HomeMy WebLinkAboutSDP202300019 Presentation Major Amendment, Final Site Plan 2023-03-13North America Office
Mole in U.SA AcouSfiblok, Inc.
6900
terbay
I O ■ ® Phone: 813-9 Boulevard
/7) 1'KlI Tampa, FL 33616 USA
All U.S. Materials Phone: 813-980-1400
Fax
653
wawa 3ustibl k.c
� quieting the world � www.acoustiblok.com
a NASA Spinoff listed company 1uu� Kecyaaoie sales@acoustiblok.com
This MANU-SPEC® utilizes the Construction Specifications Institute (CSI) Project Resource Manual (PRM)
including MasterFiormatT , SectionFormatTM and PageFormatTM. A MANU-SPEC is a manufacturer -specific
proprietary product specification using the proprietary method of specifying applicable to project specifications and
master guide specifications. Optional text is indicated by brackets [ ]; delete optional text in final copy of
specification. Specifier Notes typically precede specification text; delete notes in final copy of specification.
Trade/brand names with appropriate symbols typically are used in Specifier Notes; symbols are not used in
specification text. Metric conversion, where used, is soft metric conversion.
This MANU-SPEC specifies an outdoor sound isolation fence membrane. These products are manufactured by
Acoustiblok, Inc. Revise MANU-SPEC section number and title below to suit project requirements, specification
practices and section content. Refer to CSI MasterFormatTM for other section numbers and titles.
SECTION 09 80 00
ACOUSTIC TREATMENT
PART 1 GENERAL
1.01 SUMMARY
A. Section Includes:
Sound isolation fence membrane, for chain link fence and or metal frame structures...
Specifier Note: Article below may be omitted when specifying manufacturers proprietary products and recommended installation. Retain
Reference Article when specifying products and installation by an industry reference standard. If retained, list standard(s) referenced in
this section. Indicate issuing authority name, acronym, standard designation and title. Establish policy for indicating edition date of
standard referenced. Conditions of the Contract or Section 01 42 19 - Reference Standards may establish the edition date of standards.
This article does not require compliance with the standard but is merely a listing of references used. Article below should list only those
industry standards referenced in this section. Retain only those reference standards to be used within the text of this Section. Add and
delete as required for specific project.
1.02 REFERENCES
A. ASTM International
1. ASTM C423 Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation
Room Method.
2. ASTM D3273 Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an
Environmental Chamber.
3. ASTM D3274 Standard Test Method for Evaluating Degree of Surface Disfigurement of Paint Films by Microbial
(Fungal or Algal) Growth or Soil and Dirt Accumulation.
4. ASTM E90-09 (2016) Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of
Building Partitions and Elements.
5. ASTM E413-16 Classification for Rating Sound Insulation.
Specifier Note: Article below includes submittal of relevant data to be furnished by Contractor, either before, during or after construction.
Coordinate this article with Architect's and Contractors duties and responsibilities in Conditions of the Contract and Section [01 33 00 -
Submittals Procedures].
1.03 SUBMITTALS
A. General: Submit listed submittals in accordance with Conditions of the Contract and Section [01 33 00 - Submittal
Procedures] [ 1.
B. Product Data: Submit product data, including manufacturer=s SPEC -DATA® sheet, for specified products.
C. Samples: Submit 8 inch x 10-inch (203 x 254 mm) samples of each product specified.
D. Quality Control Submittals:
W Avalon LLC C 11,QW016 Pages 1 of 3
Manufacturer's Instructions: Manufacturer's installation instructions.
Specifier Note: Article below should include prerequisites, standards, limitations and criteria which establish an overall level of quality
for products and workmanship for this section. Coordinate article below with Division 01 Quality Assurance Section.
1.04 QUALITY ASSURANCE
A. Regulatory Requirements: In accordance with Section [01 41 00 - Regulatory Requirements]
B. Installation: In accordance with manufacturer requirements.
1.05 DELIVERY, STORAGE & HANDLING
A. General: Comply with Section [01 61 00 - Common Product Requirements] [_�.
B. Delivery: Deliver materials in manufacturer's original, unopened, undamaged containers with identification labels intact.
C. Storage and Protection: Store materials protected from exposure to harmful environmental conditions and at temperature
and humidity conditions recommended by the manufacturer.
PART 2 PRODUCTS
Specifier Note: Retain article below for proprietary method specification. Add product attributes, performance characteristics, material
standards, and descriptions as applicable. Use of such phrases as "or equal," "or approved equal" or similar phrases may cause
ambiguity in specifications. Such phrases require verification (procedural, legal and regulatory) and assignment of responsibility for
determining "or equal" products.
2.01 ACOUSTIC TREATMENT
Specifier Note: Paragraph below is an addition to CSI SectionFormat and a supplement to MANU-SPEC. Retain or delete paragraph
below per project requirements and specifier's practice.
