HomeMy WebLinkAboutSE202300009 Plan - Approved 2023-03-07 (3)CONTINUOUS VAPOR/
AIR BARRIER, MIN. R49
INSULATION
1/2" GYPSUM BOARD —
CEILING AND WALL
FINISH
40 YEAR DIMENSIONAL SHINGLES ON ONE
LAYER OF 15" FELT, 1/2' OSB SHEATHING ON 2x10
RAFTERS - USE '14' CLIPS IF SPACING 24' O.G.
BAFFLE FOR VENTING
Q' J, SILL PLATE WITH OPENING FOR
EA REQUIRED VENTING
GSM GUTTERS AND DOWNSPOUTS
2x ENGINEERED OR CEMENTITIOUS
FRIEZE BOARD WITH DRIP EDGE
Ix SOFFIT VENTED PER CODE
PAINTED HARDIE SIDING OR HARDIE
SHINGLE OVER WATERPROOFING OVER
FINISH FLOOR STRUCTURAL SHEATHING, 2x6 WOOD
OVER PLYWOOD STUDS AT III O.G., R-19 INSULATION,
5U5FLOOR INTERIOR WALL FINISH, DOUBLE PLATE
AT TOP WITH SILL PLATE AT BOTTOM
14' TJI'S AT 24' O.C.
PAINTED HARDIE SIDING OR HARDIE
SHINGLE OVER WATERPROOFING OVER
STRUCTURAL SHEATHING, 2x(o WOOD
STUDS AT III O.G., R-19 INSULATION, 0
INTERIOR WALL FINISH, DOUBLE PLATE -0
AT TOP WITH SILL PLATE AT BOTTOM
ANCHOR BOLTS
PER CODE � GSM FLASHING
PER
GONG. SLAB - SLOPE
1/6' PER FOOT 1 SLOPE GRADE DOWN
TOWARDS FRONT l l// AWAY FROM STRUCTURE
4 1/4' PER FOOT MIN.
° ° a —III III —I
. ° III —III III
III III III I I
-1 I III
L ..III III —III III III—
I� III=1 I I� I I —I I I
- z W 111—III III 111-
I 11111=111I III III —I I1=1I III I1=1I I1=1I I1=1I
-III III —MI III 111—I III I I Ii I III I i—i I I a
,iT-III-III, ,Ir III=III-111 III=III=III=III=III III =III— Z
I � 0 111-111 111-
1=1
0 w w =M=1
'iI=III=III=III=III a III—III=�
o 11-11'
rts w
24' WIDE x 12' DEEP -
—III=III=III=11 III=III=11 rol=
I=111;
III=
CONCRETE FOOTING I—III-1I1=1I I1=1I1=
I1=1I1=1I1=1I
I p =1I
= I1=
WITH STEEL REBARS _=1I1=1I
TO BEAR ON il� III-_ • ,IIIII
_ __- _
UNDISTURBED SOIL III -III— • °;•alll-III,„-_-_;
m m III
PROPOSED WALL SECTION
TOP PLAT
BOTTOM OF
ROOF RAFTERS
SUBFLOORR�
TOP PLATE
BOTTOM OF
ROOF RAFTERS
TOP OF
GARAGE sLa6
AT HIGHEST
POINT (BACK
OF GARAGE)
SCALE: 1/2" = Y-0"
0 6" 1' 2'
u
ro
61
r-
N
N
�
O
LITTLE YORK HEIGHTS
50' R/W
PROPOSED SITE PLAN
PROJECT TEAM
SHEET INDEX
CLIENTS: MATT and ALI CADDENHEAD A0.1 COVER SHEET, SITE PLAN and WALL SECTION
8690 LITTLE YORK HEIGHTS
GREENWOOD, VIRGINIA 22943 Al .1 PROPOSED MAIN and UPPER FLOOR PLANS
Al .2 PROPOSED ROOF PLAN
CONTACT: MATT CADDENHEAD
T: 443-306-6948 A2.1 PROPOSED EXTERIOR ELEVATIONS
EMAIL: MCADDENHEADI@GMAIL.COM
ARCHITECT: SCOTT WEISS, ARCHITECT
104C MELBOURNE PARK CIRCLE
CHARLOTTESVILLE, VIRGINIA 22901
CONTACT: SCOTT WEISS
T: 434.242.9288
E: SCOTT@WEISS-ARCH.COM
WWW.WEISS-ARCH.COM
GENERAL CONTRACTOR:
I
I
I
I I
25'-0'
46'-6'
® a I I
2-CAR
--,''
GARAGE / -� I
STUDIO
I
_ I I
LU
J► 25'-o"
T FRONT SETBACK
/ L=90°00'15'
R=50.00'
T =50.00'
L=1854'
SCALE: 1/16"= 1'-0"
0 4 8 16'
SCOTT
WEISS
ARCHITECT
104C MELBOURNE PARK CIRCLE
CHARLOTTESVILLE, VIRGINIA22901
T: 434.242.9288
E: SCOTT@WEISS-ARCH.COM
All drawings and copies thereof
are instruments of service and
as such remain the property of
the Architect. They are to be
used only with respect to this
project. With the exception of
one complete set for each
party to the contract, all copies
are to be returned or suitably
accounted for to the Architect
upon completion of the bidding
and upon completion of the
project.
