clay loam, moderate fine subangular
III
blocky structure, friable, common roots
C
28 52
5YR 5/6 & 10YR 5/6 silt loam, friable, few roots, 10%
II[
channers
Cr
52-55
Fractured bedrock, pervious, few roots
Heitzel Soil Consulting, LLC
Page S of -1
Abbreviated Design - TL3 Effluent with Trenches
Site 18-1 Albemarle County
70
to impervious strata/ or water table/ or limit of evaluation.
mcnes q4 5U 5;
d. Minimum separation distance required. inches 18 12 24
e. Separation distances in inches provided in design. 2s 37 37
f. Sloe (percentage) 13
Minimum trench bottom due to slope . (inches) 12.5
T—
h. Is the sloe reater than orequal to 10%?
Yes
i. If Ai is Yes, does 24 inches or greater to rock/impervious strata exist below
Ab?
Yes
j. If yes to Aj, add 1 ft to the minimum center-tocenter spacing beginning at 20%
slope and continue for each 10% slope increase above 20%. If no to Aj, add 1 it to
the minimum center -to -center spacing beginning at 10% slope and continue for each
10% slope increase above 10%. (Report the value, in feet, of the increase in center -to -
center spacing above the minimum).
0
®
a.Design Type?
TL3
b.Trench bottomsquare feet required loading rate, gpdM
0.64
c.
a. Number of bedrooms.
3
b. Gallons per day in design
450
D. Ia.
Length of trench. feet
so
b. Length of available area. feet
60
E.
Width of trench. feet
3
F.
Number of trenches.
4
G.
Center-to-centerspacing. feet
s
H.
a. Width required. feet
30
b. Width of available area. feet
64
I.
Trench bottomsquare footage required.
703
J. ITrench
bottomsquare footage in design.
720
K.
a. Is a reserve area required? Yes
X
No
b. Percent required
100%
c. Percent available
100%
Notes:
Heltzel Soil Consulting, LLC
102 Sauffwft Road, Maumdown, VA 22644
SITE 18-1 SKETCH
TM # 69-19F
ALBEMARLE COUNTY, VA
T.M.69-19F-
REVISED LOT 5
4.63 ACRES
29' -ice
•P6
PS
WELL #10 ' 2�'
oP3
SrFE 1 /
P4•
IHB Pi
ti
WELL
�o
o /
Page �- of 7
100.00' —
1
October 20, 2022
DRAWN BY: CSH
Heltzel Soil Consulting, LLC
1412 Saurnsville Road, Msumftwn, VA 22844
z
w
LL.
RESERVE
DRAINFIELD LOCATION SKETCH
TM # 69-19F
ALBEMARLE COUNTY, VA
MUMMY
SM7.1
T.M.69-19F
REVISED LOT 5
4.63 ACRES
SWELL #10
.LL AREA Cb6\
ti
100.w
C
W L AREA WELL
0
October 22, 2022
DRAWN BY: CSH
Page -% of 7
21
#22
T.M.69-19E
REVISED LOT 4
n c� n r% o Cc ,.4
41T
o• ao• aso• eso•
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
LOT 6
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
T.M.69-6M
REVISED LOT 7
E.C.ACKERMAN TRUST
D.B.4733-23
D.B.4733-20 & 21 PLAT
D.B.4456-444
D.B.3530-234 PLAT
PROPOS
STOCKTON CREEK
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
MART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
(30-PRESCRIPTIVE EASEMENT)
EXISTIN
STOCKTON CREEK
VIDHOFVIRGINIA
DEPARENT
HEALTH
Protecting You and Your Environment
Sewaee Disposal Certification Letter Approval
November 28, 2022
Page I of 3
Albemarle County Health Department
1138 Rose Hill Drive
Charlottesville, VA 22903
(434) 972-6219 Voice
(434) 972-43 10 Fax
Stockton Creek, LLC APPROVED
CIO Alan Taylor
455 Second Street SE, #201
Charlottesville, VA 22902
RE: Tax Map: 69-19H (Site DF 10)
HDID: 101-22-0400
Important Note: Certification Letter Approval for Site DF 10
Dear Alan Taylor,
This Certification Letter is issued in lieu of a sewage disposal system construction
permit in accordance with §32.1-163, et seq., of the Code of Virginia. The Board of Health
hereby recognizes that the soil and site conditions acknowledged by this correspondence, and
documented by additional records on file at the local health department, are suitable for the
installation of an onsite sewage disposal system. The attached plat shows the approved area for
the sewage disposal system. This letter is valid until a permit for construction is issued and the
system is installed, inspected and approved. This letter is void if there is any substantial physical
change in the soil or site conditions where the sewage disposal system is to be located.
The application for a certification letter was submitted pursuant to § 32.1-163.5 of the
Code of Virginia which requires the Health Department to accept private soil evaluations and
designs from an Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation
with an OSE for residential development. The site for an individual onsite sewage system was
certified as being in compliance with the Board of Health's regulations by: Chris Heltzel,
AOSE License 1940001460. This letter is issued in reliance upon that certification.
A permit to construct the sewage disposal system must be issued before construction of
the system. If the property owner (current or future) applies for a construction permit within 18
months of the date of this letter, the application fee paid for this letter shall be applied to any
state fees for a permit to construct a sewage disposal system. After 18 months, the applicant is
responsible for paying all state fees for a permit application.
Tax Map: 69-19H (Site DF 10)
HDID: 101-22-0400
Page 2 of 2
This letter, and accompanying plat of survey showing the specific location of the sewage
disposal system area and well area (if applicable), may be recorded in the land records by the
clerk of the circuit court in the jurisdiction where all or part of the site or proposed site of the
system is to be located. The site shown on the plat is specific and must not be disturbed or
encroached upon by any construction. To do so voids this letter. Upon the sale or transfer of the
land that is the subject of this letter, the letter shall be transferred with the title to the property.
Future owners are advised to review the plat for the location of the onsite sewage disposal area to
make sure their building plans do not interfere with the area. If they have any questions
regarding the location of the area, they should contact the local health department for assistance.
The area evaluated, and certified by this letter, is suitable to accommodate a 5 bedroom
house using a system design of 750 gallons per day. The property will be served by a Private
water supply as shown on the attached plat. Owners are further advised that when connection to
a public water system is proposed and the public water system has reached its permitted capacity,
a permit for construction may not be issued until such time that a connection is approved and
available for use.
This letter is an assurance that a sewage disposal system construction permit will be
issued (provided there have been no substantial physical changes in the soil or site conditions
where the system would be located); however, it is not a guarantee that a permit for a specific
type of system will be issued. The design of the sewage system will be determined at the time of
application for a building permit and sewage system construction permit. The design will be
based on the site and soil conditions certified by this letter, structure size and location, water well
location (final determination to be made at time of permit issuance), the regulations in effect at
the time, and any off -site impacts that may have occurred since the date of the issuance of this
letter. In some cases, engineered plans may be required prior to issuance of the construction
permit. In accordance with § 32.1-164.1:1 of the Code of Virginia, owners are advised to apply
for a sewage disposal construction permit only when ready to begin construction.
This certification letter approval has been issued in accordance with applicable
regulations based on the information and materials provided at the time of application. There
may be other local, state, or federal laws or regulations that apply to the proposed construction of
this onsite sewage system. The owner is responsible at all times for complying with all
applicable local, state, and federal laws and regulations. If you have any questions, please contact
me.
Issued by:
1 00000-
#4osh Kirtley
Environmental Health Technical Consultant
COMMONWEALTH OF VIRGINIA
Application for. ❑ Sewage System ❑ Water Supply
Owner. Stockton Crook LLC do Alan Taylor
Mailing Address: 455 Second Street SE, # 201
Charlottesville, VA 22902
Agent: Stockton Creek LLC c/o Alan Taylor
Mailing Address: 456 2nd Street BE, Suite 201 Charlottesville, VA 22902
Site Address: T9D
Afton, VA 22920
Directions to Property:
Comer of Route 250 8 Route f5f
Phone:
Fax:
Phone:
Phone:
Fax:
VDH USE ONLY
Health Dept ID# iCl ?-O' -Gv
Due Date:
512r4264726
434-9813634
Email: almpsor@atle.mnstmeuonmanagemem.eam
Subdivision: DF 10 Section: Block: Lot:
Tax Map: 69-19H Other Property Info: Acreage: 11.03
Sewage System
Type of Approval: Applicants for new construction are advised to apply for a certification letter to determine If the land Is suitable for a sewage
system and to apply for a construction permit (valid far 18 months) only when ready to build.
El Certification Letter ❑ Construction Permit ❑ Subdivison Approval ❑ Repair
Proposed Use:
Single Family Home (Number of Bedrooms) 5 Multifamily Home (Total # of Bedrooms)
Other (Describe):
Basement Yes Walk -Out Basement? ID Yes Fixtures In Basement? 0 Yes
❑ No ❑ No ❑ No
Conditional Permit Desired? ❑ Yes 0 No If yes, what type of conditions are desired?
❑ Reduced Water Flow ❑ Limited Occupancy ❑ Intermittent or seasonal use ❑ Temporary Use (1 yr. maximum)
Do you wish to apply for a betterment loan eligibility letter ❑ Yes" ED No
"There Is a $50 fee for determination of eilalbillty.
Water Supply
Will the water supply be ❑ Public or [.] Private Is the water supply ❑ Existing or [D Proposed
If proposed., is this a replacement well? ❑ Yes 2 No If yes, will the old well be abandoned? ❑ Yes ❑ No
Will any buildings within 50' of the well be termite treated? ❑ Yes 0 No
All Applicants
Is this a private sector OSE/PE application? ❑� Yes ❑ No If yes, is the OSE package attached? Yes
El No
Is the property intended to serve as your (the owners) principal place of residence? ❑ Yes M No
In order for VDH of process your application for a sewage system, you must attach a plat of the property and a site sketch. For water supplies, a
plat of the property Is recommenced and a site sketch is required. The site sketch should show your property lines, actual and/or proposed
buildings, and the desired location of your well and/or sewage system. When the site evaluation is conducted, the property lines, building location
and the proposed well and sewage ettes must be dearly marked and the property sufficiently visible to see the topography.
I give penml
hgppl -
artment of Health to enter onto the property described during normal business hours for the purpose of
prooessin
ication a I4p
rm quality assurance checks of evaluations and designs certified by a private sector Onsite Sal Evaluator
or Prom
Engineer as n
-
J9
ntil the sewage dispos system and/or private water supply has been constructed and approved.
OAC
�R?STOPtt£2s.
�l
Signat T
e
Date
x�arr.{allot Dina Bsarae:,�,,,,,,�„Dot7o��„'
1faeS 11QED ix P>serodd aoa it
AtfW72Vfft R &W# _ Reoet#t tl
Page of b
❑ Construction Permit ❑ Repair
Permit
OSEIPE Report For:
❑ Voluntary Upgrade Certification
Permit Letter
❑ Subdivision Approval
Property Location:
911 Address: TBD City, State, Zip: Alton VA 22920
Lot: Section: Subdivision: DF 10
GPIN or Tax Map #: 69-19H Health Dept. ID #:
Latitude: Longitude:
Owner:
Name: Stockton Creek LLC c!o Alan Taylor
Address: 455 Second Sheet SE, # 201 ChadottesW/le, VA 22902
Prepared by:
OSE Name: Chris Waal _ License # 1940-001460
Address: PO Box 554, Woodstock, VA 22064
PE Name: License #
Address:
Date of Report: 10{2&2022 Date of Revision #1:
Date of Revision #2:
Contents/index of this report:
1. Cover Sheet 5. Site Sketch
2. Soil Evaluation 6. Dralrefield Location & Sarthary Survey
3. Profiles
4. Abbreviated Desl n
Certification Statement
I hereby certify that the evaluations and/or designs contain herein were conducted in accordance with the applicable provisions of the
Sewage Handling & Disposal Regulations (12VAC5-610), the Private Well Regulations (12VAC5-630), the Regulations for Alternative Onske
Systems (12VAC5.613) and all other applicable laws, regulations, and policies implemented by the Virginia Department of Health. I further
certify that I currently posses any professional license required by the laws and regulations of the Commonwealth that have been duly issued
by the applicable agency charged with Ilcensure to perform the worK contained nerein. The potential for both conventional and aftemative
onsite sewage systems has been discussed with the owner/applicant.
n ttpp this cover page has been conducted under an exemption to the practice of engineering, specifically the
to Mrginia Section 54.1-402.A.I I
I recomm a: ❑ Construe& --Permit ❑ Subdivision Approval be: ❑� issued
C"RISW 1 tio�L iter ElRepjit Permit El Voluntary Upgrade El Denied
O HELTZEb \
is No-1940001460 r ` c7 rz net
OSE/PE S moire: r i�i�cj Date:
�'�ONSI'tBs°
The form Wntsins personal information subject to disclosure under the Freedom of Information Act Revised 12101114
Page 2 of
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 10/31/2022 Submitted to: Albemarle County Health Department
Owner: Stockton Creek LLC c/o Alan Taylor Telephone Number. 512-426-4728
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: Stockton Creek LLC do Alan Taylor Address: 455 end street SE, suite 201 Charlottesville. VA 22902
Property Location: TBD Tax Map/GPIN: 69-19H
Subdivision: Blk/Sec: Site: 10-1
1. Position in Landscape Satisfactory: 121 Yes ❑ No
Describe: Convex Upland Sideslope
2. Slope: 18-20 %
3. Depth to Rock or Impervious Strata: Max. 60"+ Min. 35" None ❑
4. Depth to seasonal water table (gray mottling or gray color): Not Observed ❑ Yes ❑
5. Free Water Present? 0 No ❑ Yes Range: inches
6. Soil Percolation rate estimated: I] Yes Texture Group: I ❑ it p III ❑ IV ❑
❑ No Estimated rate: 60 mpi @ 3"
7. Permeability Test Performed? 0 No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
1Z Site Approved. Drainfield to be placed at 3 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ Insufficient area of suitablesoilfor drainfield and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ other (Specify Below. Add additional pages if necessary)
Additional Notes:
Address: Stockton Creek
PI
P2
P3
P4
PS
P "7C'
Reltzel Soil Eval Date: 10/21/21
Consultina Dsainfield: 10-1
Ap
0-10 10YR 4/3 loam, weak medium granular structure, very
II
friable, many roots
Bt
10-20 7'3YR 5/8 heavy loam, weak medium subangular blocky
11
structure, friable, common roots
C
20-35 7.5YR 5/8 and lOYR 8/6 light loam, friable, few roots, 5%
II
channers
Cr
35-40 fractured bedrock, pervious
A p
0-6 1 OYR 4/3 loam, weak medium granular structure, very
II
friable, many roots
Bt
6_29 8YR 8/6 light clay loam, moderate medium subangular
blocky structure, friable, common roots
BCt
29-39 5YR 5/6 and 7.5YR 6/6 sandy clay loam, weak medium
II
subangular blocky structure, friable, common roots
C
39-60 2.5YR 5/6 and 7.5YR 6/6 light sandy clay loam, friable, few
II
roots
A
0-8 1 OYR 4/3 loam, weak medium granular structure, very
II
friable, many roots
Bt
B-21 5YR 5/6 light clay loam, moderate medium subangular
blocky structure, friable, common roots
BCt
21-30 5YR 6/6 and 7.6YR 6/6 sandy clay loam, weak medium
II
subangular blocky structure, friable, common roots
C
30-48 2.SYR 5/6 and 7.5YR 6/6 light sandy clay loam, friable, few
II
roots, 3% channers
Cr
45-80 fractured bedrock, pervious
A
0-5 10YR 4/3 loam, weak medium granular structure, very
friable, many roots
II
Bt
6-23 7.SYR 8/8 heavy loam, weak medium subangular blocky
II
structure, friable, common roots
C
23-38 7.8YR 5/6 and 7.5YR 6/8 light loam, friable, few roots, 5%
U
channers
Cr
38-42 fractured bedrock, pervious
A
0-6 1 OYR 4/3 loam, weak medium granular structure, very
friable, many roots
II
Bt
8-25 7.5YR 5/8 heavy loam, weak medium subangular blocky
II
structure, friable, common roots
C
25-45 7.8YR 8/6 and 7.5YR 6/8 light loam, friable, few roots, 5%
H
charmers
Cr
46-48 fractured bedrock, pervious
Heltael Soil Consulting, LLC Page �k of ('
Abbreviated Design -TL3 to Drip Disposal
Site 10-1 Albemarle County
A.
a. Estimated percolation rate. (minutes per inch)
60
b. Recommended drip tubing installation. (inches)
3
c. Depth to impervious strata/ or water table/ or limit of evaluation. (inches)
35
35
35
d. Minimum separation distance required. (inches)
1s
12
24
e. Separation distances in inches provided in design.
32
32
32
f. Slope (percentage)
20
g. Is the sloe greater than 10, 20 or 30%?
Yes
i. If Ag is Yes, does 24 inches or greater to rockfimpervious strata exist
below Ab?
Yea
B.
a.Design Type?
TL3
b.Soil Loading Rate, d/ftz
0.28
C.
a. Number of bedrooms.
5
b. Gallons per day in design
750
D.
a. Length of run. (feet)
75
b. Length of available area. (feet)
75
E.
Width of drip tubing. (inch)
1
F.
Number of runs.
20
G.
Center -to -center spacing. (feet)
2
H.
a. Width required, feet
39
b. Width of available area. (feet)
77
1. Ia.
Total square footage required
2679
b. Total square footage in design
2926
J.
a. Linear feet of drip tubing required
1339
b. Linear feet of drip tubing provided
1463
K.
a. Is a reserve area required? Yes
X
No
b. Percent required
100%
c. Percent available
100%
Notes: Design is same for RESERVE
Heltzel Soil Consulting, LLC
1412 Saumsville Road, Maurerlown, VA 22644
SITE 10-1 SKETCH
TM # 69-19H
ALBEMARLE COUNTY, VA
WELL AREA
STIR 2-2
T.M.69-19H
ILSM2-1 REVISED LOT 7
11.03+/- ACRES
761--,1
Pi
A_ P2.
SITE 10-I o0��
�Ps �v
. P4 0�06
1
October 24, 2022
DRAWN BY: CSH
Page 7 of (S
hm\'-�
WELL AREA
Heltzel Soil Consulting, LLC Page ( of
1412 SaumeAlle Road, Maurertown, VA 22644
616' 401' \
- M.w „u
T.M.69-19G
REVISED LOT 6 zs8,
2.63 ACRES I
1
235`
301'
PREMARY
6S11d
T.M.69-19F
REVISED LOT 5
4.63 ACRES
October 24, 2022
DRAWN BY- CS14
---- ..--
#12
T.M.69-19H
REVISED LOT 7
11.03+/- ACRES
oul Ls I m
WELL AREA 0.
00 \ N
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
LOT 6
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
T.M.69-6M
REVISED LOT 7
£.C.ACKERMAN TRUST
0.8.4733-23
D.B.4733-20 & 21 PLAT
D.B.4456-444
D.B.3530-234 PLAT
STATE ROUTE 803
(30'PRESCRIPTIVE EASEMENT)
GOODLOE LANE
T.M.69-6G
LOT 1
FRANK DONLEY &
CARLA DONLEY
D.B.3380-82,
85 & 86 PLAT
POND
VDH �
MONUMENT
FOUND
VDH MONUMENT FOUND
PROPOSH
STOCKTON CREEK S
i
C
TV
Heltzel Soil Consultinq, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
STUART TA) -OR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
POND
(30'PRESCRIPTIVE EASEMENT)
VDH
MONUMENT
FOUND
VDH MONUMENT FOUND
EXISTING
STOCKTON CREEK S
ST.RT.7°
oL0
::
..........................................
.........................................
..........................................
.........................................
T.M.69-19G
�/���/// REVSED LOT 8
2.63 ACRES
\\}
T.M.69-19F
REVISED LOT 5
4.63 ACRES
n-
7 DTM.899E
REVSED LOT 4
u
4.62 ACRE
J.
1
T.M.6r9n-
REVISED
7.70 AI
T.M.69-19D
REVSED LOT 3
4.56 ACRES
0.x)9
C
VDH
MONUMENT
FOUND
mi
RGINIA
V/DHOF HEALTH
Protecting You and Your Environment
Sewage Disposal Certification Letter Approval
November 28, 2022
Pagel of 3
Albemarle County Health Department
1138 Rose Hill Drive
Charlottesville, VA 22903
(434) 972-6219 Voice
(434) 972-4310 Fax
Stockton Creek, LLC /�A�
C/O Alan Taylor 4A
455 Second Street SE, 4201 /7r
Charlottesville, VA 2290240
RE: Tax Map: 69-19H (Site DF 2)
HDID: 101-22-0393
Important Note: Certification Letter Approval for Site DF 2
Dear Alan Taylor,
This Certification Letter is issued in lieu of a sewage disposal system construction
permit in accordance with §32.1-163, et seq., of the Code of Virginia. The Board of Health
hereby recognizes that the soil and site conditions acknowledged by this correspondence, and
documented by additional records on file at the local health department, are suitable for the
installation of an onsite sewage disposal system. The attached plat shows the approved area for
the sewage disposal system. This letter is valid until a permit for construction is issued and the
system is installed, inspected and approved. This letter is void if there is any substantial physical
change in the soil or site conditions where the sewage disposal system is to be located.
The application for a certification letter was submitted pursuant to § 32.1-163.5 of the
Code of Virginia which requires the Health Department to accept private soil evaluations and
designs from an Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation
with an OSE for residential development. The site for an individual onsite sewage system was
certified as being in compliance with the Board of Health's regulations by: Chris Heltzel,
AOSE License 1940001460. This letter is issued in reliance upon that certification.
A permit to construct the sewage disposal system must be issued before construction of
the system. If the property owner (current or future) applies for a construction permit within 18
months of the date of this letter, the application fee paid for this letter shall be applied to any
state fees for a permit to construct a sewage disposal system. After 18 months, the applicant is
responsible for paying all state fees for a permit application.
Tax Map: 69-19H (Site DF 2)
HDID:101-22-0393
Page 2 of 2
This letter, and accompanying plat of survey showing the specific location of the sewage
disposal system area and well area (if applicable), may be recorded in the land records by the
clerk of the circuit court in the jurisdiction where all or part of the site or proposed site of the
system is to be located. The site shown on the plat is specific and must not be disturbed or
encroached upon by any construction. To do so voids this letter. Upon the sale or transfer of the
land that is the subject of this letter, the letter shall be transferred with the title to the property.
Future owners are advised to review the plat for the location of the onsite sewage disposal area to
make sure their building plans do not interfere with the area. If they have any questions
regarding the location of the area, they should contact the local health department for assistance.
The area evaluated, and certified by this letter, is suitable to accommodate a 5 bedroom
house using a system design of 750 gallons per day. The property will be served by a Private
water supply as shown on the attached plat. Owners are further advised that when connection to
a public water system is proposed and the public water system has reached its permitted capacity,
a permit for construction may not be issued until such time that a connection is approved and
available for use.
This letter is an assurance that a sewage disposal system construction permit will be
issued (provided there have been no substantial physical changes in the soil or site conditions
where the system would be located); however, it is not a guarantee that a permit for a specific
type of system will be issued. The design of the sewage system will be determined at the time of
application for a building permit and sewage system construction permit. The design will be
based on the site and soil conditions certified by this letter, structure size and location, water well
location (final determination to be made at time of permit issuance), the regulations in effect at
the time, and any off -site impacts that may have occurred since the date of the issuance of this
letter. In some cases, engineered plans may be required prior to issuance of the construction
permit. In accordance with § 32.1-164.1:1 of the Code of Virginia, owners are advised to apply
for a sewage disposal construction permit only when ready to begin construction.
This certification letter approval has been issued in accordance with applicable
regulations based on the information and materials provided at the time of application. There
may be other local, state, or federal laws or regulations that apply to the proposed construction of
this onsite sewage system. The owner is responsible at all times for complying with all
applicable local, state, and federal laws and regulations. If you have any questions, please contact
me.
Issued by:
kfh Kirtley
vironmental Health Technical Consultant
COMMONWEALTH OF VIRGINIA
Application for: M Sewage System ❑ Water Supply
Owner: Stockton Creek LLC Go Alan Taylor
Mailing Address 455 Second Street SE, # 201
Charlottesville, VA 22902
Agent: Stockton Creek LLG c/o Alan Taylor
Mailing Address: 455 2nd Street SE, Suite 201 Charlottesville, VA 22902
Site Address: TBD
Afton. VA 22920
Directions to Property.
Subdivision:
Tax Mao:
-omer of Route 25D & Route 151
69-19H
Section:
Other Property Info:
VDH USE ONLY
Health Dept. ID#
Due Date:
Phone: 512-426-4728
Fax:
Phone:
Phone: 4344813634
Fex.
Email: simpson*euasconstruetlmmanagemsnt-wm
Block:
Lot:
Acreage: 11.03
Sewage Syetsm
Type of Approval: Applicants for new construction are advised to apply for a certification letter to determined the lend Is suitable for a sewage
system and to apply for a construction permit (valid for 18 months) only when ready to build.
0 Certification Letter ❑ Construction Permit ❑ Subdivison Approval ❑ Repair
Proposed Use:
Single Family Home (Number of Bedrooms) 5 Multifamily Home (Total # of Bedrooms)
Other (Describe):
Basement 21 Yes Walk -Out Basement? Yes Fixtures in Basement? [] Yes
❑ No ❑ No ❑ No
Conditional Permit Desired? ❑ Yes No If yes, what type of conditions are desired?
❑ Reduced Water Flow ❑ Limited Occupancy ❑ Intermittent or seasonal use ❑ Temporary Use (1 yr. maximum)
Do you wish to apply for a betterment loan eligibility letter? ❑ Yes" C] No
"There is a SW fee for determination of eligibility.
