Loading...
HomeMy WebLinkAboutARB201400006 Staff Report 2014-01-221 ARCHITECTURAL REVIEW BOARD STAFF REPORT Project #/Name ARB-2014-06: Out of Bounds Initial Site Plan Review Type Initial Site Development Plan Parcel Identification 06000000006500 Location 225 Out of Bounds Road, on the south side of Barracks Road, across from Georgetown Road Zoned Neighborhood Model District (NMD), Entrance Corridor (EC) Owner/Applicant Barracks Heights LLC/Shimp Engineering (Justin Shimp) Magisterial District Jack Jouett Proposal To construct 21 single family attached units, 26 townhouse units, and 8 multi-family units, with an existing single family residence. Context The subject parcel is located in an area mixed with single family residences and senior living and apartment buildings. The front of the site is an open field; the back is wooded. A brick residence built ca. 1940 and its outbuildings stand on the property. Visibility The proposed development will be readily visible from the Barracks Road Entrance Corridor. When construction of the entire development is complete, it is anticipated that the blocks of the development located towards the rear of the property will be hidden from view by the blocks located closer to the EC. Block 1, which is adjacent to the EC, will have the greatest visibility. Block 3 is expected to have minimal visibility, due to its location behind Block 1. ARB Meeting Date March 3, 2014 Staff Contact Margaret Maliszewski 2 PROJECT HISTORY DATE APPLICATION RESULT 11/18/2013 ZMA-2012-03 A rezoning from R1 Residential to Neighborhood Model District was approved for this project. ANALYSIS Gray highlight = means the guideline can’t be reviewed at initial site plan stage, but recommendations can be provided for final Yellow highlight = means the guideline can only be reviewed for location/configuration at the initial plan stage Regular text = means the guideline can be reviewed at initial plan stage, can be made a condition of initial plan approval, and can be the basis for denial REF GUIDELINE ISSUE RECOMMENDATION 1 The goal of the regulation of the design of development within the designated Entrance Corridors is to insure that new development within the corridors reflects the traditional architecture of the area. Therefore, it is the purpose of ARB review and of these Guidelines, that proposed development within the designated Entrance Corridors reflect elements of design characteristic of the significant historical landmarks, buildings, and structures of the Charlottesville and Albemarle area, and to promote orderly and attractive development within these corridors. Applicants should note that replication of historic structures is neither required nor desired. Architectural designs were not submitted with the initial plan, so a detailed assessment of the appearance of the proposed residences cannot be provided at this time. However, the plan shows that the backs of the Block 1 buildings face the street. Although building fronts facing the EC would have a more appropriate appearance, open space is provided between the EC and the Block 1 lots. This area is partially occupied by utilities (sanitary sewer, a stormwater facility and a power line to be moved underground, which does not show consistently on the drawings), but it appears that planting area will remain available. A conceptual landscape plan shows a mix of trees in this area. However, the planting will differ from that shown on the conceptual plan due to and updated BMP design. Appropriately designed landscaping, likely exceeding the minimum EC requirements, could sufficiently mitigate the impacts of Coordinate all sheets of the site plan regarding the three-board fence to remain along the EC and the power line to be moved underground. Provide landscaping along the Barracks Road frontage to meet the EC guidelines requirements and to mitigate the back of the Block 1 buildings facing the EC. Identify the plant species in the plant list. Increase plant sizes in the plant list to meet EC requirements. 2 Visitors to the significant historical sites in the Charlottesville and Albemarle area experience these sites as ensembles of buildings, land, and vegetation. In order to accomplish the integration of buildings, land, and vegetation characteristic of these sites, the Guidelines require attention to four primary factors: compatibility with significant historic sites in the area; the character of the Entrance Corridor; site development and layout; and landscaping. 