HomeMy WebLinkAboutARB201500031 ChecklistSIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business
ARB 201500031, Physical Therapy at ACAC
03 -20 -15
REF
CHECKLIST ITEM
NOTES
TYPE
•
9.b
For internally illuminated signs, channel lettering
OK — individual letters — meets CSC
(mounted on a raceway or individual letters) is preferred to
cabinet signs.
•
5.b
When channel letters cannot be adequately accommodated,
N/A
internally illuminated cabinet signs may be considered.
•
6
Reader boards are discouraged.
None proposed
MATERIALS
•
4.c
Materials used in the sign should complement the building
Issue: CSC require metal — PVC proposed
being served by the sign.
COLOR
•
4.e
Color for raceway- mounted channel letters, the raceway
N/A
shall match the wall color.
Sign colors must be harmonious with each other.
Issue: CSC require bronze — black proposed
Sign colors must not clash with the site, when viewed in
OK
daylight and at night.
Overly intense color, (such as dayglo or fluorescent
None proposed
colors), are prohibited.
Use of three colors or less (black and white considered as
OK— 1
colors)
Additional colors may be approved if they contribute to the
sign balance /unity.
SIZE, SCALE, PROPORTION, AND LOCATION
•
4.b
Signs may not exceed the size, height and setback
OK
requirements as outlined in Section 4.15 of the Albemarle
County Zoning Ordinance (unless sign has a variance).
REF
CHECKLIST ITEM
NOTES
•
Appendix
A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall
OK
A.A
area is a good working proportioning system for placing a
sign.
•
Appendix
Color, form, surface pattern, shape, and disposition of
OK
A.A.4
elements and openings in an architectural design can affect
our perception of scale and can impact the appearance of a
sign on a building.
•
9.d
The wall sign's size must coordinate with the architectural
OK
element's size.
• In approved sign band per CSC
• Flat cornice: only 12" tall while letters 11.2" tall
— OK due to limited visibility (angular
orientation to & distance from EC & 21.75"
beam height). 21.75" height appears to be sign
band height as viewed from EC.
The sign should not over -crowd the architectural element,
OK
the wall, or the sign area.
Buildings and building elements should not be used as
OK
billboards.
•
9.a
Wall signs must integrate with the building's architecture.
OK
The sign placement should not obscure architectural
OK
features or details, (such as cornices, windows, columns,
pilasters and paneling).
•
9.d
An appropriate height for channel letters in a 30" high sign
N/A
band is 18 ".
This allows 6" of unoccupied space above and below the
letters.
4" of clear space above, below, and to the sides of a
channel letter sign is considered a minimum, with larger
REF
CHECKLIST ITEM
NOTES
clearances required for larger sign bands.
Degree of visibility, the distance from the Entrance
Corridor, and the architectural design of the building /area
will determine sign size, placement, and proportions.
X
4.d
Lettering should be in proportion (font size and typeface
style) to the sign and the building.
OK
Use of three typefaces or less.
OK— 1
Additional typefaces may be approved if they contribute to
a balanced /legible /unified sign design.
N/A
X
9. e. iv
The width of the outline must be in proportion to the width
of the letter.
None proposed
An outline width of 1/8" has been found to be an
appropriate sign dimension.
TRADEMARKS, CORPORATE LOGOS AND GRAPHICS
X
4.f
The ARB may require that the color and scale of standard
templates for trademarks, service marks, corporate logos
and graphics be modified.
None proposed
When used, trademarks, service marks, corporate logos
and /or graphics should be incorporated as an integral part
of the overall sign.
X
S.a
External (or no) illumination is preferred for approved
graphics /logos;
X
S.b
internal illumination may be considered for approval on a
case -by -case basis.
LIGHTING
X
9.e.i
External (or no) illumination is preferred for wall signs.
Issue: needs to be noted on drawing that sign is to be
non - illuminated
REF
CHECKLIST ITEM
NOTES
X
5.f
Any internal illumination is considered to contribute to
N/A
visual clutter and will be limited.
X
5.c
Internal illumination design approval will be evaluated on
size, balance, complexity, and distance from the Entrance
Corridor.
X
9. e. iv
The backgrounds of such cabinet signs must be made
None proposed
opaque (zero light transmission).
X
5.e
External illumination should be shielded and not create
glare.
All external light sources shall be white.
X
9. ii
Sign lighting (external) should be shielded so that it
None proposed
illuminates only face of the sign and does not shine beyond
the edge of the sign.
X
9. iii
Channel letters with translucent faces must have no light
None proposed
spilling outward from the top, bottom, sides or back.
Faces and returns of channel letters shall be opaque when
back -lit (halo -lit).
X
9. iv
Cabinet signs shall have a non - illuminated background, or
None proposed
an opaque (zero light transmission) background.
Cabinet signs shall be constructed such that no light spills
outward from the top, bottom, sides or back.
X
5.g
All illumination shall be non - blinking.
None proposed
X
5.h
An exposed light source that forms the body of a sign,
None proposed
(such as exposed neon signs), shall not be used in the
Entrance Corridors.
ARB ACTIONS
X
If LED lighting is proposed the sign drawing must state
N/A
The level of illumination provided by the LED lights will
not exceed the illumination produced by a single stroke of
30 milliamp (ma) neon.
REF
CHECKLIST ITEM
NOTES
X
Red acrylic #2283 has been determined to be an
No red proposed
inappropriate color for signs.
Pantone color match for 2283 is 485C.
Red #2793 has been approved as an acceptable substitute.
Pantone color match for 2793 is 187C.
