Loading...
HomeMy WebLinkAboutWPO201900057 Plan - Revision 2023-02-171 1J VIA x 30" Geoweb Fill Front Cell w/ Topsoil for Planting Purposes Use Tamper Bar to E Consolidate In Each Cell Min 2" Setback Per 6" Cell Height 4-FT Fence Geogrid Reinforcement (Typ.) Refer to Wall Profile for Geogrid Type, Geogrid Min 6" Length (GL) and Location I � Non -Woven Filter Fabric WALL A S VDOT No. 57 Stone w/ 4-FT Tall Fence Fill Rear 2 Cells w/ No. 57 Stone For Drainage Retained Rd Profitt Road Townhouses North / A \ \ 1 W¢ephole soll Dctober 5, 2022 Tw so N 1 Drain to Do) ight �,�,Y Revised Retwall Exhibit . BW Soo 0 I 40' OC Spacing (Typ) Shimp Engineering, P.C. SiQ f? $ 8 " 1 N +VERT APPBox a95 r(2) `�" � � Extend Beyond Wall Face N wY Reinforced Fill e d �� Granular Soil / Tw 509 a VVV 4 1 20 LF CUSS 1 / \ BW 500 b ofO Compact to Min 95% RIP -RAP OVER \ 4" Dia. Drain Pip¢ MIRAFI 140N FABRIC \ Soil Botkfill Standard Proctor (See brain Detail) �N / $ TW 504 \ GL \N 14� ..•• O OW 494 \ Stone Leveling Pod r °iu mx. ra LaxEx N ""OfD � 6" Thick x 42" Wide a[ae � �•„ N \ \ TYPICAL RETAINING WALL CROSS SECTION ms (Not to Scale) 42 \�I..` p90 C 1 I N S TW 519/. • / 3 iW 514 •••• �g 1 B 4 TW __ S 1 / g \ i BW/' °" \\ BW a No. 57 Stone in Rear Topsoil in Front Cell Two (2) Cells % i \ Tw 51; Bw 50 Perforated (Typ.) JNNNNNNM 6 • a � \ � \ � rNNNNNNN ,_ w\: �,,� x �Is 8x8x ANrC�,� Scale: l" = 40 FT GEOWEB 3—CELL SECTION SITE PLAN 0 20 40 (Not to Scale) DRAWING INDEX Geoweb Cellular Confinement Retaining Wall System ti LrH o Proffit Road Townhomes North �y FL Albemarle County, Virginia heet No. pNc,���� / /%�CIRCEO GEOTECH 1 cal Site Plan Proffit Road Townhouses North 'i /�/ Circeo 5956 Buckland Mill Road 2 General Notes O GEngin Engineering, Albemarle County Virginia U ICHAEo' 0 12 0> Engineering, P.C.PCRoanoke, Virginia 2 379 3 Geoweb Details Lc. No' ® Phone: (540) 366-2379 4-5 Wall A - 5to. 0 to Sta. 312 Site Plan Adapted From The Revised Retwall Exhibit, ° �W Dated October 5, 2022, Prepared by Shimp Engineerning, P.C. Scale: 1" = 40 FT �sS $G Date: 12/OS/22 Project No. RW-2891 Site Plan For Illustrative Purposes. Approx. Scale: 1" = 40 FT ZONAL "` & Revision:I -- I Sheet 1 1 of 5 �NERAL NOTES: DESIGN PARAMETERS: 1 BUILDING CODES: 2018 VIRGINIA UNIFORM STATEWIDE BUILDING CODE (USBC) 1.0 STRIP VEGETATIVE AND ORGANIC SOIL FROM THE WALL 14.0 REINFORCED FILL SHALL CONSIST OF GRANULAR SOIL FILL AND 2018 INTERNATIONAL BUILDING CODE (IBC). AND GEOGRID ALIGNMENT. WITH USCS SOIL TYPES GP, GW, GM, GC, SW, SP, SM OR SC 2 WALL PROFILE IS BASED ON INTERPRETATION OF THE REVISED RETWALL 2.0 BENCH CUT ALL EXCAVATED SLOPES. WITH A MINIMUM ANGLE OF INTERNAL FRICTION, OF 28 DEGREES EXHIBIT, DATED OCTOBER 5, 2022, PREPARED BY SHIMP ENGINEERING, P.C. 3.0 DO NOT EXCAVATE BEYOND EXCAVATION LINES SHOWN AS OUTLINED IN DESIGN PARAMETERS - NOTE 6. 