Loading...
HomeMy WebLinkAboutSP201300011 Staff Report 2013-04-16N J JRGOS ALBEMARLE COUNTY PLANNING STAFF REPORT SUMMARY Project Name: SP 201300011 Brochu Property- Verizon Staff: Brent Nelson, Planner Tier III PWSF Planning Commission Public Hearing: Board of Supervisors Hearing: June 4, 2013 July 10, 2013 Owners: Judith G. Brochu Applicant: Stephen Waller, GDN Sites; Lori H. Schweller, LeClairRyan Acreage: 21.10 acres Rezone from: Not applicable (Lease Area: 2,500 square feet) Special Use Permit for: 10.2.2(48) Special Use Permit, which allows for Tier III personal wireless facilities in the RA Zoning District. TMP: Tax Map 127 Parcel 40A By -right use: RA, Rural Areas Location: 3706 Irish Road Magisterial District: Samuel Miller Proffers /Conditions: No Requested # of Dwelling Units /Lots: N/A DA - RA - X Proposal: A ninety -five (95) foot Verizon treetop Comp. Plan Designation: Rural Area in Rural monopole and associated ground equipment Area 4. Character of Property: A moderately small, rural Use of Surrounding Properties: Rural Areas - property on the north side of Route 6 that is largely single family residential wooded and with one single - family home. Factors Favorable: Factors Unfavorable: 1. The monopole is located so that only the top 1. The proposal is located within the section of the monopole containing the Southern Albemarle Rural Historic District antennas is expected to be visible and only and within the Route 6 Entrance Corridor; through trees. however, the impact to these 2. The Architectural Review Board staff has resources is mitigated by the limited recommended approval based on minimal visibility of the site. visibility from Route 6, the Entrance Corridor. RECOMMENDATION: Staff recommends approval of SP 201300011 with conditions STAFF CONTACT: PLANNING COMMISSION: BOARD OF SUPERVISORS: AGENDA TITLE: PROPERTY OWNER: APPLICANT: Brent Nelson, Planner June 4, 2013 July 10, 2013 SP201300011: Brochu Property- Verizon Tier III Judith G. Brochu Verizon PROPOSAL: This is a proposal to install a Tier III personal wireless service treetop facility (Attachment A). The facility will contain a steel monopole that would be approximately 95 feet tall (10 feet AMSL above the height of the tallest tree within 25 feet), with associated ground equipment contained within a 2,500 square foot lease area. The property is 21.1 acres, described as Tax Map 127, Parcel 40A, located in the Samuel Miller Magisterial District and zoned RA, Rural Areas and EC, Entrance Corridor (Attachment B). The property is also located within the Southern Albemarle Rural Historic District. COMPREHENSIVE PLAN: The Comprehensive Plan designates the property as Rural Area in Rural Area 4. CHARACTER OF THE AREA: The proposed facility is to be located on a 2 1. 11 acre parcel located on the north side of Route 6, just east of the intersection with Route 717. The facility is to be situated approximately 567 ft. north of Route 6 in a wooded section of the parcel. There is an existing PWSF approximately 900 feet to the northeast on the adjoining parcel. The general character of the area is rural. The site is within the Southern Albemarle Rural Historic District, a National Register district. PLANNING AND ZONING HISTORY: SUB199400115: Family division, approved SP200800017: Request to construct an 92 ft. Tier III PWSF, withdrawn DISCUSSION: ANALYSIS OF THE SPECIAL USE PERMIT REQUEST: Section 33.8 of the Zoning Ordinance states that the planning commission and board of supervisors shall reasonably consider the following factors when reviewing and acting upon an application for a special use permit: No substantial detriment. The proposed use will not be a substantial detriment to adjacent lots. The property is located in the Southern Albemarle Rural Historic District. The Architectural Review Board staff person determined that the proposed location is expected to sufficiently minimize the visibility of the monopole from the Route 6 Entrance Corridor and historic sites in the vicinity (Attachment Q. It is staff's opinion that the proposal will not be of substantial detriment to the adjacent properties. The facility is located in a wooded area with ample 2 vegetation to screen the site (Attachment D). The monopole would only be visible through wooded areas where the trees are expected to significantly minimize its visibility Character of district unchan -aed. The character of the district will not be changed by the proposed special use. It is staff's opinion that the character of the zoning district will not change with this use. Harmony. The proposed special use will be in harmony with the purpose and intent of this chapter,... Staff has reviewed this request as it relates to the "purpose and intent" that is set forth in Sections 1.4.4 and 1.4.7 of the Zoning Ordinance, and as it relates to the intent specified in the Rural Areas chapter of the Zoning Ordinance (Section 10.1). This request is consistent with both sections. ...with the uses permitted by right in the district,... No significant adverse impacts on adjacent properties in the RA, Rural Area district are anticipated. The proposed personal wireless service facility will not restrict any nearby by- right uses within the Rural Areas district. Staff has not received any negative comments from citizens. ...with the regulations provided in section 5 as applicable, and with the public health, safety and general welfare. The public health, safety, and general welfare of the community is protected through the special use permit process, which assures that uses approved by special use permit are appropriate in the location requested. In this case, the proposed facility will give Verizon the ability to offer another choice of personal wireless service communication by providing a full range of voice and data services in addition to the required E911 call services. This can be seen as contributing to the public health, safety and welfare on a regional level. Compliance with Section 5 of the Zoning Ordinance is discussed in the following section of this report. Consistency with the Comprehensive Plan. The use will be consistent with the Comprehensive Plan. The supplementary regulations and design standards have been developed to provide consistency with the County's Comprehensive Plan and wireless Policy. Compliance with Section 5.1.40 of the Zoning Ordinance The county's specific design criteria for Tier III facilities as set forth in section 5.1.40 (e) are addressed as follows. Section 5.1.40 (e) Tier III. Each Tier III facility may be established upon approval of a special use permit by the board of supervisors, initiated upon an application satisfying the requirements of subsection 5.1.40(a) and section 33.4, and it shall be installed and operated in compliance with all applicable provisions of this chapter and the following: 1. The facility shall comply with applicable requirements subsections 5.1.40(b), the requirements of subsections 5.1.40(c)(2) through (8) and the requirements of subsections 5.1.40 (d)(2),(3) and (7), unless modified by the board of supervisors during special use permit review. 