HomeMy WebLinkAboutSDP202300020 Review Comments Final Site Plan and Comps. 2023-03-28�q off nig 401 McIntire Road, North Wing Charlottesville, VA 22902-4579 County of Albemarle Telephone:434-296-5832 COMMUNITY DEVELOPMENT DEPARTMENT WWW.ALBEMARLE.ORG ��BGIN�Q' Site Plan Review Project title: Forest Lakes Self -Storage — FSP Project file number: SDP2023-00020 Plan preparer: Shimp Engineering, 912 E. High St., Charlottesville, VA 22902 Justin Shimp, PE, justin@shimp-en ing eering com Applicant: JA-ZAN Limited Partnership 250GTOgpepsieva.com P.O. Box 9035, Charlottesville, VA 22911 Owner or rep.: Centennial American Properties 935 S. Main St., Suite 201, Greenville, SC 29601 llasontn,CaDl10.COm j Plan received date: 27 Mar 2023 Date of comments: 28 Mar 2023 Reviewer: John Anderson, PE Review Coordinator: Mariah Gleason Engineering has reviewed the final site plan and offers the following review comments: 1. General: a. WPO202200050 plan approval is required prior to FSP approval. Last engineering review comments (minor items) sent 3/14/23. b. SWM facility easement and public drainage easement (deed /plat — SLM202300011) must be approved, via separate application review /approval process, and recorded prior to WPO plan approval. Once all plat review comments are addressed, Engineering will format the deed. 2. C3: Revise 4.5' sidewalk to 5' Min. It appears possible to reduce 30.0' drive aisles to 29.50' to provide additional sidewalk width— 5.0' Min. sidewalk width is ordinance (18-32.7.2.3), VDOT, and ACDSM standard (Sec. 7, p. 20). This dimension (5.0' Min.) is critical since 4.5' sections touch building face /no escape in that direction. To simplify: C3 labels may indicate change without linework revision, but labels must require 5.0' sidewalks (Min. width) and would seem to limit access aisle width to 29.5'. Drive aisles and sidewalks must be built to ensure 5.0' Min. required sidewalk width. 3. C 10: Please revise road section detail to reflect 5' sidewalk, rather than 4.5' sidewalk; i.e., lane width 14.75', 12.75'. This will also support no linework revision, and clarify drive aisle /lane dimension. 4. Cl: a. Provide date of boundary and topographic survey provided by Meridian Planning Group LLC. b. Provide cover sheet stormwater management narrative. c. Recommend list associated plan, WPO202200050. 5. C4: Revise grading to show no off -site grading on parcel to the north, consistent with WPO202200050, C4. Engineering Review Comments Page 2 of 2 C4, WPO202200050: Thank you. Please call if any questions — tel. 434.296-5832-x3069, or email ianderson2galbemarle.org. SDP202300020_Forest Lakes Self -Storage _FSP_032823