Loading...
HomeMy WebLinkAboutWPO202200039 VSMP - SWPPP 2023-02-07�osAlrlCOUNTY OF ALBEMARLE � Department of Community Development ." ++ 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Tel. (434) 296-5832 • Fax (434) 972-4126 Stormwater Pollution Prevention Plan (SWPPP) Project Name: Address: For Construction Activities At: 3226 Proffit Road Charlottesville, Virginia 22911 Prepared by: Name: Wetland Studies and Solutions, Inc. Prepared for: Name: Greenwood Homes SWPPP Preparation Date: August 2022 (This document is to be made publicly available according to 9VAC25-880-70, Part II, section D) Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County CONTENTS: (from Albemarle County Code Sec. 17-405) 1. Registration statement 2. Notice of general permit coverage 3. Nature of activity 4. Erosion and Sediment Control Plan. 5. Stormwater Management Plan 6. Pollution Prevention Plan. 7. Discharges to impaired waters, surface waters within an applicable TMDL wasteload allocation, and exceptional waters. 8. Qualified personnel 9. Signed Certification 10. Delegation of authority. 11. General permit copy 12. Inspection logs Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Section 1. Registration statement (Provide a signed completed copy of the DEQ registration statement) Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY GENERAL VPDES PERMIT FOR DISCHARGES OF STORMWATER FROM CONSTRUCTION ACTIVITIES (VAR10) REGISTRATION STATEMENT 2019 Application type. ® NEW PERMIT ISSUANCE (CHOOSE ONE) ❑ MODIFICATION WITH ACREAGE INCREASE ❑ MODIFICATION WITHOUT ACREAGE INCREASE ❑ EXISTING PERMIT RE -ISSUANCE Section 1. Operator/Permittee Information. PERMIT #: PLAN/ID #: TECHNICAL CRITERIA: 116 ❑ HC ❑ A. Construction Activity Operator (Permittee). The person or entity that is applying for permit coverage and will have operational control over construction activities to ensure compliance with the general permit. A person with signatory authority for this operator must sign the certification in Section V. (per Part III. K. of the VAR10 Permit). Operator Name: Greenwood Homes Charlottesville, LLC. Contact person: Scott Carlson Address: 6535 Woodbourne Lane City, State and Zip Code: Crozet, Virginia 22932 Phone Number: 434-249-9626 Primary and CC Email: scoff@ reenwoodhomes.com; chollandsworth@wetiands.com B. Electronic correspondence. To receive an emailed coverage letter or to pay by credit card, you must choose YES and include a valid email. May we transmit correspondence electronically? YES ® NO ❑ Section 11. Construction Activity Information. A. Include a site map showing the location of the existing or proposed land -disturbing activities, the limits of land disturbance, construction entrances and all waterbodies receiving stormwater discharges from the site. B. Project site location information. Construction Activity Name: Proffit Road Townhomes South Address: 3226 Proffit Road City and/or County and Zip Code: Charlottesville, Virginia 22911 Construction Activity Entrance Location (description, street address and/or 38.131278,-78.431425 latitude/longitude in decimal degrees): Latitude and Longitude N/A (6-digit, decimal degrees format): C. Acreage totals for all land -disturbing activities to be included under this permit coverage. Report to the nearest one -hundredth of an acre. Total land area of development (include entire area to be disturbed as approved in the Stormwater Management Plan): 3.34 Primary estimated area to be disturbed (include portions with 2.94 Erosion and Sediment Control Plan approval only): Off -site estimated area to be disturbed (if applicable): N/A D. Property Owner Status: FEDERAL ❑ STATE ❑ PUBLIC ❑ PRIVATE 1X E. Nature of the Construction Activity Description (i.e. commercial, Residential Townhouses industrial, residential, agricultural, environmental, utility): F. Municipal Separate Storm Sewer System (MS4) name(s) (if the site is discharging to a MS4): N/A G. Estimated Project Dates (MM/DD/YYYY). Start Date: 09 01 2022 Completion Date: 09/01/2023 H. Is this construction activity part of a larger common plan of YES KI NO ❑ development or sale? Rev 11/2020 PAGE 1 1 6 CONSTRUCTION GENERAL PERMIT (VAR10) REGISTRATION STATEMENT 2019 I. 6" Order Hydrologic Unit Code (HUC) and Receiving Water Name(s). Include additional areas on a separate page. HUC NAMES) OF RECEIVING WATERBODY 020802040203 (1R08) Powell Creek to South Fork Rivanna River Section III. Off -site Support Activity Location Information. List all off -site support activities and excavated material disposal areas being utilized for this project. Include additional areas on a separate page. Off -site Activity Name: N/A Address: City or County: Off -site Activity Entrance Location (description, street address and/or latitude/longitude in decimal degrees): Latitude and Longitude (6-digit, decimal degrees format): Is this off -site activity an excavated material disposal area? YES ❑ NO ❑ If this off -site activity is an excavated material disposal area, list the contents of the excavated fill material: Will a separate VPDES permit cover this off -site activity? YES ❑ NO ❑ Section IV. Other Information. A. A stormwater pollution prevention plan (SWPPP) must be prepared in accordance with the requirements of the General VPDES Permit for Discharges of Stormwater from Construction Activities Prior t0 submitting the Registration Statement. By signing the Registration Statement, the operator is certifying that the SWPPP has been prepared. B. Has an Erosion and Sediment Control Plan been YES ® NO ❑ submitted to the VESC Authority for review? Erosion and Sediment Control Plan Approval Date (for 06/17/2021 the estimated area to be disturbed MM/DD/YYYY): C. Has land -disturbance commenced? YES IN NO ❑ D. Annual Standards and Specifications. If this project is utilizing approved Annual Standards and Specifications (AS&S), attached the completed AS&S Entity Form. AS&S Entity Name (if different from the Operator N/A identified in Section I): E. Billing information (leave blank if same as the Operator identified in Section I. above). This entity will receive Annual Permit Maintenance and Permit Modification Fee invoices (if applicable). Billing Name: Contact Name: Address: City, State and Zip Code: Phone Number: Primary and CC Email: Rev 11/2020 PAGE 2 16 CONSTRUCTION GENERAL PERMIT (VAR10) REGISTRATION STATEMENT 2019 Section V. Certification. A person representing the operator as identified in Section I. A. and meeting the requirements of 9VAC25-880-70. Part III. K must physically sign this certification. A typed signature is not acceptable. Please note thal operator is defined in 9VAC25-870-10 as follows: "Operator" means the owner or operator of any facility or activity subject to the Act and this chapter. In the context of stormwater associated with a large or small construction activity, operator means any person associated with a construction project that meets either of the following two criteria: (i) the person has direct operational control over construction plans and specifications, including the ability to make modifications to those plans and specifications or (H) the person has day-to-day operational control of those activities at a project that are necessary to ensure compliance with a stormwater pollution prevention plan for the site or other state permit or VSMP authority permit conditions (i.e., they are authorized to direct workers at a site to carry out activities required by the stormwater pollution prevention plan or comply with other permit conditions). In the context of stormwater discharges from Municipal Separate Storm Sewer Systems (MS4s), operator means the operator of the regulated MS4 system. 9VAC2 5-880- 70. Part 111. K. Signatory Requirements. Registration Statement. All Registration Statements shall be signed as follows: a. For a corporation: by a responsible corporate officer. For the purpose of this chapter, a responsible corporate officer means: (i) a president, secretary, treasurer, or vice-president of the corporation in charge of a principal business function, or any other person who performs similar policy -making or decision -making functions for the corporation; or (ii) the manager of one or more manufacturing, production, or operating facilities, provided the manager is authorized to make management decisions that govern the operation of the regulated facility including having the explicit or implicit duty of making major capital investment recommendations, and initiating and directing other comprehensive measures to assure long-term compliance with environmental laws and regulations; the manager can ensure that the necessary systems are established or actions taken to gather complete and accurate information for state permit application requirements; and where authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures; b. For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or c. For a municipality, state, federal, or other public agency: by either a principal executive officer or ranking elected official. For purposes of this chapter, a principal executive officer of a public agency includes: (i) the chief executive officer of the agency or (H) a senior executive officer having responsibility for the overall operations of a principal geographic unit of the agency. Certification: "I certify under penalty of law that I have read and understand this Registration Statement and that this document and all attachments were prepared in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is to the best of my knowledge and belief true, accurate, and complete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment for knowing violations." Printed Name: Signature (signed 1n ink): Date Signed: $'2S/ZZ: Section VI. Submittal Instructions. Submit this form to the VSMP Authority. If the locality is the VSMP Authority, please send your Registration Statement submittal directly to the locality; do NOT send this form to DEQ. A list of local VSMP Authorities is available here: VSMP Authorities. If DEQ is the VSMP Authority, please send to: If the locality is the VSMP Authority, please send to: Department of Environmental Quality Office of Stormwater Management Suite 1400 PO Box 1105 Richmond VA 23218 constructiongp@deq.virftinia.gov Rev 11/2020 PAGE 3 16 CONSTRUCTION GENERAL PERMIT (VAR10) REGISTRATION STATEMENT 2019 INSTRUCTIONS PLEASE DO NOT PRINT OR SUBMIT This Registration Statement is for coverage under the General VPDES Permit for Discharges of Stormwater from Construction Activities. This form covers the following permit actions: new permit issuance, existing permit modification with an increase in acreage, existing permit modifications that result in a plan modification but do not result in an increase in disturbed acreage, and reissuance of an active permit coverage. Application type. Select NEW PERMIT ISSUANCE to obtain a new permit coverage. Modifications are for modifying an existing, active permit coverage. Select MODIFICATION WITH ACREAGE INCREASE when the previously approved acreage(s) increases (permit modifications are not performed for decreases in acreage unless they result in plan changes —see Modification WITHOUT Acreage Increase). Select MODIFICATION WITHOUT ACREAGE INCREASE when there is a change to the site design resulting in a change to the approved plans with no increase in acreage(s). Select EXISTING PERMIT REISSUANCE to extend an expiring permit coverage for the next permit cycle and include the existing permit number. Section I. Operator/Permittee Information. A. Construction Activity Operator (Permittee). The person or entity that is applying for permit coverage and will have operational control over construction activities to ensure compliance with the general permit. For companies, use the complete, active, legal entity name as registered with a state corporation commission. Entities that are considered operators commonly consist of the property owner, developer of a project (the party with control of project plans and specifications), or general contractor (the party with day-to-day operational control of the activities at the project site that are necessary to ensure compliance with the general permit). If an individual person is listed as the operator, that person (or a legal representative of) must sign the certification in Section V. An operator may be one of the following: 9VAC25-870-10. Definitions. "Operator" means the owner or operator of any facility or activity subject to the Act and this chapter. In the context of stormwater associated with a large or small construction activity, operator means any person associated with a construction project that meets either of the following two criteria: (i) the person has direct operational control over construction plans and specifications, including the ability to make modifications to those plans and specifications or (ii) the person has day-to-day operational control of those activities at a project that are necessary to ensure compliance with a Stormwater pollution prevention plan for the site or other state permit or VSMP authority permit conditions (i.e., they are authorized to direct workers at a site to carry out activities required by the Stormwater pollution prevention plan or comply with other permit conditions). In the context of stormwater discharges from Municipal Separate Storm Sewer Systems (MS4s), operator means the operator of the regulated M54 system. "Owner" means the Commonwealth or any of its political subdivisions including, but not limited to, sanitation district commissions and authorities, and any public or private institution, corporation, association, firm or company organized or existing under the laws of this or any other state or country, or any officer or agency of the United States, or any person or group of persons acting individually or as a group that owns, operates, charters, rents, or otherwise exercises control over or is responsible for any actual or potential discharge of sewage, industrial wastes, or other wastes or pollutants to state waters, or any facility or operation that has the capability to alter the physical, chemical, or biological properties of state waters in contravention of § 62.1-44.5 of the Code of Virginia, the Act and this chapter. "Person " means any individual, corporation, partnership, association, state, municipality. commission, or political subdivision of a state, governmental body, including a federal, state, or local entity as applicable, any interstate body or any other legal entity. B. May we transmit correspondence electronically? If you choose YES to this question and provide an email address in Section I. A., all correspondence, forms, invoices and notifications will be transmitted by email to the operator. This will also give the operator the ability to pay by credit card and to receive permit coverage approval letters immediately upon permit approval. Section II. Construction Activity Information. A. A site map indicating the location of the existing or proposed land -disturbing activities, the limits of land disturbance, construction entrances and all water bodies receiving stormwater discharges from the site must be included with the submittal of this form. Aerial imagery maps or topographic maps showing the required items are acceptable. Plan sheet sized site maps are not required. Please consult your VSMP authority if you have additional questions regarding site map requirements. B. Construction Activity Name and location. Provide a descriptive project name (it is helpful to use the same naming convention as listed on the Stormwater Management plans), 911 street address (if available), city/county of the construction activity, and the 6-digit latitude and longitude in decimal degrees format for the centroid, main construction entrance or start and end points for linear projects (i.e. 37.1234N/-77.1234W). C. Acreage totals for all land -disturbing activities, on- and off -site, to be included under this permit. Acreages are to be reported to the nearest one -hundredth acre (two decimal places; i.e. 1.15 acres). Provide the total acreage of the primary development site as approved on the Stormwater Management Plans and the primary on -site estimated acreage to be disturbed by the construction activity as approved under the Erosion and Sediment Control Plans. The off -site estimated area to be disturbed is the sum of the disturbed acreages for all off -site support activities to be covered under this general permit. Do not include the off -site acreage totals in the primary, on -site total and estimated disturbed acreage totals. Permit fees are calculated based on your disturbed acreage total for all on- and off -site areas being disturbed under this permit coverage (the sum of all on -site and off -site disturbed acreages). D. Property owner status. The status of the construction activity property owner. Any property not owned by a government entity or agency (i.e. federal, state or local governments) is PRIVATE. Rev 11/2020 PAGE 4 16 CONSTRUCTION GENERAL PERMIT (VAR10) REGISTRATION STATEMENT 2019 INSTRUCTIONS PLEASE DO NOT PRINT OR SUBMIT E. Nature of the construction activity description. Choose the designation that best describes the post -construction use of this project (you may choose more than one). (Le. Residential, Commercial, Industrial, Agricultural, Environmental, Educational, Oil and Gas, Utility, Transportation, Institutional, etc.). Describe the post -construction use of the project (i.e. Commercial —one new office building and associated parking and utilities; Transportation — Linear roads, sidewalks and utilities; Agricultural —3 Poultry Houses, etc.). F. Municipal Separate Storm Sewer System (MS4) name(s) if discharging to a MS4. If stormwater is discharged through a MS4 (either partially or completely), provide the name of the M54(s) that will be receiving water from this construction activity. The M54 name is typically the town, city, county, institute or federal facility where the construction activity is located, G. Estimated project dates. Provide the estimated project start date and completion date in Month/Day/Year or MM/DD/YYYY format (i.e. 07/30/2019). H. Is this construction activity is part of a larger common plan of development or sale? "Common plan of development or sale" means a contiguous area where separate and distinct construction activities may be taking place at different times on different schedules per 9VAC25-870-10. Definitions. I.e. a subdivision, commercial development, business park, etc. I. Gth Order Hydrologic Unit Code (HUC) and associated Receiving Water Name(s). Provide all 6th order HUCs and receiving waterbody names, for the primary site and any Off -site areas included under this permit coverage, that could potentially receive stormwater runoff discharging from this activity. The HUC can be either a 12-digit number (i.e. 0208010101) or 2-letter, 2-number code (i.e. JL52). Include additional HUCs or receiving waters on a separate page. You may utilize DEQ's web -based GIS application, VEGIS, to obtain this information. • VEGIS application link: DEQ's VEGIS Mapping Application • Instructions for utilizing DEQ's VEGIS application link: CGP-GIS HUC Instructions Section III. Off -site Support Activity Location Information. This general permit also authorizes stormwater discharges from support activities (e.g., concrete or asphalt batch plants, equipment staging yards, material storage areas, excavated material disposal areas, borrow areas) located on -site or off -site provided that 0) the support activity is directly related to a construction activity that is required to have general permit coverage; (ii) the support activity is not a commercial operation, nor does it serve multiple unrelated construction activities by different operators; (iii) the support activity does not operate beyond the completion of the construction activity it supports; (iv) the support activity is identified in the Registration Statement at the time of general permit coverage; (v) appropriate control measures are identified in a SWPPP and implemented to address the discharges from the support activity areas; and (vi) all applicable state, federal, and local approvals are obtained for the support activity. Off -site activity name and location information. Provide a descriptive off -site project name, 911 street address (if available), construction entrance location (address or decimal degrees coordinates and description), city/county and the 6-digit latitude and longitude in decimal degrees (i.e. 37.1234N,77.1234W) of all off -site support activities. Indicate whether the off -site support activity will be covered under this general permit or a separate VPDES permit. If excavated material (i.e., fill) will be transported off -site for disposal, the name and physical location address, when available, of all off -site excavated material disposal areas including city or county; 6-digit latitude and longitude in decimal degrees (i.e. 37.1234N, 77.1234W) and the contents of the excavated material. List additional off -site areas to be included under this permit coverage on a separate page. Off -site areas not included on this registration will need to obtain coverage under a separate VPDES permit. Section IV. Other Information. A. A stormwater pollution prevention plan (SWPPP) must be prepared prior to submitting the Registration Statement per 9VAC25-880. See 9VAC25-880-70. Part II. of the General Permit for the SWPPP requirements. S. If the Erosion and Sediment Control Plan for the estimated area to be disturbed listed in Section H. C. has been submitted to the VESC Authority for review and plan approval, choose YES. If you are submitting this application to reissue an existing permit coverage, please provide the date that the VESC Authority approved the Erosion and Sediment Control Plan for the estimated area to be disturbed. C. If land disturbance has commenced, choose YES. "Land disturbance" or "land -disturbing activity" means a man-made change to the land surface that may result in soil erosion or has the potential to change its runoff