Loading...
HomeMy WebLinkAboutARB201400043 Staff Report 2014-05-05ARCHITECTURAL REVIEW BOARD STAFF REPORT Project #/Name ARB- 2014 -43: Pantops Corner Review Type Initial Site Plan Parcel Identification 078000000005A0, 078000000005BO and 078000000058G1 Location 1248 Richmond Road, on the north side of Rt. 250, approximately 600' east of the intersection with Rt. 20, and on the east side of Rt. 20, across from Winding River Lane Zoned Highway Commercial (HC) and Entrance Corridor (EC) Owner /Applicant Pantops Corner LC /Shimp Engineering (Justin Shimp) Magisterial District Rivanna Proposal To construct two commercial /retail buildings totaling approximately 21,000 SF on 6.31 acres. Context The surrounding area is developed with a variety of commercial buildings and housing types. Adjacent development includes a thrift shop, car dealerships, a vacant auto body shop, and an electrical distributor. The property includes remnants of a house and garage. The perimeter of the property is wooded. A stream runs along the northern tip of the property. Visibility The building labeled Retail 2 will be readily visible from the Rt. 250 Entrance Corridor. It is located approximately 30' from the edge of the turn lane. The building labeled Retail 1 will also be visible from the Rt. 250 corridor. It is set back approximately 170' from Rt. 250. It is a much larger building and will be seen across a long parking lot. Retail 2 is not expected to have much visual impact on the Rt. 20 Entrance Corridor. Topography, existing buildings located along Rt. 20, and trees to be added along Rt. 20 are expected to limit direct views of Retail 1 from Rt. 20. ARB Meeting Date May 5, 2014 Staff Contact Margaret Maliszewski PROJECT HISTORY: A rezoning (ZMA2013 -01) was approved for this property on December 11, 2013. The ARB has reviewed no previous proposals for this site. ANALYSIS Gray highlight = means the guideline can't be reviewed at Initial Site Plan stage, but recommendations can be provided for final. Yellow highlight = means the guideline can only be reviewed for location/configuration at the Initial Plan stage. Regular text = means the guideline can be reviewed at Initial Plan stage, can be made a condition of Initial Plan approval, and can be the basis for denial. REF GUIDELINE ISSUE RECOMMENDATION Structure design 9 Building forms and features, including roofs, window Architectural designs have not yet been None at this time. doors, materials, colors and textures should be submitted for review. compatible with the forms and features of the significant historic buildings in the area, exemplified by (but not limited to) the buildings described in Appendix A [of the design guidelines]. The standard of compatibility can be met through scale, materials, and forms which may be embodied in architecture which is contemporary as well as traditional. The replication of important historic sites in Albemarle County is not the objective of these guidelines. 12 Architecture proposed within the Entrance Corridor should use forms, shapes, scale, and materials to create a cohesive whole. 14 Arcades, colonnades, or other architectural connecting devices should be used to unify groups of buildings within a development. 15 Trademark buildings and related features should be modified to meet the requirements of the Guidelines. 10 Buildings should relate to their site and the surrounding The Retail 2 building (73' x 55') is Note that architectural context of buildings. smaller than many of the surrounding buildings, and the Retail 1 building treatments will be required for both 11 The overall design of buildings should have human scale. Scale should be integral to the building and site (130' x 160 ") is larger. Architectural buildings to relate the design. treatments will be required to relate the buildings to their surrounding context buildings to the surrounding context, to 13 Any appearance of "blankness" resulting from building design should be relieved using design detail or to achieve human scale and to relieve achieve human scale, and vegetation, or both. blankness. to relieve blankness. 16 Window glass in the Entrance Corridors should not be Information on window glass has not Provide information on highly tinted or highly reflective. Window glass in the yet been submitted for review. window glass with the Entrance Corridors should meet the following criteria: next submittal. Indicate Visible light transmittance (VLT) shall not drop below on the plan that visible 40 %. Visible light reflectance (VLR) shall not exceed light transmittance (VLT) 30 %. Specifications on the proposed window glass should shall not drop below 40% be submitted with the application for final review. and visible light reflectance (VLR) shall not exceed 30 %. Accessory structures and equipment 17 Accessory structures and equipment should be A loading dock is proposed on the Provide a mix of species integrated into the overall plan of development and north side of the Retail 1 building and a in the row of screening shall, to the extent possible, be compatible with the dumpster pad is proposed just beyond trees located north of the building designs used on the site. the northeast corner of Retail 1, on the north side of the loading travelway. A Retail 1 loading area. 18 The following should be located to eliminate visibility from the Entrance Corridor street. If, after appropriate staggered row of screening trees is siting, these features will still have a negative visual shown along the loading area and impact on the Entrance Corridor street, screening around the dumpster pad. Depending should be provided to eliminate visibility. on the size and species of tree a. Loading areas, proposed, the row of trees will likely b. Service areas, screen the loading area, but a mix of c. Refuse areas, trees could result in an improved d. Storage areas, appearance and healthier landscape. e. Mechanical equipment, f. Above - ground utilities, and g. Chain link fence, barbed wire, razor wire, and similar security fencing devices. 