HomeMy WebLinkAboutWPO201700023 Review Comments As-Built Reviews 2023-03-31John Anderson
From: John Anderson
Sent: Friday, March 31, 2023 3A8 PM
To: Steve Edwards
Cc: Jonney Otto; Dan Ratzlaff, Emily Cox
Subject: Planning Application Review for WPO201700023 Oakleigh. [ As-bult review ]
The Review for the following application has been completed:
Application Number= WPO201700023, As -built drawing review
Reviewer = John Anderson
Review Status = Requested Changes
Completed Date = 03/31/2023
This email was sent from County View Production.
Hi, Steve,
Thanks for your patience.
Please accept As -built drawingreview eview comments (also in CV):
`update, janderson2 3/31/2023 3:46 PM:
1. Provide stormwater routings for underground detention system to ensure compliance with SWM quantity requirements
since two weir plate orifices (6" x 6" ; 25"(w) x 4"(h)) and concrete baffle wall (weir wall) are all constructed lower than
design, by 0.92', 0.75', and 1.40' respectively. Ref. sheet 1 Const. Record Drawings (As -built) for VSMP, item C.8
(significant deviations), and submit computations.
Note: With As -built baffle wall ht.=546.80', it appears the system does not detain /contain the 10-yr event, as designed,
since 10-yr WSL=548.15'. Baffle wall (weir wall top) design elev.=548.20'. If UG system does not meet design SWM
performance standards or requirements, please propose remedy.
2. Please provide labels at plan view of UG detention to indicate that surface paving is incomplete, and that at present not
all storm runoff designed to reach the unit (for detention /water quality treatment) is reaching the unit.
3. Provide SWM Narrative that discusses partial detention (item 2) and lack of water quality treatment at UG detention,
since sheet 13 Stormfilter Standard Detail labels indicate stormfilter cartridges have not been installed as of
survey. Although labels are accurate reflection of As -built condition, narrative is required to substantiate effect of partial
installation of approved SWM system.
4. Sheet 3: Provide deed bk.-pg. reference to recorded SWM and public (proposed) drainage easements. Ref. sheet 1
Const. Record Drawings (As -built) for VSMP, item C.10. Deed bk-pg ref. is sufficient, but this ref. should appear on the
As -built drawing. for example: SWM deed of easement: DB-PG 5230/688.
Note: Applicant furnished .PDF copies of recorded easements via download a -link, 2/24/23.
Note: Applicant is encouraged to submit As -built of ACSA utilities --
5. Sheet 13: UG Detention SWM A - outlet structure A4 detail (prior to WPO plan bond release): BTM=542.65' while
15" HDPE pipe INV IN =543.05'. Provide remedy to eliminate 0.4' pooled water in floor of structure (for example: place
0.4' depth flowable grout in floor of structure).
6. Capture and report WPO2017-00023 Amendment #1 (approved 3/26/18), sheet 11, SWM Plan -post-development
drainage area map impervious and permeable pavement areas that route to either SWM facility (biofilter, or UG
Detention). Compare as -built areas with Amendment #1 design, and furnish SWM narrative calcs. as needed, to provide
compliance demonstration, or context.
7. Compare As -built SWM facility phosphorus removal with WPO201700023 Amendment #1, sheet 12, SWM Plan -
SWM Quality/BMP map label, which reads: 'BMP #1 and #2 provide 3.78 lbs/yr phosphorus removal > 3.27 Ibs/yr
required.'
8. List biofilter area provided; same ref: Sheet 12, Amendment #1.
9. Provide bioretention basin section detail (details: elevs., matrix, stone depth, fabric, R-tank dimensions, etc.): Ref.
WPO201700023, Amendment #2, approved 6/5/19, sheet 14, SWM Plan - SWM B details.
10. Provide permeable paver and pavement as -built details (paver type, bedding depth, slope, underdrain, etc.): Ref.
WP0201700023, Amendment #2, approved 6/5/19, sheet 15, SWM Plan - SWM B details.'
As -built drawing, sheet 13
REINFORCED CONCRE I
BAFFLE WALL SECURED
TO STRUCT�IRE WALLS
TW= �
60' CMP PIPE
(PERFORATED)
Additional
Additional
MANHOLE RISER ACCESS
RIM ELEV. 551.05
VDOT STD.
STA STEPS
I i 25"(W) x 4"(H) ORIFICE
W/TRASH RACK
— — INV. 545.60
2-YR ELEV. 546.55i,11_ _ 6" z 6" ORIFICE
_ — W/ TRASH RACK
INV. 543.70
V ELEV. 544.62_a_ _
2,520 CUBIC FT F543.05
INV. 5432p INV.