characteristics, including construction activity such as the clearing, grading, excavating, or filling of land per §62.1-44.15:24. Definitions. D. If this project is using approved Annual Standards and Specifications (AS&S), attach the completed AS&S Entity Form. If the AS&S Entity is different from the operator identified in Section I. A., list the AS&S Entity Name. The AS&S entity is the entity or agency that holds the approved annual standards & specification. Please indicate if this project is also requesting a plan waiver. • AS&S Entity Form link: Annual Standards and Specifications Entity Information Form Rev 11/2020 PAGE 5 16 CONSTRUCTION GENERAL PERMIT (VAR10) REGISTRATION STATEMENT 2019 INSTRUCTIONS PLEASE DO NOT PRINT OR SUBMIT E. Billing information. If the person or entity responsible for billing/invoicing is different from the operator, please complete this section. If they are the same, leave this section blank. Section V. Certification. A properly authorized individual associated with the operator identified in Section I. A. of the Registration Statement is responsible for certifying and signing the Registration Statement. A person must physically sign the certification, a typed signature is unacceptable. State statutes provide for severe penalties for submitting false information on the Registration Statement. State regulations require that the Registration Statement be signed as follows per 9VAC25-880-70 Part III. K. 1.: a. For a corporation: by a responsible corporate officer. For the purpose of this part, a responsible corporate officer means: (i) A president secretary, treasurer, or vice-president of the corporation in charge of a principal business function, or any other person who performs similar policy -making or decision -making functions for the corporation, or (ii) the manager of one or more manufacturing, production, or operating facilities, provided the manager is authorized to make management decisions that govern the operation of the regulated facility including having the explicit or implicit duty of making major capital investment recommendations, and initiating and directing other comprehensive measures to assure long-term compliance with environmental laws and regulations; the manager can ensure that the necessary systems are established or actions taken to gather complete and accurate information for permit application requirements; and where authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures. b. For a partnership or sole proprietorship: by a general partner or the proprietor, respectively. c. For a municipality, state, federal, or other public agency: by either a principal executive officer or ranking elected official. For purposes of this part, a principal executive officer of a public agency includes: (i) The chief executive officer of the agency, or (ii) A senior executive officer having responsibilityfor the overall operations of a principal geographic unit of the agency. Section VI. Submittal Instructions. Submit this form to the VSMP Authority that has jurisdiction for your construction activity. The VSMP Authority may be either DEQ or your locality depending on the location and type of project. If your project is under the jurisdiction of a Local VSMP Authority, please contact the locality for additional submittal instructions. A blank area is provided for the Local VSMP Authoritys mailing address. Who is the VSMP Authority for my project? DEQ or the locality) • DEQ: DEQ is the VSMP Authority and administers permit coverage for land -disturbing activities that are: ➢ within a locality that is not a VSMP Authority; ➢ owned by the State or Federal government; or ➢ utilizing approved Annual Standards and Specifications. • The Locality: The local government (locality) is the VSMP Authority and administers permit coverage for all other projects not covered by DEQ as listed above. For these projects, please submit permit forms directly to the Local VSMP Authority. A list of Local VSMP Authorities is available on DEQ's website here: Local VSMP Authority List. DEQ'S CONSTRUCTION GENERAL PERM IT W ESSITE www.deg.viritinia.gov/Proerams/Water/StormwaterManagement/VSMPPermits/ConstructionGeneralPermit.as apxx Email the completed and signed form to: constructiongp@degxirginia. Rev 1112020 PAGE 6 16 0 Project Area: ±3.3 acres VPDES Registration Site Map - LOD Proffit Road Townhomes Stream WSSI #32316.01 NORTH 0 Waterbody cE Primary Construction Entrance Latitude of Primary CE 38.131363' Longitude of Primary CE:-78.431896' HUC12 Name: Jacobs Run -North Fork Rivanna River; South Fork Data Source: Albemarle County Digital Data Image Source: NearmapG - July 2022 'Area is based on GIS data, and does not reflect the legal acreages of the site. For exact LOD acreage, see approved plans. 0 200 Feet Onginal Scale: t "= 200' Wetland Studies and Solutions, Inc. a DAVEY1. company Exhibit 1 Section 2. Notice of general permit coverage (This notice is to be posted near the main entrance according to 9VAC25-880-70, Part II, section C.) (Provide a copy of the DEQ coverage letter when obtained) Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Section 3. Nature of activity (Provide a detailed narrative of the construction activities. Include or reference a construction schedule and sequence. Include any phasing.) This project proposes 40 single family attached townhomes. The land development, including Phase I & II E&S controls and the stormwater plan for the overall property will be completed by Riverbend Development (WPO202000017). Erosion and siltation control measures shall be provided in accordance with the approved erosion control plan and shall be installed prior to any clearing, grading or other construction. Greenwood Homes will install construction entrances and silt fence around graded lots prior to the start of townhome construction. All slopes and disturbed areas are to be fertilized, seeded and mulched. The maximum allowable slope is 2:1 (horizontal:vertical). Where reasonably obtainable, lesser slopes of 3:1 or better are to be achieved. Paved, rip -rap or stabilization mat lined ditch may be required when in the opinion of the County Engineer or designee it is deemed necessary in order to stabilize a drainage channel. All traffic control signs shall conform with the Virginia Manual for Uniform Traffic Control Devices. Unless otherwise noted all concrete pipe shall be reinforced concrete pipe - Class III. All excavation for underground pipe installation must comply with OSHA Standards for the Construction Industry (29 CFR Part 1926). Due to required distances from lot lines and structures as required by the NFPA, underground propane tanks may be prohibited. The information and data shown or indicated with respect to the existing underground utilities at or contiguous to the site are based on information and data furnished to the owner and engineer by the owners of such underground facilities or others. The owner or engineer shall not be responsible for the accuracy or completeness of such information or data. The contractor shall have full responsibility for confirming the accuracy of the data, for locating all underground utilities, for coordination of the work with owners of such underground utilities during construction, for the safety and protection thereof and repairing any damage thereto resulting from the work. All of these conditions shall be met at no additional cost to the owner. The contractor shall contact "Miss Utilities" of Virginia at 1-800-552-7001 prior to the start of work. When working adjacent to existing structures, poles, etc., the contractor shall use whatever methods that are necessary to protect structures from damage. Replacement of damaged structures shall be at the contractor's expense. The contractor shall be responsible for protecting all existing site structures from damage and coordinating work so that the owner can make necessary arrangements to modify/protect existing structures from damages.The contractor shall be responsible for notifying all utility owners, adjacent land owners whose property may be impacted and the Virginia Department of Transportation prior to completing any off -site work. Contractor shall notify and coordinate all work involving existing utilities with utility owners, at least 72 hours prior to the start of construction. All bare areas shall be scarified, limed, fertilized, seeded and mulched. All trees, saplings, brush, etc. shall be removed from within the right of way and the drainage easements. Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. Retaining walls require separate building permits. All water service lines, sanitary laterals, and sprinkler lines must be visually inspected by the Albemarle County Building Department from the main to the structure. Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Section 4. Erosion and Sediment Control Plan. (Provide a reduced, 11x17 copy of the latest Erosion and Sediment Control Plan. Do not reference only.) Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County / 532 \/ 1 \ 534 ----� ---- - - 532--- 52a \ - - - A Dense Trees \ LT \ - \ 530 / 530 SEQUENCE OF CONSTRUCTION - PHASE 3 1. INLET PROTECTION TO REMAIN UNTIL ALL WORK ONSITE IS COMPLETE. 2. APPLY PERMANENT SEEDING. 3. WHEN SITE IS STABILIZED, INSTALL STORMTECH CHAMBERS WITH THE GUIDANCE OF AN ADS REPRESENTATIVE. 4. CALL FOR FINAL INSPECTIONS. \ 36 / \ _� 1 \ 1 536 - - - i \ I / � 530 - \ PED o� II \ POLE / / S32 O POLE --OHU-OHU-I-OHU-CHU-CHU-CHU-ONE-pHU-CHU-pHU- HU- �OHU-pHU-OHU�pHU-OHU-OH S{U- N s2s, - L - \ POLE O- NEW 30'/ / 1 \ c 1 I 532 526 \ 526 - \ o \ \ % / \ \ \ RON o \ LIMITS OF ISTU ACE N22.24'08"E 482.68' w \ FOtO'D 2 .Ss / - _ / FOUNIRON 2 7 �32 x 4 34 - - X - X X - X - X - - o / Fa<OPOSED ROW A4D \ p CAP 2� \ 3 - - - - - - - - - - - - - 3150n, /� �1 �° Q \ / ■ `bEDICATION 35.5'-,WIDTH L I FROM OA CL 2750. LOT 31 " LT \ \ ,° - _ - - \ 1 I ■ ' I F R D FFE 528.00 00 , , T `S 1 ° ' ONE CAR 28 1.5%� I\ 28� Q30 - o / GARAGE UNIT S I `s so \ U �o \\w 3100 3150 3250 / _7 In .� u' c \ 1 j /� NEW 0 CSA- 28 00 29 00 30 EASEMENT � 30 x� \I S I o LOT 30 5/( a) `2 \ \ \ \ I 32 TS c DI SA 24 - 2% FFE 527.50 o s e sa \ )) \ 4 ' -Oltlf LQR 2T 1.00% 27z 2 6 \ \ \ LOT 37 LOT 38 L0� 39 LOT 40 GARAGE UI�1T g 28 \ LOT 32 LOT 33 LOT 34 LOT 35 LOT 36 FFE 531.50 FFE 532.00 FFE 32.50 FFE 533.00 S- _ \ �� 529.00 FFE 529.50 FFE 530.00 FFE 530.50 FFE 531.00 \ ONE CAR ONE CAR ONF CAR ONE CAR A4C \ e I I ONE CAR ONE CAR ONE CAR ONE CAR ONE CAR GARAGE UNIT GARAGE UNIT GARAGE UNIT GARAGE UNI I _ _ U \ 2 L STE / GARAGE\ \IT GARAGE UNIT GARAGE UNIT GARA`f3E UNIT GARAGE UNIT \ SLEE E / ry ° CD LOT 29 + 2% \ l FFE 527.50 o eb a 1 ,e 9 I \ - so I y = ONE CAR 275 3.3\ a6 7� X 6 00 \ / i - 2 e `�F I GARAGE UNIT \ ° J \ \ s° 3100 w z . o /,.. / 0 1 \ °o 30 31 a o� x \ 28 28so 29 29s� 30 ° . A - 5 2- ws - Go ws - - `�q -2690 FFE �52700 b•. �. o_ I \� b\ 6�°I 6� UO O m m �/ of rnl PTA \ cn --�-- N ONE CAR 2?o 2.19% 26. 2 44 { o`= I \ N I �J I �1 �� a i1j+ / ajjl / / / �1I j 000 rn I 1 "22 \ GARAGE UNIT $ N \ a ril \ j \ 28 1 \ s� o,Pa z I \ 27z5 2� ­2%z ­28zz \ 28se gal 0oz /0 . °' .a 10 a - a ° °EW:30'.ACSA'S,a �.a'S< z'.. 1e \ LOT 27 o `c d., o<2T•'' °' „.w <� 2%� 1R `y18�a gn t9z- :`° 4 / �X ,�� 35� \I 2\ FFE 527.00 °. 1 /9e N _ z <r _ - C r - ;T�E ° 30 \ ONE CAR 2%° 3.687 26io 0 5ao x4�. x 6 �i2 �iI .� "S - X 8 5- ' -,GARAGE UNIT I G RED \ - A90° NEW IV �R.IABLE TH .I W��p - -- 'ws W W5T6ttMWA"fi WNS' DIPW W W W W W L yV Vd Y? E o NEW 20' PRIVATE �2 8" MANA EMENT ES _ _ R _ - 7 ' A4B ++ C'�. II _ II 1.84% _7 . Q M ESIy�T �_.. .�Q - .C)-E I c X 11 1 A4A f 13+ TI'�+50,.00 \ 0 12+50.0 1 12 - �' o \ O 8" E 8� d _ _ L0535:50 I 1 \ \ x6" RED- \' F E IT i N _ X \ o PRIVATE Rl�.S3d+ A 2' DI- w FRAGE UN 3 24" HOPE ST RM a S27 s, RED, ,, \ \ A5 I / S 5 (TYP.) 34 1 GA S v \ - 86{ HP S - - \- - DI-3 - - 0% A3 WEIR WALL '6° ^V - \ ' �IdE'X�' a 31 x �� ► LO G SWE z o ° < FLEW o o 3 , ' \\ - - WM ws M 2LL VERLNA A s _ A E - -a ( 3 1 ra �'0535.00 p rNv so LOT 22 < I \ - ° 50 5 j� S 34 GAR GE UNIT c X 1 \ 26 FFE 527.00\8 a a A7 a w 1 1 cJn I ONE CAR 2?0 �26,e e Sae ➢ \ r o o o > 32 O�q 075 /z 3-114% I 1 4.32% x 6.1 ADS aN-1 M I_ GARAGE UNIT I m (TYP) \ ` " �ACKFL� LOT S \ I 1 I + LOT 16 ° ,° .y I d rs°. 9 00 0 o I 4.70% 7 FFE 528.00� �REVENTEf� yi d92, 1 3t G�VEARAGEZUNIT o az c x 1 TWO CAR I S26 99 'zti FFE, 5 4.5 n \ GARAGE UNIT 6' I es " S 90 UNIT o 2690 FFE0527 00 \ a: UNDERDRAII _ x so % ae > Iq 33 GAR`aE c X \\ o �55 a es - - 323 � m 3 9 \ ! 1\ ONE CAR 2! 3.10% ?6 2 5 GARAGE UNIT $ z / \ e.. I -- - oe \ LOT 10 2 z, 4 5% 7 ° LOT 17 ° J6 7n I x a ..1 32 FFE 532.50 O v \ �� FFE 528.00 x x ARAGE UNIT p� TWO CAR \ _ �' I LOT 4\ y ' o GARAGE UNIT \ 0o 93 3 IS S I 33 FFE 534UNIT Z _ a 11 0 FFE 527.00 0 v`„ $ -` o L . x Pj% . 3��\ -0 0 _ - 26so LOT 24 N \ J" cn I \ NEV f°D M-ESMTE I s> % GARAGE \ � I \ ■ � / -AONE CAR 522 �.-47%- 6. 2 5e a 1 m \P LO 11 OR T �yq \ 9B o \ ■ 2 53 4.51% 2T° LOT 18 '7a 73 ?� o SPE TION Q� 1a 32 FFE `�\32uNIT �S ,o�J'O FFE 528.50 y `� X AGE\ 1 CAR.� n GAR son �.32 �� o 4G o LOT 25 5/(T P.) L GARAGGE UNIT I99. I 6 �ee 1U / HP STORM o ■ I \ 11-�§15" 2?FFE 527.50 0n + 0 32e°33 %ONE CAR 275 3.76% 26. 2 GARAGE UNIT S ea ]° °° LOT 1250 Co FEE 50 �Ix.2 , / 31 32 FFE 532UNIT \ ws �a :2-Et 5.90% 28 TWO CAR 7 7 31 P X GARA / I\ I ■ LOT 5 \ \ I / 0o FFE 534 00 ■ / - 524 GARAGE UNIT / - 1� sz� N '� S 33 RAGE UNIT x \ o LOT 26 so ,]1 rn . , GA \ \ N / - 2% FFE 527.50 0 - a a2 - n - 32 5 6 S �/ 6 p0% ox ONE CAR 275 2.53% 6 o ' Z / 1 5 „ W S, c M 1 ■ \ I `-` GARAGE UNIT SJ °° of s� o L0532.50 t�s I A4 b 2 I 3.86% 28- _EF�528.50 // X?&, 7 I I 31 �. 32 FFE GARAGE UNIT oo Z I 1 ■ O I \ --- / �5/a,. WM -- ."�. g S 50 533.50 - I ws T11A0'C-AR- NE VARIABLE WIDTH `{+s LOT 6 I 'J1- c I 1 1 GARAGE UNIT STORMWATER a S 32 FFE UNIT ° ¢ TYP. ANAGEMENT ESMT -- ao , 1% GARAGE / 0�� I 32 6.49% c+r-30� 5. 9 1 1_1 s° LOT 14 b �- S 9 y X N I ■ 1 I 5 -Vs 2 �I 5.23% 2850 LOT 21 .7e 7ae 30 1 31 FFE 5NIT o NO 5DenseTree _ FFE 528.5 x2 GARAGE �7/FOUND - C TWO CAR _, 5.96% LOT - _ a &� FFE 533.50 7 x27 � - - � .> � � I � CA 5 gaz S �5 J0 (TYP.) GARA E UNIT II 1 -------- X2 __ _ - 526 l - -- - - -- - - .+ 7.59' 2"W 338.89' - - - - - - / a G / 31 T. � �'30 l 8.57 o I � ■ 1 / - - --�� TS J LOT 15 P�) 08 IIc,J \ s ■ Oq PS o,'e, FFE 53A.50 / _ - - - - - - - - -- - -- - - - 528 LIMIT$- O� �ISi-UR@Anl .28 X.4> . GARAGE �2,� $ \ LO533.00 2 C>_ -----_ 2 32 FFE _ _ GE UNIT Z \\- ■ 1 I 530 528 A9A1 1a8 I „ 5p 5 i� GA 2 c ■ 1 /-----------_ 528 �� 27 .0 % 2917 , 1 / A 4 69 c ■ IRON ■ 1 530 SET S26'O8'59"W 169.50' CA I I 1 - r - - - / Dense Trees 11 - s3o IRO c q \ -------- � ----- �1 � FOUND g7,5 -- - - - 532 ---\ 1 532 1 r \ \ 1 �q V \ I z \ 000�- \ I 20 0 20 0 60 Scale: 1 "=20' SOIL EROSION & SEDIMENT CONTROL SYMBOLS SYMBOL NO. TITLE KEY 3.02 CONSTRUCTION ENTRANCE CE X X 3.05 SILT FENCE SF 3.07 INLET PROTECTION IP 3.09 TEMPORARY DIVERSION DIKE DD [DRAWN TO SCALE] 3.13 TEMPORARY SEDIMENT TRAP ST 3A8 OUTLET PROTECTION OP p rye 3.31 TEMPORARY SEEDING TS 3.32 PERMANENT SEEDING PS 3.35 MULCH 3.39 DUST CONTROL DC LIMITS OF DISTURBANCE SHIMP ENGINEERING LAND PLANNING I SITE DESIGN I CIVIL ENGINEERING I PROJECT MANAGEMENT Design Focused Engineering 912 East High Stmet Phone: 434=-5140 Chenogesmile, VA 22902 shimp-engineenng.mm ,�N1�121 83��� ZONAL VSMP PLAN ALBEMARLE COUNTY, VIRGINIA PROFFIT ROAD TOWNHOMES SOUTH SUBMISSION: 2020.03.20 REVISION: 1) 2020.07.16 2) 2021.03.30 3) 2021.06.07 FILE NO. 18.041 E&SC PLAN PH 3 SHEET C7 OF 12 C7 Section 5. Stormwater Management Plan (Provide a reduced 11x17 copy of the latest stormwater management plan. Do not reference only.) Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County 540 535 530 525 520 515 510 505 Al CA 2) A3 A4 A5 A6 a 0 M M Nj + M 114 V. STR. A N - �- �' BOOED INV. IN 90 522.0 zrvt -__ - 0o 01 woe � ± 100-YR HYpRAIIILIG GRADE LINE 10-YR HYDRAULIC GRADE LINE - - - - - - - - a d z � N 1 - _ - `- - - - ---j -- _ _ SEP RIATION MA' FOS N12 MANIFOLD - -X• GRADE 1-0-D'f4--HYDRA1TLl GRADE LINE - - - 0o 1 w o + a a GRADE +- --_ - - - _ _ - - _ - - - - -_ _ _ - - - - - - - _ - _ - - - - ., P ------------ _ N No - " HP 94 38LF 39 ^ N 34.9 LF - 36„ - - - - - 97.26 LF 24" HDPE@ 2.41% - 1 v o 267.25LF - 24" HOPE O 1 0.80% rn 16 PLAT W Ua O Q �- ,P I ,17 > z >-W O w o Q 3 a o U Z U" o IN >N>� z 1 z 0 m a to 2 o Z Z > Rip p �, z - -zz I I z� � 500 10+00 10+50 11+00 1 STORM PROFILE Al -A6 C9 VER : =10 HORZ: 1"=20' A7 �AB� 540 535 530 525 520 515 510 505 A9 AlO 11+50 12+00 o� No 1_ 11 o+ %HYUKAULIC / nRADE LINE GRADE \ 3w¢. \z o� oo I wow 3 wo¢ -- z- - ----- / 12" MIN. / SEPARATION 1 - 53.04 -x. rn - - 29,61-1 - 15 `n `M° 53.27LF - 15" HDP HDPE 0.73% 20129E 15)" HDPE a 0.82% eo O C� ,`f ,`; > _ 2.22 " � o 4" SUMP z > a N o> ® > z - o> > z - z N U N > 10+00 10+50 11+00 11+50 2 STORM PROFILE A7-A10 C9 VERT:1"=10' HORZ: 1 "=20' 535 535 FROM A8 INTO A7 NSPECTION 1.3 FT OF I E =522.50 PORT (TYP.) STONE COVER 530 530 l525_ __ _ ___ L ___ ___ ___ _ 525 N-12 MANIFOLD MC-450O- n � n N IE ISOLATOR ROW IL END CAP \• 520 0_-___ .___.___. (TYP) iiiI ii520 18 ADS N-12 515 515 INV, OUT TO OTHER CHAMBERS BASE SOLATOR I MC-4500 ii A6 INV.=519.50 ROW INV. _ I VARIABLE LLINtIH E _ 519.80 _1. (TYR) INV 50 510 510 10+00 10+50 11+00 11+50 s STORMTECH PROFILE C9 VERT:1"=10' HORZ: 1 "=20' 545 540 535 530 525 520 515 510 505 C9 VERT: HORZ: 12+50 540 STONE TOP 525.81 535 CHAMBER ROW TOP 524.51 530 525 1 . C O 520 515 13+00 13+50 14+00 14+50 15+00 A6 ADS GEOSYNTHETIC 601T NON -WOVEN GEOTEXTILE A7 53 4 18" ADS N-12 AROUND ALL STONE LAYERS INSPECTION PORT IF MANIFOLD GROUND ELEV. 528.05' N 1.30' 530 x n STONE TOP 525.80' x O -� #3 STONE ISOLATOR ROW TOP 524.80' 52w~ OLATOR W o MCS 4 TYP.)Ln - OLATOR R W 52 TOR BOTTOM 519.8' 51 6" U ERDRAIN INV. 517.50' 5' #3 STO BER BOTTOM 519.5' oa 8.33' STONE BOTTOM 517.50' 51Q- z o> 24" SUMP 24" SUMP ? z 510 3 STORMTECH CHAMBERS SECTION DETAIL Cg SCALE: 1"=5' 505 12+00 10+00 10+50 11 + 00 11 +50 s SANITARY PROFILE Z4-Z4a C9 VERT:1"=10' A4 HORZ: 1"=20' MR.. 540 61NIE 530 6YA ly 515 510 505 12+00 I-3C TOP 525.77 100-YR WSE 524.68 10-YR WSE 523.27 WEIR TOP 523.40 a 2-YR 1-YR WSE 521.23 WSE 520.86 0 24x5.5" ORIFICE INV. 520.90 4 - 2.3" z z= ORIFICE INV. 516.72 PROVIDE A TRASH RACK FOR THIS ORIFICE 8 WEIR WALL DETAIL STR. A4 Cg SCALE:1"=5' 8" ROOFDRAIN� 5' MH-1 M ACCESS ON EACH SIDE OF THE WEIR 36" HP PIPE 24 HP PIPE 12' DI-3 W/ WEIR WALL monism LONG SWEEP STR. A4 PLAN DETAIL Cg SCALE: 1"=10' 35 30 ?5 0 5 0 15+50 16+00 I g" SDR-26 @ 5.73% 133.05LF NCE 10+50 11+00 a SANITARY PROFILE Z4-Z4b C9 VERT:1"=10' HORZ: 1"=20' PROFFIT ROAD TOWNHOMES SOUTH LD-229 STORM DRAIN DESIGN COMPUTATIONS F. To Catch. Runoff Inc A. ToC Tooel Toot UP Do Pipe Inv Pipe Pipe Veloeity Flowtose, Point point Area Cod AC AC httensi Flow cfs ivveH Invert Len SI mter Diae Ca i Inc in1hr El 0ft % cfa Poe 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 All AID 0.47 0.47 0.22 0.22 5.00 5.17 1.14 5 52.5 53. 4.71% 15 15.2 .4 0.12 AID A9 0.22 5.12 5.14 1.13 524M 524.30 20.29 0.99% 15 7.2 4.3 0.08 A9C A9B 0.33 0.70 0.23 0.23 5.08 5,15 1,18 527.37 526.76 88.36 069% 15 5.8 3.7 040 A9B A9A 0.23 5.40 5.07 1.17 526.56 524.90 63.76 2.W% 15 11.3 5.9 0.18 A9A A9 0.23 5.18 5.12 1.18 524.90 524.00 118.88 0.76% 15 6.1 3.8 0.52 A9A1 A9A 0.23 075 OA7 0.1] 5.W 5.17 0.89 525.50 524M 94.99 0]l% 15 5.1 3.8 0.37 A9 A8 0.45 5.52 5.04 2.27 524.10 523.70 53.27 0.75% 15 6.8 5.0 0.18 A A7 0.35 0.86 0,30 0]5 5.18 5.12 3.85 3.38% .05 Nine: Detentlnn Svete,n Between A7 X' A6 A6 A5* _ . 0.26% A5 A4* 517.11 516.87 94,38 0,25% 36 A4H A4G O.W3 GAB DO@ 0002 5.00 5.17 0.01 524.90 524.51 39.00 1.00% 6 0.2 0.5 1.26 AtG A4F O.W3 0.W 0.002 0.002 6.26 4.87 0.01 524.41 523.80 61 I.W% 6 0.2 0.5 L97 A4F ME 0.t103 0.90 0.902 TOM 6.97 4.72 0.01 523.70 523.29 41 1.W% 6 0.2 0.5 1.32 ME A4 0.902 0002 6.32 4.86 0.01 523.19 52290 29 100% 6 0.2 0.5 0.94 A4D A4C 0.003 0.90 O.W2 O.W2 5.00 5.❑ 0.01 524.90 524.51 39 LW% 6 0. 0.5 1.26 A4C A48 O.W3 M" O.W2 B002 6.26 4.87 0.01 52.41 523SO 61 LW% 6 0.5 1.97 ME A4A o.W3 0.90 O.W2 0.002 6.97 4.72 0.01 523.70 523.29 41 LW% 6 0.2 0.5 1.32 MA A4 0.902 0.002 6,32 4.86 0.01 523.19 522,88 31 1.W% 6 0.2 0.5 I.W A4** A3 1054 tut 096 0.76 6.00 4.93 8.31 516.72 516.10 77.42 0.80% 24 2L9 6.5 0.20 A3** A2 0.76 5.20 5.12 8,31 515.90 514b) 267.25 0.71% 24 Del 5.7 0.78 A2** At 0.76 5.78 4.98 8.31 513.45 511,11 97.26 2.41% 24 38.0 9.7 0.04 "Pi •Sizin not competent as i used for.aarae is the l0.r fmmhdmcad+ the Accumi lined AC=755�0.76=8.31 PROFFIT ROAD TOWNHOMES SOUTH LD-204 Stormuater III Computadom Inlets on Dade Only Sag Inlets Only s` c rn S m 5 U¢ U P4 U - d a d d z i ai O o a n U 'e E 2 L� e e d e d IL 1 2 3 5 6 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 (R) (ac) (m/hr) (-is) (°R) I C/9 0 C/9 (ft) (ft) (eft) (-fi) (ft) (ft) (ft) All DI-7 3.5 1 0.47 1 0.47 0.22 4.0 0.88 0.00 1 0.88 0.020 0.04 0.04 0.09 1 6.35 6.5 1.43 0.00 1.43 - 0.13 - - 8.11 A8 DI-313 12 0.35 0.86 0.30 4.0 1.21 0.62 1.82 0.020 0.08 0.02 0.03 3.36 0.26 IM0"/0 1.82 0.00 6.5 1.96 0.24 2.20 3.44 0.27 100.0% 2.20 0.00 A5 DI-313 12 0.73 0.71 0.51 4.0 2.05 0.00 2.05 0.020 OM 0.02 0.02 0.26 0.5 0.53 6.88 6.5 3.33 0.00 333 0.32 0.5 0.64 9.67 A4 DI-3C 12 1 1.05 1 0.72 0.76 4.0 1 3.04 0.00 1 3.04 0.026 0.08 1 0.02 0.02 1 0.27 0.5 0.53 7.06 6.5 4.94 0.00 4.94 0.31 0.5 0.61 9.03 A9C DI-3C 6 0.33 0.70 0.23 4.0 0.92 0.00 092 0.026 0.08 0.02 0.02 0.12 0.5 0.24 1.45 6.5 1.49 0.00 1.49 0.17 0.5 0.33 2.00 A9A1 DI-3A 4 0.23 0.75 0.17 4.0 0.69 0.00 0.69 0.020 0.08 0.03 0.05 3.21 0.19 89.8% 0.62 0.07 0.27 0.5 0.53 7.06 6.5 1.12 0.00 1.12 3.55 0.22 78.7% 0.88 0.24 1 0.31 1 0.5 0.61 9.03 TABLE 1, RECOMMENDED MINIMUM TRENCH WIDTHS HP STORM TRENCH INSTALLATION DETAIL MIN. COVER TO MIN. COVER TO RIGID PAVEMENT, H FLEXIBLE PAVEMENT, H FINAL BACKFILL INITIAL SPRINGLINE UBACKFILL MIN. TRENCH PIPE DIAM. WIDTH 12" 30" 300mm 762mm 15" W, 375mm 864mm 18" 39' 450mm 991mm 24" 48" 800mm 1219mm 30" 56" 750mm 1422men 36" 64" 900mm 1626mm 42" 72" 1050mm 1829mm 48" 80" 12OOmm 2032mm 60" 96" 1500mm 2438mm J- HAUNCH TABLE 2, MINIMUM RECOMMENDED COVER BASED ON VEHICLE LOADING CONDITIONS BEDDING 4" FOR 12%24" PIPE 8" FOR 30"-60" PIPE MIN TRENCH WIDTH SUITABLE ( (SEE TABLE) FOUNDATION NOTES: 1. ALL PIPE SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM D2321, "STANDARD PRACTICE FOR UNDERGROUND INSTALLATION OF THERMOPLASTIC PIPE FOR SEWERS AND OTHER GRAVITY FLOW APPLICATIONS', LATEST ADDITION, SURFACE LIVE LOADING CONDITION HEAVY CONSTRUCTION PIPE DIAM. H-25 (75T AXLE LOAD)' 12"-48' 12" 48" 300mm-1200mm) 305mm 1219mm 60" 24" 60" 1500mm 610mm 1524mm ' VEHICLES IN EXCE S OF 75T MAY RE UIRE ADDITI NAL VER WITH THE EXCEPTION THAT THE INITIAL BACKFILL MAY EXTEND TO THE CROWN OF THE PIPE. SOIL CLASSIFICATIONS TABLE 3, MAXIMUM COVER FOR ADS HP STORM PIPE, 8 ARE PER THE LATEST VERSION OF ASTM D2321. CLASS IVB MATERIALS (MH, CH) AS DEFINED IN PREVIOUS VERSIONS OF ASTM D2321 ARE NOT APPROPRIATE BACKFILL MATERIALS. 