HomeMy WebLinkAboutSDP202200067 Review Comments Final Site Plan and Comps. 2023-02-02$� of ets Syd Shoaf CSenior Planner, Planning County of Albemarle sshoaf@albemarle.org Community Development Department - Department Telephone: (434) 296-5832 ext. 3902 Memorandum To: Collins Engineering, scott@collins-engineering.com Date: February 2, 2023 Re: SDP202200067 Maplewood Development Final Site Plan TMP 046134-00-00-00400 - Review Comments The County of Albemarle Planning Division will grant or recommend approval of the plat referenced above once the following comments have been addressed: [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] Comments from Initial Site Plan (SDP202200049) Action Letter: [32.5.2.k] - Drainage. Provide a legend key for the storm drain connections on sheet 4 and indicate flow direction. First submittal: Comment addressed. Final Site Plan Review Comments: 1. [32.6.2 (a)] On Sheet 1, please add a date of last revision once the edits are completed. 2. [32.6.2 (a)] On Sheet 1, please add the Final Site Plan application number under the title. The application number is SDP202200067. Additionally on Sheet 1, please add a reference to the Initial Site Plan and its application number SDP202200049. 3. [32.6.2 (a)] On Sheet 1, please add a reference to SE202200019 in the "Building Heights' note 4. [32.7.4] Prior to Final Site Plan approval, a Water Protection Ordinance (WPO) application must be submitted, reviewed, and approved. Please see Engineering comments for further information. 5. [32.6.2 (a)] On Sheet 2, please provide the deedbook and page number information for all easements. Please also indicate if it is a public or private easement. 6. [32.7] Prior to Final Site Plan approval, an easement plat application must be submitted, reviewed, approved, and recorded for all proposed easements. [32.7.4.1] The easement plat must show all proposed stormwater and drainage easements. Prior to approval of the Final Site Plan, all stormwater and drainage easements created by the easement plat will need to be shown, labeled, and identified as public/private, state the width/size of the easement, and state the recorded instrument number of the plat that created the easements. b. [32.7.5] The easement plat must show all proposed water and sewer easements. Prior to approval of the Final Site Plan, all water and sewer easements created by the easement plat will need to be shown, labeled, and identified as public/private, state the width/size of the easement, and state the recorded instrument number of the plat that created the easements. 7. [32.6.2] Please submit a plat application that meets all requirements of the Subdivision Ordinance for a Special Lot subdivision application and an Easement Plat application. This combined plat can show the proposed ROW WWW.ALBEMARLE.ORG 401 McIntire Road, North Wing, I Charlottesville, VA 22902-4579 dedication and all new/proposed easements. The application fee associated with this combined Plat will be the "Easement Plat — with a deed" fee. The current fee for this type of application is $934.96. 8. [32.7.8 and 4.17] If any outdoor lighting is proposed, provide a lighting plan to be included with the final site plan submission that complies with all applicable regulations specified in Section 4.17 of the Zoning Ordinance. This includes: a. Provide footcandle measurements within the property and along all property lines. Use a light loss factor of 1.0 to determine footcandles on site. b. [4.17.4 (a)] Provide manufacturer cut sheets for all proposed outdoor luminaires. c. [4.17.4 (a)] All proposed outdoor luminaries exceeding 3,000 lumens must be full -cutoff fixtures. Please provide documentation from the manufacturers that all fixtures will be full cutoff. d. Please state the pole height of all outdoor luminaires. e. [4.17.4 (b)] Please add a note to which states "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half footcandle." 9. [32.6.2.(i)], [4.12.15 (a)] Surface materials. On Sheet 3, please indicate the type of surface material for all parking areas. 10. [32.7.9.6 (a)] Minimum area. An area of at least five percent of the paved parking and vehicular circulation area shall be landscaped with trees or shrubs. Neither the areas of street trees and shrubs required by sections 32.7.9.5(d) and (e) nor shrubs planted between a parking area and a building on the site shall be counted toward the minimum area landscaped area for a parking area. On Sheet 11, please indicate which trees are fulfilling this requirement. 