Loading...
HomeMy WebLinkAboutCLE202300052 Other 2023-04-06 (2)ARCHITECTURAL # SHEET TITLE 00VER SHEET 1.0 LIFE SAFETY PLAN .5 I1.0 GENERAL NOTES/SCHEDULES .6 WALLTYPES FLOOR PLAN 0 ROOF PLAN & NOTES .1 ROOF DETAILS .0 EXTERIOR ELEVATIONS .1 EXTERIOR ELEVATIONS & DTL .1 STOREFRONT DETAILS .0 BUILDING SECTIONS .1 PARTIAL BUILDING SECTIONS 2 PARTIAL BUILDING SECTIONS 1 FIXED LADDER DETAILS .2 EXTERIOR DETAILS .0 FINISH FLOOR PLAN .1 RETAIL INTERIOR ELEVATIONS 10.0 INTERIOR ELEVATIONS 10.1 112 INTERIOR ELEVATIONS 11.0 INTERIOR DETAILS 11.1 INTERIOR DETAILS 11.2 INTERIOR DETAILS .0 TRASH COMPOUND EQUIPMENT PLAN & SCHEDULE TYPICAL EQUIPMENT DETAILS TYPICAL EQUIPMENT DETAILS GRAPHICS PLAN AND ELEVATIONS STRUCTURAL # SHEET TITLE .0 GENERALNOTES .0 FOUNDATION PLAN .0 ROOF FRAMING PLAN .0 FRAMING ELEVATIONS A FRAMING ELEVATIONS S7.0 FRAMING DETAILS S7.1 FRAMING DETAILS S7.2 FRAMING DETAILS S7.3 FRAMING DETAILS S7.4 FRAMING DETAILS S8.0 3D VIEW S9.0 STRUCTURAL TRASH COMPOUND MECHANICAL # SHEET TITLE M1.0 HVAC FLOOR PLAN M2.0 HVAC ROOF PLAN & DETAILS M3.0 MECHANICAL SCHEDULES & NOTES PROJECT INFORMATION PROJECT CONSISTS OF A CONVENIENCE RETAIL STORE WITH GASOLINE STEEL CANOPY - OPEN 24 HOURS. IICTION ALBERMARLE COUNTY COMMUNITY DEVELOPMENT DEPARTMENT 401 MCINTIRE RD., NORTH WING CHARLOTTESVILLE, VA22902 PHONE 434-296-5832 CODE INFORMATION BUILDING VERSION 2018 VA CONSTRUCTION CODE USE GROUP 'M' MERCANTILE PLUMBING 2018 VA PLUMBING CODECONSTRUCTION TYPE V - B, NOT MECHANICAL 2018 VA MECHANICAL CODE SPRINKLERED ELECTRICAL 2017 NAT. ELEC. CODE GROSS BUILDINGAREA 6,049.SF GAS 2018 VA FUEL GAS CODE OCCUPANTLOAD 78 ENERGY 2018 VA ENERGY CONSERVATION CODE FIRE PREVENTION 2018 VA STATEWIDE FIRE PREVENTION CODE ACCESSIBILITY 2018 VA CONSTRUCTION CODE, CH. 11/ANSI At 17.1-2009 LOCAL REGULATIONS 2018 VIRGINIA CONSTRUCTION CODE, CHAPTER 11 REQUIRED PROVIDED EXT. BRG. WALLS 0 HR 0 HR EXT. NON-BRG. WALLS 0 HR 0 HR INT. BRG. WALLS 0 HR 0 HR INT. NON-BRG. WALLS 0 HR 0 HR MISC. STORAGE 0 HR 0 HR COLUMNS 0 HR 0 HR STORAGE (EXTERIOR) 0 HR 0 HR TRASH STAGING 0 HR 0 HR SAFETY SYSTEM ALL SAFETY SYSTEMS SHALL COMPLY WITH NFPA LATEST EDITION EMERGENCY LIGHTING: PROVIDED ILLUMINATED EXIT SIGNAGE : PROVIDED AUTOMATIC FIRE ALARM SYS : PROVIDED MANUAL FIRE ALARM SYS : PROVIDED SMOKE DETECTION SYS : PROVIDED FIRE EXTINGUISHERS WILL BE PROVIDED BY WAWA IN ACCORDANCE WITH NFPA-10. FINAL FIRE EXTINGUISHER TYPE AND LOCATIONS TO BE APPROVED BY THE FIRE OFFICIAL PRIOR TO OCCUPANCY. THE PROPOSED LOCATIONS ARE SHOWN ON SHEET LS & A1.0. PLUMBING # SHEETTITLE P1.0 PLUMBING SANITARY PLAN P1.1 SLAB PENETRATION DIMENSION PLAN P2.0 PLUMBING DOMESTIC WATER PLAN P3.0 PLUMBING ROOF PLAN & GAS RISER ELECTRICAL # SHEET TITLE E1.0 ELECTRICAL POWER PLAN E2.0 ELECTRICAL LIGHTING PLAN E3.0 ELECT. ROOF POWER & LIGHTING PLAN E4.0 ELECTRICAL CONDUIT PLAN E5.0 ELECTRICAL PANEL SCHEDULES E6.0 ELECTRICAL ROOM PLAN & ELEVATIONS E7.0 ELECTRICAL ELEVATIONS E8.0 ELECTRICAL SINGLE LINE DIAGRAM E9.0 ELECTRICAL FIRE ALARM DEVICE PLAN E10.0 ELECTRICAL SECURITY SYSTEM PLAN E11.0 ELECTRICAL LOW VOLTAGE CABLE PLAN SYMBOLS LEGEND 1 DETAIL 16 A101)SIM REFERENCE O 1 IM BUILDING SECTION A101 V1 S AAXX.XX ;%Im WALL SECTION 1 Ref A101 INTERIOR ELEVATION ,Ref Ref 1 A101 1 D 10� EXTERIOR ELEVATION 1 Ref Room name ROOM TAG ACRC BLOCKING TAG KEYNOTE DOOR NUMBER EQUIPMENT TAG INTERIOR FINISH TAG Name DATUM Elevation ELEVATION O 1 View Name DETAIL A101 SCALE: 1/8" = 1'-0" DESCRIPTION GRID HEAD GAS CANOPY # SHEET TITLE CA1.0 ARCH- CANOPY PLAN, ELEVATIONS, AND DETAILS CA2.0 ARCH- CANOPY ROOF PLAN, ELEVATIONS, AND DETAILS CE1.0 ELECTRICAL CANOPY PLANS, DETAILS, SCHEDULES CS1.0 DESIGN CRITERIA AND NOTES CS2.0 FOUNDATION PLAN CS3.0 FRAMING PLAN CS4.0 SECTIONS CS5.0 DETAILS CS6.0 DETAILS MATERIALS LEGEND CONCRETE MASONRY UNIT (CMU) FA BRICK STONE CONCRETE ROUGH WOOD FINISHED WOOD CPVC TRIM OEM IITi lli ili EARTH •" "• TAG NUNN CONCRETE MASONRY UNIT (CMU) (ELEVATION) BRICK (ELEVATION) STONE (ELEVATION) EIFS (ELEVATION) STUCCO (ELEVATION) SIDING (ELEVATION) GLASS (ELEVATION) CERAMIC TILE - RESTROOM (ELEVATION) CERAMIC TILE - FOOD SERVICE (ELEVATION) ACROVYN (ELEVATION) FIBER REINFORCED PLASTIC (FRP) (ELEVATION) RT 29 & GREENBRIER DR CHARLOTTESVILLE, VA WAWA W50FBiiiiiiiiiiiVA v2021.1-MA CUSTOMIZATION LEVEL: C(1) BUILDING AUTOMATION SYSTEM (BAS) GENERAL CONTRACTOR TO INSTALL WATER METER(S) FOR B.A.S. PER PLUMBING DRAWINGS P5.0, AND PROVIDE UNDERGROUND CONDUIT TO EQUIPMENT #C3.2 SHOWN ON DRAWING EQ1.0. B.A.S. REFRIGERATION COMPANY INSTALLERS SHALL SUPPLY AND INSTALL B.A.S. AND CENTRAL WIRING PER CURRENT EDITION OF "BUILDING AUTOMATION SYSTEM 2010 (LITE) MASTER-BILT NEW STORES B.A.S. MASTER SPECS" BY HVAC CONCEPTS INC. AND AVAILABLE IN PLAN EXPRESS PROJECT FOLDER. GENERAL ABBREVIATION LEGEND B ANCHOR BOLT EDC ELECTRICAL DISTRIBUTION CENTER HSA HEADED STUD ANCHOR NTS NOT TO SCALE SCHED SCHEDULE CT ACOUSTICAL CEILING TILE EIFS EXTERIOR INSULATION AND FINISH SYSTEM INFO INFORMATION OC ON CENTER SDI STEEL DECK INSTITUTE FF ABOVE FINISH FLOOR EJ EXPANSION JOINT ISO ISOLATION OD OUTSIDE DIAMETER SIM SIMILAR ISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION EL ELEVATION JIBE JOIST BEARING ELEVATION OH OPPOSITE HAND Sill STEEL JOIST INSTITUTE ARCH ARCHITECTURAL ELEC ELECTRICAL JST JOIST PAF POWDER ACTUATED FASTENER SPECS SPECIFICATIONS ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS EQ EQUAL JT JOINT PCF POUNDS PER CUBIC FOOT STRUC STRUCTURAL AWS AMERICAN WELDING SOCIETY JES EQUIPMENT SUPPLIER I KSI KIPS PER SQUARE INCH PLAM PLASTIC LAMINATE T&B TOP AND BOTTOM BFF BELOW FINISHED FLOOR EW EACH WAY L LENGTH PLT PLATE THK THICKNESS BL BLOCK LINTEL EWH ELECTRIC WATER HEATER LEIS POUNDS PLF POUNDS PER LINEAR FOOT TO TOP OF BID BOTTOM OF FDN FOUNDATION LLH LONG LEG HORIZONTAL PMEJ PREMOLDED EXPANSION JOINT TOC/TC TOP OF CONCRETE BOS BOTTOM OF STEEL FF FINISHED FLOOR LLV LONG LEG VERTICAL PSF POUNDS PER SQUARE FOOT TOF TOP OF FOOTING BRG BEARING FRP FIBER REINFORCED PLASTIC LONG LONGITUDINAL PSI POUNDS PER SQUARE INCH TOGB TOP OF GRADE BEAM CJ CONTROL JOINT FS FAR SIDE MAX MAXIMUM P.T. PRESSURE TREATED TOM TOP OF MASONRY CL CENTERLINE FTG FOOTING MECH MECHANICAL PTD PAINTED TOP/TP TOP OF PAVING CLR CLEAR FV FIELD VERIFY MFR MANUFACTURER QTY QUANTITY T.O.R TOP OF ROOF RIDGE CMU CONCRETE MASONRY UNIT GA GAUGE MIN MINIMUM RE: REFER TO TOS TOP OF STEEL COL COLUMN GC GENERAL CONTRACTOR MISC MISCELLANEOUS REINF REINFORCING TRANS TRANSVERSE CONIC CONCRETE GM GENERAL MERCHANDISE MO MASONRY OPENING REQD REQUIRED UNO UNLESS NOTED OTHERWISE CONST CONSTRUCTION I GR IGROCERY MTL METAL REV REVERSE TYP TYPICAL CONT CONTINUOUS I GWB I GYPSUM WALL BOARD MR MOISTURE RESISTANT RO ROUGH OPENING VERT VERTICAL DIA DIAMETER IH I HEIGHT NO NUMBER RTU ROOF TOP UNIT W WIDTH ARCHITECT ARCHITECT CUHACI & PETERSON ARCHITECTS 2600 MAITLAND CENTER PARKWAY MAITLAND, FL 32751 PHONE 407-661-9100 FAX 407-661-9101 CONTACT GREG ANSBRO STRUCTURAL ENGINEER STRUCTURAL CUHACI & PETERSON ARCHITECTS ENGINEER 2600 MAITLAND CENTER PARKWAY MAITLAND, FL 32751 PHONE 407-661-9100 FAX 407-661-9101 CONTACT WILLIAM MATHERS, PROFESSIONAL ENGINEER MECHANICAL ENGINEER MECHANICAL CUHACI & PETERSON ARCHITECTS ENGINEER 2600 MAITLAND CENTER PARKWAY MAITLAND, FL 32751 PHONE 407-661-9100 FAX 407-661-9101 CONTACT JOSE J. DIAZ-VELAZQUEZ, PROFESSIONAL ENGINEER ELECTRICAL ENGINEER GAS CANOPY ENGINEER ELECTRICAL CUHACI & PETERSON ARCHITECTS GAS CANOPY CUHACI & PETERSON ARCHITECTS ENGINEER 2600 MAITLAND CENTER PARKWAY ENGINEER 2600 MAITLAND CENTER PARKWAY MAITLAND, FL 32751 MAITLAND, FL 32751 PHONE 407-661-9100 PHONE I 407-661-9100 FAX 407-661-9101 FAX 407-661-9101 CONTACT JAISON P. MORAS, CONTACT WILLIAM MATHERS, PROFESSIONAL ENGINEER PROFESSIONAL ENGINEER Mo O O 0 w `L a w IY O c0 o J Q a m Q � � C Q CD o Q CV > Lu Q � L J w - EE > m CD Co LU O CD U O N U �C/) Of a F- LU Lu U) L\u w / OF w U co LTH OF Gln O� C2 w J 0 EP U F NG o 00 w x ��cHITEG� a 05/11/2022 N 0 N � N 4f d t U) C 0 0 •Ln u w DO � � F of a i O Z N N O o WQ W o Z Y O N O w W m K a In 0 0 all GENERAL A. THESE GENERAL NOTES ARE NOT INTENDED TO REPLACE SPECIFICATIONS. SEE SPECIFICATIONS FOR REQUIREMENTS IN ADDITION TO GENERAL NOTES. B. NOT ALL EXISTING CONDITIONS, PROPOSED CONDITIONS, OR UTILITIES ARE SHOWN ON THE STRUCTURAL DRAWINGS. COORDINATE STRUCTURAL WORK WITH THE WORK OF OTHER TRADES. IN CASE OF CONFLICT, NOTIFY THE ENGINEER OF RECORD. C. THE STRUCTURE HAS BEEN DESIGNED TO RESIST DESIGN LOADS ONLY AS A COMPLETE STRUCTURE. APPLICATIONS OF CONSTRUCTION LOADS TO THE PARTIALLY COMPLETED STRUCTURE SHALL BE CONSIDERED AND SO INCLUDED IN THE DESIGN OF SHORING, BRACING, FORMWORK, AND STRUCTURE DURING ERECTION AND UNTIL ALL PERMANENT CONNECTIONS ARE MADE. TEMPORARY BRACING FOR THE STRUCTURE MUST BE PROVIDED IN ALL DIRECTIONS. D. ONLY USE DIMENSIONS INDICATED ON THE DRAWINGS. DO NOT SCALE DRAWINGS. E. ELEVATIONS INDICATED ON THE STRUCTURAL DRAWINGS ARE BASED ON A PROJECT DATUM INDICATED ON THE ARCHITECTURAL DRAWINGS. DESIGN CRITERIA: A. 2018 VIRGINIA CONSTRUCTION CODE B. ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES C. ACI 318-19, STRUCTURAL CONCRETE BUILDING CODE D. AISC MANUAL OF STEEL CONSTRUCTION, 15TH EDITION E. AISI 2016 COLD FORMED STEEL DESIGN MANUAL F. NDS-18, NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION G. SERVICEABILITY AND DEFLECTION CRITERIA PER GOVERNING COMPONENT DESIGN STANDARD DELEGATED ENGINEERING: THE FOLLOWING SYSTEMS REQUIRE DELEGATED ENGINEERING. REVIEW SPECIFICATIONS FOR SUBMITTAL REQUIREMENTS. A. COLD -FORMED METAL FRAMING AND TRUSSES. B. STRUCTURAL STEEL - CONNECTIONS. C. STEEL OPEN WEB JOISTS. D. ACCESS LADDER. E. GATES, DOORS AND FENESTRATION SYSTEMS. DESIGN LOADING: A. ROOF LIVE LOADS: 20 PSF B. ROOF SUPERIMPOSED DEAD LOAD: 13 PSF C. SNOW LOADING: 1. GROUND SNOW LOAD, PG: 30 PSF 2. FLAT -ROOF SNOW LOAD, PF: 21 PSF 3. SNOW EXPOSURE FACTOR, CE: 1.00 4. SNOW LOAD IMPORTANCE FACTOR, IS: 1.00 5. THERMAL FACTOR, CF: 1.00 6. SNOW DRIFT LENGTH, SDL: 101-0" 7. SNOW DRIFT LOAD, SD: 45.5 PSF D. WIND LOADING 1. ULTIMATE DESIGN WIND SPEED, VULT: 115 MPH 2. NOMINAL WIND SPEED VASD: 90 MPH 3. RISK CATEGORY (TABLE 1.5-1, ASCE 7): II 4. WIND EXPOSURE: C 5. ENCLOSURE CLASSIFICATION: ENCLOSED (+/-0.18) 6. COMPONENT AND CLADDING: SEE CHARTS THIS SHEET 7. NET UPLIFT LOADING (ASD - STEEL JOIST) SEE THIS SHEET FOR C&C WIND PRESSURES. USE 10PSF MAX. DEAD LOAD FOR UPLIFT CALCULATIONS. USE 22PSF MIN. UPLIFT LOAD E. SEISMIC LOADING (DESIGN CATEGORY AND CLASS) 1. RISK CATEGORY: II 2. SEISMIC IMPORTANCE FACTOR: 1.0 3. MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS a. SS: 0.212 g b. S1: 0.058 g 4. SITE CLASS: D 5. DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS a. SDS: 0.226 g b. SD1: 0.093 g 6. SEISMIC DESIGN CATEGORY: B 7. BASIC SEISMIC FORCE -RESISTING SYSTEM(S):UGHT FRAMED WALLS W/ SHEATHING 8. DESIGN BASE SHEAR(S): 9.0 KIPS 9. SEISMIC RESPONSE COEFFICIENT, CS: .035 10. RESPONSE MODIFICATION COEFFICIENT(S), R 6.5 11. ANALYSIS PROCEDURE USED: ASCE 7-16 EQUIV LATERAL METHOD F. FLOOD DESIGN DATA: NOT APPLICABLE G. DESIGN LOAD -BEARING VALUES OF SOIL: 3000 PSF 01003 SUBMITTALS A. SEE SECTION 01003-3 IN THE PROJECT MANUAL AND SPECIFICATIONS FOR THE LIST OF REQUIRED STRUCTURAL SUBMITTALS / SHOP DRAWINGS. B. IN ADDITION TO THE SUBMITTALS LISTED IN THE PROJECT MANUAL AND SPECIFICATIONS, THE FOLLOWING SHOP DRAWINGS ARE REQUIRED: 1. PREFABRICATED LIGHT GAUGE METAL ROOF TRUSSES. 