19 Screening devices should be compatible with the design of the buildings and surrounding natural vegetation and may consist of: a. Walls, b. Plantings, and c. Fencing. 20 Surface runoff structures and detention ponds should A large retention pond is proposed to Locate the sanitary and be designed to fit into the natural topography to avoid be located north of Retail 1. It is storm sewer lines to the need for screening. When visible from the located approximately 200' from the allow planting area Entrance Corridor street, these features must be fully Rt. 20 EC. The top of the embankment sufficient to integrated into the landscape. They should not have around the facility is at an elevation of accommodate trees on the appearance of engineered features. 378'. The elevation of Rt. 20 in the vicinity is around 350'. With the west side of Retail 1. 44 Natural drainage patterns (or to the extent required, new drainage patterns) should be incorporated into the appropriate landscaping along Rt. 20, finished site to the extent possible. the pond is not expected to have a negative impact on the EC. A storm pipe and a sanitary sewer line run along the western side of Retail 1. Additional space may be needed for planting in this area, depending on the design of the building. 21 The following note should be added to the site plan and The note is needed on the plan. Add the standard the architectural plan: "Visibility of all mechanical mechanical equipment equipment from the Entrance Corridor shall be note to the site plan and eliminated." architectural drawings. Lighting Lighting information has not yet been provided for review. Landscaping 7 The requirements of the Guidelines regarding Appropriate landscaping will be See recommendations landscaping are intended to reflect the landscaping required, both at the perimeters and at below. characteristic of many of the area's significant historic the interior of the site, to integrate this sites which is characterized by large shade trees and development into the surroundings. lawns. Landscaping should promote visual order within the Entrance Corridor and help to integrate buildings into the existing environment of the corridor. 32 Landscaping along the frontage of Entrance Corridor Large shade trees are shown along Rt. Include the full Rt. 20 streets should include the following: 250 and Rt. 20 at 35' on center. frontage in the site plan, a. Large shade trees should be planted parallel to the Ornamentals are interspersed. A small at a consistent scale. Entrance Corridor Street. Such trees should be at least portion of the Rt. 20 frontage is not Show the telephone and 3' /2 inches caliper (measured 6 inches above the ground) included on the plan. fiber optic lines and and should be of a plant species common to the area. easement out to Rt. 20. Such trees should be located at least every 35 feet on Overhead lines exist along Rt. 250. It is center. difficult to see the location of the lines Revise the plan to clearly b. Flowering ornamental trees of a species common to and the associated easement on the show all existing and the area should be interspersed among the trees plans. proposed utilities and required by the preceding paragraph. The ornamental easements. Locate trees need not alternate one for one with the large shade trees. They may be planted among the large A sanitary sewer line runs along Rt. 20. utilities and easements to shade trees in a less regular spacing pattern. eliminate conflicts with c. In situations where appropriate, a three or four board Underground telephone and fiber optic required landscaping. fence or low stone wall, typical of the area, should align lines run across the property near the Show all required the frontage of the Entrance Corridor street. north end of parcel 58G1. They may landscaping outside of d. An area of sufficient width to accommodate the conflict with some of the planting utilities and easements. foregoing plantings and fencing should be reserved required along the Rt. 20 EC. parallel to the Entrance Corridor street, and exclusive of road right -of -way and utility easements. 33 Landscaping along interior roads: Large trees are shown 40'on center None. a. Large trees should be planted parallel to all interior along the proposed private road. roads. Such trees should be at least 21/2 inches caliper (measured six inches above the ground) and should be of a plant species common to the area. Such trees should be located at least every 40 feet on center. 