BT—M= ^ �y 15" HDPE PIPE r
6" PVC PIPI
J J TO STORM FII
6" PVC SECTION
It 543.20
OUTLET STRUCTURE A4
WPO201700023, Amendment #1, sheet 11
POST DEVELOPMENT RUNOFF AT POINT OF
= 5.37 Acres (modeled as 3 sub areas in Hydrocad)
(Includes 1.49 Acres of Permeable Paver)
Dev. Area w/o SWIM = 0.65 Acres (6S) - Shown as hatch
CN = see SW Model Printout
Q21P-0 = 1.76 cfs < Q2(Pro) = 2.28 cfs (no change)
Q,oiP�> = 7.77 cfs < Q101Pre� = 8.84 cfs (no change)
Sub Watershed to Bio-Retention
D.A. = 4.72 Acres (-.04 SWM FACILIT
EASEMENT AROUND
Impervious rea= .8 cres PAVER PAI
Permeable Paver Area = 1.49 Acres
Dev. Open/Landscape Area = 1.16 Acres (-.04)
oods! rass Combo rea = 0.2 cres
Tc = 5.00 mins.
1,Z) Sub Watershed to 60" HDPE
_..-.. ! D.A. = 3.19 Acres (+.04 + .34)
Impervious Area = 1.39 Acres (+.01 + 0.30)
Permeable Paver Area = 0.84 Acres (+.07)
ev. pen Lan scape Area = 0. Acres 4 +. 41)
Woods/Grass Combo Area = 0.25 Acre
Tc = 5.00 mins.
POST DEVELOPMENT RUNOFF AT POINT OF
AKIAI void rno AMMA A
D.A. = 3.93 Acres (modeled as 4 sub areas in Hydrocad) (+.04 + 0.34)
Dev. Area to 60" HDPE = 3.19 Acres (2S) & (3S*) & (14S) (+.04 + 0.30)
*Includes 0.84 Acres of Permeable Paver Area (+.071
CN = see SW Model Printout
= 0 i
Q2(Post) = 2.55 cfs < Q2(pm) = 2.57 cfs
Q10(posp = 8.76 cfs < a10(w) = 8.90 cfs
WP0201700023, Amendment 41, sheet 12
BMP #1
BIO-RETENTION
D.A. = 4.72 Acres (-.04)
79,511 sf of Impervious Area (+34 sf)
r11 x 2.5" = 1,988 sf Biofilter Area Req. (+1 sf)
RinflIter Area Provided = 217fi sf
ovoia]----I
3
BMP#2
STORMFILTER
8'x6' Vault StormFilter w/ 50% RR
E§CULW_T97-Mffea1es1
60,480 sf (1.39 ac.) of Impervious Area (+13,535 sf)
60,480 sf x 1/2 in. rain = 2,520 cf WQV (+564 cf)
2,520 cf of Detention routed through Stormfilter @ 0.25 cfs = 10 Cartridges (OK)
(BMP #1 D.A. includes 36,613 sf of permeable pavers) (+3,072 sf)
BM #1 & #2 provide 3.78 Ibs/yr Phosphorous Removal > 3.27 Ibs/yr required
WP0201700023, Amendment 42, sheet 14
SO MM SOLIDER PERIMETER
BANDING COURSE
NO.8 AGGREGATE
IN OPENINGS
EAGLE BAY AQUA BRICH
CONCRETE PAVERS
3 k MIN. THICK
2- NO.8 AGGREGATE
4- NO. 57 STONE
12- NO.3 STONE
COMPACTED \
SUBGRADE \ `
ASPHALTICONCRETE
PAVING SECTION
'I "I
FLUSH CURBIEDGE
RESTRAINT
VDOT2IA
GRAVEL BASE
FILTERFABRIC
OT21A DE R-35
GRAVEL
L 8' PERFORATED SDR-35
RAIN
SECTION ABUTTING PAVING GRAVEL STOUNDRM
R DRAINS)
BASE (TIE TO STORM DRAINS)
PERMEABLE INTERLOCKING PAVERS
SECTION
ASPHALTICONCRETE
1 & PAM-9.5 POROUS
PAVING SECTION
ASPHALTSURFACE
2)V PAM-19 POROUS
ASPHALT BASE
'I I
CLASS A3 CONCRETE
1` NO.8 AGGREGATE
FLUSH CURBIEDGE
COMPACTED
RESTRAINT
4- NO.67 STONE
COMPACTED
8' NO. 3 STONE
COMPACTED
COMPACTED —
SUBGRADE
VDOT2IA
GRAVEL BASE
FILTER FABRIC
OE r'a,
VOOT T21A 2IA 8'PERFORATED SOft-95
SECTION ABUTTING PAVING GRAVEL UNDERDRAIN
BASE mETOSTORM DRAINS)
PERMEABLE ASPHALT - ALTERNATIVE TO PCIP
SECTION
Thanks, again
best, J. Anderson
John E. Anderson, PE I Civil Engineer 11
Department of Community Development I County of Albemarle, Virginia
401 McIntire Road I Charlottesville, VA 22902
434.296.5832 ext. 3069
VDOT STD CG-6
NO.8 AGGREGATE
IN OPENINGS
— EAGLE BAY AQUA I
CONCRETE PAVER
31` MIN. THICK
2- NO.8 AGGRE
4` NO.57 STONE
12- NO. 3 STONE
� COMPACTED
SECTION ABUTT
Ir111OE1W.1n01W1�
t
1 TJ TJ
I
J J J
I � COMPACTED SUBGRADE
SECTION ABUTTING CU
6