2. CLIPS, SCREWS, BOLTS, AND FASTENER PRODUCT SHEETS. 3. SEE SECTION 01002-14 "SHOP DRAWINGS SUBMITTAL" IN THE PROJECT MANUAL AND SPECIFICATIONS FOR SUBMITTAL RESPONSIBILITIES AND REQUIREMENTS. 02001 EARTHWORK I FOUNDATION A. FOUNDATION DESIGN IS BASED UPON THE FOLLOWING SOILS REPORT: COMPANY NAME: ECS MID -ATLANTIC, LLC DATE: SEPTEMBER 15, 2020 PROJECT NO: 28:2465 THE DESIGN ALLOWABLE SOIL BEARING PRESSURE IS LISTED IN THE DESIGN LOADING CRITERIA. B. SEE SECTION 02001-04 IN THE PROJECT MANUAL AND SPECIFICATIONS FOR EARTHWORKS TO INCLUDE BUT NOT LIMITED TO: 1. PREPARING AND GRADING SUBGRADES FOR SLABS -ON -GRADE 2. EXCAVATING AND BACKFILLING FOR BUILDINGS AND STRUCTURES 3. DRAINAGE AND MOISTURE - CONTROL FILL COARSE FOR SLABS -ON -GRADE 4. EXCAVATING AND BACKFILLING TRENCHES WITHIN BUILDING LINES 5. MATERIAL, INSPECTION, AND TESTING REQUIREMENTS C. ANY FILL REQUIRED TO BACKFILL EXCAVATED AREA OR ACHIEVE FINISHED GRADE IN STRUCTURAL AREAS SHALL BE AS INDICATED BY GEOTECHNICAL ENGINEER. THE FILL SHALL BE PLACED IN LEVEL LIFTS NOT EXCEED 12" LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF THE SOIL'S MODIFIED PROCTOR MAXIMUM DRY DENSITY AS DETERMINED BY ASTM SPECIFICATION D-1557. D. IN -PLACE DENSITY TESTS SHALL BE PERFORMED BY AN EXPERIENCED ENGINEERING TECHNICIAN. TESTS SHALL BE PERFORMED FOR EACH 2,000 SQUARE FEET, IN EVERY COLUMN FOOTING LOCATION AND EACH 50'-0" ALONG WALL FOOTINGS. COPIES OF THE TEST REPORTS SHALL BE FURNISHED TO THE STRUCTURAL ENGINEER. E. REMOVE FREE WATER FROM EXCAVATIONS BEFORE PLACING CONCRETE. WATER TABLE ASSUMED BELOW 6-0" PRECLUDING BUOYANCY CONDITIONS ON FOOTINGS. F. CAUTION SHOULD BE USED WHEN OPERATING VIBRATORY COMPACTING EQUIPMENT NEAR THE EXISTING STRUCTURE TO AVOID THE RISK OF DAMAGE TO THE STRUCTURE. G. REFER TO ARCHITECTURE DRAWINGS FOR ANY NECESSARY WATERPROOFING REQUIREMENTS. 03301 CAST -IN -PLACE CONCRETE A. SEE SECTION 03301 IN THE PROJECT MANUAL AND SPECIFICATIONS TO INCLUDE BUT NOT LIMITED TO: 1. GENERAL REQUIREMENTS a. SUBMITTALS b. QUALITY ASSURANCE / CODE REQUIREMENTS 2. PRODUCT / MATERIAL REQUIREMENTS 3. EXECUTION OF WORK REQUIREMENTS a. SHORING b. VAPOR RETARDER c. JOINTS d. PLACEMENT/FINISHING e. CURING 4. QUALITY CONTROL -TESTING REQUIREMENTS B. SUMMARY OF PROJECT MANUAL AND SPECIFICATIONS SECTION 03301-02 PRODUCTS: 1. CONCRETE STRENGTH: 4,000 PSI 2. STEEL REINFORCEMENT: 60 KSI 3. SLAB REINFORCEMENT: FIBER MESH 3LB PER CUBIC YARD C. LAP SPLICE REINFORCEMENT LENGTH = 44 x BAR DIAMETER 04200 UNIT MASONRY A. SEE SECTION 04200 IN THE PROJECT MANUAL AND SPECIFICATIONS TO INCLUDE BUT NOT LIMITED TO: 1. GENERAL REQUIREMENTS a. SUBMITTALS b. MATERIAL REQUIREMENTS c. HOT -WEATHER AND COLD -WEATHER REQUIREMENTS 2. PERFORMANCE REQUIREMENTS a. MASONRY COMPRESSIVE STRENGTH (fm): 1,500-PSI 3. PRODUCTS 4. EXECUTION 5. FIELD QUALITY CONTROL B. SUMMARY OF PROJECT MANUAL AND SPECIFICATIONS SECTION 04200-03 PRODUCTS: 1. CONCRETE MASONRY UNITS: ASTM C 90 - NORMAL WEIGHT, TYPE (1) MOISTURE CONTROLLED 2. MORTAR: ASTM C 270, TYPE S 3. GROUT: ASTM C476, COARSE (MIN. 2,000-PSI) 4. STEEL REINFORCING BARS: ASTM A 615 - GRADE 60 5. MASONRY JOINT REINFORCEMENT: ASTM A 951 HOT -DIP GALVANIZED CARBON STEEL WIRE C. LAP SPLICE REINFORCEMENT IN CMU LENGTH = 28 INCHES (#5 BARS). 05120 STRUCTURAL STEEL A. SEE SECTION 05120 IN THE PROJECT MANUAL AND SPECIFICATIONS TO INCLUDE BUT NOT LIMITED TO: 1. GENERAL REQUIREMENTS a. FABRICATOR REQUIREMENTS b. SUBMITTALS c. CODE REQUIREMENTS 2. PRODUCT / MATERIAL REQUIREMENTS 3. PAINTING REQUIREMENTS 4. EXECUTION OF WORK REQUIREMENTS a. FABRICATION b. ERECTION 5. QUALITY ASSURANCE REQUIREMENTS (INSPECTIONS & TESTING) B. SUMMARY OF PROJECT MANUAL AND SPECIFICATIONS 05120 PRODUCTS: 1. MATERIALS: a. W SHAPES: ASTM A992 (50 KSI) b. TUBE SHAPES ASTM A500 GR. C (50 KSI) c. CHANNELS AND ANGLES: ASTM A36 (36 KSI) d. PLATES: ASTM A36 (36 KSI) e. BOLTS: ASTM A 325 f. ANCHOR BOLTS/RODS: ASTM F 1554, GRADE 36 g. ANCHOR BOLT WASHERS: ASTM F 844 h. ELECTRODES FOR WELDING: AWS CODE E70XX C. TEMPLATES SHALL BE PROVIDED FOR ALL ANCHOR BOLTSIRODS CAST IN CONCRETE. D. GALVANIZE STEEL MEMBERS INDICATED ON PLANS: 1. GALVANIZE STEEL MEMBERS, FABRICATIONS AND ASSEMBLIES AFTER FABRICATION BY THE HOT -DIP PROCESS IN ACCORDANCE WITH ASTM A 123. 2. COATING REQUIREMENTS: a. CONFORM TO PARAGRAPH 6.1 OF ASTM A 123, TABLE 1 OF ASTM A 153, OR TABLE 2 OF ASTM A 767 AS APPROPRIATE. b. SURFACE FINISH: CONTINUOUS, ADHERENT, AS SMOOTH AND EVENLY DISTRIBUTED AS POSSIBLE AND FREE FROM ANY DEFECT DETRIMENTAL TO THE END USE OF THE COATED ARTICLE c. ADHESION: WITHSTAND NORMAL HANDLING CONSISTENT WITH THE NATURE AND THICKNESS OF THE COATING AND NORMAL USE OF THE ARTICLE. 3. REPAIR OF DAMAGED COATING: REPAIR DAMAGED AREAS BY WELDING, FLAME CUTTING OR DURING HANDLING, TRANSPORT OR ERECTION BY ONE OF THE APPROVED METHODS IN ACCORDANCE WITH ASTM A 780 WHENEVER DAMAGE EXCEEDS 3/16" IN WIDTH. MINIMUM THICKNESS REQUIREMENTS FOR THE REPAIR ARE THOSE DESCRIBED IN ASTM A 123 SECTION 6.2, CURRENT EDITION. E. GROUT UNDER BEARING PLATES SHALL BE NON-METALLIC, NON -SHRINK TYPE WITH A COMPRESSIVE STRENGTH OF AT LEAST 6000 PSI WHEN BEARING ON 3000 PSI CONCRETE AND 8000 PSI WHEN BEARING ON 4000 PSI CONCRETE. 05210 STEEL JOISTS A. SEE SECTION 05120 IN THE PROJECT MANUAL AND SPECIFICATIONS TO INCLUDE BUT NOT LIMITED TO: 1. GENERAL REQUIREMENTS - STEEL JOISTS a. SUBMITTALS b. QUALITY ASSURANCE -REFERENCE SPECIFICATION REQUIREMENTS c. DELIVERY, STORAGE, AND HANDLING REQUIREMENTS 2. PRODUCT / MATERIAL REQUIREMENTS a. JOISTS, BRIDGING, AND ACCESSORIES b. PAINTING 3. EXECUTION OF WORK REQUIREMENTS a. INSTALLATION 4. QUALITY ASSURANCE REQUIREMENTS (INSPECTIONS & TESTING) B. ALL JOISTS SHOWN IN THE PLANS ARE MINIMUM SIZES. DEPTH CANNOT BE INCREASED WITHOUT WRITTEN APPROVAL FROM ENGINEER OF RECORD. C. STEEL JOIST FRAMING SHALL BE DESIGNED PER THE LOADING SHOWN ON THIS SHEET AND SHEET S3.0. D. DIAGONAL BRIDGING / BRACING SHALL BE BETWEEN ADJACENT JOISTS WHENEVER BOTTOM CHORD HORIZONTAL BRIDGING IS DISCONTINUOUS. 05310 STEEL DECK A. REFER TO ROOF PLAN FOR METAL DECK SIZE AND ATTACHMENT INFORMATION. B. SEE SECTION 05310 IN THE PROJECT MANUAL AND SPECIFICATIONS TO INCLUDE BUT NOT LIMITED TO: 1. GENERAL REQUIREMENTS a. SUBMITTALS b. QUALITY ASSURANCE- REFERENCE SPECIFICATION REQUIREMENTS 2. PRODUCT / MATERIAL REQUIREMENTS 3. EXECUTION OF WORK REQUIREMENTS a. INSTALLATION b. ACCESSORIES c. GALVANIZING REPAIR 4. QUALITY ASSURANCE REQUIREMENTS (INSPECTIONS & TESTING) 05400 COLD -FORMED METAL FRAMING A. SEE SECTION 05400 IN THE PROJECT MANUAL AND SPECIFICATIONS TO INCLUDE BUT NOT LIMITED TO: 1. GENERAL REQUIREMENTS a. STRUCTURAL PERFORMANCE b. SUBMITTALS c. QUALITY ASSURANCE -REFERENCE SPECIFICATION REQUIREMENTS 2. PRODUCT / MATERIAL REQUIREMENTS a. STEEL REQUIREMENTS b. WALL FRAMING c. JOIST FRAMING d. FABRICATION e. FASTENERS AND ACCESSORIES f. REPAIR PAINTING 3. EXECUTION OF WORK REQUIREMENTS a. INSTALLATION 1. GENERAL 2. TOLERANCES 3. LOAD -BEARING WALL 4. CURTAIN -WALL 5. JOIST INSTALLATION b. REPAIRS B. ALL FRAMING SHOWN IN THE PLANS ARE MINIMUM SIZES. DIMENSIONS CANNOT BE INCREASED WITHOUT WRITTEN APPROVAL FROM ENGINEER OF RECORD. C. PRE-ENGINEERED ROOF TRUSSES SHALL BE DESIGNED PER THE LOADING SHOWN IN DESIGN LOADING - THIS SHEET. D. PRE-ENGINEERED ROOF TRUSSES SHALL BE DELIVERED, HANDLED, BRACED, AND INSTALLED PER AISI S214-07. E. ALL CLIPS AND FASTENING HARDWARE SHALL BE TESTED AND RATED FOR THE LOAD RESISTED. F. LIGHT GAUGE FRAMING SYSTEMS INCLUDING TRUSS SYSTEMS SHALL INCLUDE ALL NECESSARY PARTS AND ACCESSORIES, TEMPORARY AND PERMANENT, AS REQUIRED TO FORM A COMPLETE SYSTEM (ANCHORAGE INCLUDED). 06100 ROUGH CARPENTRY 1 SHEATHING A. SEE SECTION 06100 IN THE PROJECT MANUAL AND SPECIFICATIONS TO INCLUDE BUT NOT LIMITED TO: 1. PRODUCT / MATERIAL REQUIREMENTS a. LUMBER, GENERAL b. WOOD -PRESERVATIVE -TREATED MATERIALS c. DIMENSIONAL LUMBER: APPROVED GRADES AND SPECIES d. WOOD -BASED STRUCTURAL USE PANELS e. FASTENERS AND ANCHORS 2. EXECUTION OF WORK REQUIREMENTS a. INSTALLATION 1. TOLERANCES 2. FRAMING CONNECTION REQUIREMENTS a. "RECOMMENDED NAILING SCHEDULE" AFPA's NDS FOR WOOD CONSTRUCTION b. INTERNATIONAL BUILDING CODE TABLE 2304.9.1 3. FASTENER COATING REQUIREMENTS 4. REQUIRED PRACTICE STANDARDS REFERENCES a. AMERICAN PLYWOOD ASSOCIATION E30 b. AMERICAN PLYWOOD ASSOCIATION T625 WOOD STRUCTURAL PANELS OVER METAL FRAMING B. WALL SHEATHING: APA RATED SHEATHING, EXTERIOR (C-C GRADE) 1. PANEL GRADE AND PERFORMANCE CATEGORY: STRUCTURAL 1: 5/8" PERFORMANCE CATEGORY 2. SPAN RATING: 40/20 3. BLOCKING: 2" WIDE 43 MIL STRAPPING 4. SHEATHING SHOULD BE PLACED PERPENDICULAR TO SUPPORTS C. ROOF SHEATHING: APA RATED SHEATHING, EXTERIOR (C-C GRADE) 1. NOMINAL THICKNESS: 518" 2. SPAN RATING: 40120 3. SHEATHING SHOULD BE PLACED PERPENDICULAR TO SUPPORTS D. PARAPET SHEATHING: APA RATED SHEATHING, EXTERIOR (C-C GRADE) 1. PANEL GRADE AND PERFORMANCE CATEGORY: STRUCTURAL 1: 5/8" PERFORMANCE CATEGORY 2. SPAN RATING: 40/20 3. SHEATHING SHOULD BE PLACED PERPENDICULAR TO SUPPORTS E. FASTENERS 1. GENERAL: PROVIDE FASTENERS OF SIZE AND TYPE INDICATED THAT COMPLY WITH REQUIREMENTS SPECIFIED IN THIS ARTICLE FOR MATERIAL AND MANUFACTURE. 2. SCREWS FOR FASTENING WOOD STRUCTURAL PANELS TO COLD -FORMED METAL FRAMING: ASTM C 954, EXCEPT WITH WAFER HEADS AND REAMER WINGS, LENGTH AS RECOMMENDED BY SCREW MANUFACTURER FOR MATERIAL BEING FASTENED. F. COORDINATE WALL, PARAPET, AND ROOF SHEATHING INSTALLATION WITH FLASHING AND JOINT - SEALANT INSTALLATION SO THESE MATERIALS ARE INSTALLED IN SEQUENCE AND MANNER THAT PREVENT EXTERIOR MOISTURE FROM PASSING THROUGH COMPLETED ASSEMBLY. G. COORDINATE SHEATHING INSTALLATION WITH INSTALLATION OF MATERIALS INSTALLED OVER SHEATHING SO SHEATHING IS NOT EXPOSED TO PRECIPITATION OR LEFT EXPOSED AT END OF THE WORKDAY WHEN RAIN IS FORECAST. H. ALL PANELS (GENERAL): 1. IDENTIFICATION REQUIREMENTS: EACH PANEL SHALL BE IDENTIFIED WITH THE APPROPRIATE TRADEMARK OF APA. 2. ALL PANELS HAVING ANY EDGE OR SURFACE EXPOSED LONG TERM TO WEATHER SHALL BE CLASSIFIED EXTERIOR. 3. PANEL PERFORMANCE CATEGORY, GRADE, AND GROUP NUMBER OR SPAN RATING SHALL BE AT LEAST EQUAL TO THAT SHOWN ON THE DRAWINGS. APPLICATION SHALL BE IN ACCORDANCE WITH APA. 4. 