11. [32.7.6 (b)] Types of plant materials. The plant materials may be a mixture of shade trees and shrubs and shall include one large or medium shade tree per ten parking spaces or portion thereof, if five spaces or more. Please provide a calculation for how many parking lot trees are needed based on the number of parking spaces proposed. 12. [ZMA202100006] On Sheet 3, please indicate which units are the affordable dwelling units. 13. [ZMA202100006] On Sheet 3, the right of way dedication for pedestrian pathway needs to be revised from 0.062 acres to 0.16 acres. Additionally, there is another right of way dedication area that is 0.01 acres near the intersection of Drexel Lane and Worth Crossing. 14. [ZMA202100006] On Sheet 3, please illustrate the proposed pedestrian crossing at the intersection of Regent Street and Worth Crossing. 15. [ZMA202100006], [32.6.2 (1)] On Sheet 3, all the proposed open space locations do not match the total open space shown in the application plan. Please revise the site plan to meet this requirement. On Sheet 1, please add a note that provides the total amount of open space provided. WWW.ALBEMARLE.ORG 401 McIntire Road, North Wing, I Charlottesville, VA 22902-4579 a. On Sheet 3, the proposed grass recreational area that is 3,390 SF must be a minimum of 0.20 acres per the ZMA202100006 Action Plan. b. On Sheet 3, please illustrate the third common space open area at the northwest section of the site. This area is 0.25 acres per the ZMA202100006 Action Plan. 16. [ZMA202100006] On Sheet 3, please add "pedestrian/bicycle trailway" next to the 10' call out. 17. [ZMA202100006] On Sheet 3 parallel to Worth Crossing, please revise the 6' landscaping buffer area to meet the 12' minimum landscape area between the road and pedestrian pathway. 18. [32.5.2 (a)], [4.19] Please indicate the garage setback from the right-of-way for Proposed Multi -Family Building #2, #3, #4, #5, and #6. Please contact Syd Shoaf in the Planning Division by using sshoaf@albemarle.org or 434-296-5832 ext.3902 for further information. Comments from Other Reviewers: Albemarle County Engineering Division - John Anderson, 4anderson2@albemarle.org - Requested changes. Please see the attached document. Albemarle County Fire Rescue - Howard Lagomarsino, hlagomarsino(a)albemarle.org - Requested changes. Please see below. 1. Caspian Lane dead ends at Building #1 and the dead end at Kerner Lane ends at building # 6 and Worth Crossing. The dead ends are greater than 150 feet, so require an acceptable turn around, which the proposed turn arounds shown do not meet the requirements for emergency vehicles. Please clarify if the interparcel travelway and at Worth's Crossing, as well as if the bollards shown are removable. 2. To utilize the hydrant on the dead end side of Caspian Lane with the FDC on Building #1 and the hydrant on Kerner Lane at Buildings # 4 and 5 in conjunction with FDC on Building # 6, requires blocking the travelway with hose, creating an impediment for fire apparatus to reach all points of the ground level of building #1 and building # 6, within 150 feet from the fire apparatus stopped on the fire apparatus access road. 3. The locations of the hydrants near the buildings must meet the water service authority requirements for clearance from the building, as determined by the water service authority. Albemarle County Architectural Review Board (ARB) - Margaret Maliszewski, mmaliszewski(a)albemarle.org - Requested changes. Please see below. An ARB application for a Final Site Development Plan is required. Provide all Final Site Plan checklist items, and address all items listed in the August 16, 2022 ARB action letter. Albemarle County Planning (Transportation) - Jessica Hersh-Ballering, ihballering@albemarle.org - Requested changes. Please see below. 1. Site plan should more clearly indicate that shared use path is to be constructed along Proffit Road (rather than solely dedicating right-of-way), particularly on page 3. 