A. Manufacturer: Acoustiblok, Inc.
Contact: 6900 Interbay Boulevard, Tampa, FL 33616; Phone: (813) 980-1400; Fax: (813) 849-6347; E-mail:
salesAacoustiblok.com; website: www.acoustiblok.com. Technical Contact: shawn(dlacoustiblok.com
2.02 MATERIALS
Specifier Note: Retain products below to conform to project requirements. If more than one product is retained, create designators and
coordinate with drawings.
A. AF-6 (Acoustifence). Sound Isolation fence membrane:
1. Thickness: 0.125" t 0.03" (3 mm t 0.76 mm)
2. Weight: 1 psf (4.89 kg/m2)
3. Heat tolerance: 190°f (87.77°) for 7 days, less than 1% shrinkage with zero deformations.
4. Freeze tolerance: -0°f (-17°c). Do not unroll or flex frozen material. Properties not affected by freeze/thaw cycles.
5. Grommeted Edges: Horizontal Sections- 8" o.c. (Top), 6" o.c. (Sides), 26" o.c. pair sets 6" from the bottom, Vertical
Sections- 8" o.c. (Top), 6" o.c. (Sides), 26" o.c. pair sets 6" from the bottom. Custom spacing upon request.
6. Acoustical Properties:
a. Sound transmission coefficient (STC) of 28 when tested in accordance with ASTM E90-09 (2016) and E413-16.
7. Fungal Growth: Rating of 10, no fungal or algal growth, no visible disfigurement when tested in accordance with ASTM
D3273 and D3274.
8. Tensile Strength: Up to 510 psi (3516 kPa) when tested in accordance with ASTM D5034.
9. Color: Black or Green
10. Barium free
11. UV tolerant
B. AF-6i & AF-8i (Acoustffence). Sound Isolation fence membrane:
1. Thickness: 0.120" t 0.03" (2.5 mm t 0.76 mm)
2. Weight: 1 psf (4.89 kg/m2)
3. Grommeted Edges: Horizontal Sections- 8" o.c. (Top), 6" o.c. (Sides), 26" o.c. pair sets 6" from the bottom, Vertical
Sections- 8" o.c. (Top), 6" o.c. (Sides), 26" o.c. pair sets 6" from the bottom. Custom spacing upon request.
4. Acoustical Properties:
a. Sound transmission coefficient (STC) of 27 when tested in accordance with ASTM E90-09 (2016) and E413-16.
U Avalon LLC 0 O=32021 Pages 2 of 3
5. Fungal Growth: Rating of 10, no fungal or algal growth, no visible disfigurement when tested in accordance with ASTM
D3273 and D3274.
6. Tensile Strength: Up to 1100 psi (3516 kPa) when tested in accordance with ASTM D5034.
7. Color: Black ONLY!
8. Barium free
9. UV tolerant
C. AF-8iH (Acoustifence). Sound Isolation fence membrane:
1. Thickness: 0.375" t 0.03" (9.5 mm t 0.76 mm)
2. Weight: 1.5 psf (7.33 kg/m2)
3. Grommeted Edges: Horizontal Sections- 8" o.c. (Top), 6" o.c. (Sides), 26" o.c. pair sets 6" from the bottom, Vertical
Sections- 8" o.c. (Top), 6" o.c. (Sides), 26" o.c. pair sets 6" from the bottom. Custom spacing upon request.
4. Acoustical Properties:
a. Sound transmission coefficient (STC) of not less than 30 when tested in accordance with ASTM E90-09 (2016)
and E413-16.
5. Fungal Growth: Rating of 10, no fungal or algal growth, no visible disfigurement when tested in accordance with ASTM
D3273 and D3274.
6. Tensile Strength: up to 1100 psi (3516 kPa) when tested in accordance with ASTM D5034.
7. Color: Black ONLY!
8. Barium free
9. UV tolerant
2.03 ACCESSORIES
Specifier Note: Retain accessories below to conform to project requirements.
A. Fasteners: 14" Stainless Steel Ties, 2501b rating, included with membrane purchase
B. Grommet Plugs: push snap plugs to fill grommet holes, not included, must be purchased
2.04 PRODUCT SUBSTITUTIONS
A. No substitutions permitted.
PART 3 EXECUTION
Specifier Note: Paragraph below is an addition to CSI SectionFormat and a supplement to MANU-SPEC. Retain or delete paragraph
below per project requirements and specifier's practice.
3.01 MANUFACTURERS INSTRUCTIONS
A. Compliance: Comply with manufacturers product data, including product technical bulletins, product catalog installation
instructions and product carton instructions for installation.
3.02 EXAMINATION
A. Site Verification of Conditions: Verify that substrate conditions, for substrates previously installed under other sections, are
acceptable for product installation in accordance with manufacturer's instructions.
3.03 CLEANUP
A. Proceed in accordance with Section [01 74 23 - Final Cleaning] [
B. Upon completion and verification of performance of installation, remove surplus materials, excess materials, rubbish, tools
and equipment.
END OF SECTION
Page 3of3
W Avalon LLC ® 11/23/2016