2. The facility shall comply with all conditions of approval of the special use permit. Requirements of subsection 5.1.40(a) application for approval and section 33.4 uniform procedures for owner- initiated zoning map amendments and special use permits have been met. Compliance with Section 5.1.40(e) of the Zoning Ordinance: The County's specific design criteria for Tier III facilities set forth in Section 5.1.40(e)(1) and 5.1.40(e)(2) are addressed as follows: [Ordinance sections are in italics] Subsection 5.1.40(8)(1 -5): Exemption from regulations otherwise applicable: Except as otherwise exempted in this paragraph, each facility shall be subject to all applicable regulations in this chapter. The proposed wireless facility will meet required Rural Areas setbacks in addition to all other area and bulk regulations and minimum yard requirements. The proposed 95 foot tall monopole is located approximately 169 feet from the nearest parcel line. Attached site drawings, antennae and equipment specifications have been provided to demonstrate that personal wireless service facilities (PWSF) regulations and any relevant site plan requirements set forth in Section 32 of the zoning ordinance have been addressed. Subsection 5.1.40(c)(2): General design. The facility shall be designed, installed and maintained as follows: (i) guy wires shall not be permitted; (ii) outdoor lighting for the facility shall be permitted only during maintenance periods; regardless of the lumens emitted, each outdoor luminaire shall be fully shielded as required by section 4.17 of this chapter; provided that these restrictions shall not apply to any outdoor lighting required by federal law; (iii) any equipment shelter not located within the existing structure or an existing building shall be screened from all lot lines either by terrain, existing structures, existing vegetation, or by added vegetation approved by the agent; (iv) a whip antenna less than six (6) inches in diameter may exceed the height of the existing structure or the existing building; (v) a grounding rod, whose height shall not exceed two (2) feet and whose width shall not exceed one (1) inch in diameter at the base and tapering to a point, may be installed at the top of the facility, the existing structure or the existing building; and (vi) within thirty (30) after completion of the installation of the facility, the applicant shall provide a statement to the agent certifying that the height of all components of the facility complies with this regulation. The proposed monopole does not require the installation of guy wires, nor will it be fitted with any whip antennas. The proposed grounding rod complies with the size requirements. Outdoor light fixtures will be shielded. All proposed lighting is for temporary maintenance and security use only. All associated ground equipment will be shielded from all lot lines by existing vegetation and terrain. Subsection 5.1.40(c)(3): Antennas and associated equipment. Antennas and associated equipment that are not entirely within a proposed facility, an existing facility, an existing structure, or an existing building shall be subject of the following: (i) the total number of arrays of antennas shall not exceed three (3), and each antenna proposed under the pending application shall not exceed the size shown on the application, which size shall not exceed one thousand one hundred fifty two (1152) square inches; (ii) no antenna shall project from the facility, structure or building beyond the minimum required by the mounting equipment, and in no case shall any point on the face of an antenna project more than twelve (12) inches from the facility, structure or building; and (iii) each antenna and associated equipment shall be a color that matches the existing facility, structure or building. For purposes of this section, all types of antennas and 2 dishes, regardless of their use, shall be counted toward the limit of three arrays. The proposed antennae configuration will consist of two arrays with three panel antennas. The antennas on one array will measure 94.6" x 11.2" x 4.5" while those on the other array will measure 47.4" x 16.8" x 3.5 ". Each antenna shall not exceed 1,152 square inches. These antennas will be installed using "pipe- mounts" that will allow for any required amount of down - tilting without exceeding the County's requirements for flush - mounts (12- inches maximum between the face of the monopole and the face of the antennae). All antennae will be painted to match the color of the tower. Subsection 5.1.40(c)(4): Tree conservation plan. Before the building official issuance of a building permit for the facility, the applicant shall submit a tree conservation plan prepared by a certified arborist. The plan shall be submitted to the agent for review and approval to enssure that all applicable requirements have been satisfied. The plan shall specify tree protection methods and procedures, identify all existing trees to be removed on the parcel for the installation, operation and maintenance of the facility, and shall identify all dead and dying trees that are recommended to be removed. In approving the plan, the agent may identify additional trees or lands up to two hundred (200) feet from the lease area to be included in the plan. The installation of the proposed personal wireless service facility will require the removal of some trees and the installation of an equipment shelter on concrete piers. The removal of the trees and installation of the steel platform does not affect the visibility or screening of the tower and associated equipment. Prior to the submittal of a building permit, the applicant will provide a tree conservation plan, prepared by a certified arborist, verifying that the proposed grading and installation of the equipment shelter will not adversely impact the survival of trees designated to remain. Subsection 5.1.40(c)(5) Tree conservation plan; compliance; amendment. The installation, operation and maintenance of the facility shall be conducted in accordance with the tree conservation plan. The applicant shall not remove existing trees within the lease area or within one hundred (100) feet in all directions surrounding the lease area of any part of the facility except for those trees identified on the plan to be removed for the installation, operation, and maintenance of the facility and dead and dying trees. Before the applicant removes any tree not designated for removal on the approved plan, the applicant shall submit and obtain approval of an amended plan. The agent may approve the amended plan if the proposed tree removal will not adversely affect the visibility of the facility from any location off of the parcel. The agent may impose reasonable conditions to ensure that the purposes of this paragraph are achieved. In order to ensure that there is no significant impact to any of the trees that are to remain, the conservation plan will be completed prior to the submittal of a building permit. Operation and maintenance of the facility will be conducted in accordance with the tree conservation plan. Subsection 5.1.40(0(6): Discontinuance of use; notice thereof; removal; surety. Within thirty (30) days after a facility's use for personal wireless service purposes is discontinued, the owner of the facility shall notify the zoning administrator in writing that the facility's use has discontinued. The facility shall be disassembled and removed from the site within