Water Supply
Will the water supply be ❑ Public or 0 Private Is the water supply ❑ Eldsting or ❑' Proposed
If proposed, is this a replacement well? ❑ Yes (] No If yes, will the old well be abandoned? ❑ Yes ❑ No
Will any buildings within Sty of the well be termite treated? ❑ Yes No
All Applicants
Is this a private sector OSEIPE application? [Z Yes ❑ No it yes, is the OSE package attached? Yes
❑ No
is the property intended to serve as your (the owners) principal place of residence? ❑ Yes 0 No
In order for VDH of process vour application for a sewage system, you must attach a plat of the property and a site sketch.
supplies, a
plat of the property is recommenced and a site sketch is required. The site sketch snouw snow your propeny nova, awuui anw v. p wt waaw
buildings, and the desired location of your well and/or sewage system. When the site evaluation Is conducted, the property lines, building location
and the prop a sties must be cleany marked and the property sufficiently visible to we the topography.
I give on to the Virginia em of Health to enter onto the property described during normal business hours for the purpose of
proce -...is application and to quality assurance checks of evaluations and designs certified by a private sector Onsite Soil Evaluator
or Pr on gQfslHtAricesrite the sewage disposal system anti/or private water supply has been constructed and approved.
O KELTZEL j
`) 194D`JDZ16rJ = �o(Z�Z �Z
L'ec No.
el Ur Date
nr��rrs+...mwa...r..wsda�iil�..:':. r..r..lwwn,tll r.UM s14M1
Vmtus.adv DaffiP.rared: Ora Dam
Fees FIAID ® Film" awt f
Peyp�typo'eLeck# eHDA Racctpte
Page L of 9__
❑ Construction Permit ❑ Repair
Permit
OSE/PE Report For.
❑ Voluntary upgrade Certification
Permit Letter
❑ Subdivision Approval
Property Location:
911 Address: TBD City, State, Zip: Afton VA 22920
Lot: Section: Subdivision: DF 2
GPIN or Tax Map #: 89-19H Health Dept. ID #
Latitude: Longitude:
Owner:
Name: Stockton Creek LLC c/o Alan Taylor
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Prepared by:
OSE Name: Cliffs Heltzel License # 1940-001460
Address: Po Box 554, Woodstock, VA 22884
PE Name: License #
Address:
Date of Report: 10,252022 Date of Revision #1:
Date of Revision #2:
Contentslindex of this report:
1. Cover Shea 8. She Sketch
2.3. Soli Evaluation 9. Drandlald Location & Sanitary Survey
". Profiles
6.7. Abbreviated Design
Certification Statement
I hereby certify that the evaluations and/or designs contain herein were conducted in accordance with the applicable provisions of the
Sewage Handling & Disposal Regulations (12VAC5-610), the Private Well Regulations (12VAC5-530), the Regulations for Alternative Onsife
Systems (12VAC,5-613) and all other applicable laws, regulations, and policies implemented by the Virginia Department of Health. I further
certify that I currently posses any professional license required by the laws and regulations of the Commonwealth that have been duly issued
by the applicable agency charged with licensure to perform the work contained herein. The potential for both conventional and alternative
onslte sewage systems has been discussed with the owner/applicant.
L7 The work i saver page has been conducted under an exemption to the practice of engineering, specifically the
exem Q dklattjx+r Section 54.1-402.A. I I
�1 t
I recommend that ��❑ Constntction � ❑ Subdivision Approval be: [] Issued
❑ ClS �ett ❑ Repair Permit ❑ Voluntary Upgrade ❑ Denied
pC ELTZEL
1.1cN0.1940t�14fi0
OSE/PE Signatu :� �� Date: `
��
aysrlss°%A
N
The form contains personal information subject to disclosure under the Freedom of Information Act. Revised 1 MV14
page Z of "A
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 10/27/2022 Submitted to: Albemarle County Health Department
Owner: Stockton Creek LLC C/o Alan Taylor Telephone Number. 512-426-4728
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: Stockton Creek LLC do Alan Taylor Address: 455 2nd street SE, Suite 201 Charlottesville, VA 22902
Property Location: TBD Tax Map/GPIN: 69-19H
Subdivision: Blk/Sec: Site: 2-1
1. Position in Landscape Satisfactory: 0 Yes ❑ No
Describe: Convex Upland Sideslo e
2. Slope: 5 %
3. Depth to Rock or Impervious Strata: Max. 60"+ Min. None 0
4. Depth to seasonal water table (gray mottling or gray color): Not Observed 0 Yes ❑
5. Free Water Present? Q No ❑ Yes Range: inches
6. Soil Percolation rate estimated: 2 Yes Texture Group: 1 ❑ 1121 III ❑ IV ❑
❑ No Estimated rate: 50 mpi @ 20"
7. Permeability Test Performed? O No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
0 Site Approved. Drainfield to be placed at 20 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ Insufficient area of suitable soil for drainfield and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages if necessary)
Additional Notes:
Page 3 of 1�
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 10/28/2021 Submitted to: Albemarle County Health Department
Owner: Stockton Creek LLC c/o Alan Taylor Telephone Number. 512-426-4728
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: Stockton Creek LLC do Alan Taylor Address: 455 2nd Street SE, Sufte 201 Charlottesville, VA 22902
Property Location: TBD Tax Map/GPIN: 69-19H
Subdivision: Blk/Sec: Site: 2-2
1. Position in Landscape Satisfactory: 1Z Yes ❑ No
Describe: Convex Upland Sideslope
2. Slope: 6 %
3. Depth to Rock or Impervious Strata: Max. 60+" Min. 50" None ❑
4. Depth to seasonal water table (gray mottling or gray color): Not Observed El Yes ❑
5. Free Water Present? a No ❑ Yes Range: inches
6. Soil Percolation rate estimated: Yes Texture Group: I ❑ II (] III ❑ IV ❑
❑ No Estimated rate: 70 mpi @ 0"
7. Permeability Test Performed? El No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
2 Site Approved. Drainffeld to be placed at 0 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ Insufficient area of suitable soil for drainfield and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages if necessary)
Additional Notes: 100% Reserve
Address: Stockton Creek
Pi
P2
P3
P4
PS
Heltzel Soil
b `toy -k
Eval Date:10/27/21
Drainfield: 2-1
1 OYR 3/2 loam, weak medium granular structure, very
II
A 0-8
friable, many roots
SYR 6/8 heavy sandy clay loam, moderate medium
II
Bt 8-36
subangular blocky structure, friable, common roots
C 36-60
SYR 6/6 sandy loam, friable, few roots
II
10YR 3/2 loam, weak medium granular structure, very
II
A 0-6
friable, many roots
SYR 5/8 heavy sandy clay loam, moderate medium
II
Bt 6-30
subangular blocky structure, friable, common roots
SYR 8/6 light sandy clay loam, weak medium subangular
II
Bc 30-40
blocky structure, friable, common roots
5YR 5/6 and 7.5YR 6/4 sandy loam, very friable, few roots,
II
C 40-60
3% channers
1 OYR 3/2 loam, weak medium granular structure, very
II
A 0-8
friable, many roots
SYR 618 heavy sandy clay loam, moderate medium
II
Bt 8-29
subangular blocky structure, friable, common roots
SYR 5/6 light sandy clay loam, weak medium subangular
II
BCt 29-47
blocky structure, friable, common roots
C 42-68
6YR 5/6 heavy sandy loam, friable, few roots
II
10YR 3/2 loam, weak medium granular structure, very
II
A 0-8
friable, many roots
SYR 5/8 heavy sandy clay loam, moderate medium
II
Bt 8-29
subangular blocky structure, friable, common roots
SYR 5/6 light sandy clay loam, weak medium subangular
II
BCt 29-47
blocky structure, friable, common roots
C 47-55
BYR 5/6 heavy sandy loam, friable, few roots
II
1 OYR 3/2 loam, weak medium granular structure, very
II
A 0-8
friable, many roots
SYR 5/8 heavy sandy clay loam, moderate medium
II
Bt 8-29
subangular blocky structure, friable, common roots
SYR 8/6 light sandy clay loam, weak medium subangular
II
BCt 29-47
blocky structure, friable, common roots
C 47-55
SYR 5/6 heavy sandy loam, friable, few roots
II
Address: Stockton Creek
PI
P2
P3
P4
P5
Reltzel Soil
Consulting
el 'Or
Eval Date: 10/28/21
Drai neld:2-2
1 OYR 3/2 loam, weak medium granular structure, very
II
A 0-8
friable, many roots
5YR 5/8 heavy sandy clay loam, moderate medium
II
Bt 8-59
subanbular blocky structure, friable, common roots
5YR 5/6 light sandy clay loam, weak medium subanbular
II
BCt 29-47
blocky structure, friable, common roots
C 47-85
5YR 5/6 heavy sandy loam, friable, few roots
II
lOYR 3/2 loam, weak medium granular structure, very
II
A 0-9
friable, many roots
5YR 3/6 clay loam, moderate medium subangular blocky
III
Bt 9-26
structure, friable, common roots
5YR 4/6 light silty clay loam, friable, few roots, commom
III
C 26-50
lOYR 4/6 and 6/6 lithochromic mottles
lOYR 2/2 loam, weak medium granular structure, very
II
A 0-6
friable, many roots
10YR 6/4 loam, weak fine subangular blocky structure,
II
E 6-14
friable, common roots
5YR 5/6 clay loam, moderate medium subangular blocky
II1
Bt 14-39
structure, friable, common roots
5YR 4/6 light silty clay loam, friable, few roots, commom
III
C 39-86
1 OYR 4/6 and 6/6 lithochromic mottles
10YR 3/2 loam, weak medium granular structure, very,
II
A 0-6
friable, many roots
SYR 5/6 clay loam, moderate medium subangular blocky
IIl
Bt 6-23
structure, friable, common roots
5YR 4/6 light silty clay loam, friable, few roots, commom
lII
C 23-48
10YR 4/6 and 6/6 lithochromic mottles
10YR 2/2 loam, weak medium granular structure, very
II
A 0-6
friable, many roots
1OYR 6/4 loam, weak fine subangular blocky structure,
II
E 6-11
friable, common roots
5YR 5/6 clay loam, moderate medium subangular blocky
1II
Bt 11-29
structure, friable, common roots
5YR 4/6 light silty clay loam, friable, few roots, commorn
III
C 29-50
10YR 4/6 and 6/6 lithochromic mottles
Cr 50+
Fractured bedrock, pervious
Heltzel Soil Consulting, LLC
Page 1(0 of cl�
Abbreviated Design - TL3 Effluent with Trenches
Site 2-1 Albemarle County PRIMARY
A.
a. Estimated percolation rate. minutes per inch)
50
b. Recommended trench bottom. (inches)
20
c. Depth to impervious strata/ or water table/ or limit of evaluation.
(inches)
60
60
60
d. Minimum separation distance required. (inches)
16
12
24
e. Separation distances in inches provided in design.
40
40
40
f. Slope (percentage)5
q. Minimum trench bottom due to slope . (inches)
6.5
h. Is the sloe greater than orequal to 10%?
No
i. If Ai is Yes, does 24 inches or greater to rock/impervious strata exist below
Ab?
Yes
j. If yes to Aj, add 1 ft. to the minimum center -to -center spacing beginning at 20%
slope and continue for each 10% slope increase above 20%. If no to Aj, add 1 ft. to
the minimum center -to -center spacing beginning at 10% slope and continue for each
10% slope increase above 10%. (Report the value, in feet, of the increase in center -to -
center spacing above the minimum).
0
B.
a.Design Type?
TO
b.Trench bottom square feet required loading rate /ft2
0.89
C.
a. Number of bedrooms.
5
b. Gallons per day in design
7S0
2.
a. Length of trench. (feet)
60
b. Length of available area. (feet)
80
E.
Width of trench. (feet)
3
F.
Number of trenches.
5
G.
Center-to-centerspacing. feet
9
H.
a. Width re uired. feet
39
b. Width of available area. feet
I.
Trench bottoms uare foota erequired.
841
J.
Trench bottoms uare foots a in design-
1200
K.
a. Is a reserve area re required? Yea
X No
b. Percent required
100°�
c. Percent available
100%
Notes: USE SITE 2-2 FOR RESERVE
Heltzel Soil Consultincl, LLC
Abbreviated Design -TL3 to Drip Disposal
Site 2-2 Albemarle County RESERVE
Page ! of Ok
A.
a. Estimated percolation rate. (minutes per inch)
80
b. Recommended drip tubing installation. (inches)
0
c. Depth to impervious strata/ or water table/ or limit of evaluation. (inches)
50
50
50
d. Minimum separation distance required. (inches)
18
12
24
e. Separation distances in inches provided in design..
50
50
5o
f. Slope (percents e)
6
a. Is the slope greater than 10, 20 or 30%?
No
i. If Ag is Yes, does 24 inches or greater to rocktimpervious strata exist
below Ab?
Yes
B
a.Design Type?
TL3
b.Soil Loading Rate, gpde
0.21
C.
a. Number of bedrooms.
5
b. Gallons per day in design
750
D.
a. Length of run. (feet)
75
b. Length of available area. (feet)
75
E.
lWidth of drip tubing. (inch)
1
F.
Number of runs.
25
G.
Center -to -centers acing. (feet)
2
H.
a. Width required, feet
49
b. Width of available area. (feet)
80
I.
a. Total square footage required
3671
b. Total square footage in design
3675
J.
a. Linear feet of drip tubing required
1786
b. Linear feet of drip tubing provided
1838
K.
a. Is a reserve area required? Yes
X
No
b. Percent required
100%
c. Percent available
100696
Notes:
Heltzel Soil Consulting, LLC
1412 Saumswlle Road, Maurertown, VA 22644
oo�
' 4 �Pl P5
SITE 2-2
\ �Q P3
$1
P2
.pl
ONSITE 2-1 1 `
Pao Y
go, --�
October 24, 2022
DRAWN BY- CSH
SITE 2-1 & 2-2 SKETCH
TM # 69-19H
ALBEMARLE COUNTY, VA
ter- ---
�s WELL AREA
P2
T.M.69-19H
Page,? of q
WELL # 121
REVISED LOT 7
11.03+/- ACRES
Heltzel Soil Consulting, LLC Page q of a
1412 $aumavhle Road, Maurartown, VA 22644
1.M.69-190 WELL#12
REVISED LOT 6 zs8, o.o
2.63 ACRES I `I^M^
(
T.M.69-19H
255' REVISED LOT 7
11.03+/- ACRES
30I,
1gQ
61iG10.1
WELL #11
T.M.69-19F
REVISED LOT 5
4.63 ACRES
....... I.- / \
October 24, 2022
DRAWN BY: CSH
WML MUU
N
0. 100, GOO' Sao,
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
LOT 6
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
POND
T.M.69-6M
REVISED LOT 7
E.C.ACKERMAN TRUST
D.B.4733-23
D.B.4733-20 & 21 PLAT
D.B.4456-444
0.8.3530-234 PLAT
STATE ROUTE 803
(30 PR GOLEASEMENT)
T.M.69-6G
LOT 1
FRANK DONLEY &
CARLA DONLEY
D.B.3380-82,
85 & 86 PLAT
II
III
I
I
I
II
II
I I
II
11
11
1I
II
I
II
I
I
II
�i
I
I
I
I
I
I
I
VDH
MONUMENT
FOUND
VDH MONUMENT FOUND
I
S..R6
/
LOT12
—y
z n xRRs
wT9
E 98 >GES
LOTH
.TN
z.zzRQES
zsondes
xm ♦cRes
z.R9auss
s
i or eivss
F19 R[P6
� 151
VDH HPg.3
Heltzel Soil Consultinq, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
(30-PRESCRIPTIVE EASEMENT)
EXISTING
STOCKTON CREEK S
ST.RT.75
oLD
Page I of 3
VDVIRGINIA Albemarle County Health Department
DEPARTMENT 1138 of Rose Hill Drive
Charlottesville, VA 22903
OF HEALTH (43.4) 972-6219 Voice
Protecting You and Your Environment (434) 972-4310 Fax
Sewage Disposal Certification Letter Approval
November 28, 2022
Stockton Creek, LLC
C/OAlan Taylor 455 APPROVED
455 Second Street SE, #201
Charlottesville, VA 22902
RE: Tax Map: 69-19H (Site DF 3-2)
HDID: 101-22-0394
Important Note: Certification Letter Approval for Site DF 3-2
Dear Alan Taylor,
This Certification Letter is issued in lieu of a sewage disposal system construction
permit in accordance with §32.1-163, et seq., of the Code of Virginia. The Board of Health
hereby recognizes that the soil and site conditions acknowledged by this correspondence, and
documented by additional records on file at the local health department, are suitable for the
installation of an onsite sewage disposal system. The attached plat shows the approved area for
the sewage disposal system. This letter is valid until a permit for construction is issued and the
system is installed, inspected and approved. This letter is void if there is any substantial physical
change in the soil or site conditions where the sewage disposal system is to be located.
The application for a certification letter was submitted pursuant to § 32.1-163.5 of the
Code of Virginia which requires the Health Department to accept private soil evaluations and
designs from an Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation
with an OSE for residential development. The site for an individual onsite sewage system was
certified as being in compliance with the Board of Health's regulations by: Chris Heltzel,
AOSE License 1940001460. This letter is issued in reliance upon that certification.
A permit to construct the sewage disposal system must be issued before constniction of
the system. If the property owner (current or future) applies for a construction permit within 18
months of the date of this letter, the application fee paid for this letter shall be applied to any
state fees for a permit to construct a sewage disposal system. After 18 months, the applicant is
responsible for paying all state fees for a permit application.
Tax Map: 69-19H (Site DF 3-2)
HDID: 101-22-0394
Page 2 of 2
This letter, and accompanying plat of survey showing the specific location of the sewage
disposal system area and well area (if applicable), may be recorded in the land records by the
clerk of the circuit court in the jurisdiction where all or part of the site or proposed site of the
system is to be located. The site shown on the plat is specific and must not be disturbed or
encroached upon by any construction. To do so voids this letter. Upon the sale or transfer of the
land that is the subject of this letter, the letter shall be transferred with the title to the property.
Future owners are advised to review the plat for the location of the onsite sewage disposal area to
make sure their building plans do not interfere with the area. If they have any questions
regarding the location of the area, they should contact the local health department for assistance.
The area evaluated, and certified by this letter, is suitable to accommodate a 4 bedroom
house using a system design of 600 gallons per day. The property will be served by a Private
water supply as shown on the attached plat. Owners are further advised that when connection to
a public water system is proposed and the public water system has reached its permitted capacity,
a permit for construction may not be issued until such time that a connection is approved and
available for use.
This letter is an assurance that a sewage disposal system construction permit will be
issued (provided there have been no substantial physical changes in the soil or site conditions
where the system would be located); however, it is not a guarantee that a permit for a specific
type of system will be issued. The design of the sewage system will be determined at the time of
application for a building permit and sewage system construction permit. The design will be
based on the site and soil conditions certified by this letter, structure size and location, water well
location (final determination to be made at time of permit issuance), the regulations in effect at
the time, and any off -site impacts that may have occurred since the date of the issuance of this
letter. In some cases, engineered plans may be required prior to issuance of the construction
permit. In accordance with § 32.1-164.1:1 of the Code of Virginia, owners are advised to apply
for a sewage disposal construction permit only when ready to begin construction.
This certification letter approval has been issued in accordance with applicable
regulations based on the information and materials provided at the time of application. There
may be other local, state, or federal laws or regulations that apply to the proposed construction of
this onsite sewage system. The owner is responsible at all times for complying with all
applicable local, state, and federal laws and regulations. If you have any questions, please contact
me.
Issued by:
Ash Kirtley
Environmental Health Technical Consultant
COMMONWEALTH OF VIRGINIA
Application for: Sewage System ❑ Water Supply
Owner. Stockton Creek LLC clo Alan Taylor
Mailing Address: 465 Second Street SE, # 201
Charlottesville, VA 22902
Agent: Stockton Creek LLC c/o Alan Taylor
Mailing Address: 455 2nd Street BE, Suite 201 Charlottesville, VA 22902
Site Address: TBO
Directions to Property.
Subdivision:
Tax Map:
Afton, VA 22920
DP 3-2
69.19H
VON USE ONLY
HeafthDepLlOkJ�J
Due Date:
Phone: 512-426-4728
Fax:
Phone:
Phone: 434-M-3694
Fax
Email. shnpmmiostlsawnstrucdo manaaememtom
Section: Block: Lot:
Other Property Info: Acreage: 11.03
Sewage System
pe of Approval: Applicants for new construction are advised to apply for a certification tether to determine It the land is suitable for a sewage
stem and to apply for a construction permit (valid for 16 months) only when ready to build.
0 Certification Letter ❑ Construction Perms ❑ Subdivison Approval ❑ Repair
reposed Use:
ngle Family Home (Number of Bedrooms) 4 Multifamily Home (Total # of Bedrooms)
:her (Describe):
Basement O Yes Walk -Out Basement? Yes Fbdures In Basement? D Yes
❑ No ❑ No ❑ No
Conditional Permit Desired? ❑ Yes [] No If yes, what type of conditions are desired?
❑ Reduced Water Flow ❑ Limited Occupancy ❑ Intermittent or seasonal use ❑ Temporary Use (t yr. ma)imum)
Do you wish to apply for a betterment loan eligibility letter? ❑ Yes"' I] No
"There is a $50 fee for determination of eligibility.
Water Supply
Will the water supply be ❑ Public or [Z Private Is the water supply ❑ EAsting or ❑' Proposed
If proposed, is this a replacement well? ❑ Yes I] No If yes, will the old well be abandoned? ❑ Yes ❑ No
Will any buildings within 5V of the well be termite treated? ❑ Yes I] No
All Applicants
Is this a private sector OSE/PE application? Yes ❑ No If yes, is the OSE package attached? l] Yes
❑ No
Is the property intended to serve as your (the owners) principal place of residence? ❑ Yes Q No
In order for VDH of process your application for a sewage system, you must attach a plat of the property and a site sketch.
a
plat of the property is recommenced and a site sketch is required. The site sketch should show your property lines, actual anoror proposea
buildings, and the desired location of your well and/or sewage system. When the site evaluation is conducted, the property bass, building location
and the proposed ge sites must be cearty marked and the property sufficiently visible to see the topography.
P
'tLTIInI give the Virglnlaant of Health to enter onto the property described during normal business hours for the purpose of
proceication and to _ 4uefl"Assurance checks of evaluations and designs certified by a private sector Onsite Soil Evaluator
or Proeer as necessal� the sewage dfsposa system and/or private water supply has been constructed and approved.
Ht:I:rZFLo. 1940001460
Signatur fdy� hse I Date
1fYarrM�la/rsaYrY�r✓mnMr�r�rlassairMA�O�rls�rrw sa awbelll9an
vox ilr as. Dar VAMnd: tine Doc
FaeS HD1D# Fbanow scar r
Firya�ittyes*4A �iDA Reoript8
Page k of (a
❑ Construction Permit ❑ Repair
Permit
OSEIPE Report For:
❑ Voluntary Upgrade F1 Certification
Permit Letter
❑ Subdivision Approval
Property Location: --- - —— -
911 Address: TBD City, State, Tip: Afton, VA 22920
Lot: Section: Subdivision: DF3.2
GPIN or Tax Map #: 69-19H Health Dept. ID A
Latitude: Longitude:
Owner:
Name: Stockton Creek LLC c/o Alan Taylor
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Prepared by:
OSE Name: Chris Helizei License # 1940-001460
Address: PO Box 554, Woodstock, VA 22664
PE Name: License #
Address:
Date of Report: 10/25M22 Date of Revision #1:
Date of Revision #2:
Contentslindex of this report:
1. Cover Sheet 5. Site Sketch
2. Soil Evaluation 6. Dralnfleld Location 8 Sanitary Survey
3. Profiles
4. Abbreviated Design
Certification Statement
1 hereby certify that the evaluations and/or designs contain herein were conducted in accordance with the applicable provisions of the
Sewage Handling & Disposal Regulations (I2VAC5.610), the Private Well Regulations (12VAC5-630), the Regulations for Alternative Onsite
Systems (12VAC5-613) and all other applicable laws, regulations, and policies implemented by the Virginia Department of Health. 1 further
certify that I currently posses any professional license required by the laws and regulations of the Commonwealth that have been duly issued
by the applicable agency charged with licensure to perform the work contained herein. The potential for both conventional and alternative
onsite sewage systems has been discussed with the owneriapplicant.