2. MEASURES SHOULD BE TAKEN TO PREVENT MIGRATION OF NATIVE FINES INTO BACKFILL MATERIAL, WHEN REQUIRED. 3. FOUNDATION: WHERE THE TRENCH BOTTOM IS UNSTABLE, THE CONTRACTOR SHALL EXCAVATE TO A DEPTH REQUIRED BY THE ENGINEER AND REPLACE WITH SUITABLE MATERIAL AS SPECIFIED BY THE ENGINEER. AS AN ALTERNATIVE AND AT THE DISCRETION OF THE DESIGN ENGINEER, THE TRENCH BOTTOM MAYBE STABILIZED USING A GEOTEXTILE MATERIAL. 4. BEDDING: SUITABLE MATERIAL SHALL BE CLASS I, II, III, OR IV. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. COMPACTION SHALL BE SPECIFIED BY THE ENGINEER IN ACCORDANCE WITH TABLE 3 FOR THE APPLICABLE FILL HEIGHTS LISTED. UNLESS OTHERWISE NOTED BY THE ENGINEER, MINIMUM BEDDING THICKNESS SHALL BE 4" (100mm) FOR 12"-24" (3D0mm-600mm) DIAMETER PIPE; 6" (150mm) FOR 30"-60" (750mm-1500mm) DIAMETER PIPE. THE MIDDLE 1/3 BENEATH THE PIPE INVERT SHALL BE LOOSELY PLACED. PLEASE NOTE, CLASS IV MATERIAL HAS LIMITED APPLICATION AND CAN BE DIFFICULT TO PLACE AND COMPACT; USE ONLY WITH THE APPROVAL OF A SOIL EXPERT. 5. INITIAL BACKFILL: SUITABLE MATERIAL SHALL BE CLASS 1, II, III, OR IV IN THE PIPE ZONE EXTENDING TO THE CROWN OF THE PIPE. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. MATERIAL SHALL BE INSTALLED AS REQUIRED IN ASTM 02321, LATEST EDITION. COMPACTION SHALL BE SPECIFIED BY THE ENGINEER IN ACCORDANCE WITH TABLE 3 FOR THE APPLICABLE FILL HEIGHTS LISTED. PLEASE NOTE, CLASS IV MATERIAL HAS LIMITED APPLICATION AND CAN BE DIFFICULT TO PLACE AND COMPACT; USE ONLY WITH THE APPROVAL OF A SOIL EXPERT. S. MINIMUM COVER: MINIMUM COVER, H, IN NON -TRAFFIC APPLICATIONS (GRASS OR LANDSCAPE AREAS) IS 12" (300mm) FROM CLASS I CLASS II CLASS III CLASS N PIPE DIA COMPACTED 95% 90% 85% 195% 90% 95% 12" 41 28 21 16 20 16 16 (300mm) (12.5m) (8Sm) (6.4m) (4.9m) (6.1m) (4.9m) (4.9m) 15" 42 29 21 16 21 16 16 (375mm) (12.8m) (8.8m) (6Am) (4.9m) (6Am) (4.9m) (4.9m) 18" 44 30 21 16 22 17 16 (450mm) (13.4m) (9.1m) (6.4m) (4.9m) (6.7m) (5.2m) (4.9m) 24" 37 26 18 14 19 14 14 (BOOmm) (11.3m) (7.9m) (5.5m) (4.3m) (5.8m) (4.3m) (4.3m) 30" 39 27 19 14 19 15 14 (750mm) (IIBI (8.2m) (5.8m) (4.3m) (5.8m) (4.6m) (4.3m) 36" 28 20 14 10 14 11 10 (900mm) (8.5m) (6.1m) (4.3m) (3.Om) (4.3m) (3.4m) (3.Om) 42" 30 21 14 10 15 11 10 (1050mm) (9.1m) (6Am) (4.3m) (3.0m) (4.6m) (3.4m) (3.0m) 48' 29 20 14 9 14 10 70 (12001 (8.8m) (6.1m) (4.3m) (2.7m) (4.3m) (3.Om) (3.Om) 60' 29 20 14 9 14 10 9 (16001 (8.8m) (6.1m) (4.3m) (2.7m) (4.3m) (3.Om) (2.7m) THE TOP OF PIPE TO GROUND SURFACE. ADDITIONAL COVER MAY BE REQUIRED TO PREVENT FLOTATION. FOR TRAFFIC FILL HEIGHT TABLE GENERATED USING AASHTO SECTION 12, LOAD APPUCATIONS; CLASS I OR II MATERIAL COMPACTED TO 90% SPD AND CLASS III COMPACTED TO 95%SPD IS REQUIRED. RESISTANCE FACTOR DESIGN (LRFD) PROCEDURE WITH THE FOLLOWING FOR TRAFFIC APPLICATIONS, MINIMUM COVER, H, IS 12" (300mm) UP TO 48" (1200mm) DIAMETER PIPE AND 24" (600mm) OF ASSUMPTIONS: COVER FOR 60" (1500mm) DIAMETER PIPE, MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT NO HYDROSTATIC PRESSURE OR TO TOP OF RIGID PAVEMENT. UNIT WEIGHT OF SOIL (ys)=120 PCF 7. FOR ADDITIONAL INFORMATION SEE TECHNICAL NOTE 2.04. 6 REV. MAXIMUM COVER HEIGHTS RIND 01/11117 000mans. we REV. DESCRIPTION BY MI DHMD ADVANCED DRAINAGE SYSTEMS, INC. ('ADS') HAS PREPARED THIS DETAIL BASED ON INFORMATION PROVIDED TO ADS. THIS DRAW ING IS INTENDEDTODEPIMrHECOMPONENTS MQUESTED. ADS HAS NOT PERFORMED ANY ENGINEERING OR DESIGN SERVICES FOR THIS PROJECT, NOR HAS An INDEPENDENTLY VERIFIED THE INFORMATION SUPPLIED. THE INSTAUATION DETAILS PROVIDED HEREIN ARE GENERAL TRENCH INSTALLATION 4"0 TRUEMAN BLVD AR RECOMMENDATIONS AND E NOT SPECIFIC FOR THIS PROJECT. THE DESIGN ENGINEER SHALL REVIEW THESE DETAILS PRIOR TO DETAIL () HP STORY` HILLIARD, OHIO 4=6 CONSTRUCTION. IT IS THE DESIGN ENGINEERS RESPONSIBILITY TO ENSURE THE DETAILS PROVIDED HEREIN MEETS OR EXCEEDS THE u APPLICABLE NATIONAL,STATE, OR LOCAL REQUIREMENTS AND TO ENSURE THAT THE DETAILS PROVIDED HEREIN ARE ACCEPTABLE FOR THIS nwurenowru<earere,�z PROJECT. DRAWING NUMBER: ST0.101D � Z4b 540 535 530 525 520 515 510 505 I I I 500 16+50 535 7f1f, SHIMP ENGINEERING LAND PLANNING I SITE DESIGN I CIVIL ENGINEERING I PROJECT MANAGEMENT Design Focused Engineering 912 East High Street Phone: 434-227-51Q Charlottesville, VA 22902 shim"ngineenng.com VSMP PLAN ALBEMARLE COUNTY, VIRGINIA PROFFIT ROAD TOWNHOMES SOUTH SUBMISSION: 2020.03.20 REVISION: 1) 2020.07.16 2) 2021.03.30 3) 2021.06.07 FILE NO. PROFILES SHEET C9 OF 12 C9 ABA ABC ACCEPTABLE FILL MATERIALS: STORMTECH MC-4500 CHAMBER SYSTEMS AASHTO MATERIAL MATERIAL LOCATION DESCRIPTION COMPACTION / DENSITY REQUIREMENT CLASSIFICATIONS FINAL FILL: FILL MATERIAL FOR LAYER'D' STARTS FROM THE PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED D TOP OF THE'C' LAYER TO THE BOTTOM OF FLEXIBLE ANY SOIUROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS. NIA INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND PAVEMENT OR UNPAVED FINISHED GRADE ABOVE. NOTE THAT CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS. PREPARATION REQUIREMENTS. PAVEMENT SUBBASE MAY BE PART OF THE'D' LAYER AASHTO M145' INITIAGRANULAR FILL: FILL MATERIAL FOR LAYER'E STARTS FROM THE WELL -GRADED SOIUAGGREGATE MIXTURES 35% FINES OR '°'-1"°'-2.4''°'-3 BEGIN COMPACTIONS AFTER 24 800 mm OF MATERIAL OVER ( ) TOP O TOP OF THE EMBEDMENT STONE ('B' LAYER) TO 24" (800 mm) PROCESSED AGGREGATE. _ THE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN C ABOVE THE TOP OF THE CHAMBER. NOTE THAT PAVEMENT OR 12' j300 ri MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR SUBBASE MAY BE A PART OF THE'CLAYER. MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THIS - WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FOR LAYER. AASHTO M43' PROCESSED AGGREGATE MATERIALS. 3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10 EMBEDMENT STONE: FILL SURROUNDING THE CHAMBERS AASHTO M43' B FROM THE FOUNDATION STONE ('A' LAYER) TO THE'C' LAYER CLEAN, CRUSHED, ANGULAR STONE 3.4 NO COMPACTION REQUIRED. ABOVE. A FOUNDATION STONE: FILL BELOW CHAMBERS FROM THE CLEAN, CRUSHED, ANGULAR STONE AASHTO M43' PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE.za SUBGRADE UP TO THE FOOT (BOTTOM) OF THE CHAMBER. 3,4 PLEASE NOTE: 1. THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE". 2. STORMTECH COMPACTION REQUIREMENTS ARE MET FOR LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 9" (230 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR. 3. WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAILING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR COMPACTION REQUIREMENTS. 4. ONCE LAYER'C' IS PLACED, ANY SOIUMATERIAL CAN BE PLACED IN LAYER'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER 'C' OR'D' AT THE SITE DESIGN ENGINEER'S DISCRETION. PERIMETER STONE (SEE NOTE 6) EXCAVATION WALL (CAN BE SLOPED OR VERTICAL) 12" (300 mm) MIN ADS GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILE ALL AROUND CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS MC-3500 END CAP SUBGRADE SOILS (SEE NOTE 4) \\ •TO BOTTOM OF FLEXIBLE \ INSTALIATIONSWHERERILITIN - - _ - INCRE45E COVET 9" (230 mm) MIN PAVEMENT LAYER (DESIGNED BY SITE DESIGN ENGINEER) AEm. FOR UNPAVED T MVEHICLESMAYOCCUR 1' (750IT). - 24" (600 mm) MIN" 12" (300 ri MIN y 60. (15251 7.0' (2.1 m) MAX --7T-IDEPTH OF STONE TO BE DETERMINED �I (ij_T-lu- _ BY SITE DESIGN ENGINEER 9" (230 mm) MIN 100"(2540 mm) 12'(300 mm) MIN NOTES: 1. CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418-16a,'STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS' CHAMBER CLASSIFICATION 60x101 2. MC4500 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 3. THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS. 4. PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS. 5. REQUIREMENTS FOR HANDLING AND INSTALLATION: • TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING, CHAMBERS SHALL HAVE INTEGRAL, INTERLOCKING STACKING LUGS. • TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL, THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE LESS THAN 3. • TO ENSURE THE INTEGRITY OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT AS DEFINED IN SECTION 6.2.8 OF ASTM F2418 SHALL BE GREATER THAN OR EQUAL TO 500 LBS/IN/IN. AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73- F / 23' C), CHAMBERS SHALL BE PRODUCED FROM REFLECTIVE GOLD OR YELLOW COLORS. UNDERDRAIN DETAIL NTS STORMTECH CHAMBER )RMTECH END CAP 'LET MANIFOLD FOUNDATION STONE BENEATH CHAMBERS ADS GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILE STORMTECH END CAP FOUNDATION STONE BENEATH -CHAMBERS i ADS GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILE _ITE DESIGN ENGINEER 4" (100 mm) TYP FOR SC-310 & SC-16OLP SYSTEMS 6" (150 mm) TYP FOR SC-740, DC-780, MC-3500 & MG4500 SYSTEMS MC -SERIES END CAP INSERTION DETAIL NTS T STORMTECH END CAP 12" (300 mm) MIN INSERTION MANIFOLD STUB MANIFOLD HEADER 12"(300 mm) MIN INSERTION NOTE: MANIFOLD STUB MUST BE LAID HORIZONTAL FOR A PROPER FIT IN END CAP OPENING. MC-4500 TECHNICAL SPECIFICATION NTS CREST STIFFENING RIB CREST VALLEY WEB STIFFENING RIB 1 UPPER JOINT OORRI IRATION FOOT WALL tWIwJWEJOLstaglLaw LLU -'ORATED L LOWER JOINT CORR. 100.0" (2540 mm) BUILD ROW IN THIS DIRECTION I~ 90 2" (2291 mm) .� ERDRAIN nr SECTION B-B 12" (300 mm) MIN SEPARATION MANIFOLD HEADER MANIFOLD STUB - 1 30.7" 48.3" (781 mm) 52.0" INSTALLED (1227 mm) (1321 1 INSTALLED NOMINAL CHAMBER SPECIFICATIONS SIZE (W X H X INSTALLED LENGTH) 100.0" X 60.0" X 48.3" - (2540 mm X 1524 mm X 1227 mm) CHAMBER STORAGE 106.5 CUBIC FEET (3.01 mP) MINIMUM INSTALLED STORAGE" 162.6 CUBIC FEET (4.60 m") WEIGHT 130.0 Ibs. (59.0 kg) NOMINAL END CAP SPECIFICATIONS - 35.1" SIZE (W X H X INSTALLED LENGTH) 90.2" X 59.4" X 30.7" (2291 mm X 1509 mm X 781 mm) - (891 mm) 1` END CAP STORAGE 35.7 CUBIC FEET (1.01 m") MINIMUM INSTALLED STORAGE" 109.7 CUBIC FEET (3.08 Ph-) WEIGHT 135.0 Ibs. (61.2 kg) 'ASSUMES 12" (305 mm) STONE ABOVE, 9" (229 mm) STONE FOUNDATION AND BETWEEN CHAMBERS, 12" (305 mm) STONE PERIMETER IN FRONT OF END CAPS AND 40% STONE POROSITY. STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B" STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T" END CAPS WITH A WELDED CROWN PLATE END WITH "C" L END CAPS WITH A PREFABRICATED WELDED STUB END WITH "W" PART # STUB B C B MC4500REPE06T 6"(150 mm) 42.54' (1.081 m) - MC4500REPE068 - 0.86" (22 mm) MC450ORFPE08T 8" (200 ri 40.50' (1.029 m) -. MC450OREPEOBB -• 1.01" (26 mm) MC450GREPEIOT 10"(250 mm) 38.37" (975 mm) - MC4500REPE108 --- 1.33" (34 mm) MC450OREPE12T 12" (300 mm) 35.69" (907 mm) MC450OREPE12B -- 1.55" (39 mm) - MG450OREPEIST iS (375 mm) 32.72"(831 mm) - MC4500REPE156 - 1.70" (43 mm) MC450DREPE18TC 18" (450 mm) 29.36' 46 mm (7 ) - M045REPE18 MC45W00REPE18BC - 1.97' (50 mm) MC4WOREPE18BW MC450DREPE24TC 24" (600 mm) 23.05" (585 mm) - MC450OREPE24TW MG450OREPE24BC - 2.28" (57 mm) MG45COREPE24BW MG450OREPE30BC 30" (750 mm) -- 2.95" (75 mm) MC450OREPE36SC 36" (9W mm) -- 3.25" (83 rI MC45WREPE42BC 42' (1050 mm) _ - 3.55' (90 mm) NOTE: ALL DIMENSIONS ARE NOMINAL nm)I CUSTOM PRECORED INVERTS ARE AVAILABLE UPON REQUEST. INVENTORIED MANIFOLDS INCLUDE 12-24" (300.600 mm) SIZE ON SIZE AND 1548" (375-1200 mm) ECCENTRIC MANIFOLDS. CUSTOM INVERT LOCATIONS ON THE MC4500 END CAP CUT IN THE FIELD ARE NOT RECOMMENDED FOR PIPE SIZES GREATER THAN 10" (250 mm). THE INVERT LOCATION IN COLUMN'B' ARE THE HIGHEST POSSIBLE FOR THE PIPE SIZE. 545 540 535 530 525 520 515 510 0 • r = : ' - ISIIIIIIIIIIIIIII •' -i-__ � _ _ - �� ��4ygi - - Yi• 1� m� 9+50 10+00 10+50 1 STORM PROFILE A9-A9C C10 VERT: 1"=10' HORZ: 1"=20' COVER PIPE CONNECTION TO END CAP WITH ADS GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILE STORMTECH HIGHLY RECOMMENDS FLEXSTORM PURE INSERTS IN ANY UPSTREAM STRUCTURES WITH OPEN GRATES CATCH BASIN OR MANHOLE SUMP DEPTH TBD BY SITE DESIGN ENGINEER (24" [600 mm] MIN RECOMMENDED) 11 +00 MC-4500 CHAMBER 24" (600 mm) HOPE ACCESS PIPE REQUIRED USE FACTORY PRE -CORED END CAP PART #: MC450OREPE24BC OR MC450OREPE24BW MC-4500 ISOLATOR ROW DETAIL NTS INSPECTION & MAINTENANCE STEP 1) INSPECT ISOLATOR ROW FOR SEDIMENT A. INSPECTION PORTS (IF PRESENT) A.1. REMOVE/OPEN LID ON NYLOPLAST INLINE DRAIN A.2. REMOVE AND CLEAN FLEXSTORM FILTER IF INSTALLED A.3. USING A FLASHLIGHT AND STADIA ROD, MEASURE DEPTH OF SEDIMENT AND RECORD ON MAINTENANCE LOG A.4. LOWER A CAMERA INTO ISOLATOR ROW FOR VISUAL INSPECTION OF SEDIMENT LEVELS (OPTIONAL) A.5. IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3. B. ALL ISOLATOR ROWS B.I. REMOVE COVER FROM STRUCTURE AT UPSTREAM END OF ISOLATOR ROW B.2. USING A FLASHLIGHT, INSPECT DOWN THE ISOLATOR ROW THROUGH OUTLET PIPE i) MIRRORS ON POLES OR CAMERAS MAY BE USED TO AVOID A CONFINED SPACE ENTRY I!) FOLLOW OSHA REGULATIONS FOR CONFINED SPACE ENTRY IF ENTERING MANHOLE B.3. IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3. STEP 2) CLEAN OUT ISOLATOR ROW USING THE JETVAC PROCESS A. A FIXED CULVERT CLEANING NOZZLE WITH REAR FACING SPREAD OF 45" (1.1 m) OR MORE IS PREFERRED B. APPLY MULTIPLE PASSES OF JETVAC UNTIL BACKFLUSH WATER IS CLEAN C. VACUUM STRUCTURE SUMP AS REQUIRED STEP 3) REPLACE ALL COVERS, GRATES, FILTERS, AND LIDS; RECORD OBSERVATIONS AND ACTIONS. STEP 4) INSPECT AND CLEAN BASINS AND MANHOLES UPSTREAM OF THE STORMTECH SYSTEM. NOTES 1. INSPECT EVERY 6 MONTHS DURING THE FIRST YEAR OF OPERATION. ADJUST THE INSPECTION INTERVAL BASED ON PREVIOUS OBSERVATIONS OF SEDIMENT ACCUMULATION AND HIGH WATER ELEVATIONS. 2. CONDUCT JETTING AND VACTORING ANNUALLY OR WHEN INSPECTION SHOWS THAT MAINTENANCE IS NECESSARY. wv-z 545 540 I 535 w 530 Z 525 520 515 11+50 OPTIONAL INSPECTION PORT IbNLS'.IT17�\I9GL7:19 TWO LAYERS OF ADS GEOSYNTHETICS 315WTM WOVEN GEOTEXTILE BETWEEN FOUNDATION STONE AND CHAMBERS 10.3' (3.1 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS 12+00 IxFlx C11.4'N I.IL111 x 1Nr. BMIT TRASH RACK 12+50 545 540 535 530 525 520 515 510 13+00 New Trash Rack- 1" Holes • 30% Opening Area • °De° p eeeo °ae•°,eOye • a••da°OQ°ee•o eeo000e0 OO OOO OOO °De ee %p 0e• a O O C O O O W aW� o°°aBa°• O O C I.n11N01'll' 12,M OOOOOC 00000C I1P'R- nanxll'LM: 00000C 0O0C IIN i0I1 ; 1-ni;"P$+n. 000 O C. ;i.irn •RNx1. • r' .. • .un.n .nn ..P,1.."d Po-". Typ. Front Section ..xx n,i x lilll'N xlnlrrl rxl ).^n+lx /i" P "nA • Ilnx \1•r' 11111 .iln 1' nn. unJ nrnln xr an ..r HP"I�(��" 2 5" ORII C 1 Q NOT TO SCALE a E�IL�I� +1j0 10+00 10+50 s STORM PROFILE A9A-A9A1 C10 VERT:1"=10' HORZ: 1"=20' TICK COAT THE PROPOSED CONSWAICTION .PINT EXISTING ASPHALT LAYERS PROPOSED ASPHALT LAYERS -------- EXISTING SUBBASE-------- PROPOSED SUBBASE COMPACTED SJBGRADE CONSTRUCTION JOINT DETAIL ® REMOVE EXISTING ASPHALT LAYERS TO EXISTING SUBBASE AND REPLACE WITH PROPOSED ASPHALT WIDENING LAYERS ® PROPOSED MMMUM I% NCH THICK ASPHALT SURFACE COURSE (SEE NOTE 5) " LgMRA 12 INCHES. OR C(SATER AS NECESSARY TO ABUT THE FILL THICKNESS OF EXISTING ASPHALT LAYERS AS DETERMINED BY CORES :SEE NOTE 3) NOTES: 1. ASPHALT PAVEMENT WIDENING SHALL HAVE A PAVEMENT DESIGN N ACCORDANCE WRH CURRENT VDOT PROCEDURES AND BE APPROVED BY THE ENGINEER. 2. THE PAVEMENT DESIGN FOR ASPHALT PAVEMENT WIDENING SHALL MEET OR EXCEED THE DEPTHS AND TYPES OF THE LAYERS OF EXISTING PAVEMENT. SUBSURFACE DRAINAGE OF THE EXISTING AND PROPOSED PAVEMENT SHALL BE ADDRESSED IN THE PAVEMENT DESIGN. 3. A MINIMUM OF THREE CORES SHALL BE TAW ALONG THE CENTER OF THE ADJACENT TRAVEL LANE TO CETERMIY THE TYPE AND THICKNESS OF EXISTING PAVEMENT LAYERS. THESE CORES STALL BE SPACED NO MORE THAN 500 FEET MART. 4. THE ADJPLENT TRAVEL LANE SHALL BE MILLED A MINIMUM DEPTH OF 1 %iE INCHES NO REPLACED WITH SURFACE AN ASPHALT SFACE COURSE TO MATCH THE PROPOSED PAVEMENT WIDENING SURFACE COURSE. UNLESS WAVED BY iK ENGINEER. 5. WE ENGINEER MAY MIME THE MILLING DEPTH OF THE EXISTING PAVEMENT TO SE ADJUSTED TO ACHIEVE AN ACCEPTABLE PAVEMENT CROSS-ADPE AND EFFECTIVE SUEACE DRANAGE. G. EXISTING PAVEMENT MARKPXCS AND MARKERS WITHIN THE PROJECT UNITS SILL BE RESTORED SUBJECT TO THE APPROVAL DF THE ENGINEER. 7. FINAL TRANSVERSE PAVEMENT RE -IN SHALL CONFIRM TO THE REQUIREMENTS OF SECTION 315.05(c) IF THE SPECIICATDNS EXCEPT THAT ALL JOINTS AT TIE-N LOCATIONS SHALL BE TESTED USING A V FOOT STRAGHTEDGE N ACCORDANCE WITH THE REOUREMENTS OF SECTION 31SO7001 OF THE SPECIFDATONS. END -SECTION 12' - 60'' P _NUB END ON OUTLET END SECTIONS SPOUT END ON HET EN SECU N 1X x CONCRETE TO MINIMUM PLAN`\ c e FPPIPEE BMI pt 5r �# gN 1 A ( / ° T E " v r RE cGCTInN Y-Y GIRD VIEW END SECTION DIMENSIONS PIPE DIAMETER A R L IT 4.. 2..0'. 2..0.' 4• 2..0- I g.. 2,5. r- . 4• -s- Ig• 9• 2.-3• 1"W. A'.M 3.,0, 2l' D '. T-11" 2'-1" 5'-0' 3'-B" 24.. 9 }.-2.. 2.-g.. g..l.. 4..0.. 27., p .. 4•-0. 2.. p. 8..1- 4..6. 50.. 1.-0.' 4.-e'. p_T g'_1 5._0. 33.. 1..1.. V-V .. 2.q .. T._ 5.-g. 36. 1._1- 5.-3.1 2.-p " g._ g.-0., 42' 1 5.-}. 2.11. g..2. A-B.. 4E.. 2.-0. g._0.. 2._2.. 1-2" p.0.. W. 2..3.. 5._5.. 279 .. g..2 .. T.-g.. -: 545 540 535 530 525 520 515 510 11 +00 ALTERNATE END -SECTION 12'' - 50" PIPE L= END NO W ON HALT EN D HER SECTpgli T1 j _ TO 4000 PR AIM M E d C I� PLAN �a�B ETER PPE J"`A X STEEL FIAVIC REIniORCEz.;,, 1 4 A I.- D E I- ver LNrs END VIEW SECTION X-X END SECTION DIMENSIONS PIPE D"AETER A B C 0 E R. 4. T 0.. 4,-T. gip" 7,OD 15• g• 2,}.. 3. X] 7..5. N, p. 3. 2. 2.. B.. g.-3.. 4.0.. 27 I1.0.� 4�.0. 2.. g.-Y x 4..g. 30. 4,.6 0,. W_ 1. i, g.-p. 99. 5..3.. .ql•.. B.-2. g._g.. 48. 2..0, g.-0.. 2..2., 1-2- 7-W' SP T 3 5'-5•' 2'-hF g'-4•• )._g•• - PAY LINE C_ a NOTES: PPE LENGTHS SHOWN ON BONS ARE NBASED T EIO-4LTbH DESIGN SHOWN ON ME LEFT. F THE CONTRACTOR ELECTS TO USE THE ALTERNATE DESIGN SAWN M1 THE RDM, EMAX Ns WILL BE RETRACED BY E DffERENLE N CYEN9IX1 '➢". I'IASTIt' NDLI TIM, 00 O11 12" C> 0 O0 00 000000 1- 6" (A) Bottom Rack Side Section DETAIL SHIMP ENGINEERING LAND PLANNING I SITE DESIGN I CIVIL ENGINEERING I PROJECT MANAGEMENT Design Focused Engineering 912 East High Street Phone: 434-227-5140 Charlottesville, VA 22902 skimp-engirleenng.mm VSMP PLAN ALBEMARLE COUNTY, VIRGINIA PROFFIT ROAD TOWNHOMES SOUTH SUBMISSION: 2020.03.20 REVISION: 1) 2020.07.16 2) 2021.03.30 3) 2021.06.07 FILE NO. DETAILS IA I -' ASPHALT PAVEMENT WIDENING ��'�� KFE"` FLARED END -SECTION FOR 1211-60'1 CONCRETE PIPE CULVERTS I ROAD AND aRDGE siaIDARDs I I "� SHEET 1 aF 1 REVMSKIN DATE FOR WIDENING SUBJECT TO TRAFFIC VIRGINIA DEPARTMENT OF TRANSPORTATDN Jg 302 VIRGINS DEPARTMENT OF TRANSPORTATION '0Z0l �.D2 SHEET C10 OF 12 r4_NWPHALT PAVEMENT WIDENING s ES-1 DETAIL '� 0 C10 NOT TO SCALE C10 NOT TO SCALE STORMWATER / 532 _ \ )34 - - _ _ _532- OFFSITE WOODS A-0 12AC \\ OFFSITE IMP. \ TOTAL PRES'DEV ` DA=3.68AC 30 5s / 5PO .02AC I I — 0 0 V 0 0 0 0 \7 7 0 0 0 0 0 P 0 o V A\ �� 0 1 0 V 0 0 0 V 0/ 0 V 17 0 V W---7 sy Do 0 V 0 0 OFFSITE TURF_ 528, _ �,� ,� -,1 �,� - - - - ��o '71Q o '7�Q ��e_ _ zZ N\ ,, > 526 - f 1 , \ N22'24'08' 4 W y \ NO -2 .58 — — I ' \ 456. .68V I ��� FOUND �-- \e I< 11 _ -_ lil lil lil III III III Ii� I I III <v I- L_—F I EICI III III III III III I I CALCULATIONS WATER QUANTITY POA ONSITE OFFSITE ACRES 3.15 0.53 CN 64 61 ONSITE Q1 = 1.20 CFS RV = 0.12 OFFSITE Q1 = 0.13 CFS NOTES 1. ALL SOILS 27B - ELIOAK LOAM - 2 TO 7% SLOPES, HSG B. WATER QUALITY 0.37 AC WOODS 2.72 AC TURF 0.25 AC IMPERV v ` ` III — — — — _ III III ` III \ LEGEND III �I ON -SITE IMPERVIOUS \ _ _ V A III III III 32 III III III ON -SITE MANAGED TURF v v v 1I I —III— III CI 0 \ \_ 1 II— ON-SITE WOODS v III III III E OFF -SITE IMPERVIOUS ElOFF -SITE MANAGED TURF ` III III III — III A ` OFF -SITE WOODS TREATED \ I I I ; v s32 III III III <, <I A III III —III — <ONSITE� WO6DS A=6.36A � o I v < < < < < <v `�� IIIIII sz 6 \ TOTAL ONSITE ` < < < ,� DA=3.15AC v� v < T6C=1$ MINUTES' < < MI z TIME OF < <v < < < < < < < v 522 < < < < ' < < < < < < v CD�IGE �TE� _sus < < < <,� < < < F I o < < < < < < 18.0 MIN _ < < �-- _ 52 N � 4 < < < ' < < < TOTAL OFFSITE < < < I _ — _ _ DA=0.53AC i I - 526 -�_ � --524 FI ON ,III T--0�18 MINUTES 526 I 1=1I JAI —III _ — - — - — < < I < III II I— III III I ----- — -- < < <_ ONSITE TURF � IIII—III— � F \ �____ — — — I � I1 I I III ----A �_2:48AC - _ 3 II II II —III— I ----- _ _ I I 0 — — — s — — _ _ _ IIII1III QN IT IMP. 11 I I— III III I I I� I I& I 530 SET 6`08'59"W ,9A=0.31 AC — — — I F / � 530 I E UND \ / 53 — — — \ 1 1 \ SHIMP ENGINEERING LAND PLANNING I SITE DESIGN I CIVIL ENGINEERING I PROJECT MANAGEMENT Design Focused Engineering 912 East High Street Phom: 43 227-51Q Charlottesville, VA 22902 skimp-engineering.mm VSMP PLAN ALBEMARLE COUNTY, VIRGINIA PROFFIT ROAD TOWNHOMES SOUTH SUBMISSION: 2020.03.20 REVISION: 1) 2020.07.16 2) 2021.03.30 3) 2021.06.07 532 — — �� 0 I I 1 ( I FILE NO. \ 18.041 i� 0 I\ \\ PRE -DEVELOPMENT DRAINAGE \ I \ 20 0 20 � � SHEET C11 OF 12 1160 � C 11 Scale: 1 "-20' �a TOTAL-OFFSITE TREAT ' --- A=0.32AC TOTAL ONSITE TREATED TOC=5'MIN TES (ASSUMED) 30 A=2.86AC TOC=5 MINUTES (ASSUMED) - POA-_( 1 52p- _ 5z6 TOTAL, UNTREATED � A=0.30AC TOCG5 MINUTES (ASSUMED) TOTAL DRAINAGE ARE =3.68A FSITEjTREATED TURF��\ - 5M mom now 70 I I I A C OFFSITE UNTREATED TURF A=0.21AC CON CEN TF -/ Lamm I I NNW I I TOTAL OFFSITE UNTREATED A=0.21AC TOC=18 MINUTES (CALCULATED) �- r S O mom ONSITE UNTREATED IMP.- - 532 -- -- A=0.003AC VIVJI I C UIV I mr—m I CU I umr A=0.29AC 1 / 532 I 530 -OFFSITE TREATED IMP. A=00..