HomeMy WebLinkAboutSDP202300004 Plan - Approved 2023-03-22LEGEND
EXISTING
NEW
DESCRIPTION
BENCHMARK
SITE PROPERTY LINE
ADJACENT PROPERTY LINE
BUILDING SETBACK
PARKING SETBACK
0
10
PARKING COUNT
- -510- -
10
INDEX CONTOUR
---508---
12-
INTERVAL CONTOUR
311.5 x
+t
SPOT ELEVATION
311.5 TC x
SOTC SWL
+t t +t t
TOP OF CURB/BOTTOM OF CURB ELEVATION
311.5 TW x
+t t� w
TOP OF WALL ELEVATION
311.5 B W x
smw
+�
BOTTOM OF WALL ELEVATION
. -
STREAM
STREAM BUFFER
100 YEAR FLOODPLAIN
BUILDING
RETAINING WALL
RETAINING WALL HATCH
°
RAILING
STAIRS
EDGE OF PAVEMENT
ROAD CENTERLINE
FRONT OF CURB
BACK OF CURB
CG-12 TRUNCATED DOME
SIDEWALK
&
BIKE PARKING
HANDICAP ACCESSIBLE AISLE
HANDICAP PARKING
CROSSWALK
CONCRETE
mow
ASPHALT
RIPRAP
EC-2 MATTING
EC-3 MATTING
-
WETLAND
TREELINE
X
X
FENCE
-0-
-0-
UTILITY POLE
O
m
GUY WIRE
OHu
OHu
OVERHEAD UTILITY
ucu
UGu
UNDERGROUND UTILITY
OHE
OVERHEAD ELECTRIC
uce
UNDERGROUND ELECTRIC
ro
FIBER OPTIC
STORM STRUCTURE NOMENCLATURE
®
STORM MANHOLE
q ®
Q
DROP INLET (CAST INPLACE/PRECAST)
STORM SEWER PIPES
RD
RD
ROOF DRAIN
®
SANITARY STRUCTURE NOMENCLATURE
®
SANITARY MANHOLE
SANITARY SEWER MAIN
S
S
SANITARY SEWER LATERAL
W
W
WATER LINE
ws
ws
WATER SERVICE LINE
0 O
® O
WATER METER (WM>1",WM<1")
®
®
WATER METER VALVE
FHA
FIRE HYDRANT
AFHA
FDC
A FDC
FIRE DEPARTMENT CONNECTION
GAS
GAS
GAS LINE
EASEMENTS
CONSTRUCTION/GRADING
-.-
-.- -
ACCESS
- - - -
- - - -
SIGHT DISTANCE
UTILITY
- - _
STORMWATER
DRAINAGE
SANITARY
WATERLINE
- . - -
-
GASLINE
OWNER/DEVELOPER
WP RICHMOND ROAD, LLC (both parcels)
224 14 ST NW
Charlottesville VA, 22902
ZONING
Highway Commercial
Entrance Corridor (EC)
DISTRICT
Scottsville Magisterial District
BUILDING STANDARDS
Per Albemarle County Zoning Section 4.20, setbacks are provided as follows:
Front Minimum: 10' from right-of-way or edge of sidewalk
Front Maximum: No maximum setback on any lot, including a corner lot, abutting a principal arterial highway or interstate
Parking and Loading: 10' from any public right-of-way
Side and Rear: Adjacent to commercial or industrial zoning, buildings shall be separated in accordance with current building code
SOURCE OF TITLE
INST. # 202200000344 DB 688 P625 (plat) (parcel 794P (2.562 acres))
INST. # 202200000344 DB 492 P76 (plat) (parcel 794A (4.029 acres))
SOURCE OF BOUNDARY AND TOPOGRAPHY
Boundary and Topographic Information was compiled from a Topographic Survey prepared by Foresight Survey, PC on August 4, 2022.
BENCHMARK
Datum for topography is NAVD 88
FLOODZONE
FEMA flood insurance rate map (community panel 51003CO295D), effective date February 04, 2005 shows this property within zone "x"
and no portion of the property within the 100-year flood plain.
RESERVOIR WATERSHED
This site is within the Middle Rivanna Watershed. This site is not within a watershed of a public water supply.