34 Landscaping along interior pedestrian ways: A sidewalk is proposed along the south Note that trees may be a. Medium trees should be planted parallel to all interior (front) and east elevations of Retail 1, required on the south side pedestrian ways. Such trees should be at least 21/2 inches but trees are not provided along the of Retail 1 and the west caliper (measured six inches above the ground) and south elevation. Trees may be needed, side of Retail 2, should be of a species common to the area. Such trees depending on the architectural design depending on the should be located at least every 25 feet on center. of the building. Sidewalks are proposed proposed architectural along the north, west and part of the designs. south elevation of Retail 2. No trees are provided along the west elevation. Trees may be needed, depending on the architectural design of the building. 35 Landscaping of parking areas: Trees are proposed at 40' on center Add tree islands, with a. Large trees should align the perimeter of parking along the western perimeter of the large trees 21/2" caliper at areas, located 40 feet on center. Trees should be planted parking lot. Retaining walls run along planting, in the central in the interior of parking areas at the rate of one tree for the eastern perimeter. Shrubs are double parking row to every 10 parking spaces provided and should be evenly proposed between the walls, but there break up the expanse of distributed throughout the interior of the parking area. are no trees proposed along the eastern paved area. Add at least 5 b. Trees required by the preceding paragraph should perimeter of the lot. more trees at the interior measure 21/2 inches caliper (measured six inches above of the parking lot. the ground); should be evenly spaced; and should be of An undeveloped area approximately a species common to the area. Such trees should be 65' wide remains between the parking Add shrubs, minimum planted in planters or medians sufficiently large to lot and the adjacent parcels to the west. 24" high at planting, maintain the health of the tree and shall be protected by along the western curbing. 122 parking spaces are proposed, perimeter of the parking c. Shrubs should be provided as necessary to minimize which requires 12 interior trees. Only 7 lot, along the Rt. 250 EC the parking area's impact on Entrance Corridor streets. interior trees are proposed. Given the frontage, and along the Shrubs should measure 24 inches in height. size of the parking lot and its proximity private drive from Rt. to, and visibility from, the Rt. 250 EC, 250 to Retail 1. additional tree islands in the central double parking row would be Add trees 40' on center, appropriate to break up the expanse of 21/2" caliper at planting, paved area. along the eastern perimeter of the parking Shrubs are proposed on the southern lot. end of the parking lot and on the west and south sides of Retail 2. They are not provided consistently along the Rt. 250 frontage. Given the size of the parking lot and its proximity to, and visibility from, the Rt. 250 EC, shrubs would be appropriate along the western perimeter of the parking lot, along the EC frontage, and along the private drive from Rt. 250 to Retail 1. 36 Landscaping of buildings and other structures: Architectural designs have not yet been Note that trees and a. Trees or other vegetation should be planted along the submitted for review, but trees and shrubs may be required front of long buildings as necessary to soften the shrubs may be needed along the along the proposed appearance of exterior walls. The spacing, size, and proposed buildings, particularly Retail buildings, to mitigate type of such trees or vegetation should be determined 1 due to its size, to mitigate appearances. by the length, height, and blankness of such walls. appearances. b. Shrubs should be used to integrate the site, buildings, and other structures; dumpsters, accessory buildings and structures; "drive thru" windows; service areas; and signs. Shrubs should measure at least 24 inches in height. 37 Plant species: Plants species have not yet been To help promote a a. Plant species required should be as approved by the identified. healthy landscape, limit Staff based upon but not limited to the Generic the number of any single Landscape Plan Recommended Species List and Native species proposed to 25% Plants for Virginia Landscapes (Appendix D). of the total proposed for that plant type (tree or shrub). 38 Plant health: The note will be needed. Add the standard The following note should be added to the landscape planting note to the plan. plan: "All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant." Development pattern 6 Site development should be sensitive to the existing The existing rolling terrain will be See landscaping natural landscape and should contribute to the creation mostly lost with the proposed recommendations. of an organized development plan. This may be development. The re- graded slopes at accomplished, to the extent practical, by preserving the the north end of the property will have trees and rolling terrain typical of the area; planting new a very regular appearance. The trees trees along streets and pedestrian ways and choosing proposed along the Rt. 20 EC will help species that reflect native forest elements; insuring that mitigate the view of this grading. any grading will blend into the