2. CG-12 ADA ramp on the northeast corner of the property is not labeled 3. There appear to be significant gaps in the plan's pedestrian infrastructure for internal circulation. Specifically, when sidewalks intersect Drexel Lane and Keener Lane, the sidewalks end abruptly with the sidewalk offset by at least WWW.ALBEMARLE.ORG 401 McIntire Road, North Wing, I Charlottesville, VA 22902-4579 50' on the opposite side of the street (Drexel) or not continuing at all (Keener). In accordance with Albemarle County Code Sec. 32.7.2.3.b, the applicant should revise the sidewalk plan so that individuals using the sidewalks - and especially those reliant on the CG-12 ADA ramps - are not forced to walk in the roadway. The proposed layout is a safety concern. Virginia Department of Transportation - Max Greene, max.greene@vdot.virginia.gov - Requested changes. Please see the attached document. Albemarle Cunty E911 Service - Andrew Slack, aslack@albemarle.org - No objection. Rivanna Water & Sewer Authority - Dyon Vega, dvega@rivanna.org - No objection. Albemarle County Inspections - Betty Slough, bslough@albemarle.org - Pending. Comments will be forwarded to the applicant upon receipt. Albemarle County Service Authority - Richard Nelson, rnelson0serviceauthoritv.org - Pending. Comments will be forwarded to the applicant upon receipt. WWW.ALBEMARLE.ORG 401 McIntire Road, North Wing, I Charlottesville, VA 22902-4579 a$ County of Albemarle m COMMUNITY DEVELOPMENT DEPARTMENT Site Plan Review Project title: Maplewood Development— Final Site Plan Project file number: SDP202200067 Plan preparer: Scott Collins, PE, Collins Engineering 200 Garrett Street, Suite K, Charlottesville, VA 22902 scott(&,,collins-ent ineering.com Owner or rep.: Maplewood Investments LLC 455 Second Street SE, Suite 201 Charlottesville, VA 22902 alan(a),,riverbenddev. com Plan received date: 27 Dec 2022 Date of comments: 30 Dec 2022 Review coordinator: Syd Shoaf Reviewer: John Anderson, PE 401 McIntire Road, North Wing Charlottesville, VA 22902-4579 Telephone: 434-296-5832 WWW.ALBEMARLE.ORG Engineering has completed review of the Final Site Plan, and offers the following review comments: 1. General (for ESP approval): a. Approved WPO required. b. WPO plan approval requires: i. Recorded SWM facility /public drainage easement, with deeds. ii. Recorded SWM facility Maintenance Agreement. iii. Recorded temp grading /access easement w/ TMP 46114-3. 2. Sheet 2: General Note 4., please clarify `the site is currently under construction,' since it does not appear to be. 3. Sheet 5: Provide copy of recorded variable width temporary grading and access easement on adjacent parcel, TMP 46134-3 (Forest Lakes Self -Storage); this item is required for Final Site Plan Approval. 4. Sheet 8: Increase pipe DIA pipe UGDI to Str. 38 to 24", since proposed 18" DIA capacity =8.28cfs while Qt=8.27cfs. 5. Sheet 9: A number of pipes are proposed 0.50% (Minimum). Flexible HDPE at 0.5% risks error that may be difficult or expensive to remedy if deflection or deformation relating to flat grade exceed max. tolerance. Encourage increase 0.50% slightly, if only to 0.55%, to offset risk during construction, to allow slight error. 6. Sheet 9: Revise lower -right text block reference to 2008 R&B Standards to ref. 2016 R&B Std., instead. 7. Sheet 10: For Caspian Lane, provide VDOT underdrain at cut /fill transition, Sta. 13+10 approx. 8. Increase Str. 16 DI throat length to 10', inlet is located on Drexel Lane, a principal access and final site plan inlet design table (VDOT LD-204), sheet 8A, SDP202200067 indicates Lt, this inlet=10.68' but inlet throat length provided is only 6' causing inlet carryover during 6.5" /hr. storm intensity event. 9. Sheet 3 a. Revise label /relocate leader line at SE comer of building #2 to `Proposed 5' conc. SW' that points to sidewalk. Engineering Review Comments Page 2 of 4 --------------i- --- f SET-9A6K - - - ______ i____i 12`, IM r PROPOSED (r) vuU t b t U. t TCONC. SIW RI-1 STOP SfW b. Entrance. Drexel Lane : driveway entrances. Caspian Lane : stop sign. Int. Drexel - Caspian. Entrance from Worth Crossing, drives, and stop sign at building 4, discussed below. It may be possible to preserve units and meet standards, but there is point at which maximum density meets design /safety standards, beyond which, spatial constraints limit number of units. Proposed buildings, internal network, recreational areas, additional parking, secondary emergency access, SWM, and aesthetic features reflect design that nearly meets (VDOT) standards. A stop sign at Drexel -Caspian must be visible (item 9.b.iv., below). At Applicant's discretion, two stop signs on Caspian may replace single stop on Drexel, revised thru-motion likely meets drivers' expectations. i. Provide >_ 35' throat length between curb at Worth Crossing and drive entrances nearest Worth Crossing (bldg. #2 and #3). See VDOT Road Design Manual, Apppx F, Sec. 4 Entrance Design, p. 104 for definition, Commercial Entrance (Drexel Lane -Worth Crossing is a commercial entrance), design subject to