WATER & SANITARY SERVICES
This project does not lie within the Albemarle County Service Authority Jurisdictional area for water or sewer. Existing drainfields and
wells are located on site and serve the existing commercial uses.
EXISTING USE
6,000 SF Mixed Commercial and Light Industrial uses
PROPOSED USE
38,000 Warehouse Space (in addition to existing uses)
BUILDING HEIGHTS
Maximum Allowable Height: 65 FT
Maximum Proposed Height: 40 FT
FFE Lower Floor = 377.00, FFE Upper Floor = 387.00
LAND USE SCHEDULE
Existing
SF
AC
%
Proposed
SF
AC
%
Building
6,056
0.14
5.4%
Building
25,056
0.58
22.4%
Pavement
30,517
0.70
27.3%
Pavement
34,710
0.80
31.1%
Concrete
551
0.01
0.5%
Concrete
551
0.01
0.5%
Impervious
37,124
0.85
33.3%
Impervious
60,317
1.38
54.0%
Turf
25,000
0.57
22.4%
Turf
16,000
0.37
14.3%
Woods
49,488
1.14
44.3%
Woods
35,295
0.81
31.6%
Total
111,612
2.56
100.0%
Total
111,612
2.56
100.0%
Limits of Disturbance = 69,200 SF (1.59 acres)
PARKING SCHEDULE
REQUIRED PARKING:
Per Albemarle County Code of Ordinance Sec.4.12.6:
Wholesaling or Warehousing use not otherwise identified in Sec. 4.12.6 requires 1 space per employee
plus 1 space per 500 square feet floor area open to the public =
Existing Building: 20 employees + 500 SF open to public = 21 spaces required
New Building: 9 employees + 500 SF open to public = 10 spaces required
Total Parking Spaces Required = 21+10 = 31 parking spaces required
PARKING PROVIDED:
Existing Parking Area: 22 spaces (includes one HC space)
New Parking Spaces: 9 spaces
Total Parking Provided = 31 spaces
SIGNS
All signs and pavement shall conform with the latest edition of the MUTCD Guidelines.
A sign permit must be issued in accordance with the Albermale County Sign Regulations prior to placement of any signs on -site.
Contractor shall provide handicap signs as shown on plan.
LIGHTING
Lighting shall comply with Section 4.17 of the Albemarle County Zoning Ordinance. There shall be no light fixtures exceeding 3000
lumens. No High Intensity Discharge Lighting shall be used. Illumination at the ground emitted by townhouse wall -mounted fixtures or
any other fixture source shall not exceed 20 footcandles. No Lighting plan is required for this Site Plan.
ITE Trip Generation, IIth Edition
AM
PM
WEEKDAY
Use Description
ITE
city
IV
In
Out
Total
In
Out
Total
In
Out
Total
General Light Industrial
110
6.000
1,000 SF
5
0
5
1
4
5
15
14
29
Warehousing
150
38.0
1,000 SF
5
3
8
2
7
9
32
33
65
I np generation renects Hm ana rm peaK nour tramc.
RELEVANT APPLICATIONS
INITIAL SITE DEVELOPMENT PLAN
2305 HUNTERS WAY
PARCEL ID 07900-00-00-004PO
AND A PORTION OF PARCEL ID 07900-00-00-004AO
ALBEMARLE COUNTY, VIRGINIA
Initial Site Plan: current submittal Special Exception Request: Not Applicable Road Plan: Not Applicable
VSMP Plan: to be submitted with Final Site Plan Subdivision Plat: Not Applicable
GENERAL NOTES
1. The information and data shown or indicated with respect to the existing underground utilities at or contiguous to the site are based on
information and data furnished to the owner and engineer by the owners of such underground facilities or others. The owner or engineer shall
not be responsible for the accuracy or completeness of such information or data. The contractor shall have full responsibility for confirming
the accuracy of the data, for locating all underground utilities, for coordination of the work with owners of such underground utilities during
construction, for the safety and protection thereof and repairing any damage thereto resulting from the work. All of these conditions shall be
met at no additional cost to the owner. The contractor shall contact "Miss Utilities" of Virginia at 1-800-552-7001 prior to the start of work.
2. When working adjacent to existing structures, poles, etc., the contractor shall use whatever methods that are necessary to protect structures
from damage. Replacement of damaged structures shall be at the contractor's expense.