3 New structures and substantial additions to existing structures should respect the traditions of the architecture of historically significant buildings in the Charlottesville and Albemarle area. Photographs of historic buildings in the area, as well as drawings of architectural features, which provide important examples of this tradition are contained in Appendix A. 4 The examples contained in Appendix A should be used as a guide for building design: the standard of compatibility with the area’s historic structures is not intended to impose a rigid design 3 solution for new development. Replication of the design of the important historic sites in the area is neither intended nor desired. The Guideline’s standard of compatibility can be met through building scale, materials, and forms which may be embodied in architecture which is contemporary as well as traditional. The Guidelines allow individ uality in design to accommodate varying tastes as well as special functional requirements. the rear elevations facing the EC. The conceptual landscape plan does not include species and the plant sizes specified are smaller than the guidelines requirements. A three-board fence runs along the property on the EC side and the west side of the site. The Existing Conditions and Demo Plan indicates that the fence is to remain along the EC. The fence in this location is appropriate. However, the site plan sheets do not consistently show the fence. The applicant has indicated that construction will begin with Blocks 4 and 5, and with landscaping along the EC. Consequently, these blocks, which have rear elevations facing the EC, will have greater visibility for a period of time, until the EC landscaping matures and the Block 1 buildings are constructed. Block 4 is located 400-550’ from the EC. Block 5 is located 700-800’ from the EC. Since the rear blocks will be visible for an unspecified period of time, it is recommended that the architectural designs for all the blocks be reviewed by the ARB. 5 It is also an important objective of the Guidelines to establish a pattern of compatible architectural characteristics throughout the Entrance Corridor in order to achieve unity and coherence. Building designs should demonstrate sensitivity to other nearby structures within the Entrance Corridor. Where a designated corridor is substantially developed, these Guidelines require striking a careful balance between harmonizing new development with the existing character of the corridor and achieving compatibility with the significant historic sites in the area. 9 Building forms and features, including roofs, windows, doors, materials, colors and textures should be compatible with the forms and features of the significant historic buildings in the area, exemplified by (but not limited to) the buildings described in Appendix A [of the design guidelines]. The standard of compatibility can be met through scale, materials, and forms which may be embodied in architecture which is contemporary as well as traditional. The replication of important historic sites in Albemarle County is not the objective of these guidelines. 20 Surface runoff structures and detention ponds should be designed to fit into the natural topography to avoid the need for screening. When visible from the Entrance Corridor street, these features must be fully integrated into the landscape. They should not have the appearance of engineered features. 32 Landscaping along the frontage of Entrance Corridor streets should include the following: a. Large shade trees should be planted parallel to the Entrance Corridor Street. Such trees should be at least 3½ inches caliper (measured 6 inches above the ground) and should be of a plant species common to the area. Such trees should be located at least every 35 feet on center. b. Flowering ornamental trees of a species common to the area should be interspersed among the trees required by the preceding paragraph. The ornamental trees need not alternate one for one 4 with the large shade trees. They may be planted among the large shade trees in a less regular spacing pattern. c. In situations where appropriate, a three or four board fence or low stone wall, typical of the area, should align the frontage of the Entrance Corridor street. d. An area of sufficient width to accommodate the foregoing plantings and fencing should be reserved parallel to the Entrance Corridor street, and exclusive of road right-of-way and utility easements. 10 Buildings should relate to their site and the surrounding context of buildings. The building footprints suggest traditional residential forms, which would relate to the surrounding context of residential buildings. Maximum building height is identified as 45’, which is not expected to appear out of proportion with the surroundings. The residential units are not expected to have blank elevations. None. 11 The overall design of buildings should have human scale. Scale should be integral to the building and site design. 12 Architecture proposed within the Entrance Corridor should use forms, shapes, scale, and materials to create a cohesive whole. 13 Any appearance of “blankness” resulting from building design should be relieved using design detail or vegetation, or both. 14 Arcades, colonnades, or other architectural connecting devices should be used to unify groups of buildings within a development. 