F7.3<tik
n The wo r to r page has been conducted under an exemption to the practice of engineering. specifically the
exam ofur fowSAI-401A.14
L
I recommend that Construction Pero- ° ❑ Subdivision Approval be: ❑ Issued
C '.�
ULJ Car Sii>E@t99r Z4PIRepair Permit [I Voluntary Upgrade ❑ Denied
2EL
• , Li c No. 1940001460
��2 s !2Z
o3GPr• 319natun:: PLC CAI-t -�� Date:
�hSITF 501�1
The form contains personal inform0on subject to disclosure under Me Freedom of lnformetlon Act Revised 12MI114
Page 2 of
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 5/18/2022 Submitted to: Albemarle County Health Department
Owner. Stockton Creek LLC c/o Alan Taylor Telephone Number: 512-426-4728
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: Stockton Creek LLC cro Alan Taylor Address: 455 2nd Street SE, suite 201 Chartottesvllie, VA 22WZ
Property Location: TBD Tax Map/GPIN: 69-19H
Subdivision: Blk/Sec: Site: 3-2
1. Position in Landscape Satisfactory: [] Yes ❑ No
Describe: Convex Upland Sidesio e
2. Slope: 14-16 %
3. Depth to Rock or Impervious Strata: Max. 21" Min. 19" None ❑
4. Depth to seasonal water table (gray mottling or gray color): Not Observed ❑ Yes El 19"
5. Free Water Present? 0 No ❑ Yes Range: inches
6. Soil Percolation rate estimated: 0 Yes Texture Group: 1 ❑ 11 C 111 ❑ IV ❑
❑ No Estimated rate: 75 mpi @ 1"
7. Permeability Test Performed? 2) No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
0 Site Approved. Drainfield to be placed at 1 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ Insufficient area of suitable soil for drainfield and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages if necessary)
Additional Notes:
Address: Stockton
PI
P2
P3
P4
P5
v-3 3 0"
Heltzel Soil Eval Date: 5/18/2022
Consulting Drainfield: 3-2
A0-7 '-"'_'- ....,.,u.....�.....y....Wa. o.J 11
friable, many roots
Btl 7-21 MYR 5/6 clay loam, moderate medium subangular blocky III
structure, friable, common roots
Bt2 21 �3
SYR 5/6 heavy sandy clay loam, weak medium subangular
II
blocky structure, slightly firm, few roots, common IOYR
6/2 iron depletions, few IOTA 2/1 Mn concentrations
C 33-67
SYR 6/6 heavy sandy clay loam, friable, few roots, common
10YR 6/8 lithochromic mottles ='
A 0-7
1 OYR 4/3 loam, weak medium granular structure,very R
friable, many roots
Btl 7-20
7.5YR 5/6 clay loam, moderate medium subangular blocky III
structure, friable, common roots
Bt2 20�8
SYR 5/6 heavy sandy clay loam, weak medium subangular
II
blocky structure, slightly firm, few roots, common IOYR
6/2 iron depletions, few 10YR 2/1 Mn concentrations
C 35-60
SYR 6/6 heavy sandy clay loam, friable, few roots, common
II
10YR 6/8 lithochromic mottles
A 0-6
IOYR 4/3 loam, weak medium granular structure,very
Il
friable. many roots
Btl 6-19
T YR 5/6 clay loam, moderate medium subangular blocky
III
structure, friable, common roots
Bt2 19-32
SYR 8/6 heavy sandy clay loam, weak medium subangular
II
blocky structure, slightly firm, few roots, common 1 OYR
6/2 iron depletions, few 1 OYR 2/1 Mn concentrations
C 32 60
SYR 5/4 heavy sandy clay loam, friable, few roots, few
II
1 OYR 6/6 lithochromic mottles
A 0-8
1OYR 4/3 loam, weak medium granular structure,very
II
friable, many roots
Btl B-21
7.8YR 5/6 clay loam, moderate medium subangular blocky
III
structure, friable, common roots
Bt2 21-36 SYR 5/6 heavy sandy clay loam, weak medium subangular II
blocky structure, slightly firm, few roots, few 1 OYR 6/2 iron
depletions, few IOYR 2/1 Mn concentrations
5YR 5/8 sandy clay loam, friable, few roots, common I OTR
C 38-84 6/8 lithochromic mottles II
A 0.7 IOYR 4/3 Ioam, weak medium granular strncture,very 11
friable, many roosts
Btl 7-20 7.5YR 5/6 clay loam, moderate medium subangular blocky III
structure, friable, common roots
SYR 5/6 heavy sandy clay loam, weak medium subangular
Bt2 20.35 blocky structure, slightly firm, few roots, common 1 OYR II
6/2 iron depletions, few 10YR 2/1 Mn concentrations
C 35-65 SYR 5/9 heavy sandy day loam, friable, few roots, common II
1 OYR 6/8 lithochromic mottles
Heitzel Soil Consultinia, LLC
Abbreviated Design -TL3 to Drip Disposal
Site 3-2 Albemarle County
Page q of �O
A.
a. Estimated percolation rate. (minutes per inch)
75
b. Recommended drip tubing installation. (inches)
1
c. Depth to impervious strata/ or water table/ or limit of evaluation. (inches)
19
19
19
d. Minimum separation distance required. (inches)
18
12
24
e. Separation distances in inches provided in design.
18
18
18
f. Slope (percentage)
16
g. Is the slope greater than 10, 20 or 30%?
Yes
I. If Ag is Yes, does 24 inches or greater to rocktimpervious strata exist
below Ab?
No
B.
a.Design Type?
TU
b.Soil Loading Rate, d/ftz
0.22
C.
a. Number of bedrooms.
4
b. Gallons per day in design
600
D.
a. Length of run. (feet)
90
b. Length of available area. (feet)
90
E.
Width of drip tubing. (inch)
1
F.
I Number of runs.
16
G.
Center-to-centerspacing. (feet)
2
H.
a. Width required, feet
31
b. Width of available area. (feet)
63
1.
a. Totalsquare footage required
2727
b. Total square footage in design
2790
J.
a. Linear feet of drip tubing required
1364
b. Linear feet of drip tubing provided
1395
K.
a. Is a reserve area required? Yes
X
No
b. Percent required
100%
c. percent available
100%
Notes: Reserve Design is same as Primary
Heltzel Soil Consulting, LLC
1412 Saumsv7le Road, Mauredown, VA 22644
0
WELL AREA
WE 2-2
P3 P2♦
October 24, 2022
DRAWN BY: CSH
SITE 3-2 SKETCH
TM # 69-19H
ALBEMARLE COUNTY, VA
-�U
# 13 1-0-\`
voo�vr
PUFFER
51%
'OPI
Page -' of `O
z
SITE 3-2 3 '
1OP5
6`0
r >� �
o\ P4
WELL AREA
-WELL # 12
Heltzel Soil Consulting, LLC Page of`O
1412 SaummAle Road, Maurertown, VA 22644
616'—
.ao.od
T.M.69-19G I \ WELL#12
REVISED LOT 6 zs�P, o.o�
2.63 ACRES I
I
300'
T.M.69-19F
REVISED LOT 5
4.63 ACRES
October 24, 2022
DRAWN BY: CSH
T.M.69-19H
REVISED LOT 7
11.03+/— ACRES
1
O' 100' QOO' 300,
'Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22684
T.M.69-6L
LOT 6
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
POND
T.M.69-6M
REVISED LOT 7
E.C.ACKERMAN TRUST
D.B.4733-23
D.B.4733-20 & 21 PLAT
D.B.4456-444
D.B.3530-234 PLAT
STATE ROUTE 803
(30'PRESCRIPTIVE EASEMENT)
GOODLOE LANE
T.M.69-6G
LOT 1
FRANK DONLEY &
CARLA DONLEY
D.B.3380-82,
85 & 86 PLAT
II
II
I
1
II
II
II
11
11
11
11
it
II
II
t
II
I
1
II
I
I
I
I
I
I
I
VDH
MONUMENT
FOUND
VDH MONUMENT FOUND
PROPOSE[
STOCKTON CREEK
S
LOTS
29B AGES
LOT 11
L4T IU :.l3RGE
ssoawEs
n� lam\
m
Lm 3.
:.macro
ELL IlB
Lm ae
lM PG6
�E tz1oe R�fW
SCPS
�V p 0 e
VDH H�P93'
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
POND
(30-PRESCRIP11VE EASEMENT)
VDH
MONUMENT
FOUND
VDH MONUMENT FOUND
EXISTING
STOCKTON CREEK S
T.M.69-19G
V REVSED LOT 6
\.} 2.63 ACRES
/m
T.M.69-19F
y REVISED LOT 5
�E1 4.63 ACRES
. e. •�,.
Eu.:
T.M.69-19E
a
REVISED LOT 4
4.62 ACRES
SL
u-�
p
Lea
T.M.69-19D
REVISED LOT 3
4.56 ACRES
ELL 00
au
T.M.69-19
RENSE LO za 11.03+ — A(
IIr.
T.M.89
REVISED
7.70 A
/ C
VDH
MONUMENT
FOUND
RGINIA
VXDHOFIHEA HEALTH
DEPARTMENT
Protecting You and Your Environment
Sewage Disposal Certification Letter Approval
November 28, 2022
Stockton Creek, LLC
C/O Alan Taylor
455 Second Street SE, #201
Charlottesville, VA 22902
RE: Tax Map: 69-19J (Site DF 4-2)
HDID:101-22-0395
Page] of 3
Albemarle County Health Department
1138 Rose Hill Drive
Charlottesville, VA 22903
(434) 972-6219 Voice
(434) 972-43 10 Fax
APPROVED
Important Note: Certification Letter Approval for Site DF 4-2
Dear Alan Taylor,
This Certification Letter is issued in lieu of a sewage disposal system construction
permit in accordance with §32.1-163, et seq., of the Code of Virginia. The Board of Health
hereby recognizes that the soil and site conditions acknowledged by this correspondence, and
documented by additional records on file at the local health department, are suitable for the
installation of an onsite sewage disposal system. The attached plat shows the approved area for
the sewage disposal system. This letter is valid until a permit for construction is issued and the
system is installed, inspected and approved. This letter is void if there is any substantial physical
change in the soil or site conditions where the sewage disposal system is to be located.
The application for a certification letter was submitted pursuant to § 32.1-163.5 of the
Code of Virginia which requires the Health Department to accept private soil evaluations and
designs from an Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation
with an OSE for residential development. The site for an individual onsite sewage system was
certified as being in compliance with the Board of Health's regulations by: Chris Heltzel,
License 1940001460. This letter is issued in reliance upon that certification.
A permit to construct the sewage disposal system must be issued before construction of
the system. If the property owner (current or future) applies for a construction permit within 18
months of the date of this letter, the application fee paid for this letter shall be applied to any
state fees for a permit to construct a sewage disposal system. After 18 months, the applicant is
responsible for paying all state fees for a permit application.
Tax Map: 69-19J (Site DF 4-2)
HDID: 101-22-0395
Page 2 of 2
This letter, and accompanying plat of survey showing the specific location of the sewage
disposal system area and well area (if applicable), may be recorded in the land records by the
clerk of the circuit court in the jurisdiction where all or part of the site or proposed site of the
system is to be located. The site shown on the plat is specific and must not be disturbed or
encroached upon by any construction. To do so voids this letter. Upon the sale or transfer of the
land that is the subject of this letter, the letter shall be transferred with the title to the property.
Future owners are advised to review the plat for the location of the onsite sewage disposal area to
make sure their building plans do not interfere with the area. If they have any questions
regarding the location of the area, they should contact the local health department for assistance.
The area evaluated, and certified by this letter, is suitable to accommodate a 3 bedroom
house using a system design of 450 gallons per day. The property will be served by a Private
water supply as shown on the attached plat. Owners are further advised that when connection to
a public water system is proposed and the public water system has reached its permitted capacity,
a permit for construction may not be issued until such time that a connection is approved and
available for use.
This letter is an assurance that a sewage disposal system construction permit will be
issued (provided there have been no substantial physical changes in the soil or site conditions
where the system would be located); however, it is not a guarantee that a permit for a specific
type of system will be issued. The design of the sewage system will be determined at the time of
application for a building permit and sewage system construction permit. The design will be
based on the site and soil conditions certified by this letter, structure size and location, water well
location (final determination to be made at time of permit issuance), the regulations in effect at
the time, and any off -site impacts that may have occurred since the date of the issuance of this
letter. In some cases, engineered plans may be required prior to issuance of the construction
permit. In accordance with § 32.1-164.1:1 of the Code of Virginia owners are advised to apply
for a sewage disposal construction permit only when ready to begin construction.
This certification letter approval has been issued in accordance with applicable
regulations based on the information and materials provided at the time of application. There
may be other local, state, or federal laws or regulations that apply to the proposed construction of
this onsite sewage system. The owner is responsible at all times for complying with all
applicable local, state, and federal laws and regulations. If you have any questions, please contact
me.
Issued by:
sh Kirtley
'Environmental Health Technical Consultant
COMMONWEALTH OF VIRGINIA
Application for 0 Sewage System ❑ Water Supply
Owner: Stockton Creek LLC c/o Alan Taylor
Mailing Address: 455 Second Street BE, 0 201
Charlottesville, VA22902
Agent: Stockton Creek LLC c/o Alan Taylor
Mailing Address: 458 2nd Street BE, Suite 201 Charlottesville, VA 22902
Site Address: TED
Directions to Property: Comer of Route 280 8 Route 15f
Subdivision: DF 4.2 Section:
Tax Map: 69-19.1 Other Property Info:
VDM UISE ONLY
Health Dept IDe+nCjS-
Due Date:
Phone: 512-426 4728
Fax:
Phone:
Phone: 434-981-3634
Fax:
Email: simpwn&uasconsouoeonmenegenwntcan
Block:
Lot:
Amon.- 111411
Sewage System
Type of Approval: Applicants for new construction are advised to apply for a certification letter to determine If the land Is suitable for a sewage
system and to apply for a construction permit (vaffd for 18 months) only when ready to build.
0 Certification Letter ❑ Construction Permit ❑ SubdMeon Approval ❑ Repair
Proposed Use:
Single Family Home (Number of Bedrooms) 3 MUitifamily Home (Total d of Bedrooms)
Other (Describe):
Basement 0 Yes Walk -Out Basement? 9 Yes Fbdures In Basemerd? 0 Yes
❑ No ❑ No ❑ No
Conditional Perna Desired? ❑ Yes 0 No If yes, what type of conditions are desired?
❑ Reduced Water Flow ❑ Limited Occupancy ❑ Intermittent or seasonal use ❑ Temporary Use (1 yr. ma)imum)
Do you wish to apply for a betterment loan eligibility letter? ❑ Yes" 0 No
Water Supply
Will the water supply be ❑ Public or 0 Private is the water supply ❑ Existlng or 0 Proposed
If proposed, Is this a replacement well? ❑ Yes O No If yes, will the old well be abandoned? ❑ Yes ❑ No
Will any buildings within 50' of the well be termite treated? ❑ Yes 0 No
All Appllearft
Is this a private sector OSFJPE application? Yes ❑ No If yes, Is the OSE package attached? 0 Yes
Is the property Intended to serve as your (the owners') principal place of residence? ❑ Yes 0 No ❑ No
In order for VDH of process your application for a sewage system, you must attach a plat of the property and a site sketch. For water supplies, a
olat of the omoanv Is rammmnn~i n d s see eye. d re
buildings, and the
and the or000sad
I awe n to the Virainis
PrOM881§Xft application
or Pro BIIreI EBailt" O
Signature
_._ _.__ _.._._.. _..__._ ..... Y,,,., ",v -'Y ..,.ea,'a, anuwur proposea
W
of your well and/or sewage system. When the site evaluation is conducted, the property fines, building location
ftftes must be dearly marked and the property sufficiently visible to see the topography.
yicNo 194000/460
of Health to enter onto the property described during normal bualness hours for the purpose of
ualky assurance checks of evaluations and designs certified by a private sector Onsite Soll Evaluator
the sewage disposal Pystem and/or private water supply has been constructed and approved.
O (2�?1-4Z
•eras�n.s.ti.�i�� - �ywr.aar�,...arr.►.�a�rrr.r..na Mwrrt119ra
omBrawab Dora Doc
P4e3 Hm0 FIMN"asoti
PoomootOVetbeckM MWO Raoelotl
Date
Page of t0
❑ Construction Permit ❑ Repair
Permit
1 Address: TBD
GPIN or Tax Map #:
Latitude:
1.
Creek
ared by:
Name: Chita Haffzel
Name:
OSE/PE Report For:
❑ Voluntary Upgrade
Permit
1Z Certification
Letter
Section: Subdivision: DF4.2
B8.1tlJ Health Dept. ID #:
Longitude:
I;'3
Date of Report: 10/2&2022 Date of Revision #1:
Date of Revision #2:
of this report:
vwwwo� n
tic Site Sketch
6 DreirMe/d Location & Senftary Survey
City, State, Zip:
License #
License #
❑ Subdivision Approval
I hereby certify that the evaluations and/or designs contain herein were conducted in accordance with the applicable provisions of the
Sewage Handling & Disposal Regulations (12VAC5-610), the Private Well Regulations (12VAC"30), the Regulations forAftemattve Onstte
Systems (12VAC6.613) and all other applicable Ism, regulations, and policies Implemented by the Virginia Department of Health. I further
xrtify that I currently posses any professional license required by the laws and regulations of the Commonwealth that have been duly issued
by the applicable agency charged with licensure to perform the work contained herein. The potential for both conventional and aftemstNe
)nsite sewage systems has been di caged with the owner/applicant.
O The work
recommend that a:
Signature:
to this, has been conducted under an exemption to the practice of engineering, specifically the
Vr of ginia 64.1-402.A.11
natru it % ❑ Subdivision Approval
948g@[p60 [� epair Permit ❑ Voluntary Upgrade
Zi
Date:
be: [Z Issued
❑ Denied
�Olts (22
The form contains personal information subject to disclosure under the Freedom of Information Act. Revised *101/14
Page?, of
Date: 5/18/2022 Submitted to: Albemarle County Health Department
Owner: Stockton Creek LLC c/o Alan Taylor Telephone Number: 512-426-47
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: Stockton Creek LLC do Alan Ta for
Property Location: TBD
Subdivision:
Address: ass end street
Tax Map/GPIN:
Blk/Sec:
1. Position in Landscape Satisfactory: O Yes ❑ No
Describe: Convex Upland Sideslope
2. Slope: 44846 %
3. Depth to Rock or Impervious Strata: Max. 40" Min. 21"
4. Depth to seasonal water table (gray mottling or gray color): Not Observed ❑
5. Free Water Present? 0 No ❑ Yes Range:
6. Soil Percolation rate estimated: 0 Yes Texture Group: I ❑
❑ No Estimated rate:
7. Permeability Test Performed? 0 No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
Site:
None ❑
Yes 21"
II ❑ 111 EO
80 mpi @ 1"
inches
IV ❑
O Site Approved. Drainfield to be placed at 1 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
--- 1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ Insufficient area of suitable soil for drainfield and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages if necessary)
Notes.
Address, Stockton Creek
PI
P2
P3
P4
PS
Pjj -3
Reltze15oil 16oa1 Date: 8/1812022
CortStrltiWQ Drainfleld: 4-2
Ap 0-5
lOYR 3/3 sandy loam, weak fine subangular blocky
structure, friable, many roots
II
E 5-11
IOYR 6/4 sandy loam, weak medium subangular blocky
structure, friable, many roots
II
Bt 11-22
M 8/6 sandy clay loam, moderate medium subangular
blocky structure, friable, common roots
II
Cd 22-83
5YR 5/6 and 10YR 6/6 sandy loam, firm, few 10YR 6/2 iron
depletions, few 2.BYR 8/6 iron concentrations
II
Ap 0-8
1 OYR 3/3 sandy loam, weak fine subangular blocky
structure, friable, many roots
II
Btl 8-20
7.SYR 5/8 sandy clay loam, moderate medium subangular
blocky structure, friable, common roots
II
Bt2 20-40
SYR 8/6 light clay loam, weak medium subangular blocky
structure, friable, common roots
III
SYR 3/4 and 1 OYR 4/6 silty clay loam, slightly firm, few
C 40-56
roots, few 10YR 6/1 iron depletions, common 10YR 8/6
III
lithochromic mottles
A 0-6
1 OYR 3/3 sandy loam, weak fine subangular blocky
structure, friable, many roots
II
E 6-16
IOYR 8/4 heavy sandy loam, weak medium subangular
blocky structure, friable, many roots
II
Bt 18-27
7'M 8/6 clay loam, moderate medium subangular blocky
structure, friable, few roots
Cd 27-84
7.8YR 8/4 clay loam, firm, common IOYR 6/1 iron
depletions
III
A 0-7
1 OYR 3/3 sandy loam, weak fine subangular blocky
structure, friable, many roots
II
Btl 7-23
SYR 8/6 clay loam, moderate medium subangular blocky
structure, friable, common roots
IIl
7.SYR 5/6 clay loam, moderate medium subangular blocky
Bt2 23-42
structure, slightly firm, few roots, few IOYR 6/1 iron
M
depletions
Cd 42-60
7'SYR 5/4 clay loam, firm, common 10YR 6/1 iron
depletions
III
A 0-8
1 OYR 3/3 sandy loam, weak fine subangular blocky
structure, friable, many roots
II
Btl 8-21
SYR 8/6 clay loam, moderate medium subangular blocky
structure, friable, common roots
III
Bt2 21-40 T.BYR 5/6 clay loam, moderate medium subangular blocky III
structure; slightly firm, few roots, IOYR 6/1 iron depletions
Cd 40-60 7.8YR 8/4 clay loam, firm, common IOYR 6/1 iron III
depletions
Heltzel Soil Consulting, LLC
Abbreviated Design -TL3 to Drip Disposal
Site 4-2 Albemarle County
Page � of (v
A.
a. Estimated percolation rate. minutes per inch
70
b. Recommended drip tubing installation. inches
1
c. Depth to impervious strata/ or water table/ or limit of evaluation. (inches)
21
21
21
d. Minimum separation distance required '
e uired. Inches
18
12
24
e. Separation distances in inches provided in deli n.
20
20
20
f. Sloe (percentage)
12
Is the slope greater than 10, 20 or 30%?
Yes
i. If Ag is Yes, does 24 inches or greater to rockrimpervious strata exist
below Ab?
No
g
a.Design Type?
TL3
b.Soil Loading Rate, d/ftz
0.24
C.
a. Number of bedrooms.
3
b. Gallons per day in design
450
D.
a. Length of run. feet
85
b. Length of available area. feet
85
E.
Width of drip tubing. inch
1
F.
Number of runs.
13
G.
Center-to-centerspacing. (feet)
2
H.
a. Width required, feet
25
b. Width of available area. feet
50
I.
a. Totalsquare footage required
1875
b. Totalsquare footage in design
2125
J.
a. Linear feet of drip tubing required
938
b. Linear feet of drip tubing provided
1063
K.
a. Is a reserve area required? Yes
X
No
b. Percent required
100%
c. Percent available
100%
Notes: Design is the same for RESERVE
Heltzel Soil Consulting, LLC
1412 Saumswlle Road, Maurartown, VA 22644
Page 6r of `O
SITE 4-2 SKETCH
TM # 69-191
ALBEMARLE COUNTY, VA
I... _. LOCATION
AM BUFFER
SITE 3-2
�C
WELL # 12
October 24, 2022
DRAWN BY: CSH
.ps
SPI'E 4-2
T�
O' OO' 100' 150'
Heltzel Soil Co
1412 SaumaviDe Road, Meurertown, VA 22644
REAM BUFFER '
I
#12
9-19H
D LOT 7
/- ACRES
Itin
LLC
Page b of b I
DRAINFIELD LOCATION SKETCH
TM # 69-191
ALBEMARLE COUNTY, VA
452' P
WELL #14 rr j'
me
WEU naew
TELL #15
I 06
I
I
I
T. M
8.7
° I
T.M.69-19JREVISED
LOT 8
N8.92+/-
16t
ACRES
� tj
WELL #16
/
w
i
i
36'
.w
October 28, 2022
DRAWN BY: SNV
°' 300•
woo•
3°°'
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
LOT 6
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
POND
T.M.69-6M
REMSED LOT 7
E.C.ACKERMAN TRUST
D.B.4733-23
D.B.4733-20 & 21 PLAT
D.B.4456-444
D.B.3530-234 PLAT
STATE ROUTE 803
(30-PRESCRIPTIVE EASEMENT)
GOODLOE LANE
T.M.69-6G
LOT 1
FRANK DONLEY &
CARLA DONLEY
D.B.3380-82,
85 & 86 PLAT
.:.:::: ... AA1 BUFFER
OVERHEAD
UTILTY
/ / sus Acnss uL.0 L LINE �
..
0°1 .,x m
x.PCPES
u
x
I,�
RocU SR
(VgR�sy UUT
9 69`h5>}f�R ojIr
L°:a ^ti, 30i �W
�FqM�
NOT TO SCALE
wH
MONUMENT
FOUND
LINES w
MONUI
., FOUI
LOT Ll
L9 ACRE5 .S
LOI N »n AwEs ms eu..n -YN Lx°AUArnEs usncxu
s OLE rota roN
L Q0'm'
m' PDIS C wH
Kr
x OS AI
ONUMENT
FOUND
`+HELL
wH
:C. .H MONUMENT
n ;3>'u:. FOUND
n.�0 �csus 1 343ACAES
CORNER
FvC FENCE POST
VDH
MONUMENT
C \ ^ a wH FOUND
LOT
S
1
MONUMENT
T&VDH
SjpSE R�AO�D jw
CR��'E91F- Vt�3 y PA q1�i
:N P p1 B 4, q09
wH MONUMENT FOUND H Pg3
wH
FOUND
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
(30'PRESCRIPTIVE EASEMENT)
EXISTING LOT LAYOUT
STOCKTON CREEK SBD, ALBEMARLE CO, VA
\T.M.69-190
/// REVISED LOT 6
2.63 ACRES
POND T.M.69-19F
REMSED LOT 5
4.63 ACRES
VDH �
MONUMENT
FOUND
VDH MONUMENT
FOUND
051
ST.RT.750 (30'PRESCRIPTIVE EASEMENT)
OLD TURNPIKE ROAD
LOCATION STREAM
e
6�VSED LOT 7
3+/ ACRES
u
T.M.69-19E
REVSED LOT 4
4.62 ACRES 2�
pB, T.M.69-19C
REVISED LOT 2
2• 7.70 ACRES
u �
�x �
T.M.69-19D
REVISED LOT 3
4.56 ACRES
T.M.69-19J
REMSEO LOT 8
8.92+/- ACRE!
ELL la /
■
REMSEDLOT 1
3.64 ACRES
150 �OOU EI
ZP� SOSE NOpt\RRIW
5 v P EN04 Y713,��&U 2Y1i
VDFI 09• ,209
MONUMENT ,11{P83
FOUND N
VDH
MONUMENT
FOUND
JU
(qR lY 0 2so
6.2600
93���Np/ke
0%
I '4F
eG�i'
I R
OVERHEAD
UTILITY
LINES
REVISED
T.M.69-508
73 ACRES
1
F11 •1
P LE
NOT TO SCALE
VDH
JUMENT
VDH
MONUMENT
FOUND
�aY N
Q o vY
z�N
n, N
Q.O.
\ VDH ?
�-mONUMENT
FOUND
VDH
MONUMENT
`CORNER IN
FENCE POST
VDH
MONUMENT
VDH FOUND
RGINIA
VIDHOFIHEAI.MH
Protecting You and Your Environment
Sewage Disposal Certification Letter Approval
November 28, 2022
Stockton Creek, LLC
C/O Alan Taylor
455 Second Street SE, #201
Charlottesville, VA 22902
RE: Tax Map: 69-19J (Site DF 5)
HDID: 101-22-0396
Page 1 of 3
Albemarle County Health Department
1138 Rose Hill Drive
Charlottesville, VA 22903
(434) 972-6219 Voice
(434) 972-43 10 Fax
Important Note: Certification Approval for Site DF 5
Dear Alan Taylor,
This Certification Letter is issued in lieu of a sewage disposal system construction
permit in accordance with §32.1-163, et seq., of the Code of Virginia. The Board of Health
hereby recognizes that the soil and site conditions acknowledged by this correspondence, and
documented by additional records on file at the local health department, are suitable for the
installation of an onsite sewage disposal system. The attached plat shows the approved area for
the sewage disposal system. This letter is valid until a permit for construction is issued and the
system is installed, inspected and approved. This letter is void if there is any substantial physical
change in the soil or site conditions where the sewage disposal system is to be located.