3. The contractor shall be responsible for protecting all existing site structures from damage and coordinating work so that the owner can make
necessary arrangements to modify/protect existing structures from damages.
4. The contractor shall be responsible for notifying all utility owners, adjacent land owners whose property may be impacted and the Virginia
Department of Transportation prior to completing any off -site work.
5. Contractor shall notify and coordinate all work involving existing utilities with utility owners, at least 72 hours prior to the start of construction.
6. Contractor shall immediately report any discrepancies between existing conditions and contract documents to the owner and engineer.
7. Contractor shall submit for the approval of the owner submittals of all specified materials listed in the plans, to include shop drawings,
manufacturer's specifications and laboratory reports. the owner's approval of submittals will be general and will not relieve the the contractor
from the responsibility of adherence to the contract and for any error that may exist.
8. All bare areas shall be scarified, limed, fertilized, seeded and mulched.
9. All trees, saplings, brush, etc. shall be removed from within the right of way and the drainage easements.
10. Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated.
11. Retaining walls require separate building permits.
12. All water service lines, sanitary laterals, and sprinkler lines must be visually inspected by the Albemarle County Building Department from the
main to the structure.
13. Accessible parking spaces, access isles, and accessible route shall be installed in accordance with [CC ANSI At 17.1-09 and the 2018
Virginia Construction Code
14. Where the flood level rims of plumbing fixtures are below the elevation of the manhole cover of the next upstream manhole in the public
sewer, the fixtures shall be protected by a backwater valve installed in the building drain, branch of the building drain or horizontal branch
serving such fixtures. Plumbing fixtures having flood level rims above the elevation of the manhole cover of the next upstream manhole in the
public sewer shall not discharge through a backwater valve.
15. All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks.
16. Buildings or structures built before January 1, 1985 must have an asbestos survey performed in order to apply for a demolition permit.
Asbestos removal permits are required if positive for such from Albemarle County and VDOLI. Contact VDOLI for their additional
requirements and permits for demolition projects at 540-562-3580 x131.
17. All water, sewer and fire lines require NEW inspection and testing procedures. The ACSA performs any testing and inspections of the public
sewer and water main(s).
18. The Albemarle County Building Inspections Department(ACBID) does a visual inspection and witnesses the testing of the building drain,
water service pipe and the sprinkler lead-in connection.
19. The developer/contractor is responsible to retain a Special Inspector as outlined in the updated Albemarle County Policy for Site Utilities to
perform the visual inspection and testing of all utilities not covered by the ACSA or ACBID. This includes building sewers, water and fire line
branches between the main and the meter(s)/building(s).
20.The Special Inspector's report must be submitted and approved by the Albemarle County Engineering Department prior to a Certificate of
Occupancy being issued.
VICINITY MAP SCALE:1"=1000'
Map provided by Google.com
SHEETINDEX
C1 COVER SHEET
C2 EXISTING SITE LAYOUT
C3 DEMOLITION PLAN
C4 SITE LAYOUT
C5 GRADING AND UTILITY PLAN
SHIMP
ENGINEERING
LAND PLANNING -PROJECT MANAGEMENT
912 E. HIGH ST. 4M.227.5140
CHARLOTTESVILLE VA 22902 JUSTIN@SHIMP-ENGINEERING.COM
O
v JU
o.!SHI0MP
45183
wAr
DESIGNED BY
J. Kelly Strickland
CHECKED BY
Justin Shimp, P.E.
INITIAL SITE DEVELOPMENT PLAN
2305 HUNTERS WAY
ALBEMARLE COUNTY, VIRGINIA
SUBMISSION:
2023.01.17
REVISION:
1) 20XX.XX.XX (DESCRIPTION)
FILE NO.