1/8" SPACING REQUIRED AT ALL PANEL ENDS AND EDGES. J. ROOF SHEATHING: 1. INSTALL WITH LONG DIMENSION OR STRENGTH AXIS OF THE PANEL ACROSS SUPPORTS. 2. FASTEN TO LIGHT GAUGE METAL TRUSSES USING #10 SELF DRILLING SCREWS AT 6" OC ALONG UNSUPPORTED EDGES AND 12" OC AT INTERMEDIATE FRAMING MEMBERS. PROVIDE ONE PLYWOOD CLIP PER SPAN BETWEEN SHEET EDGES. K. WALL/ PARAPET SHEATHING: 1. APPLY WEATHER -RESISTANT BARRIER OVER PANEL WALL SHEATHING. 09960 COATINGS FOR STEEL A. REFER TO SPECIFICATIONS FOR GENERAL REQUIREMENTS, PRODUCTS, AND EXECUTION OF WORK. B. ASPHALTIC BASED CORROSION RESISTANCE COATING SHALL BE MADE WITH AN ASPHALT -BASE EMULSION COATING SYSTEM PER ASTM D 1187. C. APPLY A MINIMUM 1/16" THICK COATING IN TWO APPLICATIONS. D. COATING TO BE APPLIED ON ALL SIDES OF MEMBERS - TO INCLUDE STEEL TO BE ADJACENT TO CAST -IN - PLACE CONCRETE. E. COAT STRUCTURAL ANCHOR BOLTS, WELDS, AND ALL COMPONENTS IN THE AFFECTED AND DEFINED AREA. F. ALL STEEL AND STEEL COMPONENTS (I.E., BASE PLATES AND ANCHOR BOLTS) EXPOSED TOP SOIL SHALL BE COATED FROM THE FOUNDATION (LOWEST LEVEL) UP TO 6" ABOVE THE SLAB OR FINAL GRADE - WHICHEVER IS GREATER. 0 a ch ® c+) ® 0 e ®® 7 0 m (h ® (7 ROOF PRESSURES ALLOWABLE (ASD) WIND PRESSURES (ASCE 7-16) FOR COMPONENTS AND CLADDING EFFECTIVE ZONE ZONE2e ZONE2r ZONE ZONE ZONE AREA (SQFT) POS NEG POS NEG POS NEG POS NEG POS NEG POS NEG 10 15 PSF -26 PSF 15 PSF -30 PSF 15 PSF -31 PSF 15 PSF -37 PSF 21 PSF -23 PSF 21 PSF -28 PSF 20 13 PSF -23 PSF 13 PSF -27 PSF 13 PSF -28 PSF 13 PSF -30 PSF 20 PSF -22 PSF 20 PSF -26 PSF 50 11 PSF -19 PSF 11 PSF -22 PSF 11 PSF -24 PSF 11 PSF -21 PSF 19 PSF -20 PSF 19 PSF -23 PSF A > 100 10 PSF -16 PSF 10 PSF -18 PSF 10 PSF -21 PSF 10 PSF -21 PSF 18 PSF -20 PSF 18 PSF -22 PSF NOTES: 1. ROOF OVERHANG PRESSURES: a. ZONE 2e OH: +16 PSF AND -41 PSF b. ZONE 3 OH: +16 PSF AND -47 PSF 2. "a" DENOTES EDGE STRIP = 3'- 0". 3. POSITIVE & NEGATIVE SIGNS SIGNIFY PRESSURES ACTING TOWARDS AND AWAY FROM THE BUILDING SURFACES, RESPECTIVELY (FULL HEIGHT, U.N.O.). 4. WIND PRESSURES INDICATED ABOVE ARE ALLOWABLE STRESS DESIGN WIND PRESSURES. DIVIDE THE PRESSURES BY A FACTOR OF 0.6 TO OBTAIN STRENGTH DESIGN WIND PRESSURES. LIST OF STRUCTURAL ABBREVIATIONS AB ANCHOR BOLTS MATL MATERIAL ADDL ADDITIONAL MAX MAXIMUM ALT ALTERNATE MB MASONRYBEAM ANCH ANCHOR MC MOMENT CONNECTION APPROX APPROXIMATE MC MASONRY COLUMN ARCH ARCHITECT/ARCHITECTURAL MCJ MASONRY CONTROL JOINT BE BOND BEAM MECH MECHANICAL BLDG BUILDING MEZZ MEZZANINE BM BEAM MFR MANUFACTURE/MANUFACTURERS BO BOTTOM OF MIN MINIMUM BOT/BTM BOTTOM MISC MISCELLANEOUS BP BASE PLATE/BEARING PLATE MTL METAL BRG BEARING NIC NOT IN CONTRACT BTW BETWEEN NOM NOMINAL CANT CANTILEVER NTS NOT TO SCALE CB CONCRETE BEAM OC ON CENTER CC CONCRETE COLUMN OPNG OPENING CIP CAST IN PLACE OPP OPPOSITE CJ CONTROL JOINT PB PARAPET BEAM (MASONRY) CL CENTERLINE PCC PRECAST CONCRETE CLR CLEAR/CLEARANCE PL PLATE COL COLUMN PLF POUNDS PER LINEAR FOOT CONC CONCRETE PLY PLYWOOD CONNX CONNECTION PRE-ENG PRE-ENGINEERED CONSTR CONSTRUCTION PEMB PRE-ENGINEERED METAL BUILDING CONT CONTINUOUS PRE-FAB PRE -FABRICATED CORR CORRUGATED PRELIM PRELIMINARY CMU CONCRETE MASONRY UNIT PROJ PROJECTION DET DETAIL PSF POUNDS PER SQUARE FOOT DIA/DIAM DIAMETER PSI POUNDS PER SQUARE INCH DIM DIMENSION PT PRESSURE TREATED DIST DISTANCE PT POST TENSION(ING) (ED) DN DOWN PW PANEL WIDTH DR DRAIN RAD RADIUS DWG DRAWING RB ROOF BEAM (MASONRY) DWL DOWEL RCP REINFORCED CONCRETE PIPE EA EACH RD ROOF DRAIN EE EACH END REF REFERENCE EF EACH FACE REINF REINFORCING EJ EXPANSION JOINT REQ'D REQUIRED EUELEV ELEVATION REV REVISION ELECT ELECTRICAL RTU ROOF TOP UNIT EMB EMBEDMENT RW RETAINING WALL ENGR ENGINEER SECT SECTION EQ EQUAL SCHtSCHED SCHEDULE EQUIP EQUIPMENT SIM SIMILAR EQUIV EQUIVALENT SP/SPC SPACE(S) ES EACH SIDE SPECS SPECIFICATIONS EXIST EXISTING SQ SQUARE EXP EXPANSION SS STAINLESS STEEL EXT EXTERIOR STD STANDARD EW EACH WAY ST/STL STEEL FAB FABRICATE STRUC STRUCTURAL FD FLOOR DRAIN SYM SYMMETRICAL FDN FOUNDATION T & B TOP AND BOTTOM FF FINISHED FLOOR T & G TONGUE AND GROOVE FIN FINISH(ED) TE THICKENED EDGE FUFLR FLOOR THK THICK FTG FOOTING THRD THREAD(ED) GA GAGE/GAUGE TB TIE BEAM GALV/GV GALVANIZED TOC TOP OF CONCRETE GC GENERAL CONTRACTOR TOM TOP OF MASONRY HAS HEADED ANCHOR STUD TOS TOP OF STEEL HE HIGH BEAM (MASONRY) TYP TYPICAL HORIZ HORIZONTAL TS TUBE STEEL HSB HIGH STRENGTH BOLTS UNO UNLESS NOTED OTHERWISE HSS HOLLOW STEEL SECTION UON UNLESS OTHERWISE NOTED HT HEIGHT VERT VERTICAL INT INTERIOR VIF VERIFY IN FIELD JST JOIST W WIDE FLANGED JT JOINT WB WALL BEAM (TILT) K KIPS WC WALL COLUMN (TILT) KO KNOCKOUT W/ WITH KSF KIPS PER SQUARE FOOT W/0 WITHOUT KSI KIPS PER SQUARE INCH WD WOOD L ANGLE WGT WEIGHT LB LOW BEAM (MASONRY) WH WEEPHOLE LBS POUNDS WP WORKING POINT LD DEVELOPMENT LENGTH WT STEEL TEE SECTION LDH LONG DIMENSION HORIZONTAL WWF WELDED WIRE FABRIC LDV LONG DIMENSION VERTICAL @ AT LGTH LENGTH & AND LLBB LONG LEG BACK TO BACK LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL N 0.60.6h III 3 ® 2 ® 1 O O O h ® 2 1 1' 1 2 O a 1 �Y WALL PRESSURES ROOF PRESSURES ALLOWABLE (ASD) WIND PRESSURES FOR COMPONENTS & CLADDING (ASCE 7-16) EFFECTIVE AREA ZONE V ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 4 PARAPET ZONE 5 ZONE 5 PARAPET (SQ FT) POS NEG POS NEG POS NEG POS NEG POS NEG CASE A CASE B POS NEG CASE A CASE B 10 10 PSF -19 PSF 10 PSF -33 PSF 19 PSF -43 PSF 19 PSF -43 PSF 18 PSF -21 PSF 52 PSF -27 PSF 18 PSF -25 PSF 52 PSF -35 PSF 20 10 PSF -19 PSF 10 PSF -31 PSF 18 PSF -41 PSF 18 PSF -41 PSF 18 PSF -20 PSF 18 PSF -24 PSF 50 10 PSF -19 PSF 10 PSF -28 PSF 17 PSF -37 PSF 17 PSF -37 PSF 18 PSF -19 PSF 18 PSF -21 PSF A ? 100 10 PSF -19 PSF 10 PSF -26 PSF 16 PSF -34 PSF 16 PSF -34 PSF 18 PSF -18 PSF 18 PSF -20 PSF NOTES: 1. PARAPET WIND PRESSURES: CASE A= PRESSURES TOWARD THE BUILDING. CASE B = PRESSURES AWAY FROM THE BUILDING. 2. "P" DENOTES PARAPET PRESSURE VALUES. 3. "a" DENOTES EDGE STRIP = T-0" 4. "0.6h" DENOTES ROOF ZONE 3 EDGE STRIP=10'-0" 5. "0.2h" DENOTES ROOF ZONE 3 EDGE STRIP WIDTH = 4'-0" 6. POSITIVE & NEGATIVE SIGNS SIGNIFY PRESSURES ACTING TOWARDS AND AWAY FROM THE BUILDING SURFACES, RESPECTIVELY (FULL HEIGHT, UNLESS NOTED). 7. WIND PRESSURES INDICATED ABOVE ARE ALLOWABLE STRESS DESIGN WIND PRESSURES. DIVIDE THE PRESSURES BY A FACTOR OF 0.6 TO OBTAIN STRENGTH DESIGN WIND PRESSURES Lu Y d Lu CC O coo � o Q ~ rn d z m Q w 3: U N Q N O Q � N > LLI Q Of J > m LL co CO w co Of O Lu 0 of _ U O N 0 0 N a U) Lu 0 z J Q Lu w z J LLI � fn w V w x �4;O��tiPLTH OpLrG' p� LIAM S MP�Tf IERS y AL m 3 N N 0 N N � c c g O +• 'y N W c� a- a d 2 O N Z N N LL G LL U �`+ �o Y W O O 7 � Q Lu 0 N O q (� W (n Q Ic a o c=i S1.0 2.6 PROVIDE 4'-0" CLEAR OPENING FOR UTILITIES / 20 - 4" CONDUIT AS REQUIRED IN WALL. PROVIDE (2) 20' - 61/2" 90'-4314" 17' - 0 3/4" 4 XS X5-0 PRECAST LINTELS ONE COURSE ABOVE TOP OF FOOTING WITH 8" BEARING EACH F80X50 2 END. GROUT SOLID AFTER CONDUIT 8" INSTALLATION (NOT BELOW SHEARWALL HSS5X5X5(16 1 2 1 ANCHOR). P3 BP2 9 5/8" 9 5/ " COORDINATE WITH CIVIL; DO NOT INSTALL AT S6.0 SHEAR WALL LOCATIONS 2'-6' 4'-0" 2'-6" 4'-0" 3 m 0'-4" 6 S6.0 S7.3 A CLR � I I I SS5X5X5116 HSS5X5X5/16 1 1 7 HSS5X5X51i6 r _ F 0 P1 BP2 P, BP274� S7.2 F40 P1 BPi 4 _ F24 - - � J L - - -WF24- - - - - - WF24 - - - B- - -- - - - --- - --- - - - --- -- C Mal 0 0 n FOUNDATION PLAN 3/16" = 1'-O" S7.2 ~ ROOF LADDER, g -0'�" - JAMB - SEE ARCH DWGS 7 SHEARWALL'T REQUIRES " 5l8" SHEATHING BOTH I S7 2 SIDES OF WALL 1-8" 9'-5" 17-0112" i I � 2 S6.0 I SEE NOTE 9 9 1 10 S6.0 S6.0 CONTROL JNTS REQDAT REFRIGERATOR/FRE 1/3 POINTS ALONG FREEZER SEE NOTE 7 1 I EDGE 1 S5.0 li SHEARWALL'2' REQUIRES 5l8" SHEATHING BOTH 1 SIDES OF WALL 1 II I C.J., TYP I 1 I I 1 LLu SEE NOTE 6 �I a 0'-0• I �1 I w T .0 SLAB I I I I I B S6.0 (9) EQ SPACES II I � I 32' - 5112" I r-F80X50 / HSS5X5X5/16 15 P3 BP2 S7.3 HSS5X5X5/16 2 7 Pi BP2 S5.0 17 S7.2 _ ROLLUP DOOR S6. 014" FRAMING HSS5X5X51i6 - - - - 6 WF24- - - F40 P1 BPi REFRIGERATOR/FREEZER LOCATIONS: I SEE NOTE 7 20' -10' I I 8'-6" 1 10 S5.0 IS I I� 17-4" z s6.o `o III I 17-5" HSS9X5X318 4' - 3" F76 BP3A \ 7 J L � o r , S7.2 F_ I Ili HSS5X5X318 S6.0 F60 P1 BP4 - -- 1 L� IrF� L HSS5X5X5/16 7 I F40 P1 I BP4 - - S7.2 ----- �_-__ - - - - _ - - - - - - - - - - j - - - - - - - - - - - - - - - - - - - - i - - - - - - - - - - - - - - - - HSS5X5X5116 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - F30 Pi BP2A 11 WF24 7-0" - - - - �- - I HSS4X4Xilti I 1 S6.0 o I m 0 I I L HSS5X5X318 F60 P1 BP4 I ~LIL --TYP 3 L F- -1 S6.0 ICI I I I III I N I SS4X4X1/4 1 7-8" 2'-8" F30 P1 BP2 � III F30I Pi IBP2A H1 F30 P1 BP2 10 ,0 HSS12XSX5116 1 I HSS12X8X5116 HSS5X5X5116 F401 25I 2 F30 BP F_ - -I F_ - -1 F40 P2 BP2 , F_ - -1 F - -1 t -1 F30 BP3B - - - -�L L J - - -1 - L - J 4 L L - J L JI S5.0 L � 4 3 S5.0 0'-4" l'-83/4'� - 0'-4" S5.0 I I I l' - 6 4„ 3N -1 1/2" 20' - 41/4' 32' - 3" I I I 1 1.1 1.2 3 4 5 WMEM FOUNDATION GENERAL NOTES 1. COORDINATE LOCATIONS OF REFRIGERATOR AND FREEZER PADS WITH ARCH DRAWINGS. 2. ELEVATION LEVELS INDICATED ON THE DRAWING ARE BASED ON A PROJECT DATUM INDICATED IN THE ARCH DRAWINGS. 3. CONCRETE CURING COMPOUNDS AND SEALERS ARE NOT PERMITTED FOR THE BUILDING SLAB. 4. PLACEMENT OF CONCRETE SLAB ON GRADE TO MEET THE FOLLOWING CRITERIA: LEVEL WITHIN 1%, FLAT WITHIN 1l4" AS MEASURED IN 10'-0". 5. ALL CONTROL JOINTS MUST BE STRAIGHT WITHIN ± 1/4" PER 50'-0", AND PARALLEL TO THE BUILDING WALLS AND PARALLEL / PERPENDICULAR TO EACH OTHER. SLAB CONTROL JOINTS EQUALLY SPACED AS SHOWN ON PLAN. MAXIMUM SPACING NO GREATER THAN 10'-0" AND LENGTH TO WIDTH ASPECT RATIO NO GREATER THAN 1.5. 6. 4" FIBER -REINFORCED CONCRETE SLAB ON GRADE OVER 10 MIL VAPOR BARRIER. 7. 6" FIBER -REINFORCED CONCRETE SLAB ON GRADE OVER 10 MIL VAPOR BARRIER. 8. WATERPROOF BASE PLATES, ANCHOR BOLTS AND COLUMNS WITH ASPHALTIC MASTIC FROM BELOW FINISHED FLOOR ELEVATION TO V ABOVE FINISHED FLOOR ELEVATION. 9. (2) #4 X 4'-0" LONG DIAGONAL REBAR IN SLAB, TYPICAL. 10. SEE SHEET S6.0 FOR FOUNDATION AND SLAB TYPICAL DETAIL REQUIREMENTS. 11. SEE SHEET S7.0 FOR BASE PLATE DETAILS. 12. COLD -FORMED FRAMING: SEE TYPICAL DETAILS AND SECTIONS FOR ADDITIONAL REQUIREMENTS. DRAWING SYMBOLS 1�A # - STEP IN SLAB. NUMBER (IF GIVEN) IS STEP HEIGHT. DENOTES CMU BASE COLUMN SIZE HSS 8x8x1/2 F99 P 9 BP� COLUMN / FOOTING / 1 PEDESTAL/ FOOTING BASE PLATE BASE PLATE TAG MARK PEDESTAL MARK SHEARWALL NOTES AND SYMBOLS - SHEARWALL SEGMENT. - SHEARWALL ► - DOUBLE STUD AND ANCHOR LOCATION. HEARWALL NOTES: NO SUBSTITUTIONS PERMITTED WITHOUT ENGINEERS APPROVAL. SHEATHING APPLIED TO EXTERIOR OF WALL EXCEPT WHERE NOTED OTHERWISI SHEARWLLS FASTENED AND ASSEMBLED PER DETAIL. FOUNDATION SCHEDULE MARK WIDTH LENGTH THICKNESS BOTTOM REINF. EL. AT BOTTOM COMMENTS F30 X - 0" 3'- 0" 1' - 0' (3) #5 E.W. 4-0' F40 4' - 0" 4'- 0" 1' - 0' (5) #5 E.W. 4-0' F50 5'-0' 5'- 0" 1' - 0' (7) #5 E.W. 4-0' F60 6'-0' 6'- 0" 1' - 0' (6) #7 E.W. 4-0' F76 7'-6- 7'- 6" 1' - 0' (8) #7 E.W. 4-0' F8OX50 5'- 0" 8' - 0" 1' - 0" (7) #5 E.W. 4-0' WF24 2'-0' CONT 1' - 0" (3) #5 CONT. -3' - 0' CONCRETE PEDESTAL SCHEDULE MARK TYPE DEPTH VERTICAL REINFORCEMENT TIES P1 18x18 l'-4" (8)#5 #3@6'O.C. 2 19x32 2'-4" (12)#5 #3@6'O.C. P3 48 04 2' - 4" (22) #5 #3 @ 6" O.C. NOTES: 1. SEE SHEET S6.0 FOR PEDESTAL DETAILS. 