3 WALL DETAILS SHOWN ON THIS PLAN ARE FOR PRESTO GEOWEB GW30V6 ON PLAN UNLESS DIRECTED BY THE GEOTECHNICAL LOW PLASTICITY CLAYEY SAND (SC), SILT OR CLAY (ML-CL) CAN BE USED CELLULAR SECTIONS. ENGINEER TO REMOVE UNSUITABLE SOIL. SUBJECT TO APPROVAL BY THE GEOTECHNICAL ENGINEER. 4 ENGINEERING ANALYSIS BASED ON USE OF STRATAGRID 5GU60 GEOGRIDS. 4.0 CONTRACTOR SHALL ENSURE TEMPORARY EXCAVATIONS ARE STABLE MAXIMUM PARTICLE SHALL BE LIMITED TO 4 INCHES IN DIAMETER. OTHER COMPATIBLE GEOGRIDS MAY BE SUBSTITUTED WITH AND PROVIDE EXCAVATION SUPPORT IF NEEDED. THE FINE FRACTION (MINUS NO. 40 SIEVE) SHALL HAVE A MAXIMUM THE APPROVAL OF THE WALL DESIGN ENGINEER. 5.0 GEOTECHNICAL ENGINEER SHALL VERIFY FOUNDATION LIQUID LIMIT (LL) OF 40 AND A MAXIMUM PLASTICITY INDEX (PI) 5 FILTER FABRIC SHALL BE NON -WOVEN GEOTEXTILE SUCH AS MIRAFI 140N, SOILS AS BEING COMPETENT PER THE DESIGN PARAMETERS. OF 20. THE BACKFILL SHALL BE FREE OF DEBRIS AND ORGANIC MATTER. OR APPROVED EQUIVALENT. 6.0 LEVELING PAD SHALL CONSIST OF COMPACTED SAND, GRAVEL, HIGHLY EXPANSIVE SOILS (MH-CH) SHALL NOT BE USED IN THE 6 THE DESIGN OF THE GEOWEB CELLULAR CONFINEMENT RETAINING WALL OR COMBINATION AND SHALL BE A MINIMUM 6-INCH THICK REINFORCED FILL ZONE. A55UMES THE FOLLOWING PARAMETERS: LAYER WITH A MINIMUM WIDTH OF 42 INCHES. Ym• Moist FRICTION 7.0 A 4-INCH-DIAMETER SLOTTED HDPE DRAINAGE PIPE SHALL BE INSTALLED 15.0 REINFORCED FILL SHALL BE PLACED IN 6-INCH LIFTS AND SOIL SOIL UNIT WEIGHT ANGLE COHESION BEHIND THE WALL AND CONNECT TO WEEPHOLES INSTALLED AT COMPACTED TO A MINIMUM OF 95 % OF MAXIMUM STANDARD CONDITIONS Type (PCF) (DEG) (PSF) THE BASE OF THE WALL (40 FEET ON CENTER) AND EXTEND BEYOND PROCTOR DENSITY (ASTM D-698). COMPACTION TESTS SHALL REINFORCED FILL Granular or Low Plasticity Soil 120 28 0 THE FINAL GRADE TO DAYLIGHT (SEE DRAIN DETAIL). BE PERFORMED AS THE WALL IS INSTALLED. COMPACTION RETAINED SOIL SM-ML, SC-CL 120 28 0 WITHIN 3 FEET OF THE WALL SHALL BE LIMITED TO HAND- FOUNDATION SOIL SM-ML, SC-CL 115 28 100 8.0 DRAINAGE AGGREGATE AND GEOWEB INFILL SHALL CONSIST OF OPERATED EQUIPMENT. CLEAN ANGULAR GRAVEL, MEETING THE FOLLOWING GRADATION AS 16.0 A VIBRATORY