HomeMy WebLinkAboutSDP000000333 Plan - Approved 2023-04-07WALTON MIDDLE SCHOOL SEPTIC PROJECT
SITE DATA:
ENGINEER: TIMMONS GROUP
608 PRESTON AVENUE, SUITE 200
CHARLOTTESVILLE, VA 22903
TELEPHONE: 434- 327-1681
CONTACT: JONATHAN SHOWALTER, P.E.
J ONATHAN. SHOWALTER@TI M MON S. COM
TAX MAP PARCEL: 10100-00-00-056AO
LIMITS OF DISTURBANCE: 8,600 sf
ZONING: RURAL AREA
MAGISTERIAL DISTRICT: SAMUEL MILLER DISTRICT
SOURCE OF BOUNDARY AND TOPOGRAPHY: TIMMONS GROUP.
28 IMPERIAL DRIVE
STAUNTON, VA24401
(540)-885-0786
SOURCE TOPOGRAPHY: TIMMONS GROUP, JANUARY 27, 2023
DATUM: HORIZONTAL: NAD83 VIRGINIA STATE GRID SOUTH ZONE
VERTICAL: NAVD88
SITE AREA: 50.00 ACRES
PROPOSED USES: DEMOLITION OF EXISTING SEPTIC TANKS AND CONSTRUCTION OF NEW
SEPTIC TANKS AND SEWER LINES.
WETLAND IMPACTS: NONE
THERE ARE NO CRITICAL SLOPES LOCATED WITHIN THE PROJECT LIMITS.
THERE ARE NO CONSTRUCTION ACTIVITIES PROPOSED WITHIN THE 100-YR FLOODPLAIN.
LETTER OF REVISION TO
SDP00000333
ALBEMARLE COUNTY
3/15/2023
708
— PROJECT
y AREA
0 2a
^N 1p
r
708
n` J
1 �%r
VICINITY MAP
SCALE: 1" = 1000'
OWNER:
COUNTY OF ALBEMARLE SCHOOL BOARD
CONTACT: KAGAN SQUIRE
2751 HYDRAULIC ROAD,
CHARLOTTESVILLE, VA 22901
TELEPHONE: 434-975-9340 EXT. 11030
ENGINEER OF RECORD:
TIMMONS GROUP
608 PRESTON AVE.
CHARLOTTESVILLE, VA 22903
CONTACT: JONATHAN SHOWALTER, P.E.
TELEPHONE: 434-327-1681
Sheet List Table
Sheet Number
Sheet Title
C0.0
COVER SHEET
C1.0
NOTES & DETAILS
C2.0
EXISTING CONDITIONS & DEMOLITION PLAN
C3.0
LAYOUT PLAN
C4.0
SANITARY SEWER PROFILES
TOTAL SHEETS = 5
SIGNATURE PANEL:
APPROVAL DATE
DEPARTMENT OF COMMUNITY DEVELOPMENT
PLANNING & ZONING
ENGINEERING
INSPECTIONS
E911
DEPARTMENT OF FIRE AND RESCUE
ALBEMARLE COUNTY SERVICE AUTHORITY
VIRGINIA DEPARTMENT OF TRANSPORTATION
VIRGINIA DEPARTMENT OF HEALTH
ARCHITECTURAL REVIEW BOARD
am
O
oc
x
H
Z
O
E
ce
U
W
C)
z
O
W
W
H-
DATE
3/15/2023
DRAWN BY
S. KIRBY
DESIGNED BY
S. KIRBY
CHECKED BY
J. SHOWALTER I
SCALE
AS SHOWN
U
I�
Lu
w
(f)
Q=
U
co
zU
>
oX
O
J
U
Q
JOB NO.
57006
L
SHEET NO.
C0.0
GENERALNOTES
2016 ROAD & BRIDGE STANDARDS
1. ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT VIRGINIA
DEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS AND STANDARDS.
2. PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR SHALL CONSULT THE ENGINEER AND VERIFY THE
APPROVAL OF THE PLANS BY ALL FEDERAL, STATE AND LOCAL AGENCIES.
3. LAND USE PERMITS (LUP-A) MUST BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF
TRANSPORTATION PRIOR TO BEGINNING ANY CONSTRUCTION WITHIN THE EXISTING STATE
MAINTAINED RIGHT OF WAY (INCLUDING ACCESS).
4. THE CONTRACTOR SHALL VERIFY THE ELEVATIONS OF ALL POINTS OF CONNECTION OR PROPOSED
WORK TO EXISTING CURBS, SANITARY LINES, WATERLINES, ETC, PRIOR TO CONSTRUCTION.
5. UPON DISCOVERY OF SOILS THAT ARE UNSUITABLE FOR FOUNDATIONS, SUBGRADES, OR OTHER
ROADWAY CONSTRUCTION PURPOSES, THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE
OWNER. THESE AREAS SHALL BE EXCAVATED BELOW PLAN GRADE AS DIRECTED BY THE OWNER,
BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED IN ACCORDANCE WITH CURRENT.
6. ALL STORM SEWER DESIGN AND CONSTRUCTION TO BE IN ACCORDANCE WITH VDOT I AND I LD-94 (D)
121.13.
7. ALL STORM SEWER PIPE SHALL BE REINFORCED TONGUE AND GROVE CONCRETE PIPE IN
ACCORDANCE WITH ASTM-C-76. PIPE WITHIN THE RIGHT OF WAY SHALL BE MINIMUM CLASS III OR
GREATER IN ACCORDANCE WITH CURRENT VDOT STANDARDS AND SPECIFICATIONS.
8. ALL CONCRETE SHALL BE A3-AE (AIR ENTRAINED 3,000 PSI), UNLESS OTHERWISE NOTED.
9. DESIGN CHANGES, SPECIFIED MATERIALS CHANGES AND/OR FIELD CHANGES FROM THE APPROVED
PLANS NEED TO BE RESUBMITTED TO THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. A
LETTER OF EXPLANATION SHALL ACCOMPANY THE REVISED PLANS AND/OR THE DRAINAGE
CALCULATIONS, WHICH MUST BE SUBMITTED AND APPROVED BY THE ENGINEER.
10. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES SHOWN
ON PLANS IN AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. CONTACT ENGINEER
IMMEDIATELY IF LOCATION OR ELEVATION IS DIFFERENT FROM THAT SHOWN ON PLAN. IF THERE
APPEARS TO BE A CONFLICT, AND/OR UPON DISCOVERY OF ANY UTILITY NOT SHOWN ON THIS PLAN,
CALL MISS UTILITY OF CENTRAL VIRGINIA AT 1-800-552-7001. THE OWNER SHALL BE RESPONSIBLE
FOR THE RELOCATION OF ANY UTILITY WITHIN EXISTING AND/OR PROPOSED RIGHT-OF-WAY
REQUIRED BY THE DEVELOPMENT.
11. THE INSTALLATION OF SEWER, WATER, AND GAS MAINS (INCLUDING SERVICE LATERALS AND
SLEEVES) SHALL BE COMPLETED PRIOR TO THE PLACEMENT OF AGGREGATE BASE COURSE.
12. ALBEMARLE COUNTY APPROVAL OF CONSTRUCTION PLANS DOES NOT PRECLUDE THE RIGHT TO
REQUIRE ADDITIONAL FACILITIES AS DEEMED NECESSARY.
13. A PRIME COAT SEAL BETWEEN THE AGGREGATE BASE AND BITUMINOUS CONCRETE WILL BE
REQUIRED AT THE RATE OF 0.30 GALLONS PER SQUARE YARD (REC-250 PRIME COAT) PER VDOT
STANDARDS AND SPECIFICATIONS.
14. THE SCHEDULING OF AGGREGATE BASE INSTALLATION AND SUBSEQUENT PAVING ACTIVITIES SHALL
ACCOMMODATE FORECAST WEATHER CONDITIONS PER SECTION 315 OF THE ROAD AND BRIDGE
SPECIFICATIONS.