2. VERIFY FINAL LOCATIONS AND DIMENSIONS OF P2 AND P3 PEDESTALS WITH ARCHITECTURAL PLANS. Vr V� w Y d w 0 O c0 � o d z m w Q < U 3� N CV O Q � Q > W J > mcow� w Of O 0 of ems= Z U C) O N 0 0 N a _O 0 Z J O w LL w U) NLTN o;�oFLr WII`LIAM S I JATHERS y d 3 (1 N N 0 N � N � u tq c C O +• .N N W C!Z w a d z O N Z r W N N W Q N N o O Z L G Ed YU yj a o o U S2.0 FRAMING GENERAL NOTES E F_ in 2"6 n36 n53 n 9" T (9) JST. (EQ. SPACING) (6) JST. (EQ. SPACING) I 5 I COLD FORMED WALL S5.0 FRAMING BELOW, TYP 10" ROOF LADDER, +1 2" W12 19 5' SEE ARCH DWGS � ( ) 1' - 0' - - 2y_6"+ - 15 12 - TYP N W8l(24 (+9' 8') - 17 2 - - 27-6"+ N - -_ S7.0 S7.2 x o S7.0 S5.0 23k W18 40 1k 15k W18X40 16k 16k W14 2 15k + gk W24X55 34k +15' 2" +16-2" +15'-2" +l6-2" - C6X8.2 N C6X8.2 W g z ^ � z o v I C7 °� CONTINUOUS JOIST BRIDGING PER SJI REQUIREMENTS N fy tvJ 0 (1)w r_n -v r_n cn cn cn cn w cn cn r_n r_n _ N J J J J J J J J J J J J J J J M EF-2 M 1 S7.1 T-7718"RO 1' -7118" 100# INSIDE - - - - - - - --C6X8.2- 7' - 9 3l8" INSIDE L - o m METAL ROOFOE K ? ? PROVIDE (4) "STD" 9" o ALUMINUM FRAME 1 1 RO TU-2 o b `� ' C6X8.2 STANDS BY PRECISION S5.0 N 500# 4 3 ALUM. PRODUCTS S5.0 1 (STAND HGT =18") S7.1 S7.3 TYP" S7.3 L6X4X318, 16 TYP WALL CL S7 0 CONTINUOUS JOIST BRIDGING PER SJI REQUIREMENTS ATTACHI 13 S7.2 16' - 0 7/8" INSIDE T -7718" RO ' -4114" RO 1' - 8 301 S7.2 1 NSIDE o S7.1 L6X4X318, w TYP m m N N N N J O O z 0 z g RTU-3i zd o 0 0 o z a N 1500#' 500# S7.1 1000# 11' - 8" 1 cx> � � EXTENT OF FRAME S7.3 � METAL 11' - 0" 0' - 0 7l8" INSIDE LYP X318, cROOF DECK of w o z , LL o z CONTINUOUS JOIST BRIDGING PER SJI REQUIREMENTS ;R ;, I ffi Em w - v v I 11 1/2' o L6X4X3I8 1 RO 19' - 7 3l8"INSIDE LLV, TYP S7.1 mt o � I - Z /M O��y�rQ+�Q o 1' - 0" o o 16 a - EF 1 1.�9+q�Xi m� z z 00 00 !!� 'Op ?>s>. S7.2 in z LOU �" ff) ? p 100# 4? sr V O �55 min oz oz Go oz �� in �� Up omw z min oz 6 mw Lu S7.0 mw mw 44 9N 13K C6X8.2 mOw 7N 1 K 36 3 mw 42k (+16'-31/8") 56k 38k 9' 7 16 19 S7.0 I CROSS BRIDGING 14 S7.0 REQUIRED AT BRIDGING S7.0 2 -1314" 14 INTERUPTIONS (TYP.) - S7.1 - - - - - - - - - - - - - - - - - - 7� - - 1 Y Y I Y Y Y Yam. Y Y Y Y Y Y S7 0 N N C6X8.2 1 C6X8.2 12 S7. I C6X8.2C6X8.2 LW5 S7.4 I cm I ABOVE BEAM (C=1/2') 12 11k ABOVE BEAM W18X 12k �- -- B 11 1 1 18 1 $ zS .0 PRE-ENI IEERED MTL TRUSSES S7. + 1 1 S7.0 `+ S .2 PRE-ENGINEERED MTL TRUSSES S .0 0 � Z X 4o w 5 @24"OC 15 @24'OC 5 Lu = x PLYWOOD 10 j S7.0 �_ PLYWOOD S a LLo X Q x +� O S .0 _ .0 O S7.0 0 -- x rr OF SHEATING ROOF SHEATING I I _ _ _ W8X24-(+17-0") 1 1 9 HSS12X8X5116 (+11'-0") W12X26 (+16'-6") - - - - - - - HSS12X8X5116 (+11'-0") 3 4 6 2 10 3 S7.0 S5.0 FOR CATWALK S5.0 S5.0 SEE ARCH DWGS S5.0 S7 2 S7 0 I I I I U1. IP u1ENT, TYP. 1 S7.2 1. BEAM CONNECTIONS ARE TO BE DESIGNED BY DELEGATED ENGINEER. SUBMITTALS TO BE PROVIDED AS COVERED IN THE SPECIFICATIONS ON SHEET S1.0. 2. SEE SHEET S1.0 FOR DESIGN CRITERIA AND SPECIFICATIONS. 3. REACTIONS SHOWN ON BEAMS ARE _RFD BASED ON THE WORST CASE LOADING COMBINATION PER ASCE 7. 4. USE 10-KIPS AS THE MINIMUM DESIGN LOADING FOR MEMBERS WHERE NO REACTION HAS BEEN SHOWN. 5. USE BOLTED CONNECTIONS FOR W SHAPES TO HSS COLUMNS. WELD HSS MEMBERS TO HSS MEMBERS - BLIND BOLTED I BOLTED CONNECTIONS CAN BE USED WITH APPROVAL FROM ENGINEER. SEE TYPICAL DETAILS REFERENCED IN DRAWINGS. 6. NOTE TO JOIST MANUFACTURER: PROVIDE STANDARD BRIDGING COMPLYING WITH THE APPLICABLE STEEL JOIST INSTITUTE SPECIFICATIONS TYPICAL FOR GRAVITY AND UPLIFT LOADS SUPERIMPOSED ON ALL JOISTS. DIAGONAL BRIDGING SHALL BE PROVIDED BETWEEN ADJACENT JOISTS WHENEVER BOTTOM CHORD HORIZONTAL BRIDGING IS DISCONTINUOUS. 7. DESIGN JOIST FOR AN ADDITIONAL CONCENTRATED LOAD APPLIED TO THE TOP CHORD WHERE SHOWN ON THE ROOF FRAMING PLAN. LOADS SHOWN ARE BASED UPON EQUIPMENT SPECIFIED AT THE TIME OF DESIGN, VERIFY THAT EQUIPMENT LOCATIONS AND UNIT WEIGHTS HAVE NOT BEEN MODIFIED. 8. REFER TO DESIGN CRITERIA ON SHEET S1.0 FOR JOIST LOADING. 9. (�) SLOPE INDICATES GENERAL DIRECTION OF STEEUDECK AND SHEATHING SLOPE. COORDINATE PITCH WITH ELEVATIONS ON PLAN AND ARCHITECTURAL DRAWINGS. 10. METAL DECK SHALL HAVE A MINIMUM OF 3 SPANS. 11. PROVIDE ADDITIONAL SUPPORT AROUND DRAINS, SEE TYPICAL DETAILS ON DRAWING S7.1. COORDINATE LOCATIONS WITH ARCHITECTURAL AND PLUMBING DRAWINGS. 12. COORDINATE AND VERIFY ALL SECTIONS AND DIMENSIONS WITH ARCHITECTURAL DRAWINGS. 13. FINALIZE THE LOCATION OF HVAC UNITS AND ROOF OPENINGS WITH MECHANICAL AND PLUMBING PLANS. METAL ROOF DECK 1. 1.5B20 METAL ROOF DECK, (Fy = 80 ksi) 2. FASTEN USING (7) 518" PUDDLE WELDS AT EA SUPPORT PER 36" WIDTH (36/7), (8) #10 TEK SCREWS AT MID -SPAN OF SIDELAPS AND 5l8" PUDDLE WELDS @ 6" OC ALONG EDGES PLYWOOD ROOF SHEATHING 1. 5l8" WOOD ROOF SHEATING. 2. PLYWOOD FASTENED TO LIGHT GAUGE METAL USING #10 SCREWS (FLATHEAD). FASTEN SHEATHING TO WOOD FRAMING USING 10d TRUSS NAILS OR 8d RING SHANKS, SPACE FASTENERS @ 4" OC EDGE SPACING AND 6" OC FIELD SPACING. ROOF DECK CLOSURE ANGLE 1. CONT L4X4X3/8' UNO 2. DECK CLOSURE ANGLE SHOULD BE CONTINUOUS ALONG THE LENGTH OF THE BUILDING WORST CASE JOIST REACTION MECH UNIT MAX VERTICAL REACTION FROM EQUIP SUPPORT FRAME ON JOIST TOP CHORD EF-1 / EF-2 100 LB RTU-1 750 LB RTU-2 750 LB RTU-3 750 LB REMOTE REFRIG 1350 LB 3 PRE-ENGINEERED METAL TRUSSES BY OTHERS. REFER TO DESIGN REQUIREMENTS SHEET S1 ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTOR WITH EQUIPMENT SUPPLIER PRIOR TO FABRICATION OF STEEL. DIMENSIONS PROVIDED ARE BASED ON COOK GRAVITY VENTS AND LENNOX RTU'S 13 14 S7.0 S7.0 BRACE W 2X26 I BRACE � G SLOPE PLYWOOD w O SLOPE I B - - w U w U Ca -- x `xx' 5l8" WOOD ROOF SHEATHING a O 12X26 NOTE: SLOPE INDICATES GENERAL DIRECTION OF PLYWOOD DECK SLOPE, COORDINATE PITCH WITH ELEVATIONS ON PLAN AND ARCHITECTURAL DRAWINGS. 1 S7.2 z SOL ROOF UNIFORM GRAVITY LOADS SDL GRID I I I I EQUIVALENT LOADING AS ABOVE FOR PERPENDICULAR TO JOIST DIRECTION - DESIGN END JOIST FOR 30K (FACTORED WIND) TOP CHORD AXIAL LOAD. AXIAL LOAD IS NOT TRANSFERRED THROUGH JOIST SEAT NOTE: SNOW DRIFT LOADS OCCUR ADJACENT TO TOWER, PARAPETS, AND ADJACENT TO ROOF TOP MECHANICAL EQUIPMENT. P1 _ P2 PARAPET LOADS P2_ EQUIP. EQUIP. P1: DL=180PUP SL = SEE DIAG. + 150 PLF WL=503PLF+1- P2: DL=30PLF SL = SEE DIAG. + 150 PLF WL=503PLF+1- P1 EQUIP.: REF. WORST CASE JOIST REACTION TABLE FOR LOADING JOIST LOADING DIAGRAM LL 0 0 z w Y d w O c0 2ii o Q ~ d z m Q w U N CV O Q � Q > w J C5 W [z Lo cOfl Of O Lu 0of z Q w °d _ U O N �% 0 N Ix0 a J Cz G LL uj 0 0N H I. V w w x UO WI IAMJ MATHERS a m 3 O N N 0 N rn N u tq c c g O +" 'y N W Lu w a d z N z Z N N LL G LL Y W O O Z Q ui .4� 02 co a o c ci FRAMING PLAN 3116" = V-0" TOWER FRAMING PLAN 3116" =1'-0" S3.0 SHEET GENERAL NOTES 1. SEE GENERAL NOTES AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS NOT SHOWN HERE TO INCLUDE PAINTING I COATING REQUIREMENTS. 2. FIELD ADJUST LOCATION OF CONT CHANNELS AS REQUIRED TO BEAR AT LOW POINTS OF ROOF DECK 1 1.1 3 4 5 6.1 7 24'-0' W12X26 W12X26 I I I I I I I II W24X55 (C=112') W18X40 16'-0" JIII I I I II I I I I I u� X x X :n uxi X ^xn X ^xn 2 I = I = I = I I I I I I I I I I I I _2N-0n 3 GRIDLINE D & D.1 ELEVATION B C D D1 E F I I I I I I I I I I II L I Ct Ct 2'-6"*— C6X8.2 1 0" 2 6'+ C678.2 32LHSP 12K1 16'6" 1V-2' I I I I I HSS12X4X5116 (GALVANIZED) x xl Ix x, x co fn x co co to =I to xN I = IxZ = CQ< II I -0i$n _2N-0n r-0^ OL 2 GRIDLINE 1 ELEVATION 7 5.3 3.6 2.6 1 I I I I I I I I I I I I I I W24X55 W14X22 W18X40 W18X40 15'-2' I I I I I I I I I I I I <o co <o co m x x X x x x x x x x x x co co co N N x �x ix �x x I I I I I I I I 0' pn ri Jill �1 GRIDLINE B ELEVATION Sa.O 3116" =1'-01. Lu Y d W O coo Q�� z�m< wQCD U N N Q Q W J m cLlul W COO ofO Lu of Z w U 0 cn O N �% a op WILD MATHERS y m 3 10 o� " 0 " N � U fn C C O +• .N N W C!Z W a d z O N Z N N LL G LL U �`+ �o LLI W O O Z � Y Q LLI 0 N O q _ N Q ILD a o ci S4.0 FRONT TOWER FRAMING SECTION 112" =1'-0" SEE PLAN 6" MTL STUD WALL BRIDGING WHERE SHOWN & 4'-0" OC VERT SPACING 6" MTL STUD WALL BRIDGING WHERE SHOWN & 4'-0" OC VERT SPACING 12 1 S7.1 SIM oII S71 BOTTOM FLANGE BEAM BRACE TO BOTTOM CHORD OF JOIST g L BOTTOM FLANGE BEAM BRACE TO BOTTOM 15 I S7.1 CHORD OF JOIST S7.2 / 6" MTL STUD IL ------ STOREFRONT, SEE ARCH. � FRONT WALL SECTION WITH WINDOWS S5.0 318" = 1'-0" 11 S7.2 S Nk� livillm im-NON. BOTTOM FLANGE BEAM BRACE TO BOTTOM CHORD OF JOIST 6" MTL STUD WALL BRIDGING WHERE SHOWN & 4'-0" OC VERT SPACING 6" MTL STUD WALL BRIDGING WHERE SHOWN & 4'-0" OC VERT SPACING S6.0 �2 BACK WALL SECTION S5.0 318" =1'-0" S7.1 jII I \— SEE ROOF A I PLAN FOR JOIST \ — 6" MTL STUD WALL BRIDGING WHERE SHOWN & 4'-0" OC VERT SPACING SHEET GENERAL NOTES 1. SEE GENERAL NOTES AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS NOT SHOWN HERE TO INCLUDE PAINTING I COATING REQUIREMENTS. 2. DETAILS FOR CONNECTIONS ARE SCHEMATIC. STEEL FABRICATOR SHALL PROVIDE FINAL CONNECTION DESIGN. LIGHT GAUGE METAL SUPPLIER SHALL ADOPT REQUIRED COMPONENTS AS SHOWN IN THE DETAILS AND ADJUST TO SPECIFIC FIELD CONDITIONS. EXTERIOR COLD FORM FRAMING NOTES ITEM NOTES COMMENTS 6" WALL STUDS 600S162-54MIL(16GA)(50KSI) PUNCHED ALL EXTERIOR STUD SPACED @ 16" OC MAX WALLS 6" CONT TOP TRACK CONT 600T125-54MIL(16GA)(50KSI) WI (2) #10 SCREWS TO EA STUD 6" CONT BOT TRACK CONT 600T125-54MIL(16GA)(50KSI) WI (2) #10 @ ROOF DECK SCREWS TO EA STUD & (2) #10 SCREWS TO ROOF DECK @ 12" OC & AT EA END OF TRACK 6" CONT BOT TRACK CONT 600T125-54MIL(16GA)(50KSI) WI (2) 0.157" @ STL CHANNELS DIA PAF TO STL CHANNEL @ 12" OC & AT EA END OF TRACK 6" CONT BOT TRACK SIMPSON TITEN HD 518" DIA X 6" ANCHORS TO FOUNDATION SPACED @ 16" OC & WITHIN 8" OF WALL ENDS CONT BRIDGING CONT COLD ROLLED (U-CHANNEL) & SIMPSON 4'-0" OC VERT SPACING & 12" STRONG -TIE SUBH3.25 WI (1) #10 SCREW TO FROM EA END OF STUD CONT CHANNEL COLD FORM CONNECTOR NOTES FASTENER TYPE FASTENER INFORMATION APPLICATION COMMENTS PAF GALVANIZED - 0.157" DIA EXTERIOR APPLICATIONS SIMPSON PDPA OR POWDER ACTUATED FASTENER HILTI X-U PAF PAF 0.157" DIA POWDER ACTUATED INTERIOR APPLICATIONS SIMPSON PDPA OR FASTENER HILTI X-U PAF #10 SCREW #10 SELF -DRILLING SCREW COLD FORM STEEL TO 16 THREADS PER INCH, METAL DECK #1 DRILL POINT #10 SCREW #10 SELF -DRILLING SCREW COLD FORM STEEL TO 16 THREADS PER INCH, COLD FORM STEEL (18GA #3 DRILL POINT OR THICKER) #10 SCREW #10 SELF -DRILLING SCREW COLD FORM STEEL TO 24 THREADS PER INCH, STRUCTURAL STEEL #3 DRILL POINT #12 SCREW #12 SELF -DRILLING SCREW COLD FORM STEEL TO 14 THREADS PER INCH, COLD