Loading...
HomeMy WebLinkAboutSDP201300005 Review Comments 2013-01-22 (3) Ellie Ray From: Michelle Roberge Sent: Tuesday, May 07, 2013 10:23 AM To: Ellie Ray Subject: Planning Application Review for SDP201300005 Hollymead Substation-Minor. The Review for the following application has been completed: Application Number=SDP201300005 Reviewer= Michelle Roberge Review Status = No Objection Completed Date =05/07/2013 1 ',.r �.�pFAAL�k !till lll�1111197' !Ole' IRGINZP COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road,North Wing Charlottesville,Virginia 22902-4596 Phone(434) 296-5832 Fax(434) 972-4126 February 14, 2013 Charlene Harper, P.E., LEED AP Geosyntec Consultants 2727 Enterprise Parkway, Suite 103 Richmond,VA 23294 RE: SDP201300005 Hollymead Substation—Minor Amendment Dear Charlene: Your minor amendment has been reviewed. In order for the minor amendment to be approved the following revisions are required: 1. [32.5.2(a)] Provide the name of the owner on the Cover Sheet. Please also add R-15 to the Zoning note, a portion of this parcel is zoned R-1 and a portion is zoned R-15. 2. [32.5.2(a)] Please verify the accuracy of the boundary lines. The lines shown (within proximity of the proposed work)appear much closer than those shown in GIS. 3. [32.5.2(a)] Provide the source of survey and topography. 4. [32.5.2(d)] Show areas of the site where existing slopes are critical slopes. 5. [4.2.6(c)] The Agent has determined that this use is exempt from the building site requirements of section 4.2.2. The applicable exemption section reads as follows, "A lot, structure, or improvement may be exempt from the requirements of section 4.2 as provided herein: ...(c)Accessways, public utility lines and appurtenances, storm water management facilities, and any other public facilities necessary to allow the use of the parcel shall not be required to be located within a building site and shall not be subject to the requirements of this section 4.2.2, provided that the applicant demonstrates that no reasonable alternative location or alignment exists. The county engineer shall require that protective and restorative measures be installed and maintained as deemed necessary to insure that the development will be consistent with the intent of section 4.2 of this chapter." Engineering comment#1 may be disregarded, but the reviewing engineer can require additional protective or restorative measures as noted above. 6. [32.6.1(a)] Site Plans, and any amendments to a plan, must be prepared, sealed, signed and dated by an architect, professional engineer, land surveyor, or certified landscape architect, each of whom shall be licensed to practice in the Commonwealth of Virginia. Please seal, sign and date each page of the plan set. 7. [32.6.2(j)] The landscape plan sheet should show any proposed tree removal. 8. [32.6.2(j) &32.7.9.4(b)] Existing trees may be preserved in lieu of planting new plant materials in order to satisfy the landscaping and screening requirements of section 32.7.9. The landscape plan should show the trees to be preserved, the limits of clearing,the location and type of protective fencing, ,rrde changes requiring tree wells or walls, aritTerenching or tunneling proposed beyond the limits of clearing. The applicant shall sign a conservation checklist approved by the agent to ensure that the specified trees will be protected during construction. Except as otherwise expressly approved by the agent in a particular case, the checklist shall conform to the specifications in the Virginia Erosion and Sediment Control Handbook, pages III- 393 through III-413, and as hereafter amended. This checklist should be scanned and added to the Landscape Plan Sheet. 9. [32.6.2(j) &32.7.9.7] Screening that meets the requirements of 32.7.9.7(d) is required (minimum 20' depth). It appears that existing vegetation meets this requirement; please verify. If this is correct,the addition of the above-noted conservation plan and checklist will satisfy this comment. 10. [32.6.2(j) &32.7.9.8] Tree canopy that meets the requirements of 32.7.9.8(a)(1) is required (minimum 10% of parcel). It appears that existing vegetation meets this requirement; please verify. If this is correct,the addition of the above-noted conservation plan and checklist will satisfy this comment. 