The application for a certification letter was submitted pursuant to § 32.1-163.5 of the
Code of Virginia which requires the Health Department to accept private soil evaluations and
designs from an Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation
with an OSE for residential development. The site for an individual onsite sewage system was
certified as being in compliance with the Board of Health's regulations by: Chris Heltzel,
License 1940001460. This letter is issued in reliance upon that certification.
A permit to construct the sewage disposal system must be issued before construction of
the system. If the property owner (current or future) applies for a construction permit within 1 E
months of the date of this letter, the application fee paid for this letter shall be applied to any
state fees for a permit to construct a sewage disposal system. After 18 months, the applicant is
responsible for paying all state fees for a permit application.
Tax Map: 69-19J (Site DF5)
HDID: 101-22-0396
Page 2 of 2
This letter, and accompanying plat of survey showing the specific location of the sewage
disposal system area and well area (if applicable), may be recorded in the land records by the
clerk of the circuit court in the jurisdiction where all or part of the site or proposed site of the
system is to be located. The site shown on the plat is specific and must not be disturbed or
encroached upon by any construction. To do so voids this letter. Upon the sale or transfer of the
land that is the subject of this letter, the letter shall be transferred with the title to the property.
Future owners are advised to review the plat for the location of the onsite sewage disposal area to
make sure their building plans do not interfere with the area. If they have any questions
regarding the location of the area, they should contact the local health department for assistance.
The area evaluated, and certified by this letter, is suitable to accommodate a 4 bedroom
house using a system design of 600 gallons per day. The property will be served by a Private
water supply as shown on the attached plat. Owners are further advised that when connection to
a public water system is proposed and the public water system has reached its permitted capacity,
a permit for construction may not be issued until such time that a connection is approved and
available for use.
This letter is an assurance that a sewage disposal system construction permit will be
issued (provided there have been no substantial physical changes in the soil or site conditions
where the system would be located); however, it is not a guarantee that a permit for a specific
type of system will be issued. The design of the sewage system will be determined at the time of
application for a building permit and sewage system construction permit. The design will be
based on the site and soil conditions certified by this letter, structure size and location, water well
location (final determination to be made at time of permit issuance), the regulations in effect at
the time, and any off -site impacts that may have occurred since the date of the issuance of this
letter. In some cases, engineered plans may be required prior to issuance of the construction
permit. In accordance with § 32.1-164.1:1 of the Code of Virginia owners are advised to apply
for a sewage disposal construction permit only when ready to begin construction.
This certification letter approval has been issued in accordance with applicable
regulations based on the information and materials provided at the time of application. There
may be other local, state, or federal laws or regulations that apply to the proposed construction of
this onsite sewage system. The owner is responsible at all times for complying with all
applicable local, state, and federal laws and regulations. If you have any questions, please contact
me.
Issued by:
1000-
sh Kirtley
Environmental Health Technical Consultant
COMMONWEALTH OF VIRGINIA
Application for ID sewage System ❑ Water Supply
Owner Stockton Creek LLC c/o Alan Taylor
Melling Address; 465 Second Street SE, 0 201
Charlottesville, VA 22902
Agent: Stockton Creak LLC cfo Alan Taylor
Mailing Address: 456 2nd Street BE, Suite 2o1 Charlottesville, VA 22902
Site Address: TBD
Afton, VA 22920
Directions to Property;I Corner of f ute 2W & RavM f C1
Subdivision: DF 5 Section:
Tax Map: 69-19J Other Property info:
ID
VDH USE ONLY
Health Dept. ID#l"^- •Oj (;
Due Date:
Phone: 512426.4728
Fax:
Phone:
Phone; 434-981.3634
Fax:
Email: simpeondlommmbrusddonmamgementcom
Block:
Lot:
Acreage: 6.92
Sewage sys�ffloalion
of Approval: Applicants for new construction are advised to apply for a letter to determine if the land Is suitable for a sewagen and to apply fora construction permit (valid for 1@ months) only whendy to build.
Certification Letter ❑ Construction Permit
Proposed Use:
Single Family Home. (Number of Bedroom*) 4
Other (Describe):
❑ Subdivison Approval ❑ Repair
MutilFamily Home (Total 9 of Bedrooms)
Basement ❑ Yes Walk -Out Basement? ❑ Yea Fixtures n Basement?
ID No iB❑ Yea
❑ No ❑ No
Conditional Permit Desired? ❑ Yes Q No If yes, what type of conditions are desired?
❑ Reduced Water Flow ❑ Limited Occupancy ❑ IntenNttent or seasonal use ❑ Temporary Use (1 yr. maximum)
Do you wish to apply for a betterment loan eligibility letter? ❑ Yes" 0 No
"Thare is a $50 fee for determinatinn of winihmh,
Will the water supply be ❑ Public or ❑ private rIs the water supply ❑ Existing or ❑ Proposed
If proposed, is this a replacement well? ❑ Yes No If yes, will the old well be abandoned? ❑ Yes ❑ No
Will ar. bulldin s within 5U' of the well be termite treated? ❑ Yes No
Is this a private sector OSEIPE application? � All Applicants
❑ Yes ❑ No If yes, Is the OSE package attached? Yes
Is the property Intended to serve as ) principal P El No
your (the owners) rind al lace of residence? ❑ Yea � No
In order for VDH of process your epplk:atlon for a sewage system, you must attach a plat of the properly end a site sketch. For water supplies, a
punt of the property la recommenced and a she sketch Is required. The site sketch should show your property Ilnea, actual and/or proposed buildings, and t sired location of your well and/or sewage system. When the she evaluation Is oontlucted, the property lines, truiWing tocatlor.
and the swage sites must be decry marked and the property suificie Wslbie to see the to
r blR.. �` pogrePhY.
mineion to the VIrdbleveParunOnt of Neagh to enter onto the property described during normal business hours for the purpose of
10 this ap�on e d ! arform quality assurance checks of evaluations and designs ceN9ed-try a private sector Onalte Sou Evaluator
slor r �ht. ary until the sewage dispossi system and/or private water supply P has been constructed and approved.
KO ,9A ��
�'� T/�,� .� \ ( o t243 i 22
Date
Dm t Dow
FaaS RDIDf P11MMIu Moot r
?4=1112MINtilinkill MW# Reo*!
Pass of g
❑ Construction Permit ❑ Repair
Permit
Property Location:
911 Address: TBD
Lot: Section:
GPI N or Tax Map #. 69-191
Prepared by:
OSE Name: Chris Hsj&e/
Address: PO
PE Name:
VA
OSE/PE Report For:
❑ Voluntary Upgrade ED Certification
Permit Letter
Subdivision: DF5
Health Dept. ID #:
Longitude:
-•- - r , .vi carat[ Date of Revision #1:
Date of Revision #2:
of this report:
S. Site Sketch
& DralnWd Location & Sanitary Survey
City, State, Zip:
License #
License #
❑ Subdivision Approval
22920
I hereby certify that the evaluations and/or designs contain herein were conducted in accordance with the applicable provisions of the
Sewage Handling & Disposal Regulations (12VAC5-610), the Private Well Regulations (12VAC5.630), the Regulations for ARemat/ve Onslte
Systems (12VAC5-613) and all other applicable laws, regulations, and policies Implemented by the Virginia Department of Hearth. I further
certify that I currently posses any professional license required by the laws and regulations of the Commonwealth that have been duly issued
by the applicable agency charged with licensure to perform the work contained herein. The potential for butt. conventional and alternative
onsite sewage systems has been discussed with the owner/applicant.
G The wo '� `
§�4d tbith�'tover page has been conducted under an exemption to the practice of engineering, specifically the
exemItCode of Vlr r. Section 54.1-402.A. 11
recommend that 0�❑Constructlopgsm 'r. ❑ Subdivision Approval be: ❑ Issued
��Le( �] Repair Permit El Voluntary Upgrade El Denied
O .ty1y�• � •' /�
SE/PE Signature Date: O` z V
The form contalnS personal urformetbn Subject to 0780mure under /he Fmedo of Informeffon Act
_. — Revised 12ID1114
Page 2 of G
SOIL SUMMARY REPORT
GENERAL INFORMATION
F
10/27/2021 Submitted to: Albemarle County Health Department
Stockton Creek LLC Go Alan Taylor Telephone Number. 512 4261t728
ress: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: StocMon creek LLC cto Alen Taylor Address: 455 2nd Sleet SE, sure tot CharlotleWoe, VA 22902
Property Location: TBD Tax Map/GPIN: 69-19.1
Subdivision: Blk/Sec: Site: 5-1
1. Position in Landscape Satisfactory: O Yes ❑ No
Describe: Convex Upland Sideslo e
2. Slope: 6 %
3. Depth to Rock or Impervious Strata: Max. 33" Min. 19" None ❑
4. Depth to seasonal water table (gray mottling or gray color): Not Observed ❑ Yes P1 19"
5. Free Water Present? 121 No ❑ Yes Range: inches
6. Soil Percolation rate estimated: 1Z Yes Texture Group: I ❑ II ❑ III 0 IV ❑
❑ No Estimated rate: 80 mpi @ 1"
7. Permeability Test Performed? El No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
O Site Approved. Drainfield to be placed at 1 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ Insufficient area of suitable soil for drainfield and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages if necessary)
Additional Notea:
93 3 oar(.
Heltzel Soil Eval Date; 10/27/21
Address; Stockton Creek Consul tirw
Draiafield•5-1
Profile IHorl2onl 1]enth I
Pl Ap 0-8
. V .n "` `Odin, wean memum granular structure, very
friable, many roots
—
II
E 5-12
10YR 8/4 loam, weak medium subangular blocky structure,
friable, common roots
II
Bt 12-33
8YR 8/8 clay loam, moderate medium subangular blocky
structure, friable, common roots
III
C 33-60
SYR 5/8 and 10YR 6/6 heavy silty clay loam, friable, few
roots, few 10YR 6/2 iron depletions
III
P2 Ap 0-4
1 OYR 2/2 loam, weak medium granular structure, very
friable, many roots
II
E 4-11
10YR 8/4 loam, weak medium subangular blocky structure,
friable, common roots
II
Bt 11-24
8YR 5/8 clay loam, moderate medium subangular blocky
structure, friable, common roots
III
C 24-89
SYR 5/8 and 1 OYR 6/6 heavy silty clay loam, friable, few
roots, few 1 OYR 6/2 iron depletions
III
P3 Ap 0-6
10YR 2/2 loam, weak medium granular structure, very
friable, many roots
II
Bt 8-19
SYR 5/8 clay loam, moderate medium subangular blocky
structure, friable, common roots
III
C 19-46
SYR 6/6 and 1 OYR 6/8 clay loam, firm, few 1 OYR 6/2 iron
depletions
III
P4 A 0-6
10YR 2/2 loam, weak medium granular structure, very
friable, many roots
II
E 6-11
1 OYR 5/4 loam, weak medium subangular blocky structure,
friable, common roots
II
Bt 11-21
SYR 5/8 clay loam, moderate medium subangular blocky
structure, friable, common roots
III
C 21-80
5YR 5/6 clay loam, fum, few 10YR 6/2 iron depletions, few
10YR 6/6 lithochromic mottles
III
PS A 0-7
1 OYR 2/2 loam, weak medium granular structure, very
friable, many roots
lI
Bt 7-23
7'SYR 5/6 clay loam, moderate medium subangular blocky
structure, friable, common roots
III
C 25-74
2.5YR 5/8 and IGYR 6/8 heavy silty clay loam, firm, few
roots
III
Ps A 0.3
10YR 2/2 loam, weak medium granular structure, very
friable, many roots
II
E 5-11
10YR 8/4 loam, weak medium subangular blocky structure,
friable, common roots
II
Bf i 1-25
SYR 9/8 clay loam, moderate medium subangular blocky
structure, friable, common roots
C 28-51
6YR 8/8 and 1 OYR 6/6 silty day loam, friable, few roots, few
1 OYR 6/2 iron depletions
III
Heitzei Soil Consulting LLC
Abbreviated Design -TL3 to Drip Disposal
Site 5-1 Albemarle County
Page 4 of G
ercolation rate. (minutes er inch)
80
nded dri tubin installation. inches)
1
=Estimated
pervious strata/ or water table/ or limit of evaluation. (inches)
e aration distance required. (inches
2121
1
distances in inches provided in design.
20 20 20
f. Slope ercenta e)
9
Is the slope greater than 10, 20 or 30%?
No
I. If Ag is Yes, does 24 inches or greater to roc�mpervious strata exist
below Ab?
No
B
a.Design Type?
TL3
b.Soil Loadin Rate, gpde
EqE4
C.
a. Number of bedrooms.
b. Gallons erda in desi n
D.
a. Len th of run. (feet
100
b. Len th of available area. (feet)
100
E.
Width of drip tubing. (inch)
1
F.
Number of runs.
1s
G.
Center -to -centers acin .(f=afl
2
H.
a. Width required, feet
31
b. Width of available area. (feet)
67
I.
a. Total square footage require
2857
b. Total square foota a in design
3100
J.
a. Linear feet of dri tubin required
1429
b. Linear feet of dri tubin provided
1650
K.
a. Is a reserve area re uired? Yes
X No
b. Percent re uired
100%
c. Percent available
100%
Notes: Design is the same for RESERVE
Heltzel Soil Consulting LLC
1412 Saumsdle Road, Mauredown, VA 22644
#12
SITE 5-1 SKETCH
TM # 69-19J
ALBEMARLE COUNTY, VA
100.00,
Page 4!� of (o
me \--/--
WELL AREA
October 24, 2022
DRAWN BY: CSH 'O' '°°" "
Heltzel Soil Consulti
1412 Saumevllle Road, Maurartown, VA 22644
REAM BUFFER '
I
#12
9-19H
D LOT 7
ACRES
I
WELL MMA
October 28, 2022
DRAWN BY: SNV
LLC
DRAINFIELD LOCATION SKETCH
TM # 69-19J
ALBEMARLE COUNTY, VA
Page l of b I
f
1 06
1
61 T. M
3nBbt 8.7
�_. T.M.69-19J
1361
REVISED LOT 8
8.92+/- ACRES,
� WELL#16 /
w
i
(loom
O' 100• 200, 300'
Heltzel Soil Consulting, LLC
PO Box 554. Woodstock, VA 22664
T.M.69-6L
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
POND
(30'PRESCRIP7IVE EASEMENT)
VDH �
MONUMENT
FOUND
VDH MONUMENT FOUND
EXISTING
STOCKTON CREEK S
T.M.69-19G
���/// REVISED LOT 6
fie.
2.63 ACRES
�^�^
®
T.MS.6E9p-191
ins 11%,( S/ ��
lot-
t� 3� /
T.M.69-19F
REVISED LOT 5 \\
/\ 4.63 ACRES
REVISED LOT 4
4.62 ACRES
E
lti >
14,
T.M.69-
aka
REVISED
2 •
7.70 Al
-ME
L
TM.69-19D
REVISED LOT 3
4.56 ACRES
e'
ELLMJ9
S
/
VDH
MONUMENT
FOUND
7
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
LOT 6
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
POND
T.M.69-6M
REVISED LOT 7
E.C.ACKERMAN TRUST
D.B.4733-23
D.B.4733-20 & 21 PLAT
D.B.4456-444
D.B.3530-234 PLAT
STATE ROUTE 803
(30'PR G ODLOE LEASEMENT)
T.M.69-6G
LOT 1
FRANK DONLEY &
CARLA DONLEY
D.B.3380-82,
85 & 86 PLAT
wH MONUMENT
wH �
MONUMENT
FOUND
PROPOSH
STOCKTON CREEK S
.Tw
2M RCPES
`// znuxa
SE �g1
SIN -579
NPO8A�2� M1tU
VX wH 01.1?
VYDHOFI HEAtTH ENT
Protecting You and Your Environment
Sewage Disposal Certification Letter Approval
November 28, 2022
Page l of 3
Albemarle County Health Department
1138 Rose Hill Drive
Charlottesville, VA 22903
(434) 972-6219 Voice
(434) 972-4310 Fax
Stockton Creek, LLC
C/O Alan Taylor
455 Second Street SE, 4201 pppRp�ED
Charlottesville, VA 22902
RE: Tax Map: 69-19J (Site DF 9)
HDID: 101-22-0399
Important Note: Certification Letter Approval for Site DF 9
Dear Alan Taylor,
This Certification Letter is issued in lieu of a sewage disposal system construction
permit in accordance with §32.1-163. et seq., of the Code of Virginia. The Board of Health
hereby recognizes that the soil and site conditions acknowledged by this correspondence, and
documented by additional records on file at the local health department, are suitable for the
installation of an onsite sewage disposal system. The attached plat shows the approved area for
the sewage disposal system. This letter is valid until a permit for construction is issued and the
system is installed, inspected and approved. This letter is void if there is any substantial physical
change in the soil or site conditions where the sewage disposal system is to be located.
The application for a certification letter was submitted pursuant to § 32.1-163.5 of the
Code of Virginia which requires the Health Department to accept private soil evaluations and
designs from an Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation
with an OSE for residential development. The site for an individual onsite sewage system was
certified as being in compliance with the Board of Health's regulations by: Chris Heltzel,
AOSE License 1940001460. This letter is issued in reliance upon that certification.
A permit to construct the sewage disposal system must be issued before construction of
the system. If the property owner (current or future) applies for a construction permit within 18
months of the date of this letter, the application fee paid for this letter shall be applied to any
state fees for a permit to construct a sewage disposal system. After 18 months, the applicant is
responsible for paying all state fees for a permit application.
Tax Map: 69-19J (Site DF 9)
HDID: 101-22-0399
Page 2 of 2
This letter, and accompanying plat of survey showing the specific location of the sewage
disposal system area and well area (if applicable), may be recorded in the land records by the
clerk of the circuit court in the jurisdiction where all or part of the site or proposed site of the
system is to be located. The site shown on the plat is specific and must not be disturbed or
encroached upon by any construction. To do so voids this letter. Upon the sale or transfer of the
land that is the subject of this letter, the letter shall be transferred with the title to the property.
Future owners are advised to review the plat for the location of the onsite sewage disposal area to
make sure their building plans do not interfere with the area. If they have any questions
regarding the location of the area, they should contact the local health department for assistance.
The area evaluated, and certified by this letter, is suitable to accommodate a 5 bedroom
house using a system design of 750 gallons per day. The property will be served by a Private
water supply as shown on the attached plat. Owners are further advised that when connection to
a public water system is proposed and the public water system has reached its permitted capacity,
a permit for construction may not be issued until such time that a connection is approved and
available for use.
This letter is an assurance that a sewage disposal system construction permit will be
issued (provided there have been no substantial physical changes in the soil or site conditions
where the system would be located); however, it is not a guarantee that a permit for a specific
type of system will be issued. The design of the sewage system will be determined at the time of
application for a building permit and sewage system construction permit. The design will be
based on the site and soil conditions certified by this letter, structure size and location, water well
location (final determination to be made at time of permit issuance), the regulations in effect at
the time, and any off -site impacts that may have occurred since the date of the issuance of this
letter. In some cases, engineered plans may be required prior to issuance of the construction
permit. In accordance with § 32.1-164.1:1 of the Code of Virginia, owners are advised to apply
for a sewage disposal construction permit only when ready to begin construction.
This certification letter approval has been issued in accordance with applicable
regulations based on the information and materials provided at the time of application. There
may be other local, state, or federal laws or regulations that apply to the proposed construction of
this onsitc sewage system. The owner is responsible at all times for complying with all
applicable local, state, and federal laws and regulations. If you have any questions, please contact
me.
Issueed by:
i /
sh Kirtley
Environmental Health Technical Consultant
COMMONWEALTH OF VIRGINIA
AppllWion for, 0 Sewage System ❑ Water Supply
Owner: Stockton Creek LLC c/o Alan Taylor
Mailing Address: 455 Second Street BE, 111201
Charlottesville, VA 22902
Agent: Stockton Creek LLC c/o Alan Taylor
Mailing Address: 4M 2nd Street BE, Suite 201 Charlottesville, VA 22902
Site Address: TBD
Afton, VA 22920
Directions to Property:
Comer of Route 250 B Route f5f
Phone:
Fax:
VDH USE ONLY
Health Dept. IDS 10 ' 22.03` q
Due Date:
612-4264728
Phone:
Phone: 434-981.3634
Fax:
Emall: simpsonifileaasoonsbuctlonmenagemwA.cam
Subdivision: DF 9 Section: Block: Lot:
Tax Map: 69.19J Other Property Into: Acreage: 8.92
Sewage System
Type of Approval: Applicants for new construction are advised to apply for a certification letter to determine if the land Is suitable for a sewage
system and to apply for a construction permit (valid for 18 months) only when ready to build.
0 Certification Letter ❑ Construction Permit ❑ Subdivison Approval ❑ Repair
Proposed Use:
Single Family Home (Number of Bedrooms) 5 Multifamily Home (Total # of Bedrooms)
Other (Describe):
Basement Yes Walk -Out Basement? F±1 Yes Fbrhires in Basement? Yes
❑ No ❑ No ❑ No
Conditional Permit Desired? ❑ Yea E] No ifyes, what type of conditions are desired?
❑ Reduced Water Flow ❑ Limited Occupancy ❑ Intermittent or seasonal use ❑ Temporary Use (1 yr. maximum)
Do you wish to apply for a betterment loan eligibility letter? ❑ Yes' O No
Water Supply
Will the water supply be ❑ Public or Private Is the water supply ❑ Existing or 21 Proposed
If proposed, is this a replacement well? ❑ Yes No byes, will the old well be abandoned? ❑ Yes ❑ No
Will any buildings within 60' of the well be termite treated? ❑ Yes ❑' No
All Applicants
Is this a private sector OSE/PE application? El Yes ❑ No If yes, Is the OSE package attached? p Yes
❑ No
Is the property Intended to serve as your (the owners') principal place of residence?
In order for VDH of process your application for a sewage system, you must attach a
❑ Yes 0 No
a
a
plat of the property Is recommenced and a she sketch Is required. The site sketch should show your property Ones, actual and/or proposed
buildings, and the desired location of your well and/or sewage system. When the site evaluation Is conducted, the property lines, building location
and the proposed well and sewage sites must be clearly marked and the property sufficiently visible to see the topography.
I give pe "7h6. i + partmem of Health to enter onto the property described during normal business hours for the purpose of
application at{rF dorm gualfir assurance chocks at evaluations and pastime cer9fled by a private sector Onsite Soil Evaluator
or s�%net Engineer as until the sewage di s el system and/or private water supply has been constructed and approved.
CtkRH51
EO Z�n $ 7
c) 1940001460
Sion ra.o er(Aaertt ., Date
Y M Sgaw
OLUM lr Dure Braatsat DMDW
66— mm if Pfnd.! MGM 0 _
b m""aw"o MmIr Reasgittf,
page— — of
❑ Construction Permit ❑ Repair
Permit
OSEIPE Report For:
❑ Voluntary Upgrade
Permit
Certification
Letter
❑ Subdivision Approval
Property Location:
911 Address: TBD City, State, Zip: Afton, VA 22920
Lot: Section: Subdivision: DF 9
GPIN or Tax Map #: 69.191 Health Dept. ID #:
Latitude: Longitude:
Owner:
Name: Stockton Creek LLC do Alan Taylor
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Prepared by:
OSE Name: Chris Heltzet License # 1940-001460
Address: PO Box 564, Woodstock VA 22664
PE Name: License #
Address:
Date of Report: 10/26/2022 Date of Revision #1:
Date of Revision #2:
Contente/index of this report:
1. Cover Sheet 5. Site Sketch
2. Soil Evaluation 6. Drainfield Location B Sanitary Survey
3. Profiles
4. Abbreviated Design
Certification Statement
I hereby certify that the evaluations and/or designs contain herein were conducted in accordance with the applicable provisions of the
Sewage Handling & Disposal Regulations (12VAC5-610), the Private We# Regulations (12VAC5-630), the Regulations forAttemetive Onslte
Systems (12VAC5-613) and all other applicable laws, regulations, and policies implemented by the Virginia Department of Health. I further
certify that I currently posses any professional license required by the laws and regulations of the Commonwealth that have been duly Issued
by the applicable agency charged with Ilcensure to perform the worK contained herein. The pote" ial for both conventional and altemative
onsite sewage systems has been discussed with the owner/applicant.
C The work ' cover page has been conducted under an exemption to the practice of engineering, specifically the
exam ¢dde Section 54.1 402.A.11
G
I recommend that] Construction Pef�ai ❑ Subdivision Approval be: 0 issued
ller7 ❑ Repair JPermit ❑ Voluntary Upgrade /�❑ Denied
r Lic No.1940001460 m (Zg (2
o5E/PE 5ignatu L i Date,
N� Hwy
Tne form contafas personal hdormefion subject to disclosure under tha Freedom of Information Act. Revised 12101114
Page of L
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 10/31/2021 Submitted to: Albemarle County Health Department
Owner. Stockton Creek LLC Go Alan Taylor Telephone Number. 512-426-4728
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: Stoddon Creek LLC do Alan Taylor Address: 455 2nd Street SE: Suite 201 Cheriottesdlie, VA 22902
Property Location: TBD Tax Map/GPIN: 69-19J
Subdivision: BlklSec: Site: 9-1
1. Position in Landscape Satisfactory: O Yes ❑ No
Describe: Convex Upland Sideslo e
2. Slope: 6 %
3. Depth to Rock or Impervious Strata: Max. 24" Min. 20" None ❑
4. Depth to seasonal water table (gray mottling or gray color): Not Observed ❑ Yes [21 20"
5. Free Water Present? O No ❑ Yes Range: inches
6. Soil Percolation rate estimated: 0 Yes Texture Group: I ❑ II ❑ III [21 IV ❑
❑ No Estimated rate: 90 mpi @ 1"
7. Permeability Test Performed? 2 No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
0 Site Approved. Drainfield to be placed at 1 " depth at site designated on permit.
Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ Insufficient area of suitable soil for drainfield and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages if necessary)
Additional Notes:
b 3."