15. THE OWNERS REPRESENTATIVE SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR
DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO
PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER FOR INSPECTION FOR THE
AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S).
16. A GEOTECHNICAL ENGINEER IS TO ASCERTAIN CAUSE AND CERTIFY RECOMMENDED METHOD OF
REPAIR FOR ALL PAVEMENT STRUCTURAL FAILURES PRIOR TO STATE ACCEPTANCE. (N/A)
17. ALL VEGETATION AND ORGANIC MATERIAL IS TO BE REMOVED FROM THE PROPOSED PAVEMENT
LIMITS PRIOR TO CONDITIONING OF THE SUBGRADE.
18. CERTIFICATION AND SOURCE OF MATERIALS ARE TO BE SUBMITTED TO THE OWNER FOR ALL
MATERIALS AND BE IN ACCORDANCE WITH THE ROAD AND BRIDGE SPECIFICATIONS, AND ROAD AND
BRIDGE STANDARDS.
19. ALL APPROACH GUTTERS TO SAG INLETS SHALL MAINTAIN A MINIMUM SLOPE OF 0.004 ft./ft.
20. ALL NEW HANDICAP ACCESSIBLE REQUIREMENTS ON -SITE AND WITHIN ALL NEW STRUCTURES SHALL
COMPLY WITH THE 2015 UNIFORM STATEWIDE BUILDING CODE, 2015 VIRGINIA CONSTRUCTION CODE,
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN AND ICC/ANSI A117.1-03.
21. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED.
22. ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL NOT HAVE A SURFACE SLOPE GREATER
THAN 1:48. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACE THEY SERVE.
23. ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE A PUBLIC NUISANCE AND NOT
OVER SIDEWALKS.
24. BUILDING OR STRUCTURES BUILT BEFORE JANUARY 1, 1985 MUST HAVE AN ASBESTOS SURVEY
PERFORMED IN ORDER TO APPLY FOR A PERMIT. ASBESTOS REMOVAL PERMITS ARE REQUIRED IF
POSITIVE FOR SUCH. CONTACT VDOLI FOR ADDITIONAL REQUIREMENTS AND PERMITS FOR
DEMOLITION PROJECTS.
ALBEMARLE COUNTY ENGINEERING GENERAL CONSTRUCTION
I\ln-rFc
1. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT OF WAY, INCLUDING
CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA
DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY
REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE
REQUIREMENTS OF THE PERMIT SHALL GOVERN.
2. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS
AND STANDARDS OF VDOT.
3. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE
APPROVED EROSION CONTROL PLAN AND MUST BE INSTALLED PRIOR TO ANY CLEARING,
GRADING OR OTHER CONSTRUCTION.
4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED.
5. THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTAL:VERTICAL). WHERE REASONABLY
OBTAINABLE, LESSER SLOPES OF 3:1 OR BETTER ARE TO BE ACHIEVED.
6. PAVED, RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION OF
THE COUNTY ENGINEER, OR DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A
DRAINAGE CHANNEL.
7. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM
TRAFFIC CONTROL DEVICES.
8. UNLESS OTHERWISE NOTED ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE - CLASS
III.
9. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS
FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926).
BLASTING NOTES
1. BLASTING SHALL NOT BE PERMITTED ON THIS PROJECT.
MANHOLE FRAME & COVER
ST'D. F&C-1 OR WF&C-1
GROUT IN PLACE
24"
M
FLAT SLAB TOP
MANHOLE FRAME & COVER STANDARD T-MH-2
i
N
' TAPER UPIT
T'D. T-MH-2
N
RISER UNIT
REQ'D WHEN D IS
ST'D R-1
GREATER THAN 4'-0"
PLUG LIFT HOLES
RISER UNIT
=
WITH RUBBER
0-RING JOINTS
ST'D. R-2, R-3
,
STOPPER AND
(ASTM C-443)
MORTAR
MANHOLE BAS
ST'D. B-
STEPS 12" TO 16"
O.C. STANDARD ST-1
STANDARD IS-1
OR B-2
SHAPING
D _
TOP OF SHAPING
FLEXIBLE CONNECTOR
SEE SHEET 2 OF 2
NOTES)
FOR DIMENSIONS NOT
SHOWN SEE VDOT ST'D.