surrounding topography Retaining walls are proposed in the thereby creating a continuous landscape; preserving, to southern half of the development. With the extent practical, existing significant river and stream appropriate materials and landscaping, valleys which may be located on the site and integrating retaining walls can have an appropriate these features into the design of surrounding appearance in the ECs. development; and limiting the building mass and height to a scale that does not overpower the natural settings of The site layout appears generally the site, or the Entrance Corridor. organized. A new private road is 39 The relationship of buildings and other structures to the proposed from Rt. 250 to Rt. 20. Entrance Corridor street and to other development within the corridor should be as follows: a. An organized pattern of roads, service lanes, bike The proposed buildings are oriented paths, and pedestrian walks should guide the layout of parallel to the Rt. 250 EC. The the site. sidewalk layout suggests that the Retail b. In general, buildings fronting the Entrance Corridor 2 building will have an entrance facing street should be parallel to the street. Building the EC. groupings should be arranged to parallel the Entrance Corridor street. The perimeters of the site are wooded. c. Provisions should be made for connections to The plan shows all existing trees to be adjacent pedestrian and vehicular circulation systems. removed for the development of the d. Open spaces should be tied into surrounding areas to site. This will change the general provide continuity within the Entrance Corridor. appearance of this area as viewed from e. If significant natural features exist on the site both ECs, because many of the trees (including creek valleys, steep slopes, significant trees that are currently viewed as backdrop or rock outcroppings), to the extent practical, then such for the buildings that front Rt. 20, and natural features should be reflected in the site layout. If the trees that act as backdrop for the the provisions of Section 32.5.6.n of the Albemarle thrift store, and trees that buffer the County Zoning Ordinance apply, then improvements western side of the Ford dealership, required by that section should be located so as to will be removed. maximize the use of existing features in screening such improvements from Entrance Corridor streets. £ The placement of structures on the site should respect existing views and vistas on and around the site. Site Grading 40 Site grading should maintain the basic relationship of Four retaining walls are proposed. The Round contours with a ten the site to surrounding conditions by limiting the use of walls reach maximum heights of 6', 2', foot minimum radius retaining walls and by shaping the terrain through the 12' and 6' (beginning with the western where they meet the use of smooth, rounded land forms that blend with the wall and moving east). Shrubs are adjacent condition. Final existing terrain. Steep cut or fill sections are generally proposed between the two eastern grading should achieve a unacceptable. Proposed contours on the grading plan walls, but no plants are shown at the natural, rather than shall be rounded with a ten foot minimum radius where top of the easternmost wall. Trees engineered, appearance. they meet the adjacent condition. Final grading should along the eastern property line would achieve a natural, rather than engineered, appearance. be appropriate. (Trees are provided Provide trees consistently Retaining walls 6 feet in height and taller, when along the private road, beyond the along the eastern necessary, shall be terraced and planted to blend with endpoint of the retaining wall.) Some perimeter of the site. the landscape. types of retaining walls can't Provide retaining wall accommodate this type of planting. details on the plan with sufficient information to Contours are not rounded in many confirm that the trees can locations. be accommodated near the wall. 41 No grading, trenching, or tunneling should occur The plan shows all existing trees to be None. SUMMARY OF RECOMMENDATIONS Staff recommends the following as the primary points of discussion: 1. Additional landscaping needed: trees at the interior of the parking lot, trees along the east side of the site, shrubs on the west side of the parking lot 2. Visibility /treatment of the retention pond 3. Retaining walls — visibility, treatment, planting 4. Utilities /easements and landscaping Staff recommends that the ARB forward the following recommendations to the Agent for the Site Review Committee: 0- Regarding requirements to satisfy the design guidelines as per § 18- 30.6.4(2), (3) and (5): None. • Regarding recommendations on the plan as it relates to the guidelines: None. • Regarding recommended conditions of initial plan approval: • A Certificate of Appropriateness is required prior to final site plan approval. • Add tree islands, with large trees 2'/2" caliper at planting, in the central double parking row to break up the expanse of paved area. Add at least 5 more trees at the interior of the parking lot. • Add trees 40' on center, 2%2" caliper at planting, along the eastern perimeter of the parking lot. • Revise the plan to clearly show all existing and proposed utilities and easements. Locate utilities and easements to eliminate conflicts with required landscaping. Show all required landscaping outside of utilities and easements. • Regarding conditions to be satisfied prior to issuance of a grading permit: None. within the drip line of any trees or other existing removed for the development of the features designated for preservation in the final site. Certificate of Appropriateness. Adequate tree protection fencing should be shown on, and coordinated throughout, the grading, landscaping and erosion and sediment control plans. 