15 Trademark buildings and related features should be modified to meet the requirements of the Guidelines. Architectural information addressing these issues has not yet been submitted for review. None at this time. 16 Window glass in the Entrance Corridors should not be highly tinted or highly reflective. Window glass in the Entrance Corridors should meet the following criteria: Visible light transmittance (VLT) shall not drop below 40%. Visible light reflectance (VLR) shall not exceed 30%. Specifications on the proposed window glass should be submitted with the applicat ion for final review. Accessory structures and equipment 17 Accessory structures and equipment should be integrated into the overall plan of development and shall, to the extent possible, be compatible with the building designs used on the site. The proposed residential development does not include loading, service or storage areas. Typical residential-scale refuse areas and mechanical equipment are expected in the development, and those in Block 1 may be visible from the EC. Appropriately designed landscaping could sufficiently mitigate the impacts of these features. A new green PVC fence is proposed for the See landscape recommendations. Specify a dark, matte finish for the PVC fence. 18 The following should be located to eliminate visibility from the Entrance Corridor street. If, after appropriate siting, these features will still have a negative visual impact on the Entrance Corridor street, screening should be provided to eliminate visibility. a. Loading areas, b. Service areas, c. Refuse areas, d. Storage areas, e. Mechanical equipment, f. Above-ground utilities, and g. Chain link fence, barbed wire, razor wire, and similar security fencing devices. 5 19 Screening devices should be compatible with the design of the buildings and surrounding natural vegetation and may consist of: a. Walls, b. Plantings, and c. Fencing. east and west sides of the site. PVC is not a preferred material for fences in the ECs. It often has a very smooth surface with a high gloss finish that does not resemble the wood that it replaces. However, a dark matte finish, together with the proposed landscaping, could result in an appropriate appearance. 21 The following note should be added to the site plan and the architectural plan: “Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated.” This note will be required on the site and architectural plans. Add the standard mechanical equipment note to the site and architectural drawings. Lighting Lighting is not proposed at this time. None at this time. Landscaping 7 The requirements of the Guidelines regarding landscaping are intended to reflect the landscaping characteristic of many of the area’s significant historic sites which is characterized by large shade trees and lawns. Landscaping should promote visual order within the Entrance Corridor and help to integrate buildings into the existing environment of the corridor. A small part of the existing lawn will remain associated with the 1940s house. Increased landscaping could help mitigate the back of building appearance in Block 1, which is adjacent to the EC, and help integrate the development into the overall EC. A note on the conceptual landscape plan indicates large or medium trees for the interior roads. The guidelines requirement is for large trees. The sizes in the plant list do not meet guidelines requirements. Sidewalks run along the interior roads, where trees are proposed. It appears that with the current layout, easements, including sanitary, storm and sight distance, will eliminate some required Provide planting area free of utilities and easements along the extension of Georgetown Road and Road A. Provide large trees, 2½” caliper at planting, consistently spaced 40’ on center, along interior roads. 8 Continuity within the Entrance Corridor should be obtained by planting different types of plant materials that share similar characteristics. Such common elements allow for more flexibility in the design of structures because common landscape features will help to harmonize the appearance of development as seen from the street upon which the Corridor is centered. 33 Landscaping along interior roads: a. Large trees should be planted parallel to all interior roads. Such trees should be at least 2½ inches caliper (measured six inches above the ground) and should be of a plant species common to the area. Such trees should be located at least every 40 feet on center. 34 Landscaping along interior pedestrian ways: a. Medium trees should be planted parallel to all interior pedestrian ways. Such trees should be at least 2½ inches caliper (measured six inches above the ground) and should be of a species common to the area. Such trees should be located at least every 25 feet on center. 6 planting area along the extension of Georgetown Road near the entrance to the site and along Road A. 35 Landscaping of parking areas: a. Large trees should align the perimeter of parking areas, located 40 feet on center. Trees should be planted in the interior of parking areas at the rate of one tree for every 10 parking spaces provided and should be evenly distributed throughout the interior of the parking area. b. Trees required by the preceding paragraph should measure 2½ inches caliper (measured six inches above the ground); should be evenly spaced; and should be of a species common to the area. Such trees should be planted in planters or medians sufficiently large to maintain the health of the tree and shall be protected by curbing. c. Shrubs should be provided as necessary to minimize the parking area’s impact on Entrance Corridor streets. Shrubs should measure 24 inches in height. One 12-space parking lot is provided in Block 3. No area is provided for interior trees. Some limited area is available for perimeter trees. 