B-1, B-2 & R-1
CONCRETE ENCASEMENT
TO EXTEND TO LIMITS
OF EXCAVATION
DIA OF
DROP PIPE
D-1 D-2
8" e"
D„ g„
12" 0"
15" 12"
18" 15"
24" & 18"
ABOVE
FORM BAS< cna
90' BEND
A
L
CLASS A3 CONCRETE
PIPE MATERIALS TO MATCH
MAN LINE (D.I., C.L. OR PVC, ETC.) r
CAST IRON 90' BENDS
BASE STANDARD B-10R B-2-�
PRECAST CONCRETE MANHOLE
NOTES:
1. WHEN HEIGHT H EXCEEDS 12' A MINIMUM NOMINAL DIAMETER D OF
THE BASE UNIT SHALL BE 5' WITH A SECTION HEIGHT OF
WAND A STANDARD RISER UNIT R-2 OR R-3 SHALL BE REQUIRED.
2. FLAT SLAB TOP STANDARD T-MH-2 SHALL ONLY BE ALLOWED
ON SHALLOW MANHOLES.
3. STEPS SHALL BE ENCASED IN CORROSION RESISTANT
RUBBER OR OTHER MATERIAL APPROVED BY THE ENGINEER.
4. STEPS SHALL BE OMITTED WHEN SPECIFIED IN THE PLANS.
5. SEE STANDARD SHEET NUMBER 106.07, VOLUME I, FOR ADDITIONAL MANHOLE
DETAILS.
SPECIFICATION
REFERENCE SANITARY SEWER MANHOLE
VIRGINIA DEPARTMENT OF TRANSPORTATION
SMH-1
J
o
U
ROAD AND BRIDGE TANDARDS
SHEET 2 OF 2 REVISION DATE
1411.02
ALL JOINTS SHALL BE RESTRAINED BY
RETAINER GLANDS OR THREADED RODS (GALVA
FORCE MAIN DISCHARGE
TYPE 1
FILLER PIECE
(ONLY IF NEEDED)
TOPS
22 1/2'
L. R. 45'
ALL JOINTS SHALL BE RESTRAINED BY
RETAINER GLANDS OR THREADED RODS (GALV.)
FORCE MAIN DISCHARGE
TYPE 2
INTERNAL EXPANSION BAND
FLEXIBLE CONNECTION
STAINLESS STEEL CLAMP
PRECAST MANHOLE STANDARD
B-1 OR B-2.
FLEXIBLE CONNECTION
AND SPECIFICATIONS.
SMH-1
A
SECTION B-B
DAM %z D-1
DIAMETER MAX.
TEE
ST'D. SMH-1
�^�•
MANHOLE
(FOR 0-2 OF 12" I& LESS)
36"
(FOR D-2 OF 15" & 15")
SECTION A -A
SANITARY DROP CONNECTION
SANITARY SEWER MANHOLE
WATER AND SANITARY SEWER FACILITIES
VIRGINIA DEPARTMENT OF TRANSPORTATION
ROAD AND BRIDGE STANDARDS
REVISION DATE SHEET 1 OF 2
14it.ot
FILLER PIECE
(ONLY IF NEEDED)
SPECIFICATION
REFERENCE
^� E
0
0 U
N 6
N C
¢ o
> E
w a E
ui
Q ULL 3
w o n
m..