PLATE TAMPER SHALL BE USED TO DEN51FY 7 SOIL STRENGTH PARAMETERS ARE BASED ON USE OF GRANULAR OR LOW DETERMINED IN ACCORDANCE WITH ASTM D-422. NO.57 STONE. COMPACTION TESTS CAN BE WAIVED PLASTICITY SOILIN THE REINFORCED FILL ZONE. ON -SITE GRANULAR SOIL WHERE NO.57 STONE IS USED AS REINFORCED BACKFILL. CAN BE USED FOR FILL PROVIDED THE SOIL IS PLACED SIEVE SIZE PERCENTAGE PA55ING 17.0 CONTRACTOR SHALL SLOPE SITE GRADES TO DIRECT SURFACE IN 6-INCH LIFTS AND EACH LIFT IS COMPACTED TO A MINIMUM OF 95% OF 1 INCH 100 RUNOFF AWAY FROM THE WALL AT END OF EACH DAY TO AVOID MAX. STANDARD PROCTOR DENSITY USING PORTABLE COMPACTION EQUIPMENT. 3/4 INCH 75-100 WATER DAMAGING THE WALL WHILE UNDER CONSTRUCTION. DO NOT USE HIGH PLASTICITY CLAY (CH) OR ELASTIC SILT (MH), NO.4 0-60 18.0 ANY SURFACE DRAINAGE FEATURES, FINISH GRADING, PAVEMENT, ROOTS OR TOPSOIL IN REINFORCED ZONE. NO. 40 0-50 OR TURF SHALL BE INSTALLED IMMEDIATELY AFTER WALL IS NO. 200 0-5 COMPLETED. ANY SOFT, SATURATED SOIL ENCOUNTERED IN SUBGRADE SHALL BE UNDERCUT 19.0 IF SITE AND SOIL CONDITIONS, WALL GEOMETRY, OR WALL AND REPLACED WITH CRUSHED STONE TO STABILIZE THE FOUNDATION 9.0 A NON -WOVEN FILTER FABRIC SHALL BE USED TO ENCAPSULATE LOADING ARE DIFFERENT THAN THE DRAWINGS AND THE DESIGN SUBGRADE OR AS DIRECTED BY THE GEOTECHNICAL ENGINEER. THE DRAINAGE AGGREGATE AND DRAIN PIPE TO PREVENT CLOGGING. PARAMETERS, THE CONTRACTOR MUST CONTACT THE WALL DESIGN ENGINEER PRIOR TO PROCEEDING WITH THE CONSTRUCTION OF WALL A - MAXIMUM WALL HEIGHT = 11.5 FEET (INCLUDING EMBEDMENT) 10.0 GEOGRIDS SHALL BE LAID HORIZONTALLY ON COMPACTED THE WALL. FRONT SLOPE = LEVEL TO MAX 2H:IV BACKFILL FOR THE REQUIRED GEOGRID LENGTH (GL) 20.0 DETAILS FOR FENCE POSTS AT THE TOP OF THE WALL ARE BACKSLOPE = LEVEL TO MAX 2H:IV NOTED ON THE WALL PROFILE. THE GEOGRID SHALL BE PROVIDED FOR PLACEMENT OF POSTS. SURCHARGE AT TOP OF WALL (VEHICLE TRAFFIC) = 100 PSF, WHERE APPLICABLE PLACED WITHIN ONE INCH OF THE FRONT FACE OF THE GEOWEB CELLULAR SECTION BELOW AND EXTEND HORIZONTALLY MIN FACTOR OF SAFETY (SLIDING) = 1.5 OVER COMPACTED FILL. MIN FACTOR OF SAFETY (OVERTURNING) = 2.0 11.0 GEOWEB CELLULAR UNITS SHALL HAVE DIMENSIONS MIN FACTOR OF SAFETY (BEARING CAPACITY) = 2.0 6 INCHES HIGH BY 30 INCHES DEEP (WHEN EXPANDED) BY DESIGN SOIL BEARING PRE55URE = 2,000 PSF [SEE NOTE ON WALL PROFILE] 8.67 FEET LONG AND SHALL BE WITHIN + 17 IN ANY DIMENSION. 