FORM STEEL (18GA #3 DRILL POINT OR THICKER) #12 SCREW #12 SELF -DRILLING SCREW COLD FORM STEEL TO 14 THREADS PER INCH, STRUCTURAL STEEL #5 DRILL POINT #14 SHOULDERED SIMPSON XLSH78B1414 COLD FORM STEEL JAMB TO SCREW SHOULDERED SCREW HEAD OF WALL CONNECTION NOTES: 1. SEE SHEET S1.0 FOR APPROVED FASTENERS 2. GALVANIZED FASTENERS REQUIRED AT ALL EXTERIOR CONNECTIONS 3. CONSULT MANUFACTURER PRODUCT DATA FOR DRILL POINT REQUIRED FOR BASE MATERIAL: w Y d w O coo � o Q ~ rn d z m Q w < U N CV O Q � Q > OfJ W _ � m�w� Lu OfO Lu (� z ¢ IT _ U O N 0 o N Ix cl a z O U Lu fU) CV LL G I..f_ 0 Lu O 0 LLI J p U w w x O���ALTH Op Lt WIJILIAM S MATHERS a N 3 O N N 0 rn N c c g O +• 'C H N W C � w a d 2 O N Z N N LL G LL YLu W O O Z Q 0 N O q _ N Q a o c ci 5 REAR TOWER FRAMING SECTION 55.0 112" =1'-0" 3 FRONT WALL SECTION S5.0 318" = V-0" �1 SIDE WALL SECTION S5.0 318" =1'-0" S5.0 SHEET GENERAL NOTES MASONRY JOINT REINF MASONRY JOINT REINF REINFORCEMENT (4 TOTAL) REINFORCEMENT (3 TOTAL) SEE 1. SEE GENERAL NOTES AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS NOT SHOWN SEE SCHED PLAN A HERE. 2" • ° • 2. ALL CONTINUOUS REINFORCEMENT SHALL BE LAP SPLICED AT CORNERS USING "L" BARS. SLAB CONTROL JT N • • • COL AND BP PER PLANS ' PRE -FABRICATED "T" FOR a • AND SCHED <iQ1 WIRE REINFORCEMENT #5 REBAR (12 TOTAL) 2" COVER 6" F'OR w FORMED CORNERS x • r ____I w 1 1 AT INTERSECTIONS- - AT CORNERS - CD SEE 1_ - — — PLAN FILL WITH CONIC � --� CENTER REINFORCEMENT IN MASONRY • • • CELL -LINO s 1 112" EXPANSIVE JOINT -FILLER a STRIPS � (2) #3 TIES. PROVIDE (1) #3 SLAB -ON -GRADE TIE WITHIN 6" OF TOP OF (TYPICAL) PEDESTAL FILL CMU SOLID MASONRY JOINT REINFORCEMENT WI GROUT NOTE: ADJUST DETAIL AS NEEDED TO ACCOMMODATE FIELD - AT TYPICAL WALL - CONDITIONS NOTE: SEE TYPICAL WALL SECTIONS FOR REINF SIZE AND SPACING REQUIREMENTS. 15 P2 PEDESTAL SECTION 11 TYPICAL ISOLATION JOINT DETAIL 7 TYPICAL CMU DETAILS Ss.O 314" =1'-0" S6.0 1" =1'•0" S6.0 1 112" =1'-0" OVER POUR ALL BP SEE PLAN FOR STL COL 11 11 12 13 3 2" 6" MTL STUD SEE PLAN FOR BP, 10" MIN ANCH EMBED S6.0 S T&B CONT (LO CONC PEDESTAL SHRINK NON -GROUT 1l2" EXPANSIVE JOINT -FILLER STRIP REINF, SEE PLANS 600T125-54 TRACK 4"THICK CONIC SLAB -ON -GRADE WALL FTG 1 1l2" WALL FTG N 4" SLAB THICKNESS 6" SLAB THICKNESS #10 SELF -DRILLING SCREW SCREWS AT EA STUD TO TRACK 1ST POUR 2ND POUR 4" THICK CONC SAW CUT JOINT 6" THICK CONIC cC o ° ° Gp #5 REBAR SLAB -ON -GRADE (C.J.) SLAB -ON -GRADE N (8 TOTAL) 1l2" SIMPSON TITEN HD WI (5 3l4") o w a - • ° ° EMBED ANCH @ 16" OC & WITHIN 8" OF (3) STIRRUPS WITHIN 15 = o a - d. WALL OPENINGS I ENDINGS 5" OF TOP OF PEDESTAL $6.D w a F VERIFY ALL REQUIRED FLASHING " - REINFORCEMENT a' Lu SEE PLAN FOR vwi ° VAPOR BARRIER & WEATHERPROOFING HAS BEEN INSTALLED PER ARCH PLANS, SEE SCHED �, w „� a• '- .• e PEDESTAL KEYWAY CENTERED IN FTG THICKNESS LAP SPLICE _ #3 TIES @ 6" OC PROVIDE DETAILS, & SPECIFICATIONS. a x ; '. ° ' -, ;, •' ° 48 BAR DIA (3) #3 TIES WITHIN 6" OF :. ',; EXTEND BAR FROM 1ST TOP OF PEDESTAL 6" CMU COURSE CONIC SLAB ON GRADE w a w ° POUR TO ACCOMODATE °, LAP SPLICE SEE SCHED °3"' ° ° NOTE: NO PUNCH HOLES WITHIN 12' OF END OF STUD SEE SCHED SEE SCHED TYPICAL COLD -FORMED WALL' BASE 1g TYPICAL WALL FTG CONSTRUCTION JOINT 14 S6.0 P1 PEDESTAL SECTION 1 112" =1'-0" 1p SLAB TRANSITIONS 6 CONNECTION 3 COLUMN FOOTING WITH PEDESTAL 56.0 1 ^ =1'-0" Ss.O 1" =1'-0" S6.0 1 112" =1'-0" S6.0 314" =1'-0" SEE PLAN BEND TOP DOWEL INTO #5 Wl STANDARD 90-DEG. HOOK BEND TOP DOWEL INTO #5 WI STANDARD 90-DEG HOOK SLAB AS SHOWN @ 32" OC (EXTEND INTO CMU) SLAB AS SHOWN @ 32" OC (EXTEND INTO CMU). CTR REINF IN MASONRY CELL LINO CTR REINF IN MASONRY CELL LINO 8" THICK CONC 8" THICK CONIC SLAB -ON -GRADE SLAB -ON -GRADE `� SEE PLAN e - m a• e m a e= 1l2" EXPANSIVE JOINT- a.. P p °` FILLER STRIPS ° • ® 9 d • -, ' 4 ' STRUCTURAL COL. AND FILL WITH CONC 4 . a` a BP SEE PLANS 4" THICK CONC FREEZER, SEE 1.5" THICK HIGH STRENGTH SLAB -ON -GRADE . . CONTROL JOINT r — — — fi — — — WATERPROOF BP, AB, I AND COL WI ASPHALTIC 1" ARCH I MECH NON -SHRINK GROUT (SEE SLAB -ON -GRADE DETAIL) w #5 REBAR, CONT #5 REBAR (CONTINUOUS) MASTIC FROM BELOW FF x 1l2" EXPANSIVE #5 DOWEL WI STANDARD 90-DEG ELEV TO 1" ABOVE FF _ a- " - i Ln Lu JOINT -FILLER STRIPS TOP OF SLAB 8" CMU GROUTED #5 DOWEL WI STANDARD 90-DEG. HOOK @ 32" OC (EXTEND INTO CONIC). 4" CMU GROUTED SOLID HOOK @ 32" OC (EXTEND INTO CONC). CTR REINF IN MASONRY CELL LINO PAN — — — — 1 — ELEV— N 1 SOLID CTR REINF IN MASONRY CELL LINO 4 4 ° 8" CMU GROUTED SOLID aa. FILL WITH CONIC L — — J1 #5 REBAR 8" MIN VAPOR BARRIER Lu w a. ^ ' ' ., ° aP (CONT AT STEP) SEE SCHED x J U c.> SEE SCHED - S SC STRUCTURAL RAL PEDESTAL, S UC U S (n 8 n w �— " rn ° w - ' " - - SEE PLANSLu vwi - -i. ' . ° •�- .. �_ cl),- ° a`.; e 3' SEE PLAN FOR BP SEE FTG SCHED TYPICAL SLAB ON GRADE EDGE OF SLAB 2 c.) (10" MIN ANCH EMBED � SEE SCHED SEE SCHED w SEESCHED Lu 17 SLAB EDGE AT ROLL UP DOOR 13 ISOLATION JOINT AT WALL �g SLAB STEP �� TYPICAL INTERIOR COLUMN PAD 2 SLAB EDGE STOREFRONT AND DOORWAYS Ss.O 1" =1'-0" S6.0 1" =1'-0" Ss.O 1" =1'-0" S6.0 112" =1'-0" S6.0 1" =1'-0" 6" MTL STUD 6 SEE SCHED 2" (:#) GALV STL COL AND BP SEE PLAN S6.0 CONTROL JOINT TO BE COATED WITH 5" WIDE X 8" DEEP OVAL CUT #3 REBAR. CMU GROUTED 6" CMU N STRUCTURAL COL AND BP WATERPROOF BP, AB, AND COL WI ASPHALTIC MASTIC (C.J.) CARBOLINE COATING IN COL FACE TO FACILITATE FOR A DUPLEX SYSTEM SOLID WI CONT BAR. - TERMINATE BAR AT STL COL 1l2" EXPANSIVE JOINT -FILLER STRIPS • • • • • SEE PLANS — FROM BELOW r — — — 7 — FF ELEV TO 1" ABOVE FF ELEV 4" OR 6" THICK CONIC OPENIINNG LOCATION WI ARCH USE "L" BARS AT CORNERS 2" COVER SLAB -ON -GRADE, SEE PLAN FILL WITH CONIC DWGS • #5 REBAR (22 TOTAL) • SEE 1 1l2" THICK HIGH STRENGTH TOP OF SLAB NON -SHRINK GROUT °. w 2 0 N • • 4"THICK CONC SLAB -ON- 8" X 8" CONIC TIE BM EPDXY 5" STRUCTURAL PEDESTAL, 1l2" EXPANSIVE JOINT -FILLER STRIPSGRADE (SEE ON DOWEL OR CONTINUE SEE PLANS -III— - GRADE DETAIL�B REINFORCEMENT THROUGH • • - 1l2" EXPANSIVE o CONC PEDESTALS 8" THICK CONCSLAB-ON-GRADEFILL WITH CONC4� 6"THICK LAYER OF COMPACTED VAPOR BARRIER JOINT -FILLER STRIPS = STONE CRUSHED SO SEE PLAN FOR BP U (GALV) 8" CMU GROUT SOLID ( ) #5 DOWEL WI STANDARD 90 DEG. HOOK @ 32" OC (EXTEND INTO 6" • • • • • _ i ° _ .. .. CMU) CENTER REINF IN MASONRY w s .--are <a. CELL - LINO (2) #3 TIES. PROVIDE (1) #3 TIE WITHIN 6" OF TOP OF EDGE OF SLAB SLAB ON GRADE TYP. NOTES: 1. CONTROL JOINT SHALL BE A MIN OF 1l4" WIDE AND ONE FOURTH THE SLAB DEPTH. SEE PLAN FOR BP, 3" c� °. •' co w ° ',�- ' SEE PLAN & FTG SCHED FOR SIZE, DEPTH &REINF READ IN FTGS PEDESTAL 2. JTS SHOULD BE SAWED AS SOON AS THE CONIC IS HARD ENOUGH THAT THE SAWING DOES 10" MIN ANCH EMBED SEE SCHED NOT RAVEL JOINT EDGES OR DISLODGE COARSE AGGREGATE PARTICLES. 3. CURE SLAB PER SPECIFICATION REQUIREMENTS. SEE SCHED 16 P3 PEDESTAL SECTION 12 ISOLATION JOINT CORNER g TYPICAL SLAB / CONTROL JOINT DETAIL 4 TYPICAL EXTERIOR CANOPY COLUMN PAD 1 TYPICAL WALL AND FOOTING SECTION Ss.O 1" =1'-0" 56.0 1" =1'-0" Ss.O 1" =1'-0" S6.0 112" =1'-0" S6.0 1" =1'-0" w Y_ d w O coo � o d z � m U N CV O Q � J Q > Of w J > m LL co w � co Of O Lu 0 Of z ¢ IT _ U O N U 0 cn a U) J Q H Lu 0 m Q J U) Q 0 J OH W LL w x U) Gf S MATHERS y �sSIONAL m 3 N N 0 N N � u tq c c g O +• 'y N W H w a d 2 O N Z N H N LL LL LLQ Y W o Z Q 0 N O Q (7 W (n Q a o G c=i S6.0 TYP uV V V AS REQD NOTE: 1. CONTINUITY CONNECTION REQUIRED ACROSS ALIGNING TRUSSES FOR SEISMIC CATEGORY "C" BUILDINGS. USE L2X2X3/16" - V-0" LONG CENTERED AND WELDED W/ 1/4" FILLET WELDS EACH SIDE - 4" LENGTH. JOIST TO GIRDER CONNECTION 314" =1'-0" CONT DECK CLOSURE ANGLE, SEE ROOF PLAN 3/16 V 2-12 CONT CHANNEL TYP AT EA 3116 2" JST TYP AT MTL ROOF DECK, EA JST 3116 2 SEE ROOF PLAN L4X4X3/8" (CUT TO FIT BETWEEN JST. INSTALL AS SHOWN - LEG UP FLUSH WI FLANGE) 3/16 2-12 JST TO B 3116 2' CONNECTI N BM PER PLANS L1 112X1 112X3/16" LOCATED JST PER PLAN AT EA JST ALONG GRIDLINE D P =1.5 K+I- ULTIMATE 1g JOIST TO BEAM CONNECTION - FRONT 3/4" = l'-0" CONT DECK CLOSURE ANGLE. SEE ROOF PLAN (INSTALL LEG DOWN AS SHOWN) BM, SEE PLANS TYP AT 3/ 4114 2• EAJST JST TO BM 2 CONNECTION MTL ROOF DECK, SEE ROOF PLAN L1 1/2X1 1/2X3116 LOCATED AT - EA JST ALONG GRIDLINE B P =1.5 K d- ULTIMATE 17 JOIST TO BEAM CONNECTION - REAR JOIST CENTERLINE SEE PLAN 9" TYP WALL FRAMING, SEE SECTIONS EOD = 6" MAX. I I METAL DECK, SEE PLAN I JOIST, SEE PLAN I EDGE OF DECK DETAIL TYP DETAIL AT GRID B 3" TYP EDGE OF DECK EDGE OF DECK DETAIL 1" =1'-0" COL, SEE PLAN I I z -v TYP DETAIL AT GRID D NTERLINE BM WEB - SEE PLAN FOR SIZE, TYP l �00° / ECK - PL 3/8" THICK 5116 - L3l/2X31/2X1/4 (2) 3l4" DIAA325-N BOLTS 5/16 NOTE: 1. INSTALL BRACES 3" - 4" BELOW TOP OF BM BOLT PROJECTIONS MUST REMAIN BELOW T.O.S. 14� TOWER BRACE CONNECTION (HORIZONT, S7.0 / 131 TOWER BRACE CONNECTION (VERTICAL S7.0 / 3/4" =1'-0" PL 1/4" THICK WIDE FLANGE, SEE PLANS (CAP PLATE) I 1 3/16 � I 3/16 7o I 11/2"- `� PL 3/8" THICK, BOTH 1 SIDES OF COL 3/16 12 3/4" DIA THROUGH BOLT 3/16 12 I COL, SEE PLAN III NOTES: 1. USE 3/4" DIA BOLTS. 2. ALL BOLT HOLES 13/16" DIA. 12 HSS 4X4 COLUMN TO W BEAM T SINGLE PLATE SHEAR CONNECTION TO BEAM OR COLUMN BEAM SIZE NUMBER OF 3/4" DIA. A325-N BOLTS PLATE THICKNESS PLATE LENGTH WELD SIZE W8, W10 2 5/16" 5-1/2" 3/16" W12, W14 3 5/16" 8-1/2" 1/4' W16 4 5/16" 11-1/2" 1/4" W18 5 5/16" 14-1/2" 1/4" W21 6 5/16" 17-1/2' 1/4" W24, W27 7 3/8" 20-1/2" 114" NOTES: 1. MINIMUM THICKNESS OF SUPPORTING MEMBER TO BE 0.20". WHEN THE WELDS FROM A SECOND CONNECTION ON THE SUPPORTING MEMBER ARE DIRECTLY OPPOSITE, MINIMUM THICKNESS TO BE 0.39". 