Q J U w
W J -uj
rr
W N N
7
Z y �
�x
9-1V)�
o¢ �v
U N N
= U >
H ¢
c 0)
rn
O N
v�
a�
W J
CL
O
oc
f
w
Q
DATE
311512023
DRAWN BY
S. KIRBY
DESIGNED BY
S. KIRBY
CHECKED BY
J. SHOWALTER I
SCALE
N/A
U
I�
>
Q
,L/u
v,
/ n
=J
LU
_J
06
zQC/)
oZLu
Q
O
Q
z
L
H
JOB NO.
57006
SHEET NO.
C1.0
OPENIGRASSAREA \ I L I DEMOLITION HATCH LEGEND
\ I I I I I \ I I I I I REMOVE SANITARY SEWER
REMOVE SEPTIC TANK
FFE=450.17' / / l l I I I I I GZ FFE=450. 17'
DOUBLE DOORS / / / / / / I / II \\ I I DOUBLE DOORS
f
b
REMOVE AN PATCH
HOLE IN EXI TING
TOTANKS.RESERVE
MANHOLE./
REMOVE \
MHS S I MHS
TOP- 42.68 C ACCESS \ \ / / / / / MHS ,TOP- 42 6g C ACCESS \
/ / / / I EXISTING MANHOLES AND � \
T P=443.25' ' INV. BQT=430.81' \ \ 449� / / , TANKS ARE TO BE REMOVED \ \
.O / I c / / � 7,OP=443.25' INV BQT=430.81' \ ,
INV IN=136.90'8"VC / S , \ \ I / /' / / / INV 1N=436.90'8"VC / S PER SEPTIC PLANS. \ \
/ - / INV INV. OUT%436.70'8"VC OUTy436.70'8"VC / / I MHS-SEPTIC ACCESS \ � / / / / � / f MHREMOVE
EPTICACCESS \
I TOP=441.88' \ / / / / , I TOP=441.88'
0^ I INV. BOT=430.83' /� -pAa / / / / / / / /' REMOVE I INV BOT=430.83'
MHS -SEPTIC ACCESS ' S - MHS - SEPTIC ACCESS ' S TOP=442f98- \ ' / / / - TOP=442,05-
�^q INV. BOT=460.81' / ' / / / INV BOT=4d0.81' ^
MHS -SEPTIC ACCESS // ' / ' ' ' MHS - SEPTRE MOSE REMOVE
TOP=441.38' SS MHS - SEPTt TANK ACCESS / \ / / dd�' TOP=441.38' O ' —MHS - SEPTI\C TANK ACCESS
TOP=44.1.54 \ / / TOP=441.34' \
INV. BOT=430.45' / ' INV. B0T=430.45'
TANKBOTTOM=4�32.01' / \ i ' -TANK BOTTOM=432.0V
APPROXIMATE LOCATION OF \ / 1y / ' APPROXIMATE COCAT/ON OF \ \
/ REMOVE
EXISTINGNATERLINE EXISTINGNATRLINE
.
C.
4.5x 4. 1
4.5 x 4.V
44r ' \ , / ' -441. ' - REMOVE PER SEPTIC \
' PLANS
OPENIGRASSAREA / ' \\ OPENIGRASSAREA
/
(PART OF) TMP 101-56A ' / (PART OF) TMP 101-56A
TY Of ALBEMARLE SCHOOL�BOARD — — _ _ TY 9)�_ALBEMARLE SCHOOL�B"OARD
/ DB. 507, PG. 626 / \ / OB. 507, PG. 626 / \
/ ZONED: RA i \ \ / ZONED: RA
/
%440� \ \ \ / / %440- \ \
/ —�— --—————— — — — — ——
`- -— - -- _ - -- --————— — — — — ——
\
-441 -
- - - - - \ / ' - - - - - \
-'\-_ - \-----------
438' _ - - ' - - - - - - - \ _ \ \ I / I / - 438- \ \ \
I - _ - - - - - - - - - \ \ \ \ .CONC. CONC.
