HomeMy WebLinkAboutARB202300016 Review Comments Miscellaneous Submittal 2023-02-17SIGN REVIEW CHECKLIST WITH REFERENCES — Freestanding Signs
REF
CHECKLIST ITEM
NOTES
TYPE
❑
8.a
Monument signs are preferred to pole -mounted signs.
Using a monument sign
Pole signs may be considered if existing site conditions rule
out the ability to use a monument sign, and only when the pole
is in proportion to the sign cabinet or panel.
n/a
MATERIALS
❑
8.b
Materials used in both the sign and support structures should
be complementary.
Materials existing. No changes proposed
They should also support the aesthetics of the
building/complex being served by the sign.
❑
8.b
It is preferred that the base material match one of the primary
building materials
unless the sign design represents itself as a freestanding
element complementing the building.
COLORS
❑
4.e
Colors must be harmonious with each other.
Red, Blue, and White are harmonious
Colors must not clash with other elements on the site, both
when viewed in daylight and at night.
Landscaping buffers sign from other built elements
and the buildings. The colors of the sign are not
expected to clash with the site.
Overly intense color, (such as dayglo or fluorescent colors),
are prohibited.
Colors are not overly intense
Use of three colors or less Black and white are colors.
4 colors, although the grey and white are in the same
spectrum
Updated:08-19-2019
REF
CHECKLIST ITEM
NOTES
Additional colors may be approved if they contribute to a
4 colors, although the grey and white are in the same
balanced/unified sign design.
spectrum
❑
9.c
For raceway -mounted channel letters, raceways shall match
n/a
the wall color.
LANDSCAPING
❑
8. d
Use ground cover, shrubs and/or trees to integrate freestanding
Landscaping is existing.
signs into the overall site landscape
Use plants from the Albemarle County Recommended Plants
List.
SCALE AND SIZE
❑
Ah
Signs may not exceed the size, height and setback
Size approved by Zoning.
requirements as outlined in Section 4.15 of the Albemarle
County Zoning Ordinance (unless the sign has received a
variance).
❑
8. c
The structure of a monument sign shall not overwhelm the
Scale and size existing.
sign.
The structure and the sign that it supports must be in
Scale and size existing.
proportion to each other.
SIGN LETTERING AND TYPEFACE
❑
Ad
Lettering should be in proportion (font size and typeface style)
Letters are appropriately scaled and in proportion to
to the sign and the building.
sign face.
Use of three typefaces or less.
yes
Additional typefaces may be approved if they contribute to a
n/a
balanced, legible, unified sign design.
❑
8.e.iv
If outlines of letters are proposed, the outline width must be in
No outlining
proportion to the letter width.
Updated: 08-19-2019
REF
CHECKLIST ITEM
I NOTES
An outline width of 1/8" is the appropriate sign dimension.
No outlining
TRADEMARKS, CORPORATE LOGOS, AND GRAPHICS
❑
4.f
The ARB may require that the color and scale of standard
Logo is contained within the sign lettering and is an
templates for trademarks, service marks, corporate logos and
integral part of the sign.
graphics be modified.
When used, trademarks, service marks, corporate logos and/or
graphics should be incorporated as an integral part of the
overall sign.
LIGHTING
❑
8.ed
External illumination (or no illumination) is preferred for
No illumination
freestanding signs.
❑
5.f
Any internal illumination is considered to contribute to visual
No illumination
clutter and will be limited.
The design will be evaluated for size, balance, complexity, and
distance from and relationship to the Entrance Corridor.
❑
5. a
External Illumination should be shielded and not create glare.
No new lighting proposed.
Lighting should be aimed so as not to project illumination
beyond the sign.
All external light sources shall be white.
❑
8.e.#
Ground mounted lighting should be shielded by landscaping so
that it is not visible from any adjacent property or right-of-
way.
❑
5.h
An exposed light source that forms the body of a sign, (such as
exposed neon signs), shall not be used.