�02AC A=0.94AC `, s.G.FLQVV � I \ I STORMWATER CALCULATIONS WATER QUANTITY ONSITE OFFSITE TREATED UNTREATED TREATED UNTREATED AC 2.86 0.30 0.32 0.21 CN 86 61 61 61 POA 01 =0.40 CFS RV=0.415 AT NOTES 1. FLOW FOR POA ANALYZED AS IT LEAVES THE SITE RATHER THAN AT THE OUTLET OF STORM PIPE Al FOR EASE OF CALCULATION. NO ADDITIONAL WATER IS COLLECTED AFTER STORM INLET A4. 2. TIME OF CONCENTRATION FLOW PATHS NOT SHOWN. ALL ASSUMED 5 MINUTES. 4. ALL SOILS 27B - ELIOAK LOAM - 2 TO 7% SLOPES, HSG B. WATER QUALITY TREATED 1.25 AC TURF 1.94 AC IMP LEGEND ON -SITE IMPERVIOUS TREATED ON -SITE MANAGED TURF TREATED OFF -SITE IMPERVIOUS TREATED OFF -SITE MANAGED TURF TREATED OFF -SITE WOODS TREATED 1 ON -SITE IMPERVIOUS UNTREATED ON -SITE MANAGED TURF UNTREATED LJ OFF -SITE MANAGED TURF UNTREATED SHIMP ENGINEERING LAND PLANNING I SITE DESIGN I CIVIL ENGINEERING I PROJECT MANAGEMENT Design Focused Engineering 912 East High Street Phone: 434-227-514D Chatlottesville, VA 22902 shimp-engineetlng.com 15183 zf VSMP PLAN ALBEMARLE COUNTY, VIRGINIA PROFFIT ROAD TOWNHOMES SOUTH SUBMISSION: 2020.03.20 REVISION: 1) 2020.07.16 2) 2021.03.30 3) 2021.06.07 FILE NO. 18.041 POST -DEVELOPMENT DRAINAGE z 20 0 Scale: 1 "=20' Z SHEET C12 OF 12 C12 onxxMum im m 11 LEGEND DIMPERVIOUS El WOODS NOTE: ALL SOIL HAS HSG B SHIMP ENGINEERING LAND PLANNING I SITE DESIGN I CIVIL ENGINEERING I PROJECT MANAGEMENT Design Focused Engineering 912 East High Street Phom: 43 227-51Q Charlottesville, VA 22902 shimp-engineenng.wm VSMP PLAN ALBEMARLE COUNTY, VIRGINIA PROFFIT ROAD TOWNHOMES SOUTH SUBMISSION: 2020.03.20 REVISION: 1) 2020.07.16 2) 2021.03.30 3) 2021.06.07 FILE NO. 18.041 PRE-DEV. VRRM MAP SHEET C13 OF 14 C13 Scale: 1 "=20' \l LEGEND -- ON SITE IMPERVIOUS TREATED OFFSITE WOODS TREATED OFFSITE TURF TRATED OFFSITE IMPERVIOUS TREATED NOTE: ALL SOIL HAS HSG B SHIMP ENGINEERING LAND PLANNING I SITE DESIGN I CIVIL ENGINEERING I PROJECT MANAGEMENT Design Focused Engineering 912 East High Street Phone: 434-227-5140 Chadottesville, VA 22902 shinnp�engineenng.com VSMP PLAN ALBEMARLE COUNTY, VIRGINIA PROFFIT ROAD TOWNHOMES SOUTH SUBMISSION: 2020.03.20 REVISION: 1) 2020.07.16 2) 2021.03.30 3) 2021.06.07 FILE NO. 18.041 POST-DEV. VRRM MAP SHEET C14 OF 14 C14 Scale: 1 "=20' Section 6. Pollution Prevention Plan. (reference County Code 17-404 and State Regulation 9VAC25-880-70 part II section A.4) A. Plan showing pollution activities and prevention practices (Provide a reduced I Ix17 copy of a site plan on which all of the following activity locations are clearly marked. Keep this plan up-to-date with ongoing site changes and inspections.) Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County V A NEW 30' V �� / � 1 c �5 „U 526 - / \\ \V \ \\ \ �526, \V OA � / BOLLARDS RON �\ IMITS F ISTU A CE N22'24'O8"E 48268' w \ FO ND 2 .58 IRON Dense Trees FOUND \ \ -- 32 4 34 0 / F.<OPOSEDV R05 7 \ p A4D 1 - \\ 1 Z o CA 2 8 3 eoev 1 / i 1 qj EMERGENCY ENTRAN6E 3 ---- DEDICATION .5� WIDTH- ` 1 4 i� - -� - - - - - - - - - - - _ _31 I I ■ ° 1 ■ FROM ROAD CL _ 1 2750 FEE0528.00 °° \ L �,\ \ \ 1 „ I 1 ONE CAR 28 1.5 \ I 1 8 0 REAR SETBACK \ x so so / I \ I / GARAGE UNIT �) - $ 1 _ so \ �0 31 �, / NEW 20_ACSA_ I<. 28 22 299 30 3 I / _ �„�`o- - EASEMENT 4 Q Al 1 0\ EX. 8" DI SAN 1 o LOT 30 5 8 V A V A I V A 32 \ c\ FEE 527.50 Sz4\ - 2� -01VE -CAR 2750 1.00% 127R8 2 a fi \ \ \ I I LOT 37 LOT 38 L0� 39 LOT 40 GARAGE UNIT _ "'-_ $ LOT 32 LOT 33 LOT 34 \LOT 35 LOT 36 \ I FFE 531.50 FFE 532.00 FEE 132.50 FEE 533.00 OPEN 0< 9 F�� 529.00 FFE 529.50 FFE 530.00 FF 530.50 FFE 531.00 \ ONE CAR ONE CAR ONN6 CAR ONE CAR I \ SPACE P,4 \- �. \ I 1 ONCE CAR ONE CAR ONE CAR 0 E CAR ONE CAR - I GARAGE UNIT GARAGE UNIT GARAGE UNIT GARAGE UNI _ 3,790SF \ 2 L STE / 2 \ \ CD X _ \ 1 y I 1 GARAG'E� \IT GARAGE UNIT ARAGE UNIT GARAGE UNIT GARAGE UNIT \ I I I "NO PARKING' ) SLEE E / 27'° LOT 29 I - � \ � I 1 \ \ / - O - , � l ■ 1 FFE 527.50 0 I 6 a o \ _ ONE CAR 275 3.3 x 6 \ \ \ / - --- 2 BOLLARDS \ ■. \ \ 1 GARAGE UNIT ° I MA 25' ETBA K 0° 00� z _. - o __ \ ° m w w 30 31 o[n i c "E \ 28 \ 0 29 soA 30 J - �GMh I I W \ _ \ 28' 29 o AS 2 TO EXISTI G I / 0 1 I N I \ b I WATERLI E -,- 2eo LOT 28 0 .. o 1 I I I a I\ I I °> /I ro rn / m-A x31- \ FFE 527.00 I \ _ n n 1 - I o ONE CAR 2� 2.19% 26 2 \I \ �1 'i �� (6 �� / -1 D / l I \s� = GARAGE UNIT I _ $ I v 1 \ n 2 51,„ \ D I MIN. 5 E BA K I`oa 10 iX \ _ -2 z °z - - -° "NO PARKING" �Q 1 p ,5'.COSID WALK.2T ° °EW 30''.ACSA IS g3'_ _.° .az v= m LOT 27 X6%�;/� WALK ( \ \ I 1 2\ FFE 527.00 0 m 0 s0 I C/ - �ee z { _ - - C - ao�., I \ ONE CAR 2� 3.68 126' S ° I x4" �„ �� �� S x� �6 OV -,GARAGE UNIT I o 3tEx \ 2 2 CG- �_9 2 \ / "NO PARKNG" � A90° \ - NEW V R ABLE TH \ - \ -- W W �I �Wn8' WV WIW W yJW ■ _ _ _ TAW \ NEW 20' PRIVATE ■ __ A4B\ ., �8° "M ANA EM ENT ES yy �.. Twimm■ 2 A4A EE` - - - - 1.84%.. 2 TE \ I \ 8" D 6., E 8' DI DI L0 1 0 \ 1 v X. 5 ➢➢Z : "X6°RED _'\'\ \ PRIVATE R0.5,3c, A 2' D- EAR AG SUNIT i \ - s, RED, A5 / TY so 1 G n v \ \ HDPE STORM 5 56� HP S - - \ - - - DI-3 - - S s \ 3 (9 p0% 34 I \ w \ \ \ ■ 1` 0 ca - W „ 0. - . a i 4-9r 1z0 \ O / V A TURBA E ? A3 WEIR WALLS LO G SWE V N_EVy 3 •,\ ` T ° NE�' - 3 X M L VERLA cn 4� C ` ---- -- -- hfe \�- ---- s --� - WM ws3 1 z GI Srn \ \ _ _ x .�. . n._ $" WS 25 P 2 o J22- + ao S \ - - - - LOT v! A E C 12 > 1- "' �� F 53 .00 G) o I \ x o N so LOT 22 TYE Ca `< / 1 So b\ S 1-S 34 GAR GE NIT \ c 1 I 1 26 FFE 527.00 o I . ,e e .e y \ .8 A� e 9. o A7 .a o v 32 0 0.93 0 ('� - GARAGE UNIT ONE CAR 2% 4.32% 26 5 m \ a g x 6 �1 aN-1 MAKE m r MAT} 1 0 � aa1( Y4 70% 70o LOT 16 \ 7+'° aACKFL��/ �REVENTEf� FFE \ .-->�; yy > i 1 CAR TWO CAR � = I GARAGE UNIT \ 6" so LOT 23 26 8. UNDERDRAI� -/ FFE 527.00 0 _ -� 5s s os ONE CAR 2% 3.10% 26 2 5 l GARAGE UNIT z Q'36 1 I R1 4,057 oo 7 LOT 17 26 7 _ 1 FFE 528.00.i. `i TWO CAR : uh \ 1 o al GARAGE UNIT \ O'l°' _ _ 265° LOT 24 FFE 527.00 "� .o \ / ONE CAR � E? 2 2 .�7 2750 FFE0528 50 2m 753 .4 X /8" WMH n TWO CAR n (Ti P.) L z x GARAGE UNIT �- Igg / o LOT 25 2% i N = FFE 527.50 ONE CAR 2o 75 3.76% I ' , 26'- , 2 o, 6 r-� N v GARAGE UNIT - $ § m v, / cc 28 19 y 058 a 7vs / .90% FEE 2 50 m _T D x27 I TWO CAR / _ - g 4 I I GARAGE UNIT / N / o LOT 26 2� FIFE527.50 1 CARD 2750 2 53 z 632 - GARAGE UNIT . $J b I /°ot 4 1 3.86% ��11 50 / / ,. x ea 7 A4 -FFE0528 TWO-6AR- NE -LJ/p, GARAGE UNIT N F 532- 00 GANIT ~S J vm \ n \ L0 5 4.51T \ \Iy I I \ 11 \ 86 I 33 GAR` m \ L07 10 S `o FFE2.50 I \ 32 \\GARAGE UNIT 1- s0 S I 50 FFE 534 \ as 31 S 3�5% 33 GARAGE NIT EV ■ `.. \ CD o 22 0 \ OR�€SM y -� \ � r \ ■ w \ A B o \ LO 0 S M 1 c� pSEE TION QPy 1 -- 32 GARAGE\UN �`e`P•` eo / _ T 1 e I .32 s sA � ■ s 5 15" HP STORM \ 1 � o I ■ � n \ 32503� L i NO PARK .I \ N 00 1"0 532.50 � � S �- 32 31 e 211z : A. GARAGE UNIT - ws No �-o / - _ \ ■ v, 1l1 T.I / oo FFE 534.0 f` ■ I \ I I SHIMP ENGINEERING v �32 5.56% 1 S / 'QQ% X � \ \ LAND PLANNING SITE DESIGN CIVIL ENGINEERING PROJECT MANAGEMENT HH y� � c . T 13 /D -� �-1- Z 1 5�$ W N �,- 1 ■ I \ I Design Focused Engineering v 3 2 FFE N 532.50 �S I (TYP.) I \I I ■ ui I \ - 31 1 UNIT / y O GARAGE / GT 6 I o I I Chadotlemile, VA 22902 skimp-engineenng.mm a.Q S � L0533.5 y I � I ° S % 32 FEE 912 East High Street Phone: 43 227-51Q GE UNIT RA 50 LOT 14 6 ,S 9 x N -, c ■ �1 I o I ■ 1 1 $ X27ss 75s - 1 FFE 532�NIT I LOT 21 a 30 1 GARAGE _ LOT 7 - - - - 5�76 - -�i _ � 5.23% 28 FFE 528.5 I � Dense Tree \ I - TWO CAR 25 FFE GE3 NIT I , v 1 524 � IRON - I 7,0 �. 70 ' � GARAG � � . ge3 S �S TYP•i c - FOUND 1 - - 3150 5.96% '0 g.57 GARA ■ 1 - - -- -- -- --- <' - - J / A5 -6 30 I Iw I ■ 1 Ci L� N LOT BOA o s, FFE 531UNIT S 3 �o IW o p0 = c g\' 1 Lie: bl `5183 _ - - -- -- -- - - - - - - - - -528 LIMIT$- �F �l� .28x .GARAGE 9 \2b7 7URBANCE - - 2 b - 32 FFE 5 3UNIT o ■ I I '�i9 _ A9A1 5a a i� GA c ■ / - 528 - 28 2 I I '�St®NAl ND NONEXCLUSIVE RIGHT p _ _ 15 0 % 530 - ---A_10 ND (D.B.� 615) - - - - - - - - � - a I / 4 69 = ■ 530 IRO 7:�lSET S26°08'59"W 169.50' I \I ■ 1 GL-- - CA _ - 1 c _ IRO VSMP PLAN FOUND g \\ ALBEMARLE COUNTY, VIRGINIA ���� ► I _ _ - - - - - - - 532 PROFFIT ROAD TOWNHOMES A2 F DR - \ S,s 26 SAN ■- ■ MATCH L � � d� 1 SOUTH I \ I o ■ NEW 20' 24" / 0 1 \ SUBMISSION: °MINI ■■�■ MANAGEMENTESmf' HDIRE STORM 2020.03.20 ■ r \ CN REVISION: 1 I LIMI TS OFU�URBq \ I 2) 2021.03.30 W 1 3) 2021.06.07 I O \\ �4t' I/� • s� I I 11 1 LIMITS OF vV A I I TMP 32-29D DISTURBANCE Mi GROVE CHRISTIAN 1 CHURCH AREA = 3.34 \ 1 AC \ I 1 \ \ \ \ I FILE NO. \v) J / \\ \\� \ 18.041 0011 LASS A Rl�-RAd i i vv v GRADING & UTILITY PLAN SHEET C4 OF 12 20 0 20 40 60 Scale:1"=20' �II Pollution Prevention Plan Prevention - Stopping - Containing - Cleanup - Reporting A spill is reportable if it; causes a sheen (the sheen rule), creates discoloration/emulsion on surface waters, or reaches storm drains. Any Fish Kills must be repo d. Reporting information regarding specific substances can be found below. Potential Pollution Generating Prevention/Response Activities: QuickReference Chart Fuels, Hydraulic Vehicle refueling and maintenance operations will be conducted in a dedicated Oils and Vehicle location away from surface waters. Secondary containment (berms), readily Maintenance available spill kits and cover will be provided where appropriate. For additional information, see the Fuels and Oils subsection below. Soaps, Solvents, Chemicals will be safely stored in sealed containers when not in use. Clean-up and Detergents & disposal will be done in a manner to prevent contact with stormwater, utilizing Wash Water cover, tarps, buckets, and proper disposal techniques. For additional information, see the Hazardous and Toxic Chemicals subsection below. Construction products and materials will be stored in a safe location and handled in a manner consistent with the pollution prevention plan and manufacturer's Hazardous recommendations. Likely utilized items on site include asphalt sealants, copper Materials Construction flashing, roofing materials, adhesives, concrete admixtures, pesticides, herbicides, products, materials, insecticides, fertilizers, and landscape materials. Construction and domestic wastes and wastes such as packaging materials, scrap construction materials, masonry products, timber, pipe and electrical cuttings, plastics, Styrofoam, concrete, and other trash or building materials will be disposed of properly. For additional information, see the Hazardous and Toxic Chemicals subsection below. Fertilizers will be applied per manufacturer's recommendations and not during Fertilizers rainfall events. For additional information, see the Hazardous and Toxic Chemicals subsection below. On site portable lavatories must be located away from surface waters and storm Sanitary Wastes drains. Any spills must be cleaned according to federal, state and local regulations. For additional information, see the Sanitary Waste subsection below. Wash Water without Wash water will be directed to sediment basins or traps, using filtration devices Non-Stormwater Soaps such as filter bags or sand filters or similarly effective controls. Discharges Site Excavation Must pass through a sediment trapping device and be released onto a stabilized (Examples listed in Dewatering surface. Conveyance channels must be stabilized. Table 4 below) Utility Flushing Energy from clean water releases must be appropriately dissipated in a stabilized area. For additional information, see the Water Testing subsection below. Concrete wash water will be directed into a leak -proof settling basin or container. The container or basin shall be designed so that no overflows can occur due to Concrete Waste & inadequate sizing or precipitation. Hardened concrete wastes shall be removed and Wash Water disposed of in a manner consistent with the handling of other construction wastes. Liquid concrete wastes shall be removed and disposed of in a manner consistent with the handling of other construction wash waters and shall not be discharged to Managing Waste surface waters. For additional information, see the Concrete subsection below. All solid waste and debris must be deposited in dumpsters and kept out of surface waters. Exposure of waste materials to precipitation shall be minimized by closing Solid Waste or covering waste containers during precipitation events and at the end of the business day or by implementing other similarly effective practices. Minimization of exposure is not required in cases where the exposure to precipitation will not result in a discharge of pollutants. Other Spills and Leaks Oil, chemical or other hazardous substance spills and leaks that exceed the reportable threshold will be reported to the DEQ in accordance with Part III G of the Permit as soon as the discharge is discovered, and in no case later than within 24 hours. A reportable quantity of oil is defined by the EPA as a discharge to surface waters that causes a sheen, discoloration, and/or an emulsion. A written report of the unauthorized discharge shall be submitted to the DEQ and VSMP authority within five days of the discovery of the discharge and include the information listed below: • Name, address, and telephone number of the person reporting and the responsible party • Specific location of the incident • Date and time the incident occurred or was discovered • Name of the chemical/material released • Source and cause of the release • Total quantity discharged • Medium into which the substance was discharged • Amount spilled into water • Weather conditions • Name of the carrier or vessel, the railcar/truck number, or other identifying information • Number and type of injuries or fatalities • Whether an evacuation has occurred • Estimation of the dollar amount of property damage • Description of current and future cleanup actions • Other agencies notified or about to be notified Reports will be made to the following: DEQ Valley Regional Office Phone: (540) 574-7800 Fax: (540) 574-7878 For reports outside normal working hours, leave a message. Virginia Department of Emergency Management Emergency Operations Center (EOC) Phone: 1-(800) 468-8892 Materials and equipment necessary for oil or chemical spill/ leak cleanup will be kept in the temporary material storage trailer onsite. Equipment will include, but not be limited to, brooms, dust pans, mops, rags, gloves, goggles, universal absorbents, sand, saw dust, and plastic and metal trash containers. All oil or other chemical spills/ leaks will be stopped, contained, and cleaned up immediately upon discovery. Those large enough to reach the stone sewers will be reported to the National Response Center at 1-800-424-8802. In the event of a hazardous spill contact: 9-1-1 Fuels and Oils The State Code of Virginia §62.1-44.34:19, states that discharges that may be reasonably expected to enter state waters, lands or storm drains must be reported. In the event of a spill, it will be stopped, contained, and cleaned up immediately and the material, including any contaminated soil, will be disposed of according to all federal, state, and local regulations. Any on -site storage tanks will have a means of secondary containment. All vehicles on site will be monitored for leaks and receive regular preventive maintenance to reduce the chance of leakage. Petroleum products will be stored in labeled, sealed containers. Spill kits will be included with all fueling sources and maintenance activities Hazardous and Toxic Chemicals Spills of hazardous or toxic chemicals that exceed the reportable quantity threshold must be reported, as previously stated. The EPA lists reportable quantity thresholds for each chemical under 40 CFR Part 110, 40 CFR part 117, or 40 CFR part 302. All paint containers and curing compounds will be tightly sealed and stored when not required for use. Excess paint will not be discharged to the storm sewers but will be properly disposed according to the manufacturer's instructions. Spray guns will be cleaned on a removable tarp. Chemicals used on -site are kept in small quantities and stored in closed containers undercover and kept out of direct contact with stormwater. As with fuels and oils, any inadvertent spills will be cleaned up immediately and disposed of according to federal, state, and local regulations. Fertilizers will be applied only in the minimum amounts recommended by the manufacturer. Fertilizers will be worked into the soil to limit exposure to stormwater. Fertilizers will be stored under cover and partially used bags will be transferred to a sealable bin to avoid spills. Sanitary Waste Portable lavatories are located on -site and are serviced on a regular basis by a contractor. They will be located in upland areas away from direct contact with surface waters. Any spills occurring during servicing will be cleaned up immediately, including any contaminated soils, and disposed of according to all federal, state, and local regulations. Concrete Concrete trucks will not be allowed to wash out or discharge surplus concrete or drum wash water on the site, except in a specially designated concrete washout area which contains all wash water resulting from washout activities. Form release oil used for decorative stonework will be applied over a pallet covered with an absorbent material to collect excess fluid. The absorbent material will be replaced and disposed of properly when saturated. Water Testing When testing/cleaning of water supply lines, the discharge from the tested pipe will be collected and conveyed to a completed stormwater pipe system for ultimate discharge into a sedimentation basin or SWM/BMP facility. Authorized Non-Stormwater Discharges The following table (Table 4) displays non-stormwater discharges from construction activities that are authorized by this general permit when discharged in compliance with the permit: Table 4. Authorized Non-Stormwater Discharges A Discharges from firefighting activities and/or fire hydrant flushings. B Waters used to wash vehicles or equipment. r C Landscape irrigation, or water used to control dust. D Uncontaminated waterline flushings, air conditioning/compressor condensate, and ground or spring E Potable water sources, including uncontaminated waterline flushings. F Routine external building wash down. I G Pavement wash waters where spills or leaks of toxic or hazardous materials have not occurred (or where all spilled or leaked material has been removed prior to washing). r H Foundation or footing drains where flows are not contaminated with process materials such as solvents. I Uncontaminated excavation dewatering, including dewatering of trenches and excavations. Where soaps, solvents, or detergents have not been used; and where the wash water has been filtered, settled, or similarly treated prior to discharge. B. Sources of Pollutants, locations, and prevention practices Pollutant, or Pollutant Location on site Prevention Practices, Generating Activity Control Measures C. Sources of Pollutants, continued. Common activities and minimum control and prevention ractices Pollutant, or Pollutant Location on site Prevention Practices, Generating Activity Control Measures Follow Erosion and Sediment Control Clearing, grading, excavating, and on- Land disturbance area Plan. Dispose of clearing debris at stabilized areas acceptable disposal sites. Seed and mulch, or sod within 7 da s of land clearing Cover stomr drain inlets and use drip Paving operations Roads and driveways pans and absorbentloil dry for all paving machines to limit leaks and spills Direct concrete wash water into a leak - Concrete washout Current location and detail shown proof container or leak -proof settling and cement waste on plan basin that is designed so that no overflows can occur Enclose or cover material storage areas. Mix paint indoors in a containment area or Structure construction, stucco, Structures in a flat unpaved area. Prevent the painting, and cleaning discharge of soaps, solvents, detergents and wash water, paint, form release oils and curing compounds. Water shall be filtered, settled or similarly Dewatering operations Dewatering sites shown on plan treated prior to discharge as shown on plan. Designated areas for material delivery Material delivery and storage Designated area shown on plan and storage. Placed near construction entrances, away from waterways and drainage paths Material use during building process Building areas Follow manufacturer's instructions . MSDS's attached, waste collection area will not receive a substantial amount of runoff from upland Solid waste disposal Current designated container areas areas and does not drain directly to a on plan waterway. Containers have lids covered before periods of rain, or are in a covered area. Scheduled collection to prevent Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Pollutant, or Pollutant Location on site Prevention Practices, Generating Activity Control Measures overfilling. MATERIALS NOT TO BE BURIED ON -SITE Convenient and well -maintained portable sanitary facilities will be Sanitary waste Current locations shown on plan provided, and located away from waterways or inlets. Such facilities shall be regularly maintained. Apply fertilizers in accordance with Landscaping operations Landscape areas shown on plan manufacturer's recommendations and not during rainfall events To be treated in a sediment basin or Wash Waters Wash areas shown on plan better control as specified on plan. Minimize the discharge of pollutants from equipment and vehicle washing Vehicle and equipment washing Designated areas and details shown on Provide containment and filtering for all plan wash waters per the plan Minimization of exposure to precipitation and stormwater. Minimize the exposure of building materials, building products, construction wastes, trash, landscape materials, fertilizers, pesticides, herbicides, detergents, sanitary waste, and other materials present on the site to precipitation and to stormwater. (Identify all non-stormwater discharges to occur on your site. Keep this plan up-to-date with ongoing site changes and inspections. See CGP, 9VAC25-880-70 section E for examples of non-stormwater discharges.) I13 Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County E. Persons responsible for pollution prevention practices (Provide the names and contact information for all persons responsible for prevention practices as listed above.' F. Response and reporting practices Minimi=e discharges from spills and leaks. Minimize the discharge of pollutants from spills and leaks and implement chemical spill and leak prevention and response procedures as follows. Respond to all spills, leaks and discharges as follows, Report all spills, leaks and discharges as follows, (Provide detailed response and reporting practices according to 9VAC25-880-70, Part II, section A.4.e.) G. Pollution Prevention Awareness (Describe training and procedures to provide awareness and compliance for all measures in this document; waste management, wash waters, prevention measures, etc.) Issued — 10/2014 Stormwater Pollution Prevention Plan (S WPPP) Albemarle County Section 7. Discharges to impaired waters, surface waters within an applicable TMDL wasteload allocation, and exceptional waters. (Provide detailed measures for any applicable TMDL) Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Fact Sheets, for Impaired (Category 4 or 5) Waters in 2020 James River Basin Cause Group Code: H26R-05-BEN Powell Creek Cause Location: Powell Creek (including all tributaries) from the headwaters downstream to its confluence with the South Fork Rivanna River. (Start Mile: 10.36 End Mile: 0.00 Total Impaired Size: 10.36 Miles) City / County: Albemarle Co. Use(s): Aquatic Life Cause(s) / VA Category: Benthic Macroinvertebrates Bioassessments / 5A This segment is impaired due to exceedances of the General Standard for Benthics at station: 2-PLC001.49 (Impaired for VSCI), 2-PLC-PWL01-RCA (Impaired for VSCI) and 2-PWC-PWL03-RCA (Impaired for VSCI). Initial Listing Date; 2010 Cycle TMDL Cause First Dev. Water Assessment Unit / Water Name / Location Desc. Category Cause Name Listed Priority Size VAV-H26R_PLC01A10 / Powell Creek / Powell Creek and 5A Benthic Macroinvertebrates 2010 H 10.36 tributaries from the headwaters downstream to its confluence with the Bioassessments South Fork Rivanna River. Powell Creek Estuary Reservoir River Aquatic Life (Sq. Miles) (Acres) (Miles) Benthic Macroinvertebrates Bioassessments - Total Impaired Size by Water Type: 10.36 Sources: Non -Point Source Final 2020 Appendix 5 - 993 0 Project Area: ±3.3 acres VPDES Registration Site Map - LOD Proffit Road Townhomes Stream WSSI #32316.01 NORTH 0 Waterbody cE Primary Construction Entrance Latitude of Primary CE 38.131363' Longitude of Primary CE:-78.431896' HUC12 Name: Jacobs Run -North Fork Rivanna River; South Fork Data Source: Albemarle County Digital Data Image Source: NearmapG - July 2022 'Area is based on GIS data, and does not reflect the legal acreages of the site. For exact LOD acreage, see approved plans. 