Atldseaa: Stockton Creek
Profile IHorizonl Depth
Heltzel Soil
Cronsnitia�
Eval Date: 10/31/21
Drainfield: 8-1
I OYR 4/3 silt loam, weak medium granular structure, very
III
PI Ap
0-5
friable, many roots
IOYR 6/4 loam, weak fine subangular blocky structure,
II
E
5-10
friable, common roots
SYR 3/8 clay loam, moderate medium subangular blocky
Bt
10-24
structure, friable, common roots
2.5YR 3/6 and SYR 5/8 silty clay loam, slightly firm, few
C
24-46 roots, common IOYR 6/8 lithochromic mottles, few 10YR
III
8/1 iron depletions
1OYR 4/3 silt loam, weak medium granular structure, very
III
P2 Ap
0-3
friable, many roots
IOYR 5/4 loam, weak fine subangular blocky structure,
II
E
3-12
friable, common roots
SYR 6/8 clay loam, moderate medium subangular blocky
III
Bt
12-22
structure, friable, common roots
2.8YR 5/6 and SYR 5/8 silty clay loam, slightly firm, few
C
22-48 roots, common 10YR 6/8 lithochromic mottles, few IOYR
III
6/1 iron depletions
lOYR 4/3 silt loam, weak medium granular structure, very
III
P3 Ap
0-4
friable, many roots
IOYR 6/4 loam, weak fine subangular blocky structure,
II
E
4-10
friable, common roots
7.8YR 5/6 clay loam, moderate medium subangular blocky
III
Bt
10-22
structure, friable, common roots
7.5YR 5/8 and 8" 5/8 silty clay loam, slightly firm, few
C
22-45 roots, common IOYR 6/8 lithochromic mottles, few IOYR
III
6/1 iron depletions
IOYR 4/3 silt loam, weak medium granular structure, very
III
P4 A
0-3
friable, many roots
10YR 6/4 loam, weak fine subangular blocky structure,
II
E
3-10
friable, common roots
SYR 5/8 clay loam, moderate medium subangular blocky
III
Bt
10-20
structure, friable, common roots
2.SYR 8/6 and SYR 5/8 silty clay loam, slightly firm, few
III
C
20-48
roots, common IOYR 6/2 iron depletions
lOYR 4/3 silt loam, weak medium granular structure, very
III
PS Ap
0-5
friable, many roots
lOYR 6/4 loam, weak fine subangular blocky structure,
II
E
6-12
friable, common roots
7.8YR 5/6 clay loam, moderate medium subangular blocky
Bt
12-24
structure, friable, common roots
7.8YR 5/8 and BYR 6/8 silty clay loam, slightly firm, few
C
24-48 roots, common IOYR 6/8 lithochromic mottles, few IOYR
III
6/1 iron depletions
Heltzel Soil Consulting, LLC
Abbreviated Design -TL3 to Drip Disposal
Site 9-1 Albemarle County
Page '� of b
A.
a. Estimated percolation rate. (minutes per inch)
90
b. Recommended drip tubing installation. inches
1
c. Depth to impervious strata/ or water table/ or limit of evaluation. (inches)
20
20
20
d. Minimum separation distance required. (inches)
19
12
24
e. Separation distances in inches provided in design.
19
19
19
f. Slope (percentage)
6
Is the slope greater than 10, 20 or 30%?
No
i. If Ag is Yes, does 24 inches or greater to rock/impervious strata exist
below Ab?
No
B
a.Design Type?
TL3
b.Soil Loading Rate, d/ft2
0.19
C.
a. Number of bedrooms.
5
b. Gallons per day in design
750
D.
a. Length of run. (feet)
75
b. Length of available area. (feet)
75
E.
lWidth of drip tubing. (inch)
1
F.
Number of runs.
30
G.
Center -to -center spacing. (feet)
2
H.
a. Width required, feet
59
b. Width of available area. feet
141
I.
a. Total square footage required
3947
b. Totalsquare footage in design
4425
J.
a. Linear feet of drip tubing required
1974
b. Linear feet of drip tubing provided
2213
K.
a. Is a reserve area required? Yes
X
No
b. Percent required
100%
c. Percent available
100%
Notes: Design is the same for RESERVE
Heltzel Soil Consulting, LLC
1412 SaumWile Road, Mauredow, VA 226"
SITE 9-1 SKETCH
TM # 69-19J
ALBEMARLE COUNTY, VA
P2
1P1 WE 9-1 *P5 P3i � \
04 �0
142►
-�6 �-/-�
Page ; of G
Jac; \.
WELL AREA
WELL \ T.M.69-19J
REVISED LOT 8
i \\,,- V 8_92+ /- ACRES
October 24, 2022 0• eo• too, 150,
DRAWN BY: CSH iiiia
Heltzel Soil Consulting, LLC
1412 Saumsvllle Road, Maurertown, VA 22644
REAM BUFFER i
#12
9-19H
D LOT 7
ACRES I
7 WELD
ARM I
DRAINFIELD LOCATION SKETCH
TM # 69-19J
ALBEMARLE COUNTY, VA
452' P O L
„ WELL #14
1we (0 of(a
I m eaen I ' o
5� ��.ad
uic
w��
I
#15
I
October 28, 2022
DRAWN BY: SNV
R
I---
Ila T.M.
Eau 8.7
113 VIEU T.M.69-19J 00
EA
REVISED LOT
8.92+/- AC
WELL #16 /
W
O' 100' 200, 300'
Heltzel Soil Consulting, LLC
PO Box 564, Woodstock, VA 22664
T.M.69-6L
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
(30'PRESCRIPTIVE EASEMENT)
VDH MONUMENT FOUND
EXISTING
STOCKTON CREEK S
ST.RT.7°
oLD
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
LOT 6
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
T.M.69-6M
REVISED LOT 7
E.C.ACKERMAN TRUST
D.B.4733-23
D.B.4733-20 & 21 PLAT
D.B.4456-444
D.B.3530-234 PLAT
PROPOSEC
STOCKTON CREEK S
VDHOFEHEALTHVIRGINIA
PARTMEHT
Protecting You and Your Environment
Sewa$e Disposal Certification Letter Approval
December 7, 2022
Stockton Creek, LLC
CIO Alan Taylor
455 Second Street SE, #201
Charlottesville, VA 22902
RE: Tax Map: 69-50B (Site 7A-1 & 8A-1))
HDID: 101-22-0397
Page 1 of 3
Albemarle County Health Department
1138 Rose Hill Drive
Charlottesville, VA 22903
(434) 972-6219 Voice
(434) 972-4310 Fax
APPROVED
Important Note: Certification Letter Approval for Site DF 7A-1 & 8A-1
Dear Alan Taylor,
This Certification Letter is issued in lieu of a sewage disposal system construction
permit in accordance with §32.1-163, et seq., of the Code of Virginia. The Board of Health
hereby recognizes that the soil and site conditions acknowledged by this correspondence, and
documented by additional records on file at the local health department, are suitable for the
installation of an onsite sewage disposal system. The attached plat shows the approved area for
the sewage disposal system. This letter is valid until a permit for construction is issued and the
system is installed, inspected and approved. This letter is void if there is any substantial physical
change in the soil or site conditions where the sewage disposal system is to be located.
The application for a certification letter was submitted pursuant to § 32.1-163.5 of the
Code of Virginia which requires the Health Department to accept private soil evaluations and
designs from an Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation
with an OSE for residential development. The site for an individual onsite sewage system was
certified as being in compliance with the Board of Health's regulations by: Chris Heltzel,
AOSE License 1940001460. This letter is issued in reliance upon that certification.
A permit to construct the sewage disposal system must be issued before construction of
the system. If the property owner (current or future) applies for a construction permit within 18
months of the date of this letter, the application fee paid for this letter shall be applied to any
state fees for a permit to construct a sewage disposal system. After 18 months, the applicant is
responsible for paying all state fees for a permit application.
Tax Map: 69-50B (Site DF 7A-I & 8A-1)
HDID: 101-22-0397
Page 2 of 2
This letter, and accompanying plat of survey showing the specific location of the sewage
disposal system area and well area (if applicable), may be recorded in the land records by the
clerk of the circuit court in the jurisdiction where all or part of the site or proposed site of the
system is to be located. The site shown on the plat is specific and must not be disturbed or
encroached upon by any construction. To do so voids this letter. Upon the sale or transfer of the
land that is the subject of this letter, the letter shall be transferred with the title to the property.
Future owners are advised to review the plat for the location of the onsite sewage disposal area to
make sure their building plans do not interfere with the area. If they have any questions
regarding the location of the area, they should contact the local health department for assistance.
The area evaluated, and certified by this letter, is suitable to accommodate a 5 bedroom
house using a system design of 750 gallons per day. The property will be served by a Private
water supply as shown on the attached plat. Owners are further advised that when connection to
a public water system is proposed and the public water system has reached its permitted capacity,
a permit for construction may not be issued until such time that a connection is approved and
available for use.
This letter is an assurance that a sewage disposal system construction permit will be
issued (provided there have been no substantial physical changes in the soil or site conditions
where the system would be located), however, it is not a guarantee that a permit for a specific
type of system will be issued. The design of the sewage system will be determined at the time of
application for a building permit and sewage system construction permit. The design will be
based on the site and soil conditions certified by this letter, structure size and location, water well
location (final determination to be made at time of permit issuance), the regulations in effect at
the time, and any off -site impacts that may have occurred since the date of the issuance of this
letter. In some cases, engineered plans may be required prior to issuance of the construction
permit. In accordance with § 32.1-164.1:1 of the Code of Virginia, owners are advised to apply
for a sewage disposal construction permit only when ready to begin construction.
This certification letter approval has been issued in accordance with applicable
regulations based on the information and materials provided at the time of application. There
may be other local, state, or federal laws or regulations that apply to the proposed construction of
this onsite sewage system. The owner is responsible at all times for complying with all
applicable local, state, and federal laws and regulations. If you have any questions, please contact
me.
Issued by:
/ed/
h Kirtley
Environmental Health Technical Consultant
COMMONWEALTH OF VIRGINIA
Application for, 2 Sewage System ❑ Water Supply
(honer. Stockton Creek LLC c/o Alan Taylor
Mailing Address: 455 Second Street SE, # 201
Charlottesville, VA 22902
Agent: Stockton Creek LLC clo Alan Taylor
Mailing Address: 455 2nd Street SE, Suite 201 Charlottesville, VA 22902
Site Address: THD
Afton, VA 22920
Directions to Property.
Comer of Route 250 & Route 151
VDH USE ONLY
Health Dept. IN 10) -ZZ-0347
Due Date:
Phone: 512426.4728
Fax:
Phone:
Phone: 434-881-3834
Fax
Email: a,mpeen@ytlaecooebuctbmnanaeemmtcom
Subdivision: DF 7A-1 & SA-1 Section: Block: Lot:
Tax Map: 89-51013 Other Property Info: Acreage: 8.73
Sewage System
Type of Approval: Applicants for new construction are advised to apply for a certification letter to determine if the land is suitable for a sewage
system and to apply for a construction permit (valid for 18 months) only when ready to build.
❑ Certification Letter ❑ Construction Permit ❑ Subdivison Approval ❑ Repair
Proposed Use:
Single Family Home (Number of Bedrooms) 5 Multifamily Home (Total # of Bedrooms)
Other (Describe):
Basement Yes Walk -Out Basement? Yes Fbdures in Basement? Yes
❑ No ❑ No ❑ No
Conditional Permit Desired? ❑ Yes G No If yea, what type of conditions are desired?
❑ Reduced Water Flow ❑ Limited Occupancy ❑ Intermittent or seasonal use ❑ Temporary Use (1 yr. maximum)
Do you wish to apply for a betterment loan eligibility letter? ❑ Yes" [D No
"There is a $50 fee for determination of eligibility.
Water Supply
Will the water supply be ❑ Public or F'j Prime Is the water supply ❑ ExisBng or [21 Proposed
If proposed, is this a replacement well? ❑ Yes No If yes, will the old well be abandoned? ❑ Yes ❑ No
Will any buildings within 50' of the well be termite treated? ❑ Yes No
All Applicants
Is this a private sector OSEIPE application? @I Yes ❑ No If yes, Is the OSE package attached? Yes
❑ No
Is the property Intended to serve as your (the owners') principal place of residence? ❑ Yea 0 No
In order for VDH of process your application for a sewage system, you must attach a plat of the property and a site sketch. For water supplies, a
plat of the property is recommenced and a site sketch is required. The site sketch should show your property lines, actual and/or proposed
buildings, and the d i location of your well and/or sewage system. When the site evaluation Is conducted, the property lines, building location
and the pro a sites must be clearly marked and the property sufficiently visible to see the topography.
I give p ssAIn to the Virginla
or F'ro Tonal to lmrHa neom
of Health to enter onto the property described during normal bualneaa hours for the purpose of
ualty assurance checks of evaluations and designs certified by a private sector Onade Soil Evaluator
the sewage disposal system and/or private water supply has been constructed and approved.
Date
sari.,�..r�.�s..r.runr..sr.re.wws...�r.�n.r..tr.rr.�ae. anlrr>rraws
YiiiJ�i�6c Duet. DweDave
Pitm"Opehleet# E1D# Race*11
Page of _a
❑ Construction Permit ❑ Repair
Permit
OSEIPE Report For:
❑ Voluntary Upgrade Certification
Permit Letter
❑ Subdivision Approval
Property Location:
911 Address: TBD City, State, Zip: Afton, VA 22920
Lot: Section: Subdivision: DF7A-1 & 8A-1
GPIN or Tax Map # 09-SOB Health Dept. ID #
Latituae: Longitude:
Owner :
Name: Stockton Creek LLC Go Alan Taylor
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Prepared by:
OSE Name: Chris Heltzel License # 1940-001460
Address: PO Box 554, Woodstock, VA 22604
PE Name: License #
Address:
Date of Report: 10/28/2022 Date of Revision 0111:
Date of Revision #2:
Contentslindax of this report:
1. Cover Sheet 9. Site Sketch
2-3. Soli Summaries 9. Drainifile/d Location & Sanitary Survey
4-5. Profiles
0.7. Abbreviated Designs
Cord icatlon Statement
I hereby certify that the evaluations and/or designs contain herein were conducted in accordance with the applicable provisions of the
Sewage Handling & Disposal Regulations (12VAC5.610), the Private Well Regulations (12VAC5.630), the Regulations for A/temative Onsite
Systems (12VAC5.613) and all other applicable laws, regulations, and policies implemented by the Virginia Department of Health. I further
certify that i currently posses any professional license required by the laws and regulations of the Commonwealth that have been duly issued
by the applicable agency charged with licensure to perform the work contained herein. The potential for both conventional and alternative
onsite sewage systems has been discussed with the owner/applicant.
❑�ne'-^
cover page has been conducted under an exemption to the practice of engineering, specifically the
la Section 54.1-402.A.I I
I recomment ❑ Subdivision Approval be: ❑ Issued
qo ❑ Repair Permit ❑ Voluntary Upgrade ❑ Denied
OSEIPE SiData
r' CQA.��vFonhst,`�s
The form contains personal information subject to disclosure under the Freedom of Urformation Act Revised 12)01114
Page 2 of
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 9/10/2021 Submitted to: Albemarle County Health Department
Owner: Stockton Creek LLC c/o Alan Taylor Telephone Number. 512-426-4728
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: Stoddon Creek LLC Go Alan Taylor Address: 455 2nd Stmet SE, Suite 201 Charlottesville, VA 22902
Property Location: TBD Tax Map/GPIN: 69-50B
Subdivision: Blk/Sec: Site: 8A-1
1. Position in Landscape Satisfactory: 171 Yes ❑ No
Describe: Convex Upland Sidesio e
2. Slope: 14 %
3. Depth to Rock or Impervious Strata: Max. 60+" Min. None ❑
4. Depth to seasonal water table (gray mottling or gray color): Not Observed 0 Yes ❑
5. Free Water Present? 0 No ❑ Yes Range: inches
6. Soil Percolation rate estimated: ❑ Yes Texture Group: I ❑ 11 ❑ 111 ❑ IV ❑
No Estimated rate: 75 mpi @ 20"
7. Permeability Test Performed? El No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
❑ Site Approved. Drainfield to be placed at 20 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ tnsufficient area of suitable soil for drainfield and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages if necessary)
Additional Notes: PRIMARY
Page 3 of Ck
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 9/10/2021 Submitted to: Albemarle County Health Department
Owner: Stockton Creek LLC c/o Alan Taylor Telephone Number: 5124264728
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
:Agent: Stockton Creek LLC do Alan. Taylor Address: 455 2nd Street SE, Suite 201 Charlottesville, VA 22902
Property Location: TBD Tax Map/GPIN: 69-50B
Subdivision: Blk/Sec: Site: 7A-1
1. Position in Landscape Satisfactory: 21 Yes ❑ No
Describe: Convex Upland Sideslo e
2. Slope: 13 %
3. Depth to Rock or Impervious Strata: Max. 59"+ Min. None
4. Depth to seasonal water table (gray mottling or gray color): Not Observed O Yes ❑
5. Free Water Present? 0 No ❑ Yes Range: inches
6. Soil Percolation rate estimated: Yes Texture Group: I ❑ II O 111 ❑ IV ❑
❑ No Estimated rate: 75 mpi @ 15"
7. Permeability Test Performed? O No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
0 Site Approved. Drainfield to be placed at 15 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ Insufficient area of suitable soil for drainfield and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages if necessary)
Additional Notes: 100% RESERVE
Py s(o"
Address: Stockton Creek
Heltzel Soil
Consuitina
Eval Date:9/10/2021
Dr4infield•8A-1
1 Profile
jHorizor
Depth
I Description
pexuirel
1OYR 4/3 silty clay, weak fine subangular blocky structure,
IV
Pl Ap
0-9
friable, many roots
SYR 3/6 silty clay loam, moderate medium subangular
III
Bt
9-25
blocky structure, friable, common roots, 8% cobbles
SYR 4/6 silty clay loam, weak medium subangular blocky
BCt
26-38 structure, friable, common roots, 5% cobbles, common
III
IOYR 6/6 parent material mottles
1OYR 6/6 and SYR 5/6 light silty clay loam, structureless-
C
35-58
massive, friable, few roots, 8% cobbles
P2 Ap
0-9 10YR 4/3 silty clay, weak fine subangular blocky structure,
IV
friable, many roots
8YR 8/6 silty clay loam, moderate medium subangular
III
Bt
9-22 blocky structure, friable, common roots, 5% cobbles
SYR 4/6 silty clay loam, weak medium subangular blocky
BCt
22-33 structure, friable, common roots, 8% cobbles, common
III
IOYR 9/8 parent material mottles
IOYR 6/6 and SYR 5/6 light silty clay loam, structureless-
III
C
33 88
massive friable, few roots, 8% cobbles
IOYR 4/3 silty clay, weak fine subangular blocky structure,
rV
P3 Ap
0 6 friable, many roots
SYR 5/6 clay loam, moderate medium subangular blocky
III
Bt
8�5 structure, friable, common roots, 5% cobbles
SYR 5/6 silty clay loam, weak coarse subangular blocky
BCt
38-40 structure, friable, common roots, S% cobbles, common
III
10YR 6/6 parent material mottles
SYR 5/8 and 1 OYR 6/8 light silty clay loam, structureless-
III
Ct
40-80
massive, friable, few roots, 5% cobbles
10YR 4/3 silty clay, weak fine subangular blocky structure,
IV
P4 A p
0-9
friable, many roots
SYR 5/6 clay loam, moderate medium subangular blocky
ffi
Bt
9-32
structure, friable, common roots, 5% cobbles
SYR 8/6 silty clay loam, weak coarse subangular blocky
BCt
32-38 structure, friable, common roots, 5% cobbles, common
III
lOYR 6/6 parent material mottles
SYR 8/8 and 1 OYR 6/8 light silty clay loam, structureless-
III
C
38-60
massive, friable, few roots, 8% cobbles
IOYR 4/3 silty clay, weak fine subangular blocky structure,
rV
PS A p
0-T
friable, zany roots
SYR 5/8 clay loam, moderate medium subangular blocky
III
Bt
T-35
structure, friable, common roots, 8% cobbles
SYR 8/8 silty clay loam, weak coarse subangular blocky
BCt
35-43 structure, friable, common roots, 5% cobbles, common
in
1 OYR 6/6 parent material mottles
SYR 5/6 and IOYR 6/6 light silty clay loam, structureless-
III
C
43-60
massive, friable, few roots, 5% cobbles
(9 Saka
Address: Stockton Creek
PI
P2
P3
P4
P5
Seltael soil
Eval Date:s/10/2021
Drainfield: TA-1
10YR 4/3 silt loam, weak medium granular structure,
Ap
0-8
friable, many roots
5YR 6/6 clay loam, strong medium subangular blocky
Bt
8-24
structure, friable, common roots
5TR 6/8 and lOTR 6/6 light silty clay loam, weak medium
BCt
24-33
subangular blocky structure, friable, few roots
SYR 5/6 and IOYR 6/8 silt loam, structureless-massive,
C
33-56
friable, few roots
Ap
0-9 1 OYR 4/3 silt loam, weak medium granular structure,
friable, many roots
Bn 6/6 clay loam, strong medium subangular blocky
III
Bt
9-25
structure, friable, common roots, 8% cobbles
BCt
25-32 5YR 6/6 and 10YR 6/6 light silty clay loam, weak medium
III
subangular blocky structure, friable, few roots, 3% cobbles
SYR 8/6 and 10TR 6/8 silt loam, struchrreleas-massive,
III
C
32-86
friable, few roots
lOTR 4/3 silt loam, weak medium granular structure,
III
Ap
0-8
friable, many roots
SYR 6/6 clay loam, strong medium subangular blocky
M
Btl
8-85
structure, friable, common roots
SYR 5/6 silty clay loam, moderate medium subangular
Bt2
26-40 blocky structure, friable, few roots, few 10YR 4/6 parent
III
material mottles
SYR 5/6 heavy silt loam, structureless-massive, friable, few
III
C
40-89
roots, few IOYR 6/2 iron depletions
10YR 4/3 silt loam, weak medium granular structure,
III
Ap
0 T
friable, many roots
SYR 6/6 clay loam, strong medium subangular blocky
III
Bt
7-23
structure, friable, common roots
SYR 6/8 and IOYR 6/6 light silty clay loam, weak medium
III
BCt
23-34
subangular blocky structure, friable, few roots
SYR 5/8 and 10YR 6/8 silt loam, structureless-massive,
III
C
34-54
friable, few roots
IOYR 4/3 silt loam, weak medium granular structure,
III
Ap
0-6
friable, many roots
8TR 6/6 clay loam, strong medium subangular blocky
III
Bt
6-26
structure, friable, common roots
SYR 6/6 and l OYR 6/8 light silty clay loam, weak medium
III
BCt
26-34
subangular blocky structure, friable, few roots
8YR 5/6 and IOYR 6/8 silt loam, structureless-massive.
III
C
34-85
friable, few roots
Heltzel Soil Consulting, LLC
Page (o of
Abbreviated Design - TU Effluent with Trenches
Site 8A-1 Albemarle County PRIMARY
A
a. Estimated percolation rate. (minutes per inch)
75
b. Recommended trench bottom. inches
20
c. Depth to impervious strata/ or water table/ or limit of evaluation.
(inches)
so
so
60
d. Minimum separation distance required. inches
18
12
24
e. Separation distances in inches provided in design.
40
40
40
f. Sloe (percentage)
14
g. Minimum trench bottom due to slo e . (inches)
13
h. Is the slope greater than orequal to 10%?
Yes
i. If Ai is Yes, does 24 inches or greater to rockrimpervious strata exist below
Ab?
Yes
j. If yes to Aj, add 1 ft. to the minimum center -to -center spacing beginning at 20%
slope and continue for each 10% slope increase above 20%. If no to Aj, add 1 ft to
the minimum center -to -center spacing beginning at 10% slope and continue for each
10% slope increase above 10%. (Report the value, in feet, of the increase in center -to -
center spacing above the minimum).
6
e
a.Design Type?
n3
b.Trench bottom square feet required loading rate, gpdtft2
0.59
c.
a. Number of bedrooms.
5
b. Gallons per day in design
750
D.
a. Length of trench. feet
100
b. Length of available area. (feet)
100
E.
Width of trench. feet
3
F.
I Number of trenches.
5
G.
Center-to-centerspacing. (feet)
9
H.
a. Width required. feet
39
b. Width of available area. (feet)
70
I.
Trench bottomsquare footage required.
1271
,t.
Trench bottomsquare footage in design.
1500
K.
a. Is a reserve area required? Yes
X No
b. Percent required
100%
c. Percent available
100%
Notes:
Heltzel Soil Consultinq, LLC
Page I of 4
Abbreviated Design - TU Effluent with Trenches
Site 7A-1 Albemarle County RESERVE
A.
a. Estimated percolation rate. (minutes per inch)
75
b. Recommended trench bottom. inches
15
c. Depth to impervious strata/ or water table/ or limit of evaluation.
Inches
32
32
32
d. Minimum separation distance required. inches
is
12
24
e. Separation distances in inches provided in design.
17
17
17
f. Sloe (percentage)
13
Minimum trench bottom due to slope. inches
12.5
h. Is the sloe greater than orequal to 10%?
Yes
i. If Ai is Yes, does 24 inches or greater to rocklimpervious strata exist below
Ab?
No
j. If yes to Aj, add 1 ft. to the minimum center -to -center spacing beginning at 20%
slope and continue for each 10% slope increase above 20%. If no to Aj, add 1 ft. to
the minimum center -to -center spacing beginning at 10% slope and continue for each
10% slope increase above 10%. (Report the value, in feet, of the increase in center -to -
center spacing above the minimum).
1
B.
a. Design Type?
TU
b.Trench bottomsquare feet required loading rate, pd/f12
0.58
c.
a. Number of bedrooms.
5
b. Gallons per day in design
750
D.
a. Length of trench. feet
100
b. Length of available area. (feet)
100
E.
1width of trench. feet
3
F.