12.0 A 2-INCH SETBACK PER GEOWEB SECTION SHALL BE MAINTAINED FOR Prof fit Road Townhomes North r`NNNN.':151ti5 .111ti5 ��pLTH OF Albemarle County, Virginia PROPER BATTER (I.E. 18.4 DEGREE CANT FROM VERTICAL). r.,n.n.nv`. Pr.r.r.r.r. �r.r.r.r.r. tY 9 nN•n•nN..;1.1 ;1 ;1 ;5 .;1.1 ;1 ;ti•5 r`NNNN.:111ti5.111ti5• O� CIRCEO GEOTECH �r•r•r•r•r•�r•r•r•r•r• 2" Setback � `�" ••1.1.1;ti;5.;1•};1;ti•5 � C� Circeo 13.0 STRETCHER FRAMES, J-PINS OR OTHER SUITABLE ANCHORS ,y 5956 Buckland Mill Road -•c:{:;::{:c:-:q:; -• = Geotechnical SHALL BE INSTALLED TO EXPAND THE GEOWEB SECTIONS (Typ.) "r{_ :i{' .r{_ ICHAEL R. C R 0 Y h Engineering, P.C. Roanoke, Virginia 24019 LiC. a PRIOR TO PLACEMENT OF FILL. 6° H .a No.021245 Phone: (540) 366-2379W GEOWEB SETBACK �'o /Z�S�ZZ .off Gti? Scale: N/A Project No. RW-2891 (Not to Scale) SSIONAL Date: 12/08/22 r.�•� Revision: I Sheet 1 2 of 5 LEVELING PAD DETAIL (Not to Scale) Reinforced Fill t" Dia. Slotted HDPE Drain Pipe v/ No. 57 Stone Encapsulated v/ Fitler Fabric foil Backfill Fence/Handrail Post Behind Wall Min 6" Min 6" Dia. Sleeve Fill Grout Around Post Cut Geogrid Around Sleeve Filter Fabric \ 4 FT Wide l.NNNNNN.I� J•J.J•MNNNN rNNNNN.�/`N I.NNNNJ�J`.I` J•NJ•J.NNJ•J� i I.NNNNNNN ti:i.ti.1. J•J.NMNMNM J•NNNNNNN f.f.f.f.f y.Yti K.• J•NNNNNNN I.NNNNNNN .f.J•1•J•r•. �.1.5.1.1.1.� v wwv �y�Y�AI %a%IG�A Reinforced Fill 6" Dia. Min FENCE POST DETAIL (Not to Scale) Weephole - 40 FT O.C. (Typical) Cut Opening Through Geoweb Stone Leveling Pad No. 57 Stone Op Lic.. No. 021245 / % V12r, c S's, NA WEEPHOLE DETAIL (Not to Scale) Reinforced Fill 4" Dia. Perforated Drain Pipe Wrapped w/ Non -Woven Filter Fabric Min 12" ' Geoweb GW30V6 Topsoil Open Joint (Weephole) DRAIN DETAIL at Max 40' O.C. (Not to Seale) Drain to Daylight Circeo 5956 Buekland Mill Road Geoteceerinhn Roanoke, Virginia 24019 Engineering, P C. 9 Phone:(540) 366-2379 Project No. I RW-2891 WALL A W, WALL A (Typical) - 4-FT Tall Fence TOW &L=10FT Crest 518 511 1 • •• �� • • • _ 1 _I___.___ • • • • __ ___,__��_________________ I w� wwl+_w�w�w�w�w�l�m �—���_• alwww�w�wwi�w�w��•�_ �����•�w��ww�w�w�www��_�_�_�_�_�_�_�_�_�_�_�__�•�_�_�_ 1: �•��egp���•� �llllllll�l��w� www�www�www�w�w�li�_�_ ���_�_�_w�w�w�w�w�w�w�w�ww w�w�www�w�w�w�ww 1. i --•— --- —_win_w�i1�L'✓iL••iww�__________waa�www�www�w�w�lwww�w�w�w�w�www�w�w�w�w�w�w�w�ww ,�www�w�` w�w�www�r�w�w� - 1 FT 1 500 498 . �1'�i_A_�_� . ...._�_�_w�www�w�w�w�w�www�w�w�w�w�www�w�w�w : • • .wa =============== e�P 1 =-492 • • : • • • • 1 " ® 490 Proposed Grade at Bottom of Wall — BOW = 494.0 - 488 Leveling Pad BOW = 492.5 (Low Point) 12 20 24 30 40 50 60 70 80 