Updated: 08-19-2019
REF
CHECKLIST ITEM
NOTES
❑
5.g
All illumination shall be non -blinking.
No new lighting proposed.
❑
5.c
External illumination (or no illumination) is preferred for
approved graphics/logos;
internal illumination may be considered for approval.
❑
8.e.iv
Cabinet signs shall have a non -illuminated background, or an
n/a
opaque (zero light transmission) background.
Cabinet signs shall be constructed such that no light spills
n/a
outward from the top, bottom, sides or back.
❑
8.e.#i
Channel letters (although not likely appropriate for
n/a
freestanding signs) with translucent faces shall be constructed
such that no light spills outward from the top, bottom, sides or
back.
If back -lit (halo -lit), the faces and returns of channel letters
n/a
shall be opaque.
ARB ACTIONS
❑
(ARB
Billboards are inappropriate for the Entrance Corridors.
n/a
Action
Memo:
1/19/10)
No refacing design (no combination of colors, images, text and
n/a
layout) will make the billboard an appropriate appearance.
Existing billboards may not increase in size and may not
n/a
include modifications beyond the existing sign surface.
No new illumination of any kind may be added to the
n/a
billboard.
Updated: 08-19-2019
REF
CHECKLIST ITEM
NOTES
❑
(ARB
Reader boards shall have an opaque background.
n/a
Action
Memo:
1/19/10)
Only the letters may be illuminated, but illumination is not
n/a
required.
Reader boards shall not exceed 40% of the size of the overall
n/a
sign face.
The background color of the reader board shall be black or
n/a
some other color already on the sign face.
Construction of the reader board shall be integral with the
n/a
main sign.
The track holding the letters shall have minimal visual impact.
n/a
❑
(A"
Action
Syn4we.:,, ....., i for if ,
n/a
ee aeeeptable signs mounted a solid
f , , bleev if iim fled to ,, flat
u f ee ieh eenerete and use as
Memo:
5/4/09)
(Deleted
Styr f am backing is fie. , eptahie
n/a
Following
8/19/19
ARB
action)
(ARB
Synthetic stucco can be used for signs regardless of the
Existing monument sign.
Action
material to which it is attached. However, the condition where
Memo
the sign meets the ground must be addressed. 8" of a durable
8/19/19)
solid material (not EIFS) must be provided at the base unless
the sin is located in a landscape bed whose design avoids
Updated:08-19-2019
REF
CHECKLIST ITEM
NOTES
potential maintenance issues of EIFS at the ground.
❑
Action on ARB-
Red acrylic #2283 has been determined to be an
Proposing Red #2793 which is acceptable.
P(BP)-2001-12
inappropriate color for signs.
Wood Grill
Pantone color match for 2283 is 485C. Red #2793
has been approved as an acceptable substitute.
Pantone color match for 2793 is 187C. See below.
12/21/15 action on
Generally, for signs in the Entrance Corridors, red 485
n/a
ARB 2015-114 &
may be acceptable on a case -by -case basis as a secondary
-115 Shell Signs
color.
❑
(ARB
Scale, location, proximity to existing building(s), quality of
Sign is existing.
Action
sign materials, and sign height and other pre-existing
Memo:
conditions determine how much planting is required at the
10/5/09)
base of the freestanding sign.
❑
Deleted
following
ifLED ligWing i the drawing Th_-
n/a
proposed sign must state
6/3/19
„ i ilia_ i (nia) neen
ARB
action
p
❑
Internal LED for the gas pricing: Daytime intensity limited to
n/a
70% of maximum intensity; Nighttime intensity limited to
16% of maximum intensity with automatic dimming at dusk.
ARB
Visual clutter resulting from adjacency, for example at the
n/a
Action
Hardee's locations, is a reasonable basis for not allowing
Memo:
illumination of the graphic.
5/7/12
Updated: 08-19-2019