I Number of trenches.
5
G.
Center-to-centerspacing. feet
10
H.
a. Width required. feet
43
b. Width of available area. Meet
I.
Trench bottomsquare footage required.
1271
J.
Trench bottomsquare footage in design.
1500
K.
a. Is a reserve area required? Yes
X I No
b. Percent required
100%
c. Percent available
100%
Notes:
Heltzel Soil Consulting, LLC
1412 Saumsville Road, Maurertown, VA 22644
103'
1
SrrE sat
October 24, 2022
DRAWN BY: CSH
SITE 8A-1 & 7A-1 SKETCH
TM # 69-50B
ALBEMARLE COUNTY, VA
SrrE 8A-1
*P5
P2;
♦P5
100.00,
lllc�
WELL AREA
�44'
♦ .SOS
Pi �149' -�
SITE 7A-1 P2'
0
Page qof Q
9
/il
Heltzel Soil Consulting, LLC
1412 SaumsviAe Road, MaureRown, VA 22644
11
[19B
OT 1
RE
6'
DRAINFIELD LOCATION SKETCH
TM # 69-50B
ALBEMARLE COUNTY, VA
=&i
SM 8M1
October 28, 2022
DRAWN BY: CSH
REVISED
T.M.69-50B
8.73 ACRES
ioo.oa
me
VMLL AREA
#17
Page`1 ofQ I
VDH
.-MONUM
FOUN
VD H
JNUMENT
FOUND
VIRGINIA VXDHOF HEALTH DEPARTMEHT
Protecting You and Your Environment
Sewage Disposal Certification Letter Approval
December 7, 2022
Stockton Creek, LLC
C/O Alan Taylor
455 Second Street SE, #201
Charlottesville, VA 22902
RE: Tax Map: 69-50B (Site 7B-1 & 8B-1))
HDID:101-22-0398
Page I of 3
Albemarle County Health Department
1138 Rose Hill Drive
Charlottesville, VA 22903
(434)972-6219 Voice
(434)9724310 Fax
APPROVED
Important Note: Certification Letter Approval for Site DF 7B-1 & 811-1
Dear Alan Taylor,
This Certification Letter is issued in lieu of a sewage disposal system construction
permit in accordance with §32.1-163, et seq., of the Code of Virginia. The Board of Health
hereby recognizes that the soil and site conditions acknowledged by this correspondence, and
documented by additional records on file at the local health department, are suitable for the
installation of an onsite sewage disposal system. The attached plat shows the approved area for
the sewage disposal system. This letter is valid until a permit for construction is issued and the
system is installed, inspected and approved. This letter is void if there is any substantial physical
change in the soil or site conditions where the sewage disposal system is to be located.
The application for a certification letter was submitted pursuant to § 32.1-163.5 of the
Code of Virginia which requires the Health Department to accept private soil evaluations and
designs from an Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation
with an OSE for residential development. The site for an individual onsite sewage system was
certified as being in compliance with the Board of Health's regulations by: Chris Heltzel,
AOSE License 1940001460. This letter is issued in reliance upon that certification.
A permit to construct the sewage disposal system must be issued before construction of
the system. If the property owner (current or future) applies for a construction permit within 18
months of the date of this letter, the application fee paid for this letter shall be applied to any
state fees for a permit to construct a sewage disposal system. After 18 months, the applicant is
responsible for paying all state fees for a permit application.
Tax Map: 69-50B (Site DF 7B-1 & 8B-1)
HDID: 101-22-0398
Page 2 of 2
This letter, and accompanying plat of survey showing the specific location of the sewage
disposal system area and well area (if applicable), may be recorded in the land records by the
clerk of the circuit court in the jurisdiction where all or part of the site or proposed site of the
system is to be located. The site shown on the plat is specific and must not be disturbed or
encroached upon by any construction. To do so voids this letter. Upon the sale or transfer of the
land that is the subject of this letter, the letter shall be transferred with the title to the property.
Future owners are advised to review the plat for the location of the onsite sewage disposal area to
make sure their building plans do not interfere with the area. If they have any questions
regarding the location of the area, they should contact the local health department for assistance.
The area evaluated, and certified by this letter, is suitable to accommodate a 5 bedroom
house using a system design of 750 gallons per day. The property- will be served by a Private
water supply as shown on the attached plat. Owners are further advised that when connection to
a public water system is proposed and the public water system has reached its permitted capacity,
a permit for construction may not be issued until such time that a connection is approved and
available for use.
This letter is an assurance that a sewage disposal system construction permit will be
issued (provided there have been no substantial physical changes in the soil or site conditions
where the system would be located); however, it is not a guarantee that a permit for a specific
type of system will be issued. The design of the sewage system will be determined at the time of
application for a building permit and sewage system construction permit. The design will be
based on the site and soil conditions certified by this letter, structure size and location, water well
location (final determination to be made at time of permit issuance), the regulations in effect at
the time, and any off -site impacts that may have occurred since the date of the issuance of this
letter. In some cases, engineered plans may be required prior to issuance of the construction
permit. In accordance with § 32.1-164.1:1 of the Code of Virginia, owners are advised to apply
for a sewage disposal construction permit only when ready to begin construction.
This certification letter approval has been issued in accordance with applicable
regulations based on the information and materials provided at the time of application. There
may be other local, state, or federal laws or regulations that apply to the proposed construction of
this onsite sewage system. The owner is responsible at all times for complying with all
applicable local, state, and federal laws and regulations. if you have any questions, please contact
me.
Issued by:
4 /
JoOfKirtley
Environmental Health Technical Consultant
COMMONWEALTH OF VIRGINIA
Application for. E Sewage System ❑ Water Supply
Owner. Stockton Creek LLC c/o Alan Taylor
Mailing Address: 466 Second Street SE, # 201
Charlottesville, VA 22902
Agent Stockton Creek LLC c/o Alan Taylor
Mailing Address: 456 2nd Street SE, Sune 201 Charlottesville, VA 22902
Site Address: TOD
VA 22920
Directions to Property:
VDH USE ONLY
Health Dept IDa 1I? �ZZ'Q )Q
Due Date:
Phone; 6124264728
Fax:
Phone:
Phone: 434-981-3634
Fax:
Email: simpeon@aUe nsbvcaonmanagememeom
Subdivision: DF 7113•1 8: 88•1 Section: Block: Lot:
Tax Map: 69-50B Other Property Info: Acreage: 8.73
Sewage system
Type of Approval: Applicants for new construction are advised to apply for a certification letter to determine If the land Is suitable for
a sewage
system and to apply for a construction permit (valid for 19 months) only when ready to build.
121 Certification Letter ❑ Construction Permit ❑ Subdivison Approval ❑
Repair
Proposed Use:
Single Family Home (Number of Bedrooms) 5 Multifamily Home (Total # of Bedrooms)
Other (Describe):
Basement El Yes Walk -Out Basement? Yes Fixtures in Basement? I]
Yes
❑ No ❑ No ❑
No
Conditional Permit Desired? ❑ Yes No If yes, what type of conditions are desired?
❑ Reduced Water Flow ❑ Limited Occupancy ❑ Intermittent or seasonal use ❑ Temporary Use (1 yr. maximum)
Do you wish to apply for a betterment loan eligibility letter ❑ Yes" 0 No
"There is a $50 fee for determination of eligibility.
Water Supply
Will the water supply be ❑ Public or Private Is the water supply ❑ Existing or [D Proposed
If proposed, Is this a replacement well? ❑ Yes El No If yes, will the old well be abandoned? ❑ Yes
❑ No
Will any buildin s within 50` of the well be termite treated? ❑ Yes ❑' No
All Applicants
Is this a private sector OSE/PE application? Yes ❑ No If yes, Is the OSE package attached?
Yes
❑ No
Is the property Intended to serve as your (the owners) principal place of residence? ❑ Yes I] No
In order for VDH of process your application for a sewage system, you must attach a plat of the property and a site sketch. For water suoolies. a
purr ur ure property is recommenoea ana a site sxetcn IS required. The site sketch should show your property lines, actual and/or proposed
buildings, and the desired location of your well and/or sewage system. When the site evaluation Is conducted, the property lines, building locetion
and the pro sites must be cleariy.,narked and the property su8identty visible to see the topography.
I give iiwkn to the Virgintlmerlt of Health to enter onto the property described during normal business hours for the purpose of
pro this application a d rrn quality assurance checks of evaluations and designs oeditd by a private sector Onshe Soil Evaluator
ur P lonal ntii the sews disposal sysrem and/or private water supply has been constructed and approved.
C HELT,
VicNa.19400L^1450 1
v
�o(Zg (22
Sgnatu (qme t _ a� _ Date
leer. •rrr•�sr+w�rr.y..+assw. W I,sar.ar.errrr.r�•a rrrrrwn
vrxa L mot. V40111111eer•d: Do, Dw
Yeob_,,,,_HDZDS A4pnaw most 1
fft=ot"Otbed0 i3HA4 Ra**1
Page of 1
❑ Construction Permit ❑ Repair
Permit
OSEIPE Report For:
❑ Voluntary Upgrade
Permit
El Certification
Letter
❑ Subdivision Approval
Property Location:
911 Address: TBD City State, Zip: Alton, VA 22920
Lot: Section: Subdivision: DF78-1 & 6&1
GPIN or Tax Map M 69-50B Health Dept. ID #:
Latitude. Longitude:
Owner
Name: Stockton Creek LLC c/o Alan Taylor
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Prepared by:
OSE Name: Chris Haltzel License # 191&001460
Address: PO Box 554, Woodstock, VA 22664
PE Name: License #
Address:
Date of Report: 10/2&2022 Date of Revision #1:
Date of Revision #2:
ContentsRndex of this report:
1. Cover Sheet 8. Site Sketch
2-3. Soli Summaries 9. Dralydleld Location & Sanitary Survey
4 5 Profiles
6-7. Abbreviated Desf ns
Certification Statement
1 hereby certify that the evaluations and/or designs contain herein were conducted in accordance with the applicable provisions of the
Sewage Handling & Disposal Regulations (12VAC5-610), the Private Well Regulations (12VAC5-630), the Regulations forARematim Onsite
Systems (12VAC5-613) and all other applicable laws, regulations, and policies implemented by the Virginia Department of Health. I further
certify that I currently posses any professional license required by the laws and regulations of the Commonwealth that have been duly issued
by the applicable agency cha h licensure to perform the work contained herein. The potenttai for both conventional and afttemative
onsite sewage systems h with the owner/applicant.
❑ The r In
to this co�vJ�r page has been conducted under an exemption to the practice of engineering, specifically the
exe { In Code of Virginia n 54.1-402.A.11
am S7L7PHER S. 'Z
I recommend that . UO ❑ Coryp@U Permit, ❑ Subdivision Approval be: ❑' issued
rE�i6flBdli�I�QE`} $ Repair Permit ❑ Voluntary Upgrade ❑ Denied
08EIPE 3lgnaturo. 9�EONrrrc e0��'Date: `0(1
The r0mr Contains personal information subject to disclosure under the Freedom of Information Act Revised 12,V I/14
Page 2 of
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 9/1012021 Submitted to: Albemarle County Health Department
Owner: Stockton Creek LLC c/o Alan Taylor Telephone Number. 512-426-4728
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: Stockton Creek LLC do Alan Taylor Address: 455 2nd Street SE, Suite 201 Chadobtesville, VA 22902
Property Location: TBD Tax Map/GPIN: 69-50B
Subdivision: Blk/Sec: Site: 813-1
1. Position in Landscape Satisfactory: 0 Yes ❑ No
Describe: Convex Upland Sideslo e
2. Slope: 14 %
3. Depth to Rock or Impervious Strata: Max. 61+" Min. 32" None ❑
4. Depth to seasonal water table (gray mottling or gray color): Not Observed ❑ Yes g 32"
5. Free Water Present? (D No ❑ Yes Range: inches
6. Soil Percolation rate estimated: 0 Yes Texture Group: I ❑ II ❑ III Rl IV ❑
❑ No Estimated rate: 75 mpi @ 15"
7. Permeability Test Performed? F1 No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
E Site Approved. Drainfield to be placed at 15 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow,
5 ❑ Insufficient area of suitable soil for drainfeld and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages if necessary)
Additional Notes: PRIMARY
Page 3 of
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 911012021 Submitted to: Albemarle County Health Department
Owner: Stockton Creek LLC c/o Alan Taylor Telephone Number: 512-426-4728
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: Stockton Creek Lac Uo Alan Taylor Address: 455 2nd Street SE, Suite 201 Charlottesrille, VA 22902
Property Location: TBD Tax Map/GPIN: 69-50B
Subdivision: Blk/Sec: Site: 7B-1
1. Position in Landscape Satisfactory: 121 Yes ❑ No
Describe: Convex Upland Sideslope
2. Slope: 13 %
3. Depth to Rock or Impervious Strata. Max. 58"+ Min. None El
4. Depth to seasonal water table (gray mottling or gray color): Not Observed El Yes ❑
5. Free Water Present? I] No ❑ Yes Range: inches
6. Soil Percolation rate estimated: 2 Yes Texture Group: I ❑ II ❑ III D IV ❑
❑ No Estimated rate: 70 mpi @ 3"
7. Permeability Test Performed? 2 No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
21 Site Approved. Drainfield to be placed at 3 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ Insufficient area of suitable soil for drainfield and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages if necessary)
Additional Notes: 100% RESERVE
Address: Stockton Creek
P1
P2
P3
P4
P5
?) 4oFg
Heltzel Soil dal Date: 9/10/2021
Consultlna Drainfield:e& I
Ap
0-10 .. u"Ju uun:ay auu� fuse,
III
friable, many roots
Bt
10-27 8YR 5/6 clay loam, moderate medium subangular blocky
structure, friable, common roots,
III
C
27-56 5YR 5/8 and 1 OYR 6/8 light silty clay loam, st mchlreless-
massive, friable, few roots, 5% cobbles
III
Ap
0-6 10YR 4/3 silt loam, weak fine subangular blocky structure,
friable, many roots
Bt
6-34 5YR 5/6 clay loam, moderate medium subangular blocky
structure, friable, common roots, 5% cobbles
5YR 5/6 silty clay loam, weak coarse subangular blocky
BCt
34-43 structure, friable, common roots, 5% cobbles, common
III
10YR 6/6 parent material mottles
Ct
43-61 SYR 5/8 and 1 OYR 6/8 light silty clay loam, structureless-
massive, friable, few roots, 5% cobbles
III
Ap
10YR 4/3 silt loam, weak fine subangular blocky structure,
0-9friable,
many roots
III
Bt
8-28 SYR 8/6 clay loam, moderate medium subangular blocky
structure, friable, common roots,
III
C
28-80 5YR 5/8 and IOYR 6/8 light silty clay loam, structureless-
III
massive, friable, few roots, 5% cobbles
Apl
0-8 10YR 4/3 silt loam, weak fuze subangular blocky structure,
III
very friable, many roots
Apt
8-14 10YR 3/3 silt loam, weak fine subangular blocky structure,
III
friable, many roots
Bt
14-32 7.5YR 5/8 clay loam, moderate medium subangular blocky
structure, friable, common roots
Ill
C 3MO 7.5YR 8/6 and 1 OYR 5/6 silty clay loam, structureless- III
massive, friable, few roots, few 1 OYR 6/2 iron depletions
Ap 0-8 1 OYR 4/3 silt loam, weak fine subangular blocky structure,
friable, many roots
Btl 8-20 5YR 8/6 silty clay loam, moderate medium subangular III
blocky structure, friable, common roots,
5YR 5/6 silty clay loam, moderate coarse subangular
Bt2 20-44 blocky structure, friable, common roots, few 10YR 6/2 iron III
depletions
C 44-50 5YR 5/6 and IOYR 6/6 silty clay loam, struct reless- III
massive, friable, few roots, few IOYR 6/2 iron depletions
A&Iress: Stockton Creek
P1
P2
P3
P4
P5
Q3 Svk a
8eltael Soil Ebal Date: 9/10/2021
Consultina Drainfield: TB-1
Ap
IOYR 4/3 silt loam, weak medium granular structure,
0 8
III
friable, many roots
Bt
8_27 SYR 6/6 clay loam, strong medium subangular blocky
III
structure, friable, common roots
BCt
27-38 SYR 6/6 and IOYR 6/6 light silty clay loam, weak medium
III
subangular blocky structure, friable, few roots
C
36-58 SYR 5/6 and IOYR 6/8 silt loam, stsuctureless-massive,
friable, few roots
Ap
0-7 IOYR 4/3 silt loam, weak medium granular structure,
ffi
friable, many roots
Bt
Y-86 SYR 8/6 clay loam, strong medium subangular blocky
In
structure, friable, common roots
BCt
25-37 SYR 6/8 and 10YR 6/8 light silty clay loam, weak medium
III
subangular blocky structure, friable, few roots
C
37-56 5YR 5/8 and IOYR 6/8 silt loam, structureless-massive,
III
friable, few roots
Ap
0-9 1 OYR 4/3 silt loam, weak medium granular structure,
III
friable, many roots
Bt
9-27 SYR 5/6 clay loam, strong medium subangular blocky
III
structure, friable, common roots
BCt
27-35 SYR 6/6 and I OYR 6/6 light silty clay loam, weak medium
III
subangular blocky structure, friable, few roots
C
38-85 SYR 8/6 and IOYR 0/8 silt loam, structureless-massive,
M
friable, few roots
A p
0-10 1 OYR 4/3 silt loam, weak medium granular structure,
III
friable, many roots
Bt
SYR 6/6 clay loam, strong medium subangular blocky
10-23
III
structure, friable, common roots
BCt
23-31 SYR 6/6 and IOYR 6/6 light silty clay loam, weak medium
subangular blocky structure, friable, few roots
C
31-64 SYR 5/6 and IOYR 6/8 silt loam, structureless-massive,
friable, few roots
Ap
0-8 IOYR 4/3 silt loam, weak medium granular structure,
III
friable, many roots
Bt
8-23 SYR 6/6 clay loam, strong medium subangular blocky
III
structure, friable, few roots
C
SYR 8/6 and 10YR 6/8 silt loam, structureless-massive,
23 52
III
friable, few roots
Heltzel Soil Consulting, LLC
Page � of a
Abbreviated Design - TU Effluent with Trenches
Site 8B-1 Albemarle County PRIMARY
A.
a. Estimated percolation rate. (minutes per inch)
75
b. Recommended trench bottom. (inches)
1s
c. Depth to impervious strata/ or water table/ or limit of evaluation.
inches
32
32
32
d. Minimum separation distance required. inches
18
12
24
e. Separation distances in inches provided in design.
17
17
17
f. Slope (percentage)
14
q. Minimum trench bottom due to slope. inches
13
h. Is the sloe greater than orequal to 10%?
yes
i, If Ai is Yes, does 24 inches or greater to rocktimpervious strata exist below
Ab?
No
j. If yes to Aj, add 1 ft. to the minimum center -to -center spacing beginning at 20%
slope and continue for each 10% slope increase above 20%. If no to Aj, add 1 ft to
the minimum center -to -center spacing beginning at 10% slope and continue for each
10% slope increase above 10%. (Report the value, in feet, of the increase in center -to -
center spacing above the minimum).
1
a
a.Design Type?
rt.3
b.Trench bottomsquare feet required loading rate. /ft2
0.59
c.
a. Number of bedrooms.
5
b. Gallons per day in design
750
D. Ia.
Len th of trench. feet
100
b. Lencith of available area. (feet)
100
E.
Width of trench, (feet)
3
F.
Number of trenches.
5
G.
Center-to-centerspacing. (feet)
10
H.
a. Width required. feet
43
b. Width of available area. feet
46
I. lTrench
bottom square footage required.
1271
i
Trench bottomsquare footage in design.
1500
K.
a. Is a reserve area required? Yes
X No
b. Percent required
100%
c. Percent available
100%
Notes:
Heltzel Soil Consulting LLC
Abbreviated Design -TL3 to Drip Disposal
Site 7B-1 Albemarle County RESERVE
Page of O�
A.
Ia. Estimated percolation rate. (minutes per inch)
70
b. Recommended drip tubing installation. (inches)
3
c. Depth to impervious strata/ or water table/ or limit of evaluation. (inches)
58
58
58
d. Minimum separation distance required. (inches)
18
12
24
e. Separation distances in inches provided in design.
55
55
55
f. Slope (percentage)
13
g. Is the slope greater than 10, 20 or 30%?
Yes
I. If Ag is Yes, does 24 inches or greater to rocklimpervious strata exist
below Ab?
Yes
B.
a.Design Type?
TL3
b.Soil Loading Rate, gpd1ft2
0.24
C.
a. Number of bedrooms.
5
b. Gallons per day in design
750
D.
a. Length of run. (feet)
100
b. Length of available area. (feet)
100
E.
Width of drip tubing. (inch)
1
F. I
Number of runs.
18
G.
Center -to -center spacing. (feet)
2
H.
a. Width required, feet
35
b. Width of available area. (feet)
40
I.
a. Total square footage required
3125
b. Totalsquare footage in design
3500
J.
a. Linear feet of drip tubing required
1563
b. Linear feet of drip tubing provided
1750
K.
a. Is a reserve area required? Yes
X
No
b. Percent required
100%
c. Percent available
100%
Notes: Design is for 100% Reserve
Heltzel Soil Consulting, LLC
1412 Saumsv7le Road, Maursdown, VA 22644
rol
1
1021
�P4
SITE 86-1 & 76-1 SKETCH
TM # 69-50B
ALBEMARLE COUNTY, VA
SITE 8A-1
100.00r
401
PS
SITE 8B-1 / V SITE 7A-1
October 24, 2022
DRAWN BY: CSH
WE 7B-1
'P4IP
2♦
44'/�T
Page V of q
mc�
WELL AREA
L
Heltzel Soil Consultinq, LLC
1412 Saumsvflle Road, Maumdown, VA 22544
M
11
ao
-19B
_OT 1
;RES
36'
October 28, 2022
DRAWN BY: CSH
DRAINFIELD LOCATION SKETCH
TM # 69-50B
ALBEMARLE COUNTY, VA
REVISED
T.M.69-50B
8.73 ACRES
#17
WELL ARBA
ILE
IEL #18 /
WUL AaHA
Page of L
VDH
lsl' MONUM
r
FOUN
VD H
MONUMENT
FOUND
O' BO' 160' 840'
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
LOT 6
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
T.M.69-6M
REVISED LOT 7
E.C.ACKERMAN TRUST
D.B.4733-23
D.B.4733-20 & 21 PLAT
D.B.4456-444
D.B.3530-234 PLAT
PROPOSE[
STOCKTON CREEKS
S
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
(30'PRESCRIPTIVE EASEMENT)
EXISTING
STOCKTON CREEK S
ST.RT.7;
T.M.69-19
REN.03+ST LO
11
RGINIA
UYTHOFIHEALTH DEPARTMENT
Protecting You and Your Environment
Sewaae Disposal Certification Letter Approval
November 28, 2022
Stockton Creek, LLC
C/O Alan Taylor
455 Second Street SE, #201
Charlottesville, VA 22902
RE: Tax Map: 69-19C (Site 12-1)
HDID: 101-22-0401
Page I of 3
Albemarle County Health Department
1138 Rose Hill Drive
Charlottesville, VA 22903
(434) 972-6219 Voice
(434) 972-43 10 Fax
APPROVED
Important Note: Certification Letter Approval for Site DF 12-1
Dear Alan Taylor,
This Certification Letter is issued in lieu of a sewage disposal system construction
permit in accordance with §32.1-163, et seq., of the Code of Virginia. The Board of Health
hereby recognizes that the soil and site conditions acknowledged by this correspondence, and
documented by additional records on file at the local health department, are suitable for the
installation of an onsite sewage disposal system. The attached plat shows the approved area for
the sewage disposal system. This letter is valid until a permit for construction is issued and the
system is installed, inspected and approved. This letter is void if there is any substantial physical
change in the soil or site conditions where the sewage disposal system is to be located.
The application for a certification letter was submitted pursuant to § 32.1-163.5 of the
Code of Virginia which requires the Health Department to accept private soil evaluations and
designs from an Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation
with an OSE for residential development. The site for an individual onsite sewage system was
certified as being in compliance with the Board of Health's regulations by: Chris Heltzel,
AOSE-License 1940001460. This letter is issued in reliance upon that certification.
A permit to construct the sewage disposal system must be issued before construction of
the system. If the property owner (current or future) applies for a construction permit within 18
months of the date of this letter, the application fee paid for this letter shall be applied to any
state fees for a permit to construct a sewage disposal system. After 18 months, the applicant is
responsible for paying all state fees for a permit application.
Tax Map: 69-19C (Site DF 12-1)
HDID:101-22-0401
Page 2 of 2
This letter, and accompanying plat of survey showing the specific location of the sewage
disposal system area and well area (if applicable), may be recorded in the land records by the
clerk of the circuit court in the jurisdiction where all or part of the site or proposed site of the
system is to be located. The site shown on the plat is specific and must not be disturbed or
encroached upon by any construction. To do so voids this letter. Upon the sale or transfer of the
land that is the subject of this letter, the letter shall be transferred with the title to the property.
Future owners are advised to review the plat for the location of the onsite sewage disposal area to
make sure their building plans do not interfere with the area. If they have any questions
regarding the location of the area, they should contact the local health department for assistance.
The area evaluated, and certified by this letter, is suitable to accommodate a 5 bedroom
house using a system design of 750 gallons per day. The property will be served by a Private
water supply as shown on the attached plat. Owners are further advised that when connection to
a public water system is proposed and the public water system has reached its permitted capacity,
a permit for construction may not be issued until such time that a connection is approved and
available for use.
This letter is an assurance that a sewage disposal system construction permit will be
issued (provided there have been no substantial physical changes in the soil or site conditions
where the system would be located); however, it is not a guarantee that a permit for a specific
type of system will be issued. The design of the sewage system will be determined at the time of
application for a building permit and sewage system construction permit. The design will be
based on the site and soil conditions certified by this letter, structure size and location, water well
location (final determination to be made at time of permit issuance), the regulations in effect at
the time, and any off -site impacts that may have occurred since the date of the issuance of this
letter. In some cases, engineered plans may be required prior to issuance of the construction
permit. In accordance with § 32.1-164.1:1 of the Code of Virginia, owners are advised to apply
for a sewage disposal construction permit only when ready to begin construction.