22.072
COVER SHEET
C 1
TMP 78—ARM /
HEARTROCK FARM LLC
DB 4611 PG 429
ZONED HIGHWAY COMMERCIAL /
O
7)
19
BOUNDARY CURVE TABLE
—urve
Length
Radius
Delta
Tangent
Chord
Chord Bearing
C1
62.83'
40.00'
89°59'50"
40.00'
56.57'
38°06'13" VV
C2
203.92'
280.00'
41'43'40"
106.72'
199.44'
13'57'48"
TMP 79-4N
PRIME STORAGE CHARLOTTESVILLE, LLC
INST.#202100003783
LIMITS OF THIS SITE PLAN (69,200 SF) ZONED LIGHT INDUSTRIAL ,
------ - -�- -� N55'10 24 E 384.52
TMP 79-4P
N/F WP RICHMOND ROAD, LLC
INST.# 202200000344
DB 688 PC 625 (PLAT)
ZONED HIGHWAY COMMERCIAL
i
u
0
TMP 79-4A
N/F WP RICHMOND ROAD, LLC
INST.#202200000344
DB 492 PC 76 (PLAT)
ZONED HIGHWAY COMMERCIAL
4.029 AC.
\ TMP 79-4D
N/F SOPHIL COMPANY
DB 1139 PG 498
\
ZONED LIGHT INDUSTRIAL
i
i
i
t�111
TMP 79-4D
/N/F SOPHIL COMPANY
DB 1139 PG 498
ZONED LIGHT INDUSTRIAL
00 /
j.
o ,� j
`^� .
Op/J
GJ
SHIMP
ENGINEERING
LAND PLANNING -PROJECT MANAGEMENT
912 E. HIGH ST. 404.227.5140
CHARLOTTESVILLE VA 22902 JUSTIN@SHIMP-ENGINEERING.COM
�jNL 1 H
o
v JUSTT>!SHIMP
I .45183
10 w�
SS)(IIATAT
DESIGNED BY
J. Kelly S6ickland
CHECKED BY
Justin Shimp, P.E.
INITIAL SITE DEVELOPMENT PLAN
2305 HUNTERS WAY
ALBEMARLE COUNTY, VIRGINIA
SUBMISSION:
2023.01.17
REVISION:
1) 20XXXXXX (DESCRIPTION)
y� N FILE NO.
22.072
EXISTING SITE
LAYOUT
C2
/ I TMP 79-4N
I — — — PRIME STORAGE CH ARLOTTESVILLE, LLC
INST.#202100003783
LIMITS OF THIS SITE PLAN (69,200 SF) ZONED LIGHT INDUSTRIAL
TLINK`TENCfD mL. ,.—,.—,.— L.—L.
— \ -_-11 A — -
/
/ --- -
11,702
w F CRIT
SLOPESSDISOTURBANCE / / ��.' // .i/� '// -16 vvvv A
I J
4 CONCRETE § e I I PROPOSED
CHANNEL I I I I I
7,775 SF OF ITS
s \
SLOPES DISTURBANC
----�_� ----
— vv �` ///'/,/ �� V A\ TMP 79-4D
/ - I -- i — — — _ /� / - /j / I V A NSF SOPHIL COMPANY
I DB 1139 PG 498
�NED LIGHT INDUSTRIAL
—7
CONCRETE
\\ / �� CONCRETE
LIMP BWALL
HEARROKFARM LLC �_
--DB 4611 PG 429 % _ _ZONED HIGHWAY COMMERCIALx
� ( 80- v \
V\\A V \
ASPHALT
°2 USED it
ETAL 9`
/ GAS ��� BOL ���RAMP (TBR) AV A r�// / �- ���, �e�� v\ 4��
G49V.CC x3 ( �' i v `� A A ` — i� / / / � �O . �� I I
NO NC
0\ 00 V A
STEPS °i� 6 \ V Av �� /l /i' L /°� SI V CONCRETE FOM
�� A
/ 1 �\ ® /� jbBOLX5 AV A YYELL / /�/: /aT° ,9I 'Al WALL /
CO ASPHALT
SLAB FF \ \�
/CO �/ ���' I �� �\ �A9
\ l \ �% �— // 3�'x v--� `"k // \\ FOM CHAINLINK I I
ASSPHALT / v v FENCE
c_
ASPHALT376.65
SLAB FF--"�, // �V / / — ��v CONCRETE\ v / % vv APPROXWALL
.