2. PROVIDE HORIZONTAL SHORT SLOTTED HOLES IN BEAM WEB ONLY. 11 SINGLE PLATE SHEAR CONNECTION 57.0 314" =1'-0" COL, SEE PLAN 3 SIDES 3116 3/16 V L4X4X3/8 (5" LONG) 3116 BM, SEE PLAN (CAP END W/ 1/4" PLATE NOTSHOWN) 3/16 V L4X4X3/8 INSTALL ANGLE ON COL FACE OPP OF THE BM END 3/16 WT6X13 4" 3/16 HSS COLUMN TO HSS BEAM W/ OFFSET 10 SUPPORT 1 112" =1'-0" PL 1/4" THICK (CAP PLATE) O HSS COL PER PLANS AND SCHED FLUSH TO COLUMN - HSS BM PER PLANS 3 SIDES �AS REQD 5" WIDE X 8" DEEP OVAL CUT IN COL FACE AT EXTERIOR CANOPY. VERIFY COL LOCATIONS WITH ARCH DWGS TYPICAL HSS COLUMN TO HSS BEAM g CONNECTION PL 3/4" THICK N (CAP PLATE) 0 11/2' TYPE n 1/41 / 4" 4 3/4" DIA A325-N BOLT (2 MIN FOR ERECTION ONLY) PL 3/4" THICK (CAP PLATE) r JST GIRDER PER PLANS HSS COL, SEE PLANS AND SCHED PL 3/4" THICK (STABILIZER PLATE) DO NOT WELD COLUMN TO JOIST GIRDER CONNECTION BEAM PL 3/4" 11/2" THICK v o - o 3/4" DIA A325-N BOLT (4 - FOR ERECTION ONLY) ° I`- - J ° PL 3l4" THI K ZT \ r TYP 1l4 4' Lw 41/2" 112" 3116 il4 3/16 I JST GIRDER PI-3/ THICK PER PLANS (STABILIZER PLATE COL, SEE PLANS AND SCHED DO NOT WELD INTERMEDIATE COLUMN TO JOIST GIRDER CONNECTION T-0" 1112" 41/2" 41/2" 11/2" USE 3/4' DIA. ANCHORS 77 0 _ m � N PL 1" THICK 1/4 N TE : 1. COL IS CENTERED ON THE BP. 2. ASTM F844 WASHERS TO BE USED WITH HOLE CLEARANCES LIMITED TO 5/16" FOR ROD DIAMETER UP TO 1". TOLERANCES ARE SMALLER THAN THOSE PERMITTED IN ACI 117. BASE PLATE BP4 11/2" = V-0" BP3A =12" BP3B =14" 1l2" 1 USE 3/4" DIA. ANCHORS 11/2" 11/2" BP3A == PL 1"THICK BP3B = PL 3/4' THICK NOTES: 1. COL IS CENTERED ON THE BP. 2. ASTM F844 WASHERS TO BE USED WITH HOLE CLEARANCES LIMITED TO 5/16" FOR ROD DIAMETER UP TO 1". TOLERANCES ARE SMALLER THAN THOSE PERMITTED IN ACI 117. BASEPLATE BP3 314" =1'-0" S7.0 1 112" =1'-0" LOCATED PER PLAN AND REQ'D AT LAST JST BAY AS REQ'D FOR UPLIFT TYPICAL JOIST BRIDGING 11" USE 3/4" DIA. ANCHORS 1 1/ " 4" N' l/2" N o> N BP2 = PL 3/4" THICK 1/4 INSIDE BUILDING BP2A - PL 1" THICK NOTES: 1. ASTM F844 WASHERS TO BE USED WITH HOLE CLEARANCES LIMITED TO 5116" FOR ROD DIAMETER UP TO 1". TOLERANCES ARE SMALLER THAN THOSE PERMITTED IN ACI 117. BASEPLATE BP2 11/2" = V-0" 11" 11/2" 4" 4" 11/2" N USE 3/4" DIA. ANCHORS v v I I PL1"THICK 1/4 V NOTES: 1. COL IS CENTERED ON THE BP. 2. ASTM F844 WASHERS TO BE USED WITH HOLE CLEARANCES LIMITED TO 5/16" FOR ROD DIAMETER UP TO I". TOLERANCES ARE SMALLER THAN THOSE PERMITTED IN ACI 117. BASEPLATE BP1 w Y d w O coo � o rn w Q z m d Q w U N Q N Q > Ld Q W J E > m co Lu w co Of O Lu 0 Of Z w °� _ U O cn N 0 N Ix o a 00 7MAT G,I�HERS y N 3 M ILO O N N o rn N fn c c g O + N w rn C � w a d z O N Z N H N l L LL LLQ YLu W o Z a 0 N O (7 W (n Q a o o c=i STO 1" =1'-0" 1" =1'-0" 314" =1'-0" 1 112" = V-0" 1 112" =1'-0" STUD FRAMING BEYOND L FASTEN BLOCKING TO SHEATHING FASTEN BLOCKING TO SHEATHING 60OT125-54 BLOCKING SIMPSON SCW5.5 WI (3) #14 SHOULDERED SCREWS @ CLIP I � 1 (4) #12 @ CLIP n L8X6X1/2 1/4I/ 2 @ 6 BLOCKING CONNECTION 60OT125-54 SOLID BLOCKING CONT CONT EDGE ANGLE (2) SIMPSON SCW5.5 W/ (3) #14 SHOULDERED SCREWS, TYP DETAIL 1 112" = V-0" 1/4I/ 2 @ 6 JOIST 6" MTL STUD "T 10T TRACK WALL MUST BE LOCATED CONT DECK CLOSURE ANGLE. OVER SUPPORT OVER TO ROOF PLAN I � c� CONT BRIDGING CONT L2X2-43MIL (18GA) 6" CONT BOTTOM TRACK MTL ROOF DECK, SEE PLAN JST/SUPPORT PER PLANS NOTE: NO PUNCH HOLES EDGES WITHIN 12" OF END OF STUD TOWER COLD -FORMED FRAMING BASE CONNECTION - CHANNEL PERPENDICULAR 7.1 1 1/2" = V-0" WALL MUST BE CENTERED OVER SUPPORT CHANNEL I 6" MTL STUD CONT BRIDGING 2 CONT BOT TRACK CONT CHANNEL 3/16 � �� MTL ROOF DECK, INSTALL SECOND ANGLE SEE PLAN IF REQUIRED TO SUPPORT WALL (IF NOT CENTERED ON BAR JST PER PLAN SUPPORT CHANNEL) REINFORCEMENT REQ'D AT JST WHEN CHANNEL NOT AT PANEL POINT TOWER COLD -FORMED FRAMING BASE 13 CONNECTION 11.011 6" MTL STUD (4) #12 SCREWS 17 STUDS @ 16' OC SIMPSON FCB411.5 FIXED - CLIP CONNECTOR CLIP c c a a aaa o 0 «•. U u u U U O O 16 SIMPSON SC62.5/97 @ STUD W/(3)#14 SHOULDERED SCREWS. FASTEN TO - ANGLE W/(4)#12 A 15 CONNECTION AT SIDES 57.1 1 112" =1' 0" MAX - 6" STUDS @ 16" OC L8X6X112 MTL DECK JOIST 31MPSON SSB3.518 "ONNECTOR EA STUD WI 2) #14 SHOULDERED SCREWS INTO STUD & (2) #12 INTO JOIST tr CONT CHANNEL CONT DECK CLOSURE ANGLE, SEE ROOF PLAN (8) #12 SCREWS EA CLIP - (4) INTO STUD & (4) INTO ANGLE STL BM 1l4 2-12 ' • ' � il4 2-12 SIMPSON FCB411.5 FIXED -CLIP CONNECTOR (SEE TOP CLIP FOR CONT L4X4X3/8 CONNECTION REQUIREMENTS) CONT 6" CAP TRACK 12� COLD -FORMED SPANDREL CONNECTION CONT CHANNEL 6" MTL STUD (4)#12 SCREWS SIMPSON SCB4 SLIDE -CLIP CONNECTOR, AT STUD. COLD -FORMED TOP OF WALL BYPASS CONNECTION T 6" BOT TRACK T DECK CLOSURE ANGLE. ROOF PLAN 12 SCREWS 3M CONT L2X2-43MIL (18GA) INFILL FRAMING AT SUPPORT BEAMS 1 112" =1'-0" 6" MTL STUD W/ (2) PAF @ 16" OC AND WITHIN 8" OF WALL ENDS \STEN USING (1) ROW OF 4ERS @ 24" OC AND WITHIN IEMBER ENDS SCREWS @ 16" OC STL BM, SEE PLAN 6" MTL STUD WALL BRIDGING WHERE SHOWN & 4'-0" OC VERT SPACING COLD -FORMED WALL TO BOTTOM OF STEEL 9� CONNECTION S7.1 1 112" =1'-0" C4X DOF DECK C4X5.4 (2) #10 SCREWS AT RIB NOTE: FOR LARGER OPENINGS SEE JST MECH UNIT SUPPORT DETAIL METAL DECK PENETRATIONS FOR OPENINGS TO 24" PERPENDICULAR TO DECK 314" =1'-0" 6" 1' -0.16" MAX 1.51320 MTL ROOF DECK °II II ° II II II II° III II II II II PUDDLE WELD OR w II II °II II OPEN II II II II #10 SCREWS @ 8" OC MAX II II II II II II II II 0.071" REINF II II II II II II II II pL ,1 o �, ��o NOTE: FOR HOLES 6" DIA OR LESS - NO REINFORCING PLATE IS RED D METAL DECK PENETRATIONS FOR OPENINGS TO 12" PERPENDICULAR TO DECK 57.1 314" =1'-0" DECK TYPES 1.5 (B,F,A,VL) 36/7 PATTERN 36/5 PATTERN 36/4 PATTERN 36/3 PATTERN METAL DECK FASTENING PATTERNS 314" =1'-0" PUDDLE WELDS @ 12" OC MAX TO COLLECTOR ELEMENTS AND EQUIP FRAMING U) O a a U J w w U w O w z 1 w F_ z w U SUPPORT FRAMING FASTEN DECK AT JST PER REQ'D PATTERN 51 METAL DECK FASTENING S7.1 314" =1'-0" TY 5/8" PUDDLE WELDS 6" OC AT EDGE SUPPORTS SIDELAP CONNECTION, #10 TEK SCREWS 1.5B20 MTL ROOF DECK DECK EDGE CHANNEL, SEE PLAN MTL ROOF DECK, SEE PLAN L2.5X2.5XI/4 (AS REQ'D) /v/ T TYP BOTH 3/16 21I2' JST, SEE PLAN ENDS 3/16 21/2' NOTE: WHERE CONCENTRATED LOAD EXCEED 100LBS AND FALLS BETWEEN TOP OR BOTTOM CHORD PANEL POINTS PROVIDE AND INSTALL (2) STRUTS ON EACH SIDE OF JST. JOIST CONCENTRATED LOAD SUPPORT 57.1 314" =1,-0" 3/16 JST TYP 1" MAX 3/16 I 1/2" RADIUS SUPPORT ANGLE JST W/ L.L.V. INTERMEDIATE SUPPORT - JST 3/16 1" MIN. 1" MAX TYP 3116 1/2" RADIUS SUPPORT ANGLE JST WI L.L.V. - END SUPPORT - MECHANICAL SUPPORT ANGLE CONNECTION 3 DETAILS 57.1 1 112" =1'-0" SHEET GENERAL NOTES 1. SEE GENERAL NOTES AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS NOT SHOWN HERE TO INCLUDE PAINTING / COATING REQUIREMENTS. 2. DETAILS FOR CONNECTIONS ARE SCHEMATIC. STEEL FABRICATOR SHALL PROVIDE FINAL CONNECTION DESIGN. LIGHT GAUGE METAL SUPPLIER SHALL ADOPT REQUIRED COMPONENTS AS SHOWN IN THE DETAILS AND ADJUST TO SPECIFIC FIELD CONDITIONS. EXTERIOR COLD FORM FRAMING NOTES ITEM NOTES COMMENTS 6" WALL STUDS 600S162-54MIL(16GA)(50KSI) PUNCHED ALL EXTERIOR STUD SPACED @ 16" OC MAX WALLS 6" CONT TOP TRACK CONT 600T125-54MIL(16GA)(50KSI) WI (2) #10 SCREWS TO EA STUD 6" CONT BOT TRACK CONT 600T125-54MIL(16GA)(50KSI) WI (2) #10 @ ROOF DECK SCREWS TO EA STUD & (2) #10 SCREWS TO ROOF DECK @ 12" OC & AT EA END OF TRACK 6" CONT BOT TRACK CONT 600T125-54MIL(16GA)(50KSI) WI (2) 0.157' @ STL CHANNELS DIA PAF TO STL CHANNEL @ 12" OC & AT EA END OF TRACK 6" CONT BOT TRACK SIMPSON TITEN HD 5/8" DIA X 6" ANCHORS TO FOUNDATION SPACED @ 16" OC & WITHIN 8" OF WALL ENDS CONT BRIDGING CONT COLD ROLLED (U-CHANNEL) & SIMPSON 4'-0' OC VERT SPACING & 12' STRONG -TIE SUBH3.25 W/ (1) #10 SCREW TO FROM EA END OF STUD CONT CHANNEL COLD FORM CONNECTOR NOTES FASTENER TYPE FASTENER INFORMATION APPLICATION COMMENTS PAF GALVANIZED - 0.157" DIA EXTERIOR APPLICATIONS SIMPSON PDPA OR POWDER ACTUATED FASTENER HILTI X-U PAF PAF 0.157"DIA POWDER ACTUATED INTERIOR APPLICATIONS SIMPSON PDPA OR FASTENER HILTI X-U PAF #10 SCREW #10 SELF -DRILLING SCREW COLD FORM STEEL TO 16 THREADS PER INCH, METAL DECK #1 DRILL POINT #10 SCREW #10 SELF -DRILLING SCREW COLD FORM STEEL TO 16 THREADS PER INCH, COLD FORM STEEL (18GA #3 DRILL POINT OR THICKER) #10 SCREW #10 SELF -DRILLING SCREW COLD FORM STEEL TO 24 THREADS PER INCH, STRUCTURAL STEEL #3 DRILL POINT #12 SCREW #12 SELF -DRILLING SCREW COLD FORM STEEL TO 14 THREADS PER INCH, COLD FORM STEEL (18GA #3 DRILL POINT OR THICKER) #12 SCREW #12 SELF -DRILLING SCREW COLD FORM STEEL TO 14 THREADS PER INCH, STRUCTURAL STEEL #5 DRILL POINT #14 SHOULDERED SIMPSON XLSH78B1414 COLD FORM STEEL JAMB TO SCREW SHOULDERED SCREW HEAD OF WALL CONNECTION NOTES: 1. SEE SHEET S1.0 FOR APPROVED FASTENERS 2. GALVANIZED FASTENERS REQUIRED AT ALL EXTERIOR CONNECTIONS 3. CONSULT MANUFACTURER PRODUCT DATA FOR DRILL POINT REQUIRED FOR BASE MATERIAL: (2) SIMPSON FCB 45.5 CLIP AT EA VERT STUD - (1) TOP & (1) BOTTOM OF BM (8) #12 SCREWS EA CLIP - (4) INTO STUD & (4) INTO ANGLE ROOF CLOSURE AT TOWER 314" =1'-0" L6Xi CONT 600T125-54MIL(16GA) W/ (2) #10 SCREWS TO EA HORIZ STUD & W/ (2) #10 SCREWS TO EA VERT STUD 6" MTL STUD 6" CONT CAP TRACK WI (2) #10 SCREWS TO EA STUD & W/ (1) PAF TO STEEL ANGLE @ 16" OC MAX CONT ROOF DECK CLOSURE ANGLE JOIST MECHANICAL UNIT SUPPORT 57.1 314" =1'-0" 'PORT 'E 4X3/8, TYP w Y d w O cMo � o Q ~ rn w < Q z � m d Q w < U N N O Q � N Q J WCO m LL_ co w co Q Lu U O N 0 N Ix a J_ Q w 0 z J H w w x LTH OpLt�c� S MATHERS y m 3 om N 0 N � u U c c g O +• .N N W U C � ui w a d 2 71/2" SEE 16/S7.2 1 FOR PL. �\ 1/2" 114• N ' o JST GIRDER & COL 114 N_ 11/2" 11/2" 17 TOWER COLUMN CONNECTION S7.2 1 112" =1'-0" PL TO JST JOIST GIRDER, SEE PLANS HSS TOWER COLUMN TO JOIST CONNECTION T-0" MIN + + ABOVE T.0 CHANNEL \I ITRACK \ \ 3/16 3" TYP EA JOIST\ TYP \\� 3/16 3' +14 S7.2 \ CONT CHANNEL CONT + CHANNEL, SEE ROOF PLAN (SPACED PER PLAN) TOP OF EXTERIOR WALL JOIST, SEE PLAN NOTE: COORDINATE WITH ARCH DETAILS FOR FLASHING AND WEATHERPROOFING. 13 PARAPET FRAMING PARALLEL TO JOIST CONT TOP TRACK --b #10 SELF -DRILLING SCREW (4 TOTAL @ JOINT) CONT TOP TRACK (4) #10 + + CONT BOT TRACK T-O" MIN ABOVE T.0 CHANNEL 6" MTL \\ \ STUD \ \ t \ SEE ELEV CONT CHANNEL NOTE: COORDINATE WITH ARCH DETAILS FOR FLASHING AND WEATHERPROOFING. PARAPET FRAMING PERPENDICULAR TO JOIST - REAR FASTEN SHEATHING TO FRAMING USING ET&F PANELFAST KNURLED AGS-100 SERIES PNEUMATIC FASTENERS OR #10 BUGLE HEAD SCREWS INTO 5/8" SHEATHING (40/20 SPAN RATING) AND 6" MTL STUDS. 2" OC EDGE SPACING AND 12" OC IN FIELD. SHEAR WALL EXTENTS INDICATED ON FOUNDATION PLAN 15 S7.1 SHEARWALL PANEL STL BM WHERE g SOLID BLOCKING AT APPLICABLE EDGE ANGLE S7.1 FASTEN CONT TOP TRACK TO STL USING (2) PAF @ 16" OC AND WITHIN 8" OF WALL ENDS CONT BRIDGING TOP TRACK STL COL WHERE APPLICABLE )TUD NAILERS FASTENED TO STL COL 7 s7.2 6" MTL STUDS SIMPSON TITEN HD 5/8" DIA x 6" ANCHORS 6 SPACED @ 16" OC AND WITHIN 8" OF WALL S7.2 ENDS 6"CMU BLOCK LAYER SIMPSON S/HD15S ANCH AT SHEARWALL ENDS WITHOUT STL COL. FASTEN TO STUDS USING CONC PEDESTAL FOR (30) #14 SCREWS COL WHERE APPLICABLE 1" DIA THREADED ROD FOUNDATION a ANCH THREADED ROD INTO d ' _ FDN USING SIMPSON SET ' a= ANCHORING ADHESIVE WITH A MIN EMBED OF 9" 8"CMU STEM WALL SILL PLATE NOTES: 1. SEE GENERAL NOTES SECTION 06100 FOR SHEATHING REQUIREMENTS. 2. NO SUBSTITUTIONS ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. 3. INSTALL FASTENERS 3/8" FROM THE EDGES OF THE WOOD STRUCTURAL SHEATHING. 4. ALL PANEL EDGES SHOULD BE SUPPORTED BY FRAMING OR FLAT STRAP BRACING. 5. APPLY DETAILS AS REQUIRED BASED ON SHEARWALL LOCATIONS. 