This certification letter approval has been issued in accordance with applicable
regulations based on the information and materials provided at the time of application. There
may be other local, state, or federal laws or regulations that apply to the proposed construction of
this onsite sewage system. The owner is responsible at all times for complying with all
applicable local, state, and federal laws and regulations. If you have any questions, please contact
me.
Issued by:
J h Kirtley
Environmental Health Technical Consultant
COMMONWEALTH OF VIRGINIA
Application for. 0 Sewage System ❑ Water Supply
Owner: Stockton Crook LLC do Alan Taylor
Mailing Address: 488 Second Street SE, # 201
Charlottesville, VA 22902
Agent: Stockton Creak LLC do Alen Taylor
Mailing Address: 486 2nd Streat BE, Suite 2o1 Charlottesville, VA 22902
Site Address, TBD
Afton, VA 22920
Directions to Property:
VDH USE ONLY
Health Dept IDO 6t-ZZ-(11
Due Date:
Phone: 512-4264728
Fax:
Phone:
Phone: 484-981-3eU
Fax:
Email: aimpsor@atleseauavctlonmanep mg cam
Subdivision: DF 12.1 Section: Bloch: Lot
Tax Map: 69-19C Other Property Info: Acreage: 7.7
Sewage System
Type of Approval: Applicants for new construction are advised to apply for a certification letter to determine if the land is suitable for a sewage
system and to apply for a construction permit (valid for 18 months) only when ready to build.
I] Certification Letter ❑ Construction Permit ❑ Subdivison Approval Cl Repair
Proposed Use:
Single Family Home (Number of Bedrooms) 8 Multifamily Home (Total # of Bedrooms)
Other (Describe):
Basement ❑ Yes Walk -Out Basement? ❑ Yes Fbdures In Basement? ❑ Yes
❑ No ❑ NO ❑ No
Conditional Permit Desired? ❑ Yes No If yes, what type of conditions are desired?
❑ Reduced Water Flow ❑ Limited Occupancy ❑ Intermittent or seasonal use ❑ Temporary Use (1 yr. maximum)
Do you wish to apply for a betterment loan eligibility letter? ❑ Yes" 0 No
"There Is a SW fee for determination of alimbilihv_
Will the water supply be ❑ Public on 0 Private is the water supply ❑ Existing or ❑' Proposed
If proposed, Is this a replacement well? ❑ Yes 10 No If yes, will the oil well be abandoned? ❑ Yea ❑ No
Will any buildtngs within W of the well be termite treated? ❑ Yes No
AN Applicants
Is this a private sector OSE/PE application? (] Yes ❑ No If yes, Is the OSE package attached? l] Yes
❑ Is the property intended to serve as your (the owners principal place of rasidence7 ❑ Yes 0 No No
In order for VDH of process your application for a sewage system, you must attach a plat of the property and a site sketch. For water supplies, a
plat of the property Is recommenced and & site sketch is required. The site sketch should show your property lines, actual and/or proposed
buildings, and the desired location of your well and/or sewage system. When the site evaluation Is conducted, the property Imes, building location
— and the proposed well and sewage sites must be clearly marked and the prop" suMcW* visible to see the topography.
r,lneeras
Depwriment Of Haaml to error onto the property described durkV normal business hours for the purpose of
prperform quality assurance chec s of evaluations and designs certified by a private sector Onshe Soil Evaluator
or until the sewage disposal system and/or private water supply has been constru ted end approved.
TZEL 5100
Date
O\'SI?E. SO" w.utr�srrMlwwa+swabr�aM��e•irra�lYri.lrr.rr4a 11w�r srawr
10N441tYatilhn1lax Des Brdkv&�Vsat=i
FaaS_ fm i rf Flasnald most
Fty>zsnt4'DdaAeoklf BiW# Reeefptt
Page of
OSEIPE Report For:
❑ Construction Permit ❑ Repair ❑ Voluntary Upgrade 1Z Certification ❑ Subdivision Approval
Permit Permit Letter
rroperty Location:
111 Address: TBD City, State, Zip: Afton, VA 22920
ot: Section: Subdivision: DF 12-1
'PIN or Tax Map 69-19C Health Dept. ID #
Latitude: Longitude
Name: Stockton Creek LLC do Alan Taylor
Address: 455 Second Street SE, # 201 Cherfottesvi0e, VA 22902
Prepared by:
OSE Name: Chris Hertel License # 1940-001400
Address: PO Box SS4, Woodstock, VA 22664
Name:
Date of Report: 1012012022 Date of Revision #1:
1. Cover Sheet
Sol/
of this report:
statement
Data of Revision #2:
6, Site Sketch
7. DralrrfleW Location & Santtary Survey
License #
I hereby certify that the evaluations and/or designs contain herein were conducted In accordance with the applicable provisions of the
Sewage Handling & Disposal Regulations (12VACS-610), the Private Well Regulations (12VAC5.6W), the Regulations for AllematW Onsite
Systems (12VAC"13) and all other applicable laws, regulations, and policies implemented by the Virginia Department of Health. I further
certify that I currently posses any professional license required by the laws and regulations of the Commonwealth that have been duly Issued
by the applicable agency charged with Iicensure to perform the work contained herein. The potential for both Conventional and alternative
Dnste sewage systems has been discussed with the owner/applicant.
o The
recommend
cover page has been conducted under an exemption to the practice of engineering, specifically the
iLnis Section 64.1-402A.11
F ❑ Construc ion P
*Ot"�bn La e
Nr6-//..0 R S. 7
Lie NO. lWirlyi14�n s
❑ Subdivision Approval be: E /sued
❑ Repair Permit ❑ Voluntary Upgrade ❑ Dented
t c�l2a(Z 2
Date:
SO11
The form contains personal rnformetion subject to dsdosure under the Freedom of information Act RaLde 4 4=414A
Page ? of 7
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 9/8/2021 Submitted to: Albemarle County Health Department
Owner Stockton Creek LLC Go Alan Taylor Telephone Number. 512-426-4728
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: stodRon Creep LLC No Alan Taylor Address: 455 2nd sheet SE, suBe 20+ chadoltew1b, VA 22902
Property Location: TBD Tax Map/GPIN: 69-19H
Subdivision: Slk/Sec: Site: 12-1
1. Position in Landscape Satisfactory: 0 Yes ❑ No
Describe: Convex Upland Sideslope
2. Slope: 15-16 %
3. Depth to Rock or Impervious Strata: Max. 6811+ Min. None 121
4. Depth to seasonal water table (gray mottling or gray color): Not Observed El Yes ❑
5. Free Water Present? O No ❑ Yes Range: inches
6. Soil Percolation rate estimated: l] Yes Texture Group: 1 ❑ 11 Q cal ❑ ry ❑
❑ No Estimated rate: 40 mpi @ 40"
7. Permeability Test Performed? 0 No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
O Site Approved. Drainfield to be placed at 40 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
— 4-0- Rates of absorption too slow.
5 ❑ Insufficient area of suitable soil for dralnfield and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages if necessary)
Addltfonal Notes:
Address: Stockton Creek
PI
P2
P3
P4
P5
P' 3 041
Reltael Soil xv 1 Rate,• 09/08/21
COnsnitiaQ Araingeld• 12-1
Ap
0-6 'v An :. J avam, wetM mecuum granular structure, very
II
friable, many roots
Bt
6-20 7'SYR 5/6 sandy clay loam, weak medium subangular
blocky structure, friable, common roots
II
7.5YR 5/8 and l OYR 8/1 sandy loam, structurelese-massive,
C
20-68 very friable, few roots, common 7.SYR 6/6 parent material
II
mottles
Ap
0-7 lOYR 4/3 loam, weak medium granular structure, very
friable, many roots
II
Bt
7-22 5YR 8/6 light sandy clay loam, weak medium subangular
blocky structure, friable, common roots
II
7.SYR 6/8 and l OYR 8/1 sandy loam, structureless-massive,
C
22-65 very friable, few roots, common 7.5YR 6/6 parent material
II
mottles
Ap
0.8 IOYR 4/3 loam, weak medium granular structure, very
friable, many roots
II
Bt
6-28 7.8YR 8/6 sandy clay loam, weak medium subangular
blocky structure, friable, common roots
II
7.8YR 5/6 light sandy clay loam, weak fine subangular
BCt
2841 blocky structure, very friable, common roots, common
II
IOYR 8/1 lithochromic mottles
7.3YR 5/8 and IOYR 8/1 sandy loam, struct reless-massive,
C
31-66 very friable, few roots, common 7.6YR 6/6 parent material
II
mottles
Ap
0-8 IOYR 4/3 loam, weak medium granular structure. very
friable, many roots
II
Bt
6-27 SYR 5/6 sandy clay loam, weak medium subangular blocky
structure, friable, common roots
II
7.6YR S/6 light sandy clay loam, weak fine subangular
BCt
22-34 blocky structure, very friable, common roots, common
II
IOYR 8/1 lithochromic mottles
7.SYR 5/8 and IOYR 8/1 sandy loam, slructureless-massive,
C
34-68 very friable, few roots, common 7.SYR 6/6 parent material
II
mottles
Ap
0-6 1OYR 4/3 loam, weak medium granular structure. very
friable, many roots
II
Bt
6-23 BYR 5/6 sandy clay loam, weak medium subangular blocky
structure, friable, common roots
II
7.8YR 6/8 and l OYR 8/1 sandy loam, stsuctureless-massive,
C
23-66 _ very friable, few mots, common 7.SYR 6/6 parent material -
mottles
Heltzel Soil Consulting
Abbreviated Design -Conventional
Site 12-1 Albemarle County PRIMARY
Page A of 1
A.
a. Estimated percolation rate. minutes per Inch
40
b. Recommended trench bottom. inches
40
c. Depth to impervious strata/ or water table/ or limit of evaluation.
inches
58
58
58
d. Minimum separation distance required. inches
18
18
24
e. Separation distances in inches provided in design.
28
28
28
f. Sloe ercenta a
1s
Minimum trench bottom due to slope. (inches)
22
h. Is the slope reater than orequal to 10%?
yes
I. If Ai is Yes, does 24 inches or greater to rocktimpervious strata exist below
Ab?
Yes
j. If yes to Aj, add 1 ft. to the minimum center -to -center spacing beginning at 20%
slope and continue for each 10% slope Increase above 20%. if no to Aj, add 1 ft to the
minimum center -to -center spacing beginning at 10% slope and continue for each 10%
slope Increase above 10%. (Report the value, in feet, of the increase in center-tosznter
spacing above the minimum).
0
B.
Trench bottomsquare feet required per bedroom able 5.4
314
C.
a. Number of bedrooms.
5
b. Gallons per day in design
750
D.
a. Length
of trench.
feet
100
b. Length of available area. feet
100
E.
Width of trench. feet
3
F.
Number of trenches.
5
G.
Center -to -Centers acin feet
g
H.
a. Width required. feet
48
b. Width of available area. feet
81
1.
Trench bottomsquare footage required.
1570
J.
Trench bottom square Wage in design.
1000
K I
Is a reserve area required? Yes
x INo
Ia.
Percent required?
100%
b. Percent available,
100%
Notes: "See attached abbreviated design form for reserve`*
Heltzel Soil Consulting, LLC
Page S of -7
Abbreviated Design - TO Effluent with Trenches
Site 12-1 Albemarle County RESERVE
A.
a. Estimated percolation rate. minutes per inch
40
b. Recommended trench bottom. inches
40
c. Depth to impervious strata/ or water table/ or limit of evaluation.
inches
68
88
Be
d. Minimum separation distance required. inches
18
12
24
e. Separation distances in inches provided in design.
28
28
28
f. Sloe (percentage)
78
Minimum trench bottom due to slo e , inches
14
h. Is the sloe qreater than orequal to 10%?
Yes
i. If Ai is Yes, does 24 inches or greater to rocktirnpervious strata exist below
AV
yes
j. If yes to Aj, add 1 ft. to the minimum center -to -center spacing beginning at 20%
slope and continue for each 10% slope increase above 20%. If no to Aj, add 1 ft. to
the minimum center -to -center spacing beginning at 10% slope and continue for each
10% slope increase above 10%. (Report the value, in feet, of the increase in center -to -
center spacing above the minimum).
0
t3
a.Design Type?
TL3
b.Trench bottomsquare feet required loading rate, /ft2
1.11
C.
a. Number of bedrooms.
5
b. Gallons per day in design
750
D.
a. Length of trench. feet
100
b. Length of available area. feet
100
E.
Width of trench. feet
3
F.
Number of trenches.
3
G.
Center-to-centerspacing. feet
8
H.
a. Width required. feet
21
b. Width of available area, feet
81
i.
Trench
bottoms uare footage required,
678
J.
Trench bottoms uare footage in design.
two
K.
a. is a reserve area required? Yes
X I
No
b. Percent required
100%
c. Percent available
10096
Notes:
Heltzel Soil Consultinq, LLC Page 6 of-?
1412 Ssunw% Road, Maumdawn, VA 22644
SITE 12-1 SKETCH
TM # 69-19C
ALBEMARLE COUNTY, VA
4
� Js
.j
�B% T.M.69-19C
srr>;1zz-z
Wo 'y
B4 n 1
\
0
y�
IT 7
REVISED LOT 21
7.70 ACRES
r P2
P3• SM 12-1
P40
October 20, 2022
DRAWN BY: CSH
Heltzel Soil Consulting, LLC
1412 Saumavflle Road, Mauredown, VA 22644
® BORE #
O PIT#
SLOPE DIRECTION
PROPOSED WELL
DRAINFIELD LOCATION & SANITARY SURVEY
TM # 69-19C
ALBEMARLE COUNTY, VA
171
21
9E
T 4
ES 16
B?
631
#22
19D
October 20, 2022
DRAWN BY: CSH
fWELL AREA
2s7,
100 W
W
466" T.M.69-19C
REVISED LOT 2
7.70 ACRES
ALL KNOWN WELLS
200' OF THE PRUPW I
Page 7 of
13N
m
#20
SITES wr HHN
3 ARE EHO".
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
LOT 6
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
POND
T.M.69-6M
REVISED LOT 7
E.C.ACKERMAN TRUST
D.B.4733-23
D.B.4733-20 & 21 PLAT
D.B.4456-444
D.B.3530-234 PLAT
STATE ROUTE 803
(30'PRESCRIPTIVE EASEMENT)
GOODLOE LANE
T.M.69-6G
LOT 1
FRANK DONLEY &
CARLA DONLEY
D.B.3380-82,
85 & 86 PLAT
VDH MONUMENT
II
Ii
I
I 1
II
II
11
1 I
11
11
II
II'
11
I
II
I
I
11
i
1
I
1
I
i
VDH i
MONUMENT
FOUND
PROPOSI
STOCKTON CREEK
LOi9
x9l KAES
.T
LOTH
�N, LL LII
mrn I
Lm aE
:.»unEE
(6 R oP at
109
VVDHP9�
T LAYOUT
, ALBEMARLE CO, VA
(30'PRESCRIPTIVE EASEMENT)
PIKE ROAD
Yu
APPROAMATE.�'
LOCATION STREAM
. ...............................
a�
VDH
MONUMENT
OVERHEAD
UTILITY
UNES
REVISED
T.M.69-50B
8.73 ACRES
T.M.69-19J
\
ELL an
REVISED LOT 8
V
6.92+/— ACRES
Y1i LLY16
N � ® rr
3
P
e
��
Em
l
0
1 69-19B
VD
REVISED LOT 1
a H°
MO UI
3.84 ACRES
sR
C.
R IN
FENCE EPOST
VOH
MONUMENT
VDH FOUND
NOT TO SCALE
MONVUMENT
FOUND
/ VDH
MONUMENT
FOUND
August 21, 2022
DRAWN BY: SNV
'ANY CUTTING OR FILLING MAY RENDER THE DISPOSAL AREA
UNSUITABLE AND VOID THIS PERMIT"
Drainfield Installer: If you have any question or require minor
adjustments to this design, contact AOSE at numbers at top of this page.
Contact Heltzel Soil Consulting to schedule Pre -Construction meeting
(72-hour notice required)
RGINIA
V/DHOFIHE HEALTH
Protecting You and Your Environment
Sewage Disposal Certification Letter Approval
December 7, 2022
Page I of 3
Albemarle County Health Department
1138 Rose Hill Drive
Charlottesville, VA 22903
(434) 972-6219 Voice
(434) 972-43 10 Fax
Stockton Creek, LLC APPROVED
C/O Alan Taylor
455 Second Street SE, 4201
Charlottesville- VA 22902
RE: Tax Map: 69-19E (Site 122-2)
HDID: 101-22-0405
Important Note: Certification Letter Approval for Site DF 122-2
Dear Alan Taylor,
This Certification Letter is issued in lieu of a sewage disposal system construction
permit in accordance with §32.1-163, et seq., of the Code of Virginia. The Board of Health
hereby recognizes that the soil and site conditions acknowledged by this correspondence, and
documented by additional records on file at the local health department, are suitable for the
installation of an onsite sewage disposal system. The attached plat shows the approved area for
the sewage disposal system. This letter is valid until a permit for construction is issued and the
system is installed, inspected and approved. This letter is void if there is any substantial physical
change in the soil or site conditions where the sewage disposal system is to be located.
The application for a certification letter was submitted pursuant to § 32.1-163.5 of the
Code of Virginia which requires the Health Department to accept private soil evaluations and
designs from an Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation
with an OSE for residential development. The site for an individual onsite sewage system was
certified as being in compliance-with-the-Roard_ofHealth'_s_regulations_by--Chris-Heltzel,
AOSE License 1940001460. This letter is issued in reliance upon that certification.
A permit to construct the sewage disposal system must be issued before constriction of
the system. If the property owner (current or future) applies for a constriction permit within 18
months of the date of this letter, the application fee paid for this letter shall be applied to any
state fees for a permit to construct a sewage disposal system. After 18 months, the applicant is
responsible for paying all state fees for a permit application.
Tax Map: 69-19E (Site 122-2)
HDID: 101-22-0405
Page 2 of 2
This letter, and accompanying plat of survey showing the specific location of the sewage
disposal system area and well area (if applicable), may be recorded in the land records by the
clerk of the circuit court in the jurisdiction where all or part of the site or proposed site of the
system is to be located. The site shown on the plat is specific and must not be disturbed or
encroached upon by any construction. To do so voids this letter. Upon the sale or transfer of the
land that is the subject of this letter, the letter shall be transferred with the title to the property.
Future owners are advised to review the plat for the location of the onsite sewage disposal area to
make sure their building plans do not interfere with the area. If they have any questions
regarding the location of the area, they should contact the local health department for assistance.
The area evaluated, and certified by this letter, is suitable to accommodate a 5 bedroom
house using a system design of 750 gallons per day. The property will be served by a Private
water supply as shown on the attached plat. Owners are further advised that when connection to
a public water system is proposed and the public water system has reached its permitted capacity,
a permit for construction may not be issued until such time that a connection is approved and
available for use.
This letter is an assurance that a sewage disposal system construction permit will be
issued (provided there have been no substantial physical changes in the soil or site conditions
where the system would be located); however, it is not a guarantee that a permit for a specific
type of system will be issued. The design of the sewage system will be determined at the time of
application for a building permit and sewage system construction permit. The design will be
based on the site and soil conditions certified by this letter, structure size and location, water well
location (final determination to be made at time of permit issuance), the regulations in effect at
the time, and any off -site impacts that may have occurred since the date of the issuance of this
letter. In some cases, engineered plans may be required prior to issuance of the construction
permit. In accordance with § 32.1-164.1:1 of the Code of Virginia, owners are advised to apply
for a sewage disposal construction permit only when ready to begin construction.
This certification letter approval has been issued in accordance with applicable
regulations based on the information and materials provided at the time of application. There
may be other local, state, or federal laws or regulations that apply to the proposed construction of
this onsite sewage system. The owner is responsible at all times for complying with all
applicable local, state, and federal laws and regulations. If you have any questions, please contact
me.
Issued by:
/L '--�
sh Kirtley
Environmental Health Technical Consultant
COMMONWEALTH OF VIRGINIA
Application for: 21 Sewage System ❑ Water Supply
Owner Stockton Creak LLC do Alan Taylor
Mailing Address: 456 Second 81reet BE, 0 201
Charlottesville. VA 22902
Agent. Stockton Creek LLC c/o Alan Taylor
Mailing Address 455 2nd Street BE, Suite 201 Charlottesville. VA 22902
Site Address: TBD
Afton, VA 22920
Directions to Property:
Subdivision: DF 122-2
Tax Map: 69-19E
VDH USE ONLY
Health Dept IDuf I G k • ZZ - V-
Due Date:
Phone: 512-4264728
Fax:
Phone:
Phone: 434.881.3634
Fax:
Email: simpsonlitatincorabuctimmanM.com
Section: Block: Lot:
Other Property Info: Acreage: 4.62
Sewage System
Type of Approval: Applicants for new construction are advised to apply for a certification letter to determine 9 the land Is suitable for a sewage
system and to apply for a construction permit (valid for 18 months) only when ready to build.
El Certification Letter ❑ Construction Permit ❑ Subdivison Approval ❑ Repair
Proposed Use:
Single Family Home (Number of Bedrooms) 5 Multifamily Home (Total R of Bedrooms)
Other (Describe):
Basement Yes Walk -Out Basement? Yes Fixtures in Basement? Yes
❑ No ❑ No [; No
Conditional Permit Desired? ❑ Yes Q No If yes, what type of conditions are desired?
❑ Reduced Water Flow ❑ Limited Occupancy ❑ Intermittent or seasonal use ❑ Temporary Use (1 yr. mmdnwm)
Do you wash to apply for a betterment loan eligibility letter? ❑ Yes" 0 No
"There Is a $50 fee for detarminaHnn of alinihilih,
Water Supply
Will the water supply be ❑ Public or Private Is the water guppy ❑ Existing or 0 Proposed
If proposed, is this a replacement well? ❑ Yes No If yes, will the old well be abandoned? ❑ Yea ❑ No
Will any buildings within 6& of the well be termite treated? ❑ Yes 0 No
All Applicants
Is this a private sector OSE/PE application? O Yes ❑ No If yes, Is the OSE package attached? ❑ Yes
is the property Intended to serve as your (the ownersl principal place of residence? ❑ Yes 0 No El No
In order for VDH of process your application for a sewage system, you must attach a plot of the property and a site sketch. For water supplies, a
-•- r �r� •r w • vv.......,1 ne aria axeam snouia snow your property Knee, actual and/or proposed
buildings, and the desired location of your well and/or sewage system. When the she evaluation Is conducted, the property lines, building location
and the propo $swap sites must be dearly marked and the property sufftlenty visible to see the topography.
I giVe �blon to the V ent of Health to enter onto the property described during normal business hours for the purpose or
pro��la epplCedbn and. rm quality assurance checks of evaluations and designs certlled by a private sector Onslte Sol Evaluator
or P Iona? EngInea unfit the sewage disposal system and/or private water supply has been constructed and approved.
TF� ,
♦ S �k1R15��74�
11S LT
e'9a000�a6o t to/22
Slgnaikdi..ow"MW _.I _e ` Date
7ak.e...rrL..sr1..e..grswrrdM/....al.ref.A.+rllr.r.. as ..s.r T•ww,
yns tub adv Dow Roireit. Daft Doe
i�roS IIDID € pkww al soot If
-r r Rma �WW�
❑ Construction Permit ❑ Repair
Permit
OSEIPE Report For:
❑ Voluntary Upgrade
Permit
21 Certification
Letter
Page—L of 6
❑ Subdivision Approval
Property Location:
911 Address: TOD City, State, Zip: Afton, VA 22920
Lot Section: Subdivision: DP 122.2
GPIN or Tax Map #: 09-19E Health Dept. ID #:
Latitude: Longitude:
Owner:
Name: Stockton Creek LLC do Alan Taylor
Address: 455 Second Street SE, # 201 ChadoNesNNe, VA 22002
Prepared by:
OSE Name: Chds Hehzel License # 194"01460
Address: PO Box 554, Woodstock, VA 22664
PE Name: License #
Address:
Date of Repon: 1W2Q/2022 Date of Revision #1:
Date of Revision 02:
CorMertsllndex of thia report:
1. Cover Sheet 5. SRO Sketch
2. Soil Eveluadw S. DraMeld Location 6 Sannary Survey
3. Profiles
4. Abbreviated Design
Certification Statement
I hereby certify that the evaluations and/or designs contain herein were conducted in accordance with the applcable provisions of the
Sewage Handling & Disposal Regulations (12VAC5-610), the Private Well Regulations (12VAC5.630), the Regulations forAftematkre Onsite
Systerns (f2VACS=S13) and all other applicable laws, regulations, and policies implemented by the Virginia Department of Health. I further
certify that I currently posses any professional license required by the laws and regulations of the Commonwealth that have been duty Issued
by the applicable agency charged with ecensure to perform the work contained hereln. The potential for loth conventional and aftemative
onsite sewage systems has been discussed with the owner/applicant.