LU
Q
}
U
—
O
Z
Z
LU
~
C)
V
Z
v /
—
LU
>
Z
O
0
.
LU
N
Q
LU
LU
O
'LUV
I
O
<
Z
LU
z
'Q
Q
LU
>v
Q
LU
W
Q
Z
U
c�
COVER SHEET
SITE PLAN
and
WALL SECTION
DATE: ISSUE:
10.4.2021
PRELIMINARY
11.4.2021
REVISED
1 1.6.2021
PERMIT SET
1 1.15.2021
PERMIT SET
12.5.2022
REVISIONS
AOO I
4 0
A2.1 n
LEFT SIDE
ELEVATION
BACK ELEVATION
3
A2.1
25'-0'
9 -2 1- l -II
4 _T" 4'_1'
THREE 2650
DBL. HUNG CL
a
STORAGE
C
2-CAR GARAGE / STUDIO
4'-4 1/2'
24'-0' x 24'-6'
STORAGE
® COVERED 3°Tm T.G.
STOOP FRENDOOR
CL
® r
9@8� CARRAIGE-STYLE S9892 CARRAIGE-STYLE
GARAGE DOOR GARAGE DOOR
M
1r—Tr—lT—�— 1— 11 hill
_.1 — Ti- — lT —--lT--1
IIII II II II III II II IIII II II II III II II IIII
JJ11_ --]L-JL JL JL �� �� AIL JL JL JL JL -JJI-L
� �,Ir —1� —1� -IT-- �� --r1r -1� -1� —IT— -11-- -11-1- �
BRACKET -SUPPORTED TRELLIS ABOVE
7'-0' II'-0' 1'-0"
1
A2.1
FRONT ELEVATION
LOWER LEVEL FLOOR PLAN
C!Qllf'4Y
J
UP 16R
3'-6'
i
2
A2.1
RIGHT SIDE
ELEVATION
0
SCALE: 1 /4" = 1'-0'
0 1 2 4'
BACK ELEVATION
3
A2.1
25'-0'
6'-4' 1- 12'-4' 6 -4
z SHOWER
m
Ott D o
N v
Z
M=
c
4 0
A2.1 n
LEFT SIDE
ELEVATION
6'-2'
THREE 2642 FIXED
HIGH WINDOWS
El
r
W.I.C.
9I LU C
N
L
EQ. j. EQ.
o BATH � CL CL.
w
a " ENTRY
BED ALCOVE 32192 T.G.
CAN BE A SEPARATE ROOM FRENCH
PANTRY 6' 61161 DOOR 6'
e 0
26�m — _
POCKET
— — — — — — — — — —
3'-10" LI
2'-6 12' — II 4' — — — — — 4'-1
REF. fY
�q
a
w
LU
3062ISLAND
u
w
Z
w
L
r
I
L
r
CLEAR
L
i\v
Q
I'-31/2' 6
GREAT ROOM
24'-0' x 13'-l' INCLUDING KITCHENETTE
m u THREE 265@ DBL. HUNG WITH THREE
2616 FIXED TRANSOMS ABOVE
II II II II CEIIIII II II
12'-6'
UPPER LEVEL FLOOR PLAN
BRACKET
TRELLIS
1
A2.1
FRONT ELEVATION
12'-C6'
N
STOOP
DN I6R _
2
A2.1
RIGHT SIDE
ELEVATION
01
SCALE: 1 /4" = 1'-0"
0 1 2 4'
S C 0 T T
WEISS
ARCHITECT
104C MELBOURNE PARK CIRCLE
CHARLOTTESVILLE, VIRGINIA 22901
T: 434.242.9288
E: SCOTTQWEISS-ARCH.COM
All drawings and copies thereof
are instruments of service and
as such remain the property of
the Architect. They are to be
used only with respect to this
project. With the exception of
one complete set for each
party to the contract, all copies
are to be returned or suitably
accounted for to the Architect
upon completion of the bidding
and upon completion of the
project.