0 200 Feet Onginal Scale: t "= 200' Wetland Studies and Solutions, Inc. a DAVEY1. company Exhibit 1 "'a a°d cu,A D. 01! °vM Oi Do a.Ig4^ d � Y°^� a IF va 3• CYp�e O ua� V6�44 ! �OnFflEe p•� aCe d C g °y a apO nRtl d 9 nrpon � o r°rn! v` r NavSpn P �•4 m°•ne 0 Albemarle County VA Q Project Area Cv RAv� celmru ce u9 P e e d ta' Tl' E vDeceA°v a ip •i�nbe�p 'T ^" Rc„rv' w vm 8 oe ^•lgtl rang .° cR'^n�al o� � Ps D ° 0 0, ,l FyetlielP Di C°ja P 1A� N011vm P � s 5 e a R°pin In r'd pP1 1 3tl pe peitlV !° In 3 P° sPa 117, SVen4°leRp p3 R`�~\ 0.aa� P°wtll c-. D. it n poes sn °tA rl 3ooyp J psM1w°°oBs Vicinity Map Proffit Road Townhomes WSSI #32316.01 Source: World Street Map - ESRI Wetland Studies and Solutions, Inc. a DAVEYI company NORTH 0 2,000 Feet Original Scale 1"=2MO Exhibit 2 lJv`_ Q Project Area USGS 7.5' Quadrangle Map Proffit Road Townhomes WSSI #32316.01 Earlysville, VA 1984 Latitude: 38'7'51"N (38.130833') Longitude: 78°25'54"W (-78.431666°) Hydrologic Unit Code (HUC): 020802040303; 020802040203 HUC12 Name: Jacobs Run -North Fork Rivanna River; South Fork Rivanna River COE Region: Eastern Mountains and Piedmont i rJ�rr1 �la�`. NORTH 0 2000 Feet Onginal Scale: 1 "= 2,000' Wetland Studies and Solutions, Inc. Exhibit 3 a DAVEYI company L\32000S1ZJUUW231b,U1\ 1SWFUEb SWYYY\3231b,U1 U4 NW1mXd R4SBC PUBHh o' R4SBC ° m N Pa PVRHh= a R4SBC a_ RVRHir % < r'OOrt.RuRSVBH ^ �/ a f d R4SBC „ R4SBC r°i RSUB R45BC 4g c 5zF Proffil-Rd PVmh P'F01A 9 R RSV H JJ PEM11!h PVBEix PUBX � V I 3 n^ "` R4SBC R45 BC 0 � � G g PVB4 I�I \ PVBHh `�RSUBH \R4 I Q� � n //' 3 PVBHh ° 5BC R4SBC RSVBH , u RSVBH ll/ RSl93H R45 BCt PF01A R5VBH �PS41Ch R45'BC ">'i 0 Project Area Wetland Type 0 Open Water - Freshwater Forested/Shrub Wetland Freshwater Emergent Wetland 0 Estuarine and Marine Welland 0 Other Digital National Wetlands Inventory Map Proffit Road Townhomes WSSI #32316.01 Source: U.S. Fish and Wildlife Service; December 2021 NORTH 000 Feet Original Scale: 1 "= 1,000' Wetland Studies and Solutions, Inc. Exhibit 4 a DAVEYI company Section 8. Qualified personnel The following personnel are responsible for inspections; (Provide the name, telephone number, and qualifications of the qualified personnel conducting inspections.) Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County COMMONWEALTH OF VIRGINIA State Water Control Board I I I I East Main Street, Richmond, Virginia 23219 DUAL Combined Administrator Caroline Marie Hollandsworth CERTIFICATE NUMBER DCA0457 EXPIRATION DATE 12/3/2022 mw DW VIHGINL-\ DI`R\HT\IENr OF ENVIRO\11E.\T\I. QUALITY This certificate is for your records and should be kept in a safe location. Please detach the above certificate and the two wallet size cards below. It is your responsibility to ensure that your certification is kept current and that you meet the requirements for re -certification before the expiration date. COMMONWEALTH OF VIRGINIA State Water Control Board I I I I East Maio Street, Richmond, Virginia 23219 DUAL Combined Administrator Caroline Marie Hollandsworth Certificate Number Expiration Date DCA0457 (D 12/3/2022 COMMONWEALTH OF VERGINIA State Water Control Board 11 I 1 East Main Street, Richmond, Virginia 23219 DUAL Combined Administrator Caroline Marie Hollandsworth Certificate Number Expiration Date DCA0457 12/3/2022 COMMONWEALTH OF VIRGINIA State Water Control Board I I I I East Main Street, Richmond, Virginia 23219 EROSION AND SEDIMENT CONTROL Combined Administrator Robert Rae Allen CERTIFICATE NUMBER ESCA0406 EXPIRATION DATE 3/6/2023 ow DW VIRGINL\ UI`R\RT\IENr OF ENvlRO\11E.\T\I. QUALITY This certificate is for your records and should be kept in a safe location. Please detach the above certificate and the two wallet size cards below. It is your responsibility to ensure that your certification is kept current and that you meet the requirements for re -certification before the expiration date. COMMONWEALTH OF VIRGINIA State Water Control Board I I I I East Main Street, Richmond, Virginia 23219 EROSION AND SEDIMENT CONTROL Combined Administrator Robert Rae Allen Certificate Number Expiration Date ESCA0406 (D 3/6/2023 COMMONWEALTH OF VERGINIA State Water Control Board 11 I 1 East Main Street, Richmond, Virginia 23219 EROSION AND SEDIMENT CONTROL Combined Administrator Robert Rae Allen Certificate Number Q„ % Expiration Date ESCA0406 .u� 3/6/2023 Email: rallen@wetlands.com Phone: 804-664-0295 COMMONWEALTH OF VIRGINIA State Water Control Board 11 I 1 East Main Street, Richmond, Virginia 23219 Dual Combined Administrator Landry Horner CERTIFICATE NUMBER DCA0551 EXPIRATION DATE 11/17/2024 DEO VIRGINU\ DEPARTMENT OF ENVIRO\:\IENT.\1, QUALITY This certificate is for your records and should be kept in a safe location. Please detach the above certificate and the two wallet size cards below. It is your responsibility to ensure that your certification is kept current and that you meet the requirements for re -certification before the expiration date. COMMONWEALTH OF VIRGINIA State Water Control Board I I I I East Main street, Richmond, Virginia 23219 Dual Combined Administrator Landry Homer Certificate Number Expiration Date DCA0551 on (D 11/17/2024 COMMONWEALTH OF VIRGINIA State Water Control Board 1 I I 1 East Main Street, Richmond, V irgwa 23219 Dual Combined Administrator Landry Horner Certificate Number Expiration Date DCA0551 11/17/2024 COMMONWEALTH OF VIRGINIA State Water Control Board 1111 East Main Street, Richmond, Virginia 23219 DUAL Combined Administrator Amanda Ward CERTIFICATE NUMBER DCA0470 EXPIRATION DATE 2/14/2023 mw Da) VIR iim,\ DI`R\RT\IENr OF ENVIR0\11E.\T\I. QUALITY This certificate is for your records and should be kept in a safe location. Please detach the above certificate and the two wallet size cards below. It is your responsibility to ensure that your certification is kept current and that you meet the requirements for re -certification before the expiration date. COMMONWEALTH OF VERGINIA State Water Control Board I I I I East Main Street, Richmond, Virginia 23219 DUAL Combined Administrator Amanda Ward Certificate Number Expiration Date DCA0470 Q) 2/14/2023 COMMONWEALTH OF VHtGINIA State Water Control Board I I I I East Maio Street, Richmond, Virginia 23219 DUAL Combined Administrator Amanda Ward Certificate Number Q„ ' Expiration Date DCA0470��"���' 2/14/2023 Wetland Studies and Solutions, Inc. Qualified E&S and SW Inspectors updated:O4/20/2022 VA DEQ E&5 Certifications VA DEQ STORMWATER Certifications DOT E&S Certifications National Cents. WSSI Office/Depart. RLD I Program Admin. I Inspector I Plan Review I Certifiration# Program Admin. I Inspector I Plan Review I Certification# NCDOT VDOT CESSWI CPESC Bryce Miller RVA-Compliance X X X DCA0329 X X X DCA0329 X X X X Caroline Roilandrwnrth RVA-Compliance X X X DCA0457 X X X DCA0457 X X X TBS Amanda Ward RVA-Compliance X X X X DCA0470 X X X DCA0470 X X TBS Bobby Rae Allen RVA-Compliance X X X X ESCA0406 X X X Provisional X TBS TBS Landry Horner RVA-Compliance X X X X DC40551 X X X DCA0551 X TBS TBS TBS=To Be Scheduled Nate 1- DEQ Combined Administrators have all three US or Stormwater Certifications Nate 2 - DEQ Dual Combined Administrators have all six E&S and Stormwater Certifications Section 9. Signed Certification (Provide certification according to 4VAC25-870-370) CERTIFICATION "i certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. l am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations." Operator Name: Scott Carlson Company: Greenwood Homes Charlottesville, LLC Title: Partner Signature: Date: - ��2 I /Z 7-- Issued— 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Section 10. Delegation of authority. (Provide the persons or po.a; io h, 11 • . I,"hy to sign inspection reports or to modify the stormwater pollution prevention plan. A formal, signed delegation of authority is needed.) Delegation of Authority I, Scott Carlson (name), hereby designate the person or specifically described position below to be a duly authorized representative for the purpose of overseeing compliance with environmental requirements, including the Construction General Permit, at the Profft Road Townhomes South construction site. The designee is authorized to sign any reports, stormwater pollution prevention plans and all other documents required by the permit. Qualified Inspectors (name of person or position) Wedand Studies and Solutions, Inc. (Company) 1620 Brook Road (address) Richmond, Virginia 23220 (city, state, zip) 757477-3904 (phone) By signing this authorization, I confirm that I meet the requirements to make such a designation as set forth in the Construction General Permit (CGP), and that the designee above meets the definition of a "duly authorized representative". Operator Name: Scott Carlson Company: Greenwood Homes Charlottesville, LLC. Title: ���� nX+:L Signature: Date: �� Z 4 / L ?� Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Section 11. General permit copy (Provide a copy of the construction general permit, 9VAC25-880) Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County COMMONWEALTH of VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY General Permit No.: VAR10 Effective Date: July 1, 2019 Expiration Date: June 30, 2024 GENERAL VPDES PERMIT FOR DISCHARGES OF STORMWATER FROM CONSTRUCTION ACTIVITIES AUTHORIZATION TO DISCHARGE UNDER THE VIRGINIA STORMWATER MANAGEMENT PROGRAM AND THE VIRGINIA STORMWATER MANAGEMENT ACT In compliance with the provisions of the Clean Water Act, as amended, and pursuant to the Virginia Stormwater Management Act and regulations adopted pursuant thereto, operators of construction activities are authorized to discharge to surface waters within the boundaries of the Commonwealth of Virginia, except those specifically named in State Water Control Board regulations that prohibit such discharges. The authorized discharge shall be in accordance with the registration statement filed with the Department of Environmental Quality, this cover page, Part I - Discharge Authorization and Special Conditions, Part II - Stormwater Pollution Prevention Plan, and Part III - Conditions Applicable to All VPDES Permits as set forth in this general permit. Construction General Permit Effective July 1, 2019 Page 2 of 26 FOWTO 1 DISCHARGE AUTHORIZATION AND SPECIAL CONDITIONS A. Coverage under this general permit. During the period beginning with the date of coverage under this general permit and lasting until the general permit's expiration date, the operator is authorized to discharge stormwater from construction activities. This general permit also authorizes stormwater discharges from support activities (e.g., concrete or asphalt batch plants, equipment staging yards, material storage areas, excavated material disposal areas, borrow areas) located on -site or off -site provided that: a. The support activity is directly related to the construction activity that is required to have general permit coverage for discharges of stormwater from construction activities; b. The support activity is not a commercial operation, nor does it serve multiple unrelated construction activities by different operators; c. The support activity does not operate beyond the completion of the last construction activity it supports; d. The support activity is identified in the registration statement at the time of general permit coverage; e. Appropriate control measures are identified in a stormwater pollution prevention plan and implemented to address the discharges from the support activity areas; and f. All applicable state, federal, and local approvals are obtained for the support activity. B. Limitations on coverage. 1. Post -construction discharges. This general permit does not authorize stormwater discharges that originate from the site after construction activities have been completed and the site, including any support activity sites covered under the general permit registration, has undergone final stabilization. Post -construction industrial stormwater discharges may need to be covered by a separate VPDES permit. Discharges mixed with nonstormwater. This general permit does not authorize discharges that are mixed with sources of nonstormwater, other than those discharges that are identified in Part I E (Authorized nonstormwater discharges) and are in compliance with this general permit. Discharges covered by another state permit. This general permit does not authorize discharges of stormwater from construction activities that have been covered under an individual permit or required to obtain coverage under an alternative general permit. Page 3 of 26 4. Impaired waters and total maximum daily load (TMDL) limitation. Nutrient and sediment impaired waters. Discharges of stormwater from construction activities to surface waters identified as impaired in the 2016 § 305(b)/303(d) Water Quality Assessment Integrated Report or for which a TMDL wasteload allocation has been established and approved prior to the term of this general permit for (i) sediment or a sediment -related parameter (i.e., total suspended solids or turbidity) or (ii) nutrients (i.e., nitrogen or phosphorus) are not eligible for coverage under this general permit unless the operator develops, implements, and maintains a stormwater pollution prevention plan (SWPPP) in accordance with Part II B 5 of this permit that minimizes the pollutants of concern and, when applicable, is consistent with the assumptions and requirements of the approved TMDL wasteload allocations and implements an inspection frequency consistent with Part II G 2 a. Polychlorinated biphenyl (PCB) impaired waters. Discharges of stormwater from construction activities that include the demolition of any structure with at least 10,000 square feet of floor space built or renovated before January 1, 1980, to surface waters identified as impaired in the 2016 § 305(b)/303(d) Water Quality Assessment Integrated Report or for which a TMDL wasteload allocation has been established and approved prior to the term of this general permit for PCB are not eligible for coverage under this general permit unless the operator develops, implements, and maintains a SWPPP in accordance with Part II B 6 of this permit that minimizes the pollutants of concern and, when applicable, is consistent with the assumptions and requirements of the approved TMDL wasteload allocations, and implements an inspection frequency consistent with Part II G 2 a. Exceptional waters limitation. Discharges of stormwater from construction activities not previously covered under the general permit effective on July 1, 2014, to exceptional waters identified in 9VAC25-260-30 A 3 c are not eligible for coverage under this general permit unless the operator develops, implements, and maintains a SWPPP in accordance with Part II B 7 of this permit and implements an inspection frequency consistent with Part II G 2 a. 6. There shall be no discharge of floating solids or visible foam in other than trace amounts C. Commingled discharges. Discharges authorized by this general permit may be commingled with other sources of stormwater that are not required to be covered under a state permit, so long as the commingled discharge is in compliance with this general permit. Discharges authorized by a separate state or VPDES permit may be commingled with discharges authorized by this general permit so long as all such discharges comply with all applicable state and VPDES permit requirements. D. Prohibition of nonstormwater discharges. Except as provided in Parts I A 2, 1 C, and I E, all discharges covered by this general permit shall be composed entirely of stormwater associated with construction activities. All other discharges including the following are prohibited: 1. Wastewater from washout of concrete; 2. Wastewater from the washout and cleanout of stucco, paint, form release oils, curing compounds, and other construction materials; Page 4 of 26 3. Fuels, oils, or other pollutants used in vehicle and equipment operation and maintenance; 4. Oils, toxic substances, or hazardous substances from spills or other releases; and 5. Soaps, solvents, or detergents used in equipment and vehicle washing. E. Authorized nonstormwater discharges. The following nonstormwater discharges from construction activities are authorized by this general permit when discharged in compliance with this general permit: 1. Discharges from firefighting activities; 2. Fire hydrant flushings; 3. Waters used to wash vehicles or equipment where soaps, solvents, or detergents have not been used and the wash water has been filtered, settled, or similarly treated prior to discharge; 4. Water used to control dust that has been filtered, settled, or similarly treated prior to discharge; 5. Potable water sources, including uncontaminated waterline flushings, managed in a manner to avoid an instream impact; 6. Routine external building wash down where soaps, solvents or detergents have not been used and the wash water has been filtered, settled, or similarly treated prior to discharge; 7. Pavement wash waters where spills or leaks of toxic or hazardous materials have not occurred (or where all spilled or leaked material has been removed prior to washing); where soaps, solvents, or detergents have not been used; and where the wash water has been filtered, settled, or similarly treated prior to discharge; 8. Uncontaminated air conditioning or compressor condensate; 9. Uncontaminated ground water or spring water; 10. Foundation or footing drains where flows are not contaminated with process materials such as solvents; 11. Uncontaminated excavation dewatering, including dewatering of trenches and excavations that have been filtered, settled, or similarly treated prior to discharge; and 12. Landscape irrigation. F. Termination of general permit coverage. 1. The operator of the construction activity shall submit a notice of termination in accordance with 9VAC25-880-60, unless a registration statement was not required to be submitted in accordance with 9VAC25-880-50 A 1 c or A 2 b for single-family detached residential structures, to the VSMP authority after one or more of the following conditions have been met: Page 5 of 26 a. Necessary permanent control measures included in the SWPPP for the site are in place and functioning effectively and final stabilization has been achieved on all portions of the site for which the operator has operational control. When applicable, long term responsibility and maintenance requirements for permanent control measures shall be recorded in the local land records prior to the submission of a complete and accurate notice of termination and the construction record drawing prepared; b. Another operator has assumed control over all areas of the site that have not been finally stabilized and obtained coverage for the ongoing discharge; c. Coverage under an alternative VPDES or state permit has been obtained; or d. For individual lots in residential construction only, final stabilization as defined in 9VAC25- 880-1 has been completed, including providing written notification to the homeowner and incorporating a copy of the notification and signed certification statement into the SWPPP, and the residence has been transferred to the homeowner. The notice of termination shall be submitted no later than 30 days after one of the above conditions in subdivision 1 of this subsection is met. 3. Termination of authorization to discharge for the conditions set forth in subdivision 1 a of this subsection shall be effective upon notification from the department that the provisions of subdivision 1 a of this subsection have been met or 60 days after submittal of a complete and accurate notice of termination in accordance with 9VAC25-880-60 C, whichever occurs first. 