42 Areas designated for preservation in the final Certificate of Appropriateness should be clearly delineated and protected on the site prior to any grading activity on the site. This protection should remain in place until completion of the development of the site. 43 Preservation areas should be protected from storage or movement of heavy equipment within this area. SUMMARY OF RECOMMENDATIONS Staff recommends the following as the primary points of discussion: 1. Additional landscaping needed: trees at the interior of the parking lot, trees along the east side of the site, shrubs on the west side of the parking lot 2. Visibility /treatment of the retention pond 3. Retaining walls — visibility, treatment, planting 4. Utilities /easements and landscaping Staff recommends that the ARB forward the following recommendations to the Agent for the Site Review Committee: 0- Regarding requirements to satisfy the design guidelines as per § 18- 30.6.4(2), (3) and (5): None. • Regarding recommendations on the plan as it relates to the guidelines: None. • Regarding recommended conditions of initial plan approval: • A Certificate of Appropriateness is required prior to final site plan approval. • Add tree islands, with large trees 2'/2" caliper at planting, in the central double parking row to break up the expanse of paved area. Add at least 5 more trees at the interior of the parking lot. • Add trees 40' on center, 2%2" caliper at planting, along the eastern perimeter of the parking lot. • Revise the plan to clearly show all existing and proposed utilities and easements. Locate utilities and easements to eliminate conflicts with required landscaping. Show all required landscaping outside of utilities and easements. • Regarding conditions to be satisfied prior to issuance of a grading permit: None. Staff offers the following comments on the preliminary proposal: 1. Note that architectural treatments will be required for both buildings to relate the buildings to the surrounding context, to achieve human scale, and to relieve blankness. 2. Provide information on window glass with the next submittal. Indicate on the plan that visible light transmittance (VLT) shall not drop below 40% and visible light reflectance (VLR) shall not exceed 30 %. 3. Provide a mix of species in the row of screening trees located north of the Retail 1 loading area. 4. Locate the sanitary and storm sewer lines to allow planting area sufficient to accommodate trees on the west side of Retail 1. 5. Add the standard mechanical equipment note to the site plan and architectural drawings. "Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated." 6. Include the full Rt. 20 frontage in the site plan, at a consistent scale. Show the telephone and fiber optic lines and easement out to Rt. 20. 7. Revise the plan to clearly show all existing and proposed utilities and easements. Locate utilities and easements to eliminate conflicts with required landscaping. Show all required landscaping outside of utilities and easements. 8. Note that trees may be required on the south side of Retail 1 and west side of Retail 2, depending on the proposed architectural designs. 9. Add tree islands, with large trees 2'/2" caliper at planting, in the central double parking row to break up the expanse of paved area. Add at least 5 more trees at the interior of the parking lot. 10. Add shrubs, minimum 24" high at planting, along the western perimeter of the parking lot, along the Rt. 250 EC frontage, and along the private drive from Rt. 250 to Retail 1. 11. Note that trees and shrubs may be required along the proposed buildings, to mitigate appearances. 12. To help promote a healthy landscape, limit the number of any single species proposed to 25% of the total proposed for that plant type (tree or shrub). 13. Add the standard planting note to the plan: "All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant." 14. Round contours with a ten foot minimum radius where they meet the adjacent condition. Final grading should achieve a natural, rather than engineered, appearance. 15. Provide trees, 40' on center, 2%2" caliper at planting, consistently along the eastern perimeter of the site. Provide retaining wall details on the plan with sufficient information to confirm that the trees can be accommodated near the wall. 16. Correct the scale shown in the title block on sheet 3 of 8. TABLE A This report is based on the following submittal items: Sheet # Drawing Name Drawing Date Sheet # Drawing Name Drawing Date Cl Cover Sheet 3/24/2014 C5 Site Plan 3/24/2014 C2 Project Overview /Sheet Index 3/24/2014 C6 Landscape Plan 3/24/2014 C3 Existing Conditions & Demo Plan 3/24/2014 C7 Landscape Plan 3/24/2014 C4 Site Plan 3/24/2014 C8 Private Road Profile & Site Details 3/24/2014 10