ninety (90) days after the date its use for personal wireless service purposes is discontinued. If the agent determines at any time that surety is required to guarantee that the facility will be removed as required, the agent may require that the parcel owner or the owner of the facility submit a certified check, a bond with surety, or a letter of credit, in an amount sufficient for, and 5 conditioned upon, the removal of the facility. The type and form of the surety guarantee shall be to the satisfaction of the agent and the county attorney. In determining whether surety should be required, the agent shall consider the following: (i) whether there is a change in technology that makes it likely that the monopole or tower will be unnecessary in the near future; (ii) the permittee fails to comply with applicable regulations or conditions; (iii) the permittee fails to timely remove another monopole or tower within the county; and (iv) whenever otherwise deemed necessary by the agent. Should use of the tower site in this location become discontinued at anytime in the future, Verizon and/or its assignee(s) will be required to remove the facility within 90 days. Subsection 5.1.40(c)(7): Creation ofslopes steeper than 2:1. No slopes associated with the installation of the facility and its accessory uses shall be created that are steeper than 2:1 unless retaining walls, revetments, or other stabilization measures acceptable to the county engineer are employed. No slopes associated with the installation of the facility are steeper than 2:1. Subsection 5.1.40(c)(8): Ground equipment shelter; fencing. Any ground equipment shelter not located within an existing building shall be fenced only with the approval of the agent upon finding that the fence: (i) would protect the facility from trespass in areas of high volumes of vehicular or pedestrian traffic or, in the rural areas, to protect the facility from livestock or wildlife; (ii) would not be detrimental to the character of the area; and (iii) would not be detrimental to the public health, safety or general welfare. The proposal includes a 50'x 50' lease area that will be fenced with a 6 ft. tall wooden privacy fence and gate. Staff has found that this fence will not be detrimental to the character of the area, nor the public health, safety or general welfare and would protect the facility from wildlife. Section 5.1.40(d)(2): Screening and siting to minimize visibility. The site shall provide adequate opportunities for screening and the facility shall be sited to minimize its visibility from adjacent parcels and streets, regardless of their distance from the facility. The facility also shall be sited to minimize its visibility from any state scenic river, national park or national forest, regardless of whether the site is adjacent to the river, park or forest. If the facility would be located on lands subject to a conservation easement or an open space easement, or adjacent to a conservation easement or open space easement, the facility shall be sited so that it is not visible from any resources specifically identified for protection in the deed of easement. The proposed facility includes a monopole that would have a height of approximately 95 feet above ground level (AGL) or 769 feet above mean sea level (AMSL). The height of the reference tree is approximately 759 feet above mean sea level (AMSL) and is located within 25'of the proposed monopole. A balloon test was conducted on April 25, 2013 (Attachment E). During the site visit, staff observed a test balloon that was floated at the approximate height of the proposed monopole. Routes 6, 722, 717 and 715 were traveled to determine the extent of visibility of the proposal. The balloon was visible from Route 6, but only in the immediate vicinity of the property and only through trees. The balloon was also visible from one location along Route 722 but only through trees that minimized its visibility. There were no sustained views of the balloon above the trees. It is Staff's opinion that at the ten foot height, the low level of visibility is not expected 0 to have a negative impact on the Southern Albemarle Rural Historic District, the Route 6 Entrance Corridor or nearby historic properties. Section 5.1.40(d)(3): Open space resources. The facility shall not adversely impact resources identified in the county's open space plan. The County's wireless service facilities policy encourages facilities with limited visibility, facilities with adequate wooded backdrop, and facilities that do not adversely impact Avoidance Areas (including Entrance Corridors and historic resources). Staff's analysis of this request addresses the concern for the possible loss of aesthetic or historic resources. The proposed lease area is located within the Southern Albemarle Rural Historic District in the Open Space Plan (Attachment F). However, Architectural Review Board staff found that the facilities' limited visibility is not expected to have any adverse scenic impact. The Architectural Review Board staff has expressed no objection to the proposed site. . Therefore, staff feels the visibility of the monopole will not adversely impact the resources of the entrance corridor or those listed as avoidance areas. Section 5.1.40(d)(7): Color of monopole, antennas and equipment. Each monopole shall be a dark brown natural or painted wood color that blends into the surrounding trees. The antennas, supporting brackets, and all other equipment attached to the monopole shall be a color that closely matches that of the monopole. The ground equipment, the ground equipment shelter, and the concrete pad shall also be a color that closely matches that of the monopole, provided that the ground equipment and the concrete pad need not closely match the color of the monopole if they are enclosed within a ground equipment shelter or within or behind an approved structure, facade or fencing that: (i) is a color that closely matches that of the monopole; (ii) is consistent with the character of the area; and (iii) makes the ground equipment, ground equipment shelter, and the concrete pad invisible at any time of year from any other parcel or a public or private street. The applicant is proposing to install a steel monopole. The proposed color for the tower and associated ground equipment is Sherwin Williams Java Brown #6090 to match existing surroundings. There will also be an equipment shelter with a dark aggregate stone exterior. Section 5.1.40(e)2: The facility shall comply with all conditions of approval of the special use permit. The facility would comply with all conditions of approval of the special use permit (Section 33.8). Section 704(a)(7)(b)(I)(II) of The Telecommunications Act of 1996: This application is subject to the Telecommunications Act of 1996, which provides in part that the regulation of the placement, construction, and modification of personal wireless service facilities by any State or local government or instrumentality thereof (I) shall not unreasonably discriminate among providers of functionally equivalent services; (II) shall not prohibit or have the effect of prohibiting the provision of personal wireless services. 