6. PLYWOOD TO BE PLACED PERPENDICULAR TO THE FRAMING. TYPICAL WALL SHEATHING DETAIL in ll.on57.2 3/4„ =1'-01, S7.2 1/4„ =1,-0„ n LOCATION OF SHEATHING T PANELEDGE I MTL STUDS ROOF SHEATHING CONNECTION °I°I°I PER PLAN BY TRUSS MFR II II II 3'-0'MINSHEATHINGTYP PLYWOOD Ex WALL FRAMING, ABOVE T.0 CHANNEL SEE DETAILS + �� 6" MTL STUD I I I I S7.2 I I I LOCATION OF SHEATHING \ V PANEL EDGE I \ PRE-ENGINEERED A V I I I I I I I LI LI J 2" WIDE X 43MIL MIN FLAT MTL TRUSSES (4) #10 \ \ STRAP BLOCKING. INSTALL [___________________ � _ + \ + BLOCKING TAUGHT ACROSS CONNECTION L x x \ CONT CHANNEL LI LI LI STUDS BY TRUSS MFR + + + + \ \ INTERMEDIATE FRAMING I I \ \ \_ 14 FASTENED TO SHEATHING \ S7.2 @ 12" OC LI LI BM, SEE PLANS CONT L2X2X43-MIL100+ \ (18GA) W/#10 SCREWS COL, SEE PLANS TO EA TRUSS AND @ _ _ PANEL EDGE NAILING 6" OC TO PLYWOOD V 0 NOTES: 1. USE COLD -FORMED FRAMING SIZES SPECIFIED IN THE DETAILS 2. BLOCKING TO BE INSTALLEDAT PLYWOOD EDGES - JST, SEE PLAN 3. BLOCKING INSTALLATION PER GENERAL CONTRACTORS NOTE: COORDINATE WITH ARCH DETAILS FOR FLASHING AND WEATHERPROOFING. PREFERENCE - OVER PLYWOOD OR ON STUDS PARAPET FRAMING PERPENDICULAR TO JOIST - 4. FASTEN BLOCKING TO PLYWOOD EDGES PER THESE PLANS 15 LIGHT GAUGE CANOPY FRAMING 11 FRONT ® BLOCKING DETAIL 314" =1'-0" \ \ TYP \ 3/16 \ PLYWOOD SHEATHING (3) SIMPSON PDPA FASTENER TO C CHANNEL 2X2X5" LONG-14GA CLIP W/(4)#10 SELF - DRILLING SCREWS C CHANNEL - SEE PLANS 3/4" =1'-0" CONT TRACK 362T125-33MIL(20GA)(33KSI) W/ (2#10 SCREWS TO EA STUD AND W/ ROOF DECK (2)#10 SCREWS @ 12" OC WITHIN 3" FROM END OF TRACK CUT ENDS OF HEADER AND FASTEN TO STUDS W/ (2) #10 SCREWS MIN 362 S 162-33 M I L(20GA)(33 KS I ) PUNCHED STUD (@ 16" OC) BOX HEADER: [362S162-33MIL (20GA)(33KSI) + 362T125-33MIL (20GA)(33KSI)] ATTACH STUD TO TRACK FLANGES W/ #10 SCREWS @ 12" OC MAX CONT TRACK 362T125-33MIL(20GA)(33KSI) W/ (2#10 SCREWS TO EA STUD AND W/ (2) CONC SLAB -ON -GRADE PAF W/ 1 112" EMBED TO CONC @ 16" OC AND WITHIN 3" FROM END OF TRACK NOTE: IF DRYWALL DOES NOT CONTINUE TO TOP TRACK, BRIDGING MUST BE INSTALLED AT THE MID -HEIGHT OF THE WALL. PARAPET BRACE CONNECTION DETAIL 10 TYPICAL INTERIOR FRAMING DETAILS 1" =1'-0" 57.2 314" =1'-0" 112" =1'-0" CL NEXT STUD SHALL BE 6" WIDTH USE 400S162-54 [50] STUDS AND 40OT125-54 [50] TRACK USE 6" MEMBERS ON ONE SIDE FASTENED PER COL OF COL AND FASTENED PER SHEARWALL END DETAIL COL SHEARWALL END DETAIL ALIGN FRAMING -� TO WALL EDGE HSS STL COL - COLUMN AT SHEARWALL END(S): CORNER CONDITION - 600S162-54MIL(16GA)(50KSI) 600T125-54MIL(16GA)(50KSI) TRACK STUD FASTENED TO STL COL W/ FASTENED TO CHANNEL THROUGH (2) ROWS PAF @ 12" OC AND FLANGES W/ #10 SCREWS @ 12" OC WITHIN 6" OF STUD ENDS INSTALL BOTH SIDES IF z 600S162-54MIL(16GA)(50KSI) STUD SHEARWALLS ARE BOTH FASTENED TO TRACK W/ (2) ROWS OF SIDES OF COL #10 SCREWS @ 12" OC HSS STL COL - COLUMN AT SHEARWALL END(S) - LATERAL COLUMN CONNECTION 1 1/21'=1'-0" (2) 600S162-54MIL (16GA)(50KSI) BACK-TO-BACK (2) ROWS #10 SCREWS @12"OC TYPICAL SHEARWALL CHORD S7.2 3" =1'-0" PROVIDE 2" WIDE STRAPPING ACROSS ALL PLYWOOD PANEL JOINTS WALL SHEATHING BLOCKING DETAIL 1" =1'-0" 6" MTL STUD CONT BRIDGING WALL SHEATHING v 60OT12543 [33-KSI] WALL FRAMING STUD CONT CAP TRACK FASTENED TO LEDGER USING #10 @ 12" OC EA FACE TRUSS CONNECTION BY OTHERS 600S182-54 [50-KSI] CONT LEDGER FASTENED TO EA WALL STUD USING (3) #10 SCREWS THROUGH THE SHEATING NOTE: LEDGERS ARE REQUIRED AT TOP AND BOTTOM OF CANOPY TRUSSES TO FACILITATE THE REQUIRED CONNECTIONS. COORDINATE WITH TRUSS MANUFACTURERS DRAWINGS FOR FINAL ELEVATION AND LOCATION REQUIREMENTS. LEDGER DETAIL 1 112" = V-0" CONNECTION BY TRUSS ENGINEER PRE- ENGINEERED MTL TRUSS FACIA PER ARCH PLANS 1 15'-2" TRUSS BEARING PARAPET FRAMING - SEE DETAILS FOR FRAMING AND CONNECTION NOTE: REFER TO PARAPET DETAILS FOR PARAPET FRAMING REQUIREMENTS (NOT SHOWN). REAR TOWER ENTRY FRAMING 112" =1'-0„ SHEET GENERAL NOTES 1. SEE GENERAL NOTES AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS NOT SHOWN HERE TO INCLUDE PAINTING / COATING REQUIREMENTS. 2. DETAILS FOR CONNECTIONS ARE SCHEMATIC. STEEL FABRICATOR SHALL PROVIDE FINAL CONNECTION DESIGN. LIGHT GAUGE METAL SUPPLIER SHALL ADOPT REQUIRED COMPONENTS AS SHOWN IN THE DETAILS AND ADJUST TO SPECIFIC FIELD CONDITIONS. EXTERIOR COLD FORM FRAMING NOTES ITEM NOTES COMMENTS 6" WALL STUDS 600S162-54MIL(16GA)(50KSI) PUNCHED ALL EXTERIOR STUD SPACED @ 16" OC MAX WALLS 6" CONT TOP TRACK CONT 600T125-54MIL(16GA)(50KSI) W/ (2) #10 SCREWS TO EA STUD 6" CONT BOT TRACK CONT 600T125-54MIL(16GA)(50KSI) W/ (2) #10 @ ROOF DECK SCREWS TO EA STUD & (2) #10 SCREWS TO ROOF DECK @ 12" OC & AT EA END OF TRACK 6" CONT BOT TRACK CONT 600T125-54MIL(16GA)(50KSI) W/ (2) 0.157" @ STL CHANNELS DIA PAF TO STL CHANNEL @ 12" OC & AT EA END OF TRACK 6" CONT BOT TRACK SIMPSON TITEN HD 5/8" DIA X 6" ANCHORS TO FOUNDATION SPACED @ 16" OC & WITHIN 8" OF WALL ENDS CONT BRIDGING CONT COLD ROLLED (U-CHANNEL) & SIMPSON N-0" OC VERT SPACING & 12" STRONG -TIE SUBH3.25 W/ (1) #10 SCREW TO FROM EA END OF STUD CONT CHANNEL COLD FORM CONNECTOR NOTES FASTENER TYPE FASTENER INFORMATION APPLICATION COMMENTS PAF GALVANIZED - 0.157' DIA EXTERIOR APPLICATIONS SIMPSON PDPA OR POWDER ACTUATED FASTENER HILTI X-U PAF PAF 0.157" DIA POWDER ACTUATED INTERIOR APPLICATIONS SIMPSON PDPA OR FASTENER HILTI X-U PAF #10 SCREW #10 SELF -DRILLING SCREW COLD FORM STEEL TO 16 THREADS PER INCH, METAL DECK #1 DRILL POINT #10 SCREW #10 SELF -DRILLING SCREW COLD FORM STEEL TO 16 THREADS PER INCH, COLD FORM STEEL (18GA #3 DRILL POINT OR THICKER) #10 SCREW #10 SELF -DRILLING SCREW COLD FORM STEEL TO 24 THREADS PER INCH, STRUCTURAL STEEL #3 DRILL POINT #12 SCREW #12 SELF -DRILLING SCREW COLD FORM STEEL TO 14 THREADS PER INCH, COLD FORM STEEL (18GA #3 DRILL POINT OR THICKER) #12 SCREW #12 SELF -DRILLING SCREW COLD FORM STEEL TO 14 THREADS PER INCH, STRUCTURAL STEEL #5 DRILL POINT #14 SHOULDERED SIMPSON XLSH78B1414 COLD FORM STEEL JAMB TO SCREW SHOULDERED SCREW HEAD OF WALL CONNECTION NOTES: 1. SEE SHEET S1.0 FOR APPROVED FASTENERS 2. GALVANIZED FASTENERS REQUIRED AT ALL EXTERIOR CONNECTIONS 3. CONSULT MANUFACTURER PRODUCT DATA FOR DRILL POINT REQUIRED FOR BASE MATERIAL: 6" MTL STUD (4) #12 SCREWS SIMPSON FCB4 FIXED -CLIP CONNECTOR 1/41 \ 2-12 CONT L4X4X3/8 (4) #12 SCREWS 1/4 2-12 BM SIZE VARIES TOWER COLD -FORMED BYPASS FRAMING CONNECTIONS 1 112„ =11-019 ROOF SHEATHING PRE-ENGINEERED MTL TRUSSES, @ 24" OC ... PRE-ENGINEERED TRUSS MFR TO PROVIDE TRUSS CONT TOP TRACK CONNECTION TO RESIST ALL WIND AND SEISMIC LOAD REQUIREMENTS WALL SHEATHING 1l4 2-12 SIMPSON FCB4 FIXED -CLIP • 1/4 2.12 CONNECTOR AT STUD (8) #12 SCREWS - (4) TO STUD L4X4X3/8 & (4) TO ANGLE 6" MTL STUD TOWER COLD -FORMED FRAMING AT TOP OF WALL 11" =1'-0" h 1 cs Io M 00 ►a gOw p` p NC% P.4W 3 w Y d w O cMo 2ii o rn d z � m Q w < U N CV O Q � Q W J m w Lo cOfl Of O <i3: C7 of zLu Q a' L) O N 0 N I a J Lij z J H w LL w x O�LTH Op47 WILI�M S MATHERS a m 7 O N N 0 rn N � u tq c c g O +• .N 8 N W C � w a d 2 3/8' DIA THREADED ROD (ASTM F 1554 GRADE 36) W/ 6" EMBED. USE SIMPSON SET-XP EPDXY ANCHORING SYSTEM SIMPSON SSC4.25 AT TOP (HEADER ONLY) 21/2" 11/4" MC6X18 x JAMB FRAMING x 7 x S7.3 6X6X3/4" PL x io g^ HEADER/SILL �� SIMPSON SSC4.25 (LLV) W/ (5) #10 SCREWS INTO JAMB AND (4) #10 SCREWS INTO HEADER/SILL 16 ROLLUP DOOR FRAME ATTACHMENT HEADER/SILL TO JAMB CONNECTIONS 1 112" = V-0" CFS FRAMING, OPENING JAMB MC6X18 TYP (2) SIMPSON SSC4.25 W/ (5) #10 INTO JAMB OR (2) TYP 3l1 ATTACH CFS JAMB L3X3X54MIL (16GA)(50KSI) STUD TO STL 6" LONG W/ (6) #10 CHANNEL W/ (2) PAF SCREWS TO JAMB @ 12" OC MAX OR WI (2) #12 SCREWS @ COORDINATE 12" OC MAX. GROUTED 6"CMU ROUGH PROVIDE 3" MIN OPENING W/ BETWEEN ANCH ARCH x x 16 3/8" DIA THREADED ROD S7.3 3/16 (ASTM F1554 GRADE 36) W/ 6" MIN EMBED. USE SIMPSON SET- XP EPDXY m ANCHORING SYSTEM FOR OPENINGS ..a a . m Q. LARGER THAN 6FT 15 ROLLUP DOOR FRAMING 57.3 112" = l'-0" PROVIDE 1" GAP BETWEEN EDGE OF STUD AND BOT OF STL BM OPENING JAMB STL BM SIMPSON SCW5.5 WI (4) #12 SCREWS INTO BM AND (3) #14 SHOULDERED SCREWS INTO JAMB NOTE: FOR OPENINGS LARGER THAN 6FT: (2) CLIPS. ONE ON EA SIDE OF JAMB FOR OPENING EQUAL OR LESS THAN 6FT: (1) CLIP JAMB CONNECTION 1 112" =1'-0" L6X4X3/8 -12" LONG W/ L.L.V 1/4" 3 SIDES MTL DECK L2X2X1/4 JST REINFORCEMENT REQ'D TO BE INSTALLED VERTICALLY AT EA JAMB CONNECTION. WELD ALL- AROUND TO JST CHORDS. WELD A MIN 2" FILLET TO L6X4 CLIP. USE 3/16" MIN FILLET WELDS SIMPSON SCB47.5 EA SIDE OF JAMB. FASTEN EA CONNECTOR TO JAMB W/ (3) #14 SHOULDERED SCREWS. FASTEN EA CONNECTOR TO ANGLE USING (3) #12 SCREWS. SEE NOTE BELOW JAMB STUDS STL JST NOTE FOR SCB47.5 CLIP: FOR OPENINGS LARGER THAN 6FT: (2) CLIPS. ONE ON EA SIDE OF JAMB FOR OPENING EQUAL OR LESS THAN 6FT: (1) CLIP JAMB CONNECTION @ SIDE WALLS 1" =1'-0" 1PENING JAMB IMPSON SSC4.25 WI i) #10 INTO JAMB OR 1) L3X3X54MIL(16GA) iOKSI) 6" LONG V/ (6) #10 SCREWS TO AMB ;ROUTED 6" CMU 3/8" DIA THREADED ROD (ASTM F1554 GRADE 36) W/ 6" MIN EMBED. USE SIMPSON SET- XP EPDXY ANCHORING SYSTEM FOR OPENINGS EQUAL OR LESS THAN 6FT 11 JAMB TO FOUND. CONNECTIONS S7.3 1" =1'-0" #10 SCREW @ 12" OC #10 SCREW AT STUD FACE HEADER DETAIL 3" =1'-0" NOTE: ONLY REQUIRED AT WINDOWS SILL SECTION 3„ =1'-0" 6" MTL STUD (2) 60OT125-54MIL(16GA)(50KSI) (2) 6005162-54MIL(16GA)(50KSI) #10 SCREWS @ 12" OC (TYP) (2) ROWS #10 SCREWS @ 12" OC 60OT125-54MI L(16GA)(50KSI ) 60OS162-54MI L(16GA)(50KSI ) #10 SCREWS @ 12" OC AT FACE, TYP #10 SCREW AT STUD FACE 60OT125-54MI L(16GA)(50KSI ) 6" MTL STUD #10 SCREWS @ 12" OC (2) ROWS #10 SCREWS @12"OC JAMB: [(3)60OS162-54MIL (16GA)(50KSI) + (3)600T125-54MIL (16GA)(50KSI)] FOR OPENINGS LARGER THAN 6FT TYPICAL JAMB JAMB STUDS AND TRACKS.SEE JAMB DETAIL SIMPSON SCC4.25 CONNECTOR, TOP AND BOTTOM. SEE 12IS7.3 #10 SCREWS @ 12" OC JAMB: [(1)600S162-54MIL (16GA)(50KSI) + (1)60OT125-54MIL (16GA)(50KSI)] FOR OPENINGS EQUAL OR LESS THAN 6FT 60OT125-54MIL(16GA) TRACK PIECE, MIN 6" LONG. CONNECT WI (6) #10 SCREWS TO JAMB AND (3) #10 SCREWS TO HEADER, (3) EA SIDE FUK HEAUEK 61 UUS AND TRACKS, SEE HEADER DETAIL. HEADER CONNX TO JAMB STUD 314" =1'-0.. 6" I 6:) TYP. WALL OPENING S7.3 112" =1'-0" 6" MTL STUDS 8 S7.3 6" MTL STUDS 5 TYP. WALL OPENING S7.3 112" =1'-0" 9 S7.3 10 S7.3 NOTCH TRACK LIPS AND VERT TRACK CONNECTION 14 S7.3 13 S7.3 12 tS7.3 8 57.3 12 S7.3 #10-16 HWH SCREWS OC, TYP, MAX 611 ALUMINUM STAND, SEE PLANS. CHANNEL, SEE PLANS (4) 3l8" DIA SAE GRADE 5 THREADED RODS Wl3/4" MIN WASHERS AND LOCKING NUTS PROVIDE A LAYER OF FELT PAPER OR RUBBERIZED ASPHALT MEMBRANE BETWEEN STAND ALUMINUM BASE PLATE AND STEEL CHANNEL (2) 3X3X1/4" 6061-T6 CONT ALUMINUM ANGLE TO MATCH BP FOOTPRINT �4 STAND COLUMN CONNX. BETWEEN JOIST S7.3 1 1/2" = V.D., CHANNEL CONNX. TO JOIST S7.3 1 112" = l'-0" 3/4" STRUCTURAL PLYW( #10 WOOD SCREWS @ 6' ALL (4) SII (2) CONT 2X12 PT STUDS. ATl STUDS TO EA OTHER W/ (2 COMMON NAILS @ 6" OC I ATTACH T&B PL TO 2X12 A COMMON NAILS @ 1" MASTERBUILT SUPPORT 314" =1'-0" REFRIGERATION FRAMING DETAIL 314" =1'-0" oonVIDE A LAYER QF FELT =R OR RUBBERIZED iALT MEMBRANE KEEN STAND ALUMINUM PLATE AND STEEL VNEL VNEL, SEE PLANS FORCEMENT D AT JST N CHANNEL AT PANEL POINT JST, SEE PLANS SHEET GENERAL NOTES 1. SEE GENERAL NOTES AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS NOT SHOWN HERE TO INCLUDE PAINTING / COATING REQUIREMENTS. 