2½” caliper trees will be required. Shrubs at this parking lot will not likely have a significant impact on the view of the lot as seen from the EC. Provide perimeter parking lot trees for the Block 3 parking lot using large trees, 2½” caliper at planting, in a quantity equivalent to 40’ on center spacing, plus one tree to meet the interior tree requirement. 36 Landscaping of buildings and other structures: a. Trees or other vegetation should be planted along the front of long buildings as necessary to soften the appearance of exterior walls. The spacing, size, and type of such trees or vegetation should be determined by the length, height, and blankness of such walls. b. Shrubs should be used to integrate the site, buildings, and other structures; dumpsters, accessory buildings and structures; “drive thru” windows; service areas; and signs. Shrubs should measure at least 24 inches in height. Grading in the vicinity of units 7-14 eliminates on-site trees behind the units. Trees added behind the units and along the western perimeter of Open Space A would provide some softening for the rear elevations and help integrate the overall development, without relying on off-site planting. Provide trees behind units 7-14 and along the western perimeter of Open Space A. 37 Plant species: a. Plant species required should be as approved by the Staff based upon but not limited to the Generic Landscape Plan Recommended Species List and Native Plants for Virginia Landscapes (Appendix D). Plant species have not been identified at this time. Not at this time. 38 Plant health: The following note should be added to the landscape plan: “All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant.” This note will be needed on the landscape plan. Include the standard planting note on the site plan. Development pattern 6 Site development should be sensitive to the existing natural The Block 1 buildings are oriented parallel See the landscaping 7 landscape and should contribute to the creation of an organized development plan. This may be accomplished, to the extent practical, by preserving the trees and rolling terrain typical of the area; planting new trees along streets and pedestrian ways and choosing species that reflect native forest elements; insuring that any grading will blend into the surrounding topography thereby creating a continuous landscape; preserving, to the extent practical, existing significant river and stream valleys which may be located on the site and integrating these features into the design of surrounding development; and limiting the building mass and height to a scale that does not overpower the natural settings of the site, or the Entrance Corridor. to the EC, but the backs of the buildings face the EC. Increased landscaping could help mitigate the back of building appearance while establishing a coordinated streetscape along the corridor. Sidewalk connections are made throughout the development. Open space is provided throughout the development. A significant portion of the site is wooded, and much of the wooded area will be removed to make way for the proposed development. A residence constructed ca. 1940 in a traditional style is to remain and is incorporated into the development. No views are expected to be negatively impacted by the proposal. recommendations. 39 The relationship of buildings and other structures to the Entrance Corridor street and to other development within the corridor should be as follows: a. An organized pattern of roads, service lanes, bike paths, and pedestrian walks should guide the layout of the site. b. In general, buildings fronting the Entrance Corr idor street should be parallel to the street. Building groupings should be arranged to parallel the Entrance Corridor street. c. Provisions should be made for connections to adjacent pedestrian and vehicular circulation systems. d. Open spaces should be tied into surrounding areas to provide continuity within the Entrance Corridor. e. If significant natural features exist on the site (including creek valleys, steep slopes, significant trees or rock outcroppings), to the extent practical, then such natural features should be reflected in the site layout. If the provisions of Section 32.5.6.n of the Albemarle County Zoning Ordinance apply, then improvements required by that section should be located so as to maximize the use of existing features in screening such improvements from Entrance Corridor streets. f. The placement of structures on the site should respect existing views and vistas on and around the site. Site Grading 40 Site grading should maintain the basic relationship of the site to surrounding conditions by limiting the use of retaining walls and by shaping the terrain through the use of smooth, rounded land forms that blend with the existing terrain. Steep cut or fill sections are generally unacceptable. Proposed contours on the grading plan shall be rounded with a ten foot minimum radius where they meet the adjacent condition. Final grading should achieve a natural, Proposed grading does not significantly change the relationship of the site to its surroundings. One small retaining wall is proposed near the Westminster Road entrance. It is not expected to have an impact on the EC. None. 8 rather than engineered, appearance. Retaining walls 6 feet in height and taller, when necessary, shall be terraced and planted to blend with the landscape. 