47 U.S. C. In order to operate this facility, the applicant is required to comply with the FCC guidelines for 7 radio frequency emissions that are intended to protect the public health and safety. Neither the Comprehensive Plan nor the Zoning Ordinance prohibits the provision of personal wireless services. However, both do implement specific policies and regulations for the sighting and design of wireless facilities. In its current state, the existing facilities and their mounting structure all offer adequate support for providing personal wireless communication services. The applicant has not provided any additional information regarding the availability, or absence of alternative sites that could serve the same areas that would be covered with the proposed antenna additions at this site. Therefore, staff does not believe that the special use permitting process nor the denial of this application would have the effect of prohibiting or restricting the provision of personal wireless services. SUMMARY: Staff has identified factors which are favorable and unfavorable to this proposal: Factors favorable to this request include: 1. The monopole is located so that only the top section of the monopole containing the antennas is expected to be visible and only through trees. 2. The Architectural Review Board staff has advised that there would be minimal visibility from Route 6, the Entrance Corridor. 3. There is limited visibility of the tower from nearby historic sites /district and conservation easement properties and nearby public roads and properties. Factors unfavorable to this request include: 1. The proposal is within the Southern Albemarle Rural Historic District and located within the Route 6 Entrance Corridor; however, the impact to these resources is mitigated by the limited visibility of the site. In order to comply with Section 5.1.40(d) of the Zoning Ordinance, the Planning Commission is required to provide the applicant with a statement regarding the basis for denial and all items that will have to be addressed to satisfy each requirement. RECOMMENDATION: Staff recommends approval of this facility at ten (10) feet above the tallest tree with the conditions outlined below. Conditions of approval: Development and use shall be in general accord with the conceptual plan titled "Boiling Siding (Orrock Property) 3706 Irish Road, Esmont, VA22937" prepared by Justin Y. Yoon latest revision date 5/15/13 (hereafter "Conceptual Plan "), as determined by the Director of Planning and the Zoning Administrator. To be in general accord with the Conceptual Plan, development and use shall reflect the following major elements within the development essential to the design of the development, as shown on the Conceptual Plan.: a. Height b. Distance above reference tree Minor modifications to the plan which do not conflict with the elements above may be made to ensure compliance with the Zoning Ordinance. ATTACHMENTS: A. Site Plan B. Vicinity C. Architectural Review Board Staff Comments D. Site Photos E. Balloon Test F. Open Space & Critical Resource Map Motion: The Planning Commission's role in this case (SP201300011) is to make a recommendation to the Board of Supervisors. A. Should the Planning Commission choose to recommend approval of this Tier III personal wireless service facility I move to recommend approval of SP 201300011 Brochu Property Verizon Tier III PWSF with the conditions outlined in the staff report. B. Should the Planning Commission choose to recommend denial of this Tier III personal wireless service facility: I move to recommend denial of SP 201300011 Brochu Property Verizon Tier III PWSF. (Planning Commission needs to give reasons for denial) 9 E S — d VOOOO� veriZon wireless DIRECTIONS TO SITE: FROM 1831 RADY COURT: TAKE 1 -64 WEST APPROXAMATELY 70.1 MILES TO EXIT 121 AND TURN RIGHT ON RAMP THEN TURN LEFT ONTO SR -20 SOUTH FOR APPROXAMATELY 12 MILES. TURN RIGHT INTO DRIVEWAY AT 7240. FOLLOW GRAVEL ROAD BACK TO THE REAR OF THE PROPERTY TO THE SITE ON THE LEFT. TURN RIGHT ONTO C.R. 712 /PLANK ROAD. KEEP LEFT AT THE FORK AND CONTINUE TO C.R. 715 /ESMONT ROAD. TURN RIGHT ONTO VA- 6W /C.R. 715 /IRISH ROAD. DESTINATION OF 3706 IRISH ROAD WILL BE ON THE RIGHT. TURN INTO GRAVEL DRIVE AND ARRIVE AT OUR SITE LOCATED ON THE RIGHT. I Oanxio OIU ' Pomininn �� PROJECT SITE ,ill­ LOCAL MAP NOT TO SCALE PROJECT SITE r S,P p06 6� u�i SchuY k, VICINITY MAP NOT TO SCALE North North BOILING SIDING BROCHU PROPERTY 3706 IRISH ROAD ESMONT, VA 22937 PROJECT DESCRIPTION INSTALLATION OF MONOPOLE, COMPOUND AND OPERATION OF ANTENNAS AND BASE STATION EQUIPMENT IN A RAW -LAND LEASE AREA UTILITIES INFORMATION: 2 WORKING DAYS POWER: CENTRAL VIRGINIA ELECTRIC BEFORE YOU DIG COOPERATIVE (CVEC) 811 CUSTOMER SERVICE: 1- 800 - 367 -2832 TOLL FREE TELEPHONE: CENTURY LINK MISS UTILITY CUSTOMER SERVICE: 1- 800 - 769 -0110 APPROVAL ACQUISMON MANAGER: SIGNATURE PHONE NUMBER DATE CONSTRUCTION MANAGER: SIGNATURE PHONE NUMBER DATE RF ENGINEERING: SIGNATURE PHONE NUMBER. DATE NETWORK OPS MANAGER: SIGNATURE PHONE NUMBER DATE BOILING SIDING BROCHU, JOSEPH EUGENE 3706 IRISH ROAD REV. NO. DESCRIPTION ENSITE PLAN BY SPP DATE 08/30/12 REV. NO. DESCRIPTION BY DATE REVIEW SET JYY 09/11/12 OAPPLICATION DRAWINGS JYY 04/12/13 4 REVISED APPLICATION DRAWINGS JYY 05/15/13 RICHMOND, VA 23222 ALAN GUMMO CONTACT: CONSULTING TEAM ARCHITECTURE AND ENGINEERING: CLARK NEXSEN 1331 L STREET NW, SUITE 600 WASHINGTON, DC 20005 PROJECT MANAGER: STUART PATTERSON, PE TELEPHONE: (202) 461 -3287 FAX NUMBER: (202) 461 -3266 SURVEY: CAUSEWAY CONSULTANTS, PC P.O. BOX 15039 CHESAPEAKE, VA 23328 CONTACT: ROBERT T. WILLIAMS,JR, L.S. TELEPHONE: (757) 482 -0474 STRUCTURAL ENGINEERING: CLARK NEXSEN 6160 KEMPSVILLE CIRCLE SUITE 200A NORFOLK, VA 23502 CONTACT: SHANE FOWLER, PE TELEPHONE: (757) 455 -5800 FAX NUMBER: (757) 455 -5800 ELECTRICAL ENGINEERING: CLARK NEXSEN 440 MARTIN LUTHER KING Jr #101 MACON, GA 31201 CONTACT: HAROLD BELYEU, PE TELEPHONE: (478) 743 -8415 FAX NUMBER: (478) 743 -8239 GEOTECHNICAL ENGINEERING: GEOENVIRONMENTAL RESOURCES, INC. 2712 SOUTHERN BOULEVARD, SUITE 101 VIRGINIA BEACH, VA 23452 CONTACT: CHAZ CRAWLEY, PE TELEPHONE: (757) 463 -3200 FAX NUMBER: (757) 463 -3080 PROJECT SUMMARY SITE INFORMATION: PROPERTY OWNER: BOILING SIDING BROCHU, JOSEPH EUGENE 3706 IRISH ROAD OR BARBARA S ESMONT, VA 22937 3668 IRISH ROAD 3036.108 ESMONT, VA 22937 APPLICANT INFORMATION: SYM. VERIZON WIRELESS 1831 RADY COURT RICHMOND, VA 23222 ALAN GUMMO CONTACT: (757) 681 -1505 TELEPHONE: (804) 321 -0398 FAX NUMBER: PROJECT DATA ZONING RA, EC JURISDICTION ALBEMARLE COUNTY MAGISTERIAL DISTRICT SCOTTSVILLE PARCEL ID # 127000000040A0 SITE TYPE RAWLAND TOWER TYPE MONOPOLE TOWER HEIGHT 95.0' LEASE AREA 2,500 SF AREA OF LAND DISTURBANCE 4,000 SF (2C) GEOGRAPHIC COORDINATES: LATITUDE: 37 49' 48.1270" N (NAD 83) LONGITUDE: 78' 38' 02.3003" W (NAD 83) GROUND ELEVATION (AMSL): 674.2' t (NAVD 88) ADA COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. SITE WILL NOT BE SERVED BY CITY SEWER OR WATER. Sheet Number GENERAL G -1 CIVIL C -1 C -1A C -1B C -2 C -2A C -3 C -4 LANDSCAPE L -1 L -2 ARCHITECTURAL A -1 Sheet Title COVER SHEET SITE PLAN TREE INVENTORY AREA MAP ENLARGED SITE PLAN GRADING PLAN ELEVATION VIEW DETAILS LANDSCAPE PLAN LANDSCAPING DETAILS SHEET TOTAL: 11 ,cure & Engineer 1331 L STREET, SUITE WASHINGTON, DC 2[ 202+61.3260 FAX 202.461 veriZon wireless 1831 RADY COURT RICHMOND, VA 