p. 109, Table 4-2, Summary of Entrance Throats, and Fig. 44A Entrance Throat Detail. Increase distance from curb to radius return, first driveway/s to > 35'. Number of Egress Lanes (left, thru and right) Minimum Throat Length Feet 1 35 2 75 3 200 4 300 TABLE 4-2 SUMMARY OF ENTRANCE THROATS Source: Transportation & Land Development 20d Edition 2003, Koepke and Stover Inadequate entrance length can also produce hazards to entering traffic on site. Particularly where the on -site parking can back out of and block the entrance and prevent a vehicle from entering. To avoid this problem, a distance of at least 50 feet is used on entrance length where back out parking may interfere with entry movement. Inwrrect Correct ------------- -------- FIGURE 4-1A ENTRANCE THROAT DETAIL Please compare with sheet 3 Entrance design --------------------- u--. (MINJ wJ_ I81ON Engineering Review Comments Page 3 of 4 � I RE __ ______F_____ ____ EZ � __' PARKING: BEGIN : . L}_�_______________9_ --_� /III' 'IPI911EEE9v1 ------------ - 1 RAAP I�TARI IPIVDOT ii. Revise drive entrances (all entrance) to show radii at each driveway. iii. Revise driveways of south -most units, building #4, so accessible, similar to blue -circle /check mark west -most units, building #2, which are accessible. The two south -most unit drives at bldg. #4 do not work. Design must ensure each unit has accessible, safe drive entrance without vehicles crossing travelway centerline, whether CL is marked or not. .._...._.. .. ,..--------------.....,.FPW .-1. CG2CUR6 PARKING ---'-- - _ SIGN 495'R CASPIAN LANE (28'PRIVATE ACCESS RMLSACE---- = IG VDOT - _ EASEMENT) PROPOSEDCU (P)G STD. CGe BCONIC. Sm IP)VlKIT am. wn RLf SGN 9'TYP IIII E 9•� I �jS ,LSP (P19lNE 51GH /Y\ I NO lVP P IG 9 r1 - I 1 .i__ 50.0' IPI T CGI .Ip R4 P u'00 (MIN.I GARAGE - I (P) VDOi STD. IPINO PARKING OG-12 ADA RAMP SIGN PROPOSED 5'CONC. SM • • ' S' f:DNC: 9NA \ 8 ACCESS ESMT - PROPOSED 22 E/P.E/P �E - 500' MULTI -FAMILY _ - PL, BUILDING#2 '- IPI NO 13 UNITS PARKING 9.710 SF �/ SIGN PROPOSED WEE MULTI-FAMIL' YCGA NGPO� _____ '-_ (P)Rp1-FACE '. CIIRRNI, __ - BUIL�ING #` - iv. South edge of building #4, < 1.0' to BC, Drexel Lane, obscures stop sign. Revise to ensure stop sign at Caspian -Drexel is visible and does not overhang the travel way. (P) STRE& SIGN 1--- (P) 00 STD. Thank you. Engineering Review Comments Page 4 of 4 (P) VDOT STD. / R1-1 STOP SIGN :' I I 1 iL ALV'-1 I rn (MIN.) 1 4. 0D GGARAGE --- r------I I I 1 I Please call if any questions — tel. 434.296-5832-x3069, or email 4anderson2(a)albemarle.org. SDP202200067_Maplewood Dev_FSP_123022.docx (Z) COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION Stephen C. Brich, P.E. 1401 East Broad Street Commissioner Richmond, Virginia 23219 January 19, 2022 Syd Shoaf County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Re: SDP-2022-00067 — Maplewood Development - FSP Dear Mr. Shoaf: (804) 786-2701 Fax: (804) 786,2940 The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced Maplewood Development, as submitted by Collins Engineering, dated October 28, 2022 and find the following: 1. Please submit turn lane warrants with proposed volume counts for review, per section 3 of RDM appendix F. 2. Mill/overlay areas will need to be extended to a minimum F past the proposed work along the existing State routes. 3. Proposed roundabout for the intersection of Rte. 649 and Rte. 1722 is not on any schedule with VDOT. Will roundabout be constructed in conjunction with this project? Otherwise, curb and gutter should be installed per County Code to complete this project. 4. Forest Lakes Self Storage project has not been approved and entrance location as shown has not been established. Construction of off -site hardscapes will be at the risk of the developer. 5. CG-12 across right in lane from Rte. 649 is a mid -block crossing and will need a warrant submitted for review. 6. Existing drainage along Rte. 649 into 15" RCP across right turn lane will need to be adequately addressed. VirginiaDOT.org WE KEEP VIRGINIA MOVING 7. Due to the level of items noted in this review, these comments may not be exhaustive. A VDOT Land Use Permit will be required prior to any work within the right of way. The owner/developer must contact the Charlottesville Residency land Use Section at (434) 422-9399 for information pertaining to this process. If you have further questions please contact Max Greene at (434) 422-9894. Sincerely, John C. Wilson, P.E. Assistant Resident Engineer Area Land Use Charlottesville Residency