11. [32.6.2(k) &4.17] Please clarify if any new outdoor lighting is proposed. If new fixtures are proposed, a lighting plan must be submitted that meets the requirements of section 4.17. 12. [Comment] This site plan amendment cannot be approved until VDOT completes their review and grants their approval; comments will be forwarded upon receipt. Zoning, Fire/Rescue, inspections, and ACSA have completed their reviews and each has no objection. Engineering comments have been provided. Staff has provided references to provisions of Chapter 18 of the Code of the County of Albemarle. The Code is kept up to date by the County Attorney's office. The Code may found on the County Attorney's website which may be found under"Departments and Services"at Albemarle.org. In accord with the provisions of Section 32.4.3.5 of Chapter 18 of the Code if the developer fails to submit a revised final site plan to address all of the requirements within six (6) months after the date of this letter the application shall be deemed to have been voluntarily withdrawn by the developer. If you have any questions about the comments please feel free to contact me. Sincerely, &th_ 6. 26uo Ellie Carter Ray, CLA Senior Planner Planning Division At,y45. COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road,Room 227 Charlottesville,Virginia 22902-4596 Phone(434)296-5832 Fax(434)972-4126 Project: Hollymead Substation Expansion-Minor Amendment to SDP-1984-60 Plan preparer: Geosyntec Consultants [fax 804-767-2182] Owner or rep.: Virginia Electric&Power CO Plan received date: 22 Jan 2013 Date of comments: 11 Feb 2013 Reviewer: Michelle Roberge A. Site Development Plan(SDP201300005) 1. It appears there is one critical slope located south of site that will be be slightly disturbed during the construction of the additional gravel area. It also appears that the runoff for the entire site will be routed into a stormsewer with the outflow concentrated near the critical slope area. The applicant requesting the waiver shall file a written request explaining how the waiver, if granted, would address the rapid and/or large-scale movement of soil and rock, excessive stormwater run- off, siltation of natural and man-made bodies of water, loss of aesthetic resources, and, in the event of septic system failure,a greater travel distance of septic effluent(collectively referred to as the "public health, safety, and welfare factors")that might otherwise result from the disturbance of critical slopes. [Section 4.2.5] 2. Please show the drainage easements within the property boundary. 3. The property drains into a lake managed by the Forest Lakes Community. Per Section 17.314 and section 17.315,water quality and quantity will need to be addressed. A WPO application can be filled out for the stormwater management and erosion and sediment control review. The load reduction calculation spreadsheet can be found on our website, www.albemarle.org/deptforms.asp?department=cdd. The file name is Plan Review BMP Removal Rate Computations. 4. Please show the the VDOT Flared End Section ES-I for the outlet pipe. 5. The area between the proposed grate inlets will start ponding.Please revise to prevent ponding. 6. Please provide the detail of the 1' wide wall located south of site. 7. On sheets 5 and 9 for post development,please do not show the grate inlet and pipe to be removed. 8. Please revise E2 to be a 24"RCP outlet pipe. 9. The site will eventually drain into(2)— 12"DIP before entering the pond. Please replace pipes with a 24"RCP. This will require permission from the Forest Lakes Community Association, Inc. Please provide. Sincerely, tor I, I Michelle Roberge County Engineer Review Comments Project Name: Hollymead Substation - Minor Minor Amendment Date Completed: Friday, January 25, 2013 Reviewer: Jay Schlothauer Department/Division/Agency: Inspections Reviews Comments: Review Status: No Objection Review Comments Project Name: Hollymead Substation - Minor Minor Amendment Date Completed: Monday, February 04, 2013 Reviewer: Robbie Gilmer Department/Division/Agency: Fire Rescue Reviews Comments: Based on SDP 1/22/13 No Objection or comments Review Status: No Objection Review Comments Project Name: Hollymead Substation -Minor Minor Amendment Date Completed: Thursday, February 07, 2013 Reviewer: Alexander Morrison Department/Division/Agency: ACSA Reviews Comments: Review Status: No Objection