The� is Cover page has been conducted under an exemption to the practice of engineering, specifically the
ia111 p�� inia Section 54.1-402.A.tt
G
I recomme lglute
a: ❑ Construdidrrfit ElSubdivision Approval be: i] Issued
e5tt ❑ Repair Permit ❑ Voluntary Upgrade ElDenled
K14G�Vr
OSEIPE Si: C Dom:
0
NI�>1l� F rtmSYtt C
Page Z- of 6
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 9/8/2021 Submitted to: Albemarle County Health Department
Owner: Stockton Creek LLC Go Alan Taylor Telephone Number: 512-4264728
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: Stockton Creek LLC do Alan Taylor Address: 455 2nd Street SE, suite 201 Chadotteshmle, VA 22902
Property Location: TBD Tax Map/GPIN: 69-19E
Subdivision: B1k1Sec: Site: 122-1
1. Position in Landscape Satisfactory: O Yes ❑ No
Describe: Convex Upland Sideslo e
2. Slope: 15-17 %
3. Depth to Rock or Impervious Strata: Max. 60"+ Min. None 0
4. Depth to seasonal water table (gray mottling or gray color): Not Observed 2 Yes ❑
5. Free Water Present? 2 No ❑ Yes Range: inches
6. Soil Percolation rate estimated: 2 Yes Texture Group: i ❑ If p III ❑ IV ❑
❑ No Estimated rate: 40 mpi @3 30"
7. Permeability Test Performed? 21 No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
0 Site Approved. Drainfield to be placed at 30 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ Insufficient area of suitable soil for drainfield and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages if necessary)
Additional Notes:
Page 2, of
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 9/8/2021 Submitted to: Albemarle County Health Department
Owner: Stockton Creek LLC c/0 Alan Taylor Telephone Number. 512-426-4728
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: Stoditn Creek LLC do Alan Taylor Address: 455 end Street SE, SWIG 201 Chark*wvft, VA 22902
Property Location: TBD Tax Map/GPIN: 69-19E
Subdivision: Blk/Sec: Site: 13-1
1. Position in Landscape Satisfactory: El Yes ❑ No
Describe: Convex Upland Sidesio e
2. Slope: 15-17 %
3. Depth to Rock or Impervious Strata: Max. 60"+ Min. None I]
4. Depth to seasonal water table (gray mottling or gray color): Not Observed R] Yes ❑
5. Free Water Present? O No ❑ Yes Range: inches
6. Soil Percolation rate estimated: 0 Yes Texture Group: 1 ❑ 11 El 111 ❑ IV ❑
❑ No Estimated rate: 40 mpi @ 30"
7. Permeability Test Performed? i] No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
ED Site Approved. Drainfield to be placed at 30 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suibable soil over hard rock.
3 ❑ insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ Insufficient area of suitable soil for drainfield-and/or reserve area.
6 ❑ Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages If necessary)
Additional Notes:
Address: Stockton Creek
Pi
B2
B3
B4
BS
P33o46
Dwal Date: 10/4/22
DrdnB* , 122-1
Ap
0-6 IV rut 41;5 loam, weak medium granular structure, very
II
friable, many roots
Bt
6-22 7.8YR 8/6 sandy clay loam, weak medium subangular
blocky structure, friable, common roots
II
C
22-68 7.SYR 6/8 sandy loam, structureless-massive, very friable,
II
few roots, common 7:5YR M parent material mottles
A p
0-7 lOYR 4/3 loam, weak medium granular structure, very
friable, many roots
II
Bt
7-31 7.8YR 8/8 sandy clay loam, weak medium subangular
blocky structure, friable, common roots
II
C 31-60 TM 6/6 sandy loam, structureless-massive, very friable, II
few roots, few 7.8YR 7/6 parent material mottles
Ap 0-6 lOYR 4/3 loam, weak medium granular structure. very II
friable, many roots
Bt 6-24 T.3YR 5/6 sandy clay loam, weak medium subangular II
blocky structure, friable, common roots
C 24-60 T.SYR 6/6 sandy loam, strvctureless-massive, very friable, II
few roots, common 7.8YR 7/6 parent material mottles
Ap 0-5 lOYR 4/3 loam, weak medium granular structure, very II
friable, many roots
Bt 8-22 7.5YR 8/6 sandy clay loam, weak medium subangular II
blocky structure, friable, common roots
C 22-60 7.5YR 6/6 sandy loam, strvctureless-massive, very friable, II
few roots, common 7.8YR 7/6 parent material mottles
Ap 0-7 1 OYR 4/3 loam, weak medium granular structure, very II
friable, many roots
Bt 7-28 7.M 8/6 light sandy clay loam, weak coarse subangular ll
blocky structure, friable, common roots
C 28-60 TM 8/6 sandy loam, struct relesa-massive, very friable. II
few roots
Heltzel Soil Consulting
Abbreviated Design -Conventional
Site 122-2 Albemarle County
Page q of G
A.
a. Estimated percolation rate. minutes per inch
40
b. Recommended trench bottom. inches
30
c. Depth to impervious strata/ or water table/ or limit of evaluation.
inches
68
68
68
d. Minimum separation distance required. inches
18
18
24
e. Separation distances in inches provided in design.
36
38
38
f. Sloe (percentage)
16
g. Minimum trench bottom due to slope. inches
22
h. Is the sloe greater than orequal to 10%?
Yes
i. If Ai is Yes, does 24 inches or greater to rocklimpervious strata exist below
Ab?
Yes
j. If yes to Aj, add 1 ft to the minimum center -to -center spacing beginning at 20%
slope and continue for each 10% slope increase above 20%. If no to Aj, add 1 ft to the
minimum center -to -center spacing beginning at 10% slope and continue for each 10%
slope increase above 10%. (Report the value, In Beet, of the increase in center -to -center
spacing above the minimum).
0
B.
Trench bottomsquare feet required per bedroom Table 5.4
314
C.
a. Number of bedrooms.
5
b. Gallons per day in design
760
D.
a. Length of trench. feet
100
b. Length of available area. feet
100
E.
Width of trench. feet
3
F.
Number of trenches.
6
G
Center -to -center spacing. feet
g
H.
a. Width required. feet
48
b. Width of available area. feet
103
1.
Trench bottomsquare footage required
1570
,;.
Trench bottomsquare footage in design.
1800
K. I
Is a reserve area -required? Yes
>t INo
a. Percent required?
100%
b. Percent available:
100%
Notes_ Reserve design is same as Primary
Heltzel Soil Consulti
%12 SaamevRe Road, Mamertown, VA 22844
LLC
SITE 122-2 SKETCH
TM # 69-19E & 69-19C
ALBEMARLE COUNTY, VA
`WELL #22
#zs
T.M.69-19E
REVISED LOT 4
4.62 ACRES
.j
1 B2- �o
I• Off,
B3+
B4 w 1
October 20, 2022
DRAWN BY: CSH
Pagel of b
a
"Pl
PP
\ �P5
o• eo• Lao, 1ao-
Heltzel Soil Consulting, LLC
1412 Sawmville Road, Maurertown, VA 22544
® BORE#
O PIT#
—� SLOPE DIRECTION
QPROPOSED WELL
DRAINFIELD LOCATION & SANITARY SURVEY
TM # 69-19E
ALBEMARLE COUNTY, VA
I.l V / \VI ♦`V
7 SITE 17-2 LJ
Ioo.w
EIC
W AREA WELL
U
w
,j >7 so,
i' ra gel
WELL #10
nm
WELL
#22
Page � of b
T.M.69-19E
REVISED LOT 4
/
4.62 ACRES 10
L
17'
ioo.w
October 20, 2022
DRAWN BY: CS14 o' so, too, 240•
OT LAYOUT
), ALBEMARLE CO, VA
750 (30'PRESCRIPTIVE EASEMENT)
OLD TURNPIKE ROAD
NOT TO SCALE
MOVDH
NUMENT
...................................:::::. ..
APPROXIMATE FOUND
LOCATION STREAM
toc, SRO
RHEAD
UNE \Wulf PU \'..... Q2eglHo�y?t/RNpp
♦E Iona \ \ Sag R4 c MONU H
YEuau an AaEs \ FOUND
W S1 ' ..... C
OVERHEAD \ .. OLE
UTILITY \
7 UNES VDH
y� MONUMENT
FOUND
XT
10?g ELLW 4.
22S ACRE$ n/
SWELL YIb ��N
OLE myp
VDH
�� POLE ONUMENT
FOUND
�Y/FLLYSO
IELLni VDH
3A7i "�. MONUMENT
FOUND
KRFS 11T.
CORNER IN
FENCE POST
VDH
MONUMENT
VDH FOUND
MONUMENT
FOUND
VDH
40NUMENT
FOUND
August 21, 2022
DRAWN BY: SNV
.."ANY CUTTING OR FILLING MAY RENDER THE DISPOSAL AREA
UNSUITABLE AND VOID THIS PERMIT *
Drainfield Installer: If you have any question or require minor
adjustments to this design, contact AOSE at numbers at top of this page.
Contact Heltzel Soil Consulting to schedule Pre -Construction meeting
(72-hour notice required)
VIRGINIA V/DHOF HEALTH DEPARTMENT
Protecting You and Your Environment
Sewa(-,e Disoosal Certification Letter Annroval
December 7, 2022
Page I of 3
Albemarle County Health Department
1138 Rose Hill Drive
Charlottesville, VA 22903
(434) 972-6219 Voice
(434) 972-4310 Fax
Stockton Creek, LLC APpRO
C/O Alan Taylor D
455 Second Street SE, #201 VE
Charlottesville, VA 22902
RE: Tax Map: 69-19E (Site 15-1))
HDID: 101-22-0402
Important Note: Certification Letter Approval for Site DF 15-1
Dear Alan Taylor,
This Certification Letter is issued in lieu of a sewage disposal system construction
permit in accordance with §32.1-163, et seq., of the Code of Virginia. The Board of Health
hereby recognizes that the soil and site conditions acknowledged by this correspondence, and
documented by additional records on file at the local health department, are suitable for the
installation of an onsite sewage disposal system. The attached plat shows the approved area for
the sewage disposal system. This letter is valid until a permit for construction is issued and the
system is installed, inspected and approved. This letter is void if there is any substantial physical
change in the soil or site conditions where the sewage disposal system is to be located.
The application for a certification letter was submitted pursuant to § 32.1-163.5 of the
Code of Virginia which requires the Health Department to accept private soil evaluations and
designs from an Onsite Soil Evaluator (OSE) or a Professional Engineer working in consultation
with an OSE for residential development. The site for an individual onsite sewage system was
certified as being in compliance with the Board of Health's regulations by: Chris Heltzel,
AOSE License 1940001460. This letter is issued in reliance upon that certification.
A permit to construct the sewage disposal system must be issued before construction of
the system. If the property owner (current or future) applies for a construction permit within 18
months of the date of this letter, the application fee paid for this letter shall be applied to any
state fees for a permit to construct a sewage disposal system. After 18 months, the applicant is
responsible for paying all state fees for a permit application.
Tax Map: 69-19E (Site 15-1)
HDID:101-22-0402
Page 2 of'2
This letter, and accompanying plat of survey showing the specific location of the sewage
disposal system area and well area (if applicable), may be recorded in the land records by the
clerk of the circuit court in the jurisdiction where all or part of the site or proposed site of the
system is to be located. The site shown on the plat is specific and must not be disturbed or
encroached upon by any construction. To do so voids this letter. Upon the sale or transfer of the
land that is the subject of this letter, the letter shall be transferred with the title to the property.
Future owners are advised to review the plat for the location of the onsite sewage disposal area to
make sure their building plans do not interfere with the area. If they have any questions
regarding the location of the area, they should contact the local health department for assistance.
The area evaluated, and certified by this letter, is suitable to accommodate a 5 bedroom
house using a system design of 750 gallons per day. The property will be served by a Private
water supply as shown on the attached plat. Owners are further advised that when connection to
a public water system is proposed and the public water system has reached its permitted capacity,
a permit for construction may not be issued until such time that a connection is approved and
available for use.
This letter is an assurance that a sewage disposal system construction permit will be
issued (provided there have been no substantial physical changes in the soil or site conditions
where the system would be located); however, it is not a guarantee that a permit for a specific
type of system will be issued. The design of the sewage system will be determined at the time of
application for a building permit and sewage system construction permit. The design will be
based on the site and soil conditions certified by this letter, structure size and location, water well
location (final determination to be made at time of permit issuance), the regulations in effect at
the time, and any off -site impacts that may have occurred since the date of the issuance of this
letter. In some cases, engineered plans may be required prior to issuance of the construction
permit. In accordance with § 32.1-164.1:1 of the Code of Virginia, owners are advised to apply
for a sewage disposal construction permit only when ready to begin construction.
This certification letter approval has been issued in accordance with applicable
regulations based on the information and materials provided at the time of application. There
may be other local, state, or federal laws or regulations that apply to the proposed construction of
this onsite sewage system. The owner is responsible at all times for complying with all
applicable local, state, and federal laws and regulations. If you have any questions, please contact
me.
Issued by:
JoOF Kirtley
Environmental Health Technical Consultant
COMMONWEALTH OF VIRGINIA
Application for. Q Sewage System ❑ Water Supply
Owner. Stockton Creek LLC c/o Alan Taylor
Mailing Address: 455 Second Skeet SE, B 201
Charlottesville, VA 22902
Agent: Stockton Creek LLC cfo Alan Taylor
Mailing Address: 455 2nd Street SE, Suite 201 Charlottesville, VA 22902
Site Address: TBD
Afton, VA 22020
Directions to Property.
Subdivision: DF 15.1
Tax Map: 69-19E
VDN USE ONLY
Health Dept lDa 2t14G
Due Date•
Phone: 5124284728
Fax:
Phone:
Phone: 434461-3M
Fax
Email: NmpsonGstlesconstructionmsnpsmeacom
Section: Block: Lot:
Other Property Info: Acreage: 4.82
Sewage System
Type of Approval: Applicants for new construction are advised to apply for a certification letter to determine if the land Is suitable for a sewage
system and to apply for a construction permit (valid for 18 months) only when ready to build.
D Certification Letter ❑ Construction Permit ❑ Subdivison Approval ❑ Repair
Proposed Use:
Single Family Home (Number of Bedrooms) 5 Multifamily Home (Total i of Bedrooms)
Other (Describe):
Basement 121 Yes Walk -Out Basement? Yes Fixtures In Basement? ID Yes
❑ No ❑ No ❑ No
Conditional Permit Desired? ❑ Yes ED No N yes, what type of conditions are desired?
❑ Reduced Water Flow ❑ Limited Occupancy ❑ Intermittent or seasonal use ❑ Temporary Use (1 yr. ma)imum)
Do you wish to apply for a betterment ban eligibility letter? ❑ Yes" 0 No
Water Supply
Will the water supply be ❑ Public or Private Is the water supply ❑ Exlsdng or (] Proposed
If proposed, is this a replacement well? ❑ Yes El No If yes, will the old well be abandoned? ❑ Yes ❑ No
Will any buildings within W of the well be termite treated? ❑ Yes ED No
All Applicants
Is this a private sector OSEIPE application? ID Yes ❑ No If yes, is the OSE package attached? [] Yes
❑ No
Is the Property [Mended to serve as your (the owners) principal place of residence? ❑ Yes ❑ No
In order for VDH of process your application for a sewage system, you must attach a plat or the property and a site sketch. For water eram5ea. a
yna. ve ure p,upm ry is ra mrnencae anti a SQe aRe= m nKwrea. the Site Sketch Should show your property lines, actual and/or proposed
buildings, and the desired location of your well and/or sewage system. When the site evaluation Is conducted, the property Ines, bulding location
and the proposed well and sewage sites must be dearly marked and the property sufficiently visible to see the to9ograohy.
I give ~ e+ Department of Health to ender onto the property described during normal business hours for the purpose of
rm quality assurance checks of evaluations and designs certified by a private sector Onsfte Soil Evaluator
or Engineer as until the sewage posal system and/or private water supply has been constructed and approved.
S.
<- ..o
L
o �r
kt�rrVFrh�S��� war.rrr+rr�u.��rwru..+ror/mwwtr.�.�.a RwamIL47N�
Des 87aers8; IAers Daho
FesS HDIDi€ PhWA1slnut!
•r sumo ev..rr•
Date
❑ Construction Permit ❑ Repair
Permit
OSEIPE Report For:
❑ Voluntary Upgrade Certification
Permit Letter
Page , of e
❑ Subdivision Approval
Property Location:
911 Address: THD City, State, Zip: Afton, VA 22920
Lot: Section: Subdivision: DP 15-1
GPiN or Tax Map #: 69-19E Health Dept ID #
Latitude: Longitude:
Owner :
Name: Stockton Creak LLC c/o Alan Taylor
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Prepared by:
OSE Name: Chrfs Heltral License if 1940-001460
Address: PO Box 554, Woodstock VA 220M
PE Name: License #
Address:
Date of Report 10V20y2022 Date of Revision #1: _
Date of Revision #2:
CorkentsAndex of this report:
1. Cover Sheet 5. Site Sketch
2. Soil Evaluation 6. DralnNeld Location 6 Senitary Survey
3. Profiles
4. Abbreviated Design
Certification Statement
I hereby certify that the evaluations and/or designs contain herein were conducted in accordance with the applicable provision of the
Sewage Handling 6 Disposal Regulations (f2VAC5.510), the Private Well Regulations (12 VAC54"), the Regulations for Alternative Onsite
Systems (12VAC,"13) and all other applicable laws, regulations, and policies Implemented by the Virginia Department of Heatth. I further
certify !fast I currently posses any professional license required by the laws and regulations of the Commonwealth that have been duty Issued
by the applicable agency charged with licensure to perform the work contained herein. The potential for both comrentlonal and alternative
onsite sewage systems has been discussed with the owner/applicant
❑ The wo%. " er page has been conducted under an exemption to the practice of engineering, specifically the
exempAn•ut Ebrtlga deat I a Section 64.1-402.A.11
I recommend thaw �❑ Construction P ❑ Subdivision Approval be: Issued
0 Cr�bn LsttEsr ❑ Repair Permit O Voluntary Upgrade El Denied
�46
o. xa
Z.
OSEIPE Sktnatuts: "r f LA = I n�ro 1 o i to `'
Page Z of
SOIL SUMMARY REPORT
GENERAL INFORMATION
Date: 9/9/2021 Submitted to: Albemarle County Health Department
Owner. Stockton Creek LLC efo Alan Taylor Telephone Number. 512-426 4728
Address: 455 Second Street SE, # 201 Charlottesville, VA 22902
Agent: stoddon creak LLC do Alan Taylor Address: 455 2nd street SE, suim 201 Chartotteav9b, VA 22902
Property Location: TBD Tax Map/GPIN: 69-19E
Subdivision: Blk/Sec: Site: 15-1
1. Position in Landscape Satisfactory: O Yes ❑ No
Describe: Convex Upland Sideslope
2. Slope: 6-7 %
3. Depth to Rock or Impervious Strata: Max. 764 Min. None 21
4. Depth to seasonal water table (gray mottling or gray color): Not Observed I] Yes ❑
5. Free Water Present? 21 No ❑ Yes Range: inches
6. Soil Percolation rate estimated: 0 Yes TextureGroup: 1 ❑ II ❑ 111 O IV ❑
❑ No Estimated rate: 60 mpi @ 30"
7. Permeability Test Performed? p No ❑ Yes
If yes, note type of test performed and attached results. Test Type: NA
I] Site Approved. Drainfield to be placed at 30 " depth at site designated on permit.
❑ Site Disapproved. See reasons for rejection.
Reasons for rejection:
1 ❑ Position in Landscape subject to flooding or periodic saturation.
2 ❑ Insufficient depth of suitable soil over hard rock.
3 ❑ Insufficient depth of suitable soil to seasonal water table.
4 ❑ Rates of absorption too slow.
5 ❑ _ Insufficient area of suitable soil for drainfield and/or reserve area.
8 C Proposed system to close to well.
7 ❑ Other (Specify Below. Add additional pages if necessary)
Additional Notes:
Address: Stockton Creek
Pi
P2
P3
P4
P5
P53oF(.
Reltael Soil Eval Data: 09/09/21
Consulting D-T i eld• 18-1
Ap
0-8 IUYR 3/2 silty clay, weak fine subangular blocky structure,
N
very friable, many roots
Btl
8-28 SYR 8/6 clay loam, strong medium subangular blocky
structure, friable, common roots
III
Bt2
2640 SYR 8/6 and 1 OYR 7/6 clay loam, moderate coarse
subangular blocky structure, friable, few roots
C
40-73 10YR 7/6 and BYR 8/6 silty clay, fractured, friable, few
roots, common IOYR 8/1 lithochronuc mottles
N
Ap
0-10 1OYR 3/2 silty clay, weak fine subangular blocky structure,
friable, many roots
IV
Bt 1
10-28 SYR 5/6 clay loam, strong medium subangular blocky
structure, friable, common roots
Bt2
28-41 SYR 8/8 and 1 OYR 7/6 clay loam, moderate coarse
subangular blocky structure, friable, few roots
C
41-76 IOYR 6/6 and 7/6 silty clay, structureissa - massive, very
friable
N
Ap
IOYR 3/2 silty clay, weak fine subangular blocky structure,
friable, many roots
IV
Btb
8-27 8YR 8/6 clay loam, moderate medium subangular blocky
structure, friable, common roots
BCt
36-76 7.SYR 8/8 and IOYR 6/6 light silty clay loam, wreak coarse
subangular blocky structure, friable, few roots
C
36-78 IOYR 6/6 and 7/8 silty clay, structureless - massive, very
friable
N
Ap
0-8 IOYR 3/2 silty clay, wreak fine subangular blocky structure,
very friable, many roots
N
Bt
8-28 SYR 8/6 clay loam, moderate medium subangular blocky
structure, friable, common roots
III
BCt
88-40 7-SYR 8/8 and 10YR 6/6 light silty clay loam, weak coarse
subangular blocky structure, friable, few roots
C
40-76 IOYR 6/6 and 7/6 silty clay, structureless - massive, very
friable
Ap
0-8 IOYR 3/2 silty clay, weak fine subangular blocky structure,
very friable, many roots
IV
Bt
8-30 7.6YR 8/8 clay loam, moderate medium subangular blocky
structure, friable, common roots
III
BCt -
30-4-1- 7.SYR 8/6 and IOYR 6/6 light aHty clay loam, weak coarse
III
subangular blocky structure, friable, few roots
C
OYR /6 and 7/6 silty clay, shuctureless - massive, very
. _41-78_ _
N
Heltzel Soil Consulting. LLC Page � of C
Abbreviated Design - TL3 Effluent with Trenches
Site 15-1 Albemarle County
A.
a. Estimated percolation rate, minutes per Inch
60
b. Recommended trench bottom. inches
30
c. Depth to impervious strata/ or water table/ or limit of evaluation.
inches
76
76
76
d. Minimum separation distance required. inches
1s
12
24
e. Separation distances in inches provided in design.
46
46
46
f. Sloe (percentage)
7
g. Minimum trench bottom due to slope. inches
9.6
h. Is the sloe greater than orequal to 10%?
No
i. If Ai is Yes, does 24 inches or greater to rocklimpervious strata exist below
Ab?
Yea
j. If yes to, Aj, add 1 ft to the minimum center4D-center spacing beginning at 20%
slope and continue for each 10% slope increase above 20%. If no to Aj, add 1 ft to
the minimum center -to -center spacing beginning at 10% slope and continue for each
10% slope increase above 10%. (Report the value, in feet, of the increase in center -to -
center spacing above the minimum).
0
13.a.Design
Type?
TL3
b.Trench bottomsquare feet required loading rate,
0.74
C.
a. Number of bedrooms.
5
b. Gallons per day in design
750
D.
a. Length of trench. feet
100
b. Len th of
available area. feet
100
E.
Width of trench.
feet
3
F.
Number of trenches.
4
c.
Center-to-centerspacing. feet
8
H.
a. Width required.
feet
so
b. Width of available area. feet
ss
I. iTrench
bottomsquare footage required.
1014
J.
Trench bottomsquare footage in design.
1200
K.
a. Is a reserve area required? Yes
X I
No
b. Percent required
100%
c. Percent available
100%
Notes: Reserve design is same as Primary
Heltzel Soil Consulting, LLC pap $5 of
1412 3awnsft Road, Maumdawn, VA 22644
rr..i�:�
SITE 15-1 SKETCH
TM # 69-19E
ALBEMARLE COUNTY, VA
1-1
me
wF- AREA WELL #23
T.M.69-19E
0
REVISED LOT
'P1
' �P5
'-
October 20, 2022
DRAWN BY: CSH
so, 4.62 ACRES
P2•
7403 �1 s
110'
28' \
o• 30, too, too*
Heltzel Soil Consulting, LLC rav(0 of b
1412 Saumavb Rood, Maureftwn, VA 226"
®Bou Prr# DRAINFIELD LOCATION & SANITARY SURVEY
p rr
-�- SLOPEDMEcnON TM # 69-19E
PROPOSMVAU ALBEMARLE COUNTY, VA
BRE T-t
WELL #10
GTM 17.2 L——1
D'S
rMB
WELL
ARF
,A) 171
100.W
me
� `WELL 022 \
Unx>3A
WELL #23
T.M.69-19E
REVISED LOT 4
�% `
so,
4.62 ACRES91
.PS
mw /11 'P3
B26 �p
Emma
October 20, 2022
DRAWN BY: CSH
sass
Q TABPK0P0SEDDRAR4F7
y,4,4�f�Vl
\
o•
Bo•
■so•
RA0.
Heltzel Soil Consulting, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
LOT 6
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
POND
T.M.69—BM
REVISED LOT 7
E.C.ACKERMAN TRUST
D.B.4733-23
D.B.4733-20 & 21 PLAT
D.B.4456-444
D.9.3530-234 PLAT
STATE ROUTE 803
(30-PRESCRIPTIVE EASEMENT)
GOODLOE LANE
T.M.69-6G
LOT 1
FRANK DONLEY &
CARLA DONLEY
D.B.338D-82,
85 & 86 PLAT
VDH
MONUMENT
FOUND
VDH MONUMENT FOUND
PROPOS!
STOCKTON CREEK
IOi l!
SAS.LA6
LOT.
xA14CPE5
Loin
E.N MIB
lvos`Isl-
DiA 2o941 S4�
VDH HPg3
Heltzel Soil Consultinq, LLC
PO Box 554, Woodstock, VA 22664
T.M.69-6L
STUART TAYLOR SMACK
D.B.5246-521
D.B.3415-704,707 PLAT
POND
(30'PRESCRIPTIVE EASEMENT)
VDH -�
MONUMENT
FOUND
VDH MONUMENT FOUND
EXISTIN
STOCKTON CREEK
Al'j-19G
V REVISED LOT 8
\1 2.63 ACRES
T.M.69-19F
+ 1 RLOT 5
4.63 4.63 ACRES
ST.RT
T.M..69
11.03+7
f
V�ELLY]I
p 6 ""
ELL3
T.M.69-19E
REVISED LOT 4
4.I ACRES tip'
S.
11 :
i�
T.h
a
REV:
2x
7.7
T.M.69-19D
REVISED LOT 3
4.56 ACRES
ne
VDH
MONUMENT
FOUND