4. Authorization to discharge terminates at midnight on the date that the notice of termination is submitted for the conditions set forth in subdivisions 1 b through 1 d of this subsection unless otherwise notified by the VSMP authority or department. 5. The notice of termination shall be signed in accordance with Part III K of this general permit. G. Water quality protection. 1. The operator shall select, install, implement, and maintain control measures as identified in the SWPPP at the construction site that minimize pollutants in the discharge as necessary to ensure that the operator's discharge does not cause or contribute to an excursion above any applicable water quality standard. If it is determined by the department that the operator's discharges are causing, have reasonable potential to cause, or are contributing to an excursion above any applicable water quality standard, the department, in consultation with the VSMP authority, may take appropriate enforcement action and require the operator to: a. Modify or implement additional control measures in accordance with Part II C to adequately address the identified water quality concerns; b. Submit valid and verifiable data and information that are representative of ambient conditions and indicate that the receiving water is attaining water quality standards; or Page 6 of 26 c. Submit an individual permit application in accordance with 9VAC25-870-410 B 3. All written responses required under this chapter shall include a signed certification consistent with Part III K. STORMWATER POLLUTION PREVENTION PLAN A. Stormwater pollution prevent plan. A stormwater pollution prevention plan (SWPPP) shall be developed prior to the submission of a registration statement and implemented for the construction activity, including any support activity, covered by this general permit. SWPPPs shall be prepared in accordance with good engineering practices. Construction activities that are part of a larger common plan of development or sale and disturb less than one acre may utilize a SWPPP template provided by the department and need not provide a separate stormwater management plan if one has been prepared and implemented for the larger common plan of development or sale. The SWPPP requirements of this general permit may be fulfilled by incorporating by reference other plans such as a spill prevention control and countermeasure (SPCC) plan developed for the site under § 311 of the federal Clean Water Act or best management practices (BMP) programs otherwise required for the facility provided that the incorporated plan meets or exceeds the SWPPP requirements of Part II B. All plans incorporated by reference into the SWPPP become enforceable under this general permit. If a plan incorporated by reference does not contain all of the required elements of the SWPPP, the operator shall develop the missing elements and include them in the SWPPP. 3. Any operator that was authorized to discharge under the general permit effective July 1, 2014, and that intends to continue coverage under this general permit, shall update its stormwater pollution prevention plan to comply with the requirements of this general permit no later than 60 days after the date of coverage under this general permit. B. Contents. The SWPPP shall include the following items: 1. General information. a. A signed copy of the registration statement, if required, for coverage under the general VPDES permit for discharges of stormwater from construction activities; b. Upon receipt, a copy of the notice of coverage under the general VPDES permit for discharges of stormwater from construction activities (i.e., notice of coverage letter); c. Upon receipt, a copy of the general VPDES permit for discharges of stormwater from construction activities; d. A narrative description of the nature of the construction activity, including the function of the project (e.g., low density residential, shopping mall, highway, etc.); e. A legible site plan identifying: Page 7 of 26 (1) Directions of stormwater flow and approximate slopes anticipated after major grading activities; (2) Limits of land disturbance including steep slopes and natural buffers around surface waters that will not be disturbed; (3) Locations of major structural and nonstructural control measures, including sediment basins and traps, perimeter dikes, sediment barriers, and other measures intended to filter, settle, or similarly treat sediment, that will be installed between disturbed areas and the undisturbed vegetated areas in order to increase sediment removal and maximize stormwater infiltration; (4) Locations of surface waters; (5) Locations where concentrated stormwater is discharged; (6) Locations of any support activities, including (i) areas where equipment and vehicle washing, wheel wash water, and other wash water is to occur; (ii) storage areas for chemicals such as acids, fuels, fertilizers, and other lawn care chemicals; (iii) concrete wash out areas; (iv) vehicle fueling and maintenance areas; (v) sanitary waste facilities, including those temporarily placed on the construction site; and (vi) construction waste storage; and (7) When applicable, the location of the on -site rain gauge or the methodology established in consultation with the VSMP authority used to identify measurable storm events for inspection as allowed by Part II G 2 a (1) (ii) or Part II G 2 b (2). Erosion and sediment control plan. a. An erosion and sediment control plan designed and approved in accordance with the Virginia Erosion and Sediment Control Regulations (9VAC25-840), an "agreement in lieu of a plan" as defined in 9VAC25-840-10 from the VESCP authority, or an erosion and sediment control plan prepared in accordance with annual standards and specifications approved by the department. b. All erosion and sediment control plans shall include a statement describing the maintenance responsibilities required for the erosion and sediment controls used. c. An approved erosion and sediment control plan, "agreement in lieu of a plan," or erosion and sediment control plan prepared in accordance with department -approved annual standards and specifications, implemented to: (1) Control the volume and velocity of stormwater runoff within the site to minimize soil erosion; (2) Control stormwater discharges, including peak flow rates and total stormwater volume, to minimize erosion at outlets and to minimize downstream channel and stream bank erosion; Page 8 of 26 (3) Minimize the amount of soil exposed during the construction activity; (4) Minimize the disturbance of steep slopes; (5) Minimize sediment discharges from the site in a manner that addresses (i) the amount, frequency, intensity, and duration of precipitation; (ii) the nature of resulting stormwater runoff; and (iii) soil characteristics, including the range of soil particle sizes present on the site; (6) Provide and maintain natural buffers around surface waters, direct stormwater to vegetated areas to increase sediment removal, and maximize stormwater infiltration, unless infeasible; (7) Minimize soil compaction and, unless infeasible, preserve topsoil; (8) Ensure initiation of stabilization activities, as defined in 9VAC25-880-1, of disturbed areas immediately whenever any clearing, grading, excavating, or other land - disturbing activities have permanently ceased on any portion of the site, or temporarily ceased on any portion of the site and will not resume for a period exceeding 14 days; and (9) Utilize outlet structures that withdraw stormwater from the surface (i.e., above the permanent pool or wet storage water surface elevation), unless infeasible, when discharging from sediment basins or sediment traps. 3. Stormwater management plan. a. Except for those projects identified in Part II B 3 b, a stormwater management plan approved by the VSMP authority as authorized under the Virginia Stormwater Management Program (VSMP) Regulation (9VAC25-870), or an "agreement in lieu of a stormwater management plan" as defined in 9VAC25-870-10 from the VSMP authority, or a stormwater management plan prepared in accordance with annual standards and specifications approved by the department. b. For any operator meeting the conditions of 9VAC25-870-47 B of the VSMP regulation, an approved stormwater management plan is not required. In lieu of an approved stormwater management plan, the SWPPP shall include a description of, and all necessary calculations supporting, all post -construction stormwater management measures that will be installed prior to the completion of the construction process to control pollutants in stormwater discharges after construction operations have been completed. Structural measures should be placed on upland soils to the degree possible. Such measures must be designed and installed in accordance with applicable VESCP authority, VSMP authority, state, and federal requirements, and any necessary permits must be obtained. Pollution prevention plan. A pollution prevention plan that addresses potential pollutant - generating activities that may reasonably be expected to affect the quality of stormwater discharges from the construction activity, including any support activity. The pollution prevention plan shall: a. Identify the potential pollutant -generating activities and the pollutant that is expected to be exposed to stormwater; Page 9 of 26 b. Describe the location where the potential pollutant -generating activities will occur, or if identified on the site plan, reference the site plan; c. Identify all nonstormwater discharges, as authorized in Part I E of this general permit, that are or will be commingled with stormwater discharges from the construction activity, including any applicable support activity; d. Identify the person responsible for implementing the pollution prevention practice or practices for each pollutant -generating activity (if other than the person listed as the qualified personnel); e. Describe the pollution prevention practices and procedures that will be implemented to: (1) Prevent and respond to leaks, spills, and other releases including (i) procedures for expeditiously stopping, containing, and cleaning up spills, leaks, and other releases; and (ii) procedures for reporting leaks, spills, and other releases in accordance with Part III G; (2) Prevent the discharge of spilled and leaked fuels and chemicals from vehicle fueling and maintenance activities (e.g., providing secondary containment such as spill berms, decks, spill containment pallets, providing cover where appropriate, and having spill kits readily available); (3) Prevent the discharge of soaps, solvents, detergents, and wash water from construction materials, including the clean-up of stucco, paint, form release oils, and curing compounds (e.g., providing (i) cover (e.g., plastic sheeting or temporary roofs) to prevent contact with stormwater; (ii) collection and proper disposal in a manner to prevent contact with stormwater; and (iii) a similarly effective means designed to prevent discharge of these pollutants); (4) Minimize the discharge of pollutants from vehicle and equipment washing, wheel wash water, and other types of washing (e.g., locating activities away from surface waters and stormwater inlets or conveyance and directing wash waters to sediment basins or traps, using filtration devices such as filter bags or sand filters, or using similarly effective controls); (5) Direct concrete wash water into a leak -proof container or leak -proof settling basin. The container or basin shall be designed so that no overflows can occur due to inadequate sizing or precipitation. Hardened concrete wastes shall be removed and disposed of in a manner consistent with the handling of other construction wastes. Liquid concrete wastes shall be removed and disposed of in a manner consistent with the handling of other construction wash waters and shall not be discharged to surface waters; (6) Minimize the discharge of pollutants from storage, handling, and disposal of construction products, materials, and wastes including (i) building products such as asphalt sealants, copper flashing, roofing materials, adhesives, and concrete admixtures; (ii) pesticides, herbicides, insecticides, fertilizers, and landscape Page 10 of 26 materials; and (iii) construction and domestic wastes such as packaging materials, scrap construction materials, masonry products, timber, pipe and electrical cuttings, plastics, Styrofoam, concrete, and other trash or building materials; (7) Prevent the discharge of fuels, oils, and other petroleum products, hazardous or toxic wastes, waste concrete, and sanitary wastes; (8) Address any other discharge from the potential pollutant -generating activities not addressed above; (9) Minimize the exposure of waste materials to precipitation by closing or covering waste containers during precipitation events and at the end of the business day, or implementing other similarly effective practices. Minimization of exposure is not required in cases where the exposure to precipitation will not result in a discharge of pollutants; and f. Describe procedures for providing pollution prevention awareness of all applicable wastes, including any wash water, disposal practices, and applicable disposal locations of such wastes, to personnel in order to comply with the conditions of this general permit. The operator shall implement the procedures described in the SWPPP. SWPPP requirements for discharges to nutrient and sediment impaired waters. For discharges to surface waters (i) identified as impaired in the 2016 § 305(b)/303(d) Water Quality Assessment Integrated Report or (ii) with an applicable TMDL wasteload allocation established and approved prior to the term of this general permit for sediment for a sediment - related parameter (i.e., total suspended solids or turbidity) or nutrients (i.e., nitrogen or phosphorus), the operator shall: a. Identify the impaired waters, approved TMDLs, and pollutants of concern in the SWPPP; and b. Provide clear direction in the SWPPP that: (1) Permanent or temporary soil stabilization shall be applied to denuded areas within seven days after final grade is reached on any portion of the site; (2) Nutrients shall be applied in accordance with manufacturer's recommendations or an approved nutrient management plan and shall not be applied during rainfall events; and (3) A modified inspection schedule shall be implemented in accordance with Part II G 2 a. SWPPP requirements for discharges to polychlorinated biphenyl (PCB) impaired waters. For discharges from construction activities that include the demolition of any structure with at least 10,000 square feet of floor space built or renovated before January 1, 1980, to surface waters (i) identified as impaired in the 2016 § 305(b)/303(d) Water Quality Assessment Integrated Report or (ii) with an applicable TMDL wasteload allocation established and approved prior to the term of this general permit for PCB, the operator shall: Page 11 of 26 a. Identify the impaired waters, approved TMDLs, and pollutant of concern in the SWPPP; b. Implement the approved erosion and sediment control plan in accordance with Part II B 2; c. Dispose of waste materials in compliance with applicable state, federal, and local requirements; and d. Implement a modified inspection schedule in accordance with Part II G 2 a. 7. SWPPP requirements for discharges to exceptional waters. For discharges to surface waters identified in 9VAC25-260-30 A 3 c as an exceptional water, the operator shall: a. Identify the exceptional surface waters in the SWPPP; and b. Provide clear direction in the SWPPP that: (1) Permanent or temporary soil stabilization shall be applied to denuded areas within seven days after final grade is reached on any portion of the site; (2) Nutrients shall be applied in accordance with manufacturer's recommendations or an approved nutrient management plan and shall not be applied during rainfall events; and (3) A modified inspection schedule shall be implemented in accordance with Part II G 2 a. 8. Identification of qualified personnel. The name, phone number, and qualifications of the qualified personnel conducting inspections required by this general permit. 9. Delegation of authority. The individuals or positions with delegated authority, in accordance with Part III K, to sign inspection reports or modify the SWPPP. 10. SWPPP signature. The SWPPP shall be signed and dated in accordance with Part III K. C. SWPPP amendments, modification, and updates. 1. The operator shall amend the SWPPP whenever there is a change in the design, construction, operation, or maintenance that has a significant effect on the discharge of pollutants to surface waters and that has not been previously addressed in the SWPPP. The SWPPP shall be amended if, during inspections or investigations by the operator's qualified personnel, or by local, state, or federal officials, it is determined that the existing control measures are ineffective in minimizing pollutants in discharges from the construction activity. Revisions to the SWPPP shall include additional or modified control measures designed and implemented to correct problems identified. If approval by the VESCP authority, VSMP authority, or department is necessary for the control measure, revisions to the SWPPP shall be completed no later than seven calendar days following approval. Implementation of these additional or modified control measures shall be accomplished as described in Part II H. Page 12 of 26 3. The SWPPP shall clearly identify the contractors that will implement and maintain each control measure identified in the SWPPP. The SWPPP shall be amended to identify any new contractor that will implement and maintain a control measure. 4. The operator shall update the SWPPP as soon as possible but no later than seven days following any modification to its implementation. All modifications or updates to the SWPPP shall be noted and shall include the following items: a. A record of dates when: (1) Major grading activities occur; (2) Construction activities temporarily or permanently cease on a portion of the site; and (3) Stabilization measures are initiated; b. Documentation of replaced or modified controls where periodic inspections or other information have indicated that the controls have been used inappropriately or incorrectly and were modified; c. Areas that have reached final stabilization and where no further SWPPP or inspection requirements apply; d. All properties that are no longer under the legal control of the operator and the dates on which the operator no longer had legal control over each property; e. The date of any prohibited discharges, the discharge volume released, and what actions were taken to minimize the impact of the release; f. Measures taken to prevent the reoccurrence of any prohibited discharge; and g. Measures taken to address any evidence identified as a result of an inspection required under Part II G. 5. Amendments, modifications, or updates to the SWPPP shall be signed in accordance with Part III K. D. Public notification. Upon commencement of land disturbance, the operator shall post conspicuously a copy of the notice of coverage letter near the main entrance of the construction activity. For linear projects, the operator shall post the notice of coverage letter at a publicly accessible location near an active part of the construction project (e.g., where a pipeline crosses a public road). The operator shall maintain the posted information until termination of general permit coverage as specified in Part I F. E. SWPPP availability. 1. Operators with day-to-day operational control over SWPPP implementation shall have a copy of the SWPPP available at a central location on -site for use by those identified as having responsibilities under the SWPPP whenever they are on the construction site. Page 13 of 26 The operator shall make the SWPPP and all amendments, modifications, and updates available upon request to the department, the VSMP authority, the EPA, the VESCP authority, local government officials, or the operator of a municipal separate storm sewer system receiving discharges from the construction activity. If an on -site location is unavailable to store the SWPPP when no personnel are present, notice of the SWPPP's location shall be posted near the main entrance of the construction site. The operator shall make the SWPPP available for public review in an electronic format or in hard copy. Information for public access to the SWPPP shall be posted and maintained in accordance with Part II D. If not provided electronically, public access to the SWPPP may be arranged upon request at a time and at a publicly accessible location convenient to the operator or his designee but shall be no less than once per month and shall be during normal business hours. Information not required to be contained within the SWPPP by this general permit is not required to be released. F. SWPPP implementation. The operator shall implement the SWPPP and subsequent amendments, modifications, and updates from commencement of land disturbance until termination of general permit coverage as specified in Part I F. All control measures shall be properly maintained in effective operating condition in accordance with good engineering practices and, where applicable, manufacturer specifications. If a site inspection required by Part II G identifies a control measure that is not operating effectively, corrective actions shall be completed as soon as practicable, but no later than seven days after discovery or a longer period as established by the VSMP authority, to maintain the continued effectiveness of the control measures. If site inspections required by Part II G identify an existing control measure that needs to be modified or if an additional or alternative control measure is necessary for any reason, implementation shall be completed prior to the next anticipated measurable storm event. If implementation prior to the next anticipated measurable storm event is impracticable, then additional or alternative control measures shall be implemented as soon as practicable, but no later than seven days after discovery or a longer period as established by the VSMP authority. G. SWPPP Inspections. 