23222 oJiJST YOON Lie. No. 42897 1 ONAL SITE INFO.: BOILING SIDING RAWLAND 3706 IRISH ROAD ESMONT, VA 22937 ALBEMARLE COUNTY DESIGN: JYY DRAWN: KAW REVIEW: SPP TrV DATE: 12/05/07 COMM. NO. 3036.108 SUBMITTALS SYM. DESCRIPTION DATE ENSITE PLAN 08/30/12 REVIEW SET 09/11/12 APPLICATION DRAWINGS 04/12/13 � /a\ REVYSED APPLICATION DWGS 0-9/15/13 SHEET NAME: COVER SHEET SHEET NO.: G -1 F S E I 3 i v i n i ABBREVIATIONS 0, DIA DIAMETER ADJACENT TO A COUNTY DESIGNATED NUMBER A/C AIR CONDITIONING ADA AMERICANS WITH DISABILITIES ACT AFG ABOVE FINISHED GRADE AGL ABOVE GROUND LEVEL ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS C, C/L CENTERLINE CONIC CONCRETE D.B. DEED BOOK DWG(S) DRAWINGS ELEV ELEVATION ENODE B RF CABINET EDE EXISTING OVERHEAD ELECTRIC EZBFO BATTERY BACKUP CABINET (F) FOUND FFE FINISHED FLOOR ELEVATION FIRM FLOOD INSURANCE RATE MAP GIs GEOGRAPHIC INFORMATION SYSTEM GPIN GRID PARCEL IDENTIFICATION NUMBER GPS GLOBAL POSITIONING SYSTEM ID IDENTIFICATION INC INCORPORATED INV INVERT INFO INFORMATION L/P LIGHT POLE /LAMP POST LLC LIMITED LIABILITY CORPORATION LS LAND SURVEYOR LTE LONG TERM EVOLUTION MAX MAXIMUM MHz MEGAHERTZ MIN MINIMUM N NORTH NW NORTHWEST NAD NORTH AMERICAN DATUM NAVD NORTH AMERICAN VERTICAL DATUM NO NUMBER OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION P/P POWER POLE P.B. PLAT BOOK PE PROFESSIONAL ENGINEER PG. PAGE PROJ. PROJECT SCH SCHEDULE SF SQUARE FOOT/FEET STD STANDARD TTV TECHNICAL TEAM VISIT TYP TYPICAL VDOT VIRGINIA DEPARTMENT OF TRANSPORTATION W WEST N85'54'35"W i 59.aa SIGHT DISTANCE 425'± L`4, R,1195. J9 THIS SITE IS NOT LOCATED WITHIN OR JYY ADJACENT TO A COUNTY DESIGNATED EXISTING CONSERVATION EASEMENT. SPP THIS SITE IS NOT LOCATED WITHIN ANY COMM. NO. 3036.108 AREA DESIGNATED AS AN AGRICULTURAL - -- OR FORESTAL DISTRICT. j / T.M.P. 119 -56C QUINTAIN, LLC DB 2704 -498 DB 1887 -113 PLAT / ZONED: RA LAND USE: RESIDENTIAL b T.M.P. 127 -40A2 SEE ENLARGED SITEy %h JUDITH G. BROCHU' PLAN, SHEET C -2 2.0o ACRES � 'J2\ LAND OED:- RA yy�yoy� RESIDENTIAL FALL ZONE RADIUS J2 s i i � � r / N i .4, a� �11. i T.M.P. 127 -40A RX / RXR SPIKE JUDITH c. eROCHU. � ELEV= 676.06 D.B. 1459/PG.735 ' ZONED: RA ° RA LAND USE: RESIDENTIAL i / LOT 2 / T.M.P. 127-40A1 JOSE E. and BARBARA BROCHU r DB 1458 -735 SIGHT DISTANCE DB 1459 -733 PLAT I EXCEEDS 610'± 16.32 ACRES \ i ZONED: RA J ' LAND USE RESIDENTIAL T.M.P. 127-40132 II / BROCHU, JOYCE E 2.74 ACRES ZONED: RA LAND USE: RESIDENTIAL T.M.P. 127-40G BROCHU, JOYCE WOO OODSON �. -- 6.22 ACRES ZONED: RA LOT LAND USE: RESIDENTIAL ' T.M.P. 127 -4066 \ / LIBERTY HOMES IN D 1 3174 -667 �\ DB 3169 -572 PLAT \ 4.29 ACRES 1 /JOSEPH E. OR BARBARA BROCHU DB 656-497, D6.644 -476 PLAT TM 127 -40E /r SURVEY NOTES ` 1. TOPOGRAPHIC INFORMATION WAS TAKEN FROM A TOPOGRAPHIC rchitecture & Engineering SURVEY PERFORMED BY CAUSEWAY CONSULTANTS, P.C., 1331 LSTREET, NVV CHESAPEAKE, VIRGINIA ON 12/05/07. METES AND BOUNDS WERE SUITE 600 COMPILED FROM PLATS AND /OR DEEDS OF RECORD. NO WASHINGTON, DC 20005 BOUNDARY SURVEY WAS PERFORMED BY CAUSEWAY CONSULTANTS, P.C. 202.4613260 FAX202.461.3266 W WW.CLARn4EXSEN.COM 2. PROPERTY IS SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF RECORD. 3. FLOOD ZONE DETERMINATION IS BASED ON THE FLOOD INSURANCE RATE MAPS AND DOES NOT IMPLY THAT THE PROPERTY WILL OR WILL NOT BE FREE FROM FLOODING OR DAMAGE. veriVn wireless 4. THIS SITE APPEARS TO BE LOCATED IN THE F.I.R.M. ZONE "X" AS SHOWN ON COMMUNITY PANEL NUMBER 51003CO500D EFFECTIVE 1831 RADY COURT DATE 2/04/05. RICHMOND, VA 23222 5. NO SUBSURFACE INVESTIGATION WAS PERFORMED BY CAUSEWAY CONSULTANTS, P.C. 6. MERIDIAN SOURCE FOR THIS SURVEY IS BASED UPON GRID NORTH. Vly H OP MAGNETIC DECLINATION IS COMPUTED AND NOT OBSERVED. ��' hf 7. NO WETLAND AREAS HAVE BEEN DELINEATED. 8. ALL PHYSICAL EVIDENCE OF UTILITIES SHOWN ON THIS SURVEY IS FROM SURFACE EVIDENCE. O JUSTIN Y, YOON" 9. THE TEMPORARY BENCHMARK, ELEVATION = 678.06'. 7 y Lic. No. 42897 ® CONSTRUCTION NOTES NAL 1. NEW VERIZON WIRELESS MONOPOLE, SEE ELEVATION VIEW ON SHEET C -3 SITE INFO.: ® LEASE NOTES BOILING SIDING RAWLAND 1. NEW VERIZON WIRELESS 50' X 50' LEASE AREA 2. NEW VERIZON WIRELESS NON- EXCLUSIVE 20' WIDE INGRESS /EGRESS /UTILITY EASEMENT LEGEND JYY DRAWN: EXISTING NEW SPP coNC COMM. NO. 3036.108 CONCRETE - -- IYM. PROPERTY LINE — — — LEASE AREA 08/30/12 EASEMENT I® BUILDING (FOOTPRINT) * ❑ FENCE EOE --- _786__ -- I --786— GRAPHIC SCALE(S) TREELINE EDGE OF PAVEMENT EDGE OF GRAVEL OVERHEAD ELECTRIC CONTOURS MONOPOLE POWER POLE TREE TO BE REMOVED FOR 22" X 34" PLOT - 1" = 100' 0 100' 200' FOR 11" X 17" PLOT - 1" = 200' NMI 3706 IRISH ROAD ESMONT, VA 22937 ALBEMARLE COUNTY DESIGN: JYY DRAWN: KAW SEW SPP TTV DATE: 12/05/07 COMM. NO. 3036.108 SUBMITTALS IYM. DESCRIPTION DATE ENSITE PLAN 08/30/12 REVIEW SET 09/11/12 L PPUCATION DRAWINGS 04/12/13 REVISED APPLICATION DWGS 05/15/13 SHEET NAME: SITE PLAN SHEET NO.: C -1 18" PINE (172) II 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 'il-\ i 50' RA01U5 CENTER OF TOWER I I I 1 I EXISTING �GRAVL -L ROAD \ I / \ I � I � � II / *2" OAK (206) \ I *4" OAK (205) \ *4" OAK (204) 1 1 *6' PINE (209) *4 " AK (212) I *4 ° OAK (202) 22" POP 07) _ _ _ _ , _ *3 OAK FLUSTER (21'1) II II It REFERENC REE 1 F4" bAK (184) *2t " OA (2 10) I I I I I �— —� 110" PINE (213) I *4 "IOAyf (183) -- - -- — I 11 II � *4" K (1$2) *4' OAK (181) I I I II i I V 14" OAK (1 1� OAK (178) * 0 OA (176) *6�OAK (185) AK GLUI�SER(187 10" OAK I II I � I II I I I I I I ase� II II � 12" OAK (174) TRY RXR SPIKE ELE1=678.06 I I I 12" PINE (215) I 14" PINE (217) 22" PINE (219) 12" PINE (197) *8" OAK (199) *8° TWIN OAK (200) 10° PINE (191) 18° PINE (193) 14" OAK (195) NOTE — ALL UTILITY LINES ARE PROPOSED TO BE RUN UNDERGROUND WITHIN THE UTILITY AND ACCESS EASEMENT SHOWN ON THE PLAN AND INDICATED ABOVE IN LEASE NOTE #2. FINAL LOCATION OF UTILITY LINES WILL BE DETERMINED BY THE COMPANIES PROVIDING ELECTRICAL AND TELEPHONE SERVICES. EXTREME CARE SHALL BE TAKEN NOT TO DAMAGE EXISTING TREES THAT ARE TO REMAIN. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACEMENT OR COMPENSATION OF DAMAGED TREES. NOTE — SITE SHALL BE MAINTAINED IN ACCORDANCE WITH A TREE CONSERVATION PLAN TO BE PREPARED BY A CERTIFIED ARBORIST, AS REQUIRED BE SEC. 5.1.40(C)(4). ® CONSTRUCTION NOTES 1. NEW VERIZON WIRELESS MONOPOLE, SEE ELEVATION VIEW ON SHEET C -3 ® LEASE NOTES 1. NEW VERIZON WIRELESS 50' X 50' LEASE AREA 2. NEW VERIZON WIRELESS NON— EXCLUSIVE 20' WIDE INGRESS /EGRESS /UTILITY EASEMENT TREE INVENTORY NUMBER SPECIES CALIPER CANOPY HEIGHT (172) PINE 18" 739' AMSL (174) OAK 12" 740' AMSL *(176) OAK 10" 735' AMSL *(178) OAK 10" 739' AMSL *(180) OAK 8" —' AMSL *(181) OAK 4" —' AMSL *(182) OAK 8" —' AMSL *(183) OAK 4" —' AMSL *(184) OAK 4" —' AMSL *(185) OAK 6" 737' AMSL (187) 5 OAK CLST 36" 748' AMSL (189) TWIN OAK 10" 735' AMSL (191) PINE 10" 735' AMSL (193) PINE 18" 737' AMSL (195) OAK 14" 749' AMSL (197) PINE 12" 725' AMSL *(199) OAK 8" —' AMSL *(200) TWIN OAK 8" —' AMSL *(201) OAK 6" —' AMSL *(202) OAK 4" —' AMSL *(204) OAK 4" —' AMSL ( *205) OAK 4" —' AMSL *(206) OAK 2" —' AMSL (207) POPLAR 22' 759' AMSL *(209) PINE 4" —' AMSL *(210) OAK 2" —' AMSL *(211) 3 OAK CLST 16" —' AMSL *(212) OAK 4" —' AMSL (213) PINE 10" 723' AMSL (215) PINE 12" 727' AMSL (217) PINE 14" 726' AMSL (219) PINE 22" 735' AMSL *TOTAL