90 100 110 116 120 I I I Station (ft) I Drain Pipe to Daylight - 40 FT O.C. (Typical) I f GL = 8 FT iI f GL = 10 FT GL = 12 FT I. GL = 10 FT I LEGEND Use Granular or Low Plasticity Soil in Reinforced Fill Zone Albemarle nia 0 Presto Geoweb GW30V6 (6" Height x 30" Width) EQ Circeo 5956 Buckland Mill Road Geotechnical Leveling Pad (Min. 6" Thick Stone) _= Engineering, P.C. Roanoke, Virginia 24019 roc Top of Cap Unit RETAINING WALL A v ICHAEL R. C RC > Phone: 540 366-2379 Lic. No. 021245 I ( ) TOW Top of Wall (Excluding Cap Unit) .o Q Fax: (540) 904-6200 BOW Bottom of Wall (Including Embedment) Sta. 0 to Sta. 120 P �Z/8- H; 1"= 60 StratoGrid SGV60 Viewed From Front Face of Wall '0F 0 Scale: V: 1"= 1o10 ft. f+. Project No. RW-2891 SSIONAL �� Date: 12/08/22 J 0 4" Drain Pipe to n Soil Bearing Pressure = 2,000 ---------------- ---------------------------- -------------------- --------------iiii-- •------------------- -------- . iiii---- --__----- --- ---------------- - -------------------- =--- ------- • . • --- - ------- ------- i-- --- •— -� i-- Ii—���iiiiiliii—w iiliii�.iiii 1i�_�_r_�_�_�•��_�_�_��_�_�_��_�_�_�_�_�_�_�_�_�_�_!—.i_i�l� ii ii�liiii 1 1 1 1 1 1 - wadi iiii_ �7TTTTTTTTTTTTTT r_riiiiiiiiiiiiiii TTTT_T_T__T WALL A 4-FT To TOW 508.0 512 TOW 5 494 - t6" Thick Stone BOW 498.0 Vow__� Storm brain Under Wall A 492 BOW 496.0 Proposed &rode at Bottom of Wall Invert EL. 495.0 490 Leveling Pad BOW 494.0 1 1 brain Pipe to Daylight - 40 FT O.C. (Typical) 488 ril I I 11 1 160 I 180 •• I I I 1 I FT GL 12 FT i== iiii_i_i_iiiiiii_i_i_i_iiiis / • ii .iiiiiiiiiiiii��i�� i O 510.0 ; ii� iii-- .�iliiii iiii iii-- LU i_i_i_ii—��� iiiiiiiiir— �i--il�iiiliil�iliiiiiiii iiii iiii � iiii iiii iii 1�i_i_i_li_i_—_—il�iiilii�iiliiii _�_�_�_�__��_�_�_�_��_�_� _ • I�iiilii—•�il�iiili� ���—iiiaiJ•iiiiiiiiiii�' 1 512 -I�iiil���.—----f-l/r1i11�7 Fence a 1: i a w 16 j��—=��i�����'�_���.=gym— iBOW 510.5 � so 11 _ BOW 508.0 i--�- — �s a :. • • GL 1 FT 496 • ' 494 :. :.500.0 • ••1 492 1 1 Prop 11 1 •1' at Bottomof • i i ii 488 I • I ® m Station (ft) I Use Granular or Low Plasticity Soil Albemarle County, Virginia Proffit Road Townhomes North in Reinforced 1 • • Presto Geoweb • I ' / •_5956 ® Pad 6" Thick Stone) RETAINING • • Roanoke, Virginia 24019 . TOC Top of Cap Unit TOW Top of Wall (Excluding Cap Unit) BOW Bottom of Wall (Including Embedment) I I I 60 'StratoGrid SGU60 Viewed From Front Face of Wall &L C�eoqrid Length (ft) 0 4" brain Pipe to Daylight [besign Soil Bearing Pressure = 2,000 psf