%��� V� �W/ i �xJ� /' �v vv // "\� // �/ vv v :- �/ A� v LOCATION EXISTING \ DRAINFIELD \ /
BOLD \ ,I `%0 \ \ GM
APPROX. v /
FOM x2 / \ LOCATION \
\ `u '`�� \ / � \ v EXISTINGv
Lam\ k } / I \DRAINFIELD
o� U9S ERA
\ UP y\ O G�q I I AJ\ SIN
FOM x2
\
�I
FOM SDMH/' ' \
\�v
\
RIP RAP
DRAINAGE
CHANNEL \
x
c,y 2
� \ I
F
9M
OVAVA4-
v
\ \
�\
\\ \ \ \ N
\
co
\
GOL
376.99 \ \ \ / FOM S
0—�SLAB FF
'.A V % CRITICI4 /SLOPES HATCH
(AS SHOWN ON
All �q/vV "AVLBEMARLE COUNTY GIS)
t �
/
/
r /
/
TMP 79-41D
/ /F SOPHIL COMPANY
_ IDS 1139 PG 498
ZONED LIGHT INDUSTRIAL
/
1 \ \\ FOM FOM Guy
GyN ,
ASPHALT
\ \ \ GRAVEL
\ I / PATH/ROAD
\\ ` Guy
C0 / /
\ oP UPale J /
zWE
ole
\ \\ \ /
I�.L GAS —GA
GS—GAS—GAS—.\A GAS GAS WS GAS
vT'
1 /
WELL
\ I
\\ /
\Guy
CRITICAL SLOPES DISTURBANCE NOTE
THESE CRITICAL SLOPES SHOWN WERE CREATED
WITH CONSTRUCTION OF PREVIOUSLY APPROVED
SITE PLANS. SEE SDP199800013 FOR REFERENCE
912 E. HIGH ST. 404.22T.5140
CHARLOTTESVILLE VA 22902 JUSTIN@SHIMP-ENGINEERING.COM
��'AI.TII
o
v JUSTTI!SHIMP
I o. 45183
�o w�
frIATAT
DESIGNED BY
J. Kelly S6ickland
CHECKED BY
Justin Shimp, P.E.
INITIAL SITE DEVELOPMENT PLAN
2305 HUNTERS WAY
ALBEMARLE COUNTY, VIRGINIA
SUBMISSION:
2023.01.17
REVISION:
1) 20XXXXXX (DESCRIPTION)
FILE NO.
DEMOLITION
o PLAN
22.072
C3
I
TMP 78-49A
HEARTROCK FARM LLC
DB 4611 PG 429
ZONED HIGHWAY COMMERCIAL
/
/
/
X
X
O
ti —x _X _X
R 140.00'
LARGE
SHADE
TREE
LARGE
SHADE
TREE
LARGE
TMP 79-4N
PRIME STORAGE CHARLOTTESVILLE, LLC
INST.#202100003783
ZONED LIGHT INDUSTRIAL
1000' �- BLOCK RETAINING WALL
R18.00'
CG-2
\i
R150.00'
UGU
U
°J 38,000 SF WAREHOUSE SPACE
(1q n00 4F PFR FI nnR)
- GAS \
GAS
i
�o
TIE INTO EXISTING
45' TRAVELWAY
UGU \ UGU' UGU
\ / \
GJ
J /
OJ/
J
\ r
GJ
J
® /
SDMH
c
oc/
/c
UP
v \�
�Q
f
p�J LARGE
SHADE TREE
J,6,n ✓i
SEVEN (7) NEW
SPACES 0 9'x18'
LARGE SHADE
TREE
LARGE SHADE
TREE
\ TWO (2) NEW
\+ SPACES
R6.00'
BLOCK
RETAINING
WALL
2.00'
2.00'
0y
G
912 E. HIGH ST. 404.227.5140
CHARLOTTESVILLE VA 22902 JUSTIN@SHIMP-ENGINEERING.COM
�jALTH
o J��
viTis. !SHIMP
I o. 45183
w�
��SSynTi AT E���
DESIGNED BY
J. Kelly Sbickland
CHECKED BY
Justin Shimp, P.E.
INITIAL SITE DEVELOPMENT PLAN
2305 HUNTERS WAY
ALBEMARLE COUNTY, VIRGINIA
SUBMISSION:
2023.01.17
REVISION:
1) 20XX.XX.XX (DESCRIPTION)
FILE NO.
