Loading...
HomeMy WebLinkAboutARB201400041 Plan - Approved 2014-03-25 (2)COPPER ROOF LINE OF EXISTING RIDGE IN HIP ROOF & VALLEY BEYOND REPLACE EXISTG REMOVE EXISTG STOREFRONT INSTALL NEW STORE FRONT FLAT ROOF OVER CUPOLA WITH RAISE CMU BASE WALL TO TO ALIGN W/ EXISTING NEW ADDITION NEW Ln ALIGN WITH LEFT SIDE & INSTALL ---. NEW STOREFRONT TO MATCH LEFT oo M 0 in o� I Ln I � � I REMOVE EXISTING CMU WALL & PATIO SLAB DOWN TO JUST BELOW SLAB - INSTALL NEW CMU W/ REINF ON TOP OF EXISTING ALIGN W/ EXIST ADJACENT WALLS SLOPE 1 " /FT m TOP OF FI]OOR I � I I I r I I-----------� NEW ADDITION NEW GLASS STOREFRONT ON TOP OF STUCCO FACED CMU WALL — ALIGN W EXISTING ADJACENT m FRONT ELEVATION (FACING ROUTE 2 50) SCALE; 1/8"" = 1 " -O"" EXTERIOR MATERIALS ALL NEW MATERIALS ARE TO MATCH EXISTING MATERIALS ROOF; SLATE GRAY ASPHALT SHINGLES WINDOWS; MEDIUM GRAY TINTED INSULATED GLASS IN ALUMINUM FRAMES WALLS; WHITE STUCCO ON CMU o s € co o tg 4w o_ J 0� r m Q Y W 2 cn U U r m z 3 o 02 r m Q � U 04 CV CV HOB LU Q C�J LU Z j co 0- m OL)o ��= O ��tU ff U z Ww oF- �w QF- cLF- oF- PROJ, NO.: 14 -03 DATE: 12 -12 -2014 SHEET NO. 1 LJ f� ❑ Pd FLAT ROOF OVER NEW ADDITION SLOPE 1 " /FT EXTEND EXISTING ROOF LINE OF EXISITNG HIP ROOF RIDGE & VALLEY BEYOND NEW FLAT ROOF NEW CUPOLA TO REPLACE EXISTING CUPOLA EXISTING OUTDOOR DINING PATIO TO BE ENCLOSED LEFT SIDE ELEVATION (FACING WEST) SCALE; 1/8 " = 1 " -0"" NEW FLAT ROOF OVERHANG EXISTING ROOF OVERHANG EXTERIOR MATERIALS EXISTING PATIO WALL REMOVE TOP COURSE OF CMU & INSTALL NEW SOLID CMU CAP TO ALIGN WITH EXISTING ADJACENT WALL ALL NEW MATERIALS ARE TO MATCH EXISTING MATERIALS ROOF; SLATE GRAY ASPHALT SHINGLES WINDOWS; MEDIUM GRAY TINTED INSULATED GLASS IN ALUMINUM FRAMES WALLS; WHITE STUCCO ON CMU o s € co o tg 4 w o_ J 0� r m Q Y � W 2 cn O U r m I I LONT NEW STO RE TO MATCH --:>i I I EXISTING OUTDOOR DINING PATIO TO BE ENCLOSED LEFT SIDE ELEVATION (FACING WEST) SCALE; 1/8 " = 1 " -0"" NEW FLAT ROOF OVERHANG EXISTING ROOF OVERHANG EXTERIOR MATERIALS EXISTING PATIO WALL REMOVE TOP COURSE OF CMU & INSTALL NEW SOLID CMU CAP TO ALIGN WITH EXISTING ADJACENT WALL ALL NEW MATERIALS ARE TO MATCH EXISTING MATERIALS ROOF; SLATE GRAY ASPHALT SHINGLES WINDOWS; MEDIUM GRAY TINTED INSULATED GLASS IN ALUMINUM FRAMES WALLS; WHITE STUCCO ON CMU o s € co o tg 4 w o_ J 0� Z CV Q < a °> cl) W Z j 0 c 0- :�i w o u �5 0- o< ��u J U z Ww �w oF- Q-J o 0:: � PROJ, NO.: 14 -03 DATE: 12 -12 -2014 SHEET NO. R2. r m Q Y � W 2 cn O U r m z 3 co o r m Q z c° od U Z CV Q < a °> cl) W Z j 0 c 0- :�i w o u �5 0- o< ��u J U z Ww �w oF- Q-J o 0:: � PROJ, NO.: 14 -03 DATE: 12 -12 -2014 SHEET NO. R2. EDGE C FLAT RC FACE O EXTERIO BELOW SCALE 3 / 16 - 1- O (ON 11 x 17 SHEET) FRONT (STREET SIDE) OF BUILDING TIP TOP RESTAURANT 12/12/2014