TREES TO BE REMOVED: 19 NOTE: REFERENCE TREE IS IDENTIFIED ABOVE IN BOLD NOTE: TREE DRIPUNES ARE DRAWN TO SCALE. GRAPHIC SCALE(S) AGL HEIGHT 59' 64' 58' 62' -ture & Engineer 1331 L STREET, SUITE WASHINGTON, DC 2C 202461.3260 FAX 202.461 veriLon wireless 1831 RADY COURT RICHMOND, VA 23222 01 r's�' J UST iY00� N Lie. No. 42897 /V3 Ww w ���SI ONAL FOR 22" X 34" PLOT — 1" = 10' 0 5' 10' 20' FOR 11" X 17" PLOT — 1" = 20' SHEErNO.: C -1 A STE INFO.: BOILING SIDING RAWLAND 3706 IRISH ROAD ESMONT, VA 22937 ALBEMARLE COUNTY - - - 62' 71' 61' 62' 63' 75' 54' - REVISED APPLICATON DWGS _ DESIGN: — — DRAWN: REVIEW: — _ TTV DATE-- 12/05/07 COMM. NO. 3036.108 FOR 22" X 34" PLOT — 1" = 10' 0 5' 10' 20' FOR 11" X 17" PLOT — 1" = 20' SHEErNO.: C -1 A SYM. DESCRIPTION 83' ENSNE PLAN _ z REVIEW SEf s kPPUCATION DRAWINGS i REVISED APPLICATON DWGS — 54' 58' SHEETNMIE: TREE INVEN 58 69' FOR 22" X 34" PLOT — 1" = 10' 0 5' 10' 20' FOR 11" X 17" PLOT — 1" = 20' SHEErNO.: C -1 A E ® NOTES DISCIIFIMN ' 1. CL OF TOWER rchitecture & Engineers N: 3825808.66 z REVIEW SEf E: 11444222.65 a 1331 L STREET, P 4 /12/13 A SUITE , LATITUDE: 3T 49' 48.1270" N (NAD 83) WASHINGTON, DC 20 LONGITUDE: 78' 38' 02.3003 W (NAD 83) 202. 461.3260 FAX202.461.3 ELEVATION: 674.20± (NAVD 88) WWW.CLARKNEXSEN.0 2. 2000' RADIUS FROM q OF TOWER 3. EXISTING DWELLING, TYP, veriLon wireless 1831 RADY COURT RICHMOND, VA 23222 GRAPHIC SCALE(S) FOR 22' X 34' PLOT - 1' = 300' 0 300' 600' FOR 11' X 17" PLOT - 1' = 600' OF o � J[IS�00�� ✓�. Lic. No. 42897 •�� /�s /i3 �ww NA SITE INFO.: BOILING SIDING RAWLAN D 3706 IRISH ROAD ESMONT, VA 22937 ALBEMARLE COUNTY SY14.1 DISCIIFIMN DATE i ENSUE PLAN 8 /30/12 z REVIEW SEf 09/11/12 1,1,05/15/131 a PUCATION DRAWINGS 4 /12/13 A REVISED APPLICATION DWGS %ffr NMS AREA MAP SHEET NO.: C-lB E II I I I I I I I I I I I I I I I I I I I I I Exisrnvc GRAVEL ROAD I EXISTING 22" POPLAR REFERENCE TREE I I I I I I I i I I C I I I - -� 8 I I I 0 r RRO I J _ I/ I� I I I I I I I OPERATION OF OUTDOOR LIGHTING FOR THE FACILITY SHALL BE PERMITTED ONLY DURING MAINTENANCE PERIODS. IF- — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — ' — ­I 1 1 28.5' L.-.-._ ._._._._._._._._._._._.- . -. -. -. NOTES 1. PRIOR TO CONSTRUCTION THE CONTRACTOR SHALL ASSUME THE RESPONSIBILITY OF LOCATING ANY UNDERGROUND UTILITIES (PUBLIC OR PRIVATE) THAT MAY EXIST AND CROSS THROUGH THE AREA OF CONSTRUCTION THAT ARE NOT SHOWN ON THESE PLANS. BEFORE YOU DIG, CALL "MISS UTILITY" AT 811. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING, AT HIS EXPENSE, ANY EXISTING UTILITIES DAMAGED DURING CONSTRUCTION. 2. ALL EROSION AND SEDIMENT CONTROL DEVICES SHALL BE INSTALLED BY CONTRACTOR IN ACCORDANCE WITH THE LATEST EDITION OF VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK BEFORE LAND DISTURBANCE COMMENCEMENT AND CHECKED PERIODICALLY TO ENSURE THEY ARE FUNCTIONING AS INDICATED. 3. THE STOCKPILING OF EXCESS MATERIAL ON SITE WILL NOT BE ALLOWED. 4. ANY VEGETATED AREA DISTURBED BY CONSTRUCTION SHALL BE THE RESPONSIBILITY OF CONTRACTOR TO SEED AND ESTABLISH A PERMANENT VEGETATIVE COVER. 5. THE CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION. SAFETY IS THE RESPONSIBILITY OF THE CONTRACTOR. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH OSHA REQUIREMENTS. 6. THE CONTRACTOR IS RESPONSIBLE FOR SITE LAYOUT AND CONSTRUCTION STAKING. LOCATION OF EXISTING STRUCTURES AND UTILITIES MUST BE CONFIRMED BY THE CONTRACTOR. 7. ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL CODES OR ORDINANCES. 8. THE INDICATED DIRECTION OF NORTH WILL HAVE TO BE VERIFIED IN THE FIELD. ® CONSTRUCTION NOTES 1. NEW 12' X 20' VERIZON WIRELESS EQUIPMENT SHELTER (MIRRORED) 2. NEW VERIZON WIRELESS 4' X 4' CONCRETE STOOP 3. NEW VERIZON WIRELESS CONCRETE PIERS 4. NEW VERIZON WIRELESS ICE BRIDGE 5. NEW VERIZON WIRELESS MONOPOLE TOWER 6. NEW VERIZON WIRELESS WOOD FENCE 7. NEW VERIZON WIRELESS GENERATOR ON 4' X 8' CONCRETE PAD 8. NEW VERIZON WIRELESS 12' WIDE GRAVEL ACCESS ROAD. 9. LIMITS OF NEW GRAVEL 10. NEW VERIZON WIRELESS METER & DISCONNECT 11. NEW CENTURY LINK FIBER CABINET ON UTILITY FRAME ® LEASE NOTES 1. NEW VERIZON WIRELESS 50' X 50' LEASE AREA 2. NEW VERIZON WIRELESS NON- EXCLUSIVE 20' WIDE INGRESS /EGRESS /UTILITY EASEMENT GRAPHIC SCALE(S) FOR 22" X 34' PLOT - 1" = 5' 0 5' 10' FOR 11" X 17" PLOT - 1" = 10' -tore & Engineer 1331 L STREET, SUITE WASHINGTON, DC 2C 202461.3260 FAX 202.461 veriM wireless 1831 RADY COURT RICHMOND, VA 23222 4 J UST Y0ON Lie. No. 42897 w ti ���SI0NAL SITE INFO.: BOILING SIDING RAWLAND 3706 IRISH ROAD ESMONT, VA 22937 ALBEMARLE COUNTY JYY KAW M.1 DESCRIFMN I DATE i ENSILE PLAN 8/30/12 z REVIEW SEr 09/11/12 1,1,05/15/131 s PLICATION DRAWINGS 4 /12/13 A REVISED APPLICATION DWGS %HET NAME ENLARGED SITE PLAN SHWr NO.: C -2 E S 3 I a 0 I, jl �I I I I I I I I I I I I I I EwsnNC GRAVEL ROAD I 11 II 'I I II I I I '1 I II it II I I I, I �I I I I i I �\ I = � I I. I I a I I I I I� I I I I CC I 1 I - I k r IR E I 0 C i 'I / ' I I � I i I I T � l i i i i I I / I ® CONSTRUCTION NOTES THERE ARE NO CRITICAL SLOPES WITHIN 1. NEW VERIZON WIRELESS 12' WIDE GRAVEL ACCESS ROAD. , THE PROJECT AREA. 2. NEW TREE PROTECTION. SEE DETAIL ON SHEET L -2. I GRADING NOTES 1. ALL ELEVATIONS ARE FINISHED GRADE. I DATE I I I � I � 2. ENSURE POSITIVE DRAINAGE FROM SITE AT ALL TIMES. z � I I li I �I ,I ACCESS ROAD. USE TYPAR 3401 OR EQUIVALENT. PUCATION DRAWINGS 04 /12/13 y�. �I I j � I I I I i I I E & S CONTROL LEGEND 1 II I I TP— TREE PROTECTION PS PERMANENT SEEDING 0 C i 'I / ' I I � I i I I T � l i i i i I I / I ® CONSTRUCTION NOTES THERE ARE NO CRITICAL SLOPES WITHIN 1. NEW VERIZON WIRELESS 12' WIDE GRAVEL ACCESS ROAD. , THE PROJECT AREA. 2. NEW TREE PROTECTION. SEE DETAIL ON SHEET L -2. I GRADING NOTES I� I I II 0 III I � II I ' ;I I' 671.00 I ' I i i I i I I I I %r i I � I I I I ; I I I I I r I i j I I I 1 I I I GRAPHIC SCALE(S) FOR 22' X 34' PLOT - 1' = 5' 0 5' 10' FOR 11' X 17' PLOT - 1' = 10' -tore & Engineer 1331 L STREET, SUITE WASHINGTON, DC 2C 202461.3260 FAX 202.461 veriM wireless 1831 RADY COURT RICHMOND, VA 23222 01 JU TIN YOON Lie. No. 42897 k�3 �"17 w ti ONAL ��W �I SIM INM.: BOILING SIDING RAWLAND 3706 IRISH ROAD ESMONT, VA 22937 ALBEMARLE COUNTY M.1 1. ALL ELEVATIONS ARE FINISHED GRADE. I DATE I ENSNE PLAN 2. ENSURE POSITIVE DRAINAGE FROM SITE AT ALL TIMES. z 3. PLACE GEOTEXTILE FILTER UNDER COMPOUND AND GRAVEL 09/11/12 ACCESS ROAD. USE TYPAR 3401 OR EQUIVALENT. PUCATION DRAWINGS 04 /12/13 A j � I I I I i I I E & S CONTROL LEGEND j TP— TREE PROTECTION PS PERMANENT SEEDING f LIMITS OF DISTURBANCE I� I I II 0 III I � II I ' ;I I' 671.00 I ' I i i I i I I I I %r i I � I I I I ; I I I I I r I i j I I I 1 I I I GRAPHIC SCALE(S) FOR 22' X 34' PLOT - 1' = 5' 0 5' 10' FOR 11' X 17' PLOT - 1' = 10' -tore & Engineer 1331 L STREET, SUITE WASHINGTON, DC 2C 202461.3260 FAX 202.461 veriM wireless 1831 RADY COURT RICHMOND, VA 23222 01 JU TIN YOON Lie. No. 42897 k�3 �"17 w ti ONAL ��W �I SIM INM.: BOILING SIDING RAWLAND 3706 IRISH ROAD ESMONT, VA 22937 ALBEMARLE COUNTY M.1 DBCRIFMN I DATE I ENSNE PLAN 08/30/12 z REVIEW SEf 09/11/12 s PUCATION DRAWINGS 04 /12/13 A REVISED APPLICAn0N DWGS 05/15/13 SHIE PW` E GRADING PLAN ISHW c -2a 8 j —TOP OF TOWER APPURTENANCES (LIGHTING ROD) Y ELEVATION = [771.0'±] AMSL [97' -0"] A.G.L. TOP OF TOWER / TOP OF ANTENNAS ELEVATION = [769.0'1] AMSL [95' -0' A.G.L. - - - - - - — 0 0 REFERENCE TREE IDENTIFIED AS 22" POPLAR /T TOP OF CANOPY ELEVATION = [759' -O " ±] AMSL OIL HEIGHT = 759' AMSL. l I NOTE: FENCE NOT SHOWN FOR CLARITY Li ZQ a REFERENCE TREE NEW VERIZON WIRELESS ICE BRIDGE NEW VERIZON WIRELESS 12'x20' EQUIPMENT SHELTER - TOWER FOUNDATION DESIGNED BY OTHERS (3) NEW VERIZON WIRELESS FLUSH MOUNTED PANEL ANTENNAS ELEVATION = [765.0'±] AMSL [91' -0 " ±] A.G.L. �YI� (3) NEW VERIZON WIRELESS FLUSH MOUNTED PANEL ANTENNAS ELEVATION = [756.5±] AMSL [82' -0 "±] A.G.L. SEE ENLARGED VIEW. THIS SHEET NEW VERIZON WIRELESS 95.0' A.G.L. MONOPOLE ENLARGED VIEW NOT TO SCALE 30 SEE ENLARGED VIEW. THIS SHEET NOTES 1. NO COMMERCIAL ADVERTISING MATERIAL WILL BE USED IN CONJUNCTION WITH THE NEW TOWER. 