-437
- 4366.5'x 6.9\ \ / - \ I ,436 - - 6.5'x 6.A \\ /
,- \ ---_-
T �
1 1
L
.433 -433 - '
1
432
M - /`\ \\ \ \\ \\ \ I M
c0 / / / v \ \ 00
---431------ / // \ \\ \\\ \ \\ \ \� Z --431- / // \ \\ \ \\\\ \ \\ \ \ `� Z
U
L
U
SCALE 1"=30' /' / / / `\ \ SCALE 1"=30'
/ / \
-
--------------
-- - - - -/' // ,' 426._ --\ 0 30' 60'---------------------'' / -- 426 0 30' 60'
EXISTING CONDITIONS
DEMOLITION PLAN
I
I
I
I
I
I
^� E
0
N OV
N c
> E
w v E
ui
U. ¢" 3
a
0 LL
o n
0 O L M
Q J U w
w J — uj
rr
(D W N N
v
Z y �
x
oQ �v
U 0
= U >
O N
04
a�
W J
N
z
0
f
w
a
DATE
311512023
DRAWN BY
S. KIRBY
DESIGNED BY
S. KIRBY
CHECKED BY
J. SHOWALTER
SCALE
ill =30'
^a
LL
O
U
�_-
0
W
a >
2E
I n
/
}L
cl
IV
v /
Z
O
06
C
G
U
co
zQo
W
Z
O
Lu
J
co
a
Q
o
r n
v
v !
X
W
JOB NO.
57006
SHEET NO.
C2.0
L
/
Q / /
_ 441-
LIMITS OF DISTURBANCE = 7,500 SF
U) "IN z � - - j
APPROXIMATE LOCATION
EXISTINGyI/ATERLINE.
\ _
-444 - ? £ 5 \ I OPEN / GRASS AREA
- � / ' z cm/ FORCE MAIN ` \
/ AA oo - - \ I I / 3.5' MIN COVER \ -
/ l (PART OF) TMP 101-56A
/ \ I
/ - - - - COUNTY qP-ALBEMARLE SCHOOL/BOARD \ — —
/ / DB. 507, PG. 626 / \ I I I \ \
ZONED: RA /'
�qqp- 7' \
SO INLET \ l pT
TOP=443.17' S-
1NV. OUT=438.8' 12" RCP / c'o2o
r�� / 224.74' OF \
8" SDR 35 z I I \ \
/ \ \
FORCE MAIN TO HAVE 18" OFSEPARATION \ -441 -\
WITH EXISTING WATER LINE. CONTRACTOR
TO HAVE SCHOOL MARK AND FIELD VERIFY. \ \
\ I
438-
P� I Q I I I\
SD INLET
TOP=436.10'
INV. 1N=432.19' 12"