41 No grading, trenching, or tunneling should occur within the drip line of any trees or other existing features designated for preservation in the final Certificate of Appropriateness. Adequate tree protection fencing should be shown on, and coordinated throughout, the grading, landscaping and erosion and sediment control plans. Grading is shown close to the western property line in the vicinity of units 7-14 where a “tree line to remain” is shown. As illustrated, no on-site trees are expected to remain in this area. Some trees to remain are shown near the existing house and at the north corner of the property but species and sizes are not identified. Grading comes close to these trees, so tree protection fencing will be needed. Identify individual trees to remain on the plan, provide a conservation plan checklist on the plan, and provide appropriate tree protection fencing. 42 Areas designated for preservation in the final Certificate of Appropriateness should be clearly delineated and protected on the site prior to any grading activity on the site. This protection should remain in place until completion of the development of the site. 43 Preservation areas should be protected from storage or movement of heavy equipment within this area. 44 Natural drainage patterns (or to the extent required, new drainage patterns) should be incorporated into the finished site to the extent possible. Underground stormwater facilities are proposed at the front and back of the site. At the front of the site, this could impact plant quantity and location. See other landscape recommendations. 9 SUMMARY OF RECOMMENDATIONS Should the ARB wish to discuss this application, staff recommends the following as the primary points of discussion: 1. Landscaping along the EC, utilities in Open Space D and orientation/potential appearance of Block 1 buildings. 2. Visibility, orientation and potential appearance of Blocks 3, 4 and 5; future ARB review of Blocks 3, 4 and 5 3. Planting along the northern end of the western property line 4. Trees along interior roads Regarding the Initial Site Plan: Staff recommends that the ARB forward the following recommendations to the Agent for the Site Review Committee:  Regarding requirements to satisfy the design guidelines as per § 18-30.6.4(2), (3) and (5): 1. As per § 32.4.2.2(b)(3) and 30.6.4(c)(3) and EC Guideline 33, it is not clear that sufficient planting area is available along Georgetown Road and Road A to accommodate large trees, 2½” caliper at planting, spaced consistently at 40’ on center.  Regarding recommendations on the plan as it relates to the guidelines: None.  Regarding recommended conditions of initial plan approval: 1. A Certificate of Appropriateness is required prior to final site plan approval. 2. Provide planting area free of utilities and easements along the extension of Georgetown Road and Road A. Provide large trees 2½” caliper at planting, consistently spaced 40’ on center along interior roads. 3. Coordinate all sheets of the site plan regarding the three-board fence to remain along the EC and the power line to be moved underground. 4. Provide landscaping along the Barracks Road frontage to meet the EC guidelines requirements and to mitigate the back of the Block 1 buildings facing the EC. 5. Identify the plant species in the plant list. Increase plant sizes in the plant list to meet EC requirements. 6. Specify a dark, matte finish for the PVC fence. 7. Add the following note to the site and architectural plans: Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. 8. Provide perimeter parking lot trees for the Block 3 parking lot using large trees, 2½” caliper at planting, in a quantity equiva lent to 40’ on center spacing, plus one tree to meet the interior tree requirement. 9. Provide trees behind units 7-14 and along the western perimeter of Open Space A. 10. Add the following note to the site plan: All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant.  Regarding conditions to be satisfied prior to issuance of a grading permit: 1. Identify individual trees to remain on the plan, provide a conservation plan checklist on the plan, and provide appropriate tree protection fencing. 10 TABLE A This report is based on the following submittal items: Sheet # Drawing Name Drawing Date/Revision Date C1 Cover Sheet 1/21/14 C2 Proffers & Lot Regulations 1/21/14 C3 Existing Conditions & Demo Plan 1/21/14 C4 Site Overview 1/21/14 C5 Preliminary Site Plan and Utilities 1/21/14 C6 Preliminary Site Plan and Utilities 1/21/14 C7 Preliminary Grading Plan 1/21/14 C8 Preliminary Grading Plan 1/21/14 C9 Road and Waterline Plan Georgetown Rd. 1/21/14 C10 Road and Waterline Plan Georgetown Rd. 1/21/14 C11 Road and Waterline Plan Road A & Road Sections 1/21/14 C12 Road and Waterline Plan Bennington Rd. 1/21/14 C13 Road and Waterline Plan Road B 1/21/14 C14 Landscaping Plan (mislabeled as sheet C12) 1/21/14