X
ARB
Visual clutter resulting from adjacency, for example at the
None proposed
Action
Hardee's locations, is a reasonable basis for not allowing
Memo:
illumination of the graphic.
5/7/12
RESUBMITTAL REVIEW CHECKLIST
PROJECT #/NAME: ARB 2015 -31, PT @ ACAC
03 -25 -2015
ARB COMMENT
NOTES
X
Approved ARB Comprehensive Sign Criteria for this
location require metal, bronze color sign letters. Your
proposal is for PVC, black color letters. Revise the sign
drawing to show metal, bronze color letters.
OK — revised to indicate bronze color letters
X
Revise the sign drawing to include the following note:
"This sign is to be non - illuminated."
OK — note added to drawing
ARB COMPREHENSIVE SIGN CRITERIA 11 -15 -2010
(updated 2 -15 -2011, reformatted 4 -28 -2011)
ARB- 2006 -78 and ARB- 2010 -96: Shoppes at Clover Lawn
Tax Map 56F1, Parcels 1 and 2 (previously Tax Map 56, Parcels 107,107A and 107A1)
Tips for using these tables:
1. Begin by choosing one of the locations approved for signs on the Clover Lawn buildings. Each
individual table outlines the design criteria for a particular location on the buildings.
2. Once you identify an approved location, proceed to "sign type" within that table. That information
identifies the type of sign that is allowed in that particular location.
3. Then identify the corresponding size limitations.
4. Then identify the corresponding requirements for color, mounting, logos, illumination, etc.
CLOVER LAWN SIGNS #1— First Floor
SIGN LOCATION
Within the porch architrave on the first floor, or above the first floor
storefront cornice where no porch exists.
SIGN TYPE
Individually cut letters
SIZE LIMITATIONS
Letter height max 15"
Logo height not to exceed 18"
LETTER COLOR
Bronze
MOUNTING DETAILS
Individually mounted
LOGOS
Logos are allowed
Logo colors are unlimited
The logo shape must be fully articulated
ILLUMINATION DETAILS
Backlit — Halo lighting for letters
Colored logos may not be internally illuminated but they may be halo lit
Bronze logos may be halo lit
LETTER TYPE/FONT
Not limited
MATERIALS
Not limited
NOTES
Box signs with name or logo printed on a back -lit sign face are not
allowed. Letters and logos must be cut to the outline of the letter /logo.
F, `TWV T 1 11V \C RT R 1 IVC3� i
Sign #1, left: An individually cut bronze letter sign with a bronze logo in a porch architrave on the first floor.
Sign #1, right: An individually cut bronze letter sign above the first floor storefront cornice.
CLOVER LAWN SIGNS #2 — First Floor
LOCATION
The easternmost and westernmost tenant spaces of the first floor, on
the wall under the porch overhang, spanning the transom window,
flush with the wall
SIGN TYPE
Cabinet or logo box
SIZE LIMITATIONS
Letter height maximum 15"
logo height maximum 24"
LETTER COLOR
Unlimited
TRIM CAP/RETURN
COLOR
Unlimited
BACKGROUND COLORS
Unlimited
MOUNTING DETAILS
Mounted on wall, spanning the transom window
LOGOS
Logos allowed
Logo colors: no limit, but consistent with standard corporate logos
ILLUMINATION DETAILS
External or halo lighting; no opaque requirement
LETTER TYPEXONT
Not limited
MATERIALS
Not limited
Sign #2: Arrow shows the transom location of the easternmost first floor tenant space under the porch.
CLOVER LAWN SIGNS #3 — First Floor
LOCATION
To the east of the storefront entrances at the first floor, under the
porches
SIGN TYPE
Blade (panel)
SIZE LIMITATIONS
As per zoning
LETTER COLOR
Unlimited
BACKGROUND COLORS
Unlimited
MOUNTING DETAILS
Hung from brackets attached to the wall under the porch
LOGOS
Not limited
ILLUMINATION DETAILS
External
LETTER TYPEXONT
Not limited
MATERIALS
Not limited
Sign 43: A blade sign hung to the east of a storefront entrance under a porch on the first floor.
CLOVER LAWN SIGNS #4 — Second Floor
LOCATION
Centered in gables of the second floor as illustrated on the building
elevations dated 10/27/10
SIGN TYPE
Individually cut letters
SIZE LIMITATIONS
Letter height maximum 15"
LETTER COLOR
Bronze
MOUNTING DETAILS
Direct to wall
LOGOS
Allowed if integrated with the text. Box signs with a name or logo
printed on a back -lit sign face are not allowed. Letters and logos must be
cut to the outline of the letter /logo.
ILLUMINATION DETAILS
Backlit — Halo lighting
LETTER TYPEXONT
Not limited
MATERIALS
Metal
Sign 44: A bronze individually cut letter sign centered in a second floor gable.
CLOVER LAWN SIGNS #5 — Side Elevations
LOCATION
Side elevations
SIGN TYPE
Individually cut letters OK
SIZE LIMITATIONS
Signs must be compatible in proportion with other signs and the overall
building. OK
LETTER COLOR
Bronze Issue: Black
MOUNTING DETAILS
Direct to wall OK
LOGOS
Logos /graphics must be incorporated as an integral part of the overall
sign. None
ILLUMINATION DETAILS
No illumination allowed Issue: Non - illumination needs to be note on
drawing
LETTER TYPEXONT
Not limited
MATERIALS
Metal Issue: PVC
Sign 45: A bronze individually cut letter sign in the porch architrave of a side elevation.