Loading...
HomeMy WebLinkAboutSP202200020 Public Notification 2023-03-21. JSLIC NOTICE SIGN # Application Number: I SP202200020 Posting Deadline 4212112022 &� I Staff Sign Posted 0 VIA84ProjectName Sign Removed Planning Commission Hearing 01/t0/2Q23 g� Board Hearing A BZA Hearing g 1 i+ Contact Sign status: Reserved As indicated on map. Owner Scott Clark Esmont- Scottsville Transmission Line Rebuild Project 4dditionai information DATE Contact: Scott Clark 434 project: 91,8E-832 ext.,83 64,8 or ,99selark@albemarle.org REMOVE 8 signs refer to this project: «51,82,83,84,87,88,89 & 94 PROJECT. SP20220002D Esmont- Scottsville Trans mission Line Rebuild Project L/AI C A MAGISTERIAL DISTRICT(S): Samuel Miller, Scottsville TAX MAP/PARCEL(S)t 11100-00-00-074A0, 128DO-DO-00-01300, 12800-00-00-013A0, 12800-00-00-05600, 12800-00-00-05700, 12800-00-OD-05900, 12800_00-00-08800, 12800-00-00-088A0, 12800-DO-00-09000, 12800-00-00-09100, 12800-00-00-09400, 12800-00-00-12400, 128A2-00-00-00800, 128A2-00-64-00900, 12SA2-00-00-013D0, 128A2-00-00-01400, 128A2-OD-00-01500, 128A2-00-00-01SA0, 128,42-00-00-01800,12842-00-00-01960,128A2-00-00-02100,128A2-00-00-02200,12aA2-00-00-02300, 128.412-00-00-02400, 128A2-00-OM2500, 128A2-00-00-02560, 12860-00100-01600, 12860-00-00-01700, 12900-60-00-00600, 12900-00-00-00700, 12900-00-00-D07A0, 12900-011-00-007CO3 12900-06-00-0071)0, 13000-00-0.0-007N0, 13600-00-00-007NN, 13000-00-0-007P0, 13000-00-00-00700, 130DO-OD-06-007R6, 13000-00-00-007TO, 13000-00-00-00800, 13000-00.00-011AD, 13000-00-00-01500, 13000-00-00-04600, 1300MO-00-040AO, 13000-00-00-04000, 13000-00-00-04100, 13000-013-00-041CO, 13000-00-00-041C1 LOCATION: Fromthe northwest side of the intersection of Route 6 (Irish Rd) and Route 715 (Esmont Rd), running eastward on the south side of Route 6 to the Scottsville Substation on Route 726 (James River Rd), a corridor of approximately six miles. PROPOSAL: Replace existing power -line support pales with an average height of approximately 40 feet with new poles with an average height of approximately 60 feet in order to install a new 46-HaVolt poweriine, on an existing transmission line route of approximately 6 miles. along an existing utility easement. PETITION: Energy and communications transmission facilities under Section 26.2(a) and Section 10.2.2(6) of the Zoning Ordinance, crossing 47 parcels of land totaling approximately 2,277 acres. No dwelling units proposed. ENTRANCE CORRIDOR: Yes OVERLAY DISTRICT(S): Steep Slopes Overlay district, Flood Hazard Overlay district COMPREHENSIVE PLAN: RuralArea - preserve and protect agricultural, forestal, open space, and natural, historic and scenic resources; residential (0.5 unit/ acre in development lots).