HomeMy WebLinkAboutSDP202200048 Correspondence 2023-03-27 (2)SHIMP ENGINEERING, P.C. Design Focused Engineering March 23, 2023 Cameron Langille County of Albemarle Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 RE: Response Letter #2 for SDP2022-00048 Regents School Major Site Plan Amendment Dear Cameron, Thank you for your review of the site plan amendment for Regents School of Charlottesville. This letter contains responses to County comments dated February 16, 2023.Our responses are as follows: 1. [32.5.2 (c)] Please provide a phasing plan. No Certificates of Occupancy can be issued for any of the buildings until all other site improvements are installed, unless a phasing plan is provided for this project. Jalen Boone, jboone@albemarle.org, is the site inspector for this project and is willing to assist the applicant with developing a phasing plan that will allow CO's to be issued for individual buildings. Be aware that all features shown within specific phases will be required to be installed prior to issuance of CO's for buildings within each individual phase. Rev. 1: Per applicant comment response letter, a phasing plan will be provided prior to final site plan approval. The phasing plan should be included as a sheet on a future resubmittal for staff to review. RESPONSE: Thank you for your comment. We have provided a phasing plan on Sheet C5 for review. 2. [32.5.2 (n)] Please identify what the rectangular structure between buildings A and B is. Rev. 1: Per applicant comment response letter, please add a callout identifying the pavilion and include the statement that it will not be enclosed, per applicant comment response letter. Please show dimensions on all four sides of the pavilion. RESPONSE: A call -out and dimensions have been added for the pavilion. 3. [32.5.2(n)] Provide the location and dimensions for all existing and proposed improvements including: buildings (max height for each building), walkways, fences, walls (including height), trash containers, outdoor lighting, recreational areas and facilities, loading and service areas, and the proposed paving material types for all walks and parking lots. Rev. 1: Comment not fully addressed. Please provide dimensions along the exterior boundaries of all walkways and other hardscaped surface areas outside of the buildings. Currently, these dimensions are not labeled. RESPONSE: Walkway dimensions and building separation dimensions have been added to the plan. a. Exterior dimensions for all proposed buildings are not labeled, please provide this information on all applicable sheets. Rev. 1: Comment addressed. 912 E. High St. Charlottesville, VA 22902 1434.227.5140 1 shimp-engineering.com 4. [32.7.4.1] Approval of a VSMP Plan is required prior to final site plan approval. See attached Engineering review comments for further information. Rev. 1: Comment stands, please see Engineering Division comments. RESPONSE: Comment received. [32.7.8] Provide a lighting plan that addresses the following: a. [4.17] Show the location of all outdoor lighting for any luminaries equipped with a lamp which emits 3,000 or more maximum lumens. Rev. 1: Comment partially addressed. The lighting plans do not show any outdoor lighting around the building and walkway areas. Is any outdoor lighting proposed, including wall mounted liehts? If so, please revise the liehtine plans to identify these liehts and their locations, and update the photometric measurements as necessary throughout the site. RESPONSE: Building light fixtures are not proposed. b. [4.17] Provide a luminaire schedule identifying each type of outdoor luminaire proposed. Include the manufacturer name, model number, lamp type (e.g. LED, incandescent, etc.), wattage/lumens emitted, and pole/mounting height. Include a column in the schedule that identifies the symbology used for each fixture on the lighting plan. State the number of each outdoor luminaire provided by type. Rev. 1: Comment may be addressed pendine applicant comment response to comment #14a above. RESPONSE: Building light fixtures are not proposed. c. [4.17] Revise the photometric data table so a Light Loss Factor (LLF) of 1.0 is used to calculate footcandle measurements. Revise the footcandle measurements shown on the plan as necessary. Rev. 1: Comment may be addressed pendine applicant comment response to comment #14a above. RESPONSE: Building light fixtures are not proposed. d. [4.17] Show footcandle measurements for the entirety of the site. Please be aware that spillover from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed onehalf foot candle. It appears that the lighting max exceed this requirement in certain places. Rev. 1: Comment stands. Footcandle measurements alone the public ROW north of the athletic field ereatly exceed 0.5 footcandles alone the property boundary on Sheet C18. The liehtine locations must be revised so that footcandle measurements do not exceed 0.5 footcandles. Additionally, is there a reason why the liehtine plan is broken into three separate photometric drawings? Currently, parking lot lighting is shown on Sheet C17, and Sheet C18 has two other photometric plans (one for the athletic field lighting and one for RESPONSE: Thank you for coordinating with us over email regarding this comment. Per email correspondence, this comment is addressed as the athletic field lighting plans show that athletic field lighting will not exceed 0.5 fc at the property line. Staff was also informed that there are two lighting plans as separate lighting companies were used for the parking lot lighting and the athletic field. 6. Prior to site plan approval, easement plat for all proposed easements must be approved and recorded. Once the easement plat is recorded, update all new easement labels to state the easement type, dimensions, and recorded instrument (deed book and page number). Rev. 1: Comment acknowledeed by applicant. Easement plat application submission is forthcomine. Once the easement plat is recorded, update all new easement labels to state the easement type, dimensions, and recorded instrument (deed book and page number). 912 E. High St. Charlottesville, VA 22902 1434.227.5140 1 shimp-engineering.com RESPONSE: Comment received. If you have any questions or concerns about these revisions, please feel free to contact me at Rachel@shimp-en ing eering com or by phone at 434-227-5140. Regards, Rachel Moon 912 E. High St. Charlottesville, VA 22902 1434.227.5140 1 shimp-engineering.com