1. Personnel responsible for on -site and off -site inspections. Inspections required by this general permit shall be conducted by the qualified personnel identified by the operator in the SWPPP. The operator is responsible for ensuring that the qualified personnel conduct the inspection. 2. Inspection schedule. a. For construction activities that discharge to a surface water identified in Part 11 B 5 and B 6 as impaired or having an approved TMDL or Part I B 7 as exceptional, the following inspection schedule requirements apply: (1) Inspections shall be conducted at a frequency of (i) at least once every four business days or (ii) at least once every five business days and no later than 24 hours following a measurable storm event. In the event that a measurable storm event occurs when Page 14 of 26 there are more than 24 hours between business days, the inspection shall be conducted on the next business day; and (2) Representative inspections as authorized in Part II G 2 d shall not be allowed. b. Except as specified in Part II G 2 a, inspections shall be conducted at a frequency of: (1) At least once every five business days; or (2) At least once every 10 business days and no later than 24 hours following a measurable storm event. In the event that a measurable storm event occurs when there are more than 24 hours between business days, the inspection shall be conducted on the next business day. c. Where areas have been temporarily stabilized or land -disturbing activities will be suspended due to continuous frozen ground conditions and stormwater discharges are unlikely, the inspection frequency described in Part II G 2 a and 2 b may be reduced to once per month. If weather conditions (such as above freezing temperatures or rain or snow events) make discharges likely, the operator shall immediately resume the regular inspection frequency. d. Except as prohibited in Part II G 2 a (2), representative inspections may be utilized for utility line installation, pipeline construction, or other similar linear construction activities provided that: (1) Temporary or permanent soil stabilization has been installed and vehicle access may compromise the temporary or permanent soil stabilization and potentially cause additional land disturbance increasing the potential for erosion; (2) Inspections occur on the same frequency as other construction activities; (3) Control measures are inspected along the construction site 0.25 miles above and below each access point (i.e., where a roadway, undisturbed right-of-way, or other similar feature intersects the construction activity and access does not compromise temporary or permanent soil stabilization); and (4) Inspection locations are provided in the inspection report required by Part II G. e. If adverse weather causes the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. Any time inspections are delayed due to adverse weather conditions, evidence of the adverse weather conditions shall be included in the SWPPP with the dates of occurrence. 3. Inspection requirements. a. As part of the inspection, the qualified personnel shall: (1) Record the date and time of the inspection and, when applicable, the date and rainfall amount of the last measurable storm event; Page 15 of 26 (2) Record the information and a description of any discharges occurring at the time of the inspection or evidence of discharges occurring prior to the inspection; (3) Record any land -disturbing activities that have occurred outside of the approved erosion and sediment control plan; (4) Inspect the following for installation in accordance with the approved erosion and sediment control plan, identification of any maintenance needs, and evaluation of effectiveness in minimizing sediment discharge, including whether the control has been inappropriately or incorrectly used: (a) All perimeter erosion and sediment controls, such as silt fence; (b) Soil stockpiles, when applicable, and borrow areas for stabilization or sediment trapping measures; (c) Completed earthen structures, such as dams, dikes, ditches, and diversions for stabilization and effective impoundment or flow control; (d) Cut and fill slopes; (e) Sediment basins and traps, sediment barriers, and other measures installed to control sediment discharge from stormwater; (f) Temporary or permanent channels, flumes, or other slope drain structures installed to convey concentrated runoff down cut and fill slopes; (g) Storm inlets that have been made operational to ensure that sediment laden stormwater does not enter without first being filtered or similarly treated; and (h) Construction vehicle access routes that intersect or access paved or public roads for minimizing sediment tracking; (5) Inspect areas that have reached final grade or that will remain dormant for more than 14 days to ensure: (a) Initiation of stabilization activities have occurred immediately, as defined in 9VAC25-880-1; and (b) Stabilization activities have been completed within seven days of reaching grade or stopping work; (6) Inspect for evidence that the approved erosion and sediment control plan, "agreement in lieu of a plan," or erosion and sediment control plan prepared in accordance with department -approved annual standards and specifications has not been properly implemented. This includes: Page 16 of 26 (a) Concentrated flows of stormwater in conveyances such as rills, rivulets, or channels that have not been filtered, settled, or similarly treated prior to discharge, or evidence thereof; (b) Sediment laden or turbid flows of stormwater that have not been filtered or settled to remove sediments prior to discharge; (c) Sediment deposition in areas that drain to unprotected stormwater inlets or catch basins that discharge to surface waters. Inlets and catch basins with failing sediment controls due to improper installation, lack of maintenance, or inadequate design are considered unprotected; (d) Sediment deposition on any property (including public and private streets) outside of the construction activity covered by this general permit; (e) Required stabilization has not been initiated or completed or is not effective on portions of the site; (f) Sediment basins without adequate wet or dry storage volume or sediment basins that allow the discharge of stormwater from below the surface of the wet storage portion of the basin; (g) Sediment traps without adequate wet or dry storage or sediment traps that allow the discharge of stormwater from below the surface of the wet storage portion of the trap; and (h) Land disturbance or sediment deposition outside of the approved area to be disturbed; (7) Inspect pollutant generating activities identified in the pollution prevention plan for the proper implementation, maintenance, and effectiveness of the procedures and practices; (8) Identify any pollutant generating activities not identified in the pollution prevention plan; and (9) Identify and document the presence of any evidence of the discharge of pollutants prohibited by this general permit. 4. Inspection report. Each inspection report shall include the following items: a. The date and time of the inspection and, when applicable, the date and rainfall amount of the last measurable storm event; b. Summarized findings of the inspection; c. The locations of prohibited discharges; d. The locations of control measures that require maintenance; Page 17 of 26 e. The locations of control measures that failed to operate as designed or proved inadequate or inappropriate for a particular location; f. The locations where any evidence identified under Part II G 3 a (6) exists; g. The locations where any additional control measure is needed; h. A list of corrective actions required (including any changes to the SWPPP that are necessary) as a result of the inspection or to maintain permit compliance; i. Documentation of any corrective actions required from a previous inspection that have not been implemented; and The date and signature of the qualified personnel and the operator or its duly authorized representative. 5. The inspection report shall be included into the SWPPP no later than four business days after the inspection is complete. The inspection report and any actions taken in accordance with Part II shall be retained by the operator as part of the SWPPP for at least three years from the date that general permit coverage expires or is terminated. The inspection report shall identify any incidents of noncompliance. Where an inspection report does not identify any incidents of noncompliance, the report shall contain a certification that the construction activity is in compliance with the SWPPP and this general permit. The report shall be signed in accordance with Part III K of this general permit. H. Corrective actions. The operator shall implement the corrective actions identified as a result of an inspection as soon as practicable but no later than seven days after discovery or a longer period as approved by the VSMP authority. If approval of a corrective action by a regulatory authority (e.g., VSMP authority, VESCP authority, or the department) is necessary, additional control measures shall be implemented to minimize pollutants in stormwater discharges until such approvals can be obtained. The operator may be required to remove accumulated sediment deposits located outside of the construction activity covered by this general permit as soon as practicable in order to minimize environmental impacts. The operator shall notify the VSMP authority and the department as well as obtain all applicable federal, state, and local authorizations, approvals, and permits prior to the removal of sediments accumulated in surface waters including wetlands. Page 18 of 26 PART III CONDITIONS APPLICABLE TO ALL VPDES PERMITS NOTE: Discharge monitoring is not required for this general permit. If the operator chooses to monitor stormwater discharges or control measures, the operator shall comply with the requirements of subsections A, B, and C, as appropriate. A. Monitoring. 1. Samples and measurements taken for the purpose of monitoring shall be representative of the monitoring activity. Monitoring shall be conducted according to procedures approved under 40 CFR Part 136 or alternative methods approved by the U.S. Environmental Protection Agency, unless other procedures have been specified in this general permit. Analyses performed according to test procedures approved under 40 CFR Part 136 shall be performed by an environmental laboratory certified under regulations adopted by the Department of General Services (1 VAC30-45 or 1 VAC30-46). 3. The operator shall periodically calibrate and perform maintenance procedures on all monitoring and analytical instrumentation at intervals that will ensure accuracy of measurements. B. Records. 1. Monitoring records and reports shall include a. The date, exact place, and time of sampling or measurements; b. The individuals who performed the sampling or measurements; c. The dates and times analyses were performed; d. The individuals who performed the analyses; e. The analytical techniques or methods used; and f. The results of such analyses. 2. The operator shall retain records of all monitoring information, including all calibration and maintenance records and all original strip chart recordings for continuous monitoring instrumentation, copies of all reports required by this general permit, and records of all data used to complete the registration statement for this general permit, for a period of at least three years from the date of the sample, measurement, report or request for coverage. This period of retention shall be extended automatically during the course of any unresolved litigation regarding the regulated activity or regarding control standards applicable to the operator, or as requested by the board. C. Reporting monitoring results. Page 19 of 26 1. The operator shall update the SWPPP to include the results of the monitoring as may be performed in accordance with this general permit, unless another reporting schedule is specified elsewhere in this general permit. 2. Monitoring results shall be reported on a discharge monitoring report (DMR); on forms provided, approved or specified by the department; or in any format provided that the date, location, parameter, method, and result of the monitoring activity are included. If the operator monitors any pollutant specifically addressed by this general permit more frequently than required by this general permit using test procedures approved under 40 CFR Part 136 or using other test procedures approved by the U.S. Environmental Protection Agency or using procedures specified in this general permit, the results of this monitoring shall be included in the calculation and reporting of the data submitted in the DMR or reporting form specified by the department. 4. Calculations for all limitations which require averaging of measurements shall utilize an arithmetic mean unless otherwise specified in this general permit. D. Duty to provide information. The operator shall furnish, within a reasonable time, any information which the board may request to determine whether cause exists for terminating this general permit coverage or to determine compliance with this general permit. The board, department, EPA, or VSMP authority may require the operator to furnish, upon request, such plans, specifications, and other pertinent information as may be necessary to determine the effect of the wastes from his discharge on the quality of surface waters, or such other information as may be necessary to accomplish the purposes of the CWA and the Virginia Stormwater Management Act. The operator shall also furnish to the board, department, EPA, or VSMP authority, upon request, copies of records required to be kept by this general permit. E. Compliance schedule reports. Reports of compliance or noncompliance with, or any progress reports on, interim and final requirements contained in any compliance schedule of this general permit shall be submitted no later than 14 days following each schedule date. F. Unauthorized stormwater discharges. Pursuant to § 62.1-44.5 of the Code of Virginia, except in compliance with a state permit issued by the department, it shall be unlawful to cause a stormwater discharge from a construction activity. G. Reports of unauthorized discharges. Any operator who discharges or causes or allows a discharge of sewage, industrial waste, other wastes or any noxious or deleterious substance or a hazardous substance or oil in an amount equal to or in excess of a reportable quantity established under either 40 CFR Part 110, 40 CFR Part 117, 40 CFR Part 302, or § 62.1-44.34:19 of the Code of Virginia that occurs during a 24-hour period into or upon surface waters or who discharges or causes or allows a discharge that may reasonably be expected to enter surface waters, shall notify the Department of Environmental Quality of the discharge immediately upon discovery of the discharge, but in no case later than within 24 hours after said discovery. A written report of the unauthorized discharge shall be submitted to the department and the VSMP authority within five days of discovery of the discharge. The written report shall contain: 1. A description of the nature and location of the discharge; 2. The cause of the discharge; Page 20 of 26 3. The date on which the discharge occurred; 4. The length of time that the discharge continued; 5. The volume of the discharge; 6. If the discharge is continuing, how long it is expected to continue; 7. If the discharge is continuing, what the expected total volume of the discharge will be; and Any steps planned or taken to reduce, eliminate and prevent a recurrence of the present discharge or any future discharges not authorized by this general permit. Discharges reportable to the department and the VSMP authority under the immediate reporting requirements of other regulations are exempted from this requirement. H. Reports of unusual or extraordinary discharges. If any unusual or extraordinary discharge including a "bypass" or "upset," as defined in this general permit, should occur from a facility and the discharge enters or could be expected to enter surface waters, the operator shall promptly notify, in no case later than within 24 hours, the department and the VSMP authority by telephone after the discovery of the discharge. This notification shall provide all available details of the incident, including any adverse effects on aquatic life and the known number of fish killed. The operator shall reduce the report to writing and shall submit it to the department and the VSMP authority within five days of discovery of the discharge in accordance with Part III 12. Unusual and extraordinary discharges include any discharge resulting from: 1. Unusual spillage of materials resulting directly or indirectly from processing operations; 2. Breakdown of processing or accessory equipment; 3. Failure or taking out of service of some or all of the facilities; and 4. Flooding or other acts of nature. I. Reports of noncompliance. The operator shall report any noncompliance which may adversely affect surface waters or may endanger public health. An oral report to the department and the VSMP authority shall be provided within 24 hours from the time the operator becomes aware of the circumstances. The following shall be included as information that shall be reported within 24 hours under this subdivision: a. Any unanticipated bypass; and b. Any upset that causes a discharge to surface waters. 2. A written report shall be submitted within five days and shall contain: a. A description of the noncompliance and its cause; Page 21 of 26 b. The period of noncompliance, including exact dates and times, and if the noncompliance has not been corrected, the anticipated time it is expected to continue; and c. Steps taken or planned to reduce, eliminate, and prevent reoccurrence of the noncompliance. The department may waive the written report on a case -by -case basis for reports of noncompliance under Part III I if the oral report has been received within 24 hours and no adverse impact on surface waters has been reported. 3. The operator shall report all instances of noncompliance not reported under Part III 1 1 or 2 in writing as part of the SWPPP. The reports shall contain the information listed in Part 111 1 2. NOTE: The reports required in Part III G, H and I shall be made to the department and the VSMP authority. Reports may be made by telephone, email, or by fax. For reports outside normal working hours, leaving a recorded message shall fulfill the immediate reporting requirement. For emergencies, the Virginia Department of Emergency Management maintains a 24-hour telephone service at 1-800-468-8892. 4. Where the operator becomes aware of a failure to submit any relevant facts, or submittal of incorrect information in any report, including a registration statement, to the department or the VSMP authority, the operator shall promptly submit such facts or correct information. J. Notice of planned changes. 1. The operator shall give notice to the department and the VSMP authority as soon as possible of any planned physical alterations or additions to the permitted facility or activity. Notice is required only when: a. The operator plans an alteration or addition to any building, structure, facility, or installation that may meet one of the criteria for determining whether a facility is a new source in 9VAC25-870-420; b. The operator plans an alteration or addition that would significantly change the nature or increase the quantity of pollutants discharged. This notification applies to pollutants that are not subject to effluent limitations in this general permit; or 2. The operator shall give advance notice to the department and VSMP authority of any planned changes in the permitted facility or activity, which may result in noncompliance with state permit requirements. K. Signatory requirements. 1. Registration statement. All registration statements shall be signed as follows: a. For a corporation: by a responsible corporate officer. For the purpose of this chapter, a responsible corporate officer means: (i) a president, secretary, treasurer, or vice-president of the corporation in charge of a principal business function, or any other person who performs similar policy -making or decision -making functions for the corporation; or (ii) the manager of one or more manufacturing, production, or operating facilities, provided the Page 22 of 26 manager is authorized to make management decisions that govern the operation of the regulated facility including having the explicit or implicit duty of making major capital investment recommendations, and initiating and directing other comprehensive measures to assure long-term compliance with environmental laws and regulations; the manager can ensure that the necessary systems are established or actions taken to gather complete and accurate information for state permit application requirements; and where authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures; b. For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or c. For a municipality, state, federal, or other public agency: by either a principal executive officer or ranking elected official. For purposes of this chapter, a principal executive officer of a public agency includes (i) the chief executive officer of the agency or (ii) a senior executive officer having responsibility for the overall operations of a principal geographic unit of the agency. 