SITE LAYOUT
22.072
Scale: 1"=20'
C4
I
TMP 79-4N 12' DR/
PRIME STORAGE CHARLOTTESVILLE, LLC DB
INST.#202100
003783
\\ ` ZONED LIGHT INDUSTRIAL DB
�(� �I/ \\�I --- CHAIIINLINK FENCE
\ -390 I Y I I ` `\ �� — \ 94-- — --\ __ '� MA�ET. WALLS -� -- ^\----- —X —X g T \ �`
HT. b6FT 96 / J / / 9490
�
....:::...
96 - ' 8 8-7 / 88 96,
82 94 8750
`b 11 90 / / -- — / / �, /- // /� el P
— V vv --—j= — --- —___ \\ X
/
85'
or t�17
/ v _v <� F
/ TP 3tenti
— — — — — ---� / �—/�/ \ CONCRETE
TMP 78-49A I / / _ _ — — — — — — — — — 1O--��y / / / /� WALL
HE
DR 4611KPGR429LC �— _--- ---- — — — — - \\ - \� /7
ZONED HIGHWAY COMMERCIAL / l / — — = _ — — _ _ _ — — — — — — — — — — — — — -\ \ \ \ \ _ 00,
ASPHALT
38,000 SF �AREHOUSE SPACEV
(19,000 SF PER FLOOR)
�--GAS �� A 9 NEW PARKINS SPACES \ V / / f
V A / CON'C*ID
U P
00
i STEPS °�o A / % / 1 tiO� CONCRETE
\ \ °tip WALL
CO �o
SHIMPFOM / v CSC
/ J/ / \\yG \ `\ ENGINEERING2.
DO//CC ,�9 \ LAND PLANNING - PROJECT MANAGEMENT
1 /
FOM/ �'l" Q \ ` \ v o \ O/yG / \ - a 912 E. HIGH ST. 4M.22].5140
V q"PHALT O CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEENING.COM
SDG
i
L x� 1 \ B / � �° 2 'DRAIN GE EASI DENT °N /
V v V A A underground — / ° DB 88 PG 625
\ " \ \
/ ormwater �—�" / / �° — vv �. UP °tio �
\ \ \ \ ASPHALT \ D ention / / \ 0 \
I �° v EALTH376,65
SLAB FF- � / i °°� CONCRETE
0 v tib o �1
\ } / /
WALL / \ \ U JUSTT !SHINM a
°�� /_ /—x �� / \ / / e /° \ rT
/ X Q� V A - o.45 183
QJ BOL \ o9O
\O w�
,1 O A
SGAN /� V A s° S V \° ��70NAL E�
c 5 FOM x2 \ A- \ APPR \ / / / BOIL — \ \ yG
9s � \ / / / � E \ LOCATION EXXISTING
DRAINEIELD \ / z°/
UP oBOL
\ n TERS/ \ \ `� `> / /� o
/ I I 376A9 `\ DESIGNED BY
Gyp AJL S16 I , ,
0 \ V `
J. Kelly Strickland
FCM x2
XUGU
2
TE VA
Oy DRP RAAI AGE
P \ \ I \
0 FFOM \\ 0\0 \ \\ \\\\� \ \\ j// /;-- / CHAN L O /
SDM
v�\�yv\ vv //
Stormwater Note:
Underground detention, as shown on this plan, will
/ / �p / be used to manage stormwater volume. Nutrient
v V A y/ / // / / / / y / �I / // // credits will be purchased to manage water quality.
RIP Water and Sewer Note:
RAP
DRAINAGE � � , A new well location, as shown on this plan, will
CHANNEL \ \�, v �� \Ole/ �� �� _ �/ / /� / / \\ I / / replace the well proposed for removal. The new
, // building is proposed to share the existing drainfield a 4,
ti
\ v �V Avg v = X— / \ / I /� on Parcel 4P. p�
CHECKED BY
Justin Shimp, P.E.
INITIAL SITE DEVELOPMENT PLAN
2305 HUNTERS WAY
ALBEMARLE COUNTY, VIRGINIA
SUBMISSION:
2023.01.17
REVISION:
1) 20XXXXXX (DESCRIPTION)
FILE NO.
22.072
S��9s\ M' \` �\ / / \\\ ' I i / GRADING AND
0 20 An YD / UTILITIES
Scale: 1"=20' /
C5