INV OUT=431.42' 12" RCP _ _ _ \ \ \ r
_ - - 143t I I I \
TOP=434 45' \ \ \ 1 \ \
I IN=424.34'rPVC
/i \ti SANITARY SEWER PUMP \ \ \ \ \ \
407 PER SEPTIC Pt QNS.
O O
ILET8.32'_____@p l \\ 1
4\- -- - - - -
RCP It B� �\ \ \ /�
I 2 \ O c\ \ \ \ \ / / / / TOP=431.88' 1 I \ w \ \ 1
RCP _ _ \ N(OOD POTS 1 N \ \ \ \ \
CONTRACTOR TO PROTECT
SD INLET AND PRESERVE CURB- BEfe1CHES\ \ \
SOP=426.051 I
It 426, / IMV. OUT=42$.6P8"VC I .432
/ ® / I
III // VVp I
AREA TO BE USED AS —
PAVED WASH RACKS — -431
0 iU \\ \ \\ /� \\ \\ NE'EDEDWITHIN TIMES /
ALLOWED BY SCHOOLS / / / -
OUTSIDE OF NORMAL
PICKUPANDDROP OF -430-
ASPHALT
ENTRANC2= \ /l \ \ ` .429 - - - - 426
23
�1\ — _ _ — — — _ — — — — — — — — — — — — —
— 428-
It
I \ EP
I
427-
SD lNL1T
\\ \\ —----_--- — _
\ II CURB 70 ------ - -425
\\\
\ TOP=4201J9�
INV. IN (N0RTH)=4,1735' 12" RCP
\ \ INV IN (WEST)=417.&'42" RCP 7/ ` \ \ \ \ ` — — — — — — — _426 —
IP \\\ `-IN�OUT (SE=41705' 18"l3CR
425_ qp4--
IRKER \
- - - -423- _ _ - - - - - - - - - - - - - - - - - - - - - - - - - - _423 -
_y
b10
\
CORIf DRILL HOLE FOR NEW
PIPE bUT AND REMOVE AND
/ r I REPI ACE MANHOLE SHAPING
TO MATCH. —
/
RESTORE EXISTING GRADE. BACKFILLMHS \
WITH CLEAN STRUCTURAL FILL OR \
/ 449 / / / / / / / T,OP=443.25' CRUSHED STONE. TOP 1' TO BE TOP
INV. IN=¢36.90'8"VC I TOPSOIL. \
INV OUTy436.70'8"VC-
L/ //
SCALE 1 "=20'
0 20' 40'
^� E
0
0 0
N 6
N
C
> E
a E
w
ui
<. Z 3
LL
LL 2
O
0 L M
Q J U w
Z
w .j —uj
O
N
d
WN 7
FF
F =
N Q
U
i u_
w
S ry
U
Z
O
= ko
H c u'
o,
N
i
a�
W J
Isi
DATE
311512023
DRAWN BY
S. KIRBY
•
DESIGNED BY
•
S. KIRBY
•
CHECKED BY
J. SHOWALTER
•
SCALE
ill =20'
•
N
Z
0
f
U
I..L
W
>
Z
z
O
—I
0-
Z
W
Q
O
O
L
m
Q
J
a
J
JOB NO.
57006
SHEET NO.
C3.0
L
r-
S:\103\57006-Walton MS Septic Project\DWG\Sheet\CD\57006-103-C4.0-SSPR.dwg I Plotted on 3/15/2023 4:48 PM I by Scott Kirby
m
A
O A
N
+ rr
+ k
0
0
� � U
ZAAP
W A O
A m N OO
rn Wa'o
0 0 0
D
z
D+
0
=moo
in
m O 'G
� N VJ
0Dm
Dr
r
mm m
v, O
T ,
TI N
N +
O�
0
N
m CCOD
CO ZCA�N
1' +
A O A A
O A v
N O A
00
W �
+ m
o
oi
n
D
Z
A
+ CA
rr
O
O CT
X
0
n
F
m
a)
0
D
mo
• • 0 0 THIS DRAWING PREPARED AT THE
CHARLOTTESVILLE OFFICE
• • 608 Preston Avenue, Suite 200 1 Charlottesville, VA 22903
TIMMONS ROUP TEL 434.295.5624 FAX 434.295.8317 www.timmons.com
_ cn WA LTO N M S SEPTIC = N DATE REVISION DESCRIPTION
cn 2 cn rn o
Z q Z ALBEMARLE COUNTY VA p D n o A m A z Nj
m
ob
SANITARY SEWER PROFILE Z A W w
�
-A+
N
N
W
W
A
O
CT
O
CT
O
CT
O
443.2
��11Jn
Om�p
/
��mm
�c�icoo
r/
441.1
= Dz_�
L7 -
=�0
Omm
�cyN
� �Z
0
moT
n�oia
v�a�,.
�J
=mom
�Dm
�
439.5
OTZDZ
4377
O
/
D�
�
n
/
�zo�
m�o�
W
/
t7 n n Z
435.4
Z O T �
Z
�rOT7
cnOnr
�mD-Dim
AmO�
Z
ZD��
m�Do
m�
m��
O�Oo
=no
J
CO�°zm
�Zo
N
N
W
W
A
O
CT
O
N
O
N
O
These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not
limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.