2. Reports and other information. All reports required by this general permit, including SWPPPs, and other information requested by the board or the department shall be signed by a person described in Part III K 1 or by a duly authorized representative of that person. A person is a duly authorized representative only if: a. The authorization is made in writing by a person described in Part III K 1; b. The authorization specifies either an individual or a position having responsibility for the overall operation of the regulated facility or activity such as the position of plant manager, operator of a well or a well field, superintendent, position of equivalent responsibility, or an individual or position having overall responsibility for environmental matters for the operator. (A duly authorized representative may thus be either a named individual or any individual occupying a named position); and c. The signed and dated written authorization is included in the SWPPP. A copy shall be provided to the department and VSMP authority, if requested. 3. Changes to authorization. If an authorization under Part III K 2 is no longer accurate because a different individual or position has responsibility for the overall operation of the construction activity, a new authorization satisfying the requirements of Part III K 2 shall be submitted to the VSMP authority as the administering entity for the board prior to or together with any reports or information to be signed by an authorized representative. 4. Certification. Any person signing a document under Part III K 1 or 2 shall make the following certification: "I certify under penalty of law that I have read and understand this document and that this document and all attachments were prepared in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant Page 23 of 26 penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations." L. Duty to comply. The operator shall comply with all conditions of this general permit. Any state permit noncompliance constitutes a violation of the Virginia Stormwater Management Act and the Clean Water Act, except that noncompliance with certain provisions of this general permit may constitute a violation of the Virginia Stormwater Management Act but not the Clean Water Act. Permit noncompliance is grounds for enforcement action; for state permit coverage, termination, revocation and reissuance, or modification; or denial of a state permit renewal application. The operator shall comply with effluent standards or prohibitions established under § 307(a) of the Clean Water Act for toxic pollutants within the time provided in the regulations that establish these standards or prohibitions or standards for sewage sludge use or disposal, even if this general permit has not yet been modified to incorporate the requirement. M. Duty to reapply. If the operator wishes to continue an activity regulated by this general permit after the expiration date of this general permit, the operator shall submit a new registration statement at least 60 days before the expiration date of the existing general permit, unless permission for a later date has been granted by the board. The board shall not grant permission for registration statements to be submitted later than the expiration date of the existing general permit. N. Effect of a state permit. This general permit does not convey any property rights in either real or personal property or any exclusive privileges, nor does it authorize any injury to private property or invasion of personal rights, or any infringement of federal, state or local law or regulations. O. State law. Nothing in this general permit shall be construed to preclude the institution of any legal action under, or relieve the operator from any responsibilities, liabilities, or penalties established pursuant to any other state law or regulation or under authority preserved by § 510 of the Clean Water Act. Except as provided in general permit conditions on "bypassing" (Part III U) and "upset' (Part III V), nothing in this general permit shall be construed to relieve the operator from civil and criminal penalties for noncompliance. P. Oil and hazardous substance liability. Nothing in this general permit shall be construed to preclude the institution of any legal action or relieve the operator from any responsibilities, liabilities, or penalties to which the operator is or may be subject under §§ 62.1-44.34:14 through 62.1-44.34:23 of the State Water Control Law or § 311 of the Clean Water Act. Q. Proper operation and maintenance. The operator shall at all times properly operate and maintain all facilities and systems of treatment and control (and related appurtenances), which are installed or used by the operator to achieve compliance with the conditions of this general permit. Proper operation and maintenance also includes effective plant performance, adequate funding, adequate staffing, and adequate laboratory and process controls, including appropriate quality assurance procedures. This provision requires the operation of back-up or auxiliary facilities or similar systems, which are installed by the operator only when the operation is necessary to achieve compliance with the conditions of this general permit. R. Disposal of solids or sludges. Solids, sludges or other pollutants removed in the course of treatment or management of pollutants shall be disposed of in a manner so as to prevent any pollutant from such materials from entering surface waters and in compliance with all applicable state and federal laws and regulations. Page 24 of 26 S. Duty to mitigate. The operator shall take all steps to minimize or prevent any discharge in violation of this general permit that has a reasonable likelihood of adversely affecting human health or the environment. T. Need to halt or reduce activity not a defense. It shall not be a defense for an operator in an enforcement action that it would have been necessary to halt or reduce the permitted activity in order to maintain compliance with the conditions of this general permit. U. Bypass. 1. 'Bypass," as defined in 9VAC25-870-10, means the intentional diversion of waste streams from any portion of a treatment facility. The operator may allow any bypass to occur that does not cause effluent limitations to be exceeded, but only if it also is for essential maintenance to ensure efficient operation. These bypasses are not subject to the provisions of Part III U 2 and 3. 2. Notice. a. Anticipated bypass. If the operator knows in advance of the need for a bypass, the operator shall submit prior notice to the department, if possible at least 10 days before the date of the bypass. b. Unanticipated bypass. The operator shall submit notice of an unanticipated bypass as required in Part III I. 3. Prohibition of bypass. a. Except as provided in Part III U 1, bypass is prohibited, and the board or department may take enforcement action against an operator for bypass unless: (1) Bypass was unavoidable to prevent loss of life, personal injury, or severe property damage. Severe property damage means substantial physical damage to property, damage to the treatment facilities that causes them to become inoperable, or substantial and permanent loss of natural resources that can reasonably be expected to occur in the absence of a bypass. Severe property damage does not mean economic loss caused by delays in production; (2) There were no feasible alternatives to the bypass, such as the use of auxiliary treatment facilities, retention of untreated wastes, or maintenance during normal periods of equipment downtime. This condition is not satisfied if adequate back-up equipment should have been installed in the exercise of reasonable engineering judgment to prevent a bypass that occurred during normal periods of equipment downtime or preventive maintenance; and (3) The operator submitted notices as required under Part III U 2. b. The department may approve an anticipated bypass, after considering its adverse effects, if the department determines that it will meet the three conditions listed in Part III U 3 a. Page 25 of 26 V. Upset. 1. An "upset," as defined in 9VAC25-870-10, means an exceptional incident in which there is unintentional and temporary noncompliance with technology -based state permit effluent limitations because of factors beyond the reasonable control of the operator. An upset does not include noncompliance to the extent caused by operational error, improperly designed treatment facilities, inadequate treatment facilities, lack of preventive maintenance, or careless or improper operation. 2. An upset constitutes an affirmative defense to an action brought for noncompliance with technology -based state permit effluent limitations if the requirements of Part III V 4 are met. A determination made during administrative review of claims that noncompliance was caused by upset, and before an action for noncompliance, is not a final administrative action subject to judicial review. 3. An upset does not include noncompliance to the extent caused by operational error, improperly designed treatment facilities, inadequate treatment facilities, lack of preventative maintenance, or careless or improper operation. 4. An operator who wishes to establish the affirmative defense of upset shall demonstrate, through properly signed, contemporaneous operating logs or other relevant evidence that: a. An upset occurred and that the operator can identify the cause of the upset; b. The permitted facility was at the time being properly operated; c. The operator submitted notice of the upset as required in Part III I; and d. The operator complied with any remedial measures required under Part III S. 5. In any enforcement proceeding, the operator seeking to establish the occurrence of an upset has the burden of proof. W. Inspection and entry. The operator shall allow the department as the board's designee, the VSMP authority, EPA, or an authorized representative of either entity (including an authorized contractor), upon presentation of credentials and other documents as may be required by law to: 1. Enter upon the operator's premises where a regulated facility or activity is located or conducted, or where records shall be kept under the conditions of this general permit; 2. Have access to and copy, at reasonable times, any records that shall be kept under the conditions of this general permit; 3. Inspect and photograph at reasonable times any facilities, equipment (including monitoring and control equipment), practices, or operations regulated or required under this general permit; and 4. Sample or monitor at reasonable times, for the purposes of ensuring state permit compliance or as otherwise authorized by the Clean Water Act or the Virginia Stormwater Management Act, any substances or parameters at any location. Page 26 of 26 For purposes of this section, the time for inspection shall be deemed reasonable during regular business hours, and whenever the facility is discharging. Nothing contained herein shall make an inspection unreasonable during an emergency. X. State permit actions. State permit coverage may be modified, revoked and reissued, or terminated for cause. The filing of a request by the operator for a state permit modification, revocation and reissuance, or termination, or a notification of planned changes or anticipated noncompliance does not stay any state permit condition. Y. Transfer of state permit coverage. 1. State permits are not transferable to any person except after notice to the department. Except as provided in Part III Y 2, a state permit may be transferred by the operator to a new operator only if the state permit has been modified or revoked and reissued, or a minor modification made, to identify the new operator and incorporate such other requirements as may be necessary under the Virginia Stormwater Management Act and the Clean Water Act. As an alternative to transfers under Part III Y 1, this state permit may be automatically transferred to a new operator if: a. The current operator notifies the department at least 30 days in advance of the proposed transfer of the title to the facility or property; b. The notice includes a written agreement between the existing and new operators containing a specific date for transfer of state permit responsibility, coverage, and liability between them; and c. The department does not notify the existing operator and the proposed new operator of its intent to modify or revoke and reissue the state permit. If this notice is not received, the transfer is effective on the date specified in the agreement mentioned in Part III Y 2 b. 3. For ongoing construction activity involving a change of operator, the new operator shall accept and maintain the existing SWPPP, or prepare and implement a new SWPPP prior to taking over operations at the site. Z. Severability. The provisions of this general permit are severable, and if any provision of this general permit or the application of any provision of this state permit to any circumstance, is held invalid, the application of such provision to other circumstances and the remainder of this general permit shall not be affected thereby. Section 12. Inspection logs (Provide templates for your inspections. Requirements are listed in 9VAC25-880-70, Part II, section B and F.) Issued — 10/2014 Stormwater Pollution Prevention Plan (S WPPP) Albemarle County VAR 10XXXX VPDES EROSION CONTROL INSPECTION FORM Project Name: New School/111222 Permittee: New School Public School Contractor: Location: New Town, Virginia Weather: WSSI #: XXXXX.XX XYZ Contracting Sunny, 70's Wetland Sr F" end Solmions,ln" .at a �12 company Date: 03/01/2017 Time: 1:00 PM Weekly Rainfall (in.): 0.75" Item# Inspection Questions N/Al YESz NO 1. Have all denuded areas requiring temporary or permanent stabilization been stabilized? ❑ ❑X ❑ 2 Have disposal/borrow and soil stockpiles (on -site and off -site) been stabilized with seeding and/or ❑ ❑X ❑ protected with sediment trapping measures? Are off -site areas included in the E&S plans? 3. Does permanent vegetation provide adequate stabilization for completed project areas? X❑ ❑ ❑ 4 Have perimeter controls been constructed as a first step in land disturbing activities (i es clearing OR ❑ X❑ ❑ grubbing)? 5 Are perimeter and other erosion and sediment control structures and systems being maintained, ❑ ❑ X❑ inspected and repaired to ensure functionality? AL 6. Have earthen structures, such as dams, dikes, and diversions, been imm Aately stabiliz ❑ X❑ ❑ 7. Have sediment basins and traps been constructed according to plans, specifications, and/ors ards? ❑ X❑ ❑ 8. Are finished cut and fill slopes adequately stabilized? X❑ ❑ ❑ 9 Is concentrated water flowing through adequate slope drains, es, or n ' g erodible annels on cut or ❑ ❑ fill slopes? 10. Do slope faces have drainage or protection from water seeps? "` 0 ❑ ❑ 11. Do all operational storm sewer and culvert inlets have inleitpragWion in rdance with plans, ❑ ❑ 0 specifications, and/or standards? 12. Are stormwater conveyance channels stablOfth channe .. ning a - or out protection? ❑ X❑ ❑ 13. Is in -stream construction conducted using measures to minimize channel dillblage? 0 ❑ ❑ 14. Are temporary stream crossings of non -erodible material installed where construction equipment ❑ ❑ crosses? 15. Are all DEQ water quality permit requ" ments being adhered to? ❑ 0 ❑ 16. Are material/equipment hand ling/storalk.areas clean and free of spills, leaks, or other deleterious ❑ ❑ materials and are related protective measures adequate?y 17. Is re -stabilization of in-str V struction complete before leaving the area? X❑ ❑ ❑ 18. Are utili o ches stabilized p e ly according to the specifications? ❑ X❑ ❑ 19. Is effluent from dewatering operations being filtered (including in -stream structure dewatering)? ❑ X❑ ❑ 20 Are construction entrances adequa protected, being maintained, and paved roadways kept clean from ❑ ❑ soil and mud? 21 s res that are no longer needed been removed and such areas been Have all temporary con lie X❑ El Elstabilized? 22 Are properties and waterw ys adjacent to development adequately protected from pollutant discharge, ❑ ❑ erosion, flooding, and sedimentation? Has encroachment outside of the project limits been prevented? 23. When necessary, are dust control measures being properly implemented? X❑ ❑ ❑ 24. Have all deficiencies from previous reports been addressed? ❑ ❑X ❑ 1—N/A: not applicable; 2— YES: All items related to contract requirements, plans, specifications, standards, and permits are being satisfied If a box is checked'NO' please seethe attached sheet for issue of non-compliance and corrective action necessary to regain VPDES compliance. This report was written by Joe Inspector 03/01/2017 Print Name Signature Date Sheet 1 of 2 VAR 10XXXX Project Name: New School/111222 VPDES EROSION CONTROL INSPECTION FORM "IF S9EE�:EE1:1:A:1:1 Wetland and $olutions, Ssudies lnc® -- a O�I1423 company Date: 03/01/2017 Item n (See sheet 1) Description of problem, location, and corrective action Date corrected/ Initials S Silt fence needs to be cleaned out and repaired when sediment reaches half the height of the barrier. 11 Inlet protection needs to be cleaned out and repaired when sediment reaches half the height of the barrier. 16 Concrete washout must be contained within an impervious area where it can cure and dry preventing wash from contaminating surrounding soil. 20 Sediment is being tracked onto roadway. Re -work construction entrance and sweep roadway as needed. * Continue to monitor and maintain all E&S controls for proper function. VSMP inspections occur every four business days, following the Commonwealth of Virginia holiday schedule. Weather Underground - Station Name (Station ID) - XXXft. Elev. I Lat., Long. Sheet 2 of 2 SWPPP Amendment & Modification Log Date Description of Amendment or Modification Responsible Party Signature per Part MK Operator or Delegated Authority Responsible Party Signature per Part 111 K Operator or Delegated Authority Responsible Party Signature per Part M K --------------------------------------------------------------- Operator or Delegated Authority Responsible Pa Signature per Part M K Operator or Delegated Authority Record of Land Disturbance The operator (or designee) shall update the SWPPP no later than seven days following any modification to its implementation. All modifications or updates to the SWPPP shall be noted and shall include the following items: 1. A record of dates when: a. Major grading activities occur; b. Construction activities temporarily or permanently cease on a portion of the site; and c. Stabilization measures are initiated; 2. Documentation of replaced or modified controls that have been used inappropriately or incorrectly and where modified as soon as possible; 3. Areas that have reached final stabilization and where no further SWPPP or inspection requirements apply; 4. All properties that are no longer under the legal control of the operator, and dates of which operator no longer had legal control; 5. The date of any prohibited discharges, the discharge volume released, and what actions were taken to minimize the impact of the release; 6. Measures taken to prevent the reoccurrence of any prohibited discharge; and 7. Measures taken to address any evidence identified as a result of an inspection required under Part II F. By initialing a SWPPP modification below, you are making the certification found in Part III K of the Permit. Action and Location Start Date / End Date initial Started mass clearing anrlgradiing in Section 1 of site. 7/1/14- 1011114 KG Insta!lerlperimetercontrolsinSections 1-S. 7/1/14 XG Started mass clearing andgrading in Section 3 of site. 8/13 4 2�G InstalledSediment rdasin #1 8/3/14 Construction activity clone in Section 1— temporary stabikZerl. N further inspections needed 4 IT Temporarily stabit'werlstockpile inTRE corner of site. /l4 DIF Section 7 of project transferredlegal contra! o . 1 1 10115114 f fplacedconcretewashout nearsite a' r. 11128114 RZ7f Instalherlperimetercontrohs ' ect ns -S 1/12/I5 IG Record of Land Disturbance The operator (or designee) shall update the SWPPP no later than seven days following any modification to its implementation. All modifications or updates to the SWPPP shall be noted and shall include the following items: t. A record of dates when: a. Major grading activities occur; b. Construction activities temporarily or permanently cease on a portion of the site; and c. Stabilization measures are initiated; 2. Documentation of replaced or modified controls that have been used inappropriately or incorrectly and where modified as soon as possible; 3. Areas that have reached final stabilization and where no further SWPPP or inspection requirements apply, 4. All properties that are no longer under the legal control of the operator, and dates of which operator no longer had legal control; 5. The date of any prohibited discharges, the discharge volume released, and what actions were taken to minimize the impact of the release; 6. Measures taken to prevent the reoccurrence of any prohibited discharge; and 7. Measures taken to address any evidence identified as a result of an inspection required under Part II F. By initialing a SWPPP modification below, you are making the certification found in Part III K of the Permit. Start Date Action and Location / Initials End Date Action and Location Start Date / Initial End Date LOT TAKE DOWN SHEET If temporary stabilization is utilized, the homebuilder shall provide a copy of the written notification and signed certification statement informing the homeowner of the need for, and benefits of, final stabilization; and that residence has been transferred to the homeowner (per Part 1 F.d of the Permit, and 9VAC25-880-1) Lot # Start Date Completion/ Stabilization Date Homebuilder Stabilization Measure M a M M --IConstruction 3 o iF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 LOT TAKE DOWN SHEET CONTINUED Lot # Construction Start Date Completion/ Stabilization Date Homebuilder Stabilization Measure V M m M m -.4 3 o 'm iF 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 LOT TAKE DOWN SHEET CONTINUED Lot # Construction Start Date Completion/ Stabilization Date Builder Stabilization Measure M m a m .1 3 o iE 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100