2. DETAILS FOR CONNECTIONS ARE SCHEMATIC. STEEL FABRICATOR SHALL PROVIDE FINAL CONNECTION DESIGN. LIGHT GAUGE METAL SUPPLIER SHALL ADOPT REQUIRED COMPONENTS AS SHOWN IN THE DETAILS AND ADJUST TO SPECIFIC FIELD CONDITIONS. EXTERIOR COLD FORM FRAMING NOTES ITEM NOTES COMMENTS 6" WALL STUDS 60OS162-54MIL(16GA)(50KSI) PUNCHED ALL EXTERIOR STUD SPACED @ 16" OC MAX WALLS 6" CONT TOP TRACK CONT 60OT125-54MIL(16GA)(50KSI) WI (2) #10 SCREWS TO EA STUD 6" CONT BOT TRACK CONT 60OT125-54MIL(16GA)(50KS1) WI (2) #10 @ ROOF DECK SCREWS TO EA STUD & (2) #10 SCREWS TO ROOF DECK @ 12" OC & AT EA END OF TRACK 6" CONT BOT TRACK CONT 60OT125-54MIL(16GA)(50KSI) WI (2) 0.157" @ STL CHANNELS DIA PAF TO STL CHANNEL @ 12" OC & AT EA END OF TRACK 6" CONT BOT TRACK SIMPSON TITEN HD 5/8' DIA X 6" ANCHORS TO FOUNDATION SPACED @ 16" OC & WITHIN 8" OF WALL ENDS CONT BRIDGING CONT COLD ROLLED (U-CHANNEL) & SIMPSON 4'-0' OC VERT SPACING & 12" STRONG -TIE SUBH3.25 W/ (1) #10 SCREW TO FROM EA END OF STUD CONT CHANNEL COLD FORM CONNECTOR NOTES FASTENER TYPE FASTENER INFORMATION APPLICATION COMMENTS PAF GALVANIZED - 0.157" DIA EXTERIOR APPLICATIONS SIMPSON PDPA OR POWDER ACTUATED FASTENER HILTI X-U PAF PAF 0.157" DIA POWDER ACTUATED INTERIOR APPLICATIONS SIMPSON PDPA OR FASTENER HILTI X-U PAF #10 SCREW #10 SELF -DRILLING SCREW COLD FORM STEEL TO 16 THREADS PER INCH, METAL DECK #1 DRILL POINT #10 SCREW #10 SELF -DRILLING SCREW COLD FORM STEEL TO 16 THREADS PER INCH, COLD FORM STEEL (18GA #3 DRILL POINT OR THICKER) #10 SCREW #10 SELF -DRILLING SCREW COLD FORM STEEL TO 24 THREADS PER INCH, STRUCTURAL STEEL #3 DRILL POINT #12 SCREW #12 SELF -DRILLING SCREW COLD FORM STEEL TO 14 THREADS PER INCH, COLD FORM STEEL (18GA #3 DRILL POINT OR THICKER) #12 SCREW #12 SELF -DRILLING SCREW COLD FORM STEEL TO 14 THREADS PER INCH, STRUCTURAL STEEL #5 DRILL POINT #14 SHOULDERED SIMPSON XLSH78BI414 COLD FORM STEEL JAMB TO SCREW SHOULDERED SCREW HEAD OF WALL CONNECTION NOTES: 1. SEE SHEET S1.0 FOR APPROVED FASTENERS 2. GALVANIZED FASTENERS REQUIRED AT ALL EXTERIOR CONNECTIONS 3. CONSULT MANUFACTURER PRODUCT DATA FOR DRILL POINT REQUIRED FOR BASE MATERIAL: REFRIGERATION UNIT SECURED TO FRAMING USING 1l2"X5" LAG SCREWS (8) TOTAL, (4) EA SIDE (2) CONT 2X8 PT STUDS. ATTACH STUDS TO EA OTHER WI (2)10d COMMON NAILS @ 6" OC MAX. OVERLAP PLATES AT CORNERS WI (4)10d COMMON NAILS 2X4 PT STUDS @ 12" OC ATTACHED T&B PL TO 2X4 WI (2)16d COMMON NAILS (2) CONT 2X8 PT STUDS. ATTACH STUDS TO EA OTHER WI 1/4"X3" SIMPSON SDS25300 SCREWS @ 6" OC MAX STAGGERED. OVERLAP PLATES AT CORNERS W/ (4) SCREWS. PROVIDE 3" MIN SPACING, 6" MIN END DISTANCE 1 1/2" MIN EDGE DISTANCE ATTACH CONT 2X8 PT STUD TO METAL DECK W/ (2) #10 WOOD TO METAL SCREWS @ 12" OC MAX. PROVIDE 3" MIN SPACING, 6" MIN END DISTANCE & 1 1/2" MIN EDGE DISTANCE IN WOOD PLATE 3/4" PRESSURE TREATED PLYWOOD SHEATHING CONDENSING UNIT, SEE MECH DWG'S. CONNECTION TO STRUCTURE BY UNIT MFR'S W Vm V� w Y d w G' O cMo � o Q ~ rn d z m Q w U N Q N O Q � Q I W J E > coC:ocOfl CO Lo Of O Lu 0 of z U �J� w O = N 0 N Ix0 a NLT14 Opts WILLIM S MATHERS y m 3 O N 0 rn N � W c c g O +" 2 'C H N w rn C � ui w a d 2 T - 0" MAX MTL DECK STL JST CL 45 CL 3x1 1l2"x54-MIL(16 GA) CLIP 8" LONG MIN W/ (4) #10-16 HWH SCREWS THROUGH LONG LEG TO z LATERAL BRACING @ STUD AND WI (2) BUILDEX #12-24 b 4'-0" OC MAX HORIZ TEK #5 SELF -DRILLING SCREWS OR W/ (2) 0.157" DIA SIMPSON PDPA TO STL JST I � 362S162-33MIL(20GA)(33KSI) @ 16" OC MAX W/ (4) #10-16 HWH SCREWS AT EA STUD TO STUD CONNECTION CONT 362T125-33MIL(20GA)(33KSI) W/ (2) #10-16 HWH SCREWS TO EA STUD MAX t4 INTERIOR FASCIA DETAIL S7A 112" =1'-0" CONT 2X12 W/ (3) SIMPSON TB1475S WOOD TO STEEL SCREWS AT EA STUD LOCATION CONT 2X12 W/ (2)10d COMMON NAILS @ 6" OC CONT 2X12 W/ (3) SIMPSON 2X12 TO FULLY BEAR ON TB1475S WOOD TO STEEL STEEL SCREWS AT EA STUD 2 LOCATION S7.4 2 S7.1 "I" i W BEAM, _ _ - J SEE PLAN 2X12 W BEAM, SEE PLAN EXTERIOR COLD FORMED STEEL WALL FRAMING CATWALK SECTION AT TOWER HORIZ CONT 2X6 TOP RAIL W/ (2)16d COMMON NAILS R-60 MAX 2X6 TOP RAIL W/ (2) 4X4 POST @ 3'-6" OC MAX, 16d COMMON NAILS SEE PLAN INTO EA POST 2X6 MID RAIL W/ (2) c 16d COMMON NAILS INTO EA POST 2X6 KICK RAIL W/ (2) SIMPSON DTT2Z WI (8)#14X1 1/2" 16d COMMON NAILS LG. SDS & (1)1/2" DIA A307 THRU INTO EA POST BOLT W/ WASHER & NUT AT EA EXTEND 2X 16" MIN SUPPORT POST FROM EDGE OF CATWALK DBL 2X12 FLOOR JOIST. _ _ 3 ATTACH 2X W/ (2)10d NAILS @ 12" OC MAX SIMPSON LJS210-2 HANGER, TYP AT EA END OF DOUBLE 5/8" PLYWOOD SHEATHING 2X12 BEAMS FASTENED TO JSTS W/ 10d COMMON NAILS @ 8" OC 2X12 STUD �2 CATWALK SECTION 57.4 3/4" = V-0" HORIZ CONT 2X6 TOP RAIL W/ RTU RTU (2)16d COMMON NAILS UNIT CURB RTU 2X6 TOP RAIL W/ (2)16d (14GA MIN) UNIT CURB COMMON NAILS INTO EA POST MOUNTING CLIPS (3) #12 SCREWS W/ UNIT CURB (14GA MIN) MOUNTING BY GC PLASTIC WASHERS AT (14GA MIN) YLIGC 2X6 MID RAIL W/ (2)16d EA PL LOCATION MOUNTING CLIPS COMMON NAILS INTO EA POST g SHOWN ABOVE BY GC 4 PL 1/8"X3"X20" AT EA CORNER 2X6 KICK RAIL W/ (2) 16d 4X4 POST @ 3'-6" OC MAX, #12 SCREW @ z OF UNIT. (3) STRAPS MIN OR COMMON NAILS INTO EA POST SEE PLAN 6" OC, TYP @ S-0" OC MAX 3/8" A307 z PROVIDE CONT PT WOOD THROUGHBOLTS W/ ROOF DECK EDGE ANGLE MTL ROOF BLOCKING FOR CURB SUPPORT WASHERS & NUTS ON BOTH SIDES @ 12" OC MTL ROOF MTL ROOF DECK DECK z ALL AROUND PROVIDE PT WOOD DECK BLOCKING FOR CURB SUPPORT 5/8 6" CTRS 2X6 HOST, -PEA SIDE OF MTL ROOF 4X4 POST, TOP & BOT 5/8 6" CTRS DECK (3) #12 TEK5 SCREWS AT EA PL LOCATION SHOWN ABOVE 2X12 TOP PL WI0.157" DIA FASTEN TOP PL TO BOT PL USING SIMPSON PDPA OR HILTI X-U 10d COMMON NAILS @ 6" OC STAGGERED STL ANGLE CLEAN AND PREPARE WELDS, SEE DETAILS SCREWS MUST PENETRATE STL ANGLE CLEAN AND PREPARE WELDS, SEE DETAILS PAF INTO WOOD PL & STL &B (2) EBM A SIDE OF POST -_T&B� AND PAINT WITH ZRC COLD A MIN OF THREE THREAD AND PAINT WITH ZRC COLD @ 8" OC STAGGERED 2 SIMPSON 2.5A CONNECTORS FULLY NAILED W GALVANIZING COMPOUND PITCHES BEYOND THE STL ANGLE GALVANIZING COMPOUND BETWEEN POSTS 5 8d NAILS INTO 2X6 HORIZ & 5 8d NAILS (T&B) PER MFR METAL SUBSTRATE SEE DETAILS PER MFR INTODBL2X TOP PL - (1) CONNECTOR AT EA RECOMMENDATIONS RECOMMENDATIONS SIMPSON L70 FULLY NAILED W/ (8) 2X6 HORIZ AT BOT FLANGE OF BM 10dX1 1/2" LG NAILS, (4) INTO DBL OPTION 1 - HOLD DOWN STRAP TO STEEL ANGLE OPTION 2 - BOLT TO STEEL ANGLE OPTION 3 - WELD TO STEEL ANGLE 2X12 TOP PL & (4) INTO 2X6 HORIZ MECHANICAL UNIT CURB ATTACHMENT GUARDRAIL POST DETAIL S7A 112" = V-0" W Y d w G O coo o Q ~ rn d z � m U N Q CV O Q � Q � W J � > m Cn w � Cco .0 Of O (D Of Z L) Q LL O N U 0 N i a U) J_ Q w 0 Cz G J H W LL w x U) vALTH 6;��� UO WILJLIAM S MATHERS a m 3 (1 N 0 N � N � c c g O + N w c� ui w a d z s 2 E \ k / § \ \ < < 4 / C=) & > 3 « » Ea E_ C) co \ k / LU \ \ j k k j \CL 3: W ± > E 0 2 M �XLT6 o ° « //ILLIAM s _E y 2 2( k ) § 0 � �§ ui ) « ¢ § ills k� 0� k� k� S8.0 GENERAL NOTES 1. EXTERIOR FOOTINGS HEREIN ARE RELATIVE TO ADJACENT GRADE. THE TOP OF ALL EXTERIOR FOOTINGS SHALL BE:-2'-0". 2. SEE ARCH / PLUMBING DRAWINGS FOR DRAIN SLOPES, ELEVATIONS AND SLAB RECESSES. 3. OPENING / RE-ENTRANT CORNER, TYP. PROVIDE (2) #4 X 4'-0' LONG BARS AT MID -HEIGHT OF SLAB. WALL FOUNDATION SCHEDULE MARK WIDTH FOUNDATION THICKNESS TOP REINF. BOTTOM REINF. WF4 4' - 0" 1' - 0" (4) #5 CONT & #5 @ 18" OC TRANS (4) #5 CONT & #5 @ 18" OC TRANS POST BY OTHERS,SEE PLANS 24" DIA ROUND CONC PIER, CAST W/ FTGS T.O. FLOOR SLAB D, - 0" COLUMN ENCASED IN CONCRETE 3/4" 11-0" MATCH WALL BOND BEAM, SEE PLAN FOR REINF CONCRETE PRE -CAST LINTEL. MATCH WALL WIDTH CMU LINTEL / BOND BEAM AT DOOR 11 CROSS SECTION S9.0 1 112" =1'-0" HORIZ. JOINT REINFORCING REINFORCEMENT F (3 TOTAL) HORIZONTALJOINT REINFORCEMENT TYPICAL REINFORCEMENT - REINFORCING (2) TOTAL N I 6" MIN. S ON FILELAPD FORMED CORNERS AT CORNERS - NOTE: SEE TYPICAL WALL SECTIONS FOR REINFORCING SIZE AND SPACING REQUIREMENTS. (2) POURED AND REINFORCED CELLS I CONTROL JOINT ON EACH SIDE OF CONTROLJOINT. CMU WALL NOTES: 1. BOND BEAM REINFORCEMENT SHALL BE CONTINUOUS ACROSS JOINT. 2. CUT CMU IN FIELD THROUGH WALL PRIOR TO GROUTING. 3. DO NOT CUT BOND BEAM REINFORCEMENT. 4. REINFORCED CELLS SHALL MATCH WALL REFORCEMENT REQUIREMENTS. IF WALLS ARE DOUBLY REINFORCED, THE REINFORCED CELLS WILL REQUIRE (2) BARS IN EACH. 5. WEATHERPROOF JOINT. REFERENCE ARCHITECTURAL DETAILS. CMU CONTROL JOINT_ S9.0 1" =1'-0" CSEi:T:11DIM MIN SPLICE LENGTH AT CORNERS/INTERSECTIONS TYPICAL 0. CORNERS CONTINUITY CORNER, TYP .0. WALL = 8'-8" A.F.F. MAX, ;EE ARCH TINGLE COURSE BOND BEAM, TEE PLAN FOR REINF CMU, SEE PLAN FOR REINF 'ROUT SOLID ALL CELLS BELOW 'RADE TOWEL TO MATCH VERT REINF, ;EE PLAN SEE PLAN & FTG SCHED FOR SIZE, DEPTH & REINF REQ'D IN FTG'S SAWCUT, FILL W/ JOINT FILLER AT EXPOSED JOINTS, SEE SPECIFICATIONS 1/8" WIDE X T/4 DEEP SAWCUT JOINT SAWCUT JOINT TYP "C.J" SLAB JOINT NOTES: 1. SEE PLAN FOR SLAB THICKNESS "T", REINFORCING AND SUBBASE. 2. CONTROL JOINTS TO BE EITHER A SAWCUT OR CONSTRUCTION JOINT. 3. SAWCUT JOINT SHALL BE 1/8" WIDE X T/4 DEEP CUT MADE WITHIN 2 HRS MIN AND 12 HRS MAX AFTER CONCRETE PLACEMENT WITHOUT RAVELING AND BEFORE RANDOM CRACKS OCCUR. GENERAL SLAB JOINT INFORMATION W4" =1'-0" CONC SLAB, SEE PLAN STD HOOK -9a A ° 1L 1 (2) #4 CONT N � U g d a a. wOR- U 3" SEE PLAN CLR FOUNDATION DETAIL STD HOOK e (2) #5 CONT GROUT SOLID ALL CELLS BELOW GRADE DOWELS TO MATCH VERT REINF, SEE PLAN SEE PLAN & FTG SCHED FOR SIZE, DEPTH & REINF REQ'D IN FTGS CONC SLAB, SEE PLAN SLAB TRANSITION DETAIL S9.0 W4" =1'0" - a m- J 1 (2) #5 CONT SLAB, SEE PLAN i00K CONT STRUCTURAL 3D VIEW 26' - 8" hvi:v- r — I I I I I — — — — — — — — — — — — — — — — — — — — - `v 5 SEE NOTE 3 >< 8" CMU WALLS AT TRASH COMPOUND W/ (1) S9.0 #5 VERT (EDGE SPACING) REINF FILLED CELLS @ 32" OC. PROVIDE SAME REINF 6' CONC SLAB W/ 4000 PSI CONC W/ #4 BARS FILLED CELL EA CORNER, INTERSECTION @12" OC EW CENTERED IN SLAB AND WALL ENDS. PROVIDE SINGLE COURSE COMPACTED SOIL IN ACCORDANCE WI BOND BEAM W/ (2) #5 CONT AT TOP OF CMU, GEOTECHNICAL REQUIREMENTS AT TRASH T.O. MASONRY = 8'-8" A.F.F. MAX, SEE ARCH. PROVIDE FILLED CELL W/ (2) #5 COMPOUND SLAB GROUT ALL CELLS BELOW GRADE SOLID VERT (EDGE SPACING) EA SIDE OF OPENING AT JAMBS. PROVIDE LL a 1 1 8" X 8" PRECAST LINTEL BASE W/LL 1 (2) #5 CONT ABOVE OPENING 1 7 C.J., TYP s9.o 6-0" EMBEDMENT ON CENTER GATE POSTS POST BY ONLY OTHERS, TYP (4) ri L -0 J 4 S9.0 12 S9.0 8" CONC SLAB W/ 4000 PSI CONC W/ #4 BARS @12" OC EW CENTERED IN SLAB COMPACTED SOIL IN ACCORDANCE W/ GEOTECHNICAL REQUIREMENTS AT TRASH COMPOUND SLAB 3 S9.0 W Y d W G' O cMo � o Q ~ rn m a Z � Q w U N Q N Q � O > Ld J W� ti M m � Z W Q cfl w ~ O Z Lu Of U O N 0 0 N ix o a LTp WLL M S MTHERS 4372 0ONAL N N 0 O rn N N 3 fn c c O g u ' I H U Lu 0 H ui w a d z i o z �7 11 H LL L LL t"'J LLQ LU O Y Q 0 a a TYPICAL CMU DETAILS 1., = 1.-0.1 WALL SECTION 3/4" = 1'-0" FOUNDATION DETAIL 3/4" = 1'-0" FOUNDATION PLAN 1/4" = 1'-0" S9.0