N
w
Q
U
—
O
7
L
Z
�
UJ
—
~
C
Z
v ,
—
0
W
Z
O
U
Q
LJJ
Q
C/)
Q
LULU
(D
=
O
Q
>
Q
W
Z
C)
LLJ
>(D
Q
LU
LU
Z
U
c�
PROPOSED
MAIN and
UPPER LEVEL
FLOOR PLANS
DATE: ISSUE:
10.4.2021 PRELIMINARY
11.6.2021 PERMIT
11.15.2021 PERMIT SET
12.5.2022 REVISIONS
Al 01
BACK ELEVATION
3
A2.1
25'-0'
I I
I
I
I
I
I
I
I
I
I
I
I
I
BELOW A2.1
I
RIGHT SIDE
S P S O E ELEVATION
4 0 0:12 a: I:
A2.1 (P
I
LEFT SIDE
ELEVATION
I
I
I
SLOPE
I
I
I
I
I
I
I
I
I
I I
BRACKET -SUPPORTED TRELLIS BELOW
1
A2.1
FRONT ELEVATION
ROOF PLAN
SCALE: 1 /4" = 1'-0"
0 1 2 4'
SCOTT
WEISS
ARCHITECT
104C MELBOURNE PARK CIRCLE
CHARLOTTESVILLE, VIRGINIA 22901
T: 434.242.9288
E: SCOTTQWEISS-ARCH.COM
All drawings and copies thereof
are instruments of service and
as such remain the property of
the Architect. They are to be
used only with respect to this
project. With the exception of
one complete set for each
party to the contract, all copies
are to be returned or suitably
accounted for to the Architect
upon completion of the bidding
and upon completion of the
project.
U
Q
U
—
o
Z
Z
w
Z
o
v ♦
_
0
W
Z
O
Q
•
LJJ
N
LL
O
w
=
O
<
Z
Q
W
Z
0
w
>D
>
C)
Lu
Lu
Z
c)
U
PROPOSED
ROOF PLAN
DATE:
ISSUE:
10.4.2021
PRELIMINARY
11.6.2021
PERMIT SET
11.15.2021
PERMIT SET
12.5.2022
REVISIONS
Al 02
UPPER LEVEL
FINISH CEILING
HARDIE SHINGLE
SIDING
40 YEAR
DIMENSIONAL
SHINGLES
HARDIE SHINGLE
SIDING
WOOD TRIM
UPPER LEVEL
------------- -- -
FINI5H CEILING
BRACKET-
SUPPORTED
LOFT LEVEL_ TRELLIS LOFT LEVELFINISH FLOOR
� FINISH FLOOR
MAIN LEVEL MAIN LEVEL
----- -- ----- -----— — — — — — — - -- -
FINI5H CEILING FINISH CEILING
— PAINTED WOOD
STAIRS AND
RAILINGS
MAIN LEVEL
FINISH FLOOR
PROPOSED FRONT EXTERIOR ELEVATION SCALE: 1/4"= V-0°
M=06PENE019
0 1 2 4'
PROPOSED BACK EXTERIOR ELEVATION
SCALE: 1 /4" = 1'-0"
0 1 2 4'
HARDIE HORIZ.
SIDING
PAINTED WOOD
STAIRS AND
RAILINGS
— — — MAIN LEVEL
FINISH FLOOR
1<
2 PROPOSED RIGHT SIDE EXTERIOR ELEVATION SCALE: 1/4"=V-0°
0 1 2 4'
PROPOSED LEFT SIDE EXTERIOR ELEVATION
40 YEAR
DIMENSIONAL
SHINGLES
HARDIE SHINGLE
SIDING
WOOD TRIM
STANDING SEAM
METAL PORCH
ROOF
BRACKET -
SUPPORTED
TRELLIS
HARDIE HORIZ.
SIDING
SCALE: 1/4"= l'-0"
0 1 2 4'
SCOTT
WEISS
ARCHITECT
104C MELBOURNE PARK CIRCLE
CHARLOTTESVILLE, VIRGINIA22901
T: 434.242.9288
E: SCOTTQWEISS-ARCH.COM
All drawings and copies thereof
are instruments of service and
as such remain the property of
the Architect. They are to be
used only with respect to this
project. With the exception of
one complete set for each
party to the contract, all copies
are to be returned or suitably
accounted for to the Architect
upon completion of the bidding
and upon completion of the
project.
LLj
Q
U
-
O
z
z
W
Q
V
Z
cry
o
w
>
z
O
U
I
w
cry
LU
O
w
=
O
Z
3
Q
w
z
0
w
3:
C)
w
w
z
C)
U
PROPOSED
EXTERIOR
ELEVATIONS
DATE: ISSUE:
10.4.2021 PRELIMINARY
1 1.15.2021 PERMIT SET
12.5.2022 REVISIONS
A201