2. REGARDLESS OF THE LUMENS EMITTED, EACH OUTDOOR LUMINAIRE SHALL BE FULLY SHIELD AS REQUIRED BY SECTION 4.17 BY THE ZONING SUPPLEMENT #30, 10- 13 -04. 3. TOWER AND ALL OTHER ASSOCIATED EQUIPMENT TO BE PAINTED SHERWIN WILLIAMS MATTE "JAVA BROWN" #6090. 4. BASE OF TOWER NOT TO EXCEED 30" DIAMETER AND TOP NOT TO EXCEED 18" DIAMETER. 5. NEW SHELTER TO HAVE AN AGGREGATE FINISH. 6. ALL VERTICAL COAXIAL CABLES WILL BE RUN INSIDE OF THE MONOPOLE. 7. LIGHTNING ROD WILL NOT EXCEED 2' ABOVE THE TOWER AND WILL BE 1" DIAMETER ANTENNA NOTES Ij 1. ANTENNAS ARE TYPICAL FLUSH -MOUNT DESIGN USING MOUNTING COLLAR, BRACKET AND PIPE MOUNTS. 2. FINAL MOUNTING DESIGN MAY VARY SLIGHTLY DEPENDING ON AVAILABILITY AND SPECIFIC MANUFACTURER. 3. PROPOSED ANTENNAS - ANTEL BXA- 70063/8CF DIMENSIONS - 94.6 "(H) X 11.2 "(W) X 4.5 "(D) 4. PROPOSED ANTENNAS - ANTEL BXD - 63406380CF DIMENSIONS - 47.4 "(H) X 16.8 "(W) X 3.5 "(D) 12" MAX FACE OF NEW LTE (4G) ANTENNA (TYP OF 3) DUNTING COLLAR YP OF 2) DUNTING PIPE YP OF 3) CE OF NEW PCS /CELLULAR IALBAND ANTENNA (P OF 3) OF NEW MONOPOLE EW MONOPOLE ENLARGED VIEW NOT TO SCALE TOP OF COAX PORT gL ELEVATION = [680 -0 " ±] AMSL BEGINNING OF POLE ELEVATION = [674 -10 " ±] AMSL _ TOP OF FOUNDATION ELEVATION = [674' -6 " ±] AMSL FINISHED GRADE OTOWER_ AMSL ELEVATION - [874' -0'1] AMSL ,ture & Engineering 1331 L STREET, NW SUITE 600 WASHINGTON, DC 20005 2024613260 FAX 202.461.3266 veriZon wireless 1831 RADY COURT RICHMOND, VA 23222 TH aF �f1A o JUST TIN Y, Y00�� 9 Lie. No. 42897 /S /i 3 4� NA SITE INFO.: BOILING SIDING RAWLAND 3706 IRISH ROAD ESMONT, VA 22937 ALBEMARLE COUNTY DESIGN: JYY DRAWN: KAY TTV DATE: 12/95/07 COMM. NO. 3036.108 SUBMITTALS SYM. DESCPoPTION DATE Qi NSITE PLAN 08/30/12 EW SET IiIAVISED 09/11/12 105/15/11 PLICATION DRAWINGS 04/12/13 � /a\ APPLICATION DWGS SHEET NAME: ELEVATION VIEW SHEET NO.: C-3 E ® CONSTRUCTION NOTES 1. CORNER, END OR PULL POST 4" X 4" TREATED LUMBER SPACING FOR LINE POSTS IS 8' -0" CL TO (� MAX 2. TOP RAIL & BRACE RAIL- 2" X 4" TREATED LUMBER 3. 1" (NOMINAL) X 6" -8' DOG EARRED FENCE BOARDS. CEDAR PREFERRED. #1 TREATED ACCEPTABLE 4. 1 1/2" MAXIMUM CLEARANCE FROM GRADE 5. 2" FINISH OR AS DETERMINED BY CONSTRUCTION MANAGER DURING BID WALK 6. 4" COMPACT 95% BASE MATERIAL OR AS DETERMINED BY CONSTRUCTION MANAGER DURING BID WALK 7. FINISH GRADE SHALL BE UNIFORM AND LEVEL 8. DUCK BILL OPEN GATE HOLDER. VERIFY LOCATION IN FIELD PRIOR TO INSTALLATION. TYPICAL BOTH SIDES OF GATE 9. GEOTEXTILE FABRIC 10. GATE HARDWARE. MANUFACTURER NOT SPECIFIED AT THIS TIME 11. POST: CONCRETE FOUNDATION (2000 PSI) VARIFC — UT PI AN R' -n" TYP GENERAL NOTES 1. INSTALL FENCING PER ASTM F -567 2. INSTALL SWING GATES PER ASTM F- 900 3. LOCAL ORDINANCE OF BARBED WIRE PERMIT REQUIREMENT SHALL BE COMPLIED IF REQUIRED. 4. USE GALVANIZED (OR BETTER) NUTS, BOLTS AND WASHERS TO MOUNT ALL SIGNS (SECURED THROUGH FENCE BOARDS). COMPOUND FENCE DETAIL —1 (TMP) I~ NO SCALE VERIFY FINISHED MATERIAL REQUIREMENTS WITH CONSTRUCTION MANAGER PRIOR TO BID 1" MIN. ABOVE EXISTING GRADE 12' EXISTING 1 1/2" PER 6' OF SLOPE 1 1/2" PER 6' OF SLOPE GRADE COMPACT ROAD BASE MATERIAL REMOVE ORGANIC MATERIAL (3" MINIMUM) 5 1/2" MINIMUM / AT CROWN i GEOTEXTILE FABRIC WHERE REQUIRED. VERIFY WITH CONSTRUCTION MANAGER PRIOR TO BID EARTH WORK SUBGRADE COMPACTION & SELECT GRANULAR FILL A CONTRACTOR SHALL BE RESPONSIBLE FOR CLEARING & GRUBBING THE CONSTRUCTION SITE AND ROADWAY AREAS. THE CONTRACTOR SHALL COMPLY WITH THE RECOMMENDATIONS CONTAINED WITHIN THE GEOTECHNICAL REPORT WHEN NECESSARY PREPARED FOR THIS SITE FOR SITE WORK PREPARATION & FOUNDATION WORK. AS A MINIMUM THE TOP 3" OF GRADE SHALL BE REMOVED. THE EXPOSED SUBGRADE COMPACTED, GEOTEXTILE FABRIC AS REQUIRED FOR UNSTABLE SOIL CONDITION. B. ALL SELECT GRANULAR FILL SHALL BE COMPACTED TO A 95% COMPACTION AT A MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D -1557 OR WITHIN PLUS OR MINUS 3% OF OPTIMUM MOISTURE CONTENT, TYPICAL ACCESS ROAD CROSS SECTION NO SCALE NEW CHAIN LINK FENCE FABRIC T I 11� I N EXTERIOR FACILITY Z SIDE SIDE `a- 3 alll_I 6 I 9 - 1IIIIIII I ,`i is I_I �� 11 SECTION - COMPOUND AREA NO SCALE NEW FENCE POST NO.57 COARSE AGGREGATE BOTTOM LAYER OF MIRAFI HP570 GEOSYNTHETIC. EXTEND 2' BEYOND TOE OF AGGREGATE SLOPE, ALL AROUND COMPACT TOP 6" OF SUBGRADE /BASE MATERIAL TO 95% DENSITY PER ASTM D -1557 ,rchitecture & Engineers 1331 L STREET, P SUITE, WASHINGTON. DC 20 202.461.3260 FAX 202.461.3 VVWW.CLARKNEXSEN.0 veriLon wireless 1831 RADY COURT RICHMOND, VA 23222 T H of �f,A -JUSTIN Y. YOON Lic. No. 42897 •�� /25- /3 �ww NA SITE INFO.: BOILING SIDING RAWLAN D 3706 IRISH ROAD ESMONT, VA 22937 ALBEMARLE COUNTY DESIGN: DRAWN: REVIEW: TTV DATE: 12105)07 COMM. NO. 3036.108 SUBMITTALS SYM. DESCRIPTION DATE ENSUE PLAN D8 /30/12 z REVIEW SET 09/11/12 a kPPUCATION DRAWINGS D4 /12/13 a REVISED APPLICATION DWGS 05/15/13 Al %*Er NAME: DETAILS SHEET NO.: C -4 PLANTING SCHEDULE TYPE BOTANICAL NAME COMMON NAME QUANTITY REMARKS CALIPER HEIGHT SPREAD TREES MP MYERICA PENSYLVANICA NORTHERN BAYBERRY — — — 9 FULL, DENSE NOTES 1. THE CONTRACTOR SHALL VERIFY THAT TOTAL QUANTITIES INDICATED IN THE PLANT LIST OR SCHEDULE AGREES WITH QUANTITIES SHOWN ON PLANTING LAYOUT. IF DISCREPANCIES, USE TOTAL OF QUANTITIES SHOWN ON PLANTING LAYOUT. 2. THE CONTRACTOR SHALL PROVIDE THE QUANTITIES REQUIRED TO COMPLETE PROPOSED PLANTING AS SHOWN ON THE LANDSCAPE PLAN. 3. CONTRACTOR SHALL ENSURE POSITIVE DRAINAGE. 4. ALL BEDS SHALL BE CLEAN AND WEEDED. 5. ALL AREAS NOT PAVED OR PLANTED SHALL BE SEEDED. 6. PROVIDE ALL NECESSARY PLANT MATERIALS, LABOR, TOOLS, AND MATERIALS TO COMPLETE THIS PROJECT IN A WORKMANLIKE, PROFESSIONAL MANNER. 7. ALL TREES, SHRUBS, AND GROUND COVERS SHALL BE SPECIMEN QUALITY (AMERICAN ASSOCIATION OF NURSERYMEN STANDARDS), SHALL BE NURSERY— GROWN, AND IN A HEALTHY, INSECT AND DISEASE —FREE, CONDITION. 8. NO SUBSTITUTIONS OF SIZE OR VARIETY OF PLANT MATERIAL WITHOUT PRIOR APPROVAL OF LANDSCAPE DESIGNER. 9. STAKE TREES ACCORDING TO A.A.N. (AMERICAN ASSOCIATION OF NURSERYMEN) STANDARDS. 10. "B &B" INDICATES BALLED AND BURLAPPED. 11. "CON" INDICATES CONTAINERIZED PLANTS. 12. ALL TREES AND SHRUBS HAVE BEEN LOCATED WITH RESPECT TO PROPOSED OR EXISTING UTILITIES AS ACCURATELY AS POSSIBLE. FIELD VERIFY LOCATIONS FOR ALL UTILITIES PRIOR TO INSTALLING PLANT MATERIAL 13. VERIFY ALL DIMENSIONS IN THE FIELD, NOTIFY OWNER AND LANDSCAPE DESIGNER OF ANY VARIANCE FROM PLANS. 14. PROVIDE OWNER FULL 12 MONTHS MATERIAL AND LABOR GUARANTEE ON ALL PLANT MATERIAL. 15. TEST SOIL BEFORE PLANTING AND ADD PROPER SOIL AMENDMENTS TO SOIL TO ESTABLISH ph OF 6.5. 16. PREPARE SOIL WITH HI CALCIUM LIME @ RATE INDICATED ON SEEDING SCHEDULE (SEE SHEET L -2). 17. PRUNE ALL PLANT MATERIAL — REMOVE RANK AND DEAD GROWTH ONLY. PRUNE FOR NATURAL SHAPE PER SPECIES. 18. MULCH TO BE 2" MIN. DEPTH SHREDDED HARDWOOD BARK MULCH IN ALL BED AREAS. 19. ANY QUESTIONS REGARDING THE INSTALLATION OF THIS PROJECT SHOULD BE BROUGHT TO THE ATTENTION OF LANDSCAPE DESIGNER ® 757 - 455 -5800. 20. IN PLANTING BEDS, OMIT THE COMPACTED EARTH SAUCER AND COVER THE BEDS WITH MULCH (2" MIN. DEPTH). AT HEDGE ROWS PROVIDE MULCH IN A CONTINUOUS BED. ALL GROUPINGS OF SHRUBS SHALL BE INSTALLED IN CONTINUOUS MULCH BEDS. 21. WHERE PLANTING BEDS ABUT WALK AND CURBS, DEPRESS TOPS OF MULCHED BEDS 3/4 ". 22. TREE AND SHRUB PITS SHALL BE 3 TIMES SIZE OF ROOT BALL AND BACK FILLED WITH FOLLOWING SOIL MIXTURE THOROUGHLY MIXED: 2 PARTS SAND, 2 PARTS COMPOSTED HORSE MANURE OR CATTLE MANURE, OR ORGANIC COMPOST, AND 6 PARTS GOOD QUALITY TOPSOIL. NOTE: HEIGHT RESTRICTIONS LIMIT SELECTION OF PLANT MATERIAL LOCATED WITHIN THE DOMINION VIRGINIA POWER EASEMENT. IF ANOTHER SPECIES OF PLANT IS PREFERRED, SEE THE "SUGGESTED LIST OF PLANT SPECIES FOR SCREENING ON TRANSMISSION RIGHTS OF WAY" PROVIDED BY DOMINION VIRGINIA POWER. ALL OTHER PLANT MATERIAL NOT FOUND ON THIS LIST WILL HAVE TO BE SUBMITTED TO DOMINION VIRGINIA POWER FOR APPROVAL. ® CONSTRUCTION NOTES 1, TREE. SEE SCHEDULE THIS SHEET. SEE DETAIL 1, SHEET L -2. GRAPHIC SCALE(S) FOR 22" X 34' PLOT — 1" = 5' 0 5' 10' FOR 11" X 17" PLOT — 1" = 10' -ture & Engineer 1331 L STREET, SUITE WASHINGTON, DC 2C 202461.3260 FAX 202.461 veriMn wireless 1831 RADY COURT RICHMOND, VA 23222 T H of O � JUSTIX Y. ✓�. Lic. No. 42897 kLIONAL/I SREINFD.: BOILING SIDING RAWLAN D 3706 IRISH ROAD ESMONT, VA 22937 ALBEMARLE COUNTY SY111 DEsmFnON I DATE 1 ENSITE PLAN 08 /30/12 z REVIEW SEf 09/11/12 a PUCATON DRAWINGS 04 /12/13 A REVISED APPLICATION DWGS 05/15/13 9$T NAME LANDSCAPE PLAN 9$T NO.: L -1 y% Y N 3-8 1/8" r I I SCROLL FAN EXHAUST ELBOW W/SNAP IN SCREEN j STANDARD j LOCATION I I I I I � I I I WALL 4 'THICKNESS 1 I jO 1 PI „ 3/4" REAR WALL ELEVATION C 12 -0" r - - - I I I I I I I I I I I I I I I S-9 3/8" 2" SERVICE ENTRY I I I I I L J 5-9 3/8° c 6 D ELEVATION KEY LEFT WALL ELEVATION D 11 3/4' � 11' -7" RIGHT WALL ELEVATION B NOTE: PROPOSED BUILDING LIGHT FIXTURE WILL BE FRONT WALL ELEVATION A SHIELDED AND OPERATED BY A SWITCH, AND SHALL NOT BE OPERATED BY A PHOTOCELL. SHELTER ELEVATIONS NOT TO SCALE MIRRORED SHELTER NOTES 1. THE SHELTER SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE 2009 VIRGINIA UNIFORM STATEWIDE BUILDING CODE (VUSBC) EFFECTIVE MARCH 1, 2011. 2. REFER TO STRUCTURAL SHEETS FOR SHELTER EQUIPMENT AND SHELTER LOAD REQUIREMENTS. 3. BUILDING WILL BE PLACED ON CONCRETE PIERS. 4. BUILDING SHALL BE LOCATED FIVE FEET (5' -0 ") OR MORE FROM ANY PROPERTY LINE, INTERIOR LOT LINE OR ANY OTHER BUILDING. 5. BUILDING WILL HAVE A DARK BROWN, AGGREGATE STONE FINISH. 6. SHELTER IS TO BE CLASSIFIED AS USE GROUP U, TYPE HE CONSTRUCTION PER THE VUSBC. ure & Engineer 1331 L STREET, SUITE WASHINGTON, DC 2( 2024613260 FAX 202.461 veriZon wireless 1831 RADY COURT RICHMOND, VA 23222 JUSTIN Y, YOON Lic. No. 42897 3 k�IONAt i SITE INFO.: BOILING SIDING RAWLAN D 3706 IRISH ROAD ESMONT, VA 22937 ALBEMARLE COUNTY DESIGN: DRAWN: REVIEW: TTV DATE: 12/OS /D7 Isym-11 PTION DATE ,L � ENSITE PLAN 08/30/12 /2\ REVIEW SET 09/19/12 /a\ (REVISED APPLICATION DWGS 105/15/131 SHEET NAME: SHELTER ELEVATIONS SHEET NO.: A -1 12 -0" 5-9 3/8° 1 1 L - - - -J G I I 11 3/4' � 11' -7" RIGHT WALL ELEVATION B NOTE: PROPOSED BUILDING LIGHT FIXTURE WILL BE FRONT WALL ELEVATION A SHIELDED AND OPERATED BY A SWITCH, AND SHALL NOT BE OPERATED BY A PHOTOCELL. SHELTER ELEVATIONS NOT TO SCALE MIRRORED SHELTER NOTES 1. THE SHELTER SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE 2009 VIRGINIA UNIFORM STATEWIDE BUILDING CODE (VUSBC) EFFECTIVE MARCH 1, 2011. 2. REFER TO STRUCTURAL SHEETS FOR SHELTER EQUIPMENT AND SHELTER LOAD REQUIREMENTS. 3. BUILDING WILL BE PLACED ON CONCRETE PIERS. 4. BUILDING SHALL BE LOCATED FIVE FEET (5' -0 ") OR MORE FROM ANY PROPERTY LINE, INTERIOR LOT LINE OR ANY OTHER BUILDING. 5. BUILDING WILL HAVE A DARK BROWN, AGGREGATE STONE FINISH. 6. SHELTER IS TO BE CLASSIFIED AS USE GROUP U, TYPE HE CONSTRUCTION PER THE VUSBC. ure & Engineer 1331 L STREET, SUITE WASHINGTON, DC 2( 2024613260 FAX 202.461 veriZon wireless 1831 RADY COURT RICHMOND, VA 23222 JUSTIN Y, YOON Lic. No. 42897 3 k�IONAt i SITE INFO.: BOILING SIDING RAWLAN D 3706 IRISH ROAD ESMONT, VA 22937 ALBEMARLE COUNTY DESIGN: DRAWN: REVIEW: TTV DATE: 12/OS /D7 Isym-11 PTION DATE ,L � ENSITE PLAN 08/30/12 /2\ REVIEW SET 09/19/12 /a\ (REVISED APPLICATION DWGS 105/15/131 SHEET NAME: SHELTER ELEVATIONS SHEET NO.: A -1 Map is for Display Purposes Only • Aerial Imagery from the Commonwealth of Virginia and Other Sources May 22, 2013 COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 MEMORANDUM TO: Brent Nelson FROM: Margaret Maliszewski RE: ARB- 2013 -43 and SP- 2013 -11: Brochu (Verizon) Boiling Siding Tier 3 DATE: April 25, 2013 A balloon test was conducted on April 25, 2013 for the above referenced application. Routes 6, 722, 717 and 715 in the vicinity of the site were traveled to determine visibility. The balloon was visible from the Route 6 Entrance Corridor, but only in the immediate vicinity of the property, and when the balloon was visible, it was seen through a wooded area where the trees significantly minimized visibility. There were no sustained views of the balloon above the trees, as viewed from the EC. The narrowness and winding character of the road, and the wooded areas lining the road, contributed to minimizing the visibility of the balloon from the EC. Given the location of the ground equipment and the surrounding wooded area, the equipment is not expected to be seen from the EC. Overall, the visibility of the balloon was minimal and the proposed facility is not expected to have a negative impact on the EC. The balloon was also visible from Rt. 722 in the vicinity of the driveway at 7607 Old Green Mountain Road. From this location the balloon was also seen through wooded area, with the trees minimizing visibility. Regarding the ground equipment: The proposed ground equipment is not expected to be visible from the Entrance Corridor. Regarding visibility of the monopole: Given the extremely limited degree of visibility displayed at the balloon test, the proposed location of the facility is expected to sufficiently minimize the visibility of the monopole from the Route 6 EC such that no negative impact on the Entrance Corridor is anticipated. AL. ov 44 i W&Ag AM ti a. Oopa W71, ti a. le _ - FAr OPEN SPACE CONCEPT MAP Albemarle County, Virginia. JL4Y 15, 1992 Scale in miles Depa,l.ml al P;,,nmg and CO—mly D,Ialo aaant i ,*l - T-11 -141 • V, LEGEND MAJOR STRV 'ANI VALLEA'S: Witicl sup"I ' , Boundaries: ............... *." Witter SU11111) 11111"n'll(I'll"1111: Ricer lilla!'C BollildilrY Count), Scenic Stleam, m Slate §Ceni' Rivels: Natural MOUNTAINS: Critical slope, > 2514 FARMLANDS AND FOREST'S: CIVIC/CULTURAL H-A I URES; Registered 11ist"Tic 11'opellic': Schools and Park,: IIIIIIIIIIE I'LlbliC RCCjCjljj1nj \lC,jS: linlrance Corridors